ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique

Size: px
Start display at page:

Download "ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique"

Transcription

1 i ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique modular system 262

2 Refrigeration & Air- Conditioning Technology Complete Solutions Commissioning and Maintenance Evacuation and Charging 266 Refrigeration Circuit Control Digital Manifold 267 Analogue Manifold 268 Pressure Hose 269 Tool Set 269 Leak Testing & Locating Nitrogen Set 270 Leak Detection Device 271 Evacuation Vacuum Pumps Recovery & Filling Refrigerant Recovery Device Recycling Bottles, Refrigerant 276 Refrigerant Scale 277 Accessories Cleaning, Tools, Adaptors Instructions for the Use of Refrigerants 280 Conversion Table Pressure, Temperature 281 Do you want to know more about our products? Please scan the QR-Code! 263

3 Complete Solutions ROKLIMA MULTI 4F Fully automatic commissioning and maintenance of air-conditioning units and heat pumps The innovative unit enables safe and comfortable operation on refrigeration systems. With simple menu navigation, 4 functions (4F) are automatically controlled Pressure resistance up to 80 bar guarantees full use with heat pumps Everything you need within reach Simple menu guidance guarantees appropriate use Fully-automatic gives time for parallel work Safe transport g 2,5 m R4A R22 R134a R407C R404A TECHNICAL DATA Weight: 17 kg Final Vacuum: 1 x -2 mbar Scale range: up to 0 kg Resolution: g Pressure hose length: 2,500 mm Pump rating: 42 l / min 4F Evacuation Charging Leakage test Control of the recovery process MAXIMAL SAFETY OF REFRIGERANT NO RISKS FOR THE ENVIRONMENT Interactive 16-digit display with 4 function buttons All required parameters can be easily entered Sturdy, compact metal casing Protects all components such as vacuum pump and scale 3 different pressure gauges Pulse-free, class 1.6, 80 mm Universal use on air-conditioning units with all common refrigerants and operation in the high pressure range with R4A Integrated high vacuum pump with 42 l/min suction performance For evacuation of the system in accordance with DIN pressure hoses (2,500 mm) from the series Plus with ball valve Safe and comfortable operation with refrigerants without the risk of refrigerant loss Plastic capillary hose Pull-out precision digital scale up to 0 kg Safe, leak-free filling due to shut-off valve Secure stand for large and small containers Shock-resistant low pressure and high pressure gauges for various refrigerants Secure storage of all accessories Pressure hoses: 2.5 m long with shut-off valve Bottle adaptor / 05 for scale and 1/4 reducing pieces 264

4 Complete Solutions Automatic evacuation and filling with the ROKLIMA MULTI 4F! Automatic supervision and control of the recovery process in refrigeration cycles! ROKLIMA MULTI 4F in use (evacuation and charging) Scope of delivery ( ) includes: 2-stage vacuum pump, 2 low pressure gauges, 1 high pressure gauge R4A, 2 pressure hoses with ball valve à 2,500 mm, 2 bottle connection adaptors (1/4 SAE , 5/16 SAE ), 2 reducing pieces 1/4 SAE - 5/16 SAE ( ), precision digital scale up to 0 kg, automatic control, vacuum and pressure switch, mineral oil ( ) ROKLIMA MULTI 4F Reducer pieces 1/4 SAE F - 5/16 SAE M kg Secure storage of Accessories: pressure hoses bottle adaptor, plastic capillary hose Precision scale up to 0 kg Resolution: g Accuracy ± 1% Ergonomic, Compact Light 265

5 Complete Solutions ROCADDY 120 / ROCADDY 120 Digital Universal sets for evacuation and charging 1,5 m Everything you need within reach Flexible use with the individual use of the tools Easy to transport Sturdy plastic rolling case (Fig. similar) Simple and comfortable transport with ample room for accessories and small parts TECHNICAL DATA Electric digital scale ROSCALE 120 with a weight capacity of 120 kg and a measuring accuracy per measurement of 5 g 2-stage vacuum pump ROAIRVAC 1.5 with integrated vacuum meter and solenoid valve, as well as a pump rating of 42 l/min Digital manifold (with ROCADDY 120 Digital) for the automatic calculation of superheat and subcool. 77 refrigerants are on file in the unit 2 analogue 4-way manifolds (with ROCADDY 120) for the common refrigerants R22, R134a, R404A, R407C and the high-pressure refrigerant R4A Pressure hose sets, each with 3 hoses from the PLUS series with shut-off valve for safe use with refrigerants Pipe cutter TUBE CUTTER 35 and MINICUT II PRO for cutting Ø 6-35 mm pipes to length Bottle adaptor for 1 kg and 2 kg refrigerant bottles for connection to the scale Secure mounting of the bottle during charging 2-stage high vacuum pump 2 x analogue manifolds (with ROCADDY 120) For evacuation and removal of all moisture residue in refrigeration systems during installation per DIN 8975 ROCOOL 600 Electronic digital scale up to 120 kg with high measurement precision Mini tube cutter and pipe cutter Automatic calculation of superheat and subcool. Optionally upgradable through attachment of a vacuum probe and a reading out function (with ROCADDY 120 Digital) Precise weighing of refrigerants For cutting Ø 6-35 mm pipes to length ROCADDY 120 includes: 2-stage vacuum pump ROAIRVAC 1.5 ( ) with vacuum gauge and solenoid valve, 4-way manifold for R22, R134a, R407C ( ), 4-way manifold for R4A ( ), pressure hose set 5/16 SAE each mm with ball valve for R4A ( ), pressure hose set 1/4 SAE each mm with ball valve for R22, R134a, R407C ( ), ROSCALE 120 ( ), 1x adaptor 3/8 SAE F ¼ SAE M ( ), 2x adaptor (5/16 SAE F ¼ SAE M with valve trigger ( ), adaptor 5/16 SAE M ¼ SAE F ( )), bottle connection ¼ ( ), bottle connection 5/16 ( ) mineral oil (0.4 l), Tube Cutter 35 ( 70027), Minicut II Pro ( 70402), transport case ( ) Performance kg ROCADDY 120 Digital includes: 2-stage vacuum pump ROAIRVAC 1.5 ( ) with vacuum gauge and solenoid valve, 1x digital manifold ROCOOL 600 ( ), 1x clamping thermometer ( ), pressure hose set 1/4 SAE mm with ball valve for R22, R134a, R407C ( ), ROSCALE 120 ( ), 1x 5/16 SAE F ¼ with valve trigger ( ), 1x 5/16 SAE M ¼ SAE F ( ), 1x bottle connection ¼ ( ), 1x bottle connection 5/16 ( ) mineral oil (0.4 l), Tube Cutter 35 ( 70027) Minicut II Pro ( 70402), transport case ( ) Performance kg R4A R22 R134a R407C R404A R4A R22 R134a R407C R404A R507 ROCADDY l / min with 2 analogue manifolds ROCADDY 120 Digital 42 l / min with digital manifold 266

