1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.
|
|
- Marshall Tyler
- 5 years ago
- Views:
Transcription
1 2018 NC Energy Conservation Code Commercial Mechanical Module 7 CHAPTER 5 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. a. ASHRAE Standard b. ASHRAE Standard c IECC d IECC 2. COMcheck software for ASHRAE may be used to demonstrate compliance for all of the following except. a. office building b. public school c. three story apartment building d. four story apartment building 3. The following are compliance path options for commercial buildings except. a. Chapter 4 [CE] mandatory and prescriptive provisions b. Section C407 Total Building Performance c. Section R406 Energy Rating Index Alternative d. COMcheck for ASHRAE Standard Chapter 4[CE] contains requirements for all the following except. a. industrial process systems and equipment b. HVAC systems for building space conditioning c. lighting controls d. service water heating 5. Using Table C (1), as of 1/1/2016, the minimum efficiency allowed for an electrically operated 120,000 Btu/h split system air cooled air conditioner with no electric resistance heat included is. a SEER b SEER c EER and 12.8 IEER d EER and 12.6 IEER 2018 NC Energy Conservation Code Page 1 of 9 Revised: 10/8/2018
2 6. Using Table C (4), the minimum efficiency allowed for a gas fired warm air furnace of 200,000 Btu/h input is. a. 78% AFUE b. 82% AFUE c. 90% AFUE d. 100% AFUE 7. The supply of heating and cooling energy to each building zone shall be controlled by an individual. a. humidistat b. occupancy sensor c. economizer d. thermostat 8. Exceptions from the requirements of automatic off-hour control of thermostats for zones of HVAC systems include all the following except. a. zones that will be operated continuously b. zones with a full load demand not exceeding 6,800 Btu/h and having a readily accessible manual shutoff switch c. HVAC systems serving residential units complying with C d. zones heated and cooled by packaged terminal heat pumps 9. For which case below would a required shut-off damper not be allowed to be a gravity damper? a. Ducted outside air intake of 300 cfm in a four-story building b. Ducted exhaust of 400 cfm in a two-story building c. Ducted outside air intake of 500 cfm in a single-story building d. Ducted exhaust of 200 cfm in a four-story building 10. Given that an exception is not applicable, demand control ventilation shall be provided for spaces larger than square feet and with an occupant load of 25 people or greater per 1,000 ft2 of floor area (as established in Table of the 2018 NC Mechanical Code). a. 250 b. 300 c. 400 d NC Energy Conservation Code Page 2 of 9 Revised: 10/8/2018
3 11. Given that an exception is not applicable, demand control ventilation is required for any HVAC system provided with outside air greater than cfm. a. 500 b. 1,000 c. 2,000 d. 3, Given that an exception is not applicable, an energy recovery system is required for commercial building ventilation systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of or greater of the design supply air quantity. a. 25% b. 50% c. 75% d. 85% 13. In commercial buildings, heating and cooling system supply and return ducts located in unconditioned space inside the building shall be insulated with a minimum of insulation. a. R-4 b. R-6 c. R-8 d. R In commercial buildings in Climate Zone 4, heating and cooling system supply and return ducts located outdoors shall be insulated with a minimum of insulation. a. R-4 b. R-5 c. R-8 d. R In commercial buildings in Climate Zone 3, heating and cooling system supply and return ducts located within a commercial building exterior wall that separates conditioned space from the outdoors shall be separated from the building exterior by a minimum of insulation. a. R-5 b. R-8 c. R-13 d. R NC Energy Conservation Code Page 3 of 9 Revised: 10/8/2018
