AAAAAA, AAAAAA, AAAAAA, AAAAAA

Size: px
Start display at page:

Download "AAAAAA, AAAAAA, AAAAAA, AAAAAA"

Transcription

1 Owner s Manual Regal 6 Dental Procedure Table with Ultima 250 Dental Unit! Ergonomic Access to Tools Make Dental Work Easier & Faster! Three-way Air / Water / Mist Syringe! Handpieces Activate Automatically When Picked Up! Stainless Steel Cabinetry for Beauty, Easy Care & Long Life Model Numbers: AAAAAA, AAAAAA, AAAAAA, AAAAAA SSCI Wheeling, IL (800) Form No /08

2 Copyright 2008 by Suburban Surgical Co., Inc. All rights reserved. No part of this document may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system without written permission. Inquiries should be addressed to Suburban Surgical Co., Inc. Wheeling, Illinois 60090, USA

3 Table of Contents Owner s Manual - Regal 6 Dental-Procedure Table with Ultima 250 Dental Unit Chapter 1 - General Information... 1 Introduction... 1 Regal 6 Recessed End Dental Procedure Table... 1 Ultima 250 Dental Unit... 1 About this Manual... 2 Information & Safety Notices... 2 Notes... 2 CAUTIONS... 2 Safety... 2 Models... 4 Accessories... 4 Care & Cleaning of Stainless Steel... 5 Introduction... 5 Cleaning & Cleansers... 5 Deodorizing Agents, Disinfectants, & Sanitizers... 5 Effect on Warranty... 6 Cleaning Requirements... 6 Contact Information... 6 Suburban Surgical Company, Inc Ultima Dental Systems... 7 Warranty... 7 Chapter 2 - Installation & Setup... 9 General... 9 Unpacking & Inspection... 9 Lifting the Dental Table... 9 Installation - Regal 6 Dental Procedure Table Preparation Installation Procedure Overview Tools & Supplies Required Installation Sequence Determine the Table Location Open the Wall Install the Piping for the Faucet & Drain & Electrical Wiring Open Holes in the Table Wall(s) for Piping & Wiring Finish the Wall Place the Table in Position Connect the Drain Install the Faucets & Sprayer Mount the Dental Unit to the Swing Arm Finish the Job Testing the Installation Form No April, 2008 i

4 Table of Contents Chapter 3 - Use & Care of the Regal 6 Table Using Your Regal 6 Table Using the Drawers Opening & Closing the Drawers Removing & Replacing a Drawer Using the Cabinet Doors Opening & Closing the Cabinet Door Hinges - Overview Removing a Cabinet Door Installing a Cabinet Door Adjusting the Door Left-to-Right Adjusting the Door In & Out Using Prep Procedure Racks Overview Removing & Installing a Rack Keeping Your Regal 6 Table Clean Introduction Stainless Steel Cleaning Procedures Chapter 4 - Use & Care of the Dental Unit Initial Set-up for Your Dental Unit Operating Your Ultima 250 Dental Unit Water Controls General On/Off Switch Water Volume Control Knob Bottle Selector Switch Handpiece Holders Adjusting Handpiece Air Pressures Red Air Line White Air Line Blue Air Line Recommended Handpiece Air Pressures Adjusting Handpiece Air Pressures Refilling the Water Bottles Using the Three-Way Syringe Checking Compressor Gauges Correct Settings Adjusting Air Pressure Accessing the Compressor Using the Foot Controller Accessing the Dental Unit Interior Connecting an Ultrasonic Scaler Maintaining Your Dental 250 Dental Unit Cleaning Procedure Routine Maintenance ii SSCI - Suburban Surgical Company, Inc.

5 Owner s Manual - Regal 6 Dental-Procedure Table with Ultima 250 Dental Unit Maintenance Schedule Routine Maintenance Procedures Flush Water Lines After Using Chlorhexadine Oil Handpieces Check Oil Level in Compressor Top Up Oil Level in Compressor Drain Compressor Holding Tank Removing, Cleaning & Replacing the Pickup Bottle Cleaning the Pickup Bottle Replacing the Pickup Bottle Drain Oil From Compressor and Replace With New Oil General Procedure Compressor Safety Tips Cleaning Your Ultima Introduction Cleaning Procedure Chapter 5 - Parts Replacement, Regal Replacement Parts General Information Parts Ordering Procedure Returning the Dental Procedure Table for Repairs RMA Numbers Packing & Shipment Parts Replacement Procedures Cabinet Door Overview Tool Required Procedure Door Hinge Overview Tool Required Procedure Door Hinge Mounting Plate Overview Tool Required Procedure Drawer Overview Procedure Drop-in Tub Overview Tools Required Procedure Form No April, 2008 iii

6 Table of Contents Dental Procedure Rack (Flat Rack Standard, Other Racks Optional) Overview Procedure Removable Bathing Rack (Optional) Overview Procedure Chapter 6 - Parts Replacement, Ultima Replacement Parts Parts Ordering Procedure Returning the Dental Unit or Compressor for Repairs Chapter 7 - Troubleshooting General Problems No Water Polisher Problems Insufficient Air Pressure to Handpieces Compressor Will Not Run Compressor Does Not Turn Off Compressor Runs But Does Not Supply Air Air Leak Compressor Makes a Rattling Noise During Operation Compressor Oil Appears Milky Air Tank Does Not Hold Pressure When Compressor Is Not Running No Air Pressure Shown on Regulator Gauge iv SSCI - Suburban Surgical Company, Inc.

7 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 1 - General Information Introduction Regal 6 Recessed End Dental Procedure Table SSCI s Regal 6 Dental Procedure Tables are constructed of dieformed, stainless steel shaped on a CNC machine for accuracy. All panels are engineered for tight fitting joints, and both welded and mechanically fastened to make a solid, sturdy cabinet. All cabinet interiors are stainless steel making them impervious to moisture and odors. Drawer fronts are double-wall stainless steel, with full-width pulls integrated into the design. Welded one-piece drawer bodies are stainless steel with telescoping slides that allow the drawers to open and close easily even with heavy loads. Doors are double-wall stainless steel with integral full-width pulls. Doors feature invisible positive-action hinges that hold the doors open or closed as needed. 3D micro-adjustment ensures accurate door alignment. Ultima 250 Dental Unit The Ultima 250 Dental Unit is a stylish, three-handpiece automatic control head with a three-way syringe (water, air & mist). The variable-speed foot controller allows you to choose the desired speed for each procedure. The unit uses two oneliter bottles allowing the use of chlorhexadine in one bottle and distilled water in the other. This allows chlorhexadine to be easily flushed from the system. The air lines are color-coded to distinguish between high and low-speed air lines and accessories. Form No April,

8 Chapter 1 - General Information An optional venturi suction system can be ordered with the unit or added to any existing Ultima 250 Dental Unit. The Ultima 250 can be ordered with either a single-head or a dual-head surge compressor. Busy practices will find that a dual-head compressor will allow them to work for extended periods without overheating the compressor. About this Manual Every attempt has been made to insure that the information in this manual is correct and complete. SSCI, however, always welcomes our customer s suggestions for improvements to our products and associated publications. Information & Safety Notices Notes In this manual you will find important information under the headings Note: and CAUTION:. Under Note: headings, you will be given additional information pertinent to the subject discussed in that paragraph or step. Example: Note: Both bottles may contain distilled water or one may contain distilled water and the other chlorhexadine. CAUTIONS Under CAUTION: headings, you will be alerted to potentially hazardous conditions which, if ignored or mishandled, could result in injury to yourself, or damage to the equipment. Example: CAUTION: Never exceed 80 psi going into the dental unit. Safety CAUTION: Unpacking and installing the table is not difficult. The table is heavy, however, and handling it can be awkward for one person. We recommend that unpacking and installation be done by at least two people. CAUTION: The warranty for this product is void if the care and cleaning instructions provided in this manual are not followed. 2 SSCI - Suburban Surgical Company, Inc.

9 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit CAUTION: Use only distilled water in the dental unit. NEVER use tap water. CAUTION: Never exceed 80 psi air pressure going into the dental unit. CAUTION: When using chlorhexadine, flush the lines with distilled water for 30 seconds to one minute after finishing working. Failure to flush the lines can allow the chlorhexadine to dry and form particles that can clog the water lines and damage or destroy your handpiece. CAUTION: Any attempt to service your compressor by removing the compressor shell or terminal box cover, tampering with the pressure switch setting and/or grounding plug will VOID your warranty and may make the compressor unsafe to use. CAUTION: Use ONLY Silent-Surge Compressor Oil. Using any other type of oil will VOID your warrantee. Form No April,

10 Chapter 1 - General Information Models Table 1 lists the part numbers of the various Ultima 250 models and the available accessories. Ultima 250 Dental Unit SSCI Part Number Description AAAAAA Unit with Accessory Air Lin e AAAAAA Unit with Piezo Scaler AAAAAA AAAAAA Unit with Fiber Optic High-speed Air Line Unit with both Piezo Scaler & Fiber Optic High-speed Air Line Ultima Dental Venturi Suction System AAAAAA Venturi Suction System Compressor AAAAAA Single-head, Silent Surge Compressor - 1/2 hp AAAAAA Dual-head, Silent Surge Compressor - 1 hp Table 1. Part Numbers - Ultima 250 & Accessories Accessories Dental Procedure Table A variety of accessories is available for Regal 6 Dental Procedure Table to increase your convenience and efficiency. Refer to your current SSCI product catalog for pictures, descriptions, and part numbers.! Pull-out Trays! V Prep Procedure Racks! Flat Prep Procedure Racks! Solid Removable Tops! Tub Floor Removable Bathing Racks Dental Unit SSCI provides two accessories for the Ultima 250 Dental Unit. Refer to Table 1 for Part Numbers.! Dental Venturi Suction System! Compressor 4 SSCI - Suburban Surgical Company, Inc.

