Visao HIGH-SPEED OTOLOGIC DRILL CATALOG
|
|
- Shon Reeves
- 5 years ago
- Views:
Transcription
1 Visao HIGH-SPEED OTOLOGIC DRILL CATALOG
2 Visao High-Speed Otologic Drill with the Integrated Power Console (IPC ) System High speed and torque 80,000 rpm max speed provides rapid, yet precise bone removal Cool running Water-cooled motor keeps the handpiece from overheating during long procedures 1
3 Created for neurotology 20 degree curved burs are specifically designed for working in tight, deep anatomic spaces Ergonomic Well-balanced and lightweight titanium body is easy to maneuver Extended Bur Guard with Irrigation Extended Bur Guard without Irrigation Easy assembly Snap fit reusable bur guards and quick locking burs make the Visao ideal for busy teaching institutions 2
4 Visao Curved Burs Use at speeds up to 80,000 rpm 4.0mm 3.0mm 2.0mm 90 mm E E E Fluted 115 mm E E E Flutes mm E E E Diamond 115 mm E E E Diamond Grit 120/ /170 Coarse 90 mm E E E Diamond 115 mm E E E Diamond Grit 40/0 0/80 80/100 Visao Cochleostomy Burs Use at speeds up to 80,000 rpm 2.0mm Fluted 98 mm Flutes Diamond 98 mm Diamond Grit 98 mm Curved Bur 3
5 1.5mm 1.0mm E E E 90 mm Curved Bur 1.5mm 1.0mm E E E 115 mm Curved Bur 0.mm 0.5mm E E E 325/ /400 4
6 Visao Straight Burs Use at speeds up to 80,000 rpm Medium Working Length Long Working Length 23 mm X-Long Working Length 7 mm mm 5 mm 4 mm Medium U U U U Fluted Long U U X-Long UE Flutes Medium Working Length Long Working Length 23 mm 23 mm X-Long Working Length mm 5 mm 4 mm Medium Diamond Long X-Long Diamond Grit 120/ / /140 Medium Working Length Long Working Length 23 mm X-Long Working Length mm 5 mm 4 mm Medium Coarse Long Diamond X-Long Diamond Grit 40/0 40/0 40/0 5
7 3.5 mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm UE UE UE U U UE UE mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm 0.5 mm / / / mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm /80 0/80 80/ / /170 0/80
8 Other Shape Burs Other Shape Burs 1 per box Use at speeds up to 52,000 rpm Acorn Fluted Oval Fluted Pear Fluted Pear Coarse Diamond.9 mm.0 mm 5.0 mm 5.5 mm.0 mm.0 mm Medium Long Flutes Grit 100/120 7
9 8
10 Ordering Ordering Information Information Integrated Power Console Integrated Power Console Multifunction Footpedal Visao High-Speed Otologic Drill Visao High-Speed Otologic Drill Extended Bur Guard Without irrigation Visao High-Speed Otologic Drill Extended Bur Guard With irrigation Visao High-Speed Otologic Drill Sterilization Tray US Power Cord, meter Pole Basket for Footswitch Irrigation Tubing Set, Sterile, 4/box Hi-Speed Drill Coolant Tubing Set, 2/bx 9
11 Visao High-Speed Otologic Drill Cleaning and Sterilization Instructions These products must be available for proper cleaning of the Visao drill: , Medtronic ENT Cleaning Solution, 1 each , Chuck Brush Cleaner, 0/pack Complete these steps. 1. Prior to sterilization, wipe the drill and cable with a clean cloth soaked in enzymatic detergent solution. (Medtronic ENT Cleaning Solution and distilled water are recommended for best results.) 2. A chuck brush cleaner ( ) or appropriately sized bristle brush may be inserted into the distal end of the Visao drill, irrigation sleeves and bur guards. 3. Rinse out the distal end of the drill. DO NOT IMMERSE! Shake out excess water. Rinse the irrigation nozzles and motor housing after use (distilled water is recommended for best results). 4. Clean and dry the instrument tray. 5. Dry the drill, cable, irrigation sleeve and bur guards thoroughly. Place them in their respective slots in the instrument tray. Automated Cleaning validation consists of a minimum 44 minute total time; including pre-wash; main wash and rinse; and thermal rinse. Thermal rinse shall be at least 10 minutes long at a minimum temperature of 0º. Warnings 1. Do not immerse! 2. Do not use an ultrasonic cleaner! 3. Do not use organic solvents, such as isopropyl alcohol or acetone, to clean drill! 