4 16. In commercial buildings, heating and cooling system exhaust ducts located in conditioned space shall be insulated with a minimum of insulation or as otherwise required to prevent condensation formation on the duct exterior. a. R-0 b. R-4 c. R-5 d. R In commercial buildings, heating and cooling system supply ducts located within a return air plenum shall be insulated with a minimum of or as otherwise required to prevent condensation formation on the duct exterior. a. R-0 b. R-4 c. R-5 d. R In commercial buildings, the low-pressure heating and cooling ducts located in the following locations must be sealed except those located in. a. ventilated attics b. unconditioned spaces c. the conditioned spaces they serve d. ventilated crawl spaces 19. In commercial buildings, high pressure duct systems designed to operate in excess of 3 inches w.g. static pressure design pressure shall be leak-tested over representative sections totaling at least of the duct area. a. 25% b. 50% c. 75% d. 100% 20. Given that the designed chilled water temperature is 45 0 F, the required minimum piping insulation thickness for 2 inch nominal pipe diameter chilled water piping serving a chilled water plant for a building HVAC system is. a. no requirement b. 1 ½ inches c. 2 inches d. 3 inches 2018 NC Energy Conservation Code Page 4 of 9 Revised: 10/8/2018
5 21. Given that an exception is not applicable, test and balance activities for commercial building HVAC systems shall include. a. air system balancing only b. hydronic system balancing only c. both air system balancing and hydronic system balancing d. neither air system balancing nor hydronic system balancing 22. Given that a NC registered design professional s seal is required for a commercial building project, the required Statement of System Commissioning - Appendix C1 document is required to be prepared, signed, and submitted by the when system commissioning is required by Section C a. building owner b. contractor c. inspector d. NC registered design professional 23. Heating systems installed to provide comfort heating outside a commercial building shall be systems and require special controls to shut off the system when no occupants are present. a. convective b. radiant c. conductive d. None allowed 24. For a commercial building, neither an air side economizer nor a water side economizer is required for individual fan cooling units having a capacity less than Btu/h. a. 65,000 b. 75,000 c. 85,000 d. 98, Supply air economizers, when required for commercial building HVAC systems, shall be capable of providing outdoor air. a. 25% b. 50% c. 75% d. 100% 2018 NC Energy Conservation Code Page 5 of 9 Revised: 10/8/2018
6 26. In a commercial building in Climate Zone 4A, a required air economizer or water economizer can be exempted when the cooling equipment performance improvement above the minimum efficiency requirement is or greater. a. 20 per cent b. 27 per cent c. 42 per cent d. 49 per cent 27. Hydronic heating systems for commercial buildings comprised of a single boiler and greater than input design capacity shall include either a multi-staged or modulating burner. a. 200,000 Btu/h b. 300,000 Btu/h c. 400,000 Btu/h d. 500,000 Btu/h 28. For commercial buildings, hydronic heating systems greater than or equal to output capacity supplying heated water to comfort conditioning systems shall include part load controls having the capability to automatically reset supply hot water temperature or reduce system pump flow by at least 50% of the design flow rate. a. 200,000 Btu/h b. 300,000 Btu/h c. 500,000 Btu/h d. 1,000,000 Btu/h 29. For commercial buildings, generally, supply air systems serving multiple zones must be VAV systems and be provided with controls to reduce primary air supply to each space to a minimum before allowing any of the following to occur except for. a. reheating b. recooling c. recirculation d. mixing 30. For commercial buildings, multiple zone HVAC systems shall include controls that are capable of automatically resetting the supply air temperature to not less than of the difference between the design supply-air temperature and the design room temperature in response to representative building loads or outdoor air temperature NC Energy Conservation Code Page 6 of 9 Revised: 10/8/2018