11 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Care & Cleaning of Stainless Steel Introduction Stainless steel is steel alloyed with chromium to make it highly resistant to stain, rust, and corrosion. Note: This does NOT mean that stainless steel will never rust or corrode. Science has not yet developed a steel which is completely stainless or corrosion PROOF. The type of stainless steel and finish selected by SSCI for this product is the best available for the intended use. Cleaning & Cleansers The basic rule of thumb is to use the mildest cleaning agent that will do the job effectively. After cleaning, always rinse thoroughly with clear water, and dry completely. Frequent cleaning will prolong the service life of stainless steel equipment and will help maintain a bright, pleasing appearance. Ordinary deposits of waste and fluids can usually be removed with soap and water. More stubborn deposits or tightly adhering debris may require harder scrubbing and possibly the use of commercial cleaning products acceptable for use on metal surfaces. When using any cleaning agent, rub in the direction of the polish lines or grain of the metal. For high luster finishes, clean soft cloths or pads should be used. If especially rough cleaning is necessary, use stainless steel wool, nylon, or plastic scrubbers. Test these scrubbers in an inconspicuous area first to be sure they do not mar or scratch the stainless steel finish. Minor scale build-up and some hard water spotting may be removed by washing with vinegar, followed by a neutralizing rinse with clear water and a thorough drying with a soft cloth. For heavy deposits of scale, 5% oxalic acid (use warm), 5-15% sulfamic acid, or 5-10% phosphoric acid may be used. Always follow with a neutralizing rinse of clean water and a thorough drying. Deodorizing Agents, Disinfectants, & Sanitizers The large selection of brands and combinations of chemicals available for deodorizing, disinfecting, and sanitizing is staggering. Select one or more agents for use in your facility only after weighing all the benefits claimed by each product. Often this choice is made without adequate consideration of the effects these agents may produce on equipment or furnishings. Form No April,

12 Chapter 1 - General Information CAUTION: Before selecting a chemical to employ in your facility, review label statements regarding use with metals (stainless steel). Always consult the chemical supplier if there are any doubts. Avoid prolonged use of chlorides (such as chlorine bleach), bromides, iodides, and thiocyanates on stainless steel surfaces as these chemicals will cause pitting, corrosion, and metal discoloration. Allowing salty solutions to evaporate and dry on stainless steel may also contribute to corrosive conditions. In summary, select chemical deodorizers, disinfectants, and/or sanitizers only after weighing all possible benefits and known adverse effects. Effect on Warranty The warranty for this product is void if the care and cleaning instructions provided in this manual are not followed. Cleaning Requirements Clean the Regal 6 Table and the Ultima 250 Dental Unit exactly in accordance with the cleaning instructions provided in Chapters 3 and 4 of this manual. Failure to follow these instructions can void your warranty. Contact Information Suburban Surgical Company, Inc. Contact SSCI Customer Service by mail, telephone, or fax. The department is available from 8:30am to 5:00pm, Central Time, Monday through Friday. Closed holidays. Address: Suburban Surgical Co., Inc. 275 Twelfth Street Wheeling, Illinois Telephone: Illinois - (847) , ext Toll Free - (800) Fax: (847) Web: 6 SSCI - Suburban Surgical Company, Inc.

13 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Ultima Dental Systems Address: 809 NW 57th Street Ft. Lauderdale, FL Telephone: (Technical Assistance) Fax: Warranty Suburban Surgical Company, Inc. warrants the original purchaser that our products are of the highest standards in material and workmanship. Our stainless steel components are guaranteed to last a lifetime assuming they are used as intended, properly maintained and cared for. Mechanical, electrical, electronic, hydraulic, and any product s devices carry a one year warranty. Items purchased by Suburban Surgical Company, Inc. from other manufacturers and incorporated into our equipment are covered by the respective manufacturer s warranties. Warranties will not apply if it is determined by Suburban Surgical Company, Inc. that the equipment became defective due to an accident, misuse, abuse, improper maintenance or alteration. Warranty freight charges are covered for the first year only. Form No April,

14 Chapter 1 - General Information Comments: 8 SSCI - Suburban Surgical Company, Inc.

15 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 2 - Installation & Setup General This chapter guides you in installing and setting up the Regal 6 Dental Procedure Table and Ultima 250 Dental Unit. If you have problems or require additional assistance, please feel free to call SSCI Customer Service at (800) Unpacking & Inspection CAUTION: Unpacking the table and dental unit is not difficult. The items are heavy, however, and we recommend that unpacking be done by at least two people. If the shipping container appears damaged in any way, contact the shipping company immediately. Save all damaged packing materials to assist in proving liability for damage. Carefully inspect the table and dental unit as you unpack them. If any damage is noted, or if parts appear to be missing, call SSCI Customer Service at (800) Lifting the Dental Table CAUTION: Lifting the dental unit by the section over the knee space can damage the table frame. The dental table is very heavy and should be only lifted by two to four persons at the points shown in Figure 1. NEVER try to lift the table by the knee space end as this can damage to the center of the table frame. Lift Here o Lift Here o KNEE SPACE END DO NOT LIFT IN THIS AREA Figure 1. Correct Lifting Points on the Dental Table Form No April,

16 Chapter 2 - Installation & Setup Installation - Regal 6 Dental Procedure Table Preparation Installation Procedure The Regal Dental Procedure Table comes fully assembled. The only work required is the installation of the faucets and connection to electricity, water supply and drain. SSCI recommends a thorough cleaning before placing the table in service. Please read this Owner s Manual before using the table, and then safely file the manual where it can be quickly accessed for future reference. Overview The following instructions give you a general plan for installing the dental procedure table. Since every installation will be unique, it is obviously impractical to specify exact instructions for every case. The photos show knee-space right tables, however, knee-space left tables are exact mirror-images. Tools & Supplies Required! Plumbing tools and supplies as needed! Electric drill and hole cutters of required sizes Installation Sequence 1. Determine the dental table location. 2. Open the side or rear wall (if necessary to pipe in the faucet and drain - this step may not be required on newconstruction). 3. Install the piping for the faucet and drain and electrical wiring 4. Open holes in the table walls for piping & wiring. 5. Finish the wall. 6. Place the table in position. 7. Connect the drain. 8. Install the faucets & sprayer. 9. Mount the dental unit to the swing arm. 10. Finish the job. Determine the Table Location Determine exactly where you want the dental procedure table to be installed. Among other requirements, the location should provide efficient, convenient and cost-effective routing for the faucet and drain plumbing. Open the Wall If this is not new construction, open the wall as necessary to install piping for the dental procedure table faucets and drain. 10 SSCI - Suburban Surgical Company, Inc.

17 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Install the Piping for the Faucet & Drain & Electrical Wiring Install the piping as necessary for the table faucets and drain. Use only deck-mounted faucets - the dental procedure table is not designed for use with wall-mounted faucets. Install the electrical wiring to serve the dental table including a new outlet if necessary. Open Holes in the Table Wall(s) for Piping & Wiring Electricity and plumbing can be brought into the table from the rear wall or side wall depending on the location of the table and the layout of the room (Figure 2):! On knee-space right tables, use rear wall or left wall.! On knee-space left tables, use rear wall or right wall. Locate and open holes as necessary in the rear wall or side wall of the dental procedure table as necessary to facilitate entrance of electricity and drain and water piping. Door Left Side Wall Rear Wall Compressor not shown for clarity Figure 2. Interior View of Typical Dental Procedure Table (knee-space right table shown) Note: The compressor can be pulled out of the cabinet to make working inside easier (refer to Accessing the Compressor on Page 29). While installing wiring and plumbing be sure to allow adequate space for the compressor when it is returned to its in-cabinet position. Form No April,

18 Chapter 2 - Installation & Setup Faucet Holes Sprayer Hole Finish the Wall After plumbing is complete, the wall can be finished. Place the Table in Position Put the table into its intended position. Connect the Drain Connect the drain piping to the tub drain (Figure 3). Drain Hole Install the Faucets & Sprayer 1. Install and connect the faucets and sprayer according to the instructions enclosed with the units (Figure 3). 2. Run water into the dental procedure sink and make sure the plumbing is correct and free of leaks. Figure 3. Faucet, Sprayer, & Drain Locations Mount the Dental Unit to the Swing Arm 1. Remove the dental unit from its container. 2. Pull the swing arm out as far forward as possible. 3. Place the mounting post on the dental unit into the sockete at the end of the swing arm (Figure 4) and push down as far as it will go. Dental Unit Mounting Post Dental Unit Swing Arm Socket Figure 4. Mounting the Dental Unit to the Swing Arm 12 SSCI - Suburban Surgical Company, Inc.

19 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit 4. Place the foot controller in a convenient location near the dentist s chair. 5. Plug the black plug from the dental table into the terminal on the black box under the dental unit (Figure 5). 6. Remove the dental unit cover (refer to Accessing the Dental Unit Interior on Page 30). 7. Locate the thin, white double-wire coming from the dental table. 8. Insert this wire up through the hole in the bottom of the dental unit. 9. Strip back the two wires, if necessary, and connect the wires to the two vacant terminals on the blue connector (Figure 6). 10. Replace the dental unit cover. Black Plug from Table Dental Unit Swing Arm Black Box Under Dental Unit. Figure 5. Plugging in the Black Plug Form No April,

20 Chapter 2 - Installation & Setup White Double- wire Blue Connector Figure 6. Connecting the White Double-Wire Finish the Job 1. Place the basket strainer into the drain hole. 2. Place a dental rack on the table, if desired. 3. On the compressor(s), unscrew the red shipping cap(s) (Figure 7) and install the air filter. 4. Plug the compressor power cord into one of the outlets inside the cabinet. 5. Plug the unit power cord into any standard 115VAC, 60 Hz outlet. Air Filter (installed) Red Shipping Cap (filter removed) Handpiece Air Pressure Screws Filtered Air In Pressurized Water Out Figure 7. Shipping Plug & Air Filter Figure 8. Rear of Dental Unit 14 SSCI - Suburban Surgical Company, Inc.

21 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Testing the Installation 1. Remove any shipping stops or bindings. 2. Make sure that the air tubing between the supplied male quick-disconnect and the female quick-disconnect on the side of the unit labeled FILTERED AIR IN is 1/4-inch diameter (Figure 8). If not, replace it with tubing of the correct size. 3. Connect the incoming air line to a filtered and regulated source (compressor, nitrogen, etc.). CAUTION: Never exceed 80 psi air pressure going into the dental unit. 4. Set the incoming air regulator to 70 psi. Water Bottle Connectors 5. Fill both bottles with distilled water Refer to Refilling the Water Bottles on Page 26. Screw both bottles into their connectors under the dental unit (Figure 9). 6. Set the water on/off switch to ON (Figure 25). 7. Place a handpiece onto each handpiece hose. Water Bottles 8. In turn, pick up each handpiece from its Figure 9. Water Bottles & Connectors handpiece holder and press the foot controller. Make sure the handpiece runs correctly. 9. If necessary, reset the water pressure with the water volume control knob (Refer to Water Controls) on Page Set the handpiece air pressures (Refer to Adjusting Handpiece Air Pressures on Page 25). 11. Test the water, air and mist functions on the syringe by pressing the buttons as follows:! Water Only - Press Left Button! Air Only - Press Right Button! Mist (Air & Water) - Press both buttons at the same time. Form No April,

22 Chapter 2 - Installation & Setup Left Gauge Right Gauge 12. Run the compressor and make sure that it is operating correctly. The compressor gauges (Figure 610 should read as follows:! Left Gauge psi! Right Gauge - Compressor should turn on at 80 psi. and turn off at 120 psi The compressor should hold pressure for at least 5 minutes. Figure 10. Compressor Gauges 16 SSCI - Suburban Surgical Company, Inc.

