Centeral Station Air Handling Unit
|
|
- Coral Lindsey Pearson
- 5 years ago
- Views:
Transcription
1 Centeral Station Air Handling Unit CA Series
2 The product range includes double skinned Air Handling Units, double skinned Fan Coil Units, and custom designed packaged roof top Air Conditioning Units. BASIS OF SELECTION OF DOUBLE SKINNED AIR HANDLING UNITS - CA SERIES MODEL NOMINAL AIR VOLUME FAN DIA / OUTLET COIL FACE WIBD cfm m 3 / hr L / sec mm m 2 m ,165 2, / ,757 3, / ,647 4,5000 1, / ,822 6,500 1, / , , / ,185 10,5000 2, / ,645 13,000 3, / ,400 16,000 4, / ,750 20,000 5, / ,530 23,000 6, / ,455 28,000 7, / ,600 35,000 9, / ,530 40,000 11, / ,415 50,000 13, / , , / ,170 70,000 19, / ,050 80,000 22, / Detailed fan and coil selections available on request. Non standard - custom designed and built Air Handling Units is WINS`S specialty
3 Model CA Air Handling Units are designed to give effective treatment of the air and are manufactured incorporating corrosion resistant materials, such as anodised profiles and stainless steel fixings. 1) CASING: Double skinned panels are fixed to an anodized aluminum alloy framework with stainless steel screws, forming a rigid casing enclosing the various air treatment sections such as mixing, filtration, heating, cooling, humidification, supply fan, extract fan. If required, various other sections such as heat recovery, multizone, sound attenuators can be incorporated. Air tight sealing is ensured through a neoprene gasket between the panel and the frame. Depending on the application and the operating environment, there are several options while selecting the composition of the double skinned panels. TYPE CA : Panels are of double skinned construction with insulation between two solid metal sheets. PANEL THICKNESS: 25mm or 50mm. PANEL MATERIALS: INNER SHEET (SOLID) Galvanized steel (plain/prepainted/preplasticised) Peraluman (Al. Alloy) Stainless Steel Sheet Galvanized Steel OUTER SHEET (SOLID) Galvanized steel (plain/prepainted/preplasticised) Peraluman (Al. Alloy) Stainless Steel Sheet Galvanized Steel PANEL INSULATION: MATERIAL DENSITY THERMAL CONDUCTIVITY kg/m 3 watt/m C Pressure injected foam Mineral Wool ACCOUSTIC PROPERTIES OF CA PANELS OF 25 MM THICKNESS: FREQUENCY K 2K 4K Sound Transmission Loss db (STC: 31) Sound Absorption Coefficient (NRC:0) ACCOUSTIC PROPERTIES OF CA PANELS OF 50 MM THICKNESS: FREQUENCY K 2K 4K Sound Transmission Loss db (STC: 35) Sound Absorption Coefficient (NRC:0) OPTIONAL: Casing type CA constructed with special sealing to meet high pressure Class C leakage rate when tested in accordance with DW/
4 Type CAP: Panels are of double skinned construction with insulation between two 1.0 mm thick metal sheets. The inner sheet is perforated while the outer sheet is solid. PANEL THICKNESS: 25mm or 50mm. ACCOUSTIC PROPERTIES OF CAP PANELS OF 25 MM THICKNESS: FREQUENCY K 2K 4K Sound Transmission Loss db (STC: 27) Sound Absorption Coefficient (NRC: 0.65) ACCOUSTIC PROPERTIES OF CAP PANELS OF 50 MM THICKNESS: FREQUENCY K 2K 4K Sound Transmission Loss db (STC: 29) Sound Absorption Coefficient (NRC: 0.95) PANEL MATERIALS: INNER SHEET (PERFORATED) Galvanized steel (plain) Peraluman (Al. Alloy) Galvanized Steel OUTER SHEET (SOLID) Galvanized steel (prepainted/preplasticised) Peraluman (Al. Alloy) Galvanized Steel PANEL INSULATION: MATERIAL DENSITY THERMAL CONDUCTIVITY kg/m 3 watt/m C Mineral Wool RECOMMENDATION: In view of their sound absorption characteristics, type CAP panels are recommended for fan sections or where attenuation is required to minimize the noise transmission into the ductwork
5 2) CONSTRUCTION: a) ACCESS DOORS: For inspection or maintenance of the components in various sections such as filters, fans, motors, coils, etc., double skinned access doors are provided either fully removable or with hinges made of die cast aluminum. b) RETURN/INLET PLENUM: Return/inlet plenums with same construction as unit casing can be supplied with or without opposed blade, volume control damper. c) BASE FRAMES: Units are supplied with a heavy gauge galvanized base frame. This base frame extends under the complete unit if unit is supplied in one section or under each section if unit is supplied in split sections. Optional: Intake Louver d) FILTER SECTION: Filter Banks are designed for easy withdrawal and replacement of filters. Fully sealed filter frames are designed to accommodate various types of filters such as: e) MIXING BOX & DAMPERS: Mixing Boxes are of same construction as the unit casing and are available with two or three dampers arrangement with configuration to suit the plant room ductwork. Dampers are sized for 6.0 m/ sec velocity. Dampers are of opposed airfoil blade type. Airfoil blades are made of aluminum alloy extrusions and are assembled in aluminum alloy framework. Optional - Panel filters - Automatic filters - Bag filters - Absolute filters Filters of specified manufacturer Filter manometers Filter pressure switches - Activated carbon filters - Intertial sand filters - Oil bath filters - Electrostatic filters f) COIL SECTION: Cooling/heating coils are computer selected to obtain specified heat exchange capacities. Cooling coils are of chilled water or direct expansion type, while heating coils are of hot water or steam type. Coils are made of copper tubes, mechanically bonded to aluminum fins, assembled in heavy gauge galvanized frame work. Water and steam coils are complete with galvanized steel headers while DX coils are with copper headers and brass refrigerant distributor. All coils are leak tested under water at 30 bar. Coils are mounted within the coil section to facilitate easy withdrawal. Drain pan made of stainless steel sheets is provided under the cooling coil section with threaded drain outlet. Optional Copper headers for water coils Vinyl coated aluminum fins Copper fins HERESITE coate coils Electro-tinning of Cu/Cu coil after manufacture. Stainless steel coil frame Run aruond coils - 5 -
6 g) MOISTURE ELIMINATOR: If necessary, moisture eliminators can be fitted after the cooling coil / humidifier section to avoid carry over of moisture. Eliminator blades are made of polypropylene and are assembled within a heavy guage galvanized steel frame. Optional: Eliminator blades made of galvanized sleel / prepainted steel / stainless steel, with frames made of galvanized steel sheets. h) HUMIDIFYING SECTION: Following types of humidifiers are available; Airwasher complete with recirculating pump, water distribution pipework, spray nozzles, inlet strainer, drain pan with overflow and moisture eliminator. Wet deck complete with recirculating pump. Spray coils. Pan and electric resistance. Self generated steam package. Alternatively, blank sections can be supplied to incorporate steam distributor / injector with steam from an external source. i) FAN SECTION: DIDW centrifugal fans with forward curved or backward curved imellers are available with various outlet configurations. Fans and casings are made of corrosion resistant materials or given corrosion resistant finish. All fan wheels and pulleys are statically and dynamically balanced and keyed to the shaft. Fan shafts are made of high quality solid steel and are supported on pregreased sealed for life ball bearings. Fans are driven by TEFC motor located within the unit casing. Fan and motor are mounted on a common base frame with facility to allow easy belt tensioning. Fan & motor assembly is isolated from the unit casing by antivibration mounts and a flame retardant flexible connector on the fan discharge. Optional: Fan casing and impellers hot dip galvanized after manufacture. Inlet guide vanes. Axial fans with variable van control. Fans with anti spark features. Fan casing with drain plugs and inspection doors. Belt guards. Two speed, variable speed or any other special motor. j) HEATER BATTERIES: Electric heater batteries are supplied with sheathed electric resistance heating elements made of finned steel tubes assembled within a galvanized steel frame. Entire assembly is located within the casing of the heating section. EHaters can be supplied with various capacities / stages as required. Optional: Heating elements made of stainless steel / copper tubes. Overheat thermostat or other controls. Terminal block with internal prewiring. 3) OTHER APPLICATIONS: Units can be supplied incorporating the following sections; Face and Bypass. Multizone. Dual duct. Heat recovery. Non standard units can be designed to meet client's constraints and to operate at severe climatic environments. 4) ACCESSORIES: On request, units can be supplied with the following accessories; Weatherproof roof canopy. Inspection window. Bulkhead lights
7 - 7 -
8 - 8 -
9 - 9 -
10 - 10 -
11 Nomenclature Type W : Wall Split T : Cassette Split F : Floor Standing U : Universal Split D : Ducted Split H : Horiz. Cond. Unit V : Vert. Cond. Unit P : Roof Top Package L : Chilled Water FUC C : Air Handling Unit AHU K : Window Unit Series Nominal Capacity MB TU/Hx1000 BTU/H Cooling Only - C C A 018 C 1 A R E E: elect. heat optional N: no elect heat R: R-22 N: R-407 C D: R-410 A A: T1 Stand. Ambient B: T3 Hi Ambient Heat pump - H Electncal code : v/ 1ph/50hz v/ 1ph/60hz v/ 1ph/60hz v/ 3ph/50hz v/ 3ph/60hz 6 460v/ 3ph/60hz
12 P.O.Box Dallas, Texas USA Tel Fax info@windind.com
AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationDouble Skin Casing Air Handling Units
Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationAIR HANDLING UNITS. Revision AG 16-07
AIR HANDLING UNITS UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationAIR HANDLER SPECIFICATION
AIR HANDLER SPECIFICATION Air Handlers AH-1 through 5 The following air handlers will be supplied: AH-1 FX15-4842 Series 5700 CFM AH-2 FX15-4236 Series 3990 CFM AH-3 FX15-3633 Series 2570 CFM AH-4 FX15-3330
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More informationIf a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.
Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationBulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications
Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationEasdale International INFINITY
Easdale International INFINITY Air flow from 800 to 0.000 m 3 /h APPLIED SYSTEM AIR HANDLING UNITS AHU N : 0.0.502 Range: Easdale International www.eurovent-certification.com www.certiflash.com Engineered
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationAIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.
SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving
More informationGeneral Catalogue. FORM SSI - G.C (94)
FORM SSI - G.C (94) www.ssi.co.ir General Catalogue INDEX 09CDF 16DNS 16DES 16JBP 16JBP Air Cooled Condenser Air Cooled Condenser Absorption Chiller Double Effect Direct Fired Absorption Chiller Double
More informationA. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.
15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution
More informationMODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC
MODUAR AIR HANDING UNIT Models: FAC / FMC / FBC Contents Product Nomenclature... 2 Features... 4 Engineering Specifications... 13 Cooling Coil Performance Chart... 13 Heating Coil Performance Chart...
More information39G Air Handling Unit
39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01
More informationSECTION AIR HANDLING UNIT
SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationCert. n Air Conditioning Vulcan Pro Air Handling Units
Cert. n 0545 Air Conditioning Air Handling Units The calculation program for these units, developed for heating contractors and designers, is included on the SABIANA CD-ROM. The CD contains the entire
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationDouble Skin Air Handling Units
Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering
More informationAir Handling Units. Real HVACR people who understand your needs.
Air Handling Units Real HVACR people who understand your needs. Copyright HC Heat-Exchangers (PTY) Ltd. 1 Copyright HC Heat-Exchangers (PTY) Ltd. 2 About the HC AHU range HC Heat-Exchangers rich engineering
More informationTYPICAL CPA SPECIFICATIONS
TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.
More informationGUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS
S FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS VAYHAN AIR CONTROLS PVT. LTD. G-1, Park View Residency, Patwari Enclave Gandhi Nagar (IDPL), Hyderabad 500 037. INDIA Phone: +91-40-2372
More informationAIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters
237300 AIR HANDLING PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230530 Clean Steam Generation B. Section 230900 Building Automation and Control System Guidelines C. Section 234100 Air Cleaning Devices
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15856 MODULAR AIR HANDLING UNITS PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. NFPA Compliance: Modular air handling units and components shall be designed, fabricated, and installed in compliance
More informationModular Air Handling Unit
MAHUs are modular so that they have the flexibility to add components as required. The 3rd generation Midea MAHU adapts unitary structure design, more outstanding cold-bridge free performance, lower air
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationSECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.
SECTION 15855 AIR HANDLING UNITS WITH COILS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Central Station Air Handling Units. B. Related Sections: 1.02 REFERENCES 1. Section 15010 - Basic Mechanical
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More informationCLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS
7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More informationDUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES
DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators
More informationCOOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS
COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS THE DAWN OF A NEW ERA Political and ecological pressures over the past few years, have led to a change of emphasis in the design of fully air-conditioned
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013
SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationDUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C
DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure
More informationRosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS
10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals
More informationYMA Custom Air Handling Units
airside products YMA Custom Air Handling Units by johnson controls Air Volume Range 0.25 m 3 /s to 60 m 3 /s YMA Custom Air Handling Units Air Volume Range 0.25 m 3 /s to 60 m 3 /s The YMA family of air
More informationModular Heating & Ventilating Unit Model IGX-HV
Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit
More informationAir Handling Units. T F E.