6 ROCOOL 600 For commissioning, maintenance work and documentation of refrigeration systems of all kinds Refrigeration & Air-Conditioning Technology Refrigeration Circuit Control Modular system: The basic device can be fitted with the optional Red Box incl. the Data Viewer software for reading out or recording data on a PC. Additionally there is an optional external Pirani vacuum probe for precise vacuum readings More than 70 refrigerants incl. R744 (sub-critical) are stored in the device. New refrigerants can be added later using the update function Simultaneous calculation of superheat and subcool The documentation software Data Viewer generates an automatic report based on the data recorded. Ideal for handing out to the customer (client) An external Pirani vacuum probe allows reading of the vacuum where the most precise measurement is possible: directly at the refrigeration system Large screen TECHNICAL DATA Pressure display: bar, psi, Kpa, MPa Temperature display: C, F Vacuum display: Micron, mbar, mmhg, Pa, mtorr Power source: 9 V battery, 550 mah Screen size: 4.1/3 / 11 cm Pressure measurement range: -1 up to 60 bar Precision (at 22 C): ± 0,5 % fs Temperature measurement range: -50 C to +200 C Working temperature: - C to +50 C Connections: 4x ¼ SAE Max. recording time: 12h (device), 96h (red box) An absolute all-rounder due to the unique modular system! All important data at a single glance. Strong backlight for dark environment Connection for the temperature sensor T1 For automatic measurement of superheat data Connection for the external vacuum probe For very precise measurement of the vacuum level directly at the refrigeration system Connection for the temperature sensor T2 For automatic measurement of subcool data Green and red LEDs An optical signal is displayed once an adequate vacuum level is reached or leakage in the system and also a warning of overpressure Pressure sensors Made in Germany Precise measurement from -1 to 60 bar T-connection with Schrader valve ¼ SAE 3-way function: Evacuation and filling without changing a hose Temperature sensor for a pipe diameter of up to Ø 32 mm Connection of the Red Box To record data for up to 96 hours and independent read out of data at a PC External vacuum probe for very precise measurement of the vacuum Y-connections ¼ SAE A connection and sealing plug in one. Simple transport of hoses when not in operation Set ( ) includes: ROCOOL 600, 1 temperature sensor Set ( ) includes: ROCOOL 600, 2 temperature sensors, carry case Set ( ) includes: ROCOOL 600, 2 temperature sensors, red box and data viewer software, carry case Scope of delivery ( ): Red box, data viewer software, connection cable, external power supply Set with 1 temperature sensor (in the blister) Set with 2 temperature sensors (in the case) Set with 2 temperature sensors, red box, data viewer software (in the case) Red box, software, connection cable, external power supply Temperature sensor Vac Probe

7 Refrigeration Circuit Control Analogue Manifolds 2- and 4-way manifolds Pressure gauge with shock-proof rubber protector Pressure gauge Ø 80 mm, with pulse-dampening class 1.6 Protects against damage Easy-to-read, high precision display Valve body made of aluminium with gauge glass Large hand valve with colour coding Light, secure and precise opening and closing of the diaphragm valve, maintenance free Valve sets Sturdy despite low weight 2-way manifold Manifold Blister ND*/bar HD*/bar kg R22 R134a R407C 2-way, 1/4 SAE -1 up to 17 0 up to way, 1/4 SAE -1 up to 17 0 up to R4A R404A 2-way, 5/16 SAE -1 up to 30 0 up to way, 5/16 SAE -1 up to 30 0 up to *LP = Low pressure manifold, *HP = High pressure manifold Blue rubber protector for manifold Red rubber protector for manifold Valve sets for manifold Manifold Sets Manifold sets and pressure hoses 1,5 m 2-way manifold (for and ) 4-way manifold (for , , and ) Durable and highly precise tool Sets include: Manifold, pressure gauge with Ø 80 mm, Pulse-free, class 1.6, 3 x 1,500 mm pressure hoses, plastic carrying case kg 2-way Standard Pressure hose with ball valve Plus (only for and ) No loss of refrigerant R22 R134a R407C R404A Manifold set 2-way Standard R4A Manifold set 2-way Standard way Standard R22 R134a R407C R404A Manifold set 4-way I Standard R4A Manifold set 4-way I Standard way Plus R22 R134a R407C R404A Manifold set 4-way II Plus R4A Manifold set 4-way II Plus Plastic carry case

8 3-piece Pressure Hose Sets Refrigeration & Air-Conditioning Technology Refrigeration Circuit Control Available in Standard and Plus 1,5 m Safety Standard for SAE No confusion and safe use with the colour coding (blue, red, yellow) Teflon seal with up to x longer service life compared to neoprene seal Working pressure 60 bar / burst pressure 300 bar. This is an 8 % better pressure resistance as previously R4A R22 R134a R407C R404A Standard series Plus series Pressure hose from the series Standard Pressure hose from the series Plus with ball valve Connection L mm Vacuum Hose 3/8 SAE 1, R22 R134a R407C R404A Set of 3 pressure hoses 1/4 SAE 1, Pressure hose yellow 1/4 SAE 1, R4A Set of 3 pressure hoses 5/16 SAE 1, Pressure hose yellow 5/16 SAE 1, Connection L mm R22 R134a R407C R404A Set of 3 pressure hoses 1/4 SAE 1, Pressure hose yellow 1/4 SAE 1, R4A Set of 3 pressure hoses 5/16 SAE 1, Pressure hose yellow 5/16 SAE 1, Tool Set Climate I + II Practical tool set with all tools required For installation and maintenance of air-conditioning units and heat pumps APPLICATION AREA Monitor temperature and pressure Quality hoses with high bursting pressure Pipe cutter for all pipe cross-sections from 3-35 mm (1/8-1.1/8 ) Measurement of ambient and ventilator air temperature Clean, kink-free bending of all common pipe cross-sections Optimum flaring connections for all types of air-conditioners R22 R134a R407C R404A The ideal introduction into a whole new area of business! Set Climate I ( ) includes: 2-way manifold ( ), set of pressure hoses standard 1/4 SAE, Tube Cutter 35 C ( C), minicut pipe cutter (070401C), thermometer, set of bending springs 3/8-1/2-5/8, universal flaring tool ( ), plastic case Set Climate II ( ) includes: 2-way manifold ( ), set of pressure hoses standard 5/16 SAE, Tube Cutter 35 C ( C), minicut pipe cutter (070401C), thermometer, set of bending springs 3/8-1/2-5/8, Reeling Flaring Tool ( ), plastic case kg Tool Set Climate I Tool set Climate II

9 Leak Testing & Locating Nitrogen Set Multiple uses for refrigeration systems CE Safety Standard for TPED APPLICATION AREA Pressure and leak test with nitrogen Flushing of the installation Nitrogen admission during soldering to prevent scale formation Ideal for split air-conditioning units and heat pumps! 950 cm 3 nitrogen bottle included Complete set Connection for large bottles Any size of bottle can be connected without a problem Spring loaded pressure reducing valve Simple and safe handling Fine scaled 1.0 pressure gauge Precise reading of the testing pressure /16 SAE adaptor for connecting to R4 units Bottle adaptor for connecting 950 cm 3 bottles Set ( ) includes: pressure reducing valve, connection hose, bottle adaptor, pressure gauge, nitrogen bottle and plastic case Nitrogen set with bottle (950 cm 3 ) Nitrogen bottle, each 950 cm Filling hose with pressure gauge 2590 Connection 5/16 SAE internal, 1/4 SAE external

10 Leak Testing & Locating RO-LEAK Electronic leak detection device for locating leaks in refrigeration systems (3 g/a) Durable and highly sensitive sensor tip with a leak detection rate of 3 g/a within 3 seconds Simple determination of the refrigerant concentration Adjustment of the sensor tips zero measurement point for simple detection of the leak Exact and quick locating of the leak Easy accessibility of even hard to reach leaks R4A R22 R134a R407C R404A R507A TECHNICAL DATA Leak status: LED display Sensor length: 30 cm Leak detection rate: 3 g/a within 3 seconds Weight: 280 g Working temperature: - up to + 49 C Voltage: 2.4 V Heated pentode Durable and highly sensitive sensor tip with a leak detection rate of 3 g/a within 3 seconds Audio signal Comfortable use 30 cm long, flexible sensor Easy access in hard-to-reach places 7 LEDs Simple determination of the refrigerant concentrate with the coloured shading 7 different sensitivity levels Exact and fast location of the leak RESET - button Adjusts to the sensor tip zero point setting for simple leak location Suitable for all common CFC, HFC and HCFC! RO-LEAK in use Scope of delivery ( 87305) Leak detection unit RO-LEAK, spare sensor, battery charger, battery RO-LEAK set with spare sensor and battery charger in plastic case Spare sensor

11 Evacuation ROAIRVAC Two-stage vacuum pump For evacuation in accordance with DIN 8975 with vacuum gauge and solenoid valve Solenoid check valve to protect the refrigeration system from oil contamination during power outage Vacuum gauge with integrated drag indicator enables simple and quick control of the evacuation process Protects the integrated components with the light and high quality casing Gas ballast valve for reduction of water vapour in the oil container Special filter reduces oil mist on exhaust vent Gauge-glass enables easy oil-stand monitoring Fast filling of oil without spilling, no special funnel is necessary Easy access to the oil drain plug makes emptying quick Thermal switch protects the unit from the motor overheating Standard 1/4 SAE connection, as well as 5/16 SAE and 3/8 SAE adaptor included in delivery Removable cable prevents cable damage Ergonomic handle Light, compact and easy to transport Gas ballast valve Reduction of water vapour in the oil container, guarantees higher evacuation performance and service life Removable cable Prevents cable damage Special filter Reduces oil mist on exhaust vent Integrated vacuum gauge Simple and fast control of the evacuation process Integrated solenoid valve Light and high-quality casing Protects the integrated components Four-pole motor* Increased torque and long service life *(only with ROAIRVAC 1.5 and 3.0) Prevents backwash of oil into the refrigeration system 1/4 SAE standard connection with adaptors for 5/16 SAE and 3/8 SAE Optimal positioned viewing glass and oil drains for simple draining of the oil Practical: operating instructions always within view 272

12 ROAIRVAC Serie Two-stage rotary vane pump for evacuation in accordance with DIN 8975 Refrigeration & Air-Conditioning Technology Evacuation Type ROAIRVAC 1.5 ROAIRVAC 3.0 ROAIRVAC 6.0 ROAIRVAC Pumprating 1.5 CFM / 42 l/min / 2.5 m 3 /h 3.0 CFM / 85 l/min / 5.1 m 3 /h 6.0 CFM / 170 l /min /.2 m 3 /h 9.0 CFM / 255 l/min / 15.3 m 3 /h Vacuum stages Final-vacuum 25 micron / mbar 25 micron / mbar 25 micron / mbar 25 micron / mbar Motor rating 190 W / 1720 r/m 250 W / 1720 r/m 375 W / 3440 r/m 750 W / 3440 r/m Voltage 230 V 230 V 230 V 230 V Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz Connections 1/4 1/4 1/4 1/4 with adaptor 5/16 SAE M / 3/8 SAE M 5/16 SAE M / 3/8 SAE M 5/16 SAE M / 3/8 SAE M 5/16 SAE M / 3/8 SAE M Oil capacity 250 ml 330 ml 330 ml 590 ml Weight 9.0 kg.7 kg 11.5 kg 17.0 kg Pressure gauge Ø 50 mm 50 mm 50 mm 80 mm Measuring unit mbar / Mpa mbar / Mpa mbar / Mpa mbar ROAIRVAC 1.5 (42l/min) ROAIRVAC 3.0 (85l/min) ROAIRVAC 6.0 (170l/min) Mineral oil is included in all pump deliveries ROAIRVAC 9.0 (255 l/min) ROAIRVAC - vacuum pump in use with the digital manifold ROCOOL 600 Scope of delivery ROAIRVAC: Vacuum pump with 1/4, 5/16 SAE and 3/8 SAE connections, plastic bottle with mineral oil Performance kg ROAIRVAC l/min ROAIRVAC l/min ROAIRVAC l/min ROAIRVAC l/min Mineral oil, 1 litre

13 Recovery & Filling ROREC Refrigerant recovery device Compact, portable device for recovery and recycling refrigerants of all kinds 4-pole motor guarantees the durability of the machine Low noise and vibration emission thanks to the compact design Intuitive handling makes it simple and safe to use Maintenance-free operation through the oil-free compressor Emptying of the device in order to work with different refrigerants with the PURGE function Simple transport and use with the light and compact plastic casing Ideal for mono & multi-split airconditioning units and heat pumps! TECHNICAL DATA Suitable for: all refrigerants of the type CFC-HCFC-HFC Capacity: gaseous: 0.26 kg / min fluid: 1.85 kg / min Push/Pull: 6.22 kg / min Electrical Data: 230 V / 50-60Hz Power: 370 W High pressure switch: 38.5 bar Dimensions: 490 x 244 x 353 mm Weight: 17 kg Oil-free compressor Maintenance-free operation Integrated high pressure switch Protects the integrated components PURGE function Emptying of refrigerant residue in the unit (self-cleaning mode) Thermal switch Protects the unit from overheating Simple use Controlled dosage of the refrigerant supply Light and compact plastic casing Simple transport and use RESET Button Reset of the pressure shut-off Removable cable Prevents cable damage 4-pole motor Increased torque and service life Recovery of Refrigerant Exemplary: Outdoor air-conditioning unit Low Simple and precise reading with the glycol filled pressure gauge Practical storage compartment for accessories on the back High Low High Filter ROREC Connected Load kg ROREC 370 W Filter

14 Recovery & Filling ROREC PRO Refrigerant recovery device Compact, portable device for recovery of halogenated refrigerants of every kind Maintenance free operation with the oil-free 2-piston compressor 4-pole motor guarantees the durability of the machine Automatic shut-off after the evacuation process is finished Low-noise and vibration emission thanks to the compact design Intuitive handling makes it simple and safe to use Emptying of the device in order to work with different refrigerants with the PURGE function Simple transport and use with the light and compact plastic casing TECHNICAL DATA Suitable for: all refrigerants type CFC-HCFC-HFC Capacity: gaseous: 0.52 kg / min fluid: 3.70 kg / min Push/Pull: 9.95 kg / min Electrical Data: 230 V / 50-60Hz Power: 730 W High pressure switch: 38.5 bar Dimensions: 490 x 244 x 353 mm Weight: 19 kg Oil-free 2-piston compressor Also ideal for large facilities! Very high suction performance with maintenance free operation Control lamp When green: Process is over - unit will turn off automatically When red: The system pressure is too high - unit will turn off automatically Thermal switch Protects the unit from overheating Simple use Controlled dosage of the refrigerant supply Light and compact plastic casing Simple transport and use PURGE function Emptying of refrigerant residue in the unit (self-cleaning mode) Removable cable Prevents cable damage 4-pole motor Increased torque and service life Simple and precise reading with the glycol filled pressure gauge Practical storage compartment for accessories on the back ROREC PRO in use Connected Load kg ROREC PRO 730 W Filter

15 Recovery & Filling Refrigerant Recycling Bottles Empty, welded press gas bottles for collection of used refrigerant, volume: 14.5 litre, maximum filled weight: kg, double connection valve for gaseous and fluid removal with dip pipe for standing bottle. With 2-way fill / disposal valve, bottle label and complete ADR papers. Colour is without obligation. Collection and disposal only possible in Germany 2-way fill/disposal valve Liquid and gaseous removal possible Bottle includes complete refrigerant recycling No rent, no separate disposal costs (only in Germany) Clear labelling on the bottle ( max kg ) Prevents overfilling, no danger of explosion due to increase of temperature Ø mm Height mm Recycling bottle 1/4 SAE including complete refrigerant recycling Refrigerant for Air-conditioning Units Non-chlorinated refrigerant of the HFC group in practical 40 bar steel bottles (bursting pressure: 165 bar) TÜV seal /03D and TPED accepted as per 99/36/CE F-GAS EU 842/ 2006 REGULATION CE Safety Standard for TPED Refillable bottles Standardised SAE thread on all bottle valves Universal application Light and practical for use on building-sites 1 and 2 litre steel bottles, rent-free and easy disposal Flat base for increased standing stability Ease of clean up after removing of the valve Full flexibility for the user R407C Refrigerant R407C in cardboard packaging 1 l steel bottle 1/4 SAE l steel bottle 1/4 SAE R4A Refrigerant R4A in cardboard packaging 1 l steel bottle 5/16 SAE l steel bottle 5/16 SAE

16 Recovery & Filling ROSCALE 120 Electronic refrigerant scale Precise, easy to handle refrigerant scale for filling and evacuation processes with a maximal weight capacity of 120 kg Resolution of 5 g enables very precise filling Weight capacity sufficient for all common refrigerant bottles Cable connection enables comfortable use in every situation Bottle adaptor for connecting small refrigerant bottles (1 l and 2 l bottles) Refrigerant bottles of all sizes have enough space Large LCD display for comfortable reading of the result Simple use TECHNICAL DATA Weight capacity: 120 kg or 264 lbs Accuracy: +/- 0,5% Resolution: 5 g / 0,2 oz. Working temperature: - C up to +49 C / 14 up to +120º F Connection: 1/4 SAE for 1-2 lit. bottles Battery: 9 V Platform size: 230 x 230 x 53 mm Weight: 3.28 kg 1/4 SAE bottle adaptor For connecting small 1 and 2 l refrigerant bottles Large rubberised weighing platform All sizes of refrigerant bottles have enough space Large LCD display For comfortable reading of the results Three operating keys Simple use Cable connection Enables comfortable use in every situation Weight capacity of 120 kg Weight capacity is sufficient for all common refrigerant bottles Scope of delivery: ROSCALE 120, 9 V battery, carrying case kg ROSCALE ROSCALE 120 in carrying case 277

