southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Size: px
Start display at page:

Download "southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:"

Transcription

1 INSTALLATION AND OPERATION MANUAL GAS BOILERS MODELS: CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) southbend A MIDDLEBY COMPANY 1100 Old Honeycutt Road Fuquay-Varina, NC (919) FAX (919) (800)

2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION WARNING FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THAT THE OPERATOR OF THIS APPLIANCE SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER. IMPORTANT DO NOT ATTEMPT TO OPERATE THIS UNIT IN THE EVENT OF POWER FAILURE. ADEQUATE CLEARANCES MUST BE MAINTAINED FOR SAFE AND PROPER OPERATION. THE APPLIANCE AREA MUST BE KEPT FREE AND CLEAR OF COMBUSTIBLES. DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR. WARNING IMPROPER INSTALLATION. ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION. OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT CONTACT THE FACTORY. THE FACTORY REPRESENTATIVE OR A LOCAL SERVICE COMPANY TO PERFORM MAINTENANCE AND REPAIRS SHOULD THE APPLIANCE MALFUNCTION. REFER TO WARRANTY TERMS. -1-

3 IMPORTANT NOTES FOR INSTALLATION AND OPERATION WARNING: IN THE EVENT OF POWER FAILURE. NO ATTEMPT SHOULD BE MADE TO OPERATE THE APPLIANCE DURING POWER FAILURE. WARNING: IN THE EVENT OF MAIN BURNER IGNITION FAILURE. A 5 MINUTE PURGE PERIOD MUST BE OBSERVED PRIOR TO RE-ESTABLISHING IGNITION SOURCE. WARNING: IN THE EVENT A GAS ODOR IS DETECTED. SHUT DOWN EQUIPMENT AT THE MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE- WARNING DISCONNECT UNIT FROM POWER SUPPLY BEFORE CLEANING OR SERVICING APPLIANCE- WATER QUALITY STATEMENT WATER QUALITY IS THE MAJOR FACTOR AFFECTING WE PERFORMANCE OF YOUR APPLIANCE. IF YOU UNSURE OF WATER QUALITY. CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE WE WATER ANNALYZED. VOW WATER SUPPLY MUST BE TOTAL DISSOLVED SOLIDS LESS THAN 60 PPM TOTAL ALKALINITY LESS THAN 20 PPM SlLICA LESS THAN 13 PPM CHLORINE LESS THAN 30 PPM ph FACTOR WATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS HOT COVERED UNDER WARRANTY. INTENDED FOR COMMERCIAL USE ONLY NOT FOR HOUSEHOLD USE

4 INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This manual should retained for future reference. INDEX DESCRIPTION PAGE IMPORTANT MOTES 1-2 INDEX 3 DIMENSIONS AND SERVICE CONNECTIONS 4 INSTALLATION INSTRUCTIONS 5 OPERATION INSTRUCTIONS 6 PERIODIC MAINTENANCE 7 TROUBLESHOOTING 8 DESCALING INSTRUCTIONS 9 ELECTRONIC IGNITION 10 TROUBLESHOOTING ELECTRONIC IGNITION 11 IMPORTANT NOTES FOR ELECTRONIC IGNITION ELECTRONIC IGNITION 12 WIRING DIAGRAM ELECTRONIC IGNITION 13

5 DIMENSIONS & SERVICE CONNECTIONS SERVICE CONNECTIONS CW Cold Water. 3/8 copper tube EC Electric Connection: 1/2" (13 mm) conduit connection to controls. 2 Amps per compartment or DR Drain: 2" (51mm) IPS piped to open floor drain. No Solid Connection. ST Steam Take-off Connection: 3/4" (19 mm) optional to operate adjacent equipment. WD Wiring Diagram Location GC Gas Connection: 3/4" (19 mm) IPS. -4-

6 INSTALLATION INSTRUCTIONS Appliance location should have an exhaust system provided directly above the appliance to exhaust combustion generated by the Gas Boiler. FOR USE ON NONCOMBUSTIBLE FLOORS. MINIMUM CLEARANCE FROM COMBUSTIBLE AND NONCOMBUSTIBLE CONSTRUCTION, 3" ON SIDES AND FROM THE BACK. Ascertain that adequate clearance on right side of appliance is available for servicing components contained in Steamer Control Enclosure. AN OPEN GAP FLOOR DRAIN IS REQUIRES IMMEDIATELY BELOW THE APPLIANCE DRAIN. Set Appliance is place and level using spirit level. SERVICE CONNECTIONS Make service connections as indicated in Legend (Page 4). GAS INSTALLATION TO CONFORM TO LOCAL CODES OR IN THE ABSENCE 0. LOCAL CODES TO NATIONAL FUEL GAS CODE - ANSI Z LATEST EDITION IN CANADA INSTALLATION IN ACCORDANCE WITH CAN/CGA B OR.2 OR CURRENT CODE. 1. The appliance and it's individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.45 kpa). 2. The appliance must be isolated from the gas supply piping system by closing it's individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.45 kpa). ELECTRICAL GROUNDING MUST BE PROVIDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL ELECTRIC CODE. ANSI NFPA 70 - LATEST EDITION IN CANADA INSTALLATION IN ACCORDANCE WITH C.S.A. C22.1 CANADIAN ELECTRIC CODE. PART 1.

7 OPERATION INSTRUCTIONS Open manual gas shut off supply valve and if the appliance has a manual Blow Down Valve, close it. Open cabinet door and turn ON power switch located on left side. Pilot light will come on (green) and water will begin to enter Boiler and required water level will be reached in about 3 minutes. Observe water gauge glass to verify. The Dial on the gas combination control valve has 3 positions (ON-PILOT-OFF) for manual gas control of main burners and pilot. Turn DIAL on gas combination valve to PILOT. Depress Dial and light Pilot Burner located on centre main burner of Boiler. Maintain Dial in depressed position for about 30 seconds and release. Observe the Pilot Burner flame stays on. If at any time the flame should become extinguished, a 5 minute period for complete shut off Gas Supply is required before relighting. Turn DIAL to ON and burners will ignite. Steam generation will now commence and be completed in about 15 minutes. Observe that Boiler Pressure Gauge indicates steam pressure in range of psi. DAILY SHUTDOWN PROCEDURE Turn OFF power switch. Observe that Burners go off and if the appliance is equipped with Automatic Blow Down Solenoid Valve the Boiler contents water and steam will be blown out and exhausted through the appliance Drain. The Cold Water Solenoid Valve will now be activated as well. If the appliance is equipped with a manual Blow Down Valve, open it. The Gas Boiler is designed to ASME Code and approved as a steam heating boiler restricted to operate at pressures not to exceed 15 psi. DAILY STARTING PROCEDURE 1. If Boiler has a Manual Blowdown drain valve, close it. 2. Examine that pilot burner flame is on. If flame is out, a 5 minute period of complete shut off gas supply is required before relighting. 3. Turn power switch ON. COMPLETE SHUT DOWN If the appliance is not intended to be operational for a length period of time then shut it down completely. 1. If Boiler has a Manual Blowdown drain valve open it. 2. Shut OFF all power, gas and water supplies to appliance.

8 PERIODIC MAINTENANCE NOTICE: As a safety precaution, disconnect the power supply during cleaning or servicing. CLEANING 1. Keep exposed cleanable areas of unit clean at all times. 2. If water in water gauge glass is not clear and appears murky, this indicates poor water quality and will cause control failures. 3. Safety Valve should be tripped during operation once a week to assure that it functions properly. 4. If burner equipped with pressure regulator twice a year remove hex plug located at bottom of regulator remove and clean strainer. 5. Clean around burner air mixer and orifice if lint has accumulated. 6. Visually assure carry over ports are unobstructed. 7. Rinse entire unit and dry. DO NOT GET WATER in- electrical box or any electrical component.

9 TROUBLESHOOTING BURNER DOES NOT COME ON 1. Gas supply to unit is "OFF". 2. Manual shut off valve is "OFF". 3. Pilot is "OUT". 4. Power Supply is "OFF". BURNERS PRODUCE CARBON DEPOSITS 1. Wrong size orifices 2. Burner air not adjