ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

Size: px
Start display at page:

Download "ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)"

Transcription

1 ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) Models: NXS SERIES: (50, 85, 110, 145, 175, 200) (N5/L5) or (N7/L7)!INSTALLER: This manual is the property of the owner. Please present this manual to the owner when you leave the job site. WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. IF YOU SMELL GAS: FOR YOUR SAFETY DO NOT try to light any appliance. DO NOT touch any electrical switch; DO NOT use any telephone in your building. IMMEDIATELY call your gas supplier from a neighbor's telephone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.!important: SAVE THIS MANUAL FOR FUTURE REFERENCE. SPACE-RAY Post Office Box (28236) 305 Doggett Street (28203) Charlotte, North Carolina Phone (704) Fax (704) info@spaceray.com Feb 2015

2 TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1.0) Typical Suspension Methods ) NXS SERIES SPECIFICATIONS ) NXS SERIES PACKING LIST ) NXS SERIES DIMENSIONS ) NXS SERIES - HEATER ASSEMBLY OVERVIEW ) NXS SERIES - HEATER ASSEMBLY ) NXS SERIES - ATTACHING CONTROL BOX ASSEMBLY ) NXS SERIES - ATTACHING DRAFT INDUCER ASSEMBLY ) NXS SERIES - MULTIPLE DRAFT INDUCER POSITIONS This heater complies with ANSI Z83.20 (current standard) and CSA Copies of the National Fuel Gas Code (ANSI Z223.1-latest edition) are available from the CSA at 8501 East Pleasant Valley Road, Cleveland, Ohio or 55 Scarsdale Road, Don Mills, Ontario M3B 2R3. All NFPA codes are available from the National Fire Protection Association, Batterymarch Park, Quincy, Massachusetts This product can expose you to chemicals including ceramic fibers, which are known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to Jan

3 1.0) TYPICAL SUSPENSION METHODS Various means of suspending the heater can be used. See the following drawings for typical examples. 1. Use only noncombustible materials for suspending hangers and brackets. 2. A minimum No. 2 chain with a working load limit of 115 lbs. is required. 3. Turnbuckles can be used with chains to allow leveling of the heater. All S hooks and eye bolts must be manually crimped closed by the installer. 4. When using rigid means for heater suspension (rod, flat bar, etc.) provide sufficient lengths or swing joints to compensate for expansion. See Figures b and c. 5. Heaters subject to vibration must be provided with vibration isolating hangers. 6. Heaters must not be supported by gas or electric supply lines and must be suspended from a permanent structure with adequate load capacity. Space-Ray recommends that the body sections be suspended using chains with turnbuckles. This will allow slight adjustments after assembly and heater expansion/ contraction during operation. If a trapeze method is used for tube support/hanger brackets (shown below), the minimum chain length for the two connecting chains is 36 to minimize any vibration that might be generated by the draft inducer assembly. If these chains must be less than 36, then do not use the trapeze method and, instead, use individual chains on each tube support/hanger bracket. Jan

4 2.0) NXS SERIES SPECIFICATIONS Btu/hr (2 stage) Btu/hr Flue Restrictor Orifice Size Minimum * Mounting Height Model No. High Input Low Input Plate I.D. & Part # Natural Gas Propane Horizontal Turbulator Qty. NXS 50 50,000 32,500 1 # #29 (0.136) #47 (0.079) 12 ft. 5 NXS 85 85,000 50, /16 # mm (0.165) 2.5mm (0.098) 13 ft. 7 NXS ,000 71, /2 # mm (0.197) #32 (0.116) 15 ft. 7 NXS ,000 88, /8 # mm (0.224) #29 (0.136) 18 ft. 9 NXS , , /8 # E (0.250) #26 (0.147) 19 ft. 3 NXS , , /4 # G (0.261) 5/32 (0.156) 21 ft. 2 * This chart is intended as a guide only, as heaters may be mounted at various heights. MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform energy distribution for complete building applications. Please consult your local Space-Ray Representative for a detailed analysis of your particular infrared heating requirements. Model Identification: Control Option Suffix Gas Type Description N5 Natural Single Stage Gas Valve Single Stage Input L5 Propane Single Stage Gas Valve Single Stage Input N7 Natural Two Stage Gas Valve Modulating Input High/Low Fire L7 Propane Two Stage Gas Valve Modulating Input High/Low Fire Gas Pipe Connection Tube Diameter Flue Connection Fresh Air Connection Electrical Supply Current Rating ½ MPT (Male) 4 4 Round 4 Round 120 Volt, 60Hz, 1 Phase 2.6 Amp Fuse Rating: In-line: 2 Amp 250V (for 24V Circuit) Ignition System (direct spark): 30 second pre-purge period 3.0) NXS SERIES PACKING LISTS Control/Draft Inducer Package Part Description QTY Control Box Assembly... 1 Draft Inducer & Junction Box Assembly w/flue Restrictor Plate Starting Collar (# )... 1 Control Fastener Kit (# )... 1 Containing: #8-32 Screws & Nuts (# & # )... 2 ¼ - 20 Locknuts (# )... 6 Tube Flange Gasket (# )... 2 Installation & Operation Instructions Part A (# )... 1 Installation & Operation Instructions Part B (# )... 1 Installation & Operation Instructions General (# )... 1 Gas connector, 5/8 OD x 36 (# )... 1 Turbulator 24 Long (# ) See chart above for required quantities NXS SERIES CONTROL/DRAFT INDUCER PACKAGE NUMBERS SINGLE STAGE CONTROLS TWO STAGE CONTROLS MODEL NO. PART NO. GAS TYPE MODEL NO. PART NO. GAS TYPE NXS 50-N5 # NXS 50-L5.# NXS 85-N5...# NXS 85-L5.# NATURAL PROPANE NATURAL PROPANE NXS 50-N7.# NXS 50-L7.# NXS 85-N7... # NXS 85-L7.# NATURAL PROPANE NATURAL PROPANE NXS 110-N5... # NXS 110-L5..# NATURAL PROPANE Jan NXS 110-N7... # NXS 110-L7..# NATURAL PROPANE