4. Heating above 149 C (300 F) may damage the handpiece and will void the warranty. Sterilization Exposure Times Steam Autoclave/Gravity 121 C minimum (250 F) 40 minute cycle, minimum 8 minutes dry time (or until visibly dry) Steam Autoclave/Pre-Vacuum 132 C minimum (270 F) 4 minute cycle, minimum 8 minutes dry time (or until visibly dry) Sterrad Sterilization (Sterrad 100S compatible) Only the drill is compatible Irrigation sleeves and bur guards are not compatible Ethylene Oxide Concentration: 00+/-25mg/L Sterilization: 54 C to 55 C (129 F to 131 F) Relative Humidity: 0+/-5% Aeration: 48 C to 52 C (118 F to 12 F) for 8 hours Exposure Time: (full cycle) 120 minutes Wrap: A standard, sterilization wrap may be used. In the US, an FDA approved surgical wrap must be used. Wrap tray using appropriate method. Ensure that the pack is large enough to contain the instrument without stressing the seals. Instruments may be loaded into dedicated instrument trays or general purpose sterilization trays. Ensure that cutting edges are protected. 10
12 For more information, contact your Medtronic NT sales representative or refer to Medtronic Powered Surgical Solutions 420 North Beach Street Fort Worth, TX 7137 USA Internet: Telephone: Toll-free: Fax: AUTHORIZED REPRESENTATIVE IN EU: Medtronic B.V. Earl Bakkenstraat 10, 422 PJ Heerlen The Netherlands Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. Refer to product package insert for instructions, warnings, precautions and complications. LIT250021EN.RNew 2008, Medtronic, Inc. Registered mark of Medtronic, Inc.
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine
More informationEMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications
EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications TABLE OF CONTENTS MANUAL PRE-CLEANING High Speed Handpieces 2
More informationCleaning & Sterilization
Handpieces & Attachments Instruments Cleaning & Sterilization System 7 System 6 System 5 CD4 CD3 SABO 2 SABO RemB CORE TPS Processing Instructions User/Patient Safety all contribute to the efficacy of
More informationCONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization
CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling
More informationManual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files
Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files Cautions Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine
More informationIMPORTANT INFORMATION ON THE DEPUY SYNTHES
For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE DEPUY SYNTHES MatrixNEURO RECONSTRUCTION MESH, STERILE MatrixNEURO PREFORMED MESH, STERILE GP2949-B-CAN DESCRIPTION The DePuy Synthes
More informationCONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization
CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling
More informationMade in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)
Fiber Optic Cables Instructions for Use and Processing Instructions DFU-950-0031-00 Fiber Optic Cables Made in USA Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904) 737 7611
More informationManual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches
Caution Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine content.
More informationCONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization
CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray Equipment Cleaning and Sterilization Table of Contents 1. WARNINGS AND PRECAUTIONS... 3 2. INSTRUMENT PREPARATION... 3 3. CAVITY PREPARATION
More informationHIGH SPEED DRILL SYSTEM Instructions for Use. BUSAMedical.com
HIGH SPEED DRILL SYSTEM Instructions for Use BUSAMedical.com TABLE OF CONTENTS Introduction PAGE 3 Intended Use PAGE 3 Explanation of Symbols PAGE 4 Set-up Illustration PAGE 5 Drill Motor Setup PAGE 6
More informationReusable Laryngoscope Blades and Handles
Manufacturer: Starkling Medizintechnik Method: Re-processing instructions Symbol: N.A. Device(s): 1 Green System Reusable Laryngoscope Blade with integrated Light Guide, Solid Stainless Steel Construction
More informationV. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only
V. Mueller en V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA Rx Only V. Mueller, CareFusion and the CareFusion logo are trademarks or registered trademarks of CareFusion Corporation
More informationOperating / User Manual
UniARM Surgical Support System Operating / User Manual Version 1.1 MITAKA KOHKI Co., Ltd. 1. Introduction Introduction Thank you for purchasing the UniARM for use in surgical procedures. To use the device
More informationRigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.
Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1 ENGLISH Intended Use The Welch Allyn Rigid Reusable & Single Use Sigmoidoscopes and Anoscopes are used to illuminate and
More informationOperator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M
Operator s Guide Autoclavable Internal Handles with Integrated Paddles 9650-0550 Rev. M The issue date for the Autoclavable Internal Handles with Integrated Paddles Operator s Guide (REF 9650-0550 Rev.
More informationAS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/
General Information Use The Air drill System is a pneumatic powered system used for many applications orthopedic and trauma surgery. To ensure proper operation of the air drill, use only original attachment
More informationCLEANING INSTRUCTIONS
Reusable Instrument Care Manual Pagoda Pedicle Screw System Manufacturer Ortho Development Corporation 12187 South Business Park Drive Draper, UT 84020 Phone 801-553-9991 Fax 801-553-9993 www.orthodevelopment.com
More informationAccessories. Maybachstraße. Symmetry Fax: Revised 10/15
Recommended Care, Cleaning and Sterilization Instructions for Reusable Instruments & Accessories Symmetry Surgical Inc. 3034 Owen Drive, Antioch, TN 37013 USA 1-800-251-3000 Fax: 1-615-964-5566 www.symmetrysurgical.com
More informationSKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS
SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS CAUTION: The following instructions are for all Sklar Coated stainless steel instruments. Read instructions prior to use. Improper
More informationX99 Series. Dental Handpiece. Instruction For Use
X99 Series Dental Handpiece Instruction For Use 0413 Table of Contents Symbols... 2 Introduction... 3-4 Before Use... 5 Product description... 6 Technical Specifications... 7 Operation... 8-11 Hygienic
More informationUser s Manual. Small Electric Drive. Compact and powerful system for use in hand and foot surgery.
User s Manual Small Electric Drive. Compact and powerful system for use in hand and foot surgery. Table of Contents Introduction General Information 1 Consoles General Description 4 Set-up 6 Small Electric
More informationInstructions for Use Spinal Punches IFU
Indications for use Spinal punches are manually operated instruments indicated for cutting or biting bone during surgery involving the skull or spinal column. Contraindiciations Instruments should not
More informationSTERITITE INSTRUCTIONS FOR USE
STERITITE INSTRUCTIONS FOR USE If a rigid container system is used, the manufacturers instructions regarding set preparation and assembly should be followed. -ANSI/AAMI ST79: 2010 & A1:2010 Notes from
More informationidrive Ultra Powered Stapling System
idrive Ultra Powered Stapling System Product Information Kit Stapling Made Smarter Table of Contents Product Introduction 2 System Introduction 3 Features and Benefits 4 System Components 5 Tri-Staple
More informationInstructions for Use: Fiberscope and LED Light Source
Instructions for Use: and Brand Name of Product Generic Name of Product Product Code Number(s) Intended Use Range of Applications for Product Key Specifications of Product, FBR-001, FBR-002, FBR-ULB-100,
More informationCleaning and Sterilization for Instruments & Posts
Cleaning and Sterilization for Instruments & Posts EN FOR DENTAL USE ONLY CLEANING AND STERILIZATION PROCEDURE FOR ENDODONTIC FILES, HAND INSTRUMENTS, PINS AND POSTS, STAINLESS STEEL DRILLS, STAINLESS
More informationINSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)
INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS) 1 INTRODUCTION This paper is intended to give general
More informationUser Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories
User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories Table of Contents 1. Intended Use Statement... 3 2. Proper Use... 3 3. General Information...
More informationI.F.U Re/Processing Reusable Medical Devices
I.F.U Re/Processing Reusable Medical Devices Distributed by: MANUFACTURER: GA 26-09-001 -EN /20130719 Contents 1 Overview of preparation methods... 3 2 Safety and responsibility... 4 3 Explanation of symbols...
