120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V
|
|
- Roxanne Chambers
- 5 years ago
- Views:
Transcription
1 Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, R7 Size Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V (Hz) 5V (Hz) uilt-in transformer 7 9 Port size How to Order Voltage 0V V 0V V Note ) Select one applicable voltage. Options (No options for standard specification models) Options (No options for standard specification models) X0 X0 X05 The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. M R W Option Voltage 7 9 Note ) Possible to combine options. When requiring options or more, it is made to order. M R W With anticorrosive treatment With motor operated auto drain With circuit breaker Watercooled condenser H T X0 X0 X05 I ir compressor Refrigerant 70 70kW R 70 flange Voltage Three 00V 70 (/Hz) Option Size 70 With circuit braker With Heavy anti-corrosive duty auto treatment drain MG Integrated with Transformer (Option) I 70 ir compressor Refrigerant 70 70kW R 70 9 flange Primary side at transformer 0V V 0V 0V 5V V M Misc. -7-
2 Series I Large The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. Standard Specifications/s Specification Rated conditions Operating ranges lectrical specifications Note ) ir flow rate (m /min (NR)) Inlet air pressure (MPa) Inlet air temperature ( ) mbient temperature ( ) Outlet air pressure dew point ( ) Working fluid Power source Power consumption (kw) ircuit breaker () ondenser Refrigerant uto drain Weight (kg) oating color pplicable compressor (kw) Hz Hz Inlet air temperature ( ) Inlet air pressure (MPa) mbient temperature (Humidity) ( ) ir connection rain connection (Rc) 00V 0V 5V 00V 0V V Hz Hz Hz I0 I I ompressed air 5 to 0.5 to 0. I to (Relative humidity of 5% or less) Three 00/0V (/Hz) Three 0V (Hz) Three 5V (Hz) ir cooled R / flange flange flange Rc / Three 00/0V (/Hz) Three 0V (Hz) Three 5V (Hz) H00-0 ody panel: Munsell 0Y/0.5 (White) ase: lack 0 90 I70 Three 00/0V (/Hz) Water cooled R flange Rc / M Note ) to ront panel: Munsell.5P5/.5 (lue) Other panels (xcept base): Munsell N- (White) Water cooled condenser specifications (I70) ondenser Shell and tube system Note ) ooling water flow 00 l/min Note ) ooling tower capacity 0RT Pressure style automatic Water flow regulator water supply valve onnection bore on water side / union Note ) Value for inlet water temperature of and rated load. Note ) Value calculated for RT =, 0kcal/h. uto drain I70 Power supply Power consumption JIS Refrigerated air dryer uto drain Operation cycle Operation time cycles/min. sec./min. 00V /Hz. W Note ) The data for l/min (NR) refers to the conditions of 0, atm. pressure and relative humidity of 5%. Note ) This is made to order. Operation Principles I0 to ompressed Pressure gauge ir reheater ir cooler I70 ompressed (humid and high ompressed temperature air) (dry and warm air) ondenser ccumulator Volume control valve Temperature expansion valve ompressed uto drain vaporation thermometer Low pressure switch rain apillary tube ompressor High pressure switch ondenser an motor Volume control valve Pressure switch ir reheater ir cooler rain utomatic water supply valve Water cooled condenser Motor operated auto drain High temperature humid air is cooled in the reheater. Then it is further cooled to a specified temperature using the evaporation heat in the air cooler. The oil mist and moisture occurring due to condensation is exhausted through the auto drain. ooled and dehumidified air is returned to the air reheater and heat is transferred from the incoming high temperature air. It is then exhausted out of the air dryer as dry air. -7-