5 SINGLE STAGE CONTROLS TWO STAGE CONTROLS MODEL NO. PART NO. GAS TYPE MODEL NO. PART NO. GAS TYPE NXS 145-N5...# NXS 145-L5..# NATURAL PROPANE NXS 145-N7... # NXS 145-L7..# NATURAL PROPANE NXS 175-N5...# NXS 175-L5. # NXS 200-N5...# NXS 200-L5.# NATURAL PROPANE NATURAL PROPANE NXS 175-N7... # NXS 175-L7. # NXS 200-N7... # NXS 200-L7.# NATURAL PROPANE NATURAL PROPANE NXS50 Body Packing List (complete system) (Package Part Number is indicated on the outside of each corresponding carton.) Systems Body Package Descriptions 15 Ft. System 15 Ft. Pkg Ref. No. Part No. Each Body Package Includes: Qty Ft. Steel Tube with (two) 6 Hole Flanges (ATC) Ft. Steel Tube with (one) 12 Radial Hole Flange (ALC) Reflector, Main Body 13 Wide x Long Reflector, Main Body 13 Wide x 59.5 Long Reflector End Cap - Notched Tube Flange Assembly Hardware kit NXS50 comprising: Tube Hanger/Support Bracket U Bolt Clamp-4"OD Gasket, Tube Side Panel Holder Bracket Reflector Spacer Bracket Side Panel 1 3/ Side Panel 6 1/ Side Panel Kit NXS50 comprising: Side Panel Fastener Kit-NXS 50 comprising: Screw, #10-24 x ½ Round Head Machine Nut, Hex 5/16-18 SS Nut, Hex ¼-20 Keps Locknut SS Screw, ¼-20 x 5/8 Hex Washer Head Machine SS Clamp, Reflector Locking Screw, #10-16 x 5/8 Self-Drill (TEKS) 40 Jan

6 NXS85 Body Packing List (complete system) (Package Part Number is indicated on the outside of each corresponding carton.) Systems Body Package Descriptions 20 Ft. System 20 Ft. Pkg Ref. No. Part No. Each Body Package Includes: Qty Ft. Steel Tube with (two) 6 Hole Flanges (ATC) Ft. Steel Tube with (one) 12 Radial Hole Flanges (ALC) Reflector, Main Body 13 Wide x Long Reflector End Cap - Notched Tube Flange Assembly Hardware kit NXS85 comprising: Tube Hanger/Support Bracket U Bolt Clamp-4"OD Gasket, Tube Side Panel Holder Bracket Reflector Spacer Bracket Side Panel 1 3/ Side Panel 3 7/ Side Panel Kit NXS85 comprising: Side Panel Side Panel Fastener Kit-NXS 85 comprising: Screw, #10-24 x ½ Round Head Machine Nut, Hex 5/16-18 SS Nut, Hex ¼-20 Keps Locknut SS Screw, ¼-20 x 5/8 Hex Washer Head Machine SS Clamp, Reflector Locking Screw, #10-16 x 5/8 Self-Drill (TEKS) 40 Jan

7 NXS110 Body Packing List (complete system) (Package Part Number is indicated on the outside of each corresponding carton.) Systems Body Package Descriptions 30 Ft. System 30 Ft. Pkg Ref. No. Part No. Each Body Package Includes: Qty Ft. Steel Tube with (two) 6 Hole Flanges (ATC) Ft. Steel Tube with 12 Radial Hole Flange (ALC) Ft. Steel Tube less Flanges (ALC) Reflector, Main Body 13 Wide x Long Reflector, Main Body 13 Wide x 24 Long Tube Coupling Reflector End Cap - Notched Tube Flange Assembly Hardware kit NXS110 comprising: Tube Hanger/Support Bracket U Bolt Clamp-4"OD Gasket, Tube Side Panel Holder Bracket Reflector Spacer Bracket Side Panel 1 3/ Side Panel 3 7/ Side Panel Side Panel Kit NXS110 comprising: Side Panel Side Panel Fastener Kit-NXS110 comprising: Screw, #10-24 x ½ Round Head Machine Nut, Hex 5/16-18 SS Nut, Hex ¼-20 Keps Locknut SS Screw, ¼-20 x 5/8 Hex Washer Head Machine SS Clamp, Reflector Locking Screw, #10-16 x 5/8 Self-Drill (TEKS) 67 Jan

8 NXS145 Body Packing List (complete system) (Package Part Number is indicated on the outside of each corresponding carton.) Systems 40 Ft. System Body Package Descriptions 20 Ft. Pkg. 1 of Ft. Pkg. 2 of Ref. No. Part No. Each Body Package Includes: Qty. Qty Ft. Steel Tube with (two) 6 Hole Flanges (ATC) Ft. Steel Tube with 12 Radial Hole Flange (ALC) Ft. Steel Tube less Flanges (ALC) Reflector, Main Body 13 Wide x Long Reflector, Main Body 13 Wide x 24 Long Tube Coupling Reflector End Cap - Notched Tube Flange Assembly Hardware kit NXS145 comprising: Tube Hanger/Support Bracket U Bolt Clamp-4"OD Gasket, Tube Side Panel Holder Bracket Reflector Spacer Bracket Side Panel 1 3/ Side Panel Side Panel Kit NXS145 comprising: Side Panel Side Panel Fastener Kit-NXS145 comprising: Screw, #10-24 x ½ Round Head Machine Nut, Hex 5/16-18 SS Nut, Hex ¼-20 Keps Locknut SS Screw, ¼-20 x 5/8 Hex Washer Head Machine SS Clamp, Reflector Locking Screw, #10-16 x 5/8 Self-Drill (TEKS) 80 Jan

9 NXS175 Body Packing List (complete system) (Package Part Number is indicated on the outside of each corresponding carton.) Systems 50 Ft. System Body Package Descriptions 20 Ft. Pkg. 1 of Ft. Pkg. 2 of Ref. No. Part No. Each Body Package Includes: Qty. Qty Ft. Steel Tube with (two) 6 Hole Flanges (ATC) Ft. Steel Tube with 12 Radial Hole Flange (ALC) Ft. Steel Tube less Flanges (ALC) Reflector, Main Body 13 Wide x Long Reflector, Main Body 13 Wide x 24 Long Tube Coupling Reflector End Cap - Notched Tube Flange Assembly Hardware kit NXS175 comprising: Tube Hanger/Support Bracket U Bolt Clamp-4"OD Gasket, Tube Side Panel Holder Bracket Reflector Spacer Bracket Side Panel 1 3/ Side Panel Side Panel Kit NXS175 comprising: Side Panel Side Panel Fastener Kit - NXS175 comprising: Screw, #10-24 x ½ Round Head Machine Nut, Hex 5/16-18 SS Nut, Hex ¼-20 Keps Locknut SS Screw, ¼-20 x 5/8 Hex Washer Head Machine SS Clamp, Reflector Locking Screw, #10-16 x 5/8 Self-Drill (TEKS) 90 Jan

10 NXS200 Body Packing List (Complete System) (Package Part Number is indicated on the outside of each corresponding carton.) Systems 60 Ft. System Body Package Descriptions 30 Ft. Pkg. 1 of Ft. Pkg. 2 of Ref. No. Part No. Each Body Package Includes: Qty. Qty Ft. Steel Tube with (two) 6 Hole Flanges (ATC) Ft. Steel Tube with 12 Radial Hole Flange (ALC) Ft. Steel Tube less Flanges (ALC) Reflector, Main Body 13 Wide x Long Reflector, Main Body 13 Wide x 36 Long Tube Coupling Reflector End Cap - Notched Tube Flange Assembly Hardware kit NXS200 comprising: Tube Hanger/Support Bracket U Bolt Clamp-4"OD Gasket, Tube Side Panel Holder Bracket Reflector Spacer Bracket Side Panel 1 3/ Side Panel 3 7/ Side Panel Side Panel Kit NXS200 comprising: Side Panel Fastener Kit-NXS200 comprising: Screw, #10-24 x ½ Round Head Machine Nut, Hex 5/16-18 SS Nut, Hex ¼-20 Keps Locknut SS Screw, ¼-20 x 5/8 Hex Washer Head Machine SS Clamp, Reflector Locking Screw, #10-16 x 5/8 Self-Drill (TEKS) 90 Jan

11 4.0) NXS SERIES DIMENSIONS Jan

12 5.0) NXS SERIES - HEATER ASSEMBLY OVERVIEW Jan

13 Jan

14 Jan

15 Jan

16 Jan

17 Jan

18 6.0) NXS SERIES HEATER ASSEMBLY During field assembly of the NXS series heater body sections, the recommended procedure is as follows: 1. Before hanging heater sections, first determine the actual layout of the system. See Section 4.0 for complete heater dimensions. Consideration must also be taken for flue pipe, fresh air ducting, gas piping, clearances to combustibles, etc. before hanging heater. 2. Put the suspension in place using proper suspension methods (see Typical Suspension Methods in Section Hang each tube section individually. Observe the following requirements. a) DO NOT attach the heater tube sections together on the ground and attempt to hang the entire system. The weight of the individual heater body sections can cause misalignment and damage to the heater. b) DO NOT relocate the tube support/hanger brackets, especially at the control end of the heater. c) For all NXS Models, the first tube section MUST be a 10 ft. (ATC steel) tube with one 6-hole flange which is to mount burner control box. d) For all NXS models, the last tube section MUST be a 10 ft. (ALC steel) tube without a flange at the draft inducer end. A separate tube flange assembly (supplied in body package) is used to mount the draft inducer. e) For all NXS models, the middle section tubes are all 10 ft. (ALC steel) with or without (model dependent) hole flanges. f) Failure to attach the control box to the flange end as indicated above will void the manufacturer s warranty. g) Any S hooks used in suspension should be crimped close. Jan

19 A. SUSPENSION - SPACING DIMENSIONS - NXS 1. Install the suspension spaced at dimensions shown below and using proper suspension methods (see Typical Suspension Methods in Section 5.0 of Part A.) Jan

20 B. TYPICAL ASSEMBLY LAYOUTS (with turbulators) - NXS MODEL EMITTER TUBE LENGTH SYSTEM LENGTH 2 Ft. Turbulator (each leg) Sections NXS 50 NXS Ft. (2 each) 20 Ft Ft./5 Ft (1 each) 15 Ft. 5 NXS Ft. (3 each) 30 Ft. 7 NXS Ft. (4 each) 40 Ft. 9 NXS Ft. (5 each) 50 Ft. 3 NXS Ft. (6 each) 60 Ft. 2 NOTES: 1. In all configurations, the control unit must be connected directly to the ATC steel body section having a 6 hole flange. Jan

21 C. JOIN TUBE SECTIONS - COUPLING DETAILS (second, third and fourth tube joints only) 1. Join the 10ft tube sections together and secure with tube couplings as follows: The following coupling tightening instructions MUST be followed properly to ensure the integrity of the tube connections. Two #10 self-drilling screws MUST be installed at every coupling as shown in the instructions below. Failure to do so may result in serious injury or property damage. 1) Place the compression coupling over the end of the tube. 2) Use the small hole at the centerline of the coupling to check that the coupling is inserted correctly. 3) Partially tighten the bolt nearest the end of the tube (approximately half closed). 4) Slide the next tube into the coupling. 5) Make sure both tube ends are butted together. 6) Finish tightening both bolts to ft. lbs. torque to ensure a complete seal. 7) Use the two Self-drilling screws through the pre-punched holes to secure the tubes in the coupling. 8) Check to ensure that the hardware is completely closed and the band is seated on the reaction block and interference pins as illustrated above. 9) Once all the heater body sections are attached, make sure that the heater system is level. If it is not, slight adjustments can be made using the turnbuckles. (See Typical Suspension Methods in Section 5.0 of Part A.) Important: NEVER reuse a coupling. Always install a new coupling only and torque as per instructions above and the diagrams above. Jan

22 D. HANGING THE TUBE SECTIONS 1. Space the hanger brackets according to the suspension dimensions above for the first tube section. Note: The distances are measured from center of the holes of each support/hanger bracket. a) Place tubes over the hanger brackets with the welded seam facing down toward the ground. Failure to assemble the tube with the seam facing down will void the manufacturer s warranty. b) Secure the tubes to each support/hanger bracket using U-bolt clamps and 5/16-18 nuts provided. 2. Raise the tube section up to the suspension chain (or other methods), using S hooks to attach the tube support brackets (close S hooks after they are attached to the hanger brackets). Hang each tube section individually. DO NOT attach all of the heater tube sections together on the ground and attempt to hang the entire system. Jan

23 3. Suspend the hanger bracket for the second section of tube, raise the tube into position and join the tube sections together using ¼-20 screws, locknuts and gasket shown below. Fasten the tube to the hanger bracket. Jan

24 4. Suspend the remaining hanger brackets for the third, fourth and fifth (model dependent) section of tubes. Raise each tube into position and join them together using tube couplings as described above in Join Tube Sections - Coupling Details. Fasten each tube to the hanger brackets as above. NOTE: The last tube will have a 12 radial hole flange to mount the draft inducer assembly. E. ADD LOWER REFLECTOR 1. Position the lower reflectors over the tube support/hanger brackets. Arrange the reflector panels to the dimensions shown in the table and figures below. The reflectors MUST be positioned in accordance with the dimensions stated because the side panels provided with the heater are designed to cover the entire length of the reflectors and therefore if the location of the reflectors does not match these dimensions then the side panels will not fit. See table and figure below: Model A R1 O1 R2 O2 R3 O3 R4 O4 R5 O5 R6 RO6 R7 NXS 15ft N/A N/A N/A N/A N/A N/A N/A N/A N/A NXS 20ft N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NXS 30ft N/A N/A N/A N/A N/A N/A NXS 40ft N/A N/A N/A N/A NXS 50ft N/A N/A NXS 60ft All Dimensions in inches. Jan

25 Secure the lower reflector panels to the support brackets using the locking clamps. It is important to only secure the reflectors in the locations shown below. The first and second lower reflectors must be able to move freely at the overlap. a) From the underside of the hanger bracket drive in the sheet metal screw until the tip is just through the reflector panel. b) Position the reflector locking clamp PN (from the fastener pack) over the screw. c) Continue to drive the screw until the reflector is secured in place using a low torque driver. d) Repeat this at each hanger bracket specified in figure below. Note: The reflector is NOT clamped at the second and second to last hanger bracket on every model. Jan

26 F. ATTACH REFLECTOR SPACER BRACKETS 1. Attach the reflector spacer brackets at each tube support/hanger bracket using the #10-24 machine screws supplied in fastener kit. See figure below: G. ADD UPPER REFLECTORS 1. Place the upper reflectors over each of the reflector spacer brackets. Repeat the same reflector positions and overlap dimensions as specified in table above. To align reflectors precisely to the ends of the lower reflector, hold the end cap in place against the lower reflector slide the upper reflector to rest against it. See figure below. Jan

27 H. ATTACH SIDE PANELS 1. Place side panels over the sides of both reflector panels between each tube support/hanger bracket and at the ends of the heater. See figure below. 2. Secure these in place using the side panel holder brackets and two #10 x ½ sheet metal screws supplied in the fastener kit. See figure below. NOTE: DO NOT screw into the side panels. I. ATTACH REFLECTOR END CAPS 1. Place end reflector caps and secure using screws (supplied in fastener kits) as shown in figure below: Jan

28 7.0) NXS SERIES - ATTACHING CONTROL BOX ASSEMBLY 1. Attach the control box and gasket to end of tube flange and secure with 1/4-20 locknuts. NOTE: The control box must be mounted to an ATC steel body section having a 6-hole flange. Failure to attach the control box to the flange end as indicated above will void the manufacturer s warranty. 2. A 3/8" connector is located on the left side of the control cabinet to provide strain relief for field wiring to the draft inducer junction box. Refer to Electrical Connections in the general installation and operation instructions for wiring between the control box and the draft inducer. 3. The control box must be mounted with the perforated fresh air plate on top, facing the ceiling. 4. The heater must be mounted horizontally with the control box positioned upright with the lights facing down. Failure to install the control box in an upright position will VOID the manufacturer s warranty. Jan

29 8.0) NXS SERIES - ATTACHING DRAFT INDUCER ASSEMBLY 1. Slide the draft inducer flange over the end of tube. Rotate the flange until the tightening brackets are in the upright position. Secure the flange by tightening the ¼-20 screw located on the tightening brackets. 2. Attach the draft inducer assembly and gasket to end of the draft inducer flange and secure with 1/4-20 locknuts. A flue restrictor plate is attached to the draft inducer weld studs. DO NOT DISCARD RESTRICTOR PLATE and make sure this remains in place while the draft inducer is being attached to the heater body. NOTE: The draft inducer can be mounted in a vertical, a 45º, or a horizontal position. Refer to the Multiple Draft Inducer Positions section in the instructions. 3. Disconnect the piece of SJO cable (if equipped) from the junction box and discard. This is used only on NXU series heaters. 4. The 3/8" connector used to hold the SJO cable will remain to provide strain relief for field wiring of the control box and the draft inducer. Refer to the Electrical Connections in the general installation and operation instructions. 5. If the heater is to be VENTED to the outside of the building, place the starting collar on the outlet of the draft inducer and secure with the #8-32 screws and nuts. Place the flue pipe directly onto the starting collar, secure with the #8 sheet metal screws, and terminate with an approved vent cap. 5. If the heater is for UNVENTED use, place the exhaust hood (supplied as an accessory) directly onto the outlet of the draft inducer (starting collar is not necessary for unvented use). Secure with the #8 sheet metal screws. The exhaust hood must be mounted only in an upright position and directed toward the reflector body. Jan