More informationIntegra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions
Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing Instructions for Use. Description and Intended Use Integra LifeSciences Corporation reusable surgical device sets consist of various
More informationINSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS
INSTRUCTIONS FOR USE & STERILIZATION PMS PRECISION MEDICAL SPECIALITIES GMBH Kreuzstrasse 5 DE-78532 Tuttlingen PO Box 4607 DE-78511 Tuttlingen Fon: +49 74 61 13 131 Fax: +49 74 61 76 698 info@pms-tuttlingen.de
More informationComPact Air Drive II USER S MANUAL
ComPact Air Drive II USER S MANUAL R Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF TABLE OF CONTENTS Page ComPact Air Drive II Specifications... 2 Attachments...
More informationNIM-Response 3.0 NERVE INTEGRITY MONITORING SYSTEM
NIM-Response 3.0 NERVE INTEGRITY MONITORING SYSTEM NIM-Response 3.0 System Leading Through Innovation. To help improve patient safety and surgeon peace-of-mind, Medtronic ENT introduced the first NIM intraoperative
More informationInstructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices
Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices 71381339 REVA CLEANING AND STERILIZATION BRO.indd 1 5/21/12 3:41 PM 71381339 REVA CLEANING AND STERILIZATION
More informationOperator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013
Video Laryngoscope Operator s Manual ( Instructions for use ) Doc no: 100-160-000 Revision 1.1 8th January 2013 Aircraft Medical Ltd 2012 www.aircraftmedical.com Contents 1 Introduction 2 1.1 Description
More informationChristina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK
Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK Irrespective of where the decontamination is performed or who it is performed by the
More information*smith&nephew VERSAJET HYDROSURGERY SYSTEM
Product Manual Manuel D utilisation Bedienungshandbuch Manual Del Producto Manuale Prodotto Producthandleiding *smith&nephew VERSAJET HYDROSURGERY SYSTEM VERSAJET Hydrosurgery System Product Manual Contents
More informationVMS+ Cleaning and Disinfection Guide
VMS+ Cleaning and Disinfection Guide This, as well as the software described in it, are furnished under a software license agreement ( Agreement ) and may be used or copied only in accordance with the
More informationINSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE
Single use soft brush (MAJ-1888) INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE OLYMPUS TJF TYPE Q180V Accessories: Water resistant cap (MH-553) Biopsy valve (MB-358) Air/water valve (MH-438) Suction cleaning
More informationINSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE
INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF TYPE XP160 OLYMPUS GIF TYPE 160 OLYMPUS GIF TYPE Q160 OLYMPUS GIF TYPE Q160Z OLYMPUS GIF TYPE 1TQ160 OLYMPUS GIF TYPE XTQ160 EVIS EXERA COLONOVIDEOSCOPE
More informationWARNINGS AND PRECAUTIONS FOR THE USE OF THE IQ TM Intelligent Driver
0086 1520 Tradeport Drive 01-50-1450 Jacksonville, FL 32218-2480 Revision: A Tel 904-741-4400 FAX 904-741-4500 Date: 4/2013 WARNINGS AND PRECAUTIONS FOR THE USE OF THE IQ TM Intelligent Driver ATTENTION
More informationCleaning and Sterilisation for Burs, accessories and filling material
Cleaning and Sterilisation for Burs, accessories and filling material EN FOR DENTAL USE ONLY CLEANING AND STERILISATION PROCEDURE FOR BURS, ACCESSORIES AND FILLING MATERIAL 1) FOREWORD Devices that are
More informationINSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE
Single use soft brush (MAJ-1888) INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE OLYMPUS TJF TYPE Q180V Accessories: Water resistant cap (MH-553) Biopsy valve (MB-358) Air/water valve (MH-438) Suction cleaning
More informationOPERATION AND MAINTENANCE MANUAL
OPERATION AND MAINTENANCE MANUAL ADU-10CF (NSN: 6520-01-456-7170) Part 1 of 2 P.O. Box 1548 Woodinville, WA 98072-1548 1-800-426-5913 * 425-487-3157 * Fax: 425-487-2608 email: info@aseptico.com * Internet:
More information2015 Myco Industries, Inc Fax:
Endoscope Cleaning and Handling It is highly important that you manually clean the endoscope immediately after it is removed from the patient, BEFORE it is automated or manually disinfected. Cleaning your
More informationRapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times
Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times USER MANUAL MODELS: COX 115V-N COX 220V-N COX 115V-R COX 220V-R 2364 Leicester Road, P.O. Box 175, Leicester, NY 14481 Phone (585)
More informationCavitator Ultrasonic Cleaner Instruction Manual Model 20G
Cavitator Ultrasonic Cleaner Instruction Manual Model 20G Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationUSER GUIDE STEAM MOP STEAMREADY 1464 SERIES
STEAMREADY STEAM MOP USER GUIDE 1464 SERIES IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING YOUR STEAM MOP. When using an electrical appliance, basic precautions should be observed, including
More informationCavitator Ultrasonic Cleaner Instruction Manual
Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationAS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/
s 65-201-00-65-202-00 01 Stopcock left 02 Spring Cap 03 Cannula CLEANING / STERILIZATION Immediately after use the instruments have to be soaked in a combined disinfection and cleaning solution in order
More informationUse and Care Guide. Over the Patient Units and Swing Mount Units
Over the Patient Units and Swing Mount Units Table of Contents Page General Information 2 Operation 3-5 Dental Unit Adjustments 6-10 Cleaning, Disinfecting and Sterilization 11-12 Maintenance 13-15 Page
More informationFLASH PAK STERILIZATION CONTAINER SYSTEM
INSTRUCTIONS FOR USE FLASH PAK STERILIZATION CONTAINER SYSTEM Description The Flash Pak Sterilization Container System consists of a family of rigid reusable containers that provide an effective sterilization
More informationCLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L
1 2 Ideal for cleaning surgical, medical, dental instruments and equipment. Available in various sizes. Before placing instruments into the Ultrasonic Cleaner a degas cycle should be run. Then a clinical
More informationOPERATION MANUAL. (Cleaning, Disinfection and Storage) Endoscope ED-530XT
US Endoscope ED-530XT OPERATION MANUAL (Cleaning, Disinfection and Storage) Thank you for purchasing our product. Read this manual carefully before use to avoid unexpected accidents and to take full advantage
More informationTable of Contents. English
OM-E0799E 000 English Thank you for purchasing VIVA ace Motor Kit. Please read this Operation Manual and the VIVA ace Basic Set Operation Manual carefully before use for operating instructions and care
More informationAdditionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.
Reprocessing of Dental Hand Instruments and Accessories 1.0 Fundamental points All instruments are to be cleaned, disinfected, and sterilized prior to each use. In addition, cleaning, disinfection and
More informationOperator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes
Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741
More informationInstructions for Use A-dec Self-Contained Water System
Instructions for Use A-dec Self-Contained Water System The self-contained water system supplies water to handpieces, syringes, and the cuspidor cupfill. The system includes a 2- or 0.7-liter water bottle
More informationPOWEREDGE LIFT-OFF STEAM MOP USER GUIDE 2078 SERIES
POWEREDGE LIFT-OFF STEAM MOP USER GUIDE 2078 SERIES IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING YOUR STEAM MOP. When using an electrical appliance, basic precautions should be observed,
More informationTrauma Recon System (TRS). Battery-driven Power System designed for traumatology and arthroplasty.
Trauma Recon System (TRS). Battery-driven Power System designed for traumatology and arthroplasty. Instructions for Use This publication is not intended for distribution in the USA. Instruments and implants
More informationAttendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.
THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED
More informationProcessing Instructions. Cleaning so easy.