7 a. 25% b. 50% c. 75% d. 100% 31. Condenser heat recovery shall be installed for heating or reheating of service hot water provided that the facility operates 24 hours a day, the total installed heat capacity of water-cooled systems exceeds 6,000,000 Btu/hr of heat rejection, and the design service water heating load exceeds. a. 250,000 Btu/h b. 500,000 Btu/h c. 750,000 Btu/h d. 1,000,000 Btu/h 32. For the prescriptive compliance option, a new commercial building must also comply with one of the Additional Prescriptive Compliance Requirements listed in Section C406. Which of the following is not one of the Additional Prescriptive Compliance Requirements listed? a. Increased insulation b. More efficient HVAC mechanical equipment c. Reduced lighting power density d. On-site renewable energy 33. For a commercial building, the Section C407 Total Building Performance compares the energy cost of the proposed design to that of the standard reference design. a. daily b. monthly c. annual d. lifetime 34. When the Section C407 Total Building Performance compliance approach is selected as the path to compliance for a commercial building, in addition to the required energy cost analysis, all of the following compliance documentation shall be provided to the inspector except. a. address of the residence b. an inspection checklist c. life cycle cost analysis d. name and version of the software 2018 NC Energy Conservation Code Page 7 of 9 Revised: 10/8/2018
8 2018 NC Energy Conservation Code Commercial Mechanical Module 7 CHAPTER 5 [CE] ANSWER KEY Number Answer Section 1. a C c C401.2, Chapter 2 Definition Commercial Building 3. c C a C403.1, C404.1, C c C , Table C (1) 6. a C , Table C (4) 7. d C d C a C , exceptions 1 and a C d EC c C b C c C b C a C a C c C , 2018 NC Mech Code Section Excep a C b C , Table C NC Energy Conservation Code Page 8 of 9 Revised: 10/8/2018
9 21. c C , C , C d C , C408.1, & Appendix C1 23. b C a C403.3, Exception d C c C403.3, Exception 7, Table C403.3(2) 27. d C b C c C a C d C a C c C c C NC Energy Conservation Code Page 9 of 9 Revised: 10/8/2018
1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.
2018 NC Energy Conservation Code Commercial Electrical Module 5 CHAPTER 4 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the
More information1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.
Energy Conservation Code Commercial Electric CHAPTER 5 WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is. a.
More information2009 IECC Commercial Mechanical Requirements
BUILDING ENERGY CODES UNIVERSITY 2009 IECC Commercial Mechanical Requirements Ken Baker PNNL-SA-66171 Learning(Objec-ves(( ( 1. Find(minimum(equipment(efficiency(requirements( and(recite(at(least(3(common(terms(for(measuring(
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 3.8.2 Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Rudy's Star Motors Construction Site:
More informationCOMcheck Software Version Review Mechanical Compliance Certificate
COMcheck Software Version 4.0.7.2 Review Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: Benton County Health Project
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.6.2 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2007) Standard HALCYON Bldg. 400 Alpharetta, Georgia 3a
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.4. Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 205 IECC Dallas, Texas 3a New Construction Construction Site: 56
More informationHVAC Mandatory Provisions Part II, Page 1
HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency
More informationSESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:
SESSION 1-2015 Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE (90.1.2013) ASHRAE Detroit Members: AM Session is eligible for (X) Professional Development
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 3.9.4 Mechanical Compliance Certificate 01 IECC Section 1: Information Type: Addition Title : Construction Site: Owner/Agent: Designer/Contractor: 3030 North Industrial Way Castle
More informationINDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS
A ADDITIONS AND ALTERATIONS Requirements........................ 101.4.3 ADMINISTRATION AND ENFORCEMENT..................... Chapter 1 AIR ECONOMIZERS Defined.................................202 Requirements........