3 The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. Refrigerated ir Series I I0,, 90, Ventilation direction Large K (0) 00 (JIS 0K) Ventilation direction Ventilation direction Ventilation ompressed 00 J Power supply cable entry ompressed Rc / G nchor bolt hole -ø0 H I I0 I I90 I JIS 0K / lange JIS 0K lange JIS 0K lange JIS 0K lange G H I J K uto drain is packed together with air dryer. (Some assembly is required.) I70 ompressed (0) (0) ompressed (JIS 0K ) (0) Power supply cable entry H 70 T 00 ooling water outlet (Rc /) (90) I MG () (00) ooling water inlet (Rc /) (90) (90) 0 0 (0) Rc / nchor bolt hole -ø0 M Misc. -7-5
4 Series IU/I Option Specification The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. Refer to pages -7-,,,0 and for "How to order" of options. ool compressed air output at 0 The air flow with this option is lower than that of the standard dryer. On models I to 5, the and outlet are reversed. xcept for I to, piping dimensions of the and outlet are different from standard. (Refer to pages 9, and 5.) ir flow capacity (l/min (NR)) /Hz ir flow capacity (l/min (NR)) /Hz ir flow capacity (l/min (NR)) /Hz I 5 00 I 0 I 5 I 0 I 5 0 I7 nti-corrosive treatment With evaporation thermometer H or medium air pressure I 0 0 I 7 I 5 I 5 I I 5 Hz Hz [ondition I] Pressure: 0.7MPa, Saturation: 5 mbient temperature:, Outlet air temperature: 0 [I to ] Pressure: 0.7MPa, Saturation:, mbient temperature:, Outlet air temperature: 0 This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. This option extends the service life. Special epoxy coating of copper tube and copper alloy parts. The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by coating. Note ) or I70, option is assigned as X0. thermometer (pressure gauge) indicating the evaporating temperature of the refrigerant is attached to the operation panel, facilitating maintenance and daily checks. IU to, I to 70 standard. This option provides a heat exchanger, auto drain, air pressure gauge and ball valve, etc., with a medium pressure capability. This is different from the standard specifications. Maximum operating pressure is.5mpa. L Hz Hz Hz Hz With heavy duty auto drain dryer with heavy duty auto drain (H00-0) is installed instead of the float type auto drain (IN0--0), which is used for standard models to discharge drainage. I0,,90, standard. Note ) or I70, option L is assigned as X IU IU IU IU5 IU IU7 IU IU I I I I5 I I7 I I I0 I I90 I M With motor operated auto drain This option changes the float style auto drain (IN-0--0) used by standard air dryers to a motor operated auto drain (M00-0) where by drainage is discharged more precisely. Operating air pressure ir discharge if no drainage 0.MPa l (NR) each time 0.5MPa 0 l (NR each time 0.7MPa l (NR) each time Operation cycle: cycle/min. Operation time: sec./min. I0 to 70 standard. R () () With circuit breaker IU IU IU IU5 IU IU7 IU IU I I I I5 I I7 I I I0 I I90 I circuit breaker with bowl is attached to the side of the air dryer. This saves additional electrical wiring at the time of installation. (I0 to 70 do not have an electric leakage detection function.) IU to I70 I to I0 to No fuse breaker () Ground fault circuit breaker with bowl IU, I IU, I IU, I IU5, I5 IU, I IU7, I7 IU, I IU, I I0 I I90 I I70 rain discharge port Rc / Motor operated auto drain () Motor operated auto drain is packed together with main unit. ssembly is required. X0 (I0, 70) reaker capacity 0 (00V) 5 (00V) Power cord outlet ø5 Sensitivity current 5 to m
