1 10 Technical Data Volumes and heat loss Storage tank size Rated volume [l] Actual volume [l] Hot water standby volume [l] Economy Standard Comfort (1) 200 (1) 362 (1) Heating buffer volume [l] Solar volume [l] (2) Specific heat loss [W/K] ,11 Heat loss [kwh/24h] (3) ,95 (1) Can be selected on respective the sensor positions for "S1 storage tank top" (2) Results from the difference between the heating buffer volume + hot water volume and the actual volume (3) Applies for a storage tank temperature of 60 C and 20 C in the installation room Dimensions and performance data Component or connection Solar storage tank material Max. solar storage tank operating pressure Dimensions or values St 37-2, primed exterior, raw interior 3 bar Max. temperature in storage tank 95 C Upper/lower bleeder socket Fittings for filling and draining (corrugated pipe) Solar flow/return connection Connection for solar flow and return (Pure/Solo) Solar heat exchanger flushing unit (not for Pure/Solo) Connection for cold water and hot water Connection for heating inflow and heating return (corrugated pipe) Max. total volume flow for heating circuits Minimum circulation water quantity Pressure loss on heating water side ½" female thread 1¼" male thread/28 mm 10 mm clamping ring screw connection 1¼" male thread ½" male thread 28 mm clamp ring bracket 1¼" male thread/28 mm 2,000 l/h Max. flow temperature 75 C Not required Exhaust connection: Air supply exhaust fittings DN 125/80 No measurable pressure loss Hot water heat transfer Component or connection Values or type Fresh water heat exchanger Plate heat exchanger WWS-24, stainless steel , soldered Permitted operating pressure PWT 16 bar Hot water production circulation pump Type Wilo RS 15/7-1 Max. pressure loss on drinking water side At 1,500 l/h 0.7 bar SOLVIS SolvisMax Öl NT Subject to technical changes G 20-EN 45
2 Dimensions of the system SV ca. 850 mm SR ca. 930 mm Fig. 75: Front view Fig. 77: Side view T U ~ 555 ~ 715 ~ 860 Fig. 76: Top view Fig. 78: Tilt height 46 SolvisMax Öl NT Subject to technical changes G 20-EN SOLVIS
3 Connections on the storage tank 2 1 R Fig. 79: Schematic view of the connections 1 SolvisMax Öl NT 4 Heating return 7 Solar return 2 SolvisMax Öl NT Pur 5 Boiler filling and draining connection 8 Solar flow 3 Heating inflow 6 Flushing connections 9 Storage tank insulation Dimensions and weight Storage tank size Diameter without insulation d Diameter with insulation D ,020 1,020 Base diameter F Height without insulation h 1,511 1,761 1,833 1,823 2,213 Height with insulation H 1,600 1,850 1,930 1,920 2,290 Depth with insulation and controller T 1,375 1,375 1,485 1,535 1,535 Tilt height without insulation k 1,525 1,770 1,845 1,840 2,235 Connection dimension with insulation R ,000 1,000 Minimum clearance at front Minimum clearance at sides and to rear Height of exhaust supports DN 80 (1) A 1,334 1,626 1,626 1,626 1,626 Height of exhaust supports DN 125 (1) A 1,290 1,540 1,540 1,540 1,540 Centre of exhaust supports to back of insulation U 1,086 1,086 1,196 1,248 1,248 Condensate connection height (2) 1,063 1,313 1,313 1,313 1,313 Total weight when empty [kg] incl. insulation and protective cover All dimension specifications in mm (1) Floor to upper edge of exhaust support (2) Floor to centre of condensate connection Approx. 243 Approx. 260 Approx. 285 Approx. 291 Approx. 328 SOLVIS SolvisMax Öl NT Subject to technical changes G 20-EN 47
4 Combustion data 16 kw 17 kw Rated heat output (boiler performance) 15.7 kw 17.5 kw Rated heat load (burner performance) min.: 17 kw max.: 18 kw Standard efficiency coefficient (1) 97% 97% Boiler efficiency coefficient at 80/60 C (1) 95% 92% Exhaust temperature at 80/60 C (2) 155 C 170 C CO2 for calculating the exhaust routing 13.7% 13.5% CO standard emission factor 3 mg/kwh 5 mg/kwh NOx standard emission factor 95 mg/kwh 99 mg/kwh Soot value 0 0 Exhaust gas mass flow 7.9 g/sec 8.9 g/sec Blower pressure 2 mbar (200 Pa) 2 mbar (200 Pa) Pressure loss combustion chamber 0.15 mbar (15 Pa) 0.20 mbar (20 Pa) Diameter - supports DN 80 DN 80 Energy efficiency certification (3) Results according to certification test based on DIN 