EN Processing Instructions. Cleaning so easy. 2 A good decision. Congratulations on your new tiologic easyclean Wash-Tray. Machine treatment of the entire instrument set is an essential component of quality
More informationSterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System
SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System This document contains Instructions for Use regarding the processing of the SterilContainer S prior to sterilization
More information6 things to consider. when designing your steri-center
6 things to consider when designing your steri-center Does your steri-center meet SciCan s SPECs? Here are six important areas to address to ensure you meet these standards. 2 The steri-center is definitely
More informationFiona Collins Liliana Donatelli Andrew Smith
Fiona Collins Liliana Donatelli Andrew Smith DISCLOSURE STATEMENT The presenters have no conflict of interest regarding the content of this presentation Develop a database for various countries globally
More informationRECOMMENDATIONS FOR CLEANING DEVICES
RECOMMENDATIONS FOR CLEANING D E C O N TA M I N AT I O N A N D S T E R I L I Z AT I O N O F M E D A C T A I N T E R N A T I O N A L O R T H O P E D I C DEVICES 1 This document was prepared to provide cleaning,
More informationON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)
THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED
More informationBest practices in Cleaning and Safety
Best practices in Cleaning and Safety Agenda Cleaning/maintenance of equipment Safety precautions Cleaning/maintenance of consumables Cleaning of specimens Other tips and tricks Cleaning/maintenance of
More informationCare instructions ESTETICA E80. Always be on the safe side.
Care instructions ESTETICA E80 Always be on the safe side. Distributed by: KaVo Dental GmbH Bismarckring 39 D-88400 Biberach Tel. +49 7351 56-0 Fax +49 7351 56-1488 Manufacturer: Kaltenbach & Voigt GmbH
More informationUSING THE REFRIGERATOR COMPARTMENT
USING THE REFRIGERATOR COMPARTMENT Switching the appliance on Starting the appliance Insert the plug. The light, located under the control panel or inside the product (depending on model) comes on when
More informationCavitron Systems, Sterilizable Handpieces and Reservoir Bottles INFECTION CONTROL PROCEDURES
Cavitron Systems, Sterilizable Handpieces and Reservoir Bottles INFECTION CONTROL PROCEDURES Systèmes Cavitron, pièces à main stérilisables et flacons-réservoirs. PROCÉDURES DE CONTRÔLE DES INFECTIONS
More informationCLEANING AND HANDLING OF WRIGHT INSTRUMENTS
CLEANING AND HANDLING OF WRIGHT INSTRUMENTS 150824-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt)
More informationUser Manual J0841X. Piezo Electric Ultrasonic Scaler / Polisher Combo Unit. Jorgensen Laboratories, Inc.
User Manual J0841X Piezo Electric Ultrasonic Scaler / Polisher Combo Unit Jorgensen Laboratories, Inc. www.jorvet.com Email: info@jorvet.com 1 Thank you for choosing Jorgensen s Piezo Electric Scaler/Polisher
More informationSUS-12 Steam Cleaner User Manual
SUS-12 Steam Cleaner User Manual Steam Cleaner SUS-12 User Manual IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using your Steam Cleaner. When using an electrical appliance, basic precautions
More informationEZ9Plus & EZ11Plus Instructions on: Operating
EZ9Plus & EZ11Plus Instructions on: Operating Step 1 Turn the unit on by setting the rocker switch mounted on the right side of the front panel to the On position. NOTE: The EZ11Plus has an automatic pre-heating
More informationCaution: Federal U.S. law restricts this device to sale by or on the order of a physician.
Reprocessing Manual Fuse 1C Colonoscope Part Number FSE-056-EN-2.00 Released August, 2013. This manual includes complete reprocessing instructions for the Fuse 1C Colonoscope system. Please refer to the
More informationCavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationπ H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com
π H-2268 SANITAIRE UPRIGHT VACUUM 1-800-295-5510 uline.com SAFETY PAGE 1 OF 7 NOTE: When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS
More informationVMS+ Cleaning and Disinfection Guide
VMS+ Cleaning and Disinfection Guide This, as well as the software described in it, are furnished under a software license agreement ( Agreement ) and may be used or copied only in accordance with the
More informationPrinciples and Techniques of Instrument Processing and Sterilization
Principles and Techniques of Instrument Processing and Sterilization Chapter 21 Copyright 2018, Elsevier Inc. All Rights Reserved. 1 Learning Objectives Lesson 21.1: CDC Guidelines 1. Pronounce, define,
More informationAesculap Implant Systems
Aesculap Implant Systems Aesculap Implant Systems Orthopedics USA Instructions for Use/Technical Description Page 1 of 14 Symbols on product packages Caution, general warning symbol Caution, see documentation
More informationINSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES
INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES Contents: Pagina 1 Introduction...2 2 Treatment instructions...2 3 Cleaning...2 3.1 Place of use...4
More informationGuidelines for cleaning, disinfection, and sterilization of the biopsy adaptor, water bag, coupler, and magnetic sensor securing adaptor
Guidelines for cleaning, disinfection, and sterilization of the biopsy adaptor, water bag, coupler, and magnetic sensor securing adaptor This manual describes the procedures for cleaning, disinfecting,
More informationPINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS
PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS Instructions For Use Overview MKT 15-10AECIFU Rev 4/15 1 PURPOSE OF THE PINNACLE AEC TEST The test is to be used to monitor the effectiveness
More informationUser Manual J841Q. Magnetostrictive Scaler / Polisher Combo Unit. Jorgensen Laboratories Tel: Fax:
User Manual J841Q Magnetostrictive Scaler / Polisher Combo Unit Jorgensen Laboratories Tel: 800-525-5614 Fax: 970-663-5042 Email: jortech@jorvet.com 1 Warnings Important Notes! The equipment is only to
More informationWhen you sterilize an instrument set, you know what the standards are.
