Product Data. Fig. 1 - Unit 50VL -A

Size: px
Start display at page:

Download "Product Data. Fig. 1 - Unit 50VL -A"

Transcription

1 50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes ) Product Data Fig. 1 - Unit 50VL -A A09033 Single-Packaged Products with Energy -Saving Features and PuronR refrigerant. S SEER / 12.0 EER S Factory -Installed TXV S ECM Motor-Standard S Low Sound Levels FEATURES/BENEFITS One-piece cooling unit with optional electric heater, low sound levels, easy installation, low maintenance, and dependable performance. Puron Environmentally Sound Refrigerant is Carrier s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. The most important advantage of Puron refrigerant is that it has not been banned in future air conditioning systems as the traditional refrigerant R -22 has been. Puron refrigerant is in service in over 100,000 systems proving highly reliable, environmentally sound performance. Easy Installation Factory -assembled package is a compact, fully self -contained, electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard cooling sizes with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design On the inside a high -tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High -efficiency design offers SEER (Seasonal Energy Efficiency Ratios) of 14.2 to (See page 4.) Durable, dependable components Scroll Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. ECM Motor is standard on all 50VL -A models. Direct -drive PSC (Permanent Split Capacitor) condenser -fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40_F (4.4_C) outdoor temperature. Motormasterr II low ambient kit is available as a field -installed accessory. Thermostatic Expansion Valve - A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 73dBA. (See Page 4.) Easy to service cabinets provide easy 3 panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with a mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4 -in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy. 1

2 Standard horizontal metal duct covers with insulation come with the unit and cover the horizontal duct openings. These can be left in place if the units are converted to downflow. Cabinets are constructed of heavyduty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator/heat exchanger compartment are insulated with cleanable semi -rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. TABLE OF CONTENTS FEATURES/BENEFITS MODEL NUMBER NOMENCLATURE... 3 AHRI CAPACITIES... 4 PHYSICAL DATA... 5 OPTIONS AND ACCESSORIES... 6 BASE UNIT DIMENSIONS ROOF CURB ACCESSORY SELECTION PROCEDURE PERFORMANCE DATA TYPICAL PIPING AND WIRING APPLICATION DATA ELECTRICAL DATA TYPICAL WIRING SCHEMATICS CONTROLS GUIDE SPECIFICATIONS

3 MODEL NUMBER NOMENCLATURE 50VL --- A Type of Unit 50VL --- Single Packaged Air Conditioner tem N/A Major Series Options FE --- Economizer (3 Phase Only) TF --- Filter Rack TP --- Base unit with tin plated indoor coil hairpins (Single Phase Only) See Price Page for full list of factory options. Only used if ordering an option Nominal Cooling Tons Tons Tons Tons Tons Tons N/A Minor Series Electrical Supply / / Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to 3

4 AHRI* CAPACITIES Cooling Capacities and Efficiencies 50VL-A NOMINAL TONS STANDARD CFM COOLING CAPACITY EER SEER LEGEND db --- Sound Levels (decibels) db Dry Bulb SEER Seasonal Energy Efficiency Ratio wb Wet Bulb COP---Coefficient of Performance * Air Conditioning, Heating & Refrigeration Institute. **At A conditions---80_f (26.7_C) indoor db/67_f (19.4_C) indoor wb & 95_F (35_C) outdoor db. { Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240. Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80 F (26.7_C) db, 67 F wb (19.4_C) indoor entering ---air temperature and 95 F db(35_c) outdoor entering---air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. A -WEIGHTED SOUND POWER LEVEL (dba) MODEL 50VL-A SOUND RATING TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) NOTE: Tested in accordance with AHRI Standard 270 (not listed in AHRI). 4

5 PHYSICAL DATA Physical Data -Unit 50VL -A UNIT SIZE NOMINAL CAPACITY (ton) / /2 4 5 SHIPPING WEIGHT* lb. SHIPPING WEIGHT* (kg) COMPRESSORS Quantity REFRIGERANT (R---410A) Quantity lb Quantity (kg) REFRIGERANT METERING DEVICE OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) OUTDOOR FAN Nominal Cfm Diameter in. Diameter (mm) Motor Hp (Rpm) INDOOR COIL Rows...Fins/in. Face Area (sq ft) INDOOR BLOWER Nominal Cooling Airflow (Cfm) Size in. Size (mm.) Motor HP (RPM) HIGH---PRESSURE SWITCH (psig) Cut---out Reset (Auto) LOSS --- OF --- CHARGE / LOW --- PRES- SURE SWITCH (Liquid Line) (psig) cut---out Reset (auto) RETURN---AIR FILTERS } Throwaway Size in. Throwaway Size (mm) /10 (810) x10 254x254 1/2 (1050) 20x20x1 508x508x /10 (810) x10 254x254 1/2 (1050) 20x24x1 508x610x /5 (810) x x254 3/4 (1000) Scroll 1 TXV /5 (810) x x254 3/4 (1075) 650 +/ / / / x30x1 610x762x /5 (810) /5 (810) x x254 11x x (1075) 1.0 (1040) 24x36x1 610x914x25 *For 460 volt units add 14 lb (6.35 kg) to the shipping weight. { Required filter sizes shown are based on the larger of the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high---capacity type. Air filter pressure drop for non---standard filters must not exceed 0.08 in. W.C. } If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity. Electric Heat Pressure Drop Tables (IN. W.C.) Small Cabinet: STATIC CFM kW kw kw kw Large Cabinet: STATIC CFM kW kw kw kw

