Product Catalog VALVES
|
|
- Donna Shepherd
- 5 years ago
- Views:
Transcription
1 SUIKA CLIMATE Product Catalog VALVES CONTACT WEB ADDRESS Fremont, CA, TELEPHONE +1 (800) (510)
2 Suika Climate Toeflex ABOUT US Suika Climate (US), Toeflex (non-us) is a well-established distributor and manufacturer specializing in HVAC-R components and customized end-toend solutions (commercial heat pumps, drying equipment etc.). Originally founded in South Africa in 1996, we have been headquartered in Chengdu, China since Starting as a supplier of refrigeration components for the local market, we have expanded into over 30 countries and are today internationally competitive in both commercial and residential HVAC-R applications. Our catalog of products are of high quality, follow key international standards and have necessary approvals and certifications. We pride ourselves in fast, clear and effective communication and believe in building a long-term relationships with customers that are mutually beneficial. We have served customers of all sizes and maintained decade long relationships with many of them. We sincerely appreciate the opportunity to serve you and hope to hear from you!
3 01 02 Solenoid Valve TXV PAGE 1-6 PAGE eev 04 4-Way Reversing Valve PAGE PAGE Ball Valve 06 Check Valve PAGE PAGE Charge Valve PAGE Service Valve PAGE 38-41
4 SOLENOID VALVE FDF SERIES (ANGLED) Application FDF Series solenoid valves are direct operated or pilot operated solenoid valves. They are mainly used in refrigerant control of various appliances such as refrigerating and freezing systems, air conditioners and heat pumps Features Specifications Low energy consumption Fully surrounded coil bracket, good operating performance and low temperature rise Great valve opening performance, high MOPD Highly reliable hard seal structure Applicable for various types of refrigerants Applicable for all common HCFC and HFC refrigerants such as: R22, R134a, R404A, R407C, R410A, R507A Fluid temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 50 C / -22 to 122 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Insulation class: B Approvals: declaration according to PED or LVD, UL, and VDE Coil Parameters Model Code No. Voltage Frequency Power Voltage V Hz W Tolerance Insulation Class Enclosure Connection FDFX AC 85% to 110% FDFX AC 85% to 110% FDFX AC 50/60 7W / 5W 85% to 110% B IP54 Cable FDFX AC 85% to 110% FDFX AC 85% to 110% Note: Wire terminal, sheath, and length can be customized according to customer s requirement
5 Coil Please check our website for Coil Dimension Nominal Capacity Model R22 R134a R404a /R507 Capacity in [kw] Liquid Line Suction Gas Hot Gas R407C R410A R22 R134a R404a /R507 R407C R410A R22 R134a R404a /R507 R407C FDF2KA FDF2A FDF2.2A FDF2.5A FDF6A R410A Valve Body Technical Parameters Model Version Actuation Port Size Flow Rate MOP Max OPD Min Connection Ød FDF2KA-002 Normally Opened mm inch m3/h gpm mpa psi mpa psi mpa psi mm inch /4 FDF2A-010 Direct /4 - FDF2.2A-010 Normally /4 652 FDF2.5A-010 Closed /4 FDF6A-010 Pilot /16
6 Style and Dimensions Dimensions Model Code No. Style E D A B G F mm inch mm inch mm inch mm inch mm inch mm inch FDF2KA B FDF2A A FDF2.2A A FDF2.5A A FDF6A A
7 SOLENOID VALVE FDF SERIES (STRAIGHT) Application Features FDF Series solenoid valves are mainly used in refrigerant control of various appliances such as refrigerating and freezing systems, air conditioners and heat pumps Specifications Applicable in liquid, suction and hot gas pipe lines Available in various AC and DC electromagnetic valve coils Low energy consumption Great valve opening performance, high MOPD Special seal gasket Normally closed Applicable for all common HCFC and HFC refrigerants: R22, R134a, R404A, R407C, R410A, R507A Fluid temp range (C & F): -30 to 105 C / -22 to 221 F Ambient temp range: -40 to 55 C / -40 to 131 F Relative humidity: 0 to 95% RH Approvals: CQC, TUV, declaration according to LVD or PED Coil Parameters Model Code No. Voltage Frequency Voltage V Hz Tolerance FDFXQ AC 50/60 85% to 110% FDFXQ AC 50/60 85% to 110% FDFXQ AC 50/60 85% to 110% FDFXQ DC - 95% to 105% Insulation Class F Enclosure IP65 Connection FDFXQ DC - 95% to 105% FDFXQ AC 50/60 85% to 110% Cable with 0.15m DIN
8 Nominal Capacity Model R22 R134a R404a /R507 Capacity in [kw] Liquid Line Suction Gas Hot Gas R407C R410A R22 R134a R404a /R507 R407C R410A R22 R134a R404a /R507 FDF FDF FDF FDF FDF FDF FDF FDF FDF FDF R407C R410A (1) The working condition of liquid and suction gas rated cooling capacity: Evaporating Temp. Te=-10 C ; Liquid Temp. Before Valve: Tl=25 C ; Pressure Drop After The Valve ΔP=0.015 MPa. (2) The working condition of hot gas rated cooling capacity: Condensing Temp. Tc=40 C ; Pressure Drop Across The Valve ΔP=0.08 MPa; Hot Gas Temp. Th=65 C ; Subcooling ΔTsc=4K Please check our website for more detailed capacity and ordering information Valve Body Technical Parameters Model Flow Factor Kv (2) MOP (1) MOPD for liquid medium is about 0.1 MPa lower. (2) The Kv value is the water flow at a differential pressure of 0.1 MPa. Flow Unit: m3/h; Density: 1000 kg/m3. OPD Max. Pressure Difference [mpa] (1) (Gas) Max. Pressure Difference [psi] OPD Min Weight m3/h mpa psi AC DC AC DC mpa psi Kg Pound FDF FDF FDF FDF FDF FDF FDF FDF FDF FDF
9 Styles Note: Please check our website for dimension details
10 THERMOSTATIC EXPANSION VALVE TA/TAE SERIES Application TA/TAE Series thermostatic expansion valves are used to adjust flow of refrigerant into the evaporator of smaller capacity refrigerations, heat pumps and air conditioning systems. The valve operates by controlling the refrigerant s superheat at the outlet of the evaporator. Features Specifications Supplied with both fixed and adjustable superheat setting Available with filter in the inlet tube Versions with and without external equalization, with and without bleed and with and without MOP Wide vaporizing temperature range Applicable refrigerants: R134a, R404A, R407C, R507A and R290 Max. bulb temperature: 120 C / 248 F Max. valve housing temerature: 150 C / 302 F Max. working pressure: 3.4 mpa / 493 psi Max. test pressure: 3.75 mpa / 544 psi Equalization connection: 6mm or 1/4 inch (solder ODF) Capillary tube length: 0.75m (30 inch) BP: 15% / 30% Approvals: UL, CE Standard and MOP Valves Evaporating Temperature Refrigerant -40 to 10 C -25 to 10 C -25 to 15 C -25 to 20 C Without MOP MOP 15 C MOP 20 C MOP 25 C R134a - 58 psig/ 5 bar 70 psig / 5.8 bar 83 psig / 6.7 bar R404A psig / 9.3 bar 140 psig / 10.7 bar 168 psig / 12.6 bar R psig / 7.4 bar 109 psig / 8.5 bar 123 psig / 9.5 bar R407C psig / 9 bar 136 psig / 10.4 bar 158 psig / 11.9 bar
11 Nominal Capacity Model R134a R407C R404A/R507C R290 TR kw TR kw TR kw TR kw TA/TAE TA/TAE TA/TAE TA/TAE TA/TAE TA/TAE TA/TAE TA/TAE The rated capacity is based on : 1. Evaporating Temperature Te=5 C ; 2. Liquid Temperature Tl=28 C; 3. Static Superheat SS=4K; 4. Opening Superheat OS=4K. Please check our website for more detail capacities Identification Example TAN/TAEN = Type(N=R134a,E=External Pressure Equalization) 0.78TR = Rated Capacity in Tons 2.7kW = Rated Capacity in kw R134a = Refrigerant MOP 20 = Max. Operation Pressure -25 ~15 C = Evaporating Temperature Range PS 34 bar = Max. Working Pressure BP 15 = Bleed 15% = Code Number BC = Date Marking Refrigerant R407C = Z R134a = N R404A/R507 = S R290 = P
12 Dimensions and Weight Angleway Non-Adjustable Size Weight Approx.: 0.19 kg Straightway Adjustable Size Weight Approx.: 0.22kg Note: Please check our website for ordering details
13 THERMOSTATIC EXPANSION VALVE TI/TIE SERIES Application TI/TIE series are used to control liquid flow into evaporators by sensing the refrigerant temperature at the evaporator outlet, where the bulb must be placed. This series is targeted for heat pumps, ice machines and beverage machines. Features Specifications Supplied with MOP (MOP15 C, MOP20 C) Interchangeable orifice assembly makes it easy to match capacity and storage For biflow systems, please contact us Applicable refrigerants: R134a, R404A, R407C, R507A Max. temperature: Bulb, when valve is installed: 100 C / 212 F Bulb, element not mounted: 60 C / 140 F Max. working pressure: 4.6 mpa / 667 psi Max. test pressure: 5.1 mpa / 740 psi Approvals: UL, CE Standard and MOP Valves Evaporating Temperature Refrigerant -40 to 10 C -40 to -5 C -40 to -15 C -60 to -25 C MOP 15 C MOP 0 C MOP -10 C MOP -20 C R404A/R bar 5.2 bar 3.4 bar 2.1 bar R407C 6.6 bar R134a 3.8 bar 2.1 bar 1.0 bar - R410A 11.5 bar - - -
14 Orifice Assembly With Filter Nominal Capacity [TR] Nominal Capacity [kw] Orifice NO. R404A R404A R407C R134a R410A R407C R134a R410A R507 R507 Code NO. 0x The rated capacity is based on: 1. Evaporating Temperature Te=4.4 C ; 2. Refrigerant Temperature Ahead of Valve Tl=37 C ; 3. Condensing Temperature Tc=38 C ; Please check our website for more detail capacities and instructions of selecting valve Identification TIES = Model (S: R404A) R404A = Refrigerant -40~+10 = Evaporation Temperature( C) MOP15 C = Max. Operation Pressure PS 46 bar = Max. Working Pressure = Code Number Refrigerant BC = Date Marking R407C = Z Inlet/Outlet Connections Flare Flare / Flare Solder Refrigerant R407C R134a R404A/R507 R410A Pressure Equalization Internal External Internal External Internal External Internal External R134a = N R404A/R507 = S R410A = L Capillary Tube Connection Inlet x Outlet [m] [in. in.] [mm mm] 1.5 3/8 1/
15 Dimensions Note: Please check our website for dimension details Please click here for ordering detail
16 THERMOSTATIC EXPANSION VALVE TC SERIES Application TC series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant s superheat at the outlet of the evaporator. They can be used with various refrigerants under all working conditions. Typical applications are refrigeration systems such as freezers, ice makers, dehumidifiers, air conditioners and heat pumps at various evaporation temperature ranges. Features Specifications Straight way design Bi-directional design; balance port design Adjustable superheat MOP function(mop15 C) BP function Installation and collection types: ODF, Flare, MIO and ORFS Applicable refrigerants: R134a, R404A, R407C, R410A and R507a Max. sensor bulb temperature: 120 C / 248 F Max. valve body temerature: 150 C / 302 F Max. working pressure: 4.6 mpa / 667psi Max. test pressure: 5.1 mpa / 740 psi External balance connection: 1/4 in. / 6 mm (ODF welding) Capillary tube length: 1.5 m or 59 inch BP: 15% Approvals: UL, CE Standard and MOP Valves Evaporating Temperature Refrigerant -40 to 10 C -25 to 10 C Without MOP MOP 15 C R134a - 55 psig/ 5 bar R404A/R psig / 9.4 bar R407C - 95 psig / 7.5 bar R410A psig / 12.5 bar
17 Nominal Capacity Model TCE TCBE Orifice R134a R404A/R507 R407C R410A NO. TR kw TR kw TR kw TR kw The rated capacity is based on: 1. Evaporating Temperature Te=5 C ; 2. Liquid Temperature Before Valve Tl=28 C ; 3. Condensing Temperature Tc=32 C ; 4. Static Superheat SS=4K; 5. Opening Superheat OS=4K. Please check our website for more detail capacities Identification Example TCEN = Valve Type (N-R134a) 4.5TR = Nominal Cooling Capacity in Tons 17kW = Nominal Cooling Capacity in kw R134a = Refrigerant -25~+10 C = Evaporating Temperature Range( C) MOP15 C = Max. Evaporating Pressure PS 46 bar = Max. Working Pressure = Code NO. BC = Date Marking. Connection Size Model TCE TCBE Connection Sizes Inlet Outlet ODF Welding Refrigerant R407C R134a R404A/R507 R410A = Z = N = S = L Capillary Lengths mm inch m 10х16 3/8х5/8 12х16 1/2х5/8 12х22 1/2х7/ х22 5/8х7/8 16х28 5/8х9/8 16х22 5/8х7/8 16х28 5/8х9/8 22х28 7/8х9/ х35 7/8х11/8
18 Dimensions Please check our website for ordering details Click here for more dimension details
19 THERMOSTATIC EXPANSION VALVE TCCE SERIES Application TCCE thermostatic expansion valves are used to regulate refrigerant flow into evaporators, especially in applications such as residential air conditioning systems, split systems, roof top units, heat pumps, light commercial air conditioning systems and chillers. Features Specifications Compact size - hermetic design Versions with and without check valve For product with BP function or special installation, please contact us Various installation modes (Flare, Solder, MIO, ORFS) Applicable for all common HCFC and HFC refrigerants such as: R32, R290, R134a, R404A, R407C, R410A and R507A Max. bulb temperature: R407C: 100 C or 212 F R410A: 75 C or 167 F Max. valve body temerature: 110 C / 230 F Max. working pressure: 4.6 mpa / 667psi Max. test pressure: 5.1 mpa / 740 psi Options for connections: ODF(3/8, 1/2, 5/8), ODM, etc. Equalization: 1/4 in. (ODF) 1/8 in. (ODF/ODM) Capillary tube length: 800mm or 31 inch Approvals: UL, CE
20 Nominal Capacity Orifice R134a R407C R404A/R507C R410A R290 R32 NO. TR kw TR kw TR kw TR kw TR kw TR kw The rated capacity is based on: 1. Evaporating Temperature Te=5 C ; 2. Liquid Temperature Before Valve Tl=28 C ; 3. Condensing Temperature Tc=32 C ; 4. Opening Superheat OS=4K. Please check our website for more capacities and ordering detail Check Valve Capacity Mass Flow lb/h ΔP (psi) Identification TCCEL = Valve Type (L:R410A) 2TR = Rated Capacity in Tons 7kW = Rated Capacity in kw R410A = Refrigerant -25~+20 C = Evaporating Temperature Range = Code NO. PS 46 bar = Max. Working Pressure BP 15 = Bleed 15% BB = Date Marking Refrigerant R407C R410A R134a R404A/R507 R290 R32 = Z = L = N = S = P = D
21 Inlet/Outlet Connections Options for Connections (In Out Equ) 3/8 3/8 1/4 ODF 3/8 3/8 1/8 ODF 3/8 1/2 1/4 ODF 3/8 1/2 1/8 ODF 1/2 1/2 1/4 ODF 1/2 1/2 1/8 ODF 1/2 5/8 1/4 ODF 1/2 5/8 1/8 ODF 3/8(OEM1) 5/8(Aeroquip) 1/8(635mm) 3/8(OEM2) 5/8(Aeroquip) 1/8(635mm) 5/8(Chatleff) 5/8(Aeroquip) 1/8(635mm) 5/8(Chatleff) 5/8(Aeroquip) 7/16(nut) 3/8(ODF) 5/8(Aeroquip) 1/8(635mm) 3/8(ODF) 5/8(Aeroquip) 7/16(nut) 3/4(Chatleff) 3/4(Aeroquip) 1/8(635mm) 3/4(Chatleff) 3/4(Aeroquip) 7/16(nut) Note: supply both with Check Valve and without Check Valve Dimensions Non-Adjustable
22 Adjustable
23 ELECTRONIC EXPANSION VALVE DPF(B) SERIES Application DPF(B) Series electronic expansion valves are designed for use in air conditioning and refrigeration systems, or in heat pumps. The valve controls the automatic adjustment of refrigerant flow rate to allow the system to work under optimized conditions (thus fast cooling or heating, precise temperature control and energy saving). The valve can also be used for suction line pressure controls. These valves provide bi-directional operation to control the refrigerant flow rate in heating or cooling mode. Features Specifications Low noise and high control precision Bi-directional flow Low power consumption and wide flow regulation range Superior self-lubricating thread Plastic packaging with anti-corrosion coil Advanced and highly reliable welding Good actuating performance Compact and light Applicable for all common HCFC and HFC refrigerants: R22, R32, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 70 C / -22 to 158 F (duty cycle rate below 50%) Ambient temp range: -30 to 60 C / -22 to 140 F (duty cycle rate below 50%) Relative humidity: 0 to 95% RH Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Medium flow direction: Bi-directional Life cycle: 100,000 Approvals: declaration according to PED or LVD, UL, and VDE Coil Parameters Item Parameter Full Stroke 500 pulses Opening Pulse 30±20 Rated Voltage DC12V±10%, rectangular wave Actuating Mode 4-phase 8-step permanent magnet Excitation Mode 1 to 2phase excitation Excitation Rate 30 to 40 PPS Insulation Class E Resistance 46±3.7Ω(Φ1.3~Φ2.4), 36±3.4Ω(Φ2.8~Φ3.2) (20 C) Current 260mA/phase(Φ1.3~Φ2.4), 330mA/phase(Φ2.8~Φ3.2) (20 C) Protection Class IP65
24 Nominal Capacity Model Orifice R22 R32 R134a R404A R407C R410A mm inch TR kw TR kw TR kw TR kw TR kw TR kw DPF(B)1.3C DPF(B)1.65C DPF(B)1.8C DPF(B)2.0C DPF(B)2.2C DPF(B)2.4C DPF(B)2.8C DPF(B)3.0C DPF(B)3.2C The rated capacity is based on: 1. Full-Open; 2. Condensing Temperature Tc=38 C ; 3. Evaporating Temperature Te=5 C ; 4. Superheat Degree ΔTsh=0K; 5. Subcooling Degree ΔTsc=0K Note: For full list of model variants and selection please see our selection table Flow Rate Flow Type 1 Flow Type 2 Test Condition: 0.1mpa / 15psi
25 Style and Dimensions DPF(B) Model Φ1.3 to Φ2.4 Φ2.8 to Φ3.2 A B C D Style mm inch mm inch mm inch mm inch A /4 B A /16 B Coil Model Code NO. Valve Model Wire Length mm inch Wire Number Connector DPFX Φ1.3 to Φ wires XHP-5 DPFX Φ1.3 to Φ wires XHP-6 DPFX Φ2.8 to Φ wires XHP-5 DPFX Φ2.8 to Φ wires XHP-6
26 4-WAY REVERSING VALVE DSF/DSF(S) SERIES Application DSF/DSF(S) series four-way reversing valves are applicable for heat pump systems such as central, unitary and room air conditioners. The valve allows the system to switch between cooling mode and heating mode by changing the flow path of refrigerant Features Specifications Thermoset material molded electromagnetic coil, better water resistance, greater electric strength and reliable insulation Less temperature rise, lower noise and higher vibration resistance Better sealing performance, higher efficiency and lighter weight Applicable refrigerants such as: R22, R32, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 70 C / -22 to 158 F Relative humidity: 0 to 95% RH Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Approvals: PED, LVD, VDE, TUV and UL Coil Parameters Model Code No. Rated Voltage Frequency Rated Power Temperature Rise of Rated Voltage Max. Working Temperature Insulation Class Enclosure Connection Type Supply Length V Hz W K C / F mm inch DXQ-242-ND AC24 50/ < 80 Spade - - DXQ AC100 50/ < DXQ AC200 50/ < 80 AC DXQ AC / < DXQ AC / < C / 266 F B IP Wire DXQ DC35-9 < 80 DC DXQ AC100 50/60 18 < DXQ AC200 50/60 18 < 75 Bi-stable Coil DXQ DC <
27 Coil Styles Note: Please check our website for dimension details
28 Nominal Capacity Capacity Pressure Drop P [bar] Model R134a R404A R407C R410A Cond.1 Cond. 2 Cond. 1 Cond. 2 Cond. 1 Cond. 2 Cond. 1 Cond kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw DSF DSF DSF-9B DSF-9C DSF-9E DSF DSF-11B DSF-11E DSF-11I DSF DSF-34D DSF-34H DSF DSF DSF DSF-70B DSF DSF-105D DSF DSF DSF Note: 1. Cond.1: Tc=38 C, Te=5 C, ΔT sh =5K, ΔT sc =0K; 2. Cond.2: Tc=54.4 C, Te=7.2 C, ΔT sh =5K, ΔT sc =5K. Valve Body Technical Parameters Stainless Steel DSF(S) Series Model Port Size Kv Flow Factor Cv Flow Factor Connections ODF OPD ØD ØE/S/C Max Min mm inch m3/h gpm mm inch mm inch mpa psi mpa psi DSF(S) / /8 3.1 (R410A, R32) 2.45 (R134a, R407C, R404A) 450 (R410A, R32) 355 (R134a, R407C, R404A) DSF(S) / /
29 Brass DSF Series Model Port Size Kv Flow Factor Cv Flow Factor Connections ODF OPD ØD ØE/S/C Max Min mm inch m3/h gpm mm inch mm inch mpa psi mpa psi DSF / /8 DSF / /2 DSF-9B / /8 DSF-9C / /8 DSF-9E / /2 DSF / /8 DSF-11B / /8 DSF-11E / /8 DSF-11I / /4 DSF / /4 DSF-34D / /8 DSF-34H / /8 DSF / /8 DSF / /8 DSF /4 DSF-70B / /8 DSF / /2 DSF-105D / /8 DSF /2 45 7/4 DSF / /8 DSF /8 3.1 (R410A, R32) 2.45 (R134a, R407C, R404A) 450 (R410A, R32) 355 (R134a, R407C, R404A) Styles
30 Note: Please check our website for dimension details
31 LARGE CAPACITY 4-WAY REVERSING VALVE DRVB SERIES Application DRVB series switches the mode between cooling and heating by changing the refrigerant flow path. The flow path inside the DRVB is controlled by a pilot 4-way valve, which alters the pressure difference between two side seal chambers of the valve body Features Specifications X-cross flow path design ensures high capacity, short flow path and low pressure drop A small capacity 4-way reversing valve as a pilot valve ensures stability and reliability Flange construction makes assembly and maintenance easy Built-in self-lubricating bushing provides over 100,000 cycles of shifting service life Special material seal ring allow the valve to be used with all common refrigerants Applicable refrigerants such as: R22, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 130 C / -22 to 266 F Ambient temp. range: -20 to 55 C / -4 to 131 F Relative humidity: 0 to 95% RH Max. working pressure: 4.2 mpa / 609 psi Max. working pressure differential: 3.1 mpa / 450 psi Min. working pressure differential: 0.3 to 0.4 mpa / 44 to 58 psi Approvals: declaration according to PED or LVD Coil Specifications Ambient temp. range: -30 to 55 C / -22 to 131 F Allowable voltage tolerance: 85% to 110% Standard coil: 220V AC Relative humidity: 0 to 95% RH
32 Nominal Capacity Model R22 R134a R407C R410A TR kw TR kw TR kw TR kw DRVB115* DRVB118* DRVB121* DRVB125* DRVB130* The rated capacity is based on: 1. Condensing Temperature Tc=50 C; 2. Liquid Temperature Before Expansion Valve TI=48 C ; 3. Evaporating Temperature Te=2 C ; 4. Suction Gas Superheat Degree T sh =6K; 5. Low Pressure Drop P=0.015 MPa. Note: For full list of model variants and capacities please see our model capacity chart Styles Note: Please check our website for dimension details
33 BALL VALVE FQ SERIES Application FQ series Ball Valve is applicable for commercial air conditioner, freezing or deep-freezing equipment or other refrigeration circuits. The valve opens and closes inner flow path through the valve stem. Access port variant can also be supplied Features Specifications Straightway type, low pressure drop, cost-effective Valve body and valve seat with welded structure increasing reliability Modified polymer to ensure fitting tightness Small installation space required Supplied with/without access port, with holes for panel mounting Applicable refrigerants such as: R22, R134a, R404A, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -20 to 60 C / -4 to 140 F Relative humidity: 0 to 95% RH Max. working pressure: 4.5 mpa / 653 psi Approvals: UL, declaration according to PED Valve Body Technical Parameters Without Access Port ODF Connection Flow Rate (1) Model Port Size Port Size Code NO. [inch] [mm] Code NO. m3/h gpm FQ 06 1/ FQ 10 3/ FQ 12 1/ FQ 16 5/ FQ 19 3/ FQ 22 7/ FQ 28 9/ FQ 35 11/ FQ 42 13/ FQ 54 17/ FQ 67 21/ FQ 79 25/ (1) CFD (computational fluid dynamics) calculated values.
34 With Access Port Model Port Size [inch] Code NO. ODF Connection Flow Rate (1) Port Size [mm] Code NO. m3/h gpm FQ 10 3/ FQ 12 1/ FQ 16 5/ FQ 19 3/ FQ 22 7/ FQ 28 9/ FQ 35 11/ FQ 42 13/ FQ 54 17/ FQ 67 21/ FQ 79 25/ (1) CFD (computational fluid dynamics) calculated values. Dimensions Note: Please check our website for dimension details
35 CHECK VALVE FDM SERIES Application FDM series check valves use magnetic diaphragm design with metal sealing structure, built-in guiding device, and self-closing structure. The valve can be installed in any angle Features Specifications Self-closing structure allows for any installation angle Low internal leakage Applicable refrigerants such as: R22, R134a, R404a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Approvals: UL, declaration according to PED Valve Body Technical Parameters
36 Model FDM 0702 FDM 0703 FDM 0904 FDM 0905 FDM 0906 FDM 0907 FDM 1107 FDM 1406 FDM 1409 FDM 1709 FDM 2111 FDM 2113 FDM 2817 FDM 3321 FDM 3325 Code NO. Connection Size C L L1 Max. Working Pressure Pressure Drop Across Valve P Flow Rate inch mm inch mm inch mm inch mpa psi mpa psi m3/h gpm / / / / / / / / / / / / / / /
37 CHECK VALVE FD SERIES Application FD series check valve is used in residential air conditioning system to ensure one-way flow of liquid Features Specifications Integrated structure reduces leakage risk Very low pressure drop Applicable refrigerants such as: R134a, R404a, R407C, R410A, and R290 Medium temp range (C & F): -30 to 120 C / -22 to 248 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Approvals: UL, declaration according to PED Valve Body Technical Parameters Model Code NO. Style Dw L D Dm H d dn h Min. OPD Kv Cv mm mm mm mm mm mm mm mm mpa psi m3/h gpm FD A FD A FD- 0070/A A FD B FD B FD C FD B
38 Styles
39 CHARGE VALVE FJT SERIES Application Charge valves are mainly installed in air conditioning and refrigeration systems. They are used as service valves for circuit evacuation to vacuum and for refrigerant injection Features Simple structure, convenient to use Combination of soft seal and hard seal ensures airtightness Specifications Applicable refrigerants such as: R32, R134a, R404a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 70 C / -22 to 158 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Approvals: UL, declaration according to PED
40 Dimensions Model Code NO. Connections FJT-8881-DG /4 FJT-8883-DG /4 Dimensions Solder ODF φd Flare A B φc E mm inch inch mm inch mm inch mm inch 1/2-20 UNF 7/16-20 UNF Applicable Refrigerant R32, R410A R407C, R134a, R404A Model FJT DG4 FJT DG4 Code NO. Connections / /4 Dimensions Solder ODF φd Flare A B D mm inch inch mm inch mm inch 1/2-20 UNF 7/16-20 UNF Applicable Refrigerant R32, R410A R407C, R134a, R404A
41 SERVICE VALVE FJ SERIES Application The FJ service valves main functions are: 1) connect air condition indoor unit and outdoor unit; 2) open or close the refrigerant system; 3) vacuumize or charge the refrigerant into the system Features Specifications Simple structure, convenient to use Combination of soft seal and hard seal ensures airtightness Applicable refrigerants such as: R32, R134a, R404a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -30 to 70 C / -22 to 158 F Max. working pressure: 4.2 to 4.5 mpa / 609 to 653 psi Relative humidity: 0 to 95% RH Approvals: UL, declaration according to PED Nominal Capacity Model Code NO. Capacity TR kw FJ-8888-DG FJ-8888-DG FJ-8888-DG FJ-8888-DG FJ-8888-DG FJ-8887-DG FJ-8887-DG FJ-8887-DG FJ-8887-DG FJ-8887-DG Applicable Refrigerant R410A, R32 R407C, R134a, R404A
42 Dimensions Note: Please check our website for dimension details
43 SERVICE VALVE FJB SERIES Application The FJB series service valves are used in VRF air conditioning system. The main functions are: 1) connect air condition indoor unit and outdoor unit; 2) open or close the refrigerant system; 3) vacuumize or charge the refrigerant into the system Features Specifications Double sealing design ensures low leakage Good sealing performance and long lifetime Reliable design Applicable refrigerants such as: R22, R134a, R407C, R410A Medium temp range (C & F): -30 to 120 C / -22 to 248 F Ambient temp range: -20 to 60 C / -4 to 140 F Max. working pressure: 4.2 mpa / 609 psi Approvals: declaration according to PED
44 Styles Dimensions Note: Please check our website for dimension details
MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valves, type REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3
More informationThermostatic Expansion Valves Type TR 6
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic Expansion Valves Introduction The series is a hermetic tight design, designed and developed with features especially for use in applications such as:
More informationCapacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationThermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostatic Expansion valves, type A/AE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range... Technical
More informationFlexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55
MAKING MODERN LIVING POSSIBLE Upgrade and service with ease Extend lifetime with modular design Thermostatic expansion valves Type TE5-55 Flexible Upgrade with backward compatible valve technology. Mix
More informationHot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)
Data sheet Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory) CPCE hot gas bypass regulator adapt compressor capacity to actual evaporator load. They are designed for installation
More informationCapacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction CPCE capacity regulators adapt compressor capacity to actual evaporator load. They are designed for
More informationPULSE WIDTH MODULATING VALVES
PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES MODEL HP P4144 MODELS CS & DS P4145 Features Long life (100 million cycles). Suitable for all common refrigerants except ammonia. Maximum
More informationCheck valve Types NRV and NRVH
Check valve s NRV and NRVH NRV and NRVH can be used in liquid. suction and hot gas lines in refrigeration and air conditioning plant with HCFC. HFC and HC flammable refrigerants. The valves ensure the
More informationMAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION
MAKING MODERN LIVING POSSIBLE One valve for all purposes TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION TGE: reliable, environmentally -friendly and easy to use Danfoss Refrigeration
More informationStandard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP
Standard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with
More informationStandard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP
Standard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with
More informationSANHUA S OFFER FOR REFRIGERATION APPLICATIONS
SANHUA S OFFER FOR REFRIGERATION APPLICATIONS Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with a global footprint and 30 years of experience.
More informationGeneral information on refrigerant controllers
General information on refrigerant controllers Condensing pressure controller The condensing or condenser pressure controller is a back pressure controller and its task is to maintain the condensing pressure
More informationThermostatic expansion valves for ammonia Type TEA
Data sheet Thermostatic expansion valves for ammonia Type TEA Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.
More informationFSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71
FSW Product guide F SECTION Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches For more information visit www.fsw.uk.com 71 Danfoss Expansion Valves T* Range - Order valve and orifice
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article
More informationJune 2001 / BULLETIN Way Valves. The right solenoid valve for any job.
June 01 / BULLETIN - 3-Way Valves The right solenoid valve for any job. Page 2 / Bulletin - Advantages Sporlan 3-Way Valves 3-Way Pilot eliminates costly high- to low-side leaks. "B" reduces total installed
More informationBulletin , March Electric Hot Gas Bypass Valves
Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital
More informationRD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet
RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction RD refrigerant distributors distribute liquid refrigerants from the thermostatic
More information64 66 Electronic Expansion Valve. 68 Q Series. 70 S Series T Series O Series R Series Four-Way Reversing Valve
Catalog bout Sanhua Solutions HVC&R Components 0 04 Thermal Expansion Valve Series Series 64 66 Electronic Expansion Valve C Series Q Series 06 Series 70 S Series T Series O Series R Series 09 8 Filter
More informationThese valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.
Type EBS/O Type EBS and O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer.
More informationFilter Driers with Replaceable Core
STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter
More informationRevolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability
Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability ETS Colibri brings to the market one of a kind, uniquely designed electric expansion valve. Innovative Design
More informationRefrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.
Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..
More informationLiquid Distributor Type RD
MAKING MODERN LIVING POSSIBLE Data sheet Liquid Distributor Type RD The RD refrigerant distributors distribute liquid refrigerants from the thermostatic expansion valve to individual sections of the evaporator.
More informationLINE COMPONENTS VALVES
VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. Large
More informationTube-in-tube heat exchanger Type HE
Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration plant. The purpose is to
More informationNovember 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES
November 2006 / BULLETIN -60 ELECTRIC DISCHARGE BYPASS VALVES PAGE 2 / Bulletin -60 10 FEATURES AND BENEFITS Direct temperature control Tight shutoff when closed Can be interfaced with direct digital controls
More informationPWM expansion valves 2028
PWM expansion valves 2028 Application Solenoid expansion valve Castel type 2028 regulates the refrigerant flow into the evaporator by modulating the opening time phase of the plug and so permitting a wide
More informationHANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1
HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 DIRECTIVE 2014/68/EU ISSUED OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 MAY 2014 ON PRESSURE EQUIPMENT Directive 2014/68/EU (PED Recast) applies to the design,
More informationEnergy Use in Refrigeration Systems
2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is
More informationEmerson Superheat Control. The smart solution for your application
Emerson Superheat Control The smart solution for your application Trust in Emerson Climate Technologies for reliable, precise and efficient superheat control. When it comes to superheat control, Emerson
More informationTube-in-tube heat exchanger Type HE
MAKING MODERN LIVING POSSIBLE Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationRESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES
SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant
More informationZero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.
Danfoss components for hydrocarbon refrigeration Leapfrog Extensive to a portfolio long-term and solution expertise with for safe Danfoss and optimised wide product use of hydrocarbons portfolio for hydrocarbons
More informationDescription Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)
INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationPressure switch KPU. Data sheet
Data sheet Pressure switch KPU The KPU switches are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or too high discharge. They can also
More informationT2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.
DANFOSS THERMOSTATIC EXPANSION - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. FEATURES Large temperature
More informationy Small dimensions. Easy to install in refrigerated counters or cold rooms
MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationAir cooled industrial chillers
Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage
More informationCoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor
CoolTeg Plus XC40 AC-TXC Direct expansion Air-conditioning unit with integrated compressor Application CoolTeg Plus XC40 is a revolutionary air-conditioning unit specifically designed for installation
More informationAir Cooled Packaged Systems AIRAH Back to Basics
Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability
More informationFan speed controller Type Saginomiya XGE
Data sheet Fan speed controller Type Saginomiya Fan speed controller stabilizes condensing pressure by changing condenser s fan speed. The controller reduces fan noise and saves energy in low ambient conditions.
More informationRefrigerant Valves/Accessories
Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating
More informationSporlan Valve Division Parker Hannifan/CIC Group
www.parker.com/cic Sporlan Valve Division Parker Hannifan/CIC Group Matt McGrath, SW Regional Sales Manager Bob Dolan, Sales Engineer - Atlanta www.parker.com/cic Why Discuss TEVs Today? Expansion Valves
More informationREFRIGERATION PRODUCTS
SE REFRIGERATION PRODUCTS Smart Electric products offer reliable and longer lasting solutions for refrigeration. We know how important it is to keep systems clean and running at its full efficiency for
More informationJCseries EVAPORATIVE CONDENSER. engineering data
JCseries EVAPORATIVE CONDENSER engineering data Recold JC Series Evaporative Condenser Contents 2 Construction... 3 Schematic... 4 Engineering Data... 5 Selection Procedure... 6-9 Multi-Circuited Selection
More informationBASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation
INTRODUCTION In recent years air conditioning industry technology has advanced rapidly. An important byproduct of this growth has been development of the heat pump. Altogether too much mystery has surrounded
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationIntroduction of Hanbell and
Introduction of Hanbell and RC2 Series Screw Compressor Jude Chen April 2, 2007 Content 1.Hanbell Company Profile 2.Hanbell Machinery & Production 3.Basic Mechanism of Hanbell Screw Compressor 4.Hanbell
More informationContour TM Screw Compressors
Contour TM Screw Compressors Semi-Hermetic Compact Operating Instruction SCH1 High Temp Compressors Form No. 99-77 1. Introduction This series of semi-hermetic compact screw compressors is designed for
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationEC3-X33 Stand-alone Superheat Controller Technical Data
Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,
More informationInstallation Manual BCS2000/3000
Installation Manual BCS2000/3000 Supplies Needed for Installation 1. 3/8 and 5/8 copper tubing. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120v 15A circuit for
More informationThomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.
Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration
More information13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationwater to water heat pumps
AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationCondensate Drain Valves
Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions
More informationApplication and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS
Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A900-22007), 120/208/240/1/60, R404A, LT/MT APPS Introduction The superheat controller is designed
More informationHITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -
HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE - Nominal Cooling Capacity Range 112 kw to 1,080 kw at 50Hz 32 USRT to 307 USRT at 50Hz 96,320 kcal/h to 928,800 kcal/h at 50Hz 382,000 Btu/h to 3,685,000
More informationREFRIGERATION PRODUCTS
REFRIGERATION PRODUCTS Product Catalog REFRIGERATION PRODUCTS PAUL MUELLER COMPANY Table of Contents 3 x 5 Falling Film Chiller.................................... 1 4 x 8 Falling Film Chiller...................................
More informationChapter-8 Capacity Control of Refrigeration Systems
Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control
More informationSemi-hermetic GEA Bock Compressors. Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world
Semi-hermetic GEA Bock Compressors Single-stage and Two-stage Reciprocating Compressors HG (HA) engineering for a better world GEA Refrigeration Technologies In touch with our customers GEA Refrigeration
More informationBALANCED PORT Q-VALVE
March 2001 / BULLETIN 10-10-6 ELEMENT BALANED PORT Q-VALVE ARTRIDGE BODY Page 2 / BULLETIN 10-10-6 Introducing the Balanced Port -Valve The BQ combines the flexibility of the replaceable cartridge style
More informationSystem Considerations for Refrigerant Blends with Temperature Glide
System Considerations for Refrigerant Blends with Temperature Glide Theory and Practical Retrofit Guidance Table of Contents 1 2 3 4 5 Blend and Glide Basics... 3 1.1 Superheat and Subcooling of Refrigerant
More informationHead Pressure Control Valves
Head ontrol s High and Low mbient Stability The design of air conditioning systems utilizing air cooled condensing units involves two main problems that must be solved if the system is to operate reliably
More informationEasy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow
Quick Selection Guide - 206 Products and technologies for all your application needs, today and tomorrow REFRIGERATION & AIR CONDITIONING Automatic Controls Condensing Units Compressors Easy Find the right
More informationMAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines
MAKING MODERN LIVING POSSIBLE MLZ / MLM Refrigeration scroll compressors 50-60 Hz - R404A - R507 - R134a - R22 Selection & application guidelines Contents Features... 4 Scroll compression principle...
More informationprecision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs
next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled
More informationOIL SEPARATORS APPLICATIONS
OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1 and are subject
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationAlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration
AlfaNova the first fusion-bonded plate heat exchanger A product brochure for AlfaNova within Industrial Refrigeration AlfaNova A new concept for plate heat exchangers Out of the extreme heat in our furnaces
More informationInstruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS
English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual
More informationM5200 Industrial Pressure Transducer
SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound
More informationProduct Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling
Product Data 28CB, Direct-Expansion Evaporator Coils 7 1 / 2 and 10 Nominal Tons Cooling 28CB Direct-expansion evaporator coils easily accommodate upflow or horizontal light-commercial applications Features/Benefits
More informationRQE Series Temperature Controllers
RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature
More informationMEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications
MEAS 5700 Subermsible Liquid Level Pressure Transducer Features Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.25% Accuracy
More informationAHU Plus. DX Air Handling Units
AHU Plus DX Air Handling Units AHU Plus DX DX Air Handling Units AHUPlusDX-TH: DX Air Hadling Unit with 100% Fresh Air AHUPlusDX -IGK: DX Air Hadling Unit with 100% Fresh Air and Heat Recovery AHUPlusDX-KH:
More informationDual Pressure Controls
PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393
More informationTHERMOSTATIC EXPANSION VALVES
SPORLAN EXPANSION VALVES Selective Thermostat Charges Designed to provide optimum performance for all applications air conditioning and heat pump, medium and low temperature refrigeration. Thermostatic
More informationCatalog. Self-operated Regulators Volume 2 Temperature Regulators
Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure
More informationThermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostats type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical data... 3 Regulating ranges... 4 Ordering... 4 Contact systems...
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationB24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)
ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400
More informationEasy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017
Quick Select Guide 2017 Products and technologies for all your application needs, today and tomorrow REFRIGERATION & AIR CONDITIONING COMPONENTS Easy Find the right products fast with our Quick Select
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationCompressed air preparation Compressed air storage Moisture management. Catalog #1
Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.
More informationACMVTECH HIGH EFFICIENCY UNITARY AHU
HIGH EFFICIENY UNITARY AHU 50 / 60 Hz R-134A, R407c R-407F, R-410A ACMVTECH HIGH EFFICIENCY UNITARY AHU WATER COOLED CONDENSERS VARIABLE and CONSTANT SPEED VSD FANS ; VSD COMPRESSORS ACMCVTECH UNITARY
More informationAs a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.
NOMENCLATURE INTRODUCTION The HTT HWDX water-cooled chillers range is the latest addition to HTT s growing family of commercial products, featuring the most current technologies advances. The HWDX main
More information