Sterilization & Infection Control The importance of cleaning in earnest A regular column on sterilization and infection control issues. When you sterilize an instrument set, you know what the standards
More informationINSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER
INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings 2 Installation Instructions 3 Wiring Instructions 3 Outdoor
More informationSteam Mop USER S GUIDE 1867 SERIES. 3 Safety Instructions. Product View. Assembly 5-6. Special Features. Operation 7-8. Maintenance and Care 8-9
Steam Mop USER S GUIDE 1867 SERIES 3 Safety Instructions 4 Product View 5-6 Assembly 6 Special Features 7-8 Operation 8-9 Maintenance and Care 9 Troubleshooting 10 Consumer Services 11 Replacement Parts
More informationOperator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes
Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482
More informationRecommendations for cleaning, decontamination and sterilisation. devices
Recommendations for cleaning, decontamination and sterilisation of MEDACTa INTERNATIONAL orthopedic devices 1 This document was prepared to provide cleaning, decontaminating and sterilising instructions
More informationFlexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.
Flexible Nasopharyngoscope Operator Manual Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc. 1. Introduction The flexible nasopharyngoscope is sold in unsterile condition as a reusable
More informationEL400 OPERATION MANUAL
All Titanium Body Micromotor System EL400 OPERATION MANUAL 40,000min -1 (rpm) OM-E0078E Rev.3 Please read this operation manual carefully before use and keep for future reference. Classification of equipment
More informationWarnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6
TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4-5 Replacement Element Installation 5 Replacement Parts 5-6 Heater Coverage Areas 6 General Notes 6
More informationCLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information
CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL Instruction Manual and Warranty Information IM0034A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking
More informationSAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER
24 SAFETY AND OPERATING MANUAL Original instructions This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience
More informationAir-driven Universal Power Tool System for Traumatology, Endoprosthetics, and Spine. Compact Air Drive II. Instructions for Use
Air-driven Universal Power Tool System for Traumatology, Endoprosthetics, and Spine Compact Air Drive II Instructions for Use Contents Introduction General Information 2 Explanation of symbols used 4
More informationInstruction of use. Flexible Naso-Pharyngo- Laryngofiberscope,
Page 1 of 9 Legend 1 Ocular 2 Focussing ring 3 Working channel for flexible instruments 4 Bending protection 5 Deflectable, distal end 6 Lever for control of distal end 7 Fixation thread for pressure compensation
More information1 Pan - 6 Ways to Cook! Works in the Oven & On All Stovetops! electric gas ceramic induction. *only use. non-metal utensils
*only use non-metal utensils 1 Pan - 6 Ways to Cook! Broil Bake Sauté Fry Steam Braise Non-stick Cerami-Tech Ceramic Coating Even Heating Good for All Surfaces Easy Cleaning Durable, Stain Resistant Coating
More informationCLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A
CLEAN MIST ULTRASONIC HUMIDIFIER Instruction Manual and Warranty Information IM0040A READ AND SAVE THESE INSTRUCTIONS Contents Safety Instructions... 1 Unpacking / Specifications... 2 Parts & Contents...
More information