23 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 3 - Use & Care of the Regal 6 Table Using Your Regal 6 Table Using the Drawers Full-width Drawer Pull Opening & Closing the Drawers The following instructions apply to both three and four drawer tables. The drawers on the Regal 6 Table are designed to work smoothly even with heavy loads. To open a drawer, turn your palm upward and, with your fingertips, grasp the full-width pull (Figure 11), then gently pull the drawer open. To close the drawer, gently push the drawer in. Avoid overfilling the drawers so that the contents obstruct the movement of the drawers. Removing & Replacing a Drawer To remove a drawer, hold up the forward ends of the black catches on both sides of the drawer (Figure 12) and pull the drawer out. Figure 11. Full-width Drawer Pull Black Catch To replace the drawer: 1. Pull both telescoping slides out (Figure 13). 2. Put the drawer tracks on the slides so that the lower tabs on the catches enter the slots on the slides. Telescoping Slide Track rw Hold UP to Release 3. Push the drawer in. Slots for lower tabs on catches Figure 12. Removing & Replacing a Drawer Telescoping Slides Figure 13. Drawer Telescoping Slides Form No April,

24 Chapter 3 - Use & Care of the Regal 6 Table Using the Cabinet Doors Full-width Door Pull Figure 14. Full-width Door Pull Release Catch Squeeze here to release o r Hinge Opening & Closing the Cabinet Door The cabinet door on the Regal 6 Table open approx. 110 for full and easy access to the interior. To open the door, turn your palm upward and, with your fingertips grasp the full-width pull (Figure 14), and gently pull the door open. The door will hold itself open. To close the door, gently push the door closed and the door will stay closed. The doors feature positive-action invisible hinges, and 3D micro-adjustment ensures correct door alignment. Hinges - Overview The hinges used on the cabinet doors are sturdy, high quality devices. The following paragraphs will be helpful when removing or installing a door, or when adjusting the fit of a door in the cabinet. Figures 15 and 16 show close-up images of unmounted hinges to give you detailed views which would be difficult to obtain with the hinges mounted in place. Removing a Cabinet Door The design of the hinges makes it easy to remove a cabinet door from the cabinet. To remove a door, squeeze the release catch on the hinge (Figure 15) and the hinge releases from the hinge mounting plate. When both hinges are free, the door can be removed from the cabinet. Hinge Retaining Pin Hinge Mounting Plate Figure 15. Hinge & Hinge Mounting Plate (unmounted) Locking Groove Hinge Mounting Plate Figure 16. Hinge & Hinge Mounting Plate Separated 18 SSCI - Suburban Surgical Company, Inc.

25 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Installing a Cabinet Door Mount two hinges to the door and two hinge mounting plates to the cabinet. Hook the retaining pin on the hinge into the locking groove in the hinge mounting plate (Figure 16). Then, pivot the hinge closed and press the end of the hinge down until it snaps into place. Do the same to both hinges to secure the door to the cabinet. Adjusting the Door Left-to-Right An adjustment on the hinge moves the door left and right within the door frame. By adjusting both hinges, you can center the door to provide equal spacing on the left and right. The door must be mounted on the cabinet to make this adjustment. Tool Required: Phillips screwdriver Procedure: 1. Close the cabinet door. 2. Observe the gaps between the left and right sides of the door and the door frame (Figure 17). 3. Open the door. 4. With a Phillips screwdriver, turn the left-right adjustment screw (Figure 18) clockwise to move the door to the right; counterclockwise to move the door to the left. 5. Close the door and check the gaps. 6. Open the door and repeat the adjustment if necessary. 7. Continue as above until the gaps are equal. 8. Repeat the procedure for the other hinge. qp Left Side Door qp Right Side Left-Right Adjustment Screw Figure 17. Adjusting the Door Left-Right Figure 18. Door Left-Right Adjustment Screw Form No April,

26 Chapter 3 - Use & Care of the Regal 6 Table Adjusting the Door In & Out An adjustment on the hinge moves the door in and out in the door frame. By adjusting both hinges, you can make the hinge side of the door flush with the door frame. The door must be mounted on the cabinet to make this adjustment. Tool Required: Phillips screwdriver Procedure: 1. Close the cabinet door. 2. Observe whether or not the hinge side of the door is flush with the cabinet frame (Figure 19). 3. Open the door. 4. With a Phillips screwdriver, turn the in-out adjustment screw (Figure 20) clockwise to move the door in; counterclockwise to move the door out. 5. Close the door and check to see if the door is flush with the cabinet frame. 6. Open the door and repeat the adjustment if necessary. 7. Continue as above until the door is flush with the frame. 8. Repeat the procedure for the other hinge. qp Door Edge Not Flush With Cabinet Frame In-Out Adjustment Screw Figure 19. Adjusting the Door In-Out Figure 20. Door In-Out Adjustment Screw 20 SSCI - Suburban Surgical Company, Inc.

27 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Using Prep Procedure Racks Overview Several styles of racks are available for use with the table. The racks are all easily removable without tools for cleaning or other activities. The available racks are:! Flat prep procedure rack! V prep procedure rack! Extension rack for faucet area! Solid removable top Removing & Installing a Rack CAUTION: Removing and installing a rack is not difficult. The rack is heavy, however, and handling it can be awkward for one person. We recommend that removal and installation of a rack be done by at least two people. To remove a rack, simply pick it up by hand and lift it off the table Figure 21). To install a rack, merely set it in place on the table. Note: If the rack does not to seem to fit, rotate it 180 and try again. Prep Procedure Rack (Flat Rack shown) Figure 21. Prep Procedure Rack Form No April,

28 Chapter 3 - Use & Care of the Regal 6 Table Keeping Your Regal 6 Table Clean Introduction You will no doubt want to clean your dental procedure table frequently. Maintaining high standards of sanitation will be an important priority for your facility. CAUTION: The warranty for this product is void if the care and cleaning instructions provided here are not followed. Stainless Steel Cleaning Procedures Rinse the stainless steel portions of the dental procedure table with clear water and dry thoroughly with clean, soft cloths. Ordinary deposits of waste and fluids can usually be removed with soap and water. Stubborn deposits may require scrubbing with stainless steel wool, nylon or plastic scrubbers and/or the use of commercial cleaning products. Always scrub in the direction of the grain of the metal. Rinse with clear water and dry thoroughly with clean, soft cloths. Minor scale build-up and some hard water spotting may be removed by washing with vinegar, followed by a neutralizing rinse of clear water and a thorough drying with clean, soft cloths. For heavy deposits of scale, 5% oxalic acid (use warm), 5-15% sulfamic acid, or 5-10% phosphoric acid may be used. As always, rinse with clear water and dry thoroughly with clean soft cloths. Avoid prolonged use of chlorides (such as chlorine bleach), bromides, iodides, and thiocyanates. Never allow salty solutions to dry on the stainless steel. Refer to Care & Cleaning of Stainless Steel on Page 5 for more detailed information. 22 SSCI - Suburban Surgical Company, Inc.

29 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 4 - Use & Care of the Dental Unit Unit Initial Set-up for Your Dental Unit Most of these steps should have been performed during the installation of the dental unit and table. They are important, however, and should be double-checked before operating the system. 1. Make sure that the air tubing between the supplied male quick-disconnect and the female quick-disconnect on the side of the unit labeled FILTERED AIR IN is 1/4-inch diameter (Figure 22). If not, replace it with tubing of the correct size. 2. Connect the incoming air line to a filtered and regulated source (compressor, nitrogen, etc.). Handpiece Air Pressure Screws Filtered Air In Pressurized Water Out Air Filter (installed) Red Shipping Cap (filter not installed) Figure 22. Rear of Dental Unit Figure 23. Shipping Plug & Air Filter 3. On each compressor, unscrew the red shipping cap (Figure 23) and screw on the air filter. CAUTION: Never exceed 80 psi air pressure going into the dental unit. 4. Set the incoming air regulator to 70 psi. 5. Two one-liter plastic bottles are supplied with the unit. Fill both bottles with distilled water, or if you prefer, fill one bottle with distilled water and the other bottle with a 2% solution of chlorhexadine. Refer to Refilling the Water Bottles on Page 26. Form No April,

30 Chapter 4 - Use & Care of the Dental Unit Water Bottle Connectors CAUTION: When using chlorhexadine, flush the lines with distilled water for 30 seconds to one minute after finishing working. Failure to flush the lines can allow the chlorhexadine to dry and form particles that can clog the water lines and damage or destroy your handpiece. 6. Screw both bottles into their connectors under the dental unit (Figure 24). Water Bottles Figure 24. Water Bottles & Connectors Operating Your Ultima 250 Dental Unit Water Controls General On the right side of the dental unit is the water control panel with two knobs and two switches (Figure 25):! On/Off Switch! Water Volume Control Knob! Bottle Selector Switch Scaler Control Knob Bottle Selector Switch Water Volumn Control Knob Front of Dental Unit On/Off Switch Right Side of Dental Unit Figure 25. Water Control Panel On/Off Switch This two-position switch turns the water on and off to handpiece lines 2 and 3. Just flip the switch to the desired position. 24 SSCI - Suburban Surgical Company, Inc.

31 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Water Volume Control Knob This variable-position knob controls the water volume to handpieces 2 and 3. Turn the knob:! Counterclockwise to increase water volume! Clockwise to decrease. Bottle Selector Switch This two-position switch (Figure 25) allows you to change between Bottle 1 and Bottle 2. Both bottles may contain distilled water or, if you prefer, one may contain distilled water and the other chlorhexadine. Handpiece Holders On the dental unit, the three handpiece holders are color-coded with colored bands on the end of the handpiece hose, and matching color disks next to each handpiece position Figure 26). The handpieces are color-coded as follows:! 1 - Red! 2 - White! 3 - Blue 1 - Red 2 - White 3 - Blue Scaler & Handpieces Not Shown Figure 26. Color-Coded Handpiece Holders Red Air Line The red air line is set at psi for your lowspeed polisher. This line is dry. White Air Line The white air line is your accessories line and has not been set to any particular air pressure. It is a very good position for your sonic scaler. If a scaler is used, pressure should be about 42 psi. Blue Air Line The blue air line is set at psi for your high-speed handpiece. Adjusting Handpiece Air Pressures Recommended Handpiece Air Pressures The recommended air pressures for the three handpiece air lines are:! Polisher, HP1 (red line) psi! Sonic Scaler, HP2 (white line) - 42 psi! High-speed Drill HP3 (blue line) - 32 psi Form No April,

32 Chapter 4 - Use & Care of the Dental Unit Adjusting Handpiece Air Pressures On the upper back of the dental unit are three small holes (Figure 27). Inside these holes are small, silver screws that control air pressure to the individual handpieces. To adjust air pressure turn the screws:! Clockwise to lower air pressure.! Counterclockwise to increase air pressure To adjust handpiece air pressures: 1. Connect the handpiece to the appropriate handpiece hose. 2. Step on the foot controller. 3. While observing the air pressure gauge (Figure 28) on the front panel, turn the appropriate silver screw in holes HP1, HP2 or HP3 as described in the paragraph above. Note: It may take two or three turns before any change occurs. Air Pressure Screws (3) Filtered Air In Pressurized Water Out Air Pressue Gauge Figure 27. Air Pressure Adjustment Screws Figure 28. Air Pressure Gauge Refilling the Water Botttles It is not necessary to disconnect the unit from the air source to refill the water bottles. To refill a water bottle: 1. Slowly unscrew the bottle from its connector under the dental unit (Figure 16) until you hear air escaping. 2. Wait 2 seconds. 3. Unscrew the bottle completely and remove it from the unit. 26 SSCI - Suburban Surgical Company, Inc.