5 The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. Option Specification S With power cord connection W Water cooled condenser (I7 to ) This option allows connection of the power supply to a terminal board (P). IU,, I to 5 Terminal board 5 IU to 5, I to 5 T With the optional terminal, in addition to connection of the power supply, the air dryer can be started and stopped by remote control and an operation failure signal can be obtained. (If no voltage contact is made, an operation failure signal will register.) I0 to 70 standard. IU, I, IU IU IU IU5 IU IU7 IU IU 7 Power cord outlet Power cord outlet (ø7) Grommet with waist I I I I5 I I7 I I 5 5 IU IU I I I I IU IU IU IU5 I I I I With terminal block for run & alarm signal and remote operation Power cord outlet (ø7) Grommet with waist Signal cord outlet (ø7) Grommet with waist ront side IU to I to 9 9 Signal cord outlet (ø7) Grommet with waist Power cord outlet Grommet with waist ø to This option can be used where the ambient temperature is high (Max. ), and does not reduce air flow capacity. It is also possible to use this option in an enclosed environment to prevent increasing of the surrounding temperature. I70 standard. W: Water cooled condenser (I7 to ) ondenser type ooling water flow l/min Note) ooling tower capacity RT Note ) Water flow regulator onnection bore on water side (union) I ooling water outlet ooling water inlet ompressed air pressure gauge rain Rc / With plug I7 I I I0 I I90 I / / Shell & coil system 0 / Pressure auto feed valve Note ) Value for inlet water temperature of and rated load. Note ) Value calculated for RT =, 0kcal/h. I0 to ack side Transformer integrated I7 I I ooling water outlet ompressed air pressure gauge ooling water inlet rain with plug Rc / The power supply transformer can be integrated with an air dryer. It is used when a refrigerated air dryer is using a non-standard voltage specification. The power supply transformer for I0 to is installed inside of the air dryer. Therefore, external dimensions are the same as the standard product. (795) (5) Transformer box Power cord outlet (ø) H T I MG M Misc. () 700 ± () I70 -ø0 (nchor bolt hole) -7-7
6 Transformer separately installed escription eatures This is for power supply and voltage other than standard. The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. ccessories (Option) Specifications Max. ambient temperature (Relative humidity 5% or less) pplicable dryer ll models imensions -7- ase integrated with transformer This is the base for integrating the transformer and air dryer. IU to5 I to -7- ust proof filter set voids decreasing of air dryer performance even in dusty atmosphere. Max. ambient temperature IU to I to -7- ypass piping set asy bypass piping (connect this set to the air dryer), realizing substantial reduction of man-hours at the site. Max. operating pressure.0mpa Max. operating temperature IU to I to -7- How to Order Transformer separately installed I TR 0 5 ase integrated with transformer I T Volume Volume 0 0V 000 kv 0.5kV kv 7kV 9kV kv kv kv ust proof filter set IU pplicable dryer I IU IU pplicable dryer I I I I I pplicable dryer 0 90 I0 I I90 I -7- pplicable dryer IU- to-, I- to- IU5-, I5- IU-, 7-, I-, 7- IU-, -, I-, - I0 I I90 I I70 L 5 L 5 L 0 IU IU IU IU5 I I I I5 Supply voltage Primary voltage 0V (Hz), 0 to 0V 00, 0,, V (Hz), 00 to V 0, 0, 5V (Hz), 0 to 0V 0,, 0V (Hz), 0 to 50V 0V (Hz), 5 0 to V 0, 0, 5V (Hz), 0 to V (HZ), V (Hz), 7 to 0V 0,, 0, 0, 5, V (/Hz) Refer to page -7-9 for dimensions. 7 7 IU IU7 IU IU I I7 I I Secondary voltage 00V (Hz) 00 to 0V 00V (Hz) 00 to 0V 00V (/Hz) IU ypass piping set pplicable dryer I IU IU Three Three pplicable dryer I I I I turn ompound turn ompound P 5 P 5 IU IU IU IU5 I I I I5 Size order pplicable dryer IU, I IU to 5, I to 5 I I7 to Not available for I to, IU to. Refer to page - 7- for dimensions. 7 7 IU IU7 IU IU I I7 I I annot be mounted on models with option (I to ). vailable as Special Order Product.