303, 304, EC Efficiency directive 92/42 EEC and and RAL-UZ 46. (1) Efficiency coefficient and utilisation ratio incl. losses for hot water production. (2) The combustion chamber thermal basin ring is freely circulated. During long burner run times, the exhaust temperature may exceed the value that is given. (3) SolvisMax Oil NT thus meets the requirements of EC Efficiency directive 92/42/EEC. Burner performance setting values Rated heat output required (boiler performance) Oil throughput * Oil nozzle Danfoss 80 S-LE Pump pressure (for checking) Rated heat load (burner performance) Measurement A approx kw 17.0 kw 1.69 l/h 0.40 gph 12.0 bar 21 mm 16.6 kw 18.0 kw 1.74 l/h 0.40 gph 13.0 bar 25 mm * The oil throughputs provided relate to a viscosity of approx. 1.8 cst with preheated heating oil. Acoustic emissions 16 kw 17 kw Without silencer 75 db (A) 76 db (A) With silencer from the ÖAS package 64 db (A) 65 db (A) With silencer from the ÖAS package and absorption-type silencer 57 db (A) 58 db (A) Electrical power consumption Designation Slumber mode Solar pump (speed-dependent) Hot water pump (speed-dependent) Circulation pump Heating circuit pump max. burner power consumption at 16/17 kw Power consumption 5 W Rated output 60 W (not for Pur / Solo) Rated output 132 W On site On site 175/181 W * Average of the power consumption in partial load operation (according to RAL UZ 46) 16/17 kw 69/72 W * 16/17 kw * electrical power consumption with blower, without pump. The electrical power consumption depends, among other things, on the height and type of exhaust system. For large heights, the max. power consumption can be up to 25 W greater. The average is then 8 W greater. 48 SolvisMax Öl NT Subject to technical changes G 20-EN SOLVIS
5 Equipment with integrated solar station* System component Values/type Solar circuit pump Vane pump Adjusting valve Adjusting valve DN 15, 1 to 4 l/min Bleeder Manual Manometer 0 to 6 bar Solar safety valve 4 bar, DN 15 Solar circuit pressure switch Switching point at < 0.8 bar Solar heat exchanger Cu pipe bundle heat exchanger integrated in stratified charger Solar heat exchanger liquid contents 0.5 l * See sec. "System Versions", p. 6 Safety technology Component Storage tank top (sensor S1) Mechanical safety temperature limiter (mstl) Flame monitor Function Monitor function for boiler temperature > 95 C (automatically switches on again when the temperature decreases to < 90 C; factory setting) Limiter function for boiler temperature > 105 C (can only be unlocked manually at the mstl, see Fig. 32, p. 18); function for water shortage and overtemperature Infrared flicker detector = flame detection Qualifications Designation CE marking Explanation CE-0085 AS0388 SolvisControl Technical Data Connection, component, function Mains voltage Properties, values 230 V~ / Hz Micro-fuse M 6.3 A / 230 V~ T 1.0 A / 230 V~ Ambient temperature 0 50 C Rated current load Power consumption Timer function without power supply Housing protection class IP 30 A1, A2, A6, A7: each 230 V~ / 1 A, relay outputs max. each 230 V~ / 3 A, sum of currents should not exceed 6.3 A Approx. 5 W (in slumber mode, without pumps) Power reserve for 1 2 days Temperature sensor type PTC 2 kohm (except the solar flow and return, outdoor sensor: Pt 1000) Temperature display -35 to +250 C Display resolution 0.1 K Measurement accuracy ± 1 K in the range from C Display 250 Display 35 Rev controller Switch output 230 V~ Analogue output 0-10 V = Sensor not connected, sensor or cable breakage Sensor short circuit A1: Phase angle control or impulse packet A2, A6 and A7: impulse packet A1 to A13: 230 V~, A14 floating O1 O3 Anti-skid control* Heating circuit pumps (user-defined for A1 A14, factory setting: off) * Anti-skid control: the heating circuit pumps can be individually set on the SolvisControl in such a way that they run on specific days for a certain amount of time. Time and duration can be changed. Resistance measured values of the temperature sensors Sensors that are not connected have resistance values that are shown in the table at various temperatures. The resistance values can be checked with a measuring device if a defective sensor is suspected. SOLVIS SolvisMax Öl NT Subject to technical changes G 20-EN 49