33 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit CAUTION: Always use distilled water in the dental unit. NEVER use tap water. 4. Refill the bottle with distilled water (or 2% solution of chlorhexadine, if preferred). 5. Hold the bottle under the correct connection under the unit and place the transfer tube into the bottle. 6. Screw the bottle firmly in. Using the Three-Way Syringe The three-way syringe can give you a solid stream of water, a blast of air, or a mist. To select one option, press the syringe buttons (Figure 29) as follows:! Water Only - Press Left Button! Air Only - Press Right Button! Mist (Air & Water) - Press both buttons at the same time. Left Button Right Button Syringe Figure 29. Selecting Water, Air & Mist on the Syringe Form No April,

34 Chapter 4 - Use & Care of the Dental Unit Checking Compressor Gauges Correct Settings When operating normally, the compressor gauges (Figure 30) should read as follows:! Left Gauge psi! Right Gauge - Compressor should turn on at 80 psi. and turn off at 120 psi If a compressor is operating at pressures substantially different than those listed above, there may be a problem with your air system. Left Gauge Right Gauge Air Regulator Figure 30. Compressor Gauges Figure 31. Air Regulator Adjusting Air Pressure If the left gauge does not read psi, push down on the air regulator knob (Figure 31) and turn it until the gauge reads correctly. If the right gauge reads incorrectly or if the compressor does not turn on and off at the specified pressures, call Ultima Dental Technical Assistance at Accessing the Compressor To make servicing the compressor easier, it can pulled out of the cabinet like a drawer. To access the compressor: 1. Open the compressor cabinet door. 2. Rotate the lock (Fig. 32) upward so it clears the compressor unit. 3. Grasp the compressor assembly and pull it forward and out of the cabinet (Fig. 33). 28 SSCI - Suburban Surgical Company, Inc.

35 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit To close the compressor drawer: 1. Push the compressor assembly all the way into the cabinet. 2. Rotate the lock downward to secure the compressor assembly. 3. Close the compressor cabinet door. Lock to unlock D Compressor Assembly Compressor Cabinet Doot Pull Out p Figure 32. Compressor Lock Using the Foot Controller Figure 33. Opening Compressor The Ultima 250 Dental Unit uses a disk-shaped foot controller (Figure 34). To control handpiece speed, press down with your foot anywhere on the controller rim. Varying the speed of the handpiece is done by increasing or decreasing your foot pressure just like the accelerator on your automobile. Foot Controller Cord p p p p p Press Anywhere on Controller Rim to Operate Handpiece Figure 34. Foot Controller Form No April,

36 Chapter 4 - Use & Care of the Dental Unit Accessing the Dental Unit Interior You may gain easy access to the interior of the dental unit to perform inspections or repairs. To access the interior of the dental unit: 1. Turn the silver, knurled screw on the top rear of the unit (Figure 35) counterclockwise to unscrew. When the screw pops up slightly, the screw is free of the dental unit. Do not try to remove the screw from the cover. 2. Slide the dental unit cover to the rear and remove it from the unit. To close the dental unit cover: 1. Slide the unit cover forward so that the lip under the front of the cover slides under the front panel. 2. Press the silver screw down until the threads engage, then turn it clockwise to secure. Cover shown partially open r Lip o Dental Unit Cover Silver Knurled Screw Filtered Air In Pressurized Water Out Figure 35. Removing the Dental Unit Cover Figure 36. Air Pressure Adjustment Screws Connecting an Ultrasonic Scaler If you wish to connect a separate tabletop ultrasonic scaler to the dental unit, plug the scaler s water line into the connector on the back of the dental unit labeled Pressurized Water Out (Figure 36). Place the scaler handpiece in the center handpiece holder (white). 30 SSCI - Suburban Surgical Company, Inc.

37 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Maintaining Your Dental 250 Dental Unit Cleaning Procedure Routine Maintenance Cleaning procedures for the Ultima 250 Dental Unit are very simple and basic. Simply wipe the unit down daily with any common disinfectant. Perform the maintenance steps listed below at the specified time intervals. CAUTION: The warranty for this product is void if the care and cleaning instructions provided in this manual are not followed. CAUTION: Always use distilled water in the dental unit. NEVER use tap water. Maintenance Schedule Table 2 lists the recommended maintenance procedures and the intervals at which they should be carried out. Where appropriate, the table shows where the details of each procedure are given in this manual. Interval Daily Procedure Unplug unit at end of every working day. Disconnect air line from unit each night and allow unit to vent. Wipe dental unit down with disinfectant. Reference None Flush water lines after using chlorhexadine. Page 32 Weekly Oil Handpieces. Page 32 Check oil level in compressor and top up if necessary. Page 32 M onthly Drain compressor holding tank. Page 33 Annually Drain oil from compressor and replace with new oil. Page 34 Table 2. Routine Maintenance Schedule for the Ultima 250 Dental Unit Form No April,

38 Chapter 4 - Use & Care of the Dental Unit Routine Maintenance Procedures Flush Water Lines After Using Chlorhexadine After using chlorhexadine, use the bottle selector switch (refer to Figure 25) to change to the bottle containing distilled water. Flush the handpiece with distilled water for 30 seconds to one minute. Remember, chlorhexadine contains particles which, if allowed to dry inside the handpiece, can form clots that can damage or destroy the handpiece. Oil Handpieces Note: Operating procedures may vary for each handpiece model. Please refer to the operator s manual supplied with each handpiece and follow the manufacturer s specific instructions. A rule-of-thumb for oiling handpieces is as follows:! Less than one use per day - oil once a week! From 1 to 10 uses per day - oil twice a week. Note: Use only liquid handpiece oil. CAUTION: Any attempt to service your compressor by removing the compressor shell or terminal box cover, tampering with the pressure switch setting and/or grounding plug will VOID your warranty and may make the compressor unsafe to use. Electric Power Plug (in outlet) Figure 37. Electric Power Plug Check Oil Level in Compressor To check the oil level in the compressor, unplug the compressor (Figure 37), then view the oil level in the sight glass (Figure 38). The oil level should indicate 1/2 to 2/3 full. If the oil level is below these specification, top up the compressor with oil. Note: If you have a two-head compressor, check the oil in both compressor heads. Top Up Oil Level in Compressor Note: Use only Silent-Surge compressor oil. 1. Unscrew and remove the air filter (Figure 38). 2. Pour oil into hole while watching the sight glass. Top up oil to 1/2 to 2/3 level in sight glass. Note: Adding compressor oil is easier using the filter hole than the oil hole on top. 3. Replace the air filter. 4 If the compressor is two-head, repeat Steps 1 through 3 for the second head. 5. Plug in the compressor power cord. 32 SSCI - Suburban Surgical Company, Inc.

39 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Air Filter Sight Glass (one on each compressor head) Figure 38. Checking & Topping-up Compressor Oil Level Drain Compressor Holding Tank Monthly, drain the compressor holding tank following the instructions below: 1. Allow the dental unit to run without activating any air-powered instrument. Build up full air pressure in the dental unit. 2. Unplug the electrical power cord. 3. Turn the holding tank vent valve counterclockwise to open (Figure 39) until you hear air escaping, then turn the vent 1/2 turn more. 4. Watch the pickup bottle and do not allow it to fill more than 3/4 full. 5. Important: When all air has escaped, close vent valve tightly. 6. Remove, clean and replace the pickup bottle (refer to procedures for removing, cleaning and replacing the pickup bottle below). 7. Plug in the electrical power cord. Vent Valve Pickup Bottle Figure 39. Draining the Compressor Holding Tank Removing, Cleaning & Replacing the Pickup Bottle To remove the pickup bottle from the bottle neck (Figure 40). 1. Remove the metal clip on the bottle neck. 2. Turn the scalloped disk counterclockwise and unscrew it from the bottle. 3. Lift the disk and attached bottle top from the bottle. 4. Lift the pickup bottle out of the holder. Form No April,

40 Chapter 4 - Use & Care of the Dental Unit Scalloped Disk Metal Clip Pickup Bottle Holder Figure 40. Working With the Pickup Bottle Cleaning the Pickup Bottle To clean the pickup bottle: 1. Empty all contents from the bottle and dispose of them in accordance with all local, state and Federal regulations. 2. Wash the bottle thoroughly with hot water and any good detergent. 3. Rinse thoroughly with clear water. Replacing the Pickup Bottle To replace the bottle into the compressor assembly: 1. Place the pickup bottle into the holder (Figure 40). 2. Place the scalloped disk on the bottle top onto the top of the bottle. 3. Turn the disk clockwise to screw it onto the bottle. 4. Snap the metal clip back into place on the bottle neck. Drain Oil From Compressor and Replace With New Oil General Annually, drain all oil from the compressor, fill the compressor with new oil and install new air filters following the instructions below. CAUTION: Use ONLY Silent-Surge Compressor Oil. 34 SSCI - Suburban Surgical Company, Inc.

41 Air Filters Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Sight Glass (one on each compressor head) Figure 41. Draining & Replacing Compressor Needed Parts Order one Ultima Oil Recharge Kit, P/N from Suburban Surgical Company, Inc. (Refer to Page 6 for contact information). This kit includes the special tools and replacement parts you will need for your annual compressor oil change and is used for both single-head and double-head compressors. The kit contains:! One small pump to remove the old oil! Two containers of Silent-Surge Oil! Two air filter elements Procedure 1. Disconnect electrical power from the table. 2. On the compressor head (Figure 41), unscrew and remove the air filter. 3. Unscrew the old filter element from the air filter body. 4. Connect the small tube (supplied) to the bottom fitting of the pump. 5. Connect the large tube (supplied) to the top fitting of the pump. 6. Snake the small tube as far down the air filter hole as you can. 7. Place the large tube into a suitable container for disposal of waste oil. 8. Pump as much oil from the compressor as possible. 9. Dispose of the old oil in accordance with all local, state and Federal regulations. 10. Note: Use only Silent Surge compressor oil. Pour fresh oil (supplied in the kit) into the hole while watching the sight glass. Top up oil to 1/2 to 2/3 level in sight glass. 11. Install a new air filter element (supplied) into the air filter. 12. Screw the air filter onto its fitting. 13. If the compressor is two-head, repeat Steps 2 through 12 for the second head. 14. Reconnect electrical power to the table. 15. Thoroughly clean the pump and save for later use. Form No April,

42 Chapter 4 - Use & Care of the Dental Unit Compressor Safety Tips CAUTION: Any attempt to service your compressor by removing the compressor shell or terminal box cover, tampering with the pressure switch setting, and/or grounding plug will VOID your warranty and may make your compressor unsafe to use.! Carefully inspect the hoses, fittings and overall appearance of the compressor before each use.! Always operate the compressor on a level surface.! Periodically check the oil level at the sight glass.! Use only a properly grounded outlet that will accept 3-pronged plugs. Never operate the compressor with a damaged cord.! Keep the compressor free of dust, dirt and paint. This will prolong the air filter operation and prevent clogging of the safety release valve.! Do not substitute or mix your compressor oil with other brands or types. Any attempt to use oil different from that specified by the manufacturer will result in compressor breakdown and will VOID your warranty.! To reduce the risk of electric shock, do not allow the unit to be exposed to water while in use.! Never attempt to service the compressor while it is plugged into an electrical outlet.! Avoid direct contact with the compressor surface while operating. High temperatures may be present.! Use only factory authorized parts.! When not in use, make sure that the air pressure has been released from the system.! The compressor must be OFF when checking oil level. CAUTION: Any attempt to service your compressor by removing the compressor shell or terminal box cover, tampering with the pressure switch setting, and/or grounding plug will VOID your warranty and may make your compressor unsafe to use. 36 SSCI - Suburban Surgical Company, Inc.

43 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Cleaning Your Ultima 250 Introduction Cleaning Procedure You will no doubt want to clean your Ultima 250 Dental Unit frequently. Maintaining high standards of sanitation will be an important priority for your facility. Keeping the Ultima 250 clean is simple and easy. Daily, wipe the dental unit down with the disinfectant of your choice. CAUTION: The warranty for this product is void if the care and cleaning instructions provided in this manual are not followed. Form No April,

44 Chapter 4 - Use & Care of the Dental Unit Comments: 38 SSCI - Suburban Surgical Company, Inc.

45 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 5 - Parts Replacement, Regal 6 Replacement Parts Table 3 is a list of replacement parts available for the Regal 6 Dental Procedure Table. For these replacement parts, contact Suburban Surgical Company, Inc. Refer to Page 6 for contact information. For replacement parts for the Ultima 250 Dental Unit, refer to Chapter 6 on Page 49. Description SSCI Part Number Quantity Replacement Instructions Cabinet Door Hinged Left DBDXAC Hinged Right DBDXAC 1 Page 41 Door Hinge per Door Page 42 Door Plate Hinge Mounting per Hing e Page 43 Drawer 3-Drawer Tables DBBHDJ 4-Drawer Tables DBAYDJ 3 or 4 Page 44 Drop-in Tub Flat Dental Procedure Rack "V" Dental Rack Procedure JFAUD R 1 Page JFAADR 1 Page JFAADR 1 Page 46 Extension Rack Faucet Area for Flat Racks BWAADR "V" Racks BWAADR 1 None Solid Removable Top JFAAD R 1 Page 46 Removable (Optional) Bathing Rack Stainless Steel IDAFDG Plastisol Coated IDAFDG 1 Page 46 Table 3. Replacement Parts for the Regal 6 Dental Procedure Table General Information! During disassembly, retain all hardware items such as screws, nuts, lockwashers, etc. for reassembly.! If you have problems with any procedure, please feel to call SSCI Customer Service at (800) Form No April,

46 Chapter 5 - Parts Replacement - Regal 6 Parts Ordering Procedure Returning the Dental Procedure Table for Repairs RMA Numbers Packing & Shipment Order new equipment, accessories, and/or replacement parts for your Regal 6 Dental Procedure Table directly through SSCI Customer Service. You can order by mail, telephone, or fax. Refer to SSCI Contact Information on Page 6 for address, telephone, and fax numbers. When ordering, please provide the following information:! Your name! Company name! Company account number! Telephone number! Fax number! address! Shipping address! Billing address (if different from shipping address)! Names, part numbers, and quantities of items being ordered! Credit card number and expiration date, or other payment information! Preferred method of shipment! Information on whether the items are required on a normal or urgent basis If your dental procedure table should require return to SSCI for repairs, discuss the problem with one of our Customer Service Representatives. Obtain an RMA number (Return Merchandise Authorization) from them before shipping the unit back. Note: SSCI will not accept merchandise returned without an RMA number. Package the table securely in a suitable container. Ship documentation with the table including:! Destination! RMA Number! Your name, company, and address! Your telephone number! A description of the reason for returning the table 40 SSCI - Suburban Surgical Company, Inc.

47 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Parts Replacement Procedures Cabinet Door Refer to Table on Page 39 for Part Numbers The following sections guide you in replacing worn, damaged, or missing parts on an SSCI Regal 6 Dental Procedure Table. Overview The following instructions guide you in replacing a cabinet door hinged either left or right. For detailed information on the operation of the hinges, refer to Page 18. Tool Required! Phillips screwdriver Procedure 1. Squeeze on the release catches of both hinges (Figure 34), and remove the door. Refer to Removing a Cabinet Door on Page With a Phillips screwdriver, remove the two screws on each hinge and remove both hinges from the old door (Figure 43). 3. With the screws removed above, mount the hinges on the new door. 4. Mount the door in the cabinet - engage the hinges into the hinge mounting plates, and snap the hinges into place. Refer to Installing a Cabinet Door on Page Observe how the door fits in the cabinet. If necessary, adjust the door; refer to Adjusting the Door Left-to- Right on Page 19 and Adjusting the Door In & Out on Page 20. Door Mounting Screws Release Catch Figure 42. Door Hinge Release Catch Figure 43. Hinge Mounted on Door Form No April,

48 Chapter 5 - Parts Replacement - Regal 6 Door Hinge P/N Overview The following instructions guide you in replacing a door hinge. All door hinges are identical whether the door is hinged-left or hinged-right. For detailed information on the operation of the hinges, refer to Page 18. Tool Required! Phillips screwdriver Procedure 1. Open the cabinet door. 2. Squeeze on the release catches of both hinges (Figure 42), and remove the door from the cabinet. Refer to Removing a Cabinet Door on Page 18. Door Mounting Screws 3. With a Phillips screwdriver, remove the two mounting screws on the hinge and remove the hinge from the door (Figure 44). 4. Using the two screws removed above, mount the new hinge to the door. Figure 44. Hinge Mounted on Door 5. Mount the door in the cabinet - engage the hinges into the hinge mounting plates, and snap the hinges into place. Refer to Installing a Cabinet Door on Page Observe how the door fits in the cabinet. If necessary, adjust the door. Refer to Adjusting the Door Left-to-Right on Page 19 and Adjusting the Door In-&- Out on Page SSCI - Suburban Surgical Company, Inc.

49 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Door Hinge Mounting Plate P/N Overview The following instructions guide you in replacing a door hinge mounting plate. There is one mounting plate behind each door hinge. All door hinge mounting plates are identical. For detailed information on the operation of the hinges, refer to Page 18. Tool Required! Phillips screwdriver! Pliers Procedure 1. Open the cabinet door. 2. Squeeze on the release catches of both hinges Figure 34), and remove the door from the cabinet. Refer to Removing a Cabinet Door on Page 42. Mounting Screws 3. With a Phillips screwdriver, remove the two screws on the hinge mounting plate and remove the plate from the cabinet wall (Figure 45). 4. On the new mounting plate, two dark gray plastic thread guards protect the plate mounting screws. Hold each guard with a pliers and, with a Phillips screwdriver, undo the screws. Discard the guards. Figure 45. Door Hinge Mounting Plate 5. Mount the new mounting plate to the cabinet wall using the new screws supplied with the plate. 6. Mount the door in the cabinet - engage the hinges into the hinge mounting plates, and snap the hinges into place. Refer to Installing a Cabinet Door on Page Observe how the door fits in the cabinet. If necessary, adjust the door. Refer to Adjusting the Door Left-to- Right on Page 19and Adjusting the Door In & Out on Page 20. Form No April,

50 Chapter 5 - Parts Replacement - Regal 6 Drawer Refer to Table on Page 39 for Part Numbers Overview The following instructions guide you in replacing a drawer. They are appropriate for both three and four drawer tables. Procedure 1. Remove all items from the drawer. 2. Hold up the black catches on both sides of the drawer (Figure 46) and pull the drawer out. 3. To replace the drawer, pull both telescoping slides out. 4. Put the drawer tracks on the slides so that the tabs on the catches enter the slots on the slides (Figure 47). 5. Push the drawer in. Catch Slots for lower tabs on catches Telescoping Slide Track rw Hold UP to Release Telescoping Slides Figure 46. Removing & Replacing a Drawer Figure 47. Drawer Telescoping Slides 44 SSCI - Suburban Surgical Company, Inc.

51 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Drop-in Tub Refer to Table on Page 39 for Part Numbers Overview The following instructions guide you in replacing a drop-in tub. Tools Required! Plumbing tools as necessary Procedure CAUTION: Removing and installing a drop-in tub is not difficult. The tub is heavy, however, and handling it can be awkward for one person. We recommend that removal and installation of a drop-in tub be done by at least two people. 1. Remove any dental procedure rack that may be on the table. 2. Remove the basket strainer from the drain opening. 3. Disconnect and remove the faucets, sprayer, and drain from the drop-in tub. 4. Lift the drop-in tub off (Figure 48). Be careful, it s a tight fit! 5. Place the new drop-in tub onto the table. 6. Reconnect the drain, faucets, and sprayer. 7. Replace the basket strainer and dental procedure rack. Drop-in Tub Figure 48. Drop-in Tub in Dental Procedure Table Figure 49. Drop-in Tub Form No April,

52 Chapter 5 - Parts Replacement - Regal 6 Dental Procedure Rack (Flat Rack Standard, Other Racks Optional) Refer to Table on Page 39 for Part Numbers Overview The following instructions apply to all types of dental procedure racks for the Regal 6 Dental Procedure table. Procedure CAUTION: Removing and installing a rack is not difficult. The rack is heavy, however, and handling it can be awkward for one person. We recommend that removal and installation of a rack be done by at least two people. To remove a rack, simply pick it up by hand and lift it off the table (Figure 50). To install a rack, merely set it in place on the table. Note: If the rack does not to seem to fit, rotate it 180 and try again. Dental Procedure Rack (Flat Rack shown) Figure 50. Dental Procedure Rack 46 SSCI - Suburban Surgical Company, Inc.

53 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Removable Bathing Rack (Optional) Refer to Table on Page 39 for Part Numbers Overview The following instructions apply to both stainless steel and plastisol coated removable bathing racks for the Regal Dental Procedure table. Procedure CAUTION: Removing and installing a rack is not difficult. The rack is heavy, however, and handling it can be awkward for one person. We recommend that removal and installation of a rack be done by at least two people. To remove a rack, simply pick it up by hand and lift it out of the tub (Figure 50). To install a rack, merely set it in place in the tub. Removable Bathing Rack Sink shown removed from table Figure 51. Removable Bathing Rack in Drop-in Tub Form No April,

54 Chapter 5 - Parts Replacement - Regal 6 Comments: 48 SSCI - Suburban Surgical Company, Inc.

55 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 6 - Parts Replacement, Ultima 250 Replacement Parts If you require replacement parts for the Ultima 250 Dental Unit.:! For those parts listed in Table 3, Page 39, contact Suburban Surgical Company, Inc.! For replacement parts for the dental unit, contact Ultima Dental Systems Technical Assistance. For phone numbers, fax numbers, etc, refer to Contact Information on Page 6. For replacement parts for the Regal 6 Dental Procedure Table, refer to Chapter 5 on Page 39. Parts Ordering Procedure Order new equipment, accessories, and/or replacement parts directly from the manufacturer as listed below:! For those parts listed in Table 3, Page 39, contact Suburban Surgical Company, Inc.! For replacement parts for the dental unit, contact Ultima Dental Systems Technical Assistance. You can order by mail, telephone, or fax. Refer to Contact Information on Page 6 for address, telephone, and fax numbers. Form No April,

56 Chapter 6 - Parts Replacement - Ultima 250 When ordering, you will probably be asked to provide the following information:! Your name! Company name! Company account number! Telephone number! Fax number! address! Shipping address! Billing address (if different from shipping address)! Names, part numbers, and quantities of items being ordered! Credit card number and expiration date, or other payment information! Preferred method of shipment! Information on whether the items are required on a normal or urgent basis Returning the Dental Unit or Compressor for Repairs If your dental unit or compressor should require return to the manufacturer for repairs, discuss the problem with the appropriate company s Technical Support department and follow their instructions.! Regal 6 Dental Table - Suburban Surgical Company! Ultima 250 Dental Unit - Ultima Dental Systems For phone numbers, fax numbers, etc, refer to Contact Information on Page SSCI - Suburban Surgical Company, Inc.

57 Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Chapter 7 - Troubleshooting General The following procedures will help you fix most of the problems that you might encounter with your Regal 6 Dental Procedure Table with the Ultima 250 Dental Unit.! For problems with the Regal 6 Table, call SSCI Technical Service at (800) ! If technical assistance is required for the Ultima 250, call Ultima Dental Systems Technical Assistance at (954) Problems Possible problems are listed below along with their page references in this chapter:! No water Page 52! Polisher Problems Page 53! Insufficient Air Pressure to Handpieces Page 54! Compressor Will Not Run Page 55! Compressor Does Not Turn Off Page 56! Compressor Runs But Does Not Supply Air Page 57! Air Leak Page 58! Compressor Makes a Rattling Noise During Operation Page 59! Compressor Oil Appears Milky Page 60! Air Tank Does Not Hold Pressure When Compressor Is Not Running. ---Page 61! No Air Pressure Shown on Regulator Gauge Page 62 Form No April,

58 Chapter 7 - Troubleshooting No Water. Remedial Action First: Make sure that the Water On/Off switch is ON (refer to Page 22) Second: Make sure that the Water Volume Control Knob is open (refer to Page 24). Third: Feel the water bottles. They should be very hard. If not, make sure they are screwed in tightly and properly filled with water. Fourth: Check the prophy angle. Make sure it is correctly connected to the handpiece hose. Check the manufacturer s instructions to make sure the angle is operating properly. Fifth: Try operating the 3-way Syringe. If it operates OK, the problem is probably not with the water supply. If it does not operate, there is a problem with your water supply. Check incoming water lines and connections to make sure there are no leaks or constrictions. Sixth: If none of these actions cure the problem, call Ultima Dental Technical Assistance at SSCI - Suburban Surgical Company, Inc.

59 Polisher Problems. Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Remedial Action First: Check air pressure to the angle. It should be psi. Second: Make sure that the chuck is in the closed position. Third: Turn the collar with the two small screws counterclockwise to unlock. Remove the prophy angle and try to turn the axle. If you cannot turn the axle, you will have to order a new prophy angle. Fourth: If none of these actions cure the problem, call Ultima Dental Technical Assistance at Form No April,

60 Chapter 7 - Troubleshooting Insufficient Air Pressure to Handpieces. Remedial Action First: Make sure that the handpiece is securely connected to the handpiece hose. Second: Check to make sure the handpiece air pressure is correct. The recommended air pressures for the three handpiece air lines are:! Polisher, HP1 (red line) psi! Sonic Scaler, HP2 (white line) - 42 psi! High-speed Drill HP3 (blue line) - 32 psi Third: Check all air lines for leaks, loose connections, kinks, or hose damage. Fourth: Make sure that the compressor is operating correctly and that the compressor gauges read correctly. When operating normally, the compressor gauges (Figure 30) should read as follows:! Left Compressor psi! Right Compressor - Should turn on at 80 psi. Should turn off at 120 psi If a compressor is operating at pressures substantially different than those listed call your local compressor service. Fifth: If none of these actions cure the problem, call Ultima Dental Technical Assistance at SSCI - Suburban Surgical Company, Inc.

61 Compressor Will Not Run. Owner s Manual - Regal 6 Dental Procedure Table with Ultima 250 Dental Unit Remedial Action First: The incoming power cord to the unit may be unplugged or damaged. If the cord is unplugged, plug it back in. If the cord is damaged, replace it with a new cord. Second: There may not be electrical power to the compressor. Check outlet voltage and fuse or circuit breakers. Third: You may be using an incorrect extension cord. If using an extension cord, make sure it is UL-approved, heavy-duty and properly grounded. Fourth: Compressor head pressure may not be relieved enough for the motor to cut in. Manually, relieve air pressure in the air tank by turning the handle on the vent valve counterclockwise (Figure 52). After the air has escaped, firmly tighten the vent valve. Vent Valve Figure 52. Compressor Vent Valve Fifth: The thermal overload protector may have tripped. Do not operate the compressor for 15-minutes, and try starting again. Sixth: If none of these actions cure the problem, call Ultima Dental Technical Assistance at Form No April,

Classic 6 & 18 Prep Procedure Tables Owner s Manual

Classic 6 & 18 Prep Procedure Tables Owner s Manual Classic 6 & 18 Prep Procedure Tables Owner s Manual Durable, heli-arc welded, stainless steel Variety of styles for your convenience 48-in. and 60-in. widths to suit your needs Removable prep rack SSCI

More information

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart OPERATION and MAINTENANCE INSTRUCTION MANUAL ADU-20B CompriCart TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the Unit...................2 -

More information

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink ESS-2000/3000 Series I.I. Rev. 2 (02/03) Code No. 016162 INSTALLATION INSTRUCTIONS SINGLE, DOUBLE AND TRIPLE STATION SENSOR OPERATED SYSTEMS ESS-2000 SERIES ESS-2100 Single Station Scrub Sink with One

More information

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER I N ST R UC 2612 SLICER T I ON S MODEL 2612 & 2712 SLICERS MODELS 2612 ML-104829 2712 ML-104822 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 34141 (12-98) Installation, Operation, and Care of MODEL 2612

More information

MODEL SF-420. Fabric Steamer. by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card.

MODEL SF-420. Fabric Steamer. by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card. MODEL SF-420 Fabric Steamer by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card. LETTER FROM THE CEO Dear Valued Customer, Congratulations on purchasing

More information

Deluxe Vapor Steamer. Operations Manual

Deluxe Vapor Steamer. Operations Manual Deluxe Vapor Steamer Operations Manual www.detailplus.com www.detailplus.com LIMITED WARRANTY Rules to Remember when using the Vapor Steamer Deluxe The company warrants to the original purchaser that this

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic INSTRUCTIONS PERTAINING TO; RISK OF FIRE, ELECTRIC SHOCK OR HARM TO PERSONS IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic precautions should always be followed, including

More information

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS K 2.97 M High Pressure Washer Operator Manual Overview... 2 Important Precautions... 3-4 Assembly Instructions... 4 Operating Instructions... 5 GFCI Instructions... 6 Using the Accessories... 6 Working

More information

Use and Care Guide. Over the Patient Units and Swing Mount Units

Use and Care Guide. Over the Patient Units and Swing Mount Units Over the Patient Units and Swing Mount Units Table of Contents Page General Information 2 Operation 3-5 Dental Unit Adjustments 6-10 Cleaning, Disinfecting and Sterilization 11-12 Maintenance 13-15 Page

More information

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL Instruction Manual and Warranty Information IM0034A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking

More information

Model K 520 M Part No

Model K 520 M Part No Model K 520 M Part No. 1.069-680.0 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents...

More information

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0036A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...

More information

Hydraulic V-Top & Flat-Top Surgery Tables

Hydraulic V-Top & Flat-Top Surgery Tables Midmark Hydraulic Column Surgery Table Manual Hydraulic V-Top & Flat-Top Surgery Tables Table of Contents Unpacking.... 2 Specifications... 2 Installation... 2 Flat-Top Parts Identification... 3 V-Top

More information

Models: FM FM WARNING

Models: FM FM WARNING Installation Stainless Steel Blowout Urinal Models: 923-8000 923-8001 923-8002FM 923-8003FM Table of Contents Overview...2 Pre-Installation Information...3 Installation Instructions...4-7 Cleaning Instructions...7

More information

Ultrasonic Cool Mist Humidifier

Ultrasonic Cool Mist Humidifier Model No.: LV450CH Ultrasonic Cool Mist Humidifier Questions or or Concerns? Please contact us Monday Mon-Fri 9:00AM-5:00PM - Friday am - PST 5:00 pm PST at support@levoit.com (888) 726-8520 email or at

More information

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER Adorable Humidifiers 1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER FOR THE FOLLOWING MODELS: EE-0865 EE-3186 EE-3189 EE-3190 EE-3191 EE-4139 EE-4140 EE-5058 EE-6369 EE-7270 EE-8189 EE-8190 EE-8243 If you

More information

Water Boilers ME10EN, ME15EN. Table of Contents

Water Boilers ME10EN, ME15EN. Table of Contents Water Boilers ME10EN, ME15EN Operator Manual Model ME15EN Model ME10EN Safety Information...2 Rough-In Drawing...3 Installation...4 Priming...5 Cleaning...5 Table of Contents Adjustments...6 Maintenance...7

More information

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets Installation Operation Maintenance Troubleshooting Version Dec/17 Mobile Cabinets Table of Contents WARRANTY... 3 Important Information... 4 Technical Specifications... 4 Weight & Dimensions... 5 Dimensions...