Air Handling Units Extract from BS EN ISO 15138:2007 Petroleum & natural gas industries- Offshore production installations-heating, ventilation & air-conditioning. A.12.1 Function Installations provided
More informationENGINEERING & SERVICE
CUSTOM AIR HANDLERS ENGINEERING & SERVICE Alliance Air Products has brought together an engineering team focused on practical solutions to all aspects of air handling unit design. Our engineers are leaders
More informationCLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements
Excellent quality / price ratio Very short delivery time Double wall 50 mm insulation Complete range meeting all the tertiary requirements Air flow : 000 to 7 000 m 3 /h DESCRIPTION Casing Double wall
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationINTRODUCTION.3 PRODUCT SPECIFICATIONS. 3
GENERAL CATALOGUE FIRST IN MIDDLE EAST QUALITY MAKE US THE BEST 1 CAT-GEN-2010 (1) INTRODUCTION.3 PRODUCT SPECIFICATIONS. 3 FAN COILS..4 FAN COIL CONDITIONERS. 4 TOP DISCHARGE EXPOSED FLOOR MODELS. 5 FRONT
More informationIndoor Air Quality. For assured. Double Skin Air Handling Units
Double Skin Air Handling Units INTL-31-OCT 06-R0 CI680512 For assured Indoor Air Quality. For more information, please contact BLUE STAR LIMITED, International Division, Band Box House, 4th Floor, Dr.
More informationSeries 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units
INTRODUCTION For more than 100 years, DunhamBush has focused on innovative product development. Today, we provide a full portfolio of HVAC/R products from Fan Coil Units to large centrifugal chillers as
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationALL PRODUCTS BROCHURE
ALL PRODUCTS BROCHURE www.aaon.com d e d i c at i o n t o cust o m e r service since the founding of aaon in 1988, we have maintained our commitment to design, develop, manufacture and deliver heating
More informationHood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL
The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationThe ultimate in air handling units: directly and indirectly fired
AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationA. Codes and Standards that are Standard at the University:
PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The
More informationPlenum Fans. Model HPA. Direct Drive
Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in
More informationCeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A
A e r o S y s I n c o r p o r a t e d Ceiling Mounted Systems CeilMate TM Series 3 and 4 tons of cooling capacity Air Handler with Remote Condensing Unit Air Handler designed for R-410A AeroSys, Inc. 929
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationAIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.
AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD. th No- A44/a 24, 6 Street, A Block,Anna Nagar East, Chennai-600102, Tamil Nadu, india +91 44 26208566 marketingindia@awalgulf.com,
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationWE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL
PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT
More informationYMA Air Handling Units
YMA Air Handling Units Certifications Page 2 Page 3 YMA Modular Air Handling Units Air Volume Range 0.25 m 3 /s to 26 m 3 /s The YMA family of air handling units has air volumes ranging from 0.25 m 3 /s
More informationAir Handling Units. direct drive - belt drive - custom built
for fresher air Air Handling Units direct drive - belt drive - custom built Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation Association;
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationVERTICAL FAN COIL UNITS
VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote
More informationSAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts
Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products
More informationSECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Specification Sections, apply to this Section. B. Related
More information39FD, FX. Air Handling Units. 280 l/s to l/s 39FD, FX
Air Handling Units 39FD, FX 220-7100 Quality Management System Approval 39FD, FX 280 l/s to 27000 l/s The comprehensive range of Carrier 39F air handling units is the result of detailed research in the
More informationCHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS
550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationHIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%
Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and
More informationVTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...
. - B 97 Product Detail... B98 Benefits... B100 Construction Details... B102 Custom Features and Options... B103 Accessories... B Engineering Data... B107 Structural Support... B111 Engineering Specifications...
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationMLR SERIES MODULAR AIR HANDLING UNITS
MODULAR AIR HANDLING UNITS General Information MAINSTREAM About Mainstream Mainstream offers a diverse line of custom air handling units, as well as heat transfer coils and other components required for
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationThe ultimate in air handling units: directly and indirectly fired
KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake
More informationRSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs
Lesson 1 - Basic Heat Pump Theory (Part 1) Describe the basic operation of a heat pump. Explain the function of various heat pump controls. Interpret the wiring diagrams and performance data provided by
More informationDirect Gas-Fired Make-Up Air
Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationFULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY
C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial
More informationStanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT
SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,
More informationHi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE
Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationUniversity of Delaware
University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 73 00_AIR HANDLING UNITS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular custom & semi-custom built indoor air handling
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationDirect Gas-Fired Make-Up Air Models DG and DGX
Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5
More information