6 Pt1000 Temperature [ C] Resistance [Ω] 961 1,000 1,039 1,078 1,097 1,117 1,155 1,194 1,232 Temperature [ C] Resistance [Ω] 1,271 1,309 1,347 1,385 1,423 1,461 1,498 1,536 1,573 PTC (2 kω) Temperature [ C] Resistance [Ω] 1,495 1,630 1,772 1,922 2,000 2,080 2,245 2,417 2,597 Temperature [ C] Resistance [Ω] 2,785 2,980 3,182 3,392 3,607 3,817 3,915 4,008 4,166 Sensor types and their application Pt 1000 Solar flow, solar return, outdoor sensor PTC (2 kω) All other sensors 50 SolvisMax Öl NT Subject to technical changes G 20-EN SOLVIS
Economy Standard Comfort. Heat loss (W/K) Heat loss (kwh/24h) (3)
4 Technical Data The following tables and drawings provide an overview of the most important dimensions and properties of Solvis- Max Gas and SolvisMax Gas Pur. 4.1 Volumes and heat loss SX-356 SX-456
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationVD 53 - Vacuum drying oven for non-flammable solvents
Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat
More informationWOLF GAS CONDENSING BOILERS COMFORTLINE
WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationSimple solutions are usually the best...
Simple solutions are usually the best... The new heating system. SolvisMax. Energy Globe Award 2003: More than 1,000 candidates from 95 countries competed. Solvis took the prize.... 2 We really just wanted
More information24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.
24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers
More informationTechnical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW
Technical documentation ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW ComfortLine gas condensing boilers Benefits of the WOLF gas condensing boilers up to 24 kw CGB-2(K) / CGW-2 / CGS-2
More informationInstallation Plan. Professional Dishwasher PG Mat. no.: en - US
Installation Plan Professional Dishwasher PG 8056 Mat. no.: 10 251 400 en - US Installation instruction Observe installation instructions when installing machine. This dishwasher is suitable for residential
More informationStokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing
Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020
More informationMetropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h
Metropolitan Steam Boiler Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing Outputs 1845-21 700 kg/h 1 Metropolitan - Steam Boiler The Metropolitan is a range of high pressure
More informationInstallation Plan. Professional Dishwasher PG Mat. no.: en - US
Installation Plan Professional Dishwasher PG 8061 Mat. no.: 09 838 370 en - US Installation instruction Observe installation instructions when installing machine. This dishwasher is only suitable for commercial
More informationTWO STAGE HEAVY OIL BURNERS
TWO STAGE HEAVY OIL BURNERS PRESS N SERIES PRESS 30 N 85/171 342 kw PRESS 45 N 114/205 513 kw PRESS 60 N 171/342 684 kw PRESS 100 N 285/490 1140 kw The PRESS N series of burners covers a firing range from
More informationECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT
ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com
More informationThe competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28
The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More informationQuinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission
The New Remeha Quinta Pro Range Condensing Boilers REMEHA QUINTA PRO RANGE HIGH EFFICIENCY 110% NCV AT 40/30 C FULLY MODULATING BOILER CONTROL PREMIX BURNER CLEAN COMBUSTION ULTRA LOW NOx BREEAM EXCELLENT
More informationWOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE
WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE CGB-2(K) / CGW-2 / CGS-2L / CGS-2R / CSZ-2 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial
More informationLOW NOx MODULATING GAS BURNERS
RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw
More informationSelf-learning Room Temperature Controller
2 226 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch and possibility of remote control RAV12 Mains powered room temperature controller featuring straightforward operation.