6 OPTIONS AND ACCESSORIES ITEM DESCRIPTION FACTORY INSTALLED OPTION Coil Options Base unit with tin plated indoor coil hairpins X Compressor Start Kit Compressor Start Kit assists compressor start--- up by providing additional starting torque on sing phase units only. Corporate Thermostats Thermostats provide control for the system heating and cooling functions. Crankcase Heater Crankcase Heater provides anti--- floodback protection for low--- load cooling applications. Horizontal Economizer with solid state controls and barometric relief dampers includes filter racks and provide outdoor air during cooling and Economizer reduce compressor operation. Vertical Economizer with solid state controls and barometric relief dampers includes filter racks and provide outdoor air during cooling and X reduce compressor operation. FIELD INSTALLED ACCESSORY Electric Heaters Electric Heat Supplement X Filter Rack Filter Rack features easy installation, serviceability, and high---filtering performance for vertical applications. Includes 1--- in. filter. X X Flat Roof Curbs Flat Roof Curbs in both in (279 mm) and in. (356 mm) sizes are available for roof mounted applications. X Low Ambient Kit Low Ambient Kit (Motormaster II Control) allows the use of mechanical cooling down to outdoor temperatures as low as 0 F ( C) when properly installed. X Manual Outside Air Damper Square --- to --- Round Duct Transition Kit Time Guard II Manual Outside Air Damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. Square---to---Round Duct Transition Kit enable size units to be fitted to 14 in (356 mm). round ductwork. Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown of the compressor. Not required when a corporate programmable thermostat is applied or with a RTU--- MP control. Allows you to power the electric heater and unit contactor separately by Dual Point Electric Heaters having two individual field power supply circuits connected respectively. *Refer to Price Page for application detail. X X X* X X X X X X Electric Heaters CATALOG NOMINAL FUSE USED WITH SIZES ORDERING NO. CAPACITY (kw) QTY ELECTRIC HEATERS (208/230 SINGLE PHASE 60 Hz) CPHEATER052A X X X X X X CPHEATER064A X X X X X X CPHEATER069A X X X X X X CPHEATER070A X X X X X X CPHEATER065A X X X X CPHEATER050A X X X X X X CPHEATER051A X X X CPHEATER066A X X X X X CPHEATER053A X X X CPHEATER054A X X X ELECTRIC HEATERS (208/230 THREE PHASE 60 Hz) CPHEATER055A X X X X X CPHEATER056A X X X X X CPHEATER068A X X X X X CPHEATER057A X X X X X CPHEATER058A X X X X X CPHEATER059A X X X ELECTRIC HEATERS (460 THREE PHASE 60 Hz) CPHEATER060A X X X X CPHEATER061A X X X X CPHEATER062A X X X X CPHEATER063A X X X NOTE: Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages. X = Approved combinations. Minimum Airflow for Safe Electric Heater Operation (CFM) SIZE Cfm

7 ECONOMIZER COIL FILTER ECONOMIZER SIDE VIEW CAULK BOTTOM CORNER OF ECONOMIZER ON EACH SIDE Vertical Economizer FI LTER COIL ECONOMIZER BASE FLANGE ON BASE DETAIL FILTER RACK BEND FLANGE AT 90 -SCREW TO DIVIDER WITH 1-IN. (25 mm) SCREW EV APORATOR COIL TOP FILTER RACK Horizontal Economizer MANUAL OUTSIDE AIR DAMPER REPLACEMENT PANEL MANUAL OUTSIDE AIR HOOD DAMPER BLADE BOTTOM FILTER RACK A

8 UNIT DIMENSIONS - 50VL -A24-36 A

9 UNIT DIMENSIONS - 50VL -A42-60 A

10 ROOF CURB ACCESSORY - 50VL -A24-60 B Dashed lines show cross support location for large basepan units. HVAC unit base rails HVAC unit basepan G C Sealing Gasket Anchor screw Flashing field supplied Roofing material field supplied Cant strip field supplied *Provided with roofcurb Roofcurb Wood nailer* Roofcurb* Insulation (field supplied) A F H D SMALL/COMMON CURB E A09413 A09090 ROOF CURB DETAIL B G C SUPPLY AIR SMALL BASE UNIT F A H E RETURN AIR LARGE BASE UNIT D UNIT PLACEMENT ON COMMON CURB A09094 LARGE CURB A09415 SMALL OR LARGE BASE UNIT A09414 UNIT SIZE Small or Large Large CATALOG NUMBER CPRFCURB010A00 CPRFCURB011A00 CPRFCURB012A00 CPRFCURB013A00 A IN. (mm) 11 (279) 14 (356) 11 (279) 14 (356) B (small/common base) IN. (mm)* 10 (254) 14 (356) B (large base) IN. (mm)* 14 (356) C IN. (mm) 16 (406) D IN. (mm) 47.8 (1214) E IN. (mm) 32.4 (822) 43.9 (1116) F IN. (mm) 2.7 (69) G IN. (mm) 30.6 (778) 42.2 (1072) H IN. (mm) 46.1 (1170) * Part Numbers CPRCURB010A00 and CPRCURB011A00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16 -gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1 -in. (25.4 mm) thick fiberglass 1 lb. density. 10