7 The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. ccessories (Options) Transformers I-TR - OUT PUT IN PUT - I-TR - Input cord m I-TR0- I-TR000- I- to - IU- to - I5- IU5- apacity 0V kv turn Primary voltage 0V (Hz) 0 to 0V Secondary voltage 00V (Hz) 00 to 0V Weight (kg). x 7.5 (Long hole). x 9 (Long hole) OUT PUT 0V VOLUTG IN PUT SLTOR - I-TR -, Input cord m I-TR0- I-TR000- I- to - IU- to - I5- IU5- apacity 0V kv turn Primary voltage 00, 0, V (Hz) 00 to V Secondary voltage 00V (Hz) 00 to 0V x 0 (Long hole) Weight (kg) 0 VOLUTG SLTOR US OUT PUT IN PUT I-TR ø Input cord m Terminal block I-TR0- I-TR000- I-TR0- I-TR000- I- to - IU- to - I5- IU5- I to - IU to - I5- IU5- apacity Primary voltage Secondary voltage 0V kv 0V kv turn 0, 0, 5V (Hz) 0 to 0V 0,, 0V (Hz) 0 to 50V 00V (Hz) 0V Weight (kg) 5 5 ø5 07 apacity Primary voltage Secondary voltage Weight (kg) I-TR -5,, 7 Terminal block ø 0 I-TR - -ø -ø 0 I-TR0-5 apacity I-TR0- I-TR0-7 I-, 7-.5kV IU-, 7- I-, 7-.5kV IU-, 7- I-TR00-5 I-TR00- I-TR00-7 I- I7- IU- IU7- I-, - IU-, - I-, - IU-, - I-, - IU-, -.5kV kv kv kv Three turn Three turn 0V (Hz) 0 to V Primary voltage 0, 0, 5V (Hz) 0 to 0, 0 to 5, 5 to V, V (Hz) to, to 0V 0V (Hz) 0 to V Secondary voltage 00V (Hz) 00 to 0V 00V (Hz) 00 to 0V 00V (Hz) 00 to 0V 0, 0, 5V (Hz) 0 to 0, 0 to 5, 00V (Hz) 5 to V 00 to 0V, V (Hz) to, to 0V 00V (Hz) 00 to 0V 00V (Hz) 00 to 0V 9 Weight (kg) H T I MG M Misc. øg -ø I-TR7000- I-TR9000- I-TR000- I-TR00- I-TR000- I0 I I90 I I70 apacity 7kV 9kV kv kv kv Three compound Primary voltage 0,, 0, 0, 5, V (/Hz) Secondary voltage 00V (/Hz) G Weight (kg)
8 ccessories (Options) The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. ase Integrated with Transformer I-T I-T I I7 I I Transformer I-TR0-5 I-TR0- I-TR0-7 I-TR0-5 I-TR0- I-TR0-7 I-TR00-5 I-TR00- I-TR00-7 I-TR00-5 I-TR00- I-TR00-7 -ø ase integrated with transformer Transformer separately installed G H G H () Weight (kg) I-T I-T I- IU- I- I- I- I5- IU- IU- IU- IU- IU5- Transformer I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR000- I-TR000- I-TR000-. I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR0- I-TR0- I-TR0-. I-TR000- I-TR000- I-TR G H 7 7 Weight (kg) ust proof filter set Note) Weight includes air dryer and transformer. Not available for I to, IU to. (5) () (5) (0) () I-L,,,, IU-L, (I-L,,, 5) -7- I-L I-L I-L I-L I-L I-L I-L I-L5 I-L I-L7 I-L I-L I-L0 I-L I-L90 I-L I I I I I I I I5 I I7 I I I0 I I90 I IU-L IU-L IU-L IU-L IU-L IU-L5 IU-L IU-L7 IU-L IU-L IU IU IU IU IU IU5 IU IU7 IU IU or IU-L to, pcs. are set. or I-L0 to, pcs. are set.
9 The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. ccessories (Options) ypass Piping Set IU, ompressed ompressed I,,, ompressed ompressed () () () () () () pplicable dryer Rc IU-P IU-P pplicable dryer IU IU Rc / I-P I-P I-P I-P I I I I / IU,,, 5,, 7,, ompressed ompressed I,,, 5,, 7,, () () () ompressed ompressed () () () () () () H () T I MG IU-P IU-P IU-P IU-P5 IU-P IU-P7 IU-P IU-P pplicable dryer IU IU IU IU5 IU IU7 IU IU Rc / / / / pplicable dryer Rc I-P I-P I-P I-P5 I-P I-P7 I-P I-P I I I I5 I I7 I I / / / / annot be mounted on models with option "" M Misc. -7-
10 Technical ata Pressure dew point ondensed water calculation The models I to and IU to have been revised. or details, refer to catalog no. S-. Similar updating for other I/IU models is scheduled to follow shortly. 0% Relative humidity 00% % % 0% mount of water in air g /m 5 5 mount of condensed water tmospheric pressure 0.MPa = 5.g/m Intake air temperature (atmospheric pressure) ir temperature (Pressure dew point) [xample] If air at and % humidity is pressurized to 0.7MPa, the dew point of the air will be. ( ) If this is cooled to 5, the amount of condensed water generated will be 5.g/m. ( ) Therefore, with an air flow rate of m/min (kw equivalent compressor), the amount of condensed water per unit of time is 5. x x = 7g/h. ew point conversion chart Pressure dew point MPa.MPa.MPa 0.9MPa 0.7MPa 0.5MPa 0.MPa 0.MPa tmospheric pressure tmospheric pressure dew point -7-
11 Series IU/I Specific Product Precautions ir Preparation quipment Precautions e sure to read before handling. aution Installation Location void locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is more than 5%) void exposure to direct sunlight. void dusty or corrosive environments. Wind If it is used in Rain the above environments, select option (with anticorrosive treatment). ust orrosive gas void places with poor ventilation and high temperature. way from the wall! void locations subjected to vibrations. void locations where drainage can freeze. Use the air dryer with an ambient temperature lower than. void installation on moving objects like trucks, ships, and so forth. aution rain Tube llow ample space around the air dryer. polyurethane tube of 0mm outer diameter is attached as the drain tube for I to and IU,. Use this tube to discharge drainage. o not use the drain tube in an upward direction. o not bend or crush the drain tube. (Operation of auto drain will stop and water will flow out through the air outlet.) aution Power Supply <00V> Insert the power supply plug into an exclusive 00V power outlet. Install a circuit breaker (0) at the power supply. e sure to ground the power supply prior to use. Multiple-branch wiring is dangerous as it causes over-heating. o not extend the power supply cord length using an extension cord. voltage drop may cause the air dryer to stop operating. Use a circuit breaker having a sensitivity current of m or less and a rated current of 0. xclusive 00V power outlet <00V> onnect the power supply to the terminal block. Install a suitable circuit breaker applicable to each model. aution e careful to avoid errors in connecting the air piping to the compressed (IN) and outlet (OUT). Install bypass piping which it is needed for maintenance. ompressed Valve open ir Piping ypass valve closed I to IU to ompressed Valve open I to IU, Install circuit breaker (0) Grounding When the voltage used is other than specified in the standard product specifications, use a transformer (page -7-). Valve closed Valve open When tightening piping at the air inlet/outlet tube, the nozzle should be held firmly with a pipe wrench. (I to, IU to ) Variation of operating conditions may cause condensate to form on the surface of the outlet piping. In the case of models larger than I and IU, roll thermal insulation around piping to prevent condensate from forming. Vibration caused by the compressor should not be transmitted through air piping to the air dryer. o not allow the weight of piping to be applied directly to the air dryer. -7- H T I MG M Misc.
12 Series IU/I Specific Product Precautions ir Preparation quipment Precautions e sure to read before handling. aution Protection ircuit When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. When compressed air temperature is too high When compressed air flow rate is too high When ambient temperature is too high ( or higher) When power supply is beyond rated voltage by ±0% When ventilation port is obstructed by a wall or clogged with dust aution ompressor ir elivery Use an air compressor of 00 l/min or greater air delivery with I to /IU,, and 0 l/min or greater air delivery with I to /IU to. aution Time elay for Restarting llow at least three minutes before restarting the dryer. If the air dryer is restarted within three minutes after being stopped, the protection circuit will be activated, the operating light goes off and the dryer will not be activated. aution rank ase Heater Please wait three minutes! crank case heater is installed on I70. nergize the crank case heater hours prior to operation of the dryer to prevent trouble occurring in the refrigerant compressor. Since the auto drain of I to /IU to is designed in such a way that the valve remains open unless the air pressure rises to 0.5MPa or higher, air will blow out from the drain discharge port when the air compressor starts up until the pressure increases. Therefore, if an air compressor has a low air delivery, the pressure may not be sufficient. aution uto rain The auto drain may not function properly, depending on the quality of compressed air. heck its operation once a day. leaning of Ventilation rea aution Remove dust from the ventilation area once a month using a vacuum cleaner or an air blow nozzle. -7-
IDU22C, 22C1, 37C, 37C1, 55C, 75C
Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port
More informationRefrigerated Air Dryer
T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved
More informationINDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)
Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRefrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationRefrigerated Air Dryer
Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])
More informationRefrigerated Air Dryers
Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationRefrigerated Air Dryers
Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic
More informationRefrigerated Air Dryers
Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationRefrigerated Air Dryers
Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRefrigerated Air Dryer Large Size Series
Refrigerated ir Dryer Large Size Series E Directive compliant (with E marking) For use in Europe, sia and Oceania Power Three-phase 380 V (For sia and Oceania) supply voltage Three-phase 400 V (For Europe)
More informationRefrigerated Air Dryer Large Size Series
ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Refrigerated ir Dryer Large Size Series IDF25F/50F are added! New Model IDF00F- IDF00F--W
More informationRefrigerated Air Dryer
Refrigerated Air Dryer Large Size Series Tolerant of high temperature environment! Top of its class in the industry for the large air-cooled type Ambient temperature 45 Inlet air temperature 60 Energy
More informationWith air temperature adjustment function. Application example. with constant conditions to air bearings mounted on the tool. Compressed.
Thermo-dryer With air temperature adjustment function New RoHS Stable supply of temperature and pressure controlled dry clean air! Possible to supply compressed air with the same conditions and quality
More information% by up ctoond re-heater and
Refrigerated Air Dryer 100FS/125FS/150FS Series Saves energy 76 % by up ctoond re-heater and Digital scroll compressor Stainless steel heat exchanger Ozone depletion potential ZERO refrigerant RoHS HAA
More informationRefrigerated Air Dryer
Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3
More informationRefrigerated Air Dryer
Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,
More informationRefrigerated Air Dryer
Refrigerated Air Dryer For Use in Southeast Asia Applicable for the high-temperature environments of tropical regions Can be used in high-temperature environments Ambient temperature : Max. 45 C Inlet
More informationPrevents condensation
Moisture Control Tube Series Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor dditional power supply and works are not necessary!
More informationAir Cooled Scroll Chiller
ir ooled Scroll hiller Midea chillers use V shape heat exchanger and single unit s capacity from 30kW to 250kW.They are divided to PS, PS-L,PS-HM and PS-HML series according to their operation ambient
More informationOutstanding Performance; Application Flexibility
PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote
More informationPathfinder Air-Cooled Single-Screw Chiller/Heat Pump
Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:
More informationMembrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification
Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting
More informationCKD refrigerating type dryer
CKD refrigerating type dryer GT9000 Applicable air compressor: 90, 120, 1, 190, 240, 300, 380, 4, 710, 960kW Components for air preparation and pressure adjustment / main line unit / refrigerating type
More informationRefrigerated Compressed Air Dryer
Manual Instruction for Refrigerated Compressed Air Dryer Warning: Place the dryer machine horizontal. Never upside down Dino-power Industry & Trade Co., Ltd www.aircompressorschina.com Dino-power 1 PREPARED
More informationAOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO
AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION
More informationEBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationMEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,
More informationAMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications
Water Separator Series The series water separator is installed on the air pressure line to remove water drops in the compressed air. It is suitable for use in cases where "water must be removed, but the
More informationOwner s Manual Refrigerated Compressed Air Dryers Model F-100
Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
More informationRefrigeration air dryer
Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air
More informationEBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an
More informationOwners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer
1 Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer DESCRIPTION PAGE INTRODUCTION 2 INSTALLATION 3 INSTALLATION GUIDE 4 DRYER CONTROLS 5 DRYER CONTROLS AND SAFTEY SHUTDOWNS 6 START UP 6 INITIAL
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350
Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationTechnical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.
anfoss HP-H xtra and hotter hot water. xtra large integrated hot water tank. an reduce heating costs by more than 50 percent. Main parts.......................................................................