More information

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care. Droplet Humidifiers FOR THE FOLLOWING MODELS: EE-5302 EE-5302A EE-5302W If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care. Toll Free: 888-599-0992

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Adjustable Push Button and Battery Operated Infrared CWBF-1 Table of Contents Pre-Installation Information...2 Standard Bottle Filler Configurations...3 Physical Dimensions...4

More information

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER Adorable Humidifiers 1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER FOR THE FOLLOWING MODELS: EE-0865 EE-3186 EE-3189 EE-3190 EE-3191 EE-4139 EE-4140 EE-5058 EE-6369 EE-7270 EE-8189 EE-8190 If you have any

More information

V-Top & Flat-Top Surgery Tables. Table of Contents

V-Top & Flat-Top Surgery Tables. Table of Contents Midmark Electric Column Surgery Table Manual V-Top & Flat-Top Surgery Tables Table of Contents Unpacking.... 2 Specifications... 2 Installation... 2 Flat-Top Parts Identification... 3 V-Top Parts Identification..............

More information

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL ADU-10 AseptiMini Pneumatic Portable Dental System TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up

More information

Model Number: HC 1222

Model Number: HC 1222 Owner s Manual Model Number: HC 1222 0 Introduction Thank you and congratulations for choosing the Rainbow Steamer, the Fresher, Cleaner, Healthier steam cleaner. The Rainbow Steamer is an environmentally

More information

MODEL BC14 Bowl Cutter Operations Manual

MODEL BC14 Bowl Cutter Operations Manual MODEL BC14 Bowl Cutter Operations Manual Persons under age 18 are not permitted to operate or have accessibility to operate this equipment per U.S. Dept. of Labor Employment Standards Administration Fact

More information

V. (Versus ) Bare Floor Vacuum

V. (Versus ) Bare Floor Vacuum V. (Versus ) Bare Floor Vacuum USER S GUIDE 76T8 SERIES 3 Safety Instructions 4 Product View 5 Assembly 6 Operation 7-8 Maintenance and Care 9 Troubleshooting 10 Consumer Services 11 Replacement Parts

More information

ELECTRIC STOVE HEATER Models: FS2213B

ELECTRIC STOVE HEATER Models: FS2213B ELECTRIC STOVE HEATER Models: FS2213B OWNER S MANUAL WARNING Read and understand this entire owner s manual, including all safety information, before plugging in or using this product. Failure to do so

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A, PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F, PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF READ AND SAVE THESE INSTRUCTIONS

More information

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL ADU-12 Task Force Pneumatic Portable Dental System TABLE OF CONTENTS: Package Contents....................1 Introduction.........................2 Setting Up

More information

The FAWSsit USER CARE GUIDE

The FAWSsit USER CARE GUIDE The FAWSsit Fold Away Wheelchair Shower US Patent Number 7,231,673 B1 USER CARE GUIDE Recliner R3000 A Note to You Thank you for buying this product. To ensure you enjoy years of trouble-free operation,

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Table of Contents Pre-Installation Information...2 Physical Dimensions...4 Rough-In Dimensions...5 Hardware Identification Chart...6 Installation Instructions...7 Step 1:

More information

FC 5 FC 5 Premium. OPERATOR MANUAL Floor Cleaner...2 MANUAL DE USUARIO Limpiador de piso...22 MANUEL D UTILISATION Nettoyant pour sols...

FC 5 FC 5 Premium. OPERATOR MANUAL Floor Cleaner...2 MANUAL DE USUARIO Limpiador de piso...22 MANUEL D UTILISATION Nettoyant pour sols... FC 5 FC 5 Premium OPERATOR MANUAL Floor Cleaner.................2 MANUAL DE USUARIO Limpiador de piso............22 MANUEL D UTILISATION Nettoyant pour sols...........44 59682960 2018.03 FLOOR CLEANER

More information

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Specifications / Parts & Contents...

More information

Model: SF-450 PROFESSIONAL STYLE STEAMER

Model: SF-450 PROFESSIONAL STYLE STEAMER Model: SF-450 PROFESSIONAL STYLE STEAMER IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed including the following: 1. Read all instructions. 2.

More information

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea

KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea TM TM www.klaudio.com KD-CLN-LP200 Ultrasonic Vinyl Record Cleaner User s Manual English v1.2 Printed in Korea s are updated regularly. Please be sure to check our support page for a newer version of this

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual Outdoor Bottle Fillers Table of Contents Pre-Installation Information...2 Physical Dimensions...4 Rough-In Dimensions...5 Hardware Identification Chart...6 Installation

More information

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10 INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD,

More information

OWNER S MANUAL. 4 GALLON OUTPUT PER DAY COOL MOISTURE HUMIDIFIER Model HCM-2051 Series. * Output dependent on room temperature and humidity.

OWNER S MANUAL. 4 GALLON OUTPUT PER DAY COOL MOISTURE HUMIDIFIER Model HCM-2051 Series. * Output dependent on room temperature and humidity. OWNER S MANUAL 4 GALLON OUTPUT PER DAY COOL MOISTURE HUMIDIFIER Model HCM-2051 Series * Output dependent on room temperature and humidity. IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS

More information

Manual update 2016 MC37/MFC3600

Manual update 2016 MC37/MFC3600 Manual update 2016 MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You

More information

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0040A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...

More information

OWNER S MANUAL COOL MOISTURE HUMIDIFIER 1.25 GALLON (4.7 LITERS) OUTPUT PER DAY* RCM-832N. *Output dependent on room temperature and humidity.

OWNER S MANUAL COOL MOISTURE HUMIDIFIER 1.25 GALLON (4.7 LITERS) OUTPUT PER DAY* RCM-832N. *Output dependent on room temperature and humidity. OWNER S MANUAL COOL MOISTURE HUMIDIFIER 1.25 GALLON (4.7 LITERS) OUTPUT PER DAY* RCM-832N *Output dependent on room temperature and humidity. IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.35 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

English. Your Model Number is: HD1500 IMPORTANT

English. Your Model Number is: HD1500 IMPORTANT Your Model Number is: HD1500 IMPORTANT Attention Valued Customer: The serial number of your machine and date of purchase is necessary information to facilitate warranty claims and the ordering of replacement

More information

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK   - website: V-027P Rapide Pet User Guide 10/7/07 10:05 Page 14 EEC STATEMENT OF COMPLIANCE Manufacturer/EEC importer: VAX Limited, hereby on our own responsibility declare that the products V-027/V-027PT/V-027P/CCW-701

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.75 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

Manual for MC37/MFC3600

Manual for MC37/MFC3600 Manual for MC37/MFC3600 SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel

More information

ULTRASONIC DIGITAL HUMIDIFIER Instruction Manual and Warranty Information IM0002A READ AND SAVE THESE INSTRUCTIONS

ULTRASONIC DIGITAL HUMIDIFIER Instruction Manual and Warranty Information IM0002A READ AND SAVE THESE INSTRUCTIONS ULTRASONIC DIGITAL HUMIDIFIER Instruction Manual and Warranty Information IM0002A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...

More information

S3501 N2 S3501BB N OWNER S GUIDE

S3501 N2 S3501BB N OWNER S GUIDE WWW.SHARKCLEAN.COM S3501 N2 S3501BB N OWNER S GUIDE S3501_N2_S3501BB_N_11_IB_ENG_111020_2.indd 1 IMPORTANT SAFETY INSTRUCTIONS For Household Use Only WHEN USING YOUR SHARK STEAM MOP, BASIC SAFETY PRECAUTIONS

More information

16 OUTDOOR MISTING FAN

16 OUTDOOR MISTING FAN 16 OUTDOOR MISTING FAN Model: SF-1670M READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USE IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to

More information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE. Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

2.1 GALLON/ 7.56 LITER ULTRASONIC HUMIDIFIER

2.1 GALLON/ 7.56 LITER ULTRASONIC HUMIDIFIER 2.1 GALLON/ 7.56 LITER ULTRASONIC HUMIDIFIER MODEL# EE-864 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS APPLIANCE. TABLE OF CONTENTS Table of Contents P.1 Important

More information

Murano Shower Cabin Installation Instruction

Murano Shower Cabin Installation Instruction Murano Shower Cabin Installation Instruction IMPORTANT Please read carefully the following instructions before installing your shower cabin. If you have any questions on this shower cabin installation

More information

S3501SP N2 OWNER S GUIDE

S3501SP N2 OWNER S GUIDE WWW.SHARKCLEAN.COM S350SP N OWNER S GUIDE IMPORTANT SAFETY INSTRUCTIONS For Household Use Only WHEN USING YOUR SHARK STEAM MOP, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

More information

PERSONAL Ultrasonic Cool Mist Humidifier

PERSONAL Ultrasonic Cool Mist Humidifier PERSONAL Ultrasonic Cool Mist Humidifier FOR MODEL: EE-5951 If you have any questions about the operation of your humidifier, please contact Crane Customer Care. Toll Free: 888-599-0992 Email: customer-service@crane-usa.com

More information

Manual for MC21A SETUP INSTRUCTIONS

Manual for MC21A SETUP INSTRUCTIONS Manual for MC21A SETUP INSTRUCTIONS Evaporative cooling works on the principle of heat absorption by moisture evaporation. Simply put, heat is removed from the air as water evaporates. You feel this principle

More information

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ: User Guide Vax Careline: AU: 1300 361 505 NZ: 0800 800 900 Carpet Washer Get Cleaning... What s your Vax s model number? W8 W8 W0 W0 W0 W W W W W What s your serial number? (Located on the base of the

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA G-Series Cooler UPRIGHT COOLER Part No.11IPA-062800 Instruction Manual FOR YOUR FUTURE REFERENCE Thank you for using our product. This manual will guide you in getting the best use of your cooler. Remember

More information

Operating Manual for Profident / Profident PLUS

Operating Manual for Profident / Profident PLUS Operating Manual for Profident / Profident PLUS Content: 1. Accessories... 1 2. First Steps... 2 2.1 Air Pressure... 2 2.2 Positioning of the Handpieces... 2 2.3 Pressurised Water Bottle... 3 2.3.1 Refill

More information

Garment Steamer Model SC620

Garment Steamer Model SC620 OWNER S MANUAL Garment Steamer Model SC620 For information or assistance: EURO-PRO Corporation 178 West Service Rd. Champlain, NY 12919 1-800-798-7398 www.euro-pro.com IMPORTANT SAFETY INSTRUCTIONS When

More information

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET 1 INDEX 1 TECHNICAL DATA 2 TEMPERATURE ALTERNATIVES 3 PACK CONTENTS 4 PRE-INSTALLATION INFO 5-6 FAUCET INSTALLATION 7 ADJUSTING

More information

01694-REVC_081315_ENGLISH

01694-REVC_081315_ENGLISH 01694-REVC_081315_ENGLISH MODEL: CSP EZ-CREAM TM 3/8 OUNCE, CHICK-FIL-A 120V Series 14I 94152 SAFETY GUIDELINES WHEN USING THIS UNIT: C Warning- E Electrical shock could occur: This unit must be earthed

More information

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A CLEAN MIST DUAL TANK SMART HUMIDIFIER Tabletop & Floor Standing Instruction Manual and Warranty Information IM0036A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications...