11 SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at design conditions: Given: Required Cooling (TC)... 34,000 Btuh Sensible Heat (SHC)... 24,000 Btuh Required Heating... 12,500 Btuh Condenser Entering Air Temperature F(35 C) Indoor-Air Temperature F (26 C) edb 67 F (19 C) ewb Evaporator Air Quantity CFM External Static Pressure IN. W.C. Electrical Characteristics Select unit based on required cooling capacity. Enter Net Cooling Capacities table at condenser entering temperature of 95 F (35 C), indoor air entering at 1200 cfm and 67 F (19 C) ewb (entering wet bulb). The unit will provide a total capacity of 34,200 Btuh and a SHC of 24,500 Btuh. 3. Select electric heat. The required heating capacity is 15,000 Btuh. Determine additional electric heat capacity in kw. 15,000 Btuh = 4.4kW of heat required 3,414 Btuh/kW Enter the electric Heater Packages table for 208/240, single-phase, 50VL -A36 unit. The 5 kw heater at 240v most closely satisfies the heating required. To calculate kw at the 208v, multiply the heater kw by multiplication factor 0.75 found in the Wattage Multiplication Factors table. 5 kw x 0.75 = 3.75 kw 3.75 kw x 3414 = Btuh 4. Determine fan speed and power requirements at design conditions. Before entering the air delivery tables, calculate the total static pressure required. From the given example, the Wet Coil Pressure Drop Table, and the Filter Pressure Drop Table: External Static Pressure IN. W.C. Filter IN. W.C. Wet Coil Pressure Drop IN. W.C. Static Pressure IN. W.C. Enter the table for Wet Coil Air Delivery horizontal discharge, 230. At 0.33 IN. W.C. ESP (external static pressure) and medium speed, the fan will deliver 1293 cfm. Adjusting for 208v, the motor delivers 114 cfm (deduct 10%). 5. Select unit that corresponds to power source available. The Electrical Data Table shows that the unit is designed to operate at

12 PERFORMANCE DATA 50VL -A24 EVAPORATOR AIR CFM/BF 700/ / /0.04 EWB _F (_C) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens VL-A24 Outdoor Section With NONE Indoor Section (22.2) See Legend and Notes on Page

13 PERFORMANCE DATA (CONT) 50VL -A30 EVAPORATOR AIR CFM/BF 875/ / /0.05 EWB _F (_C) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens VL-A30 Outdoor Section With NONE Indoor Section (22.2) See Legend and Notes on Page

14 PERFORMANCE DATA (CONT) 50VL -A36 EVAPORATOR AIR CFM/BF 1050/ / /0.06 EWB _F (_C) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens VL-A36 Outdoor Section With NONE Indoor Section (22.2) See Legend and Notes on Page

15 PERFORMANCE DATA (CONT) 50VL -A42 EVAPORATOR AIR CFM/BF 1225/ / /0.05 EWB _F (_C) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens VL-A42 Outdoor Section With NONE Indoor Section (22.2) See Legend and Notes on Page

16 PERFORMANCE DATA (CONT) 50VL -A48 EVAPORATOR AIR CFM/BF 1400/ / /0.06 EWB _F (_C) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens VL-A48 Outdoor Section With NONE Indoor Section (22.2) See Legend and Notes on Page

17 PERFORMANCE DATA (CONT) 50VL -A60 EVAPORATOR AIR CFM/BF EWB _F (_C) CONDENSER ENTERING AIR TEMPERATURES _F (_C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Sens Sens Sens Sens Sens Sens 1750/ / / (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.8) 62 (16.6) 63* (17.2) 67 (19.4) 72 (22.2)

18 PERFORMANCE DATA (CONT) * At 75 F (24 C) entering dry bulb---tennessee Valley Authority (TVA) rating conditions; all others at 80 F (27 C) dry bulb. LEGEND BF Bypass Factor edb Entering Dry---Bulb Ewb Entering Wet---Bulb kw Unit Power Input SHC Sensible Heat (1000 Btuh) TC (1000 Btuh) (net) rh Relative Humidity COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator---fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: t ldb = t edb --- Sensible capacity (Btuh) 1.10 x cfm t lwb = Wet---bulb temperature corresponding to enthalpy h lwb = h ewb --- total capacity (Btuh) air leaving evaporator coil ( h lwb) 4.5 x cfm Where: h ewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 805 F (26.6_C) edb temperature of air entering evaporator coil. Below 80_F (26.6_C) edb, subtract (corr factor x cfm) from SHC. Above 80_ F (26.6_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb ). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 18

19 PERFORMANCE DATA (CONT) Multiplication Factors HEATER kw RATING VOLTAGE DISTRIBUTION V/3/60 MULTIPLICATION FACTOR Dry Coil Air Delivery* - Horizontal Discharge - Unit 50VL -A24-60 UNIT MOTOR SPEED WIRE COLOR 50VL-A24 50VL-A30 50VL-A36 50VL-A42 50VL-A48 50VL-A60 EXTERNAL STATIC PRESSURE (IN. W.C.) Low Blue CFM Med-Low Pink CFM Medium 1 Red CFM Med-High Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM Medium Red CFM Med-High 1 Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM Medium 1 Red CFM Med-High Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM Medium Red CFM Med-High 1 Orange CFM High Black CFM Low Blue CFM Med-Low Pink CFM Medium 1 Red CFM Med-High Orange CFM High Black CFM Med-Low Pink CFM Medium 1 Red CFM Med-High Orange CFM High Black CFM * Air delivery values are without air filter and are for dry coil (See 50VL ---A Wet Coil Pressure Drop table). 1 Factory---shipped cooling speed Note: Deduct field---supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed. Note: Deduct 10% for 208 volt operation. 19

20 Dry Coil Air Delivery - Downflow Discharge UNIT MOTOR SPEED WIRE COLOR Low Blue MedLow Pink 50VLA24 Medium 1 Red MedHigh Orange High Black Low Blue MedLow Pink 50VLA30 Medium Red MedHigh 1 Orange High Black EXTERNAL STATIC PRESSURE (IN. W.C.) CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP BHP BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP

21 Dry Coil Air Delivery - Downflow Discharge UNIT MOTOR SPEED WIRE COLOR Low Blue MedLow Pink 50VLA36 Medium 1 Red MedHigh Orange High Black Low Blue MedLow Pink 50VLA42 Medium Red MedHigh 1 Orange High Black EXTERNAL STATIC PRESSURE (IN. W.C.) CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP

22 Dry Coil Air Delivery - Downflow Discharge UNIT 50VLA48 50VLA60 MOTOR SPEED WIRE COLOR Low Blue MedLow Pink Medium 1 Red MedHigh Orange High Black Low Blue MedLow Pink Medium 1 Red MedHigh Orange High Black *Air delivery values are without air filter and are for dry coil (See 50VL Wet Coil Pressure Drop table). 1 Factory -shipped cooling speed. NOTE: Deduct field -supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. Shaded areas indicate speed/static combinations that are not permitted. EXTERNAL STATIC PRESSURE (IN. W.C.) CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP

23 PERFORMANCE DATA (CONT) 50VL -A Wet Coil Pressure Drop (IN. W.C.) UNIT STANDARD CFM (SCFM) SIZE Economizer with 1 -in. Filter Pressure Drop (IN. W.C.) FILTER SIZE IN. (MM) CFM 12x20x1+12x20x1 (305x508x25+305x508x25) CFM 16x24x1+14x24x1 (406x610x25+356x610x25) CFM 16x24x1+18x24x1 (406x610x25+457x610x25) COOLING TONS 2.0, 2.5, , 4.0 STANDARD CFM (SCFM) Horizontal and Downflow Filter Pressure Drop Table (IN. W.C.) FILTER SIZE IN. (MM) CFM 12x20x1+12x20x1 (305x508x25+305x508x CFM 16x24x1+14x24x1 (406x610x25+356x610x25) CFM 16x24x1+18x24x1 (406x610x25+457x610x25) COOLING TONS 2.0, 2.5, , 4.0 STANDARD CFM (SCFM)

24 Electric Heat Pressure Drop Tables (IN. W.C.) Small Cabinet: STANDARD CFM (SCFM) STATIC kW kw kw kw Large Cabinet: STANDARD CFM (SCFM) STATIC kW kw kw kw

25 TYPICAL PIPING AND WIRING INDOOR THERMOSTAT RETURN AIR TOP COVER FROM POWER SOURCE DISCONNECT PER NEC* POWER ENTRY CONTROL ENTRY *NEC - NATIONAL ELECTRICAL CODE 25

26 APPLICATION DATA Condensate trap A 2 -in. (50.8 mm) condensate trap must be field supplied. Ductwork Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge Units are equipped with factory -installed inserts in the downflow openings. Removal of the inserts is similar to removing an electrical knock -out. Maximum cooling airflow To minimize the possibility of condensate blow -off from the evaporator, airflow through the units should not exceed 450 cfm per ton. Minimum cooling airflow Minimum cooling airflow is 350 cfm per ton. Minimum ambient cooling operation temperature All standard units have a minimum ambient operating temperature of 40_F (4_C). With accessory low ambient temperature kit, units can operate at temperatures down to 0_F (-17_C). 26

27 ELECTRICAL DATA UNIT NOMINAL VOLTAGE RANGE COMPRESSOR OFM IFM MIN MAX RLA LRA FLA FLA 50VL-A / VL-A / VL-A / VL-A / VL-A / VL-A VL-A / VL-A / VL-A VL-A / VL-A / VL-A VL-A / VL-A / ELECTRIC HEAT POWER SUPPLY NOMINAL kw FLA MCA MOCP -/- -/ /5 18.1/ / /35 5.4/ / / /45 7.5/ / / /60 -/- -/ /5 18.1/ / /35 5.4/ / / /45 7.5/ / / / / / / /90 -/- -/ /5 10.4/ / /25 7.5/ / / / / / / /60 -/- -/ /5 18.1/ / /35 5.4/ / /45 40/45 7.5/ / / / / / / /90 -/- -/ /5 10.4/ / /25 7.5/ / / / / / / /60 -/- -/ / / / / / / /- -/ /5 18.1/ / /40 5.4/ / /45 40/45 7.5/ / / / / / / /90 15/ / / /125 -/- -/ /5 10.4/ / /35 7.5/ / / / / / / /60 15/ / / /70 -/- -/ / / / / / / / / /- -/ /5 18.1/ / /50 5.4/ / /47 50/50 7.5/ / / / / / / /90 15/ / / /125 -/- -/ /5 10.4/ / /35 7.5/ / / / / / / /60 15/ / / /70 -/- -/ / / / / / / / / /- -/ /5 18.1/ / /60 5.4/ / /47 60/60 7.5/ / / / / / / /90 15/ / / /125 -/- -/ /5 10.4/ / /40 7.5/ / / / / / / /60 15/ / / /70 27

28 ELECTRICAL DATA (CONT) UNIT NOMINAL VOLTAGE RANGE COMPRESSOR OFM IFM MIN MAX RLA LRA FLA FLA 50VL-A ELECTRIC HEAT POWER SUPPLY NOMINAL kw FLA MCA MOCP -/- -/ / / / / / / / / LEGEND FLA - Full Load Amps IDM - Inducer Motor IFM - Indoor Fan Motor LRA -Locked Rotor Amps MCA - Minimum Circuit Amps MOCP - Maximum Over Current Protection OFM - Outdoor Fan Motor RLA - Rated Load Amps A

29 CONNECTION WIRING SCHEMATIC 208/ A

30 LADDER WIRING SCHEMATIC 208/ A

31 CONNECTION WIRING SCHEMATIC 208/ A

32 LADDER WIRING SCHEMATIC 208/ A

33 1 1 1 R R Y R Y CONNECTION WIRING SCHEMATIC FIELD SUPPLY POWER L1 UNIT ONLY MAXIMUM WIRE SIZE 2 AWG. L3 YEL GRN CCH RED IF USED C YEL CONNECTION WIRING DIAGRAM DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING CAP YEL COMPRESSOR PLUG OFM FOR WIRING WITH ELECTRIC HEATERS SEE SCHEMATIC ON HEATER ACCESSORY. SCHEMATIC BLU YEL ECON PLUG L2 EQUIP_GND PNK PNK RED GRY ECON BLU SAT BLU YEL BLU TRAN RED YEL FU1 5 AMP FU2 5 AMP C C 460V 230V AUTOTRANSFORMER RED YEL BLU SEE NOTE 8 YEL GND GRN/YEL T1 T3 T2 GRN-YEL L2 GND L1 COM COMP SEE NOTE 5 & 6 1 IFM YEL BLU PNK RED ORN RED SEE NOTE 4 Y2 TSTAT GRY SEE NOTE 7 SEE NOTE 9 R C Y1 G DH RED YEL GRN BLU 3A 24VAC FUSE COM C COM COM LOW STD DEHUM HIGH IFB WHT VIO PNK ACCESSSORY ELECTRIC HEAT HR1 (5 ) WHT VIO HR1,2,3 & 4 (20 ) PNK HR1 HR4 HR2 W2 WHT GRY GRY HR1 & 2 (10 ) HR3 W3 VIO P1 C Y1/Y G Y2/DH W2 W3 P2 C W2 P4 C W2 W2 W3 W3 HR1,2 & 3 (15 ) HPS LPS BLU BLU C1 C C2 OUTDOOR FAN SECTION COMPRESSOR SECTION LPS UNIT COMPONENT ARRANGEMENT INDOOR FAN SECTION OFM CONTROL BOX AREA SINGLE PT. CONNECTION FOR ELECT.HEAT C COLOR CODE BLACK BLU BLUE BROWN GRY GRAY GRN GREEN ORN ORANGE PNK PINK RED RED VIO VIOLET WHT WHITE YEL YELLOW LEGEND FIELD SPLICE TERMINAL (MARKED) ENERGIZED TERMINAL (UNMARKED) SPLICE (IF USED) SPLICE (MARKED) FACTORY WIRING FIELD CONTROL WIRING FIELD POWER WIRING ACCESSORY OR OPTIONAL WIRING TO INDICATE COMMON POTENTIAL ONLY: NOT TO REPRESENT WIRING C CONTACTOR CAP CAPACITOR CCH CRANK CASE HEATER COMP COMPRESSOR MOTOR DH DEHUMIDIFICATION MODE DEHUM DEHUMIDIFICATION MODE ECON ECONOMIZER GND GROUND HPS HIGH PRESSURE SWITCH HR HEATER RELAY IFB INTERFACE FAN BOARD IFM INDOOR FAN MOTOR LPS LOW PRESSURE SWITCH OFM OUTDOOR FAN MOTOR STD STANDARD MODE TRAN TRANSFORMER HPS COMP C S CCH R CAP HC F IFM SEE HEATER SCHEMATIC FOR WIRING TRAN IFB 24V SPLICE BOX EQUIP. GND DISCONNECT PER NEC 24V POWER ENTRY NOTES: 1. IF ANY OF THE ORIGINAL WIRES FURNISHED ARE REPLACED, IT MUST BE REPLACED WITH TYPE 90 DEGREE C WIRE OR IT'S EQUIVALENT. 2. SEE PRICE PAGES FOR THERMOSTAT AND SUBBASES. 3. USE 75 DEGREE COPPER CONDUCTORS FOR FIELD INSTALLATION. 4. REFER TO INSTALLATION INSTRUCTIONS FOR CORRECT SPEED SELECTION OF IFM. 5. RELOCATION OF SPEED TAPS MAY BE REQUIRED WHEN USING FIELD INSTALLED ELECTRIC HEATERS, CONSULT INSTALLATION INSTRUCTIONS TO DETERMINE CORRECT SPEED TAP SETTING. 6. "DO NOT DISCONNECT PLUG UNDER LOAD." 7. THIS FUSE IS MANUFACTURED BY LITTELFUSE, P/N THESE FUSES ARE MANUFACTURED BY COOPER BUSSMAN, P/N FNQ-R-5 9. DEHUM FEATURE CANNOT BE USED WHEN ECONOMIZER IS INSTALLED. UNIT FACTORY-SHIPPED IN STD MODE. A

34 LADDER WIRING SCHEMATIC LADDER WIRING DIAGRAM DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING L2 L RED IF USED G/Y CCH OFM C R S GRN YEL 23 C L3 YEL 13 CAP YEL 11 BLU T2 T1 T3 COMP YEL YEL 13 CL G NX IFM G/Y 460V TRAN 460V YEL 13 RED 24V 24V R C Y1 G DH W2 W3 SEE NOTE 7 RED YEL GRN BLU WHT VIO RED FUSE 3A P1-1 P1-2 P1-3 P1-4 P1-5 P1-6 P1-7 24VAC IFB "R" "C" "Y1/Y" "G" "Y2/DH" "W2" "W3" G/Y Y2 VIO P2-1 P2-2 P2-3 P2-4 Y HPS BLU LPS BLU C1 C C2 C,TRAN ACCESSORY ELECTRIC HEAT YEL P4-1 P4-2 P4-3 P4-4 P4-5 LOW STD DEHUM HIGH WHT VIO PNK GRY SEE NOTE 4 WHT VIO SEE NOTE 9 PNK GRY BLU PNK RED ORN HR1 HR4 HR2 HR IFM C ECON HARNESS PNK PNK COM C BLU BLU SAT C G/Y RED 50VL D 34

35 CONTROLS Operating sequence Cooling When the system thermostat calls for cooling, 24 V is supplied to the Y and G terminals of the thermostat. This completes the circuit to the contactor coil (C) and indoor (evaporator) fan relay (IFR). The normally open contacts of energized C close and complete the circuit through compressor motor (COMP) to outdoor (condenser) fan motor (OFM). Both motors start instantly. The set of normally open contacts of energized IFR close and complete the circuit through IFM. The IFM starts instantly. On the loss of the thermostat call for cooling, 24 V is removed from both the Y and G terminals (provided the fan switch is in the AUTO position) de-energizing the compressor contactor and opening the contacts supplying power to compressor/ofm. After a 90 -second delay, the IFM shuts off. If the thermostat fan selector switch is in the ON position, the IFM will run continuously. For the 460 V units there is a step down autotransformer supplying 230 V to the Indoor Fan Motor. NOTE: On units with a Time Guard II device: Once the compressor has started and then stopped, it cannot be restarted again until 5 minutes have elapsed. Heating If accessory electric heaters are installed, on a call for heat, circuit R -W is made through the thermostat contacts. Circuit R -G is made which energizes the IFR. If the heaters are staged, then the thermostat closes a second set of contacts (W2) when second stage is required. When thermostat is satisfied, contacts open, deenergizing the heater relay and the IFR. 35

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) 607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data A09033 Fig. 1 - Unit 607C - -A Single-Packaged Products

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt 13 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

Product Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

Product Data PA4G - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) - - A 14 SEER SINGLE-PACKAGED AIR CONDITIONER SYSTEM WITH R-410A REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60) Product Data Fig. 1 - Unit - -A A09183 Single-Packaged Products with Energy

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

Product Data. Fig. 1 - Unit 50ES -A

Product Data. Fig. 1 - Unit 50ES -A 50ES---A Comfortt 13 SEER Single---Packaged Air Conditioner tem With Puron (R---410A) Refrigerant Single and Three Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50ES -A A09034

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Product Data. Fig. 1 - Unit 50EZ -A

Product Data. Fig. 1 - Unit 50EZ -A 50EZ---A Comfortt Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single --- And Three ---Phase Units 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50EZ -A A09034 Single-Packaged

More information

WPH4 Product Specifications

WPH4 Product Specifications Up to 14.5 SEER, 8.0 HSPF PACKAGE HEAT PUMP 2 to 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Product Data. Fig. 1 - Unit 50VL -A

Product Data. Fig. 1 - Unit 50VL -A 50VL---A Performancet 14 SEER Single---Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single--- And Three---Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VL -A A09033

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/ , REFRIGERATION CIRCUIT EASY TO INSTALL AND SERVICE SOUND REFRIGERANT ENVIRONMENTALLY PAD3 Product Specifications 13 SEER PACKAGE AIR CONDITIONER, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant Scroll

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/230 1 60, Single Phase REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

PHD3. Product Specifications

PHD3. Product Specifications SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, 7.7 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant

More information

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number SOUND REFRIGERANT ENVIRONMENTALLY PHD4 Product Specifications 14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/230 3 60, 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

Product Data. Fig. 1 - Unit 50XL -A

Product Data. Fig. 1 - Unit 50XL -A 50XL---A Infinityr 15 SEER Single---Packaged Air Conditioner with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 50XL -A A09032 Single-Packaged

More information

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons Product Data 50JS Single-Packaged Heat Pump Units 1 1/2 to 5 Nominal Tons UNIT 50JS (STANDARD) Single-Packaged Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES 024-048) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S Easy installation design

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. 13 SEER

More information

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50JZ Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF up

More information

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Products with Energy-Saving Features and Puron refrigerant. 12 SEER HSPF

More information

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT (STANDARD) Single-Package Heat Pump for Residential and Light Commercial Applications Low Sound Levels 10 SEER Features/Benefits

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons Product Data 50HX High Efficiency Single-Packaged Heat Pumps 2 to 5 Nominal Tons UNIT 50HX High Efficiency, Single-Packaged Heat Pump for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons Product Data 50ZP Single-Package Electric Cooling Units 2 to 5 Nominal Tons Single Package Air-Conditioning Units with: easy installation design corrosion-proof basepan pre-painted steel cabinet sloped

More information

Model 655A Sizes

Model 655A Sizes Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential,

More information

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES )

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES 024-060) Product Data Fig. 1 - Unit A06079 Single-Packaged Products with Energy

More information

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits Product Data 50ZH Single-Packaged Heat Pumps 2 to 5 Tons Single-Package Heat Pump Units with: easy installation design corrosion-proof basepan redesigned aerodynamic fan blade for reduced sound sloped

More information

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron Performancet 13 SEER Single---Packaged HYBRID HEATr Dual Fuel System with Puronr (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 024---060) Product Data C99088 Fig. 1 - Unit Single-Packaged

More information

Model 704B Sizes

Model 704B Sizes SINGLE-PACKAGED ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant Model 704B Sizes 024-060 2 To 5 Nominal Tons UNIT 704B Single-Packaged Products with Energy-Saving Features and Puron refrigerant.

More information

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons PERFORMANCE 13 SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron refrigerant. Low

More information

Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES )

Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES ) SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES 024-060) Product Data Single-Packaged Products with Energy -Saving Features and PuronR

More information

Product Data. Fig. 1 - Unit 48XL -A

Product Data. Fig. 1 - Unit 48XL -A 48XL---A Infinity 15 SEER Single---Packaged Air Conditioner and Gas Furnace with Puron (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Product Data Fig. 1 - Unit 48XL -A A09032

More information

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons Product Data 50SX High Efficiency Single-Packaged Cooling Units 2 to 5 Nominal Tons 50SX High Efficiency, Single-Packaged Cooling Unit for Manufactured Housing and Residential use. Features/Benefits One-piece

More information

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons Product Data The 50EES unit with ZP technology is a package air conditioner for manufactured housing, residential, and light commercial

More information

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons Product Data 50ZP Single-Package Air Conditioners 2 to 5 Tons UNIT 50ZP The 50ZP unit is a packaged air conditioner for manufactured housing, residential, and light commercial applications. The 50ZP unit

More information

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons Product Data UNIT Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3 SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS Model 702A 2 to 5 Nominal Tons UNIT 702A Single packaged Cooling Unit for Residential and Light Commercial use. FEATURES/BENEFITS One-piece cooling unit with

More information

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons Product Data 50GS Single-Packaged Electric Cooling Units 1-1/2 to 5 Nominal Tons UNIT 50GS Single packaged Cooling Unit for Residential and Light Commercial use. Features/Benefits One-piece cooling unit

More information

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES FACTORY- ASSEMBLED PACKAGE is a compact, fully self-contained, electric cooling unit with horizontal supply and return ducts. The PA1Z units are available in a variety of standard cooling sizes with voltage

More information

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons Product Data 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons UNIT 50GL Single-Package Products with Energy-Saving Features and Puron refrigerant. Low Sound

More information

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant Product Data Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant 2 to 5 Nominal Tons Single-Packaged Products with Energy-Saving Features and

More information

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits Product Data 50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant 7 to 14 kw (2 to 4 Nominal Tons) UNIT 50GL (50HZ) Single-Packaged Products with Energy-Saving Features

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

Product Data. Unit 574D

Product Data. Unit 574D SINGLE -PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R -410A) REFRIGERANT SINGLE- AND 3 -PHASE UNITS 1-1/2 to 5 NOM TONS (SIZES 018-060) Product Data Single-Packaged Products with Energy -Saving

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons Product Data Convertible duct configuration Unit is designed for easy use in either downflow or horizontal

More information

Product Data. Features/Benefits

Product Data. Features/Benefits , N 3-PHASE SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons Product Data UNIT Single-Package Rooftop Products with Energy-Saving Features and

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Model 583A Sizes

Model 583A Sizes SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 583A Sizes 024-060 2 to 5 Nominal Tons UNIT 583A Single-Packaged Rooftop Products with Energy-Saving Features. Direct Spark Ignition Low Sound Levels

More information

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving Product Data 50AH Horizontal Indoor Single-Package Cooling Units 2 to 5 Nominal Tons Single Package Cooling Units Featuring: compact design flexibility easy maintenance high quality and reliability quiet

More information

Product Data. Features/Benefits

Product Data. Features/Benefits PERFORMANCE 13 (N) SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons Product Data UNIT Single-Packaged Products with Energy-Saving Features and Puron

More information

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons Product Data 50LJQ Single-Package Rooftop Heat Pump Units Nominal 3 to 10 Tons Single-Package Rooftop Heat Pump Units with the following Standard Features: 2-in. return-air filters Acutrol refrigerant

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

Model 574B Sizes

Model 574B Sizes SINGLE-PACKAGED GAS HEATING/ELECTRIC COOLING UNITS Model 574B Sizes 024-060 2 to 5 Nominal Tons Low NOx Models Available UNIT 574B Single-Packaged Rooftop Products with Energy-Saving Features and Puron

More information

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant Package Rooftop Units Quality Assurance Certificate Reg. No: 04 100 950420 Subject to change without notice Manufacturing point: Jeddah, Saudi Arabia Nearest port of embarkation: Jeddah Islamic port Product

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons Product Data 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units 2 to 5 Nominal Tons UNIT 48GX (Shown with Accessory Wire Grille) Single-Package Rooftop Products with Energy-Saving Features. Direct

More information

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT -1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

Product Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE

Product Data PY3P SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R-22 REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES ) 1 & 3 PHASE SINGLE-PACKAGED GAS FURNACE/AIR CONDITIONER SYSTEM WITH R- REFRIGERANT 2 TO 5 NOMINAL TONS (SIZES 024-060) 1 & 3 PHASE Product Data Convertible duct configuration Unit is designed for easy use in either

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp. PHE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE HEAT PUMP UNIT - 13 & 15 Ton REFRIGERATION CIRCUIT Single reciprocating semi -hermetic compressor on all 13 ton units. Dual semi -hermetic compressors

More information

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons 007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),

More information

Product Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons

Product Data. Features/Benefits. 50BYN Single-Package Air Cooled Vertical Packaged Units. 5to20Tons Product Data 50BYN Single-Package Air Cooled Vertical Packaged Units 5to20Tons The 50BYN units are single-package cooling units with integral air-cooled condensers designed for indoor installations. They

More information

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh PAE Product Specifications ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT - 278 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, Electrically

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel

More information

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS -3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams DIAGRAM INDEX 50TFF004-014 Single Package Rooftop Electric Cooling Units Wiring Diagrams DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 50TFF Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION Bryant Air Conditioning Model 581A COMMERCIAL SINGLE PACKAGE ROOFTOP Sizes 155-240 GAS HEATING/ELECTRIC COOLING UNITS 13 to 20 Tons Model 581A155,180 Model 581A240 DESCRIPTION The 581A gas heating/electric

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil A13303 Fig. 1 - FPM(A,B)NU Uncased Horizontal Fan Coil (FPMANU model shown) Fig. 2 - FPM(A,B)NC Cased Horizontal Fan Coil

More information

Model 542F Size 180 COMMERCIAL ROOFTOP PACKAGED HEAT PUMP. Bryant Air Conditioning. Form No. PDS 542F.180.2B. 15 Tons DESCRIPTION

Model 542F Size 180 COMMERCIAL ROOFTOP PACKAGED HEAT PUMP. Bryant Air Conditioning. Form No. PDS 542F.180.2B. 15 Tons DESCRIPTION Bryant Air Conditioning COMMERCIAL ROOFTOP PACKAGED HEAT PUMP Model 542F Size 180 15 Tons MODEL 542F DESCRIPTION Model 542F is a high-efficiency, single-package heat pump that has an energy efficiency

More information

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg) FCM4X Product Specifications FAN COILS WITH OBSERVERt COMMUNICATING CONTROL ALL MODELS S 2, 3, 4, and 5 Tons S Multi- position installation S Communicating, self configuring when used with Observer Communicating

More information

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh PAS Product Specifications STANDARD EFFICIENCY PACKAGE A/C UNIT - 74 to 26 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency scroll compressor on each circuit. Dual, electrically

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information