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com
More informationPrinted 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS
Printed 2000, replaces all previous editions Kyl M (98) PK.523 PK.5231 PK.5232 OOLIN UNITS OR LIMT ONTROL, OMMRIL RRIRTION N INUSTRIL PPLITIONS Swedish cooling units. Mini, Mid The rigadon range of commercial
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532
Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationPURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)
PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm
More informationFeaturing Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut
Featuring Ozone-safe HFC134a Hitachi Centrifugal Chillers NEW GXG-S Series GSG-S Series Debut Centrifugal Chiller New GXG-S, GSG-S Series Debut High-efficiency New series Centrifugal Chillers that use
More informationDrain Separator for Vacuum
Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min
More informationSECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS
PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED
More informationEBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More informationCoolPro. Compressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency.
oolpro ompressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency. The ftercooler market has gone through a profound change in recent
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING
More informationVRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT
Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationSplit-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English
Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationOperation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.
Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause
More informationManual Desiccant Dryer Numbering System
atalog 9M-TK-90-3 esiccant ryer ing System Manual esiccant ryer ing System Unit Thread Pipe unction amily Type Size Options Options Options X 0 6 0 2 0 0 0 Unit unction amily Thread Type Options X Manual
More informationPrevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK
Moisture Control Tube Prevents! Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! vapor Moisture control tube vapor All you have to do
More informationOwners Manual Refrigerated Air Dryer MHT SERIES
Owners Manual Refrigerated Air Dryer MHT SERIES IMPORTANT: READ THIS MANUAL CAREFULLY. IT CONTAINS IN- FORMATION ABOUT SAFETY AND THE SAFETY OF OTHERS. ALSO BECOME FAMILAR WITH THE PROPER INSTALLATION
More informationCost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.
Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate
More informationPersonalized comfort for offices and shopping malls RANGE OPERATING LIMITS
R-c Personalized comfort for offices and shopping malls iscreet solution in centralized facilities with closed water loop asy installation in false ceiling T-XH-5-I-I SRIPTION Heat Pumps and ooling Units
More informationTUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features 197 Safety Precautions 199 Secondary Air Flow Rate, Secondary Air Dew Point, and Pressure Drop 201
More informationSAFETY AND OPERATING MANUAL
SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.
More informationPORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.
PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the
More informationREFRIGERANT ON-VEHICLE INSPECTION AC 14
14 REFRIGERANT ON-VEHICLE INSPECTION 1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET (a) This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632
More informationTechnical data DHP-R. A brine-to-water building heat pump in power outputs
brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3
More informationPAC-AH10A-G. Air Handling Unit Controller INSTALLATION MANUAL FOR INSTALLER
ir Handling Unit ontroller P-H10- OR NSTLLR NSTLLTON MNUL or safe and correct use, please read this installation manual thoroughly before installing the controller. 2 [ig. 2.0.1] 1 2 3 4 5 6 7 1 ontroller
More information13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC
Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624
More informationCPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 Registered in England and Wales No. 05058855 VAT VERSION
More informationEC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons
E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any
More informationPressure Switches Precautions 1 Be sure to read this before handling.
Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate
More informationRefrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm
Refrigerated Air Dryers VF Series Non-Cycling 10-2,000 scfm DHT Series Front High Inlet Page Temperature 20-125 scfm 1 VF Series Non-Cycling Refrigerated Air Dryer 10-2,000 scfm Since 1994, Aircel has
More informationSCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series
10 3000 SCFM REFRIGERATED COMPRESSED AIR DRYERS CRN Series Durability Delivered Champion CRN Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering
More informationNON-CYCLING REFRIGERATED AIR DRYERS. RNC Series
NON-CYCLING REFRIGERATED AIR DRYERS RNC Series Durability Delivered Gardner Denver RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering
More informationWater Circulator (Chiller) & Cold Trap
Yamato Scientific America Innovating Science for Over 125 Years Water Circulator (Chiller) & Cold Trap Contents Water Circulator (Chiller) Cold Trap CA Series Page Page 91 93 9 Water Circulator (Chiller)
More informationInstruction Manual. Refrigerated Air Dryer
January 2008 Edition Carefully read this manual before attempting to operate or perform maintenance on this equipment. Instruction Manual Of Refrigerated Air Dryer Hangzhou Kelin Aier Qiyuan Equipment
More informationSplit-type Air-Conditioner
Split-type Air-Conditioner MXZ-2D52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of
More informationDesiccant Dehumidifier
Since the 1950s Desiccant Dehumidifier Dry Spaces With NO Added Heat BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM Product Description
More informationMoisture Control Tube
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) -80 www.cmafh.com Moisture Control Tube (Moiscon) Prevents! Prevents condensation in piping for small cylinders/air
More informationEBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL KOMPACT OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Kompact is a rugged, industrial unit, which utilizes
More informationEBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com
More informationRNC Series SCFM Global Air Treatment
RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability
More informationOwner s Manual Refrigerated Compressed Air Dryer Model F-50
Owner s Manual Refrigerated Compressed Air Dryer Model F-50 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationFDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)
OPERA TION & I NSTALLAT I O N FDT11 FDT15 FDT18 MANUAL DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed) Read this operating & installation instruction carefully and keep it for future reference DUCTED
More informationEBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD60 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the CD60 dehumidifier is a rugged, industrial unit which utilizes
More informationOPERATING MANUAL MODEL AIR 1500TM AIR DRYER
OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...
More informationMODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS
MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a
More informationFUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS
FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS The Most Advanced Technologies for High-Quality air High-precision processing technology is required to produce the components that make up a Scroll Compressor.
More informationPrevents condensation
Moisture Control Tube Prevents condensation in piping for small cylinders/air grippers. Diffuses water vapor in the piping to the outside! Water vapor Linear shape Suitable for applications where cylinders
More informationMOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB
MOBILE AIR CONDITIONER User Manual PC15/20/26-BCB VERY IMPORTANT Please read this instruction guide before install and using your mini portable type air conditioner unit. This instruction manual is the
More informationSUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU. 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor.
ASH218SV-C8LU SUBJECT Model ASH218SV-C8LU SPECIFICATION ASH218SV-C8LU PAGE:1/23 1. SCOPE This specification is applied to SHANGHAI HITACHI rotary compressor. 2. SPECIFICATION OF COMPRESSOR 2.1 Model ASH218SV-C8LU
More informationHigh Performance Air to Water Heat Pump
High Performance ir to Water Pump ir to Water Pump Hz 10HM01E0 ir to Water Pump Mitsubishi Heavy Industries has integration of high technology in a variety of areas and provides comprehensive solutions
More informationHX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX
HX Series Compressed Air Dryers 10 to 2400 scfm Setting a new standard in Quality and Reliability ELIMINATE WATER FROM YOUR COMPRESSED AIR SYSTEM Untreated compressed air is the unseen killer in all compressed
More informationHigh Performance Air to Water Heat Pump
R410 20 High Performance ir to Water Pump ir to Water Pump Hz HM01E ir to Water Pump Mitsubishi Heavy Industries has integration of high technology in a variety of areas and provides comprehensive solutions
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationCNC Series Refrigerated Air Dryer CFM
CNC Series Refrigerated Air Dryer 10 3000 CFM NEW Engineered to Save CNC Value CompAir leads the way in providing value to our customers We looked beyond the typical refrigerated air dryer and designed
More informationInstallation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E
EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this
More informationEBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL NEPTUNE OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Neptune dehumidifier is a super high capacity industrial
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet
More informationTHF Series Industrial High Efficiency Filters
www.titusfilters.com TH Series Industrial High fficiency ilters and Save energy dollars protect your air system The ompressed ir hallenge, a government/ industry sponsored energy savings awareness program,
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationCD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 8 Product Support Questions: Contact Ebac USA at (757) 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit
More information