30 9.0) MULTIPLE DRAFT INDUCER POSITIONS The heater must be mounted horizontally. Make sure the long axis of heater is level. Multiple draft inducer positions can also be used as shown in the diagrams. This allows for the desired configuration of flue venting. Regardless of the position chosen, the junction box must remain horizontal as shown. This may be achieved as follows: 1. Remove the three (3) ¼-20 locknuts securing the motor and blower wheel assembly. 2. Pull the motor and blower wheel assembly with the motor plate slightly from the end of the housing studs. Use care not to damage the motor leads. 3. Rotate the junction box assembly to the upright position using the multi-hole mounting bracket. 4. Replace the motor and blower assembly. Tighten the locknuts. 5. Horizontal and 45º draft inducer positions can allow the plastic vacuum air tube to sag. The air tube should be shortened to prevent downward sag that could allow condensation build-up in the tube. Jan A

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Push Through System (Positive Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Push Through System (Positive Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models:

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models: INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models: (Hot Rolled Steel) (Aluminized Steel) PCS75 (N5,L5,N7,L7)

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: ADU5, ADU30, ADU35, ADU40, ADU45, ADL5, ADL30, ADL35, ADL40, ADL45 Single Stage Pull Through System (Negative Pressure) 0086

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. COLD BLOCKER

More information

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models:

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models: INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single and Two Stage Push Through System (Positive Pressure) Models: PBF 60-15 (N5, L5, N7, L7) PBF 70-15 (N5, L5, N7, L7) PBF

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Pull Through System (Negative Pressure) Models:

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Pull Through System (Negative Pressure) Models: INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Pull Through System (Negative Pressure) Models: (Hot Rolled Steel) (Aluminized Steel) CTS 80-30 CTA 80-30 CTS 100-30

More information

INSTALLATION AND OPERATION INSTRUCTIONS. RESIDENTIAL RADIANT GARAGE TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. RESIDENTIAL RADIANT GARAGE TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. RESIDENTIAL

More information

INSTALLATION AND OPERATION INSTRUCTIONS. SUNSTAR ECLIPSE INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. SUNSTAR ECLIPSE INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. SUNSTAR

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: LRU5, LRU5, LRU0, LRU5, LRU0, LRU5, LRL5, LRL5, LRL0, LRL5, LRL0, LRL5 Single Stage Pull Through System (Negative Pressure)

More information

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Push Through System (Positive Pressure) Models:

INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Push Through System (Positive Pressure) Models: INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT POULTRY TUBE HEATER Single Stage Push Through System (Positive Pressure) Models: (Hot Rolled Steel) (Aluminized Steel) PCS 75 PCA 75 PCS 100 PCA

More information

INSPECT all combustion air openings into the building and, if necessary, clear as they become blocked by litter, dust, feathers or other matter.

INSPECT all combustion air openings into the building and, if necessary, clear as they become blocked by litter, dust, feathers or other matter. INSTALLATION AND OPERATION INSTRUCTIONS INFRARED RADIANT IP55 POULTRY TUBE HEATER Single Stage Pull Through System (Negative Pressure) Models: SRLP (30, 35, 40, 45) IP55 0086 OWNER / INSTALLER: For your

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION INSTRUCTIONS. RSTP SERIES INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. RSTP SERIES INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. RSTP SERIES

More information

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED

More information

INSTALLATION AND OPERATION GENERAL INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION GENERAL INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION GENERAL INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater.

More information

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45 INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45 Single Stage Pull Through System (Negative Pressure)

More information

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS Models: PTUL 5, PTUL 0, PTUL 5, PTUL 0, PTUL 5, PTSL 5, PTSL 0, PTSL 5, PTSL 0, PTS L5 Single Stage Pull Through System (Negative Pressure)

More information

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. COLD BLOCKER

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RCH100 CONSTRUCTION HEATER FLOOR MODEL WARNING IMPROPER INSTALLATION Improper installation, adjustment, alteration, service or maintenance can

More information

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas glor sun The Original Outdoor Patio Heater Manufactured by INFRARED DYNAMICS, INC. Yorba Linda, CA 92886 U.S.A. Tel: (714) 572-4050 Fax: (714) 572-6093 Toll-Free: (888) 317-5255 www.infradyne.com SPECIFICATIONS:

More information

INSTALLATION AND OPERATION INSTRUCTIONS. SUNSTAR ECLIPSE INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. SUNSTAR ECLIPSE INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. SUNSTAR

More information

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. COLD BLOCKER INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. COLD BLOCKER

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER LTS 40 250 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED: 5-SINGLE STAGE (CHECK

More information

INSTALLATION AND OPERATION INSTRUCTIONS. RSTP SERIES INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. RSTP SERIES INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. RSTP SERIES

More information

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc. NOTICE: The information contained on the following page(s) was produced prior to May 1, 2014. On that date Reznor became part of Nortek, Inc. References to any other company affiliations are no longer

More information

OPTION CA1, CA2, AND CA3 POWER VENTERS

OPTION CA1, CA2, AND CA3 POWER VENTERS R HAZARD INTENSITY LEVELS 1. DANGER: Failure to comply will result in severe personal injury or death and/or property damage. 2. WARNING: Failure to comply could result in severe personal injury or death

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER NXU 50 200 SERIES NXS 50 200 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED:

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C PROJECT: INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS (CHECK ONE) RSTP17C NAME: ADDRESS: (CHECK ONE) PROPANE GAS DATE: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: NAME: ADDRESS: EQUIPMENT

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. MILLIVOLT

More information

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY: INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS (CHECK ONE) PROPANE GAS PROJECT: ARCHITECT/ENGINEER: NAME: ADDRESS: NAME: ADDRESS: DATE: CONTRACTOR: SUBMITTED BY: NAME: ADDRESS: EQUIPMENT

More information

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45 U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS

More information

The Economical, Unitary Infrared Heater Submittal: BH Series

The Economical, Unitary Infrared Heater Submittal: BH Series Blackheat BH The Economical, Unitary Infrared Heater Submittal: BH Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO. BH UNIT INPUT BTU/HR QTY. MODEL NO.

More information

Blackheat BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual BH-40 BH-60 BH-80 BH-100 BH-115

Blackheat BH. The Economical Unitary Infrared Heater. Installation, Operation & Service Manual BH-40 BH-60 BH-80 BH-100 BH-115 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. STARGLO

More information

INFRARED RADIANT TUBE HEATER

INFRARED RADIANT TUBE HEATER INFRARED RADIANT TUBE HEATER LTU 40 250 SERIES PROJECT: ADDRESS: ARCHITECT/ENGINEER: ADDRESS: CONTRACTOR: ADDRESS: SUBMITTED BY: N-NATURAL GAS (CHECK ONE) L-PROPANE GAS EQUIPMENT USED: 5-SINGLE STAGE (CHECK

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

INSTALLATION AND OPERATION INSTRUCTIONS. RESIDENTIAL RADIANT GARAGE TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. RESIDENTIAL RADIANT GARAGE TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. RESIDENTIAL

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

Rapid NP. Negative Pressure Unitary or Multiburner Infrared Heater. Installation, Operation & Service Manual WARNING

Rapid NP. Negative Pressure Unitary or Multiburner Infrared Heater. Installation, Operation & Service Manual WARNING FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

Low-Intensity, Infrared Heating Systems Submittal: HE Series

Low-Intensity, Infrared Heating Systems Submittal: HE Series Low-Intensity, Infrared Heating Systems Submittal: HE Series Job: Location: Engineer: Gas Specs: Date: QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT BTU/HR QTY. MODEL NO. HE UNIT INPUT

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS CSA Model98900 DRS02403 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas:

More information

INSTALLATION AND OPERATION INSTRUCTIONS. RESIDENTIAL RADIANT GARAGE TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INSTALLATION AND OPERATION INSTRUCTIONS. RESIDENTIAL RADIANT GARAGE TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure) INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. RESIDENTIAL

More information

GordonRay NP. Negative Pressure Unitary Infrared Heater. Installation, Operation & Service Manual NP-40 NP-60 NP-90 NP-125 NP-150 NP-175 NP-200

GordonRay NP. Negative Pressure Unitary Infrared Heater. Installation, Operation & Service Manual NP-40 NP-60 NP-90 NP-125 NP-150 NP-175 NP-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Leave the building. 6. Immediately

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS Printed in U.S.A. MEMBER NPGA National PROPANE GAS Association INSTALLATION AND OPERATION INSTRUCTIONS RCH100 CONSTRUCTION HEATER FLOOR MODEL WHAT TO DO IF YOU SMELL GAS *Do not try to light any appliance.

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL TWO-STAGE SAFETY CONDENSING GAS FURNACES Recognize this symbol as an indication of Important Safety Information IMPORTANT: All manufacturer products

More information

Parts List for Ener-Radiant XL Tube Heaters

Parts List for Ener-Radiant XL Tube Heaters Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. WARNING: If the information in this manual is not followed exactly, a fire

More information

Synergy WARNING FOR YOUR SAFETY. High Intensity Infrared Heaters. Installation, Service, and Maintenance Manual COMBUSTION RESEARCH CORPORATION

Synergy WARNING FOR YOUR SAFETY. High Intensity Infrared Heaters. Installation, Service, and Maintenance Manual COMBUSTION RESEARCH CORPORATION COMBUSTION RESEARCH CORPORATION Synergy High Intensity Infrared Heaters Installation, Service, and Maintenance Manual! WARNING Improper installation, adjustment, alteration, service or maintenance can

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model: 98910L Printed in China Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. WARNING: If the information in this manual

More information

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT Installation instructions for your new Spacemaker Laundry WSM2780 Gas Before you begin Read these instructions completely and carefully. IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES. Note to Installer

More information

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators Models: PSX006XL PSD008XL PSD010XL CONTENTS: Part 1 - Planning The Installation Part 2 - Securing The Blower / Ventilator Part 3 - Electrical

More information

Reflect-O-Ray Oil Fired EDS 3.5

Reflect-O-Ray Oil Fired EDS 3.5 COMBUSTION RESEARCH CORPORATION FOR YOU SAFTEY If you have a Fuel Oil leak: 1. Open windows 2. DO NOT try to light any appliance. 3. DO NOT use electrical equipment. 4. Shut off Fuel Oil supply. 5. Leave

More information

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien AMCHD36SS/ AMCHD44SS/ INDEX WARNINGS AND REQUIREMENTS... 3 RECOMMENDATIONS AND SUGGESTIONS... 6 DIMENSIONS

More information

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416)

More information

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000

More information

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models ForceRed Series Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models Solutions For Commercial & Industrial Heating, Since 1949 Pull Through Tube

More information

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS

Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO NOT try to light any appliance. 3. DO NOT use electrical switches. 4. DO NOT use any telephone in your building. 5. Extinguish any open flame. 6.

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL Serial Numbers 734000000001000-7340000000169215 OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH9B READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place

More information

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RFPA21A CONSTRUCTION HEATER FLOOR MODEL SAVE FOR FUTURE REFERENCE Space-Ray Division, Gas Fired Products, Inc. P.O. Box 36485, Charlotte, NC 28236

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

GordonRay DF. Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY

GordonRay DF. Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY GordonRay DF Installation, Operation & Service Manual DF-80 DF-100 DF-125 DF-150 DF-175 DF-200 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. DO T try to light any appliance. 3. DO T use electrical

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model99000 BRH01000 DANGER If you smell gas: 1. Shut off gas to the

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW & DOWNFLOW/HORIZONTAL CONDENSING GAS FURNACES SAFETY Recognize this symbol as an indication of Important Safety Information If not installed, operated and maintained in

More information

Using it in an enclosed space can kill you.

Using it in an enclosed space can kill you. 38 X 56 GAS FIRE PIT - OWNER S MANUAL Carlisle Chat Fire Table Base Model # 00GBC7 (6877B) Fits 6877A Carlisle Chat Fire Table Top For Propane and *Natural Gas (*See Page 7) Certified to CSA International

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS SECTION 15540 - FUEL - FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)

More information

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual

WARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual Installation, Operation, Maintenance, and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully

More information

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L Electric Wall Panel Owner s Manual & Installation Instructions 8 Element Wall Panel Front View 8 & 6 Element Wall Panel Side View 6 Element Wall Panel Back View Top 23 1 8 EWP 8 EWP 6 Bottom 17 1 4 2 3

More information

Bosch 80% AFUE Gas Furnace BGS80 Model

Bosch 80% AFUE Gas Furnace BGS80 Model Bosch 80% AFUE Gas Furnace BGS80 Model 4-Way Multipoise Category I Fan-Assisted Furnace User's Information Manual 3124627 2 Bosch 80% AFUE Gas Furnace User's Information Manual Data subject to change 06.2018

More information

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers MODELS MLS VACB20 ML-135285 VACB25 ML-710543 VACB36 ML-710544 VACB47 ML-710545 VACB60 ML-710546 VACB72 ML-135286 www.vulcanhart.com MODELS MLS

More information

CYLINDER NOT INCLUDED

CYLINDER NOT INCLUDED OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # HS125NG / MH125LP / HS125LP READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do

More information

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops Installation Guide 5 Series VGC and VGSU Built-In Gas Cooktops Table of Contents Warnings & Important Safety Instructions 3 Dimensions VGC Cooktops 6 Specifications VGC Cooktops 7 Dimensions VGSU Cooktops

More information

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2 3002239 RSIF 2014-04-04 Installation and operation manual RSIF power venter READ AND SAVE THESE INSTRUCTIONS! Product information Chapters 1 + 2 Mechanical installation Chapter 3 Electrical installation

More information

INSTALLATION / OWNER S MANUAL

INSTALLATION / OWNER S MANUAL ultraschwank Models: UHE & InfraSave Ultimate Models: EIH HIGH RADIANT OUTPUT LOW INTENSITY TUBE TYPE INFRA RED HEATER INSTALLATION / OWNER S MANUAL WARNING Improper installation, adjustment, alteration,

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH9B READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model 99000 ARL00100 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1. Shut off gas to the

More information

Owner: Keep this manual in a safe place in order to provide your service technician with the necessary information.

Owner: Keep this manual in a safe place in order to provide your service technician with the necessary information. Sunpak S34-TSH Outdoor Gas Infrared Patio Heater NOT FOR USE IN RESIDENTIAL DWELLINGS Installation, Operation and & Maintenance Instructions NOTE: Heater above shown with optional Face Trim Installer:

More information

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. Operating Instructions and Owner s Manual READ INSTRUCTIONS CAREFULLY: Read and follow all instructions.

More information

PrecisionTemp Shower-Mate

PrecisionTemp Shower-Mate Shower-Mate Instantaneous Gas Water Heater Installation and Operating Instructions The Shower-Mate is a power vented automatic instantaneous water heater designed to be installed in ventilated marine applications.

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information