Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

Size: px
Start display at page:

Download "Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace"

Transcription

1 Product Data Upflow/ Horizontal Left/Right, Single and Stage Non-Condensing Gas Fired Furnace Upflow,, Horizontal Right/Left Single Stage S8XA06MPSAA S8XA00MPSAA S8XB00MPSAA S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA Two Stage S8XA00MPSAA S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA Note:Modelsmayhavea T inthethdigitdesignatingtheymeet California less than 0 ng/j(nox) emissions requirements. S8X S8X Note:Graphics in this document are for representation only. Actual model may differ in appearance. October 08-6-A-EN

2 General Features NATURALGAS MODELS Central Heating furnace designs are certified by Intertek for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge tubular aluminized steel heat exchangerquickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and provide a discharge of gas fumes to the outside. BURNERS Multiport, Inshot burners will give years of quiet and efficient service. All models can be converted to L.P.gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. ENERGY EFFICIENT OPERATION Air-Tite cabinet design is certified to <% air leakage per ASHRAE 9 Method of Test for Determining the Airtightness of HVAC Equipment. AIR DELIVERY The 9 speed constant torque blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. STING Heavygauge steeland "wrap-around"cabinet constructionis used inthe cabinetwith bakedon enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES ANDGENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. -6-A-EN

3 Features and Benefits 80% AFUE on S8Xand S8XFURNACE MODELS Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use INCH TALL Lighter, easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts WAY MULTI-POISE S8X 9SKU s Upflow / /Horizontal Left / HorizontalRight S8X 7SKU s Upflow / /Horizontal Left / HorizontalRight Added application flexibility and reduction in specification errors AIRFLOW Atleast00 CFM/tonat0.in. H 0externalstatic pressure REGULATORY All modelsare air tight;%orless air leakage asper ASHRAE 9 Open vestibule design provides a full high open vestibule for ease of installation and service DIMENSIONS Widths are industry standard:., 7.,, and. Depth remains approximately 8 Cabinet is compatible with industry standard coils, as well as, other accessories INTEGRATED FURNACE CONTROL Setup / Status/ Diagnostics/ Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR ALUMINIZED STEELHEAT EXCHANGER VORTICA IIBLOWER,DESIGNEDEXCLUSIVELY FOR THE S-SERIESFURNACE Improved airflow efficiency Durable, easy to clean, housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise FOUR WAYMULTI-POISE (UPFLOW,DOWNFLOW,HORIZONTALLEFT AND RIGHT) Easier to specify Shipped ready to install(no conversion kits required) Every model has at least two venting options -6-A-EN

4 Accessories. Accessories Model Number Description Use with BAYHANG Horizontal Hanging Kit All Furnaces BAIFTB Dual Return Kit (B size extension) B Cabinet Furnaces BAIFTC Dual Return Kit (C size extension) C Cabinet Furnaces BAIFTD Dual Return Kit (D size extension) D Cabinet Furnaces BAYBASE0 Subbase All Furnaces in orientation BAYFLTR06 Filter Access Door Kit ( only) All Furnaces in orientation BAYSF6AA (a) SlimFit Box with MERV Filter All Furnaces BAYFLTR0 Horizontal Filter Kit B Cabinet Furnaces in /Horizontal BAYFLTR0 Horizontal Filter Kit C Cabinet Furnaces in /Horizontal BAYFLTR0 Horizontal Filter Kit D Cabinet Furnaces in /Horizontal BAYVENT600A Internal venting kit B, C, and D Furnaces in orientation BAYVENT800B Masonry Chimney Vent Kit All furnaces BAYSWTAHALTA High Altitude Pressure Switch Kit S8XA06MPSAA BAYSWTAHALTA High Altitude Pressure Switch Kit S8XA00MPSAA, S8XB00MPSAA, S8XC080MPSAA, S8XC00MPSAA BAYSWTAHALTA High Altitude Pressure Switch Kit S8XB060MPSAA, S8XB060MPSAA, S8XB080MPSAA BAYSWT6AHALTA High Altitude Pressure Switch Kit S8XA00MPSAA. S8XC080MPSAA BAYSWT7AHALTA High Altitude Pressure Switch Kit S8XB060MPSAA, S8XB060MPSAA BAYSWT8AHALTA High Altitude Pressure Switch Kit S8XB080MPSAA BAYSWT9AHALTA High Altitude Pressure Switch Kit S8XC00MPSAA BAPSS00B Propane Conversion Kit with Stainless Steel All Furnaces except S8XA06 Burners BAPSS0A Propane Conversion Kit with Stainless Steel S8XA06 Furnace only Burners PIP009 U fitting for gas piping All Furnaces for right hand gas entry (a) Airflow greater than 600 CFM requires dual returns -6-A-EN

5 Product Specifications MODEL S8XA06MPSAA S8XA00MPSAA S8XB00MPSAA TYPE RATINGS (a) Input BTUH 6,000 0,000 0,000 Capacity BTUH (ICS) (b) (c) 0,800,000,000 Temp. Rise (Min.-Max.) AFUE (%) BLOWER DRIVE DIRECT DIRECT DIRECT Diameter Width (In.) X 8 X 8 X 8 No. Used Speeds (No.) CFM vs. in. w.g. Motor HP / / / RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA COMBUSTION FAN Type Centrifugal Centrifugal Centrifugal Drive No. Speeds Direct - Direct - Direct - Motor HP RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA FILTER Furnished? No No No Type recommended High Velocity High Velocity High Velocity High Vel. (No.-Size-Thk.) x in. x in. 6x in. VENT PIPE DIAMETER Min (in.) (d) Round Round Round HEAT EXCHANGER Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge (Fired) ORIFICES Main Nat. Gas Qty. Drill Size GAS VALVE Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage PILOT SAFETY DEVICE Type 0 V SiNi Igniter 0 V SiNi Igniter 0 V SiNi Igniter BURNERS QTY POWER CONN. V/Ph/Hz (e) 0 / / 60 0 / / 60 0 / / 60 Ampacity (Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (in.) / / / DIMENSIONS Uncrated (In.) x. x 8.7 x. x 8.7 x 7. x 8.7 Crated (In.). x 6. x x 6. x x 9. x A-EN

6 Product Specifications MODEL S8XA06MPSAA S8XA00MPSAA S8XB00MPSAA WEIGHT Shipping (Lbs.) / Net (Lbs.) 0 / 9 0 / 9 8 / 0 (a) (b) (c) (d) (e) For U.S. applications, above input ratings (BTUH) are up to,000 feet, derate % per,000 feet for elevations above,000 feet above sea level. Central Furnace heating designs are certified to ANSI Z.7 / CSA. latest edition. Based on U.S. government standard tests. Refer to the Installer's Guide. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. MODEL S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA TYPE RATINGS (a) Input BTUH 60,000 60,000 80,000 Capacity BTUH (ICS) (b) (c) 8,000 8,000 6,000 Temp. Rise (Min.-Max.) AFUE (%) (c) BLOWER DRIVE DIRECT DIRECT DIRECT Diameter Width (In.) X 8 X 8 X 8 No. Used Speeds (No.) CFM vs. in. w.g. Motor HP / / / RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA COMBUSTION FAN Type Centrifugal Centrifugal Centrifugal Drive No. Speeds Direct - Direct - Direct - Motor HP RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA FILTER Furnished? No No No Type recommended High Velocity High Velocity High Velocity High Vel. (No.-Size-Thk.) 6x in. 6x in. 6x in. VENT PIPE DIAMETER Min (in.) (d) Round Round Round HEAT EXCHANGER Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge (Fired) ORIFICES Main Nat. Gas Qty. Drill Size GAS VALVE Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage PILOT SAFETY DEVICE Type 0 V SiNi Igniter 0 V SiNi Igniter 0 V SiNi Igniter BURNERS QTY POWER CONN. V/Ph/Hz (e) 0 / / 60 0 / / 60 0 / / 60 Ampacity (Amps) 0... Max. Overcurrent Protection (Amps) 6-6-A-EN

7 Product Specifications MODEL S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA PIPE CONN. SIZE (in.) / / / DIMENSIONS Uncrated (In.) x 7. x 8.7 x 7. x 8.7 x 7. x 8.7 Crated (In.). x 9. x x 9. x x 9. x 0.87 WEIGHT Shipping (Lbs.) / Net (Lbs.) 0 / / 7 / 9 (a) (b) (c) (d) (e) For U.S. applications, above input ratings (BTUH) are up to,000 feet, derate % per,000 feet for elevations above,000 feet above sea level. Central Furnace heating designs are certified to ANSI Z.7 / CSA. latest edition. Based on U.S. government standard tests. Refer to the Installer's Guide. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. MODEL S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA TYPE RATINGS (a) Input BTUH 80,000 00,000 0,000 Capacity BTUH (ICS) (b) (c) 6,000 80,000 96,000 Temp. Rise (Min.-Max.) AFUE (%) BLOWER DRIVE DIRECT DIRECT DIRECT Diameter Width (In.) X X X No. Used Speeds (No.) CFM vs. in. w.g. Motor HP RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA COMBUSTION FAN Type Centrifugal Centrifugal Centrifugal Drive No. Speeds Direct - Direct - Direct - Motor HP RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA FILTER Furnished? No No No Type recommended High Velocity High Velocity High Velocity High Vel. (No.-Size-Thk.) 0x in. 0x in. x in. VENT PIPE DIAMETER Min (in.) (d) Round Round Round HEAT EXCHANGER Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge (Fired) ORIFICES Main Nat. Gas Qty. Drill Size GAS VALVE Redundant - Single Stage Redundant - Single Stage Redundant - Single Stage PILOT SAFETY DEVICE Type 0 V SiNi Igniter 0 V SiNi Igniter 0 V SiNi Igniter -6-A-EN 7

8 Product Specifications MODEL S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA BURNERS QTY 6 POWER CONN. V/Ph/Hz (e) 0 / / 60 0 / / 60 0 / / 60 Ampacity (Amps)... Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (in.) / / / DIMENSIONS Uncrated (In.) x x 8.7 x x 8.7 x. x 8.7 Crated (In.). x x x x x 6. x 0.87 WEIGHT Shipping (Lbs.) / Net (Lbs.) / / 6 60 / (a) (b) (c) (d) (e) For U.S. applications, above input ratings (BTUH) are up to,000 feet, derate % per,000 feet for elevations above,000 feet above sea level. Central Furnace heating designs are certified to ANSI Z.7 / CSA. latest edition. Based on U.S. government standard tests. Refer to the Installer's Guide. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. MODEL S8XA00MPSAA S8XB060MPSAA S8XB060MPSAA TYPE RATINGS (a) st Stage Input BTUH 6,000 9,000 9,000 st Stage Capacity BTUH (ICS) 0,800,00,00 nd Stage Input BTUH 0,000 60,000 60,000 nd Stage Capacity BTUH (ICS) (b) (c),000 8,000 8,000 st Stage Temp. Rise (Min.-Max.) nd Stage Temp. Rise (Min.-Max.) AFUE (%) (c) BLOWER DRIVE DIRECT DIRECT DIRECT Diameter Width (In.) X 8 X 8 X 8 No. Used Speeds (No.) CFM vs. in. w.g. Motor HP / / / RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA COMBUSTION FAN Type Centrifugal Centrifugal Centrifugal Drive No. Speeds Direct - Direct - Direct - Motor HP RPM 00 / / / 600 Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 FLA FILTER Furnished? No No No Type recommended High Velocity High Velocity High Velocity High Vel. (No.-Size-Thk.) x in. 6x in. 6x in. VENT PIPE DIAMETER Min (in.) (d) Round Round Round HEAT EXCHANGER 8-6-A-EN

9 Product Specifications MODEL S8XA00MPSAA S8XB060MPSAA S8XB060MPSAA Type Aluminized Steel Aluminized Steel Aluminized Steel Gauge (Fired) ORIFICES Main Nat. Gas Qty. Drill Size GAS VALVE Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage PILOT SAFETY DEVICE TYPE 0 V SiNi Igniter 0 V SiNi Igniter 0 V SiNi Igniter BURNERS Qty POWER CONN. V/Ph/Hz (e) 0 / / 60 0 / / 60 0 / / 60 Ampacity (Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (in.) / / / DIMENSIONS Uncrated (In.) x. x 8.7 x 7. x 8.7 x 7. x 8.7 Crated (In.). x 6. x x 9. x x 9. x 0.87 WEIGHT Shipping (Lbs.) / Net (Lbs.) 0 / 9 0 / / (a) (b) (c) (d) (e) For U.S. applications, above input ratings (BTUH) are up to,000 feet, derate % per,000 feet for elevations above,000 feet above sea level. Central Furnace heating designs are certified to ANSI Z.7 / CSA. latest edition. Based on U.S. government standard tests. Refer to the Installer's Guide. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. MODEL S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA TYPE RATINGS (a) st Stage Input BTUH,000,000 6,000 8,000 st Stage Capacity BTUH (ICS),600,600,000 67,00 nd Stage Input BTUH 80,000 80,000 00,000 0,000 nd Stage Capacity BTUH (ICS) (b) (c) 6,000 6,000 80,000 96,000 st Stage Temp. Rise (Min.-Max.) nd Stage Temp. Rise (Min.-Max.) AFUE (%) (c) BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Diameter Width (In.) X 8 X X X No. Used Speeds (No.) CFM vs. in. w.g. Motor HP / RPM Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 0 / / 60 FLA COMBUSTION FAN Type Centrifugal Centrifugal Centrifugal Centrifugal Drive No. Speeds Direct - Direct - Direct - Direct - Motor HP RPM 00 / / / / 600 Volts/Ph/Hz 0 / / 60 0 / / 60 0 / / 60 0 / / 60 FLA A-EN 9

10 Product Specifications MODEL S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA FILTER Furnished? No No No No Type recommended High Velocity High Velocity High Velocity High Velocity High Vel. (No.-Size-Thk.) 6x in. 6x in. 0x in. x in. VENT PIPE DIAMETER Min (in.) (d) Round Round Round Round HEAT EXCHANGER Type Aluminized Steel Aluminized Steel Aluminized Steel Aluminized Steel Gauge (Fired) ORIFICES Main Nat. Gas Qty. Drill Size GAS VALVE Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage PILOT SAFETY DEVICE TYPE 0 V SiNi Igniter 0 V SiNi Igniter 0 V SiNi Igniter 0 V SiNi Igniter BURNERS (QTY) 6 POWER CONN. V/Ph/Hz (e) 0 / / 60 0 / / 60 0 / / 60 0 / / 60 Ampacity (Amps).... Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (in.) / / / / DIMENSIONS Uncrated (In.) x 7. x 8.7 x x 8.7 x x 8.7 x. x 8.7 Crated (In.). x 9. x x x x x x 6. x 0.87 WEIGHT Shipping (Lbs.) / Net (Lbs.) 7 / 9 / / 6 60 / (a) (b) (c) (d) (e) For U.S. applications, above input ratings (BTUH) are up to,000 feet, derate % per,000 feet for elevations above,000 feet above sea level. Central Furnace heating designs are certified to ANSI Z.7 / CSA. latest edition. Based on U.S. government standard tests. Refer to the Installer's Guide. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 0-6-A-EN

11 Airflow tables Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XA06MPSAA Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XA00MPSAA S8XA00MPSAA Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XB00MPSAA A-EN

12 Airflowtables Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XB060MPSAA S8XB060MPSAA Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XB060MPSAA S8XB060MPSAA Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XB080MPSAA S8XB080MPSAA A-EN

13 Airflow tables Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XC080MPSAA S8XC080MPSAA Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XC00MPSAA S8XC00MPSAA Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap S8XD0MPSAA S8XD0MPSAA A-EN

14 CFM Versus Temperature Rise S8X Furnaces have one stage heating S8X Furnaces have two stage heating. First Stage is Low heating and Second Stage is High heating.. S8X CFM Versus Temperature Rise Model S8XA06MPSAA 8 9 S8XA00MPSAA S8XB00MPSAA S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA S8X Low Heat CFM Versus Temperature Rise First Stage (Low) Heating Model S8XA00MPSAA S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA S8X High Heat CFM Versus Temperature Rise Second Stage (High) Heating Model S8XA00MPSAA S8XB060MPSAA S8XB060MPSAA S8XB080MPSAA S8XC080MPSAA S8XC00MPSAA S8XD0MPSAA A-EN

15 Wiring Diagrams NOTES:. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 0ºC. WIRES, 8, 9, 0, & ARE RATED 0 C.. FOR PROPER AIRFLOW IN COOLING/HEAT PUMP MODE, "Y" MUST BE CONNECTED TO THE THERMOSTAT FOR SINGLE STAGE UNITS. FOR TWO STAGE UNITS, "Y" AND "Y" MUST BE CONNECTED TO THE THERMOSTAT.. SINGLE STAGE SYSTEMS USE "Y" FOR THE CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK.. THE INDOOR BLOWER MOTOR AIRFLOW TABLES ARE LOCATED IN THE SERVICE FACTS. TO CHANGE AIRFLOW USE THE MENU/OPTIONS BUTTONS.. LINE CHOKE AND WIRE /8 ONLY USED ON MODELS WITH / AND HP MOTORS. 6. FLAME SENSE TEST PADS: VDC = MICROAMP. FLAME CURRENT CAN VARY DEPENDING ON THE VOM THAT IS USED AND THE VOLTAGE SUPPLIED TO THE FURNACE. THE ACCEPTABLE RANGE IS 0.7- MICROAMPS. BURNER BOX GR/8 MV RD/9 BL/ GAS VALVE MVC SEE NOTE 6 / RD/9 RD/6 BL/ / OR/ BL/ FLAME_PROBE / BLACK GR GREEN ITE BR BROWN YELLOW RD RED OR ORANGE BL BLUE IGN HOT SURFACE IGNITER RAF REVERSE AIR FLOW PS PRESSURE SWITCH BL/ RD/ v LINE CHOKE /7 / TNS LINE V LINE V PS OR/ 0v /8 /7 FP HLI MV TH MVC HLO PS TR ILI (NOT USED) IFC } } / / SEE NOTE / FACTORY WIRING FIELD WIRING / / /6 EAC HUM LINE NEUTRAL / 0 VAC MAY BE USED FP FUSE AMP LC LINE CHOKE GROUND MENU TNS-H CIRC-H LINE-H Stage Inducer with CTM Blower Motor Status Codes dl Idle HOd Heat Off Delay (sec) Ht tp Heating Blower Tap Number COF COp COF Continuous Fan CP st Stage Cooling/ st Stage Heat Pump CP nd Stage Cooling/ nd Stage Heat Pump Htp run dft Defrost Mode Menu Options Err Active Alarm Menu L6 F Last 6 Faults (To Clear, E0 E. Hold Option Button sec) E. Cr Code Release Number COd Cooling Off Delay (sec) E. ODU Outdoor Unit OPTION LINE-N (blocked) CIRC-N TNS-N IGN-N IND-N IND-H IGN-H TAP TAP TAP TAP TAP W R G B/C Y/Y Y THERMOSTAT SEE NOTES AND Blower Tap for Continuous Fan C. Blower Tap for st Stage Compressor Mode C. Blower Tap for nd Stage Compressor Mode H. Blower Tap for Heating Mode Run Test Mode Error Codes Loss of the IRQ/other internal failures Retry exceeded (Failed to est flame) Recycles exceeded (loss of established flame) 0X or PS open Gas Valve not energized when it should be exceeded after 0 times / / /0 /9 BL/ /6 / /6 /8 BL/7 /7 /7 /6 RAF- RAF- / /0 /8 / RD// // BL// //6 OR//6 BL/7 TO BURNER BOX HARN / / RD// /9 /0 /8 / FRS FLAME ROLLOUT SWITCH FP FLAME PROBE ** INTERNAL THERMAL PROTECTION E. E. E0 E0 E6. E6. E6. E7. E08 E E H N HLO HLI PS IND IFC RAF TH TR MVC MV TNS ILI IGN FP RD// // BL// //6 OR//6 LINE NEUTRAL GROUND HIGH LIMIT OUTPUT HIGH LIMIT INPUT PRESSURE INPUT INDUCER INTEGRATED FURNACE CONTROL REVERSE AIRFLOW VAC (HOT) VAC (COMMON) VALVE COMMON MAIN VALVE TRANSFORMER INDUCER LIMIT INPUT IGNITER FLAME PROBE L G N /0 /0 /9 //6 BL//7 //8 OR// 0v 60 Hz. PH POWER SUPPLY PER LOCAL CODE IFC IS POLARITY SENSITIVE JUNCTION BOX H N /0 FLAME_ROLLOUT FLAME_ROLLOUT THERMAL_LIMIT BLOWER MOTOR / / GR// PANEL LOOP COM 6 GR// / /9 IGN S8X /8 / / BL/ /9 VENT MOTOR (INDUCER) ** ELECTRICAL RATING INPUT: VAC, 60 HZ XFMR SEC. CURRENT: 0MA. + MV LOAD MV VAC IND OUTPUT:. FLA,. VAC IGN OUTPUT:.0 0 VAC CIRC. BLOWER OUTPUT:. FLA, 0 VAC HUMIDIFIER & AIR CLEANER (DRY CONTACTS) MAX. 0VAC VAC OR 0 VAC MAY BE USED FUSE: A Shorted Pressure Switch Open Pressure Switch Open Thermal Limit, Rollout Switch, or Reverse Airflow Switch Flame detected, should not be present Voltage reversed polarity Bad Grounding () Igniter relay fails () Igniter open Gas valve is energized when it should be off Flame current is low, but still strong enough to allow operation () Gas valve not energized () Gas valve relay stuck closed Open fuse /7 INTEGRATED FURNACE CONTROL TIMINGS PREPURGE: 0 SEC. INTERPURGE: 60 SEC. POST PURGE: SEC. IGN WARMUP: 0 SEC. IAP: ; TFI: SEC. RETRIES: RECYCLES: 0 HEAT ON DELAY: UP TO 0 SEC. COOL ON DELAY: 0 SEC. AUTO RESTART: 60 MIN. AUTO RESTART PURGE: 60 SEC. D8P0 IFC 0v 60 Hz. PH POWER SUPPLY PER LOCAL CODE JUNCTION BOX GR/ ILI TR PS HLO MVC TH HLI MV FP W R G B/C Y/Y FLAME_ROLLOUT THERMOSTAT SEE NOTES AND RAF- FLAME_ROLLOUT LINE-H CIRC-H TNS-H TNS-N CIRC-N LINE-N IGN-H IND-H IND-N IGN-N TAP TAP TAP TAP TAP 6 GR/ Y RD/ / BL/ / OR/ BL BL OR BL RD GR RD H N THERMAL_LIMIT PS RAF- FLAME PROBE OR PANEL LOOP IGN VENT MOTOR (INDUCER) ** v TNS RD BL 0v S8X GR/ RD/ / BL/ / OR/ BL MV C N G L LINE CHOKE BLOWER MOTOR COM GAS VALVE SEE NOTE BURNER BOX -6-A-EN

16 Wiring Diagrams NOTES:. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THIS FURNACE MUST BE REPLACED, IT MUST BE WITH WIRE HAVING A TEMPERATURE RATING OF AT LEAST 0ºC. WIRES, 8, 0, & ARE RATED 0 C.. FOR PROPER AIRFLOW IN COOLING/HEAT PUMP MODE, "Y" MUST BE CONNECTED TO THE THERMOSTAT FOR SINGLE STAGE UNITS. FOR TWO STAGE UNITS, "Y" AND "Y" MUST BE CONNECTED TO THE THERMOSTAT.. FOR SINGLE STAGE THERMOSTATS, JUMPER "W" AND "W" TERMINALS. SECOND STAGE HEATING WILL BE ENERGIZED ONCE THE INTER-STAGE DELAY HAS EXPIRED. "HT" WILL BE SHOWN ON SEVEN SEGMENT DISPLAY AT ALL TIMES.. FOR HEAT PUMP SYSTEMS, "Y" AND "O" TERMINALS MUST BE CONNECTED TO THE ROOM THERMOSTAT. FOR TWO STAGE UNITS, "Y", "Y", AND "O" TERMINALS MUST ALL BE CONNECTED TO THE ROOM THERMOSTAT.. FOR TWO STAGE SYSTEMS, USE "Y" FOR LOW SPEED AND "Y" FOR HIGH SPEED CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK. SINGLE STAGE SYSTEMS USE "Y" FOR THE CONNECTION TO THE LOW-VOLTAGE TERMINAL BLOCK. 6. THE INDOOR BLOWER MOTOR AIRFLOW TABLES ARE LOCATED IN THE SERVICE FACTS. TO CHANGE AIRFLOW USE THE MENU/OPTIONS BUTTONS. 7. LINE CHOKE AND WIRE /8 ONLY USED ON MODELS WITH / AND HP MOTORS. 8. FLAME SENSE TEST PADS: VDC = MICROAMP. FLAME CURRENT CAN VARY DEPENDING ON THE VOM THAT IS USED AND THE VOLTAGE SUPPLIED TO THE FURNACE. THE ACCEPTABLE RANGE IS 0.7- MICROAMPS. / BR/ PS BR/7 GAS VALVE RD/9 BL/ BR/0 BL/ RD/6 LINE CHOKE v TNS /7 / 0v /8 PS OR/ / / SEE NOTE 7 / / RAF- /7 /6 RAF- /0 /9 BL/ /6 / /6 /8 BL/7 TO BURNER BOX HARN / / RD// /8 /9 /9 / RD// // BL// //6 OR//6 L G N /0 /0 /9 FLAME_ROLLOUT FLAME_ROLLOUT BLOWER MOTOR THERMAL_LIMIT COM //6 BL//7 //8 OR// GR// GR// /8 / / BL/ 0v 60 Hz. PH POWER SUPPLY PER LOCAL CODE IFC IS POLARITY SENSITIVE JUNCTION BOX H N 6 S8X /9 /7 IFC 0v 60 Hz. PH POWER SUPPLY PER LOCAL CODE JUNCTION BOX GR/ LINE-H CIRC-H TNS-H TNS-N CIRC-N LINE-N IGN-H IND-HI IND-LO IND-N IGN-N TAP TAP TAP TAP TAP 6 GR/ H RD RD/ / BL/ / OR/ BL N PANEL LOOP IGN VENT MOTOR (INDUCER) ** S8X GR/ RD/ / BL/ / OR/ BL N G L LINE CHOKE BLOWER MOTOR COM SEE NOTE 7 OR GR BR RD BL BURNER BOX GR/8 FLAME_PROBE BR/ BR/0 RD/9 BR/7 RD/6 BL/ / OR/ BL/ / LINE V LINE V SEE NOTE 8 FACTORY WIRING FIELD } WIRING /7 FP HLI MVH MVL PS TH MVC HLO PS TR ILI (NOT USED) IFC Stage Inducer with CTM Blower Motor dl Status Codes Idle sd CFP Ht st Stage Heating COP Ht nd Stage Heating tp Blower Tap Number COF Continuous Fan CL st Stage Cooling HtP CL nd Stage Cooling HP st Stage Heat Pump run HP nd Stage Heat Pump dft Err Defrost Mode Menu Options Active Alarm Menu E0 E. E. L6 F Last 6 Faults (To Clear, Cr COd OdU H0d BLACK ITE YELLOW ORANGE GREEN BROWN RED BLUE Hold Option Button sec) Code Release Number Cooling Off Delay (sec) Outdoor Unit Heat Off Delay (sec) } IGN HOT SURFACE IGNITER RAF REVERSE AIR FLOW E. E. E. E. / / TNS-H CIRC-H LINE-H / /6 EAC HUM LINE NEUTRAL / 0 VAC MAY BE USED FP AMP MENU OPTION LINE-N (blocked) CIRC-N TNS-N IGN-N IND-N IND-LO IND-HI IGN-H TAP TAP TAP TAP TAP W W R G B/C Y Y O THERMOSTAT SEE NOTES,,, PS PRESSURE SWITCH FUSE LC LINE CHOKE /7 ** INTERNAL THERMAL PROTECTION Inter-Stage Delay (sec) Blower Tap for Continuous Fan C. Blower Tap for st Stage Compressor Mode C. Blower Tap for nd Stage Compressor Mode H. Blower Tap for st Stage Heating H. Blower Tap for nd Stage Heating Run Test Mode Error Codes Loss of the IRQ/other internal failures Retry exceeded (Failed to est flame) Recycles exceeded (loss of established flame) or 0X PS open st Stage Gas Valve not energized when it should be exceeded after 0 times Shorted Pressure Switch, st Stage Open Pressure Switch, st Stage Shorted Pressure Switch, nd Stage / / /0 / RD/9 /8 / 6 E. E0 E0 E6. E6. E6. E7. E08 E09 E E RD// // BL// //6 OR//6 BL/7 FRS FLAME ROLLOUT SWITCH FP FLAME PROBE GROUND H N HLO HLI PS PS IND IFC RAF TH TR MVC MVL MVH TNS ILI IGN FP HI LO LINE NEUTRAL GROUND HIGH LIMIT OUTPUT HIGH LIMIT INPUT ST STAGE PRESSURE INPUT ND STAGE PRESSURE INPUT INDUCER INTEGRATED FURNACE CONTROL REVERSE AIR FLOW VAC (HOT) VAC (COMMON) VALVE COMMON VALVE LOW STAGE VALVE HIGH STAGE TRANSFORMER INDUCER LIMIT INPUT IGNITER FLAME PROBE SECOND STAGE FIRST STAGE /0 PANEL LOOP / /9 VENT MOTOR (INDUCER) ** IGN INTEGRATED FURNACE CONTROL ELECTRICAL RATING INPUT: VAC, 60 HZ. XFMR SEC. CURRENT: 0 MA. + MV LOAD MV VAC IND OUTPUT:. FLA,. 0 VAC IGN OUTPUT:.0 0 VAC CIRC. BLOWER OUTPUT:. FLA, 0 VAC AIR CLEANER (DRY CONTACTS) MAX. LOAD:.0 0 VAC VAC OR 0 VAC MAY BE USED FUSE: A TIMINGS PREPURGE: 0 SEC. INTERPURGE: 60 SEC. POST PURGE: SEC. IGN WARMUP: 0 SEC. IAP: ; TFI: SEC. RETRIES: RECYCLES: 0 HEAT ON DELAY: 0 SEC. COOL ON DELAY: 0 SEC. AUTO RESTART: 60 MIN. AUTO RESTART PURGE: 60 SEC. Open Pressure Switch, nd Stage Open Thermal Limit, Rollout Switch, or Reverse Airflow Switch Flame detected, should not be present Voltage reversed polarity Bad Grounding () Igniter relay fails () Igniter open st stage gas valve (MVL) is energized when it should be off Flame current is low, but still strong enough to allow operation. Open Inducer Limit Switch or Condensate Switch () st stage gas valve not energized when it should be () st stage gas valve relay stuck closed () nd stage gas valve relay stuck closed () nd stage gas valve energized when it should not be () nd stage gas valve not energized when it should be Open fuse D87P0 ILI TR PS HLO MVC TH PS MVL MVH HLI FP W W R G B/C Y Y O THERMOSTAT SEE NOTES,,, FLAME_ROLLOUT RAF- FLAME_ROLLOUT BL OR BL RD BR GR RD BR BR THERMAL_LIMIT PS RAF- FLAME PROBE OR v BR TNS RD BL BR 0v PS GAS VALVE BURNER BOX BR 6-6-A-EN

17 Electrical Connections Make wiring connections to the unit as indicated on enclosed wiring diagram. As with all gas appliances using electrical power, this furnace shall be connected into a permanently live electric circuit. It is recommended that furnace be provided with a separate "circuit protection device" electric circuit. The furnace must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. The integrated furnace control is polarity sensitive. The hot leg of the 0V power supply must be connected to the black power lead as indicated on the wiring diagram. Refer to the SERVICE FACTS literature and unit wiring diagram attached to furnace. Field Wiring Two Stage Thermostat W Furnace W HP FIELD WIRING DIAGRAM FOR S8X SINGLE STAGE HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP Outdoor Unit (No Transformer) X NOTES: ) HP = Wiring used for Heat Pump systems. ) Y and/or Y must connect from the thermostat to the IFC for proper airflow. ) A/TCONT8 thermostats do not require the use of X. R R HP R G G B B B Y Y Y Y Y Y O HP O Two Stage Thermostat W W R G B Y Y Furnace W W R G B Y Y HP HP FIELD WIRING DIAGRAM FOR S8X TWO STAGE HEATING THERMOSTAT, ONE / TWO STAGE AC OR HEAT PUMP Outdoor Unit (No Transformer) X R B Y Y NOTES: ) HP = Wiring used for Heat Pump systems. ) Y and/or Y must connect from the thermostat to the IFC for proper airflow. ) Remove Y - O jumper on IFC for HP systems. ) If the thermostat does not have W, or there are not enough conductors jumper W to W at the IFC. ) A/TCONT8 thermostats do not require the use of X. O HP O HP O -6-A-EN 7

18 Outline Drawings.. Width Cabinet 8-6-A-EN

19 OutlineDrawings Width Cabinet -6-A-EN 9

20 OutlineDrawings 7..0 Width Cabinet 0-6-A-EN

21 OutlineDrawings 8.. Width Cabinet -6-A-EN

22 Notes -6-A-EN

23 Notes -6-A-EN

24 Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. -6-A-EN Oct 08 Supersedes(New) 08 Ingersoll Rand

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Product Data Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace Upflow, Convertible to HorizontalRight or HorizontalLeft S9X2B040U2PSAA S9X2B040U3PSAA S9X2B060U3PSAA S9X2B060U4PSAA

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2C100U4PSBA Note:Graphics in this document are for

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG: Submittal Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH Downflow Only S9V2B080D3PSBA Note:Graphics in this document are for representation only. Actual model may differ in appearance. SAFETYWARNING

More information

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG: Submittal Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH Downflow Only S9V2B060D3PSBA Note:Graphics in this document are for representation only. Actual model may differ in appearance. SAFETYWARNING

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are

More information

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG: Submittal Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH Downflow Only S9V2C100D4PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,

More information

Downflow/Horizontal Right Induced Draft Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace Downflow/Horizontal Right Induced Draft Gas Furnace American Standard 80 ADE1A060A9361A, ADE1B060A9361A ADE1B080A951A, ADE1B100A951A ADE1C100A9601A, ADE1D120A9601A Single-Stage Fan Assisted Combustion

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner XV80i TUD2B060AFV32A, TUD2B080AFV32A, TUD2C080AFV42A, TUD2B100AFV32A, TUD2D120AFV52A 2009 Trane All Rights Reserved

More information

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace XR 80 TDDA00A92A, TDDA060A92A, TDDA060A936A, TDDB060A936A, TDDB080A936A, TDDB080A95A TDDB00A95A, TDDC00A98A, TDDC00A95A TDDCA95A,

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-10 General

More information

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX060, 080, 100, 120R TDX060, 080, 100, 120R Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-02-1202

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace TDD-D- XB 80 TUEA00A92A, TUEA060A92A, TUEA060A936A TUEB060A936A, TUEB080A936A, TUEB080A98A TUEB00A936A, TUEC00A98A, TUEC00A960A

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace Upflow/Horizontal Condensing, Gas-Fired Furnace TDD-D-1 90% Furnace AUC1B00A921A, AUC1B060A9361A AUC1B080A921A, AUC1C100A981A AUC1D100A9601A, AUC1D120A9601A Single-Stage Fan Assisted Combustion System

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TUDA00A92B, TUDA00A930B, TUDA060A92B, TUDA060A936B, TUDB060A936B, TUDB080A92B, TUDB080A936B, TUDB080A98B, TUDC080A960B,

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TDD-D- TUDA00A92A, TUDA00A930A, TUDA060A92A, TUDA060A936A, TUDB060A936A, TUDB080A92A, TUDB080A936A, TUDB080A98A, TUDC080A960A,

More information

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX2B060A9362A, TUX2B080A922A, TUX2C100A982A, TUX2D1A9602A, TDX2B060A9362A, TDX2B080A922A, TDX2C100A982A,

More information

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace Freedom 80 AUD2A00A922A, AUD2A060A9362A, AUD2B060A9362A, AUD2B080A9362A, AUD2B080A982A, AUD2B00A9362A, AUD2C00A982A, AUD2C00A9602A, AUD2D00A9602A,

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006 Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

40 Residential Gas Furnace Operation

40 Residential Gas Furnace Operation 40 Residential Gas Furnace Operation Model Evolution/Nomenclature Heating Sequence of Operation Schematics Ignition Systems Service/Troubleshooting American Standard Inc. 999 Preface Air Conditioning and

More information

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA SERVICE FACTS Gas Furnaces Upflow & Downflow Induced Draft Stage Heat Models: M80P00AU2AA M80P060AU2AA M80P060AU36AA M80P080BU36AA M80P080BU8AA M80P00BU36AA M80P00CU8AA M80P00CU60AA M80PDU60AA M80P0DU60AA

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models: Service Facts X349P0 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models: *UY060R9V3W *UY080R9V3W *UY00R9V4W *UY20R9V5W * First letter may be A or T *DY060R9V3W *DY080R9V3W

More information

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability. FURNACES The Ameristar line of heating and cooling products offer you flexible and affordable options for HVAC equipment replacement. The Ameristar product line should complement the national brand you

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 21M51U-843 Universal Integrated Two-Stage 120Volt Hot Surface Ignition Control Kit INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA UH2P-SF-1B Gas Furnace Direct Vent Condensing Two Stage Heat Models: * - First letter may be A or T *UH2B060A936VA *UH2B080A942VA *UH2C100A948VA *UH2D120A960VA *DH2B060A936VA *DH2B080A942VA *DH2C100A948VA

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

50A Integrated Furnace Control

50A Integrated Furnace Control 50A56-956 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY

More information

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA UD2-9V-SF-C Gas Furnace Speed 2 Stage Heat Models: * - First letter may be A or T *UD2B060A9V3VB *UD2B080A9V3VB *UD2C080A9V4VB *UD2C080B9V4VB *UD2B00A9V3VB *UD2C00A9V5VB *UD2C00B9V5VB *UD2DA9V5VB *UD2DB9V5VB

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-474 & 50A55-571 Integrated Furnace Controls INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE

More information

50A Integrated Furnace Control

50A Integrated Furnace Control Goodman White-Rodgers 0130F00005 PCBBF110 PCBBF123 50A55-743 0130F00005S PCBBF110S PCBBF123S 50A55-289 B1809926 PCBBF112 50T55-289 B1809926S PCBBF112S 50A55-743 Integrated Furnace Control INSTALLATION

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A65-843 Universal Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A66-743 Integrated Furnace Control Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SB TEM4A0B24S21SB TEM4A0B30S31SB TEM4A0B36S31SB TEM4A0C37S31SB TEM4A0C42S41SB TEM4A0C48S41SB TEM4A0C60S51SB The TEM4 series air handler is designed

More information

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION 50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS INSTALLER MUST READ PAGE 3 CONTAINS WIRING HARNESS AND BLOWER CONNECTION INSTRUCTIONS FOR ALL APPLICATIONS

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton Product Data Convertible Air Handlers 1 1/2 5Ton TEM4A0B18S21SA TEM4A0B24S21SA TEM4A0B30S31SA TEM4A0C36S41SA TEM4A0C42S41SA TEM4A0C48S41SA TEM4A0C60S51SA The TEM4 series air handler is designed for installation

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS 50M56-743 Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS 50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS INSTALLER MUST READ PAGE 3 CONTAINS WIRING HARNESS AND BLOWER CONNECTION INSTRUCTIONS FOR ALL APPLICATIONS

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

ELITE SERIES Downflow - High Efficiency Blower Motor

ELITE SERIES Downflow - High Efficiency Blower Motor PRODUCT SPECIFICATIONS GAS FURNACES EL80DFE ELITE SERIES Downflow - High Efficiency Blower Motor Bulletin No. 2066 July 208 Supersedes February 208 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0124 L11 Revised 11 2006 G60UHV(X) G60UHV(X) SERIES UNITS G60UHV(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. AMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0204 L2 Revised 09 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0211 L3 Revised 09 2006 G60DFV(X) G60DFV(X) SERIES UNITS G60DFV series units are mid efficiency gas furnaces used for downflow applications only, manufactured with Lennox Duralok

More information

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL MANUAL. GMH8 39 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal TECHNICAL MANUAL AL GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal Refer to Service Manual RS660004 for installation, operation, and troubleshooting information.

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Cooling Capacity CFM range

Cooling Capacity CFM range R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Cabinet air leakage less than 2.0% at 1.0 in. W.C. and

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) R9MSB Product Specifications 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning

More information

13 GEP A L P - 1 A

13 GEP A L P - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800

More information

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG: Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower P R O D U C T S P E C I F I C AT I O N S G A S F U R N A C E S SL280DFV DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Blower Bulletin No. 20576 December 200 Supersedes July 200

More information

GKS9 40" 90% Gas Furnaces

GKS9 40 90% Gas Furnaces TECHNICAL MANUAL AL 40" 90% Gas Furnaces Refer to Service Manual RS6610004* for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL

More information

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS 21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE

More information

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM 21M51U-843 WIIN AND CONFIUATION INTEATED HOT (LINE) TYPICAL WIIN DIAAM 120 VAC NEUTAL (LINE) 24 VAC CLASS II TANSFOME TH 24 VAC T COOL PAK HEAT LO HEAT HI LINE XFM EAC HUM CICU- LATO BLOWE HUMIDIFIE (OPTIONAL)

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2 System RGLE- Series 80% A.F.U.E. Input Rates 75-125 kbtu ENER

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES FORM NO. GSC-493 REV. 3 Supersedes Form No. GSC-493 Rev. 2 GF902U*B SERIES Models with Input Rates of 45,000, 60,000, 75,000, 90,000 & 105,000 BTU/HR [13.19, 17.58, 22, 26.38 & 30.77 kw] 90 PLUS WITH DUAL

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS 50T35-743 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-490 GAS FURNACES RGLR- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information