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.3.0 Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: AHSC (Asian Heal Service Center
More informationApplication of the 2012 North Carolina Energy Conservation Code
Application of the 2012 North Carolina Energy Conservation Code Commercial Mechanical Presented By: NC Code Officials Qualification Board Office of State Fire Marshal NC Department of Insurance 2012 Modules
More informationCOMcheck Software Version Interior Lighting Compliance Certificate
Section 1: Project Information Energy Code: 2009 IECC Project Type: New Construction COMcheck Software Version 4.0.2.8 Interior Lighting Compliance Certificate Construction Site: Owner/Agent: Designer/Contractor:
More information2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
Mechanical Summary 2006 Washington State nresidential Energy Code Compliance Form MECH-SUM 2006 Washington State nresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address
More informationInspection Phase Three. Mechanical, Electrical & Plumbing Section 503
Inspection Phase Three Mechanical, Electrical & Plumbing Section 503 COMCheck Mechanical Field Inspection Checklist Mechanical Mechanical, Electrical & Plumbing Equipment Efficiencies But a lot ore too
More informationCOMcheck Software Version
COMcheck Software Version 4.0.4. Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 205 IECC Salt Lake City,Utah 5b New Construction Construction Site:
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Buda, Texas 2a New Construction Construction
More informationASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee
ASHRAE WILL GIVE YOU THE WORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee Complete the Distinguished Lecturer Event Summary Critique CTTC
More information2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC
2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC Mechanical Systems Agenda Changes in NREC Chapter 11 Changes in NREC Chapter
More informationMechanical Compliance Certificate
COMcheck Software Version 4.0.7.0 Mechanical Compliance Certificate Project Information Energy Code: Location: Climate Zone: Project Type: 90.1 (2013) Standard Austin, Texas 2a (weather data: TBD) New
More informationAugust 15, 2013 Page 1 of 19
Section C401 Application Compliance with C402, C403, C404 and C405 AND (either C406.2, C406.3 or C406.4) Compliance with C402, C403, C404 or C405 Section C402 Building Envelope (Climate Zone 5A) Space-Conditioning
More informationMassachusetts Energy Code Compliance Support Commercial Energy Code Building Mechanical & Service Water Heating Provisions
Massachusetts Energy Code Compliance Support 2015 Commercial Energy Code Building Mechanical & Service Water Heating Provisions Codes and Standards Initiative - Sponsors Your Instructor Stephen Turner
More informationCOMcheck Software Version Interior Lighting Compliance Certificate
Section 1: Project Information Energy Code: 2009 IECC Project Title: Berry Farms Animal Hospital Project Type: New Construction COMcheck Software Version 4.0.3.0 Interior Lighting Compliance Certificate
More informationHigh Performance Building Guide 1
Description This Guide is intended to be used for projects with a Vermont Certified: High Performance energy efficiency goal. This High Performance goal is a whole-building efficiency approach rather than
More information2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS
B 2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS COMMUNITY DEVELOPMENT DEPARTMENT 345 N. EL DORADO STREET STOCKTON, CA 95202 (209) 937-8561 www.stocktongov.com/cdd/building BUSINESS
More informationINTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings
INTRODUCTION TO: ASHRAE STANDARD 90.1, 2013 HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings Rocky Mountain ASHRAE Technical Conference, April 29, 2016 SEAN BEILMAN, P.E.,
More informationGil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee
Gil Rossmiller In the construction industry for over 30 years ICC IRC Plumbing & Mechanical Code Development Committee ICC- IECC Commercial Energy Code Development Committee Building Official Parker, Colorado
More informationASHRAE/IESNA Standard
ASHRAE/IESNA Standard 90.1-1999 An inside look at the requirements of Standard 90.1-1999 Energy Standard for Building Except Low-Rise Residential Building Mick Schwedler, PE Sr. Principal Applications
More informationONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*
ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION Project: Building Permit Application No.: DETAILED FORMS Location: Date: Architectural Designer Information* Mechanical Designer
More informationState of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney
Frenger Radiant chilled beam performance at 3D Model Creation Daylight Analysis Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled
More informationUNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More information2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems
2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems Dieter Bartel, Manitoba Hydro September 17 th, 2014 Outline Scope and compliance Prescriptive path
More informationFAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney
FAST AND ROBUST BUILDING SIMULATION SOFTWARE Chilled Beam Performance: 1 Shelly Street, Sydney 3D Model Creation 1 Shelley Street, Sydney 3D Model Creation 1 Shelley Street, Sydney Daylight Analysis 1
More information1 - This title will copy onto other forms Date
2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 Mechanical Summary MECH-SUM Project Title: 1 - This title will copy onto other forms Date 1/1/2015
More informationSECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL
SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division
More informationB. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.
PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the
More informationERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.
ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD 90.1-2013 (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings July 7, 2017 The corrections listed in this errata sheet apply to ANSI/ASHRAE/IES
More informationb.) Technical Information:
Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,
More informationCHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION
CHAPTER 23.20 LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION SECTIONS 23.20.100 Local Amendments To The International Mechanical Code, 2000 Edition 23.20.202 Definitions 23.20.301.14
More informationCOMMERCIAL ENERGY EFFICIENCY
CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL 501.1 Scope. The requirements contained in this chapter are applicable to commercial buildings, or portions of commercial buildings and to multiple-family
More informationThe Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma
Objectives and Requirements For the Creative and Performing Arts High School (CAPA), the main objective of the mechanical design is to provide an energy efficient system that is easily maintainable and
More informationHVAC Trajectories toward Zero
HVAC Trajectories toward Zero Jon McHugh, McHugh Energy at WCEC Affiliate Forum Western Cooling Efficiency Center Davis, CA May 7, 2013 jon@mchughenergy.com McHugh Energy Consultants CPUC Big Bold EE Strategies
More informationUPGRADES. [Energy Efficiency] Base Points
SmartRegs Prescriptive Pathway Property Address: Dates of Inspections and Updates: Inspector: Owner: Agent: 123 Boulder Initial Inspection Date: Update Date: 7/9/5 Scott Home Inspection Unit: Compliance
More informationC.E.P., C.E.M, C.I.P.E.
Subject What everyone needs to know about ASHRAE 90.1 J. Christopher Larry, P.E., C.E.P., C.E.M, C.I.P.E. Thursday, Joint ASHRAE AEE Meeting Cleveland, Ohio Introduction J. Christopher Larry P.E., C.E.P.,
More informationHVAC 101. The Basics of Heating, Ventilation and Air Conditioning
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning HVAC Heating, Ventilation and Air Conditioning Provides comfort for people Allows humans to exist under adverse conditions. Comfort Comfort
More informationMissouri HERO Program Residential Eligible Product List
All Products In addition to the HERO Product Eligibility Specifications listed below, it is the sole responsibility of the HERO Contractor and property owner (Project Stakeholders) to meet or exceed applicable
More informationPART 5: HVAC & DHW SYSTEMS
PART 5: HVAC & DHW SYSTEMS Building Science Review Building Science Review: HVAC & DHW Systems This document will help you: Correctly answer all parts of the HVAC Systems section in the Home Energy Score
More informationCOMMERCIAL ENERGY EFFICIENCY
CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY This chapter has been reformatted; some deletions are not marked. SECTION 501 GENERAL 501.1 Scope. The requirements contained in this chapter are applicable to commercial
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationChapter 7: Heating and Cooling Systems
[302.2.1] [302.1] Chapter 7: Heating and Cooling Systems Design Conditions The Washington State Energy Code sets the following conditions for heating system design and equipment sizing: Indoor Design Temperature:
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationTrane Engineers Newsletter Live
Trane Engineers Newsletter Live Presenters: John Murphy, Eric Sturm and Jeanne Harshaw (host) Trane program number: APP-CMC061-EN Agenda Trane Engineers Newsletter Live Series Abstract A large number of
More informationNAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency
NAHB Green Home Building Guidelines Energy Efficiency 3.1 Prerequisites 3.1.1 Home is equivalent to the IESS 2003 or local energy code. Conformance shall be based on plan analysis using software. 3.1.2
More informationwattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI)
Contractor-Certified HVAC Quality Assurance (HVAC-QI) HVAC Quality Assurance (HVAC-QI) Checklists The following checklists are required, with all applicable items completed and checked, including final
More informationBuilding Department Informational Handout
City of Sonoma Building Department Informational Handout Residential Water Heaters Handout No: 15 Revised: 4/26/18 A water heater is an appliance designed to supply hot water and is equipped with automatic
More informationInspection Checklist Mechanical Final
Property Owner Name: Property Address: Property Parcel Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans, and
More informationDehumidifying with Dedicated Outdoor Air
Dehumidifying with Dedicated Outdoor Air System Configurations Figure 71. Configurations for dedicated outdoor-air systems A dedicated outdoor-air handler separately filters, cools, dehumidifies, heats,
More information2018 International Energy Conservation Code (IECC) Updates
Providing effective energy strategies for buildings and communities 2018 International Energy Conservation Code (IECC) Updates 04.04.2018 12PM CDT Who we are Our goal: Reduce the energy footprint of Illinois.
