Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES )

Size: px
Start display at page:

Download "Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES )"

Transcription

1 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES ) Product Data Single-Packaged Products with Energy -Saving Features and PuronR refrigerant. S 13 SEER S Up to 8.0 HSPF S Up to 11EER at 95_F OD S Factory -Installed TXV S Variable Speed Blower -Standard S Low Sound Levels Unit A99338 FEATURES/BENEFITS One -piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High -efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of Puron Environmentally Sound Refrigerant is Bryant s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. The most important advantage of Puron refrigerant is that it has not been banned in future air conditioning systems as the traditional refrigerant R -22 has been. Puron refrigerant is in service in over 100,000 systems proving highly reliable, environmentally sound performance. Comfort Heat Pumpt Technology with Perfect Humidityt featuring Variable Speed Blower motors provides better comfort and energy efficiency. You can expect up to 30 times better dehumidification; economical constant fan for less than $50 a year, which provides improved indoor airquality and more even temperatures from room to room; and reduced indoor noise due to lower air velocity. In addition, you ll realize improved installation flexibility with 3 different airflow choices for best overall comfort. Easy Installation Factory -assembled package is a compact, fully self -contained, heat pump unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard capacity ranges with voltage options to meet residential and lightcommercial requirements.units arelightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Convertible duct configuration Unit is designed for easy use in either downflow or horizontal applications. Each unit is easily converted from horizontal to downflow with the two standard duct covers. Durable, dependable componentscompressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. Direct -drive variable speed blower motor is standard on all models. Direct-drive, PSC condenser-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 55_F outdoortemperature.motormasterr II low ambient kit is available as a field installed accessory. Thermostat controls designed to work as a system with Carrier s small packaged product. Thermostatic Expansion Valve - A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. 1

2 Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Copper fin coils and pre-coated fin coils are available from the factory by special order. These coils are recommended in applications where aluminum fins are likely to be damaged due to corrosion. They are ideal for seacoast applications. Low sound ratingsensure aquiet indoorand outdoorenvironment with sound ratings as low as 72dBA. Easy to service cabinets provide easy single -panel accessibility to serviceable components during maintenance and installation. The base with integrated drain pan provides easy ground level installation with or without a mounting pad. Convenient hand -holds are provided to manipulate the unit on the jobsite. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4 -in. wide perimeter flange makes frame mounting on a rooftop easy. TABLE OF CONTENTS Features/Benefits Model Number Nomenclature... 3 ARI Capacities... 4 Physical Data... 4 Options and Accessories... 6 Base Unit Dimensions Accessory Dimensions Selection Procedure Performance Data Typical Piping and Wiring Application Data Electrical Data Typical Wiring Schematics Controls Guide Specifications Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal airflow mode. Cabinets are constructed of heavyduty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator adn electric heater compartments are insulated with cleanable semi -rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. Short -Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/-2 minutes) before restarting compressor after shutdown for any reason. 2

3 MODEL NUMBER NOMENCLATURE N X A A - - Type of Unit -Single Packaged Heat Pump Unit Electrical Supply N - 208/ P - 208/ Variations Nominal Cooling Capacity Tons Tons Tons Tons Tons Tons Heat Input Size (Btuh) , , , , ,000 Series Low NOx Indicator A - Standard N - Low NOx Options AD - Louver Grille BT - AL evap, vinyl condenser CC - AL evap, CU condenser CU - CU evap & condenser GS - Stainless Steel HX TP - Base unit with tin plated indoor coil hairpins TV - TP with vinyl coating on outdoor coil TC - TP with AL indoor coil & CU/CU outdoor coil See Price Page for full list of factory options. Only used if ordering an option LEGEND AL - Aluminum CU - Copper ISO 9001:2000 REGISTERED 3

4 ARI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT NOMINAL TONS STANDARD CFM NET COOLING CAPACITIES (Btuh) EER** SEER , / , , / , , , HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES UNIT HIGH HEAT CAPACITY 47_F (8.3_C) HIGH HEAT 47_F (8.3_C) LOW HEAT CAPACITY 17_F ( - 8.3_C) LOW HEAT 17_F (-8.3_C) , , , , , , , , , , , , HSPF LEGEND db - Sound Levels (decibels) db Dry Bulb SEER Seasonal Energy Efficiency Ratio wb Wet Bulb COP-Coefficient of Performance HSPF-Heating Season Performance Factor * Air Conditioing & Refrigeration Institute. **At A conditions-80_f (26.7_C) indoor db/67_f (19.4_C) indoor wb &95_F (35_C) outdoor db. { Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or ARI Standards 210/ Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80 F (26.7_C) db, 67 F (19.4_C) wb indoor entering-air temperature and 95 F (35_C)dboutdoorentering-airtemperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. PHYSICAL DATA - UNIT UNIT SIZE NOMINAL CAPACITY (ton) OPERATING WEIGHT (lb) OPERATING WEIGHT (kg) COMPRESSOR QUANTITY 1 TYPE SCROLL COMPRESSOR REFRIGERANT R-410A REFRIGERANT METERING DEVICE Indoor - TXV Outdoor - AccuRater Refrigerant (R-410A) Quantity (lb) Quantity (kg) METERING DEVICE ID TXV TXV TXV TXV TXV TXV ORIFICE OD (in.) ORIFICE OD (mm) (2) (2) (2) (2) (Left OD Coil) (.97 mm) (Right OD Coil)(1.2 mm) OUTDOOR COIL Rows... Fins/in face area (sq. ft.) OUTDOOR FAN Nominal Airflow (CFM) Diameter Motor HP (RPM) INDOOR COIL Rows... Fins/in. face area (sq. ft.) INDOOR BLOWER Nominal Airflow (CFM) Size (in.) Size (mm) Motor (HP) HIGH-PRESSURE SWITCH (psig) Cutout Reset (Auto) LOSS - OF - CHARGE/LOW - PRES- SURE SWITCH (Liquid Line) (psig) Cutout Reset (Auto) /8 (825) x10 254x254 1/ /8 (825) x10 254x254 1/ /8 (825) x10 279x254 3/ /8 (825) x10 279x254 3/ /4 (1100) x10 279x254 3/4 610±15 420±25 20±5 45± (Left OD Coil) (1.1 mm) (Right OD Coil)(1.3 mm) /4 (1100) x10 279x RETURN-AIR FILTERS (in.)*{ 20x24x1 20x24x1 24x30x1 24x36x1 24x36x1 24x36x1 throwaway *Required filter sizes shown are based on the larger of the ARI (Air conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high-capacity type. Air filter pressure drop for non-standard filters must not exceed 0.08 in. wc. { If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity. 4

5 OUTDOOR SOUND: OCTAVE BAND DATA -DECIBELS UNIT Capacity Sound Rating* dba Frequency (Hz) db *Tested in accordance with ARI Standard (not listed inari). 5

6 OPTIONS AND ACCESSORIES Factory-installed options Louver grille provides hail and vandalism protection. A wire grille isstandard on allmodels. Seemodel numbernomenclature forlouver grille options. Coil options include copper/copper and vinyl-coated construction for refrigerant coils. Units are shipped standard with copper tube/ aluminum fin construction. See model number nomenclature for coil options. Field -installed accessories Economizer with Solid -State Controls and Barometric Relief Dampers Manual Air Damper (25% open) Electric Heaters Filter Rack Flat Roof Curbs (8 -in. and 14 -in.) Square -to -Round Duct Transition Kit Thermostats Controls Upgrade Kit Crankcase Heater Compressor Hard Start Kit (for use on single -phase units only) Rigging Kit Low Ambient Kit (Motormaster II Control) Solid -State Time Guard II Device Economizer with solid -state controls and barometric relief dampers includes filter racks and provide outdoorair duringcooling and reduce compressor operation. Manual outside air damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. Electric heaters provide additional heat in the unit when required. Each package has a heater module that slides into the controls compartment. Heater sizes range from 5.0 to 20.0 kw. The electric heater design allows the use of a single-point power supply for the entire unit, resulting in lower installed costs. Filter rack features easy installation, serviceability, and high -filtering performance for vertical applications. Flat roof curbs in both 8 in. and 14 in. sizes are available for roof mounted applications. Square-to -round duct transition kit enables size units to be fitted to 14 in. round ductwork. Corporate Thermostats provide control for the system heating and cooling functions. Thermostat models are available in both programmable and non -programmable versions. Controls upgrade kit supplies high and low pressure safety protection and protects the unit from operating in unsuitable conditions. Crankcase heater provides anti-floodback protection for low - load cooling applications. Compressor hard start kit assists compressor start-up by providing additional starting torque on single phase units and prolongs compressor motor life. Rigging kit includes lifting brackets which are inserted into the unit base rigging holds to lift unit for rooftop applications. Low -ambient kit (Motormaster II control) allows the use of mechanical cooling down to outdoor temperatures as low as 0_Fwhen properly installed. Solid -state Time Guard II device provides short-cycling protection forthe compressor.not required with corporateelectronic thermostats. ELECTRIC HEATERS ODS CATALOG OR- DERING NO. NOMINAL USED WITH SIZES CAPACITY (kw) ELECTRIC HEATERS (208/230 SINGLE PHASE 60 Hz) CPHEATER052A X X X CPHEATER064A X X X CPHEATER070A X X X X X X CPHEATER050A X X X X X X CPHEATER066A X X X X X CPHEATER054A X X X ELECTRIC HEATERS (208/230 THREE PHASE 60 Hz) CPHEATER055A X X X X CPHEATER056A X X X CPHEATER068A X CPHEATER057A CPHEATER058A X X X X CPHEATER059A X X X NOTE: Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages. LEGEND ODS Order Distribution System Minimum Airflow for Reliable Electric Heater Operation (cfm) UNIT AIRFLOW

7 ECONOMIZER COIL FILTER FILTER ACCESS DOOR (HORIZONTAL APPLICATION ONLY.) DO NOT REMOVE FROM DOWNFLOW DISCHARGE. ECONOMIZER REPLACEMENT PANEL HOLE FOR ECONOMIZER WIRING HARDNESS 17 13/32 COIL SIDE VIEW CAULK BOTTOM CORNER OF ECONOMIZER ON EACH SIDE FI LTER ECONOMIZER DOOR LATCH ANGLE HINGED FILTER ACCESS DOOR 11 13/32 INSTALL FILTER ACCESS DOOR STICKER 16 1/4 RAINHOOD ALUMINUM FILTER BASE FLANGE ON BASE DETAIL FILTER RACK MANUAL OUTSIDE AIR DAMPER BEND FLANGE AT 90 -SCREW TO DIVIDER WITH 1-IN. SCREW REPLACEMENT PANEL EV APORATOR COIL TOP FILTER RACK MANUAL OUTSIDE AIR HOOD DAMPER BLADE BOTTOM FILTER RACK A

8 UNIT DIMENSIONS REQUIRED CLEARANCE TO COMBUSTIBLE MATL. (Refer to Maximum Operating Clearances) INCHES [mm] TOP OF UNIT [355.6] DUCT SIDE OF UNIT [50.8] SIDE OPPOSITE DUCTS [355.6] BOTTOM OF UNIT [12.7] NEC. REQUIRED CLEARANCES. INCHES [mm] BETWEEN UNITS, POWER ENTRY SIDE [1066.8] UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE [914.0] UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE [1066.8] REQUIRED CLEARANCE FOR OPERATION AND SERVICING INCHES [mm] EVAP. COIL ACCESS SIDE [914.0] POWER ENTRY SIDE [1066.8] (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP [1219.2] SIDE OPPOSITE DUCTS [914.0] DUCT PANEL [304.8] * *MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN [12.00] FROM WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE. A05162 UNIT ELECTRICAL UNIT WEIGHT UNIT HEIGHT CENTER OF GRAVITY IN. [MM] IN. [MM] CHARACTERISTICS lb kg A X Y Z NX / [991.1] 20.0 [508] 19.3 [489] 17.6 [447] NX / [991.1] 20.0 [508] 19.3 [489] 17.6 [447] (N,P)X / , 208/ [1041.9] 20.0 [508] 14.0 [355.6] 13.0 [330.2] 8

9 UNIT DIMENSIONS REQUIRED CLEARANCE TO COMBUSTIBLE MATL. (Refer to Maximum Operating Clearances) INCHES [mm] TOP OF UNIT [355.6] DUCT SIDE OF UNIT [50.8] SIDE OPPOSITE DUCTS [355.6] BOTTOM OF UNIT [12.7] NEC. REQUIRED CLEARANCES. INCHES [mm] BETWEEN UNITS, POWER ENTRY SIDE [1066.8] UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE [914.0] UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE [1066.8] REQUIRED CLEARANCE FOR OPERATION AND SERVICING INCHES [mm] EVAP. COIL ACCESS SIDE [914.0] POWER ENTRY SIDE [1066.8] (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP [1219.2] SIDE OPPOSITE DUCTS [914.0] DUCT PANEL [304.8] * *MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN [12.00] FROM WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE. A05126 UNIT ELECTRICAL UNIT WEIGHT UNIT HEIGHT CENTER OF GRAVITY IN. [MM] IN. [MM] CHARACTERISTICS lb kg A X Y Z (N,P)X / , 208/ [1091.7] 21.0 [533.4] 20.5 [520.7] 16.6 [421.6] (N,P)X / , 208/ [1142.5] 19.5 [495.3] 21.3 [539.8] 18.0 [457.2] (N,P)X / , 208/ [1193.3] 21.0 [533.4] 20.0 [508.0] 17.6 [447.0] 9

10 ACCESSORY DIMENSIONS HVAC unit base Screw (NO TE A) Gasketing inner flange* Screw (NOTE A) HVAC unit base Gask eting inner flange* *Gasketing outer flange *Gasketing outer flange Flashing field supplied Wood nailer* Roofcurb* Flashing field supplied Wood nailer* Roofcurb* Roofing material field supplied Insulation (field supplied) Roofing material field supplied Insulation (field supplied) Cant strip field supplied Duct wo rk field supplied Cant strip field supplied Duct wo rk field supplied Roof Roof *Provided with roofcurb *Provided with roofcurb Roof Curb for Small Cabinet Roof Curb for Large Cabinet Note A: When unit mounting scre w is used, retainer bracke t must also be used. Note A: When unit mounting scre w is used, retainer bracket must also be used. Supply opening (B x C) 44 5/16" B Typ. D C Typ. R/A S/A A Gasket around duct Insulated deck pan Long Support Short Support Insulated deck pan Gasket around outer edge Return opening (B X C) UNIT SIZE ODS CATALOG NUMBER A IN. (MM) B IN. (MM) C IN. (MM) C00076 D IN. (MM) CPRFCURB006A00 8 (203) 11 (279) 16-1/2 (419) 28-3/4 (730) CPRFCURB007A00 14 (356) 11 (279) 16-1/2 (419) 28-3/4 (730) CPRFCURB008A00 8 (203) 16-3/16 (411) 17-3/8 (441) 40-1/4 (1022) CPRFCURB009A00 14 (356) 16-3/16 (411) 17-3/8 (441) 40-1/4 (1022) NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 4. Dimension in ( ) are in millimeters. 5. Roof curb is made of 16-gauge steel. 6. Attach ductwork to curb (flanges of duct rest on curb). 7. Insulated panels: 1-in. thick fiberglass 1 lb. density. 8. When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic conditions. This bracket is available through Micrometl. 10

11 1 2 DETAIL A 3 4 A07216 Unit A05161 CORNER WEIGHTS (SMALL CABINET) CORNER WEIGHTS (LARGE CABINET) Unit lb kg lb kg lb kg lb kg lb kg lb kg Total Weight Total Weight Corner Weight 1 Corner Weight 2 Corner Weight 3 Corner Weight 4 Shipping Weight Corner Weight 1 Corner Weight 2 Corner Weight 3 Corner Weight 4 Shipping Weight SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at design conditions: Given: Required Cooling Capacity (TC)... 34,500 Btuh Sensible Heat Capacity (SHC)... 26,000 Btuh Required Heating Capacity... 60,000 Btuh Condenser Entering Air Temperature F Indoor-Air Temperature F edb 67 F ewb Evaporator Air Quantity CFM External Static Pressure in. wc Electrical Characteristics Select unit based on required cooling capacity. Enter Net Cooling Capacities table at condenser enteringtemperature of 95 F. Unit 036 at 1225 cfm and 67 F ewb (entering wet bulb) will provide a total capacity of 36,500 Btuh and a SHC of 27,600 Btuh. Calculate SHC correction, if required, using Note 4 under Cooling Capacities tables. 3. Select heating capacity of unit to provide design condition requirement. In the Heating Capacities and Efficiencies table, note that the unit will provide 70,000 Btuh with an input of 90,000 Btuh. 4. Determine fan speed and power requirements at design conditions. Before entering the air delivery tables, calculate the total static pressure required. From the given example, the Wet Coil Pressure Drop Table, and the Filter Pressure Drop Table: External Static Pressure in. wc Filter in. wc Wet Coil Pressure Drop in. wc Total Static Pressure in. wc Enter the table for Dry Coil Air Delivery At in. wc ESP (external static pressure) and NOM speed PIN selection, the motor delivers 1235 cfm. 5. Select unit that corresponds to power source available. The Electrical Data Table shows that the unit is designed to operate at 208/

12 PERFORMANCE DATA - STANDARD ECM INDOOR MOTOR Cooling Extended Performance Table 024 Cooling Performance Table Temp (F) Outdoor Air Entering Condenser Evaporator Air CFM/BF 800/ / /0.04 Evaporator Air Ewb (F) 62 63* * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw Heating Extended Performance Table Return Air (F db) Air Temperature Entering Outdoor Coil (F db at 70% rh) CFM (Standard Air) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw Heating Extended Performance Table Return Air Temperature Entering Outdoor Coil (F db at 70% rh) Air CFM (Standard Air) (F db) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw *At 75_F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F entering dry bulb. See Legend and Notes. 12

13 PERFORMANCE DATA (CONT)- STANDARD ECM INDOOR MOTOR Cooling Extended Performance Table 030 Cooling Performance Table Temp (F) Outdoor Air Entering Condenser Evaporator Air CFM/BF 875/ / /0.08 Evaporator Air Ewb (F) 62 63* * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw Heating Extended Performance Table Return Air (F db) CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) (Standard Air) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw Heating Extended Performance Table Return CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) Air (Standard Air) (F db) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw *At 75_F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F entering dry bulb. See Legend and Notes. 13

14 PERFORMANCE DATA (CONT)- STANDARD ECM INDOOR MOTOR Cooling Extended Performance Table 036 Cooling Table Temp (F) Outdoor Air Entering Condenser Evaporator Air CFM/BF 1100/ / /0.08 Evaporator Air Ewb (F) 62 63* * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw Heating Extended Performance Table Return Air (F db) Air Temperature Entering Outdoor Coil (F db at 70% rh) CFM (Standard Air) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw Heating Extended Performance Table 036 Return CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) Air (Standard Air) (F db) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw *At 75_F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F entering dry bulb. See Legend and Notes. 14

15 PERFORMANCE DATA (CONT)- STANDARD ECM INDOOR MOTOR Cooling Extended Performance Table 042 Cooling Performance Table Temp (F) Outdoor Air Entering Condenser Evaporator Air CFM/BF 1100/ / /0.08 Evaporator Air Ewb (F) 62 63* * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw Heating Extended Performance Table Return Air (F db) CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) (Standard Air) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw Heating Extended Performance Table 042 Return CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) Air (Standard Air) (F db) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw *At 75_F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F entering dry bulb. See Legend and Notes. 15

16 PERFORMANCE DATA (CONT)- STANDARD ECM INDOOR MOTOR Cooling Extended Performance Table 048 Temp (F) Outdoor Air Entering Condenser Evaporator Air CFM/BF 1260/ / /0.08 Evaporator Air Ewb (F) TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw Heating Extended Performance Table Return Air (F db) CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) (Standard Air) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw Heating Extended Performance Table 048 Return CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) Air (Standard Air) (F db) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw *At 75_F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F entering dry bulb. See Legend and Notes. 16

17 PERFORMANCE DATA (CONT)- STANDARD ECM INDOOR MOTOR Cooling Extended Performance Table 060 Temp (F) Outdoor Air Entering Condenser Evaporator Air CFM/BF 1500/ / /0.01 Evaporator Air Ewb (F) 62 63* * * TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw TC SHC kw Heating Extended Performance Table Return Air (F db) CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) (Standard Air) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw Heating Extended Performance Table 060 Return CFM Air Temperature Entering Outdoor Coil (F db at 70% rh) Air (Standard Air) (F db) TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw TC kw *At 75_F entering dry bulb Tennessee Valley Authority [TVA] rating conditions; all others at 80_F entering dry bulb. See Legend and Notes. 17

18 PERFORMANCE DATA (CONT) Economizer 1 -in. Filter Pressure Drop (in. wc) Multiplication Factors UNIT PRESSURE DROP HEATER kw RATING VOLTAGE DISTRIBUTION V/3/60 MULTIPLICATION FACTOR LEGEND BF Bypass Factor edb Entering Dry -Bulb Wet-bulb temperature corresponding to enthalpy lwb = air leaving evaporator coil ( h lwb) Ewb Entering Wet-Bulb kw Total Unit Power Input SHC Sensible Heat Capacity (1000 Btuh) lwb = h ewb - total capacity (Btuh) TC Total Capacity (1000 Btuh) (net) 4.5 x cfm rh Relative Humidity Where: h ewb = Enthalpy of air entering evaporator coil COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator-fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: t ldb = t edb - Sensible capacity (Btuh) 1.10 x cfm 4. The SHC is based on 80 F (26.6_C) edbtemperature of air enteringevaporator coil. Below 80 F (26.6_C) edb, subtract (corr factor x cfm) from SHC. Above 80 F (26.6_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. Electric Heat Pressure Drop Table Small Cabinet: cfm kw kw kw kw kw Electric Heat Pressure Drop Table (in. wc) Large Cabinet cfm kw kw kw kw kw Cooling & Heating Dry Coil ECM Airflow Small Cabinet CFM ADJUST PIN LO PIN NOM PIN HI PIN SELECT UNIT EXTERNAL STATIC SIZE PRESSURE RANGE (in. wc) COOLING* COOLING 024 DEHUMIDIFY HEAT PUMP COMFORT COOLING* COOLING 030 DEHUMIDIFY HEAT PUMP COMFORT COOLING* COOLING 036 DEHUMIDIFY HEAT PUMP COMFORT *Heat Pump Efficiency and Cooling pin selections deliver equal airflow 18

19 PERFORMANCE DATA (CONT) Cooling & Heating Dry Coil ECM Airflow Large Cabinet CFM ADJUST PIN SELECT LO PIN NOM PIN HI PIN UNIT SIZE EXTERNAL STATIC PRESSURE RANGE (in. wc) COOLING* COOLING DEHUMIDIFY HEAT PUMP COMFORT COOLING* COOLING DEHUMIDIFY HEAT PUMP COMFORT COOLING* COOLING DEHUMIDIFY HEAT PUMP COMFORT *Heat Pump Efficiency and Cooling pin selections deliver equal airflow ECM Wet Coil Pressure Drop (in. wc) UNIT STANDARD CFM (SCFM) SIZE Filter Pressure Drop Table (in. wc) FILTER SIZE CFM X20X X30X X36X

20 TYPICAL PIPING AND WIRING VERTICAL DISCHARGE ROOF-MOUNTING CURB ROOF RETURN-AIR FLEXIBLE DUCT SUPPLY-AIR FLEXIBLE DUCT CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) CEILING INDOOR THERMOSTAT RETURN AIR TOP COVER FROM POWER SOURCE FROM GAS LINE DISCONNECT PER NEC* *NEC - NATIONAL ELECTRICAL CODE 20

21 APPLICATION DATA Condensatetrap A 2 -in.condensatetrap mustbe field supplied. 1 MIN. TRAP OUTLET 2 MIN. C99013 Ductwork Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge Units are equipped with factory -installed inserts in the downflow openings. Removal of the inserts is similar to removing an electrical knock -out. Units installed in horizontal discharge orientation do notrequire ductcovers. Maximum cooling airflow To minimize the possibility of condensate blow -off from the evaporator, airflow through the units should not exceed 450 cfm per ton. Minimum cooling airflow Minimum cooling airflow is 350 cfm per ton in cooling mode. Airlow can belower in certain modeswhen humidity removal is an issue. Minimum ambient cooling operation temperature Allstandard units have a minimum ambient cooling operating temperature of 55_F (12.8_C). With accessory low ambient temperature kit, units can operate at temperatures down to 0_F (17.8_C). Maximum operating outdoor air temperature for cooling is 125_F (51.7_C). Balance Point Worksheet 70 Based on Entering Indoor Air of 70 Deg. F and Rated CFM Building Heat Loss, 1000BTUH Unit Intetgrated Heating Capacity, 1000BTUH Outdoor Air Temp (Deg F) C

22 ELECTRICAL DATA Electrical Data UNIT SIZE V-PH-Hz VOLTAGE RANGE COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR Min Max RLA LRA FLA FLA / / / / / / / / / / See Legend and Notes on next page. ELECTRIC HEAT NOMI- NAL kw / 3.8/ / /10.0 / 3.8/ / / /15.0 / 3.8/ / / /15.0 / 3.8/ / /15.0 / 3.8/ / / / /20.0 / 3.8/ / / /20.0 / 3.8/ / / / /20.0 / 3.8/ / / /20.0 / 3.8/ / / / /20.0 / 3.8/ / / /20.0 FLA / 18.1/ / /41.7 / 18.1/ / / /62.5 / 18.1/ / / /62.5 / 10.4/ / /36.1 / 18.1/ / / / /83.3 / 10.4/ / / /48.0 / 18.1/ / / / /83.3 / 10.4/ / / /48.0 / 18.1/ / / / /83.3 / 10.4/ / / /48.0 UNIT MCA 22.1/ / / / / / / / / / / / / / /23./ 36.7/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /92.6 POWER SUPPLY MAX FUSE OR CKT BKR 30/30 60/60 30/30 35/35 30/30 50/50 60/60 45/45 35/35 60/60 45/45 35/35 60/60 60/60 40/40 60/60 MOCP 70/70 80/80 60/70 70/80 80/90 100/110 70/70 80/80 90/90 100/110 70/80 80/80 90/90 100/ / /150 70/70 80/80 90/100 80/80 90/90 100/ / /150 70/70 80/80 90/90 90/ / / / /175 70/70 80/80 90/90 22

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) 607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data A09033 Fig. 1 - Unit 607C - -A Single-Packaged Products

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron Performancet 13 SEER Single---Packaged HYBRID HEATr Dual Fuel System with Puronr (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 024---060) Product Data C99088 Fig. 1 - Unit Single-Packaged

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single --- And Three ---Phase Units 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant Product Data Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons Single-Packaged Products with Energy-Saving Features and

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Model 704B Sizes

Model 704B Sizes SINGLE-PACKAGED ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant Model 704B Sizes 024-060 2 To 5 Nominal Tons UNIT 704B Single-Packaged Products with Energy-Saving Features and Puron refrigerant.

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. Low

More information

Product Data. Unit 574D

Product Data. Unit 574D SINGLE -PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R -410A) REFRIGERANT SINGLE- AND 3 -PHASE UNITS 1-1/2 to 5 NOM TONS (SIZES 018-060) Product Data Single-Packaged Products with Energy -Saving

More information

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. Fig. 1 - Unit 50ES -A

Product Data. Fig. 1 - Unit 50ES -A 50ES---A Comfortt 13 SEER Single---Packaged Air Conditioner tem With Puron (R---410A) Refrigerant Single and Three Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50ES -A A09034

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3 SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS Model 702A 2 to 5 Nominal Tons UNIT 702A Single packaged Cooling Unit for Residential and Light Commercial use. FEATURES/BENEFITS One-piece cooling unit with

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons Product Data 50GS Single-Packaged Electric Cooling Units 1-1/2 to 5 Nominal Tons UNIT 50GS Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data. Fig. 1 - Unit 50VL -A

Product Data. Fig. 1 - Unit 50VL -A 50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single--- And Three---Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50GL Single-Package Products with Energy-Saving Features and Puron refrigerant. Low Sound

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES )

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES 024-060) Product Data Fig. 1 - Unit A06079 Single-Packaged Products with Energy

More information

Product Data. Fig. 1 - Unit 50XL -A

Product Data. Fig. 1 - Unit 50XL -A 50XL---A Infinityr 15 SEER Single---Packaged Air Conditioner with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50XL -A A09032 Single-Packaged

More information

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons Product Data Convertible duct configuration Unit is designed for easy use in either downflow or horizontal

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits Product Data 50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant 7 to 14 kw (2 to 4 Nominal Tons) UNIT 50GL (50HZ) Single-Packaged Products with Energy-Saving Features

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information

Model 574B Sizes

Model 574B Sizes SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 574B Sizes 024-060 2 to 5 Nominal Tons Low NOx Models Available UNIT 574B Single-Packaged Rooftop Products with Energy-Saving Features and Puron

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. Features/Benefits

Product Data. Features/Benefits , N 3-PHASE SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Rooftop Products with Energy-Saving Features and

More information

Product Data. Features/Benefits

Product Data. Features/Benefits PERFORMANCE 13 (N) SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant Scroll

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Product Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE

Product Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R- REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES 024-060) 1 & 3 PHASE Product Data Convertible duct configuration Unit is designed for easy use in either

More information

Product Data. Fig. 1 - Unit 50VL -A

Product Data. Fig. 1 - Unit 50VL -A 50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033 Single-Packaged

More information

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits Product Data 50ZH Single-Packaged Heat Pumps 2 to 5 Tons Single-Package Heat Pump Units with: easy installation design corrosion-proof basepan redesigned aerodynamic fan blade for reduced sound sloped

More information

Product Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

Product Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data Fig. 1 - Unit - -A A09183 Single-Packaged Products with Energy

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit

More information

Product Data. Fig. 1 - Unit 48XL -A

Product Data. Fig. 1 - Unit 48XL -A 48XL---A Infinity 15 SEER Single---Packaged Air Conditioner and Gas Furnace with Puron (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 48XL -A A09032

More information

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons Product Data 50SX High Efficiency Single-Packaged Cooling Units 2 to 5 Nominal Tons 50SX High Efficiency, Single-Packaged Cooling Unit for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons Product Data 50LJQ Single-Package Rooftop Heat Pump Units Nominal 3 to 10 Tons Single-Package Rooftop Heat Pump Units with the following Standard Features: 2-in. return-air filters Acutrol refrigerant

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES FACTORY- ASSEMBLED PACKAGE is a compact, fully self-contained, electric cooling unit with horizontal supply and return ducts. The PA1Z units are available in a variety of standard cooling sizes with voltage

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial

More information

Model 583A Sizes

Model 583A Sizes SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 583A Sizes 024-060 2 to 5 Nominal Tons UNIT 583A Single-Packaged Rooftop Products with Energy-Saving Features. Direct Spark Ignition Low Sound Levels

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp. PHE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE HEAT PUMP UNIT - 13 & 15 Ton REFRIGERATION CIRCUIT Single reciprocating semi -hermetic compressor on all 13 ton units. Dual semi -hermetic compressors

More information

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION Bryant Air Conditioning Model 581A COMMERCIAL SINGLE PACKAGE ROOFTOP Sizes 155-240 GAS HEATING/ELECTRIC COOLING UNITS 13 to 20 Tons Model 581A155,180 Model 581A240 DESCRIPTION The 581A gas heating/electric

More information

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons Product Data 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units 2 to 5 Nominal Tons UNIT 48GX (Shown with Accessory Wire Grille) Single-Package Rooftop Products with Energy-Saving Features. Direct

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006 Product Data FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant Sizes 002 thru 006 A02332 Premium Environmentally Sound Fan Coil The latest in technology makes the FV4B the most advanced air

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

50TJM 60Hz Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM 60Hz Nominal Cooling Capacity Tons HFC R - 410A Refrigerant Package Rooftop Units 60Hz Quality Assurance Certificate Reg. No: 04 100 950420 Product Data Catalog Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation:

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

Advanced Product Data

Advanced Product Data 48PD and 50PD-05, 06 Displacement Ventilation or Single-Zone Variable Airflow Rooftop Units Single Package, Electric Cooling, Gas or Optional Electric Heating with PURON (R-410A) Refrigerant and COMFORTLink

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Models 566D 569C,576B with 524A 6to30Tons

Models 566D 569C,576B with 524A 6to30Tons Bryant Air Conditioning COMMERCIAL AIR-COOLED CONDENSING S WITH 524A AIR-HANDLING S Models 566D 569C,576B with 524A 6to30Tons DESCRIPTION Model 569C condensing units are available in nominal 6- to 10-ton

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons

Product Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons Product Data 50BYN Single-Package Air Cooled Vertical Packaged Units 5to20Tons The 50BYN units are single-package cooling units with integral air-cooled condensers designed for indoor installations. They

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information