More information24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus
24-28 kw Conventional Combi Gas Boiler Lawa / LawaPlus Conventional Combi Gas Boilers Warmhaus wall-hung gas combi boilers Lawa and LawaPlus, with the advantage of its width as 288mm, are easily fit to
More informationSelf-learning Room Temperature Controller
2 224 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch RAV11 Mains-independent room temperature controller featuring straightforward operation. Self-learning two-position
More informationCalder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model
Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder
More informationSuperior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw
Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency
More informationABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.
Flame scanner for fuel oil and coal flame (rev. A) Application: - Wall fired, corner fired and down-shot boilers - Oil, Orimulsion and pulverized coal burners PbS sensor to detect flame by infrared (IR)
More informationLogamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.
Technical Guide Issue 2011/06 Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein. Sie finden die Bilder auf der Referenzseite 14: Buderus Product groups. Anordnung im Rahmen: - Tops
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)
Dual sensor flame scanner (rev B) Application: - Wall fired and corner fired boilers - Gas, oil and coal multi-fuel burners Combined PbS IR sensor and high sensitivity UV tube Continuous self-checking
More information*24168* Art. Nr.: P20-EN Subject to technical changes. SolvisStrato Installation. Stratified buffer tank
SolvisStrato Installation Stratified buffer tank Type sizes: SR-727, SR-917, SR-1427 and SR-1817 Installation Start-Up Maintenance *24168* Art. Nr.: 24168 P20-EN Subject to technical changes 11.13 / 24168-3c
More informationSelf-learning Room Temperature Controller
2 252 Self-learning Room emperature Controller with one weekly operating mode including individual 24-hour modes and three 24-hour modes, cooling function REV22 Use Mains-independent room temperature controller
More informationCAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL
BRILEY CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER 60 140 kw 0604.2 Beeston Briley cast-iron premix gas-fired boiler 60-140kW Contents 1 Boiler specifications Page 3 2 Appliance general dimensions
More informationInfrared Diesel Heater
Infrared Diesel Heater Model No: IRD40 PART NO: 6920415 OPERATING & MAINTENANCE INSTRUCTIONS GC0812 INTRODUCTION Thank you for purchasing this CLARKE Diesel Infrared Heater. Before attempting to use the
More information24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.
combi boilers panel radiators 24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus www.warmhaus.com 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-33/40 kw Warmhaus
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More informationEOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION
EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION AXIAL FANS AND CENTRIFUGAL FANS HEATING COOLING GREEN ENERGY EOLO VIP: NEW! VERY IMPORTANT PERFORMANCE The
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationFloorstanding Gas Condensing Boilers VITOCROSSAL 100
Floorstanding Gas Condensing Boilers VITOCROSSAL 00 Heating systems Industrial systems Refrigeration systems Floorstanding Gas Condensing Boilers Vitocrossal 80 to 8 kw Cascade up to 66 kw / VITOCROSSAL
More informationSelf-learning Room Temperature Controller
Self-learning Room emperature Controller with two 24-hour operating modes Mains-independent room temperature controller featuring straightforward operation and an easy-to-read display. Self-learning two-position
More informationUV Flame Supervision System
7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running
More informationin/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)
CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded
More informationHIGH OUTPUT. Skin design RANGE
Light drop design HIGH OUTPUT Skin design RANGE Trim design 1 Product Introduction Product Presence Worlwide 2 Product Presentation Bosch Model Commercial Name: GWHC 27 3 Product Presentation Product Design
More informationENERGY TOP. Condensing boiler solutions
ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for
More informationCalder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model
Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency
More informationDivacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production
Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation
More informationAir curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain
Air curtains 114 MRX condensing gas air curtain 118 MRA-H gas air curtain 121 MRA-A ventilation only air curtain 122 SW / SE hot water / electrical air curtain 124 SWR / SER built-in hot water / electrical
More informationCIRCO 6 Solar Circulation Unit
TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a
More informationEUQA Humidifier, for circulated water
Sizes 0 4, 50, 5 Sizes 44, 5 84 6 5 4 6 5 4 5 6 8 7 9 7 8 0. Control box, on the outside. Control box, on the inside. Shut-off valve (not included) 4. Water filter, max. 500 mm mesh (not included) 5. EUAZ-08
More informationWALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C
ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on
More informationSPECIFICATIONS - NIKE
Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks
More informationInstallation manual Operating instructions
WIKORA GmbH Friedrichstr. 9 89568 Hermaringen Phone: (07322) 9605-0 Fax: (07322) 9605-30 email: contact@wikora.de Installation manual Operating instructions DHW storage tank UNO/DUO/H/WPSOL Installation
More informationProduct Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S
D10 is a type-approved measuring device which combines the advantages of the measuring principles transmittance and scattered light forward. Therefore, it is ideal for measurement of very low to high dust
More informationData sheet: Wilo-RainSystem AF Comfort MC 304
Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater
More informationAGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING
MADE IN ITALY residential condensing D.H.W. up to 10 bar WORKING PRESSURE AISI 316 Ti TITANIUM D.H.W. 100% CONDENSING AGUAdens TM wall-mounted water heaters (16-22 -37 litres) AGUAdensTM INSTANTANEOUS
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationVIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.
VIESMANN VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW Datasheet Part no. and prices on request VITOMAX 200-LW Type M64A
More informationproduct Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners
product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt
More informationECONOFLAME R6000 GAS FIRED CONDENSING BOILERS (KM628 CONTROLLER)
ECONOFLAME R6000 GAS FIRED CONDENSING BOILERS (KM628 CONTROLLER) INSTALLATION, OPERATION & MAINTENANCE DOCUMENTATION STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 8783 3050
More informationComfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W
Comfort Ceiling Fan Coil System INDULVENT ec NEW Draught-free ambient air distribution with cooling capacity up to 2600 W Low sound power levels Only electrical, cooling water and condensate connections
More informationVIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l
Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these
More informationConstant climate chambers
Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the
More informationVIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17
VIESMANN VITOCELL 300-V Vertical DHW cylinder 130to500litrecapacity Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 17 VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder
More informationVIESMANN. Installation instructions VITOMAX 200-HW. for contractors
Installation instructions for contractors VIESMANN Vitomax 200-HW Type M238 Oil/gas fired high pressure hot water boiler Combustion output 4.0 to 18.2 MW VITOMAX 200-HW 6/2007 Dispose after installation.
More informationRoom sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23
Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,
More informationHYDRONIC L-II Troubleshooting and Repair Instructions
HYDRONIC L-II Troubleshooting and Repair Instructions Normal version Compact version Heater Order No. normal version Order No. compact version Hydronic L 16 25 2486 02 00 00 Hydronic L 24 25 2487 02 00
More informationWeekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.
Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide. SHORT DESCRIPTION: 1. Device is applicable to: - Burners; - Electric boiler;
More informationVisit us at
testo 105 Thermometer Instruction manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 1. Genaral Information 7 1. General Information
More informationhinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )
Space requirements Fig. 1: Fore view, door hinge left Fig. 2: Upper view, door hinge left (D1, D2) and door hinge right Table 1: Space requirements Cliniclave 45 Dimensions Cliniclave 45 Width Height Height
More informationREMKO HYBRID HEAT PUMPS
REMKO HYBRID HEAT PUMPS Switch over to more efficiency even in old buildings HBW series 1-2014 Quality with systems THE HYBRID TECHNOLOGY Two technologies combined into one innovation "Hybrid comes from
More informationProduct news 2018/19. Heat pump system WIKOSOL HPS. Tank for wall boiler WBO TN. Vacuum tube collector WIKOSUN HP 2340 / 1240
Product catalog 2019 Valid from 1st of April 2019 1 Product news 2018/19 Heat pump system WIKOSOL HPS Page 5 For the replacement and modernization of heaters in existing buildings Most powerful heat pump
More informationInstallation and operating instructions. DK energy storage and DK energy buffer
Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationVIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw
VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CR3B Gas condensing boiler for natural gas E, LL and LPG 9/2011 Benefits
More information24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus
24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-32/40 kw Warmhaus wall-hung gas combi boilers Priwa and PriwaPlus,
More informationVIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity
VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product
More informationVIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw
VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CT3B Gas condensing boiler for natural gas E, LL and LPG With modulating MatriX
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to
More informationBosch Uni 7000F Cast Iron Hot Water Boiler
Technical Data Sheet Bosch Uni 7000F Cast Iron Hot Water Boiler Standard Engineering Specifications The boiler(s) shall be sectional cast iron hot water boiler(s) of full three pass design, suitable for
More informationVIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW
VIESMANN VITOMAX 200-WS Hot water boiler for permissible flow temperatures up to 110 C 1.75 to 11.63 MW Datasheet Part no.: see pricelist, prices on request VITOMAX 200-WS Type M250 Oil/gas fired hot water
More informationC B SOLARTHERMAL. Solar thermal systems
66 66 Steca Elektronik GmbH 87700 Memmingen Germany Fon +49 (0) 81 8558-0 Fax +49 (0) 81 8558-12 www.stecasolar.com 67 E A D C B Legend: A Collector B Solar Station C Storage tank D Central-heating boiler
More informationInstallation plan: PG Mat. no Version 00 US
Installation plan: PG 8504 Mat. no. 10 344 110 Version 00 US Technical data sheet PG 8504 Legend: Circled, bold-type abbreviations: Connection required Abbreviations surrounded by broken circle: Connection
More informationHigh temperature hydrobox for VRV
High temperature hydrobox for VRV For efficient hot water production and space heating Air to water connection to VRV for applications such as bathrooms, sinks, underfloor heating, radiators and air handling
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationHoval TopGas (12, 16, 22)
Hoval TopGas (2, 6, 22) Wall gas condensing boiler with or without calorifier TopVal Description Hoval TopGas Boiler Wall mounted gas condensing boiler Heat-exchanger out of corrosion resistance aluminium
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A
178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle
More informationST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number
ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point
More informationGas cooler series TC-Standard+
Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationREMKO Comfort-WP The versatile heat pump
REMKO Comfort-WP The versatile heat pump Issue 2012 Independent from oil and gas Cosy heat in the winter A pleasant climate in the summer CMF Series 1-2014 Quality with systems REMKO THE CUSTOMER-ORIENTED
More informationPressure measuring instruments
Data sheet testo 312-2 / -3 / -4 Pressure measuring instruments For gas and water installers testo 312-2 testo 312-3 testo 312-4 hpa bar C www.testo.com testo 312-2 / testo 312-3 Pressure meters for gas
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R
178 013 03-2 2016-05-26 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 10 E R DESCRIPTION Components 1. Scale, nozzle assembly 2. Nozzle assembly adjustment
More informationServicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use
GB122 7210 1300-12/2002 GB(EN) For trade use Servicing manual Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C Please read thoroughly before attempting to diagnose fault List of contents
More informationSavile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h
Savile Plus Steam Boiler Suitable for Pressure Jet burners Oil, gas or dual fuel firing Outputs 380-5425 kg/h 1 Savile Plus - Steam Boiler The Savile Plus is a range of three pass wet back reverse flame
More informationPRODUCT INFORMATION. Technical description. Hygienic stratification storage tank HSK ÖKO Universal heat center for legionella safe preparation of DHW
We develop for your future! PRODUCT INFORMATION Hygienic stratification storage tank Universal heat center for legionella safe preparation of DHW Technical description Solarbayer GmbH (18.12) Solarbayer
More informationConstant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:
Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationMaximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:
Maximiser SE USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE: 705.276A-3233 11-2000 INTRODUCTION It is essential that the instructions in this booklet are strictly followed, for safe and economic
More informationRinNOVA. User manual and installation instructions
RinNOVA User manual and installation instructions Congratulations on your selection. WARNING Your modulating boiler is electronically adjusted and ignited. highly efficient sealed chamber with steel domestic
More information30 SD & 45 SD CONDENSING BOILERS
ETHOS 30 SD & 45 SD CONDENSING BOILERS Installation and Operating Manual Issue 01/07 Combustion fan CONTENTS 1 SAFETY GUIDELINES...1 1.1 Conditions...1 1.2 General guidelines...1 2 TECHNICAL DATA...2 2.1
More information