More information

Operations and Safety Manual

Operations and Safety Manual Tuffy Jr. Heated Soil Extractor Operations and Safety Manual BEFORE YOU START: SAFETY OPERATION SERVICE PARTS TROUBLESHOOTING RETURN GOODS POLICY! READ and UNDERSTAND this material before operating or

More information

TOUCHDOWN 48 CEILING FAN

TOUCHDOWN 48 CEILING FAN TOUCHDOWN 48 CEILING FAN MODEL #50205 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am

More information

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER PERSONAL COOL MIST ULTRASONIC HUMIDIFIER MODEL # EE-5949 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFCTIVE USE OF THIS APPLIANCE. TABLE OF CONTENTS Table of Contents P. 1 Safety Instructions

More information

ADORABLE Ultrasonic Cool Mist Humidifier

ADORABLE Ultrasonic Cool Mist Humidifier ADORABLE Ultrasonic Cool Mist Humidifier FOR MODELS: EE-865, EE-3186, EE-3189, EE-3190, EE-3191, EE-4139, EE-4140, EE-5058, EE-6369, EE-7270, EE-8189, EE-8190, EE-8243, EE-8245, EE-8246, EE-8247, EE-8248,

More information

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE: CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE: 1-866-902-9690 8:00 am to 5:00 pm, C.S.T., Monday - Friday www.forcetoolsusa.com TABLE OF CONTENTS

More information

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how

More information

Cool Mist Ultrasonic Humidifier

Cool Mist Ultrasonic Humidifier Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information HUM-CM50 IMPORTANT SAFETY INSTRUCTIONS: WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS

More information

Vax Careline: Instruction Manual. Vax Model Number V-029 Vax Model Number V-029Q

Vax Careline: Instruction Manual. Vax Model Number V-029 Vax Model Number V-029Q www.vax.co.uk Vax Careline: 0870 6061248 Vax Model Number V-029 Vax Model Number V-029Q Please read carefully before using the washer. Always fully extend the mains cable before use. Instruction Manual

More information

SPOTCLEAN PRO SERIES USER GUIDE 3624, 2458

SPOTCLEAN PRO SERIES USER GUIDE 3624, 2458 SPOTCLEAN PRO SERIES USER GUIDE 3624, 2458 IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING YOUR PORTABLE DEEP CLEANER. When using an electrical appliance, basic precautions should be observed,

More information

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times USER MANUAL MODELS: COX 115V-N COX 220V-N COX 115V-R COX 220V-R 2364 Leicester Road, P.O. Box 175, Leicester, NY 14481 Phone (585)

More information

Multi-Cyclonic Vacuum USER GUIDE

Multi-Cyclonic Vacuum USER GUIDE Multi-Cyclonic Vacuum USER GUIDE MODEL CJTG00499B-120 Thank you for purchasing a BENNETT READ POWER UP PET vacuum. Your POWER UP PET vacuum incorporates the latest technological advances in home cleaning

More information

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz Energy- Saving Mode Portable AC 10,000 BTU Model: MW-L3-10C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday 1 888 557 3848 Instruction Manual

More information

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Owner s Manual READ AND SAVE THESE INSTRUCTIONS 16 Outdoor Misting / Oscillating Fan Model Number: AMMF16R-1 Owner s Manual READ AND SAVE THESE INSTRUCTIONS CAUTION: Before using this product, read this manual and follow all safety rules and operating

More information

DOUBLE DISHDRAWER TM DISHWASHER

DOUBLE DISHDRAWER TM DISHWASHER DOUBLE DISHDRAWER TM DISHWASHER DD4DDFT & DD4DVT models INSTALLATION GUIDE US CA 5985 A 08.7 SAFETY AND WARNINGS! WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse

More information

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS 1.0 General Page 01 2.0 Description 01 3.0 Set-Up 01 4.0 Model 5462 03 4.2

More information

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4 DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4 Congratulations on your purchase of an Aquaport Executive Filtered Water Cooler This unit is easy to install and provides great tasting chilled

More information

Artizan Ortho-Pedo Bench Installation / User Manual

Artizan Ortho-Pedo Bench Installation / User Manual Artizan Ortho-Pedo Bench Installation / User Manual Applies to Models: PB250-L PB250-R Special Tools: Level 3/8 Masonry drill bit 9/32 Wood drill bit Language of origin: English vv If applicable, Midmark

More information

STEAM MOP INSTRUCTION MANUAL CATALOG NUMBER BDH1765SM PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON. SAVE THIS MANUAL FOR FUTURE REFERENCE.

STEAM MOP INSTRUCTION MANUAL CATALOG NUMBER BDH1765SM PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON. SAVE THIS MANUAL FOR FUTURE REFERENCE. STEAM MOP INSTRUCTION MANUAL CATALOG NUMBER BDH1765SM Thank you for choosing BLACK+DECKER! PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON. SAVE THIS MANUAL FOR FUTURE REFERENCE. SAFETY GUIDELINES

More information

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to For How-To videos, go to Sections marked with this video icon have more information online. BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS

More information

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM: Get ready to deep clean! Pressure Washer Montgomery Ward Customer Service 3650 Milwaukee Street, Madison, WI 53714 8:00 am to Midnight, Monday through Friday Wards.com Instruction Manual ITEM: 751821 Wards.com

More information

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056 MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL Call 888.896.8786 Model #: H056 IMPORTANT SAFE T SAVE THESE INSTRUCTIONS When using an electrical appliance, basic safety precautions should always be observed,

More information

Model HD 3501 Part No High Pressure Washer Operator Manual

Model HD 3501 Part No High Pressure Washer Operator Manual 0 15 25 40 25 Nozzle Identification SOAP HD3501 Manual 4/22/02 6:57 PM Page 1 Model HD 3501 Part No. 1.810-999.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2

More information

Optimax Refrigerated Retail Merchandisers

Optimax Refrigerated Retail Merchandisers V Optimax Refrigerated Retail Merchandisers MODEL NUMBERS RMR65E/SMR65ECT RMR100E/SMR100ECT RMR130E/SMR130ECT RMR65S RMR100S RMR130S RMR65SW RMR100SW RMR130SW RMR65SP RMR100SP RMR130SP Assisted service

More information

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series Page SUMMIT SPECIALTY APPLIANCES DIV. USE AND CARE GUIDE COMBINATION KITCHENS C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series If you need service or call with a question,

More information

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz Energy- Saving Mode Portable AC 8,000 BTU Model: MW-O-08C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF INSTRUCTIONS FOR OPERATION AND CARE OF LITTLE Splint Compact Splint Pan Model LS-1 Whitehall Manufacturing is a Member of Acorn Engineering s Family of Companies. 6900-191-001 July 2010 Introduction...3

More information

01550-RevG IMPORTANT INSTRUCTIONS WEBSITE MANUAL

01550-RevG IMPORTANT INSTRUCTIONS WEBSITE MANUAL 01550-RevG-082712 IMPORTANT INSTRUCTIONS WEBSITE MANUAL english model: FSAF Food Server Advantage TM Fudge/Caramel 120V Series 12A 85070 Unit Set-Up Always clean unit thoroughly before first use. See UNIT

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL ADU-10CF (NSN: 6520-01-456-7170) Part 1 of 2 P.O. Box 1548 Woodinville, WA 98072-1548 1-800-426-5913 * 425-487-3157 * Fax: 425-487-2608 email: info@aseptico.com * Internet:

More information

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions Please read this manual completely prior to installing and operating this equipment. This manual describes how to install,

More information

ULTRASONIC HUMIDIFIER

ULTRASONIC HUMIDIFIER To Buy: Visit www.sylvane.com or call (800) 934-9194 For Product Support: Contact Sunpentown at 1-800-330-0388 ULTRASONIC HUMIDIFIER [ADORABLE MONKEY] To prolong the life of this humidifier, using distilled

More information

HydroFlux Welder Torch System T0-102 / T0-103

HydroFlux Welder Torch System T0-102 / T0-103 HydroFlux Welder Torch System T0-102 / T0-103 Setting Up The HydroFlux 1. Location - The HydroFlux Welder must be placed on a level surface with adequate ventilation. We recommend a minimum of 4 inches

More information

Lifetime Limited Warranty

Lifetime Limited Warranty Hampton Bay Lifetime Limited Warranty The retailer warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date

More information

Professional Warming Drawer and Warming Drawer Cabinet

Professional Warming Drawer and Warming Drawer Cabinet Professional Warming Drawer and Warming Drawer Cabinet Care & Use/Installation Instructions Models: (C)VQEWD5300SS (C)VQEWD5420SS IMPORTANT SAFETY INSTRUCTIONS WARNING: Read this manual carefully and completely

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL CHIP WARMERS MODELS: 500-CW 700-CW 500-CW-EX (New 2014) 700-CW-EX (New 2014) INSTALLATION & OPERATION MANUAL For additional information on WITTCO or to locate an authorized parts and service provider in

More information

ELSTON 52 CEILING FAN

ELSTON 52 CEILING FAN ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -

More information

Portable Air Conditioner

Portable Air Conditioner Owner s Manual Portable Air Conditioner Model PCMB-12000E / PCMB-12000EH It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in

More information

POWERCLEAN. Vacuum USER GUIDE 1305, 1306, 1645, 1646, 1647 SERIES. For How-To videos, go to

POWERCLEAN. Vacuum USER GUIDE 1305, 1306, 1645, 1646, 1647 SERIES. For How-To videos, go to POWERCLEAN Vacuum USER GUIDE 1305, 1306, 1645, 1646, 1647 SERIES For How-To videos, go to Sections marked with this video icon have more information online. IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS

More information