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section
More informationSmall Building Program Design Phase Assistance
Small Building Program Design Phase Assistance Customer s Facility/Project Location XXXX/YYY, MA Project Team (if selected) Contact Firm Phone Email Customer: Electric PA: Gas PA: PAs s Technical Consultant:
More informationDesign Architect s/applicant s Certification Of Threshold Criteria
Design Architect s/applicant s Certification Of Threshold Criteria The Agency has requested certain certifications from the architect and applicant in connection with the submission of an application.
More informationEADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option
EADQUARTERS 707 N. Calvert St. Technical Report One ASHRAE Standard 62.1 Ventilation ASHRAE Standard 90.1 Energy Design Stephanie Kunkel www.engr.psu.edu/ae/thesis/portfolios/2011/slk5061 Mechanical Option
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationCity of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )
City of Chanhassen 7700 Market Blvd. - PO box 147 - Chanhassen, MN 55317 Phone 952-227-1180 - Fax 952-227-1190 - Web www.ci.chanhassen.mn.us Ventilation, Makeup and Combustion Air Calculations Instructions
More informationResidential New Home Construction Checklist
Residential New Home Construction Checklist A separate permit is required for each address. Address/PID: All materials and the installation of all materials must comply with the Minnesota State Building
More informationCITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA
CITY OF DANA POINT COMMUNITY DEVELOPMENT, BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248 3594 www.danapoint.org INDOOR AIR QUALITY B011 AIR 2013 CALIFORNIA CODES CODE
More informationAIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University
AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort
More informationDirect Install Program Eligible Measures Listing:
Direct Install Program Eligible Measures Listing: a) Lighting: - DLC qualified LED Luminaires including LED linear tube replacements - Energy Star Approved LED Screw In Lamps - T8 fixture replacements
More informationOSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon
OSU Alumni Center Phase I Implementation Review Prepared for Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon 97331 October 31, 2011 Job No. 02.11.00113 Introduction: Glumac was engaged by
More information2009 Washington State Energy Code Residential Sections
2009 Washington State Energy Code Residential Sections Gary Nordeen, Luke Howard, Emily Salzberg (360) 956-2042 energycode@energy.wsu.edu Produced with funding from: 1 WSEC text Washington State University
More informationIntermediate framed denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation.
CITY OF PORT ORCHARD Permit Center Office located at 720 Prospect Street Mailing address: 216 Prospect Street Pt Orchard, WA 98366 (360) 874-5533 permitcenter@cityofptchard.us RESIDENTIAL ENERGY CODE WORKSHEET
More informationRESNET HERS Rater Sample Test Questions 2
RESNET HERS Rater Sample Test Questions 2 1. Which of the following is the best device for removing standing water from a crawl space? A. Dehumidifier B. Sump pump C. Air-to-air heat exchanger D. Crawl-space
More informationSummary Comparison of Simulation Program Features
Summary Comparison of Simulation Program Features FEATURE DOE2.2 equest TRACE 700 HAP Public/Proprietary Public Domain Proprietary Proprietary Proprietary Simulation Method 8760 hours 8760 hours 8760 hours
More informationSite address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation
City of Victoria Building Inspections Department 7951 Rose Street P. O. Box 36 Victoria, MN 55386 (952) 443-4210 Ventilation, Makeup and Combustion Air Calculations Instructions and Example These instructions
More informationEnergy Upgrade California Home Upgrade Offered by The Energy Network
Energy Upgrade California Home Upgrade Offered by The Energy Network Who is The Energy Network? Local government organization Created by the California Public Utilities Commission Provides resources and
More informationEnergy Management and Controls
As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try
More information101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)
City of York Qdot Engineering 101 S. George St 116 E Gas Ave York, PA 17405 York, PA 17405 (717) 849-2329 (717) 744-8315 INSPECTION CHECKLIST Residential Mechanical 2009 Codes This checklist is intended
More informationJob Name Control Systems Description Date
Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In
More informationBOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationENERGY STAR Qualified Homes
ENERGY STAR Qualified Homes HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST 1 For Version 3 Part 2 of HVAC Quality Installation PRESENTED BY: Rocky Mountain Power wattsmart New Homes Program & Questar
More informationBuilding Division WSEC & IRC Ventilation (Effective July 1, 2016) Residential Buildings Prescriptive Compliance Form
Residential Please Energy & Submit IRC Ventilation two (2) Prescriptive copies Compliance Fm Effective 7-1-2016 (F hardcopy submittals: please submit 2 copies) Building Division 801 228 th Ave SE Sammamish,
More informationDesigning Energy Efficient Outdoor Air Systems
Designing Energy Efficient Outdoor Air Systems Joseph Thorndal Applied Products Sales Manager Greenheck, Schofield, Wisconsin 1 Joseph Thorndal BS Industrial Engineering North Dakota State University Work
More informationV4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)
V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY) ACN 114 572 084 "Driving Sustainability through Teamwork" e: pcthomas@teamcatalyst.com.au m: 0417 405 478 CALCULATING COOL USER GUIDE V4 15JUNE2016 Page
More informationREQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw
Residential Eligible Improvements and Guidelines FLORIDA To qualify for Ygrene funding, all project improvements must meet or exceed applicable local, state and federal codes and standards, and be installed
More informationREAD ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)
CALIFORNIA MECHANICAL CODE MATRIX ADOPTION TABLE APPENDIX E SUSTAINABLE PRACTICES (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority
More informationFlorida Department of Transportation
Page 1 of 7 RICK SCOTT GOVERNOR Florida Department of Transportation 1109 S. Marion Avenue Lake City, Florida 32025 ANANTH PRASAD SECRETARY September 27, 2011 To: Proposal Holders Addendum No: 1, E2Q23,
More informationLACLEDE ENERGY EFFICIENCY PROGRAMS
LACLEDE ENERGY EFFICIENCY PROGRAMS JUNE 10, 2015 S T. L O U I S G R E E N B U S I N E S S C H A L L E N G E WHAT I LL COVER TODAY Commercial/Industrial Rebate Program Building Operator Certification Residential
More informationPACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationNotable Changes in the Mechanical Codes
Notable Changes in the Mechanical Codes July 2004 The following are some of the changes between the 1997 Uniform Mechanical Code and the 2003 International Mechanical Code(M) and the 2003 International
More informationBOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationCOMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units
COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units Technical Development Program Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection
More informationAddress Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances
Rebate not to exceed cost of high efficiency equipment. Equipment must be purchased or recycled in 2015. Installed equipment must be on cooperative's lines. Submit the documentation listed below no later
More informationENERGY SYSTEMS LABORATORY
ESL-TR-8-11-2 RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES ON IMPLEMENTING HOUSTON AMENDMENTS TO SINGLE-FAMILY BUILDINGS IN HOUSTON TEXAS Zi Liu, Ph.D. Jaya Mukhopadhyay Mini Malhotra
More informationENERGY STAR v3.0 HVAC Checklists
IMPROVING THE BUILT ENVIRONMENT ENERGY STAR v3.0 HVAC Checklists Hands on Practice, Tips, and Lessons Learned Srikanth Puttagunta, P.E. Certified RESNET HERS Rater and Quality Assurance Designee Steven
More informationVentilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings
Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings Site Address Contractor Contractor Email Contractor Phone Date SECTION A Square feet * Number of bedrooms Ventilation Quantity
More informationINTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012
HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O INTRODUCTION HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationEquipment Specifications and Required Information Quantity Rebate
Rebate not to exceed 50% of the cost of equipment. Recycling rebates qualify for the entire rebate, regardless of the recycling cost. Equipment must be purchased or recycled in 2016. Installed equipment
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationPerformance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment
AHRI Standard 1230 with Addendum 1 2014 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment AHRI STANDARD 1230-2014 WITH ADDENDUM 1,
More information