17 Accessories SANIFRESH Disinfecting and deodorising cleaning spray Removes the threat of disease and allergies Practical and ecologically friendly solution for removing mites, dust, bacteria and spores Spray is applied directly to affected surface Economical spray can with spray nozzle and spray tube Removes unpleasant odours. Pleasant mint smell Volume Sanifresh (contains 12 bottles) 1 1(12) 400 ml Bottle Connection and Adaptors For refrigerant bottles For use with new refrigerant bottles on existing equipment , Adaptor, 1/4 connection Adaptor, 5/16 connection Adaptor, W21.8 x 1/4 SAE M connection with seal for 2 l sized bottles Adaptor, 1/4 SAE M - 3/8 SAE F connection Adaptor, 3/8 SAE M - 1/4 SAE F connection Adaptor, 1/4 SAE F - 5/16 SAE M connection Adaptor, 1/4 SAE M - 5/16 SAE F connection with valve trigger Torque Wrench Set For proper tightening of flange connections Set with adjustable torque wrench (-70 Nm) and 6 spanner inserts sizes 17, 22, 24, 26, 27 and 29 mm for flange connections on 1/4, 3/8, 1/2 and 5/8 pipe lines according to DIN EN : Fix with torque urgently necessary! 8 piece set ( ) includes: spanner wrench sizes 17, 22, 24, 26, 27, 29 mm, torque wrench, carrying bag Pipe-Ø Spanner width Locking torque 1/4 / 6 mm 17 mm Nm 3/8 / mm 22 mm Nm 1/2 / 12 mm 24 mm Nm 1/2 / 12 mm 26 mm Nm 5/8 / 15/16 mm 27 mm Nm 5/8 / 15/16 mm 29 mm Nm kg Torque wrench set, 7 piece

18 Adjustable Wrench Chrome vanadium steel, drop forged, chrome-plated and polished Precise operation: Smooth-running and robust roller with minimum play in the sliding guides Refrigeration & Air-Conditioning Technology Accessories Size Clamping width inch mm up to mm g , Schrader Valve Tool For exchanging the Schrader valve on air-conditioners under pressure, without having to recover the unit For safe and easy change of spring insert of the Schrader Valve Tool With safety thread for risk-free use with R4A Schrader Valve Tool in plastic carrying case Plate Fin Comb For straightening the plate fins of heat-exchangers 6 different sizes in one tool Dimension Plate fin comb mm

19 General instructions for the use of Refrigerants Refrigerant data from CFC-alternative refrigerants Refrigerant Composition ODP GWP Temperature glide R22 (HFC-CFC refrigerant) CHCLF ,700 R134a (HFC chlorine-free refrigerant) CF3CH2F 0 1,300 R32 (HFC chlorine-free refrigerant) CH2F R404A (HFC chlorine-free blends) 52% R143a, 44% R125, 4% R134a 0 3,750 R507 (HFC chlorine-free blends) 50% R143a, 50% R ,800 R407C (HFC chlorine-free blends) 23% R32, 25% R125, 52% R134a 0 1,6 7.5K R4A (HFC chlorine-free blends) 50% R32, 50% R , K ODP = Ozone Depletion Potential (degree in which the ozone layer is destroyed) GWP = Global Warming Potential (degree in which it contributes to the greenhouse effect) Instructions for safe and proper use of the refrigerants: Refrigerant: Wear protective gloves and safety goggles Do not let refrigerant come in contact with skin Do not inhale high concentrations of vapours (Lack of oxygen causes a narcotic effect and is a danger to life) Do not smoke around refrigerant Working place / room must be thoroughly aired, if necessary extracted Refrigerant bottles: Secure against accidents, do not throw Do not expose to direct sunlight and do not place near radiators or other heat sources Do not use open flame Do not disassemble or remove valves Damaged bottles need to be properly returned Close empty containers Air-conditioners: Air-conditioner leaks need to be repaired immediately Do not allow refrigerant to leak while filling or doing maintenance work In high concentrations (for example pipe burst), leave the room and do not enter again until it has been properly ventilated Only do brazing work together with protective nitrogen gas and only in well ventilated areas Flare connections Normal flare size in accordance with JIS B8607:2008 Flare outer diameter in relationship to the pipe diameter Pipe outer diameter mm / inch Metric Wall thickness mm / inch Flare outer diameter with R22-, R134a-, R404-, R407C air-conditioners Flare outer diameter with R4A air-conditioners 6 mm 1 mm 8.5 mm 9.1 mm 8 mm 1 mm 11.1 mm 11.1 mm mm 1 mm 13.6 mm 13.2 mm 12 mm 1 mm 15.3 mm 16.5 mm 16 mm 1 mm 19.5 mm 19.2 mm 18 mm 1 mm 22.0 mm 22.7 mm 1/ mm mm 9.1 mm 5/ mm mm 11.1 mm 3/ mm mm 13.2 mm 1/ mm mm 16.6 mm 5/ mm mm 19.7 mm 3/ mm mm 24.0 mm 280

20 Conversion table pressure Refrigeration & Air-Conditioning Technology Conversion Table Pressure, Temperature mbar Micron TORR mm HG Vacuum 7, , , Conversion table temperature Conversion from C in F: C x = F Conversion from F in C: ( F-32) : 1.8 = C C F C F F C F C Common threads UNF-Thread SAE-Thread Outer diameter Internal diameter Lodes per inch Increment (max. mm) (min mm) (mm) 7/ / /2-20 5/ /8-18 3/ /4-16 1/ / /8-14 5/ / / / /4-12 7/ / /

O NEof Premium tools for professionals!

O NEof Premium tools for professionals! O NEof 6.000 Premium tools for professionals! 284 Refrigeration & Air Conditioning Technology System Overview 286-287 Complete Solutions Comissioning & Maintenance 288-290 Evacuation & Charging 290 Refrigeration

More information

Refrigeration and AirConditioning Equipment

Refrigeration and AirConditioning Equipment 320 Refrigeration and AirConditioning Equipment System Overview Refrigeration and Air-Conditioning Equipment Fully Automatic Vacuum and Charging Stations Recovery and Recycling Units High Vacuum Pumps

More information

INFRARED THERMOMETER. Thermometer

INFRARED THERMOMETER. Thermometer INFRARED THERMOMETER Usefull infrared thermometer for temperature measurements between -20 C und 420 C. A laserbeam makes it easier to meassure the temperature of the object. A big LC screen displays the

More information

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology. Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. 01_Brochure_testo552_MASTER.indd 1 30.01.2013 11:27:13 Testo refrigeration technology

More information

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology. New: now with App and Bluetooth. Measurement Solutions for Refrigeration Technology. Complete solution for the commissioning and maintenance of refrigeration systems and heat pumps. testo 549, testo 550,

More information

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold LOW VAC INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold REF HIGH SPECIAL FEATURES Low battery indicator Displays 63 refrigerants Displays corresponding saturation, dew or bubble point temperature

More information

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual

More information

Repair instruction and handling for Isobutane (R600a) refrigerant.

Repair instruction and handling for Isobutane (R600a) refrigerant. Repair instruction and handling for Isobutane (R600a) refrigerant. Refrigerant Isobutane R600a Isobutane is a colourless gas with a slight odour. It is also known as cigarette lighter fuel and camping

More information

REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES

REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES / ACCESSORIES High performance Lightest vacuum pump VACUUM PUMP.8CFM Eco Applicable to room air-conditioner, package air conditioner up to 5HP.8CFM Eco Code No.WV0 Suitable for vacuuming small 5HP refrigeration.

More information

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning

More information

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf Driven by CLIMATISATION Excellence for professionals Bosch air conditioning service units for R-134a and R-1234yf A/C service from Bosch Air conditioning systems in vehicles require regular maintenance.

More information

PATENTED PATENT PENDING PATENTED PATENTED

PATENTED PATENT PENDING PATENTED PATENTED 2 3 Our services Saniflux Hybrid Diag Nitro Hermetic PATENTED PATENT PENDING PATENTED PATENTED The first A/C system and passenger compartment air purification system combined with a charging station. 2

More information

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Some of these procedures need to be performed to conform to requirements of the Clean Air Act. Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.

More information

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery. HET- 190 ESL Support page 1 CORE Basic Refrigeration Circuit 1. Liquid refrigerant boils in the evaporator. Heat is absorbed. The heat energy absorbed converts refrigerant liquid into vapor. 2. Refrigerant

More information

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc. 1 High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A Hitachi Appliances, Inc. 2 Introduction The situation faced by the refrigeration / air conditioning industry

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TR600 Series Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TR600, TR610, TR600C, TR610C, TR600S, TR600K, TR600E TO BE

More information

Refrigerant Recovery Unit, Model RRU134

Refrigerant Recovery Unit, Model RRU134 Installation, Operation & Maintenance Manual IOMM RRU134 Group: Refrigerant Effective: December 2000 Supersedes: New Refrigerant Recovery Unit, Model RRU134 1999 McQuay International Table of Contents

More information

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge ENSPECO Recovery/ Recycle/ Evacuate/ Recharge RMS 3012 RMS 3034 Approved by UL/SAE to J-1991 R12 Purity Standards Approved by UL/SAE to J-2210 R134 Purity Standards This semi-automatic machine will recover

More information

Caresaver Universal Refrigerant Recovery Unit

Caresaver Universal Refrigerant Recovery Unit Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2

More information

Digital, not analog: One manifold for all refrigeration systems.

Digital, not analog: One manifold for all refrigeration systems. Digital, not analog: One manifold for all refrigeration systems. Our refrigeration measurement technology intuitive, efficient, reliable: Welcome to the Smart World of Testo. www.testo.com Why wait? Digital

More information

Vacuum in the laboratory. products and solutions

Vacuum in the laboratory. products and solutions Vacuum in the laboratory products and solutions Vacuum filtration is frequently used for sample preparation in microbiology, waste water control and analysis. With a final vacuum of 100 mbar, 90% of atmospheric

More information

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds.

Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds. Perfect for testing. Perfect for service. The testo Smart Probes Air Conditioning set. The testo 550/557 digital manifolds. Discover the smart world of air conditioning system maintenance. The testo Smart

More information

Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds

Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds Matériels et outillages Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds Flexibles et raccords Outillages

More information

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES DEVICES AND ACCESSORIES PROMAX RECOVERY DEVICES PROMAX designs, engineers, and manufacturers the highest quality service equipment and makes it easy to use for all refrigerant handling

More information

AIR CONDITIONNING 95 CODE 002

AIR CONDITIONNING 95 CODE 002 CODE 002 AIR CONDITIONNING 95 Cool-Tech Refrigerant Recovery/Recycling Unit Model 34788 It recovers, recycles, evacuates, leak tests, and recharges R-134a quickly and accurately. Fully automatic function

More information

Equipment. Application of refrigerants and heat transfer fluids Application of brazing alloys Application of insulation EQUIPMENT

Equipment. Application of refrigerants and heat transfer fluids Application of brazing alloys Application of insulation EQUIPMENT Matériels et outillages Mise en œuvre des fluides frigorigènes Matériels de transfert et de récupération Balances Appareils de mesure et de contrôle Pompes à vide Manifolds Flexibles et raccords Outillages

More information

1. General Description

1. General Description 1. General Description A: SPECIFICATIONS 1. HEATER SYSTEM Heating capacity 2. A/C SYSTEM AUTO A/C MODEL Item Specifications Condition 5.0 kw (4,300 kcal/h, 17,062 BTU/h) or more AC-2 Mode selector switch:

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV20 LARGE CAPACITY REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01101 LV20.DOC NRP-OM-LV20

More information

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved. GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant

More information

BAC 4000a BAC 5000yf

BAC 4000a BAC 5000yf AC Service Units BAC 4000a BAC 5000yf AC Service Units Recommended by Volvo Cars Fully-automatic, high capacity and comfortable Maximum safety Easy to use BAC 4000a Maximum precision easy operation. The

More information

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Prüftechnik ACS 600, 601, 650 Air conditioning service units from Bosch NEW! Ñ ACS 600 even the entry model is fully

More information

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System Certified by ITS to meet SAE J2810 for R-134a Designed to meet new SAE J2851 for R-1234yf MANUAL GENERAL INFORMATION Table of

More information

PATENTED PATENT PENDING PATENTED PATENTED

PATENTED PATENT PENDING PATENTED PATENTED 2 3 Our services Saniflux Hybrid Diag Nitro Hermetic PATENT PENDING The first A/C system and passenger compartment air purification system combined with a charging station. 2 services in a single station!

More information

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651 Bosch: bringing you the workshop of the future For over 125 years, Bosch innovations have been keeping vehicles on the road and getting people to and from their destinations while improving safety and

More information

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE Fluid Exchange Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories 423 ASCOT 424 Refrigerant Recovery/Recycling Systems Recovery and Recycling Systems

More information

AC1234 PRODUCT RANGE.

AC1234 PRODUCT RANGE. AC1234 PRODUCT RANGE THE REFERENCE POINT FOR THE MAINTENANCE OF THE R-1234YF A/C SYSTEMS www.ac1234yf.com AC1234-8, AC1234-7 AND AC1X34-7 AC1234-8 and AC1234-7 are service stations which perform maintenance

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL LV8 COMMERCIAL REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 A01001 7/11/96 NRP-OM-LV8 7/96

More information

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4. 1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4. INSTALLATION OF THE INDOOR UNIT 5. CONDENSATE HOSE CONNECTION

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge.

Manifold Gauge LD.R1.02 LD.R1.01. manifold gauge. manifold gauge. brass body. brass body LD.R1.04 LD.R1.03. manifold gauge. Manifold Gauge LD.R1.01 manifold gauge brass body LD.R1.02 manifold gauge brass body LD.R1.03 manifold gauge aluminum body LD.R1.04 manifold gauge aluminum body LD.R1.05 manifold gauge aluminum body LD.R1.06

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CDITIERS TECHNICAL & SERVICE MANUAL No. OCH468 REVISED EDITI-A HFC utilized R4A June 2 [Model name] MXZ-8B48NA PAC-AKA5BC PAC-AKA3BC (Indispensable

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration Calhoon MEBA Engineering School Study Guide for Proficiency Testing Refrigeration 1. To prevent an injury when working with refrigerants, what safety precautions are necessary? 2. When halogens are in

More information

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE

More information

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual Model: Ariazone 601 HD Serial No: 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before operating

More information

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM Guangzhou Junliye Import&Export Co., Ltd. AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL 1. Cautions: Wear the glove and eye protection glass to protect the skin and eyes from

More information

TEMPERATURE SHOCK TEST CHAMBERS

TEMPERATURE SHOCK TEST CHAMBERS E SHOCK TEST CHAMBERS TEST STANDARDS VARIOUS TEST POSSIBILITIES Thanks to rapid and high-speed temperature change tests, failures on products which will undergo such extreme impacts can be detected in

More information

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING How to deal with R32 R125 R410A...R410A MITSUBISHI ELECTRIC AIRCONDITIO NING R410A Contents What is R410A?......................................... 3 Expressions...........................................

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which

More information

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4

More information

HS25 SERVICE UNIT INFORMATION

HS25 SERVICE UNIT INFORMATION SERVICE UNIT INFORMATION HS25 Corp. 9327-L3 Litho U.S.A. HS25 SERIES UNITS The HS25 is a high efficiency residential split system condensing unit which features a scroll compressor. It operates much like

More information

Technical data sheet. Lyovapor L-300

Technical data sheet. Lyovapor L-300 Lyovapor L-300 Technical data sheet With Infinite-Technology the Lyovapor L-300 offers continuous sublimation for the first time with two alternate working and automatically hygienically cleaned condensers

More information

Residential Piping and Long Line Guideline

Residential Piping and Long Line Guideline AC / HP R-410A Refrigerant Systems Single-Stage, Two-Stage and Variable Speed Models Residential Piping and Long Line Guideline TABLE OF CONTENTS Safety Considerations... 2 Definitions... 2 Introduction...

More information

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC. Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER

More information

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700 A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,

More information

An ISO 9001 : 2008 Certified Company

An ISO 9001 : 2008 Certified Company NITROGEN TYRE AIR INFLATOR Model - FS 3500 TECHNICAL DETAILS Nitrogen purity Compressed air input range Nitrogen output N2 output pressure Nitrogen storage tank Motor power Motor voltage Weight Packing

More information

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning This initiative was developed by: Content and guidance kindly provided by the following organisations: Cool Drive CPS Asia Pacific

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed. 1 TECHNICAL CHANGES MUZ09UN MUZ-A09NA MUZ12UN MUZ-A12NA MUH15TN MUZ-A15NA MUH17TN MUZ-A17NA MUH24WN MUZ-A24NA MU15TN MUY-A15NA MU17TN MUY-A17NA MU24WN MUY-A24NA 1. Outdoor unit model has been changed.

More information

SERVICE BULLETIN A

SERVICE BULLETIN A 1. PLANNING INFORMATION A. Effectivity: Dassault Falcon 10 aircraft which have installed R-134a Upgrade Kit SZ59K-R134 before August 8, 2002. B. Reason: Upgrade kits before August 8, 2002 did not include

More information

Advantages / Characteristics

Advantages / Characteristics Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg

More information

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground

More information

TRS21 IGNITION PROOF SERIES

TRS21 IGNITION PROOF SERIES TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Ariazone 601HD Refrigerant Recovery&Recycling unit

Ariazone 601HD Refrigerant Recovery&Recycling unit Automotive Air-Conditioning Service Equipment Ariazone 601HD Refrigerant Recovery&Recycling unit OPERATOR MANUAL 1 1. SAFETY FIRST! Important safety information's - Read this user manual carefully before

More information

REFRIGERANT SYSTEM SERVICE WARNINGS

REFRIGERANT SYSTEM SERVICE WARNINGS 2005 HVAC Refrigerant System - MX-5 Miata REFRIGERANT SYSTEM SERVICE WARNINGS USING/HANDLING UNAPPROVED REFRIGERANT Using a flammable refrigerant, such as OZ-12, in this vehicle is dangerous. In an accident,

More information

OPER LV Wheeler Way

OPER LV Wheeler Way OPER RATING INSTRUCTIONS LV5 REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 Ph:(215) 638-8909 9 info@ @nrproducts.com LV5.DOC 9.17.2018 MODEL LV5 REFRIGERANT

More information

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car A/C Refrigerant Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car Refrigerants are HAZARDOUS to you and the environment Motor Vehicle Air Conditioning

More information

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM OPERATION MANUAL Index I Caution.... 2 II Notation.. 2 III Technical parameter...3 IV Functions... 3 V Device Description. 3 (I) Control panel. 4

More information

Chemistry diaphragm pumps

Chemistry diaphragm pumps Oil-free vacuum for corrosive gases and vapors Chemistry diaphragm pumps Series overview Examples of use Down to 70 Pumping of aggressive gases and vapors For low-boiling solvents Vacuum filtration Down

More information

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 12 RM85 PACKAGE CONTENTS Item Description Quantity 10560RG-US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube

More information

Hydraulic Reservoir Made of Polymer (TMP) or Steel (TMS)

Hydraulic Reservoir Made of Polymer (TMP) or Steel (TMS) Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics Service Hydraulic Reservoir Made of Polymer (TMP) or Steel (TMS) RE 9571/0.11 1/1 Replaces: 0.09 Data sheet Hydraulic

More information

Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD

Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD Automotive Air-Conditioning Service Equipment Ariazone 5001HD OPERATOR MANUAL Ariazone 5001HD - Automotive A/C Service Station 1 Contents Page 1. Introduction... 3 2. Safety firts... 4 3. Technical Features...

More information

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS Digital Refrigerant System Analyzer INSTRUCTION MANUAL ENGLISH LOW START PRS T-LOW SUPERHEAT MAXMIN kpa Bar MPa R TIME P T HIGH END PRS T-HIGH SUBCOOL VAC 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com

More information

VACUUM HEATING AND DRYING OVENS Gentle and safe

VACUUM HEATING AND DRYING OVENS Gentle and safe VACUUM HEATING AND DRYING OVENS Gentle and safe Quality Products Lifetime Care VACUTHERM 6000 USER FRIENDLY AS NEVER BEFORE The intelligent, modular system: three sizes and two types of heating Series

More information

Refrigerant Recovery/Recharging Series

Refrigerant Recovery/Recharging Series TrustworthyBrandChinaChunMu Refrigerants TrustworthyBrandChinaChunMu 2012 Refrigerant /Recharging Series Portable Refrigerant /Recharging Unit Light Commercial HVAC Industrial Refrigeration System Automotive

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

Refrigeration and Air-conditioning Technology. Modular R134a refrigeration training system

Refrigeration and Air-conditioning Technology. Modular R134a refrigeration training system Refrigeration and Air-conditioning Technology Climate change, the greenhouse effect and global warming in the 21st Century there is scarcely any other subject that is more ubiquitous or hotly debated.

More information

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications: TECHNICAL DATA SHEET Features and uses of is a non-azeotropic blend of HFC with zero Ozone Depletion Potential et low Global Warming Potential (GWP), formulated to meet the requirements of the F-Gas Regulation

More information

OWNER S MANUAL (English)

OWNER S MANUAL (English) TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories Freeze Dry Systems AN OVERVIEW Table of Contents: Overview................................... 1 Selection Guide.............................. 4 FreeZone Freeze Dry Systems

More information

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing Do s & Don ts in Refrigeration & Air-Conditioning Servicing Who is Better? OR Common Practices that are damaging to the Refrigeration & Air-conditioning Systems Brazing with Cu electrode for brazing Cu

More information

HVACR Refrigeration

HVACR Refrigeration Western Technical College 10601101 HVACR Refrigeration Course Outcome Summary Course Information Description Career Cluster Instructional Level Total Credits 4.00 Total Hours 108.00 This course is an introduction

More information

Your competent partner for measuring and services.

Your competent partner for measuring and services. Your competent partner for measuring and services. Intuitive, efficient, reliable everything for facility management: Welcome to the Smart World of Testo. 1 Too cold, too draughty, too humid? With the

More information

HP13 WARNING WARNING. Service Literature HP13 SERIES UNITS

HP13 WARNING WARNING. Service Literature HP13 SERIES UNITS Service Literature Corp. 0610 L1 Revised 07 2006 HP13 SERIES UNITS HP13 The HP13 is a high efficiency residential split system heat pump unit, which features a scroll compressor. HP13 units are available

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories FreeZone Freeze Dry Systems a n o v e r v i e w Table of Contents: Overview................................... 1 Selection Guide.............................. 4 FreeZone

More information

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS KOOLKARE DUAL GAS UNIT The air conditioning maintenance unit KoolKare Dual Gas

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A. Service Literature Corp. 0612 L2 Revised 07 2006 13ACX SERIES UNITS 13ACX The 13ACX is a high efficiency residential split system condensing unit, which features a scroll compressor and designed for R

More information

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AIR CONDITIONING. Carrier Corporation 2002 Cat. No AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)

More information

Oil-Sealed Rotary Vane Pumps

Oil-Sealed Rotary Vane Pumps Oil-Sealed Rotary Vane Pumps P 4 Z 322002 Advantages high water vapour tolerance for chemical applications compact, robust and functional construction low noise emission no oil contamination of the chamber

More information

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

MicroTool.  Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS "Excellence in measurements" MicroTool Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS Visual/Audible Alarm Differential Manometer Differential Thermometer

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories FreeZone Freeze Dry Systems AN OVERVIEW Table of Contents: Overview...1 Selection Guide...4 FreeZone Freeze Dry Systems 1 Liter Benchtop...6 2.5 Liter Benchtop...8 2.5

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

Customized Industrial Products

Customized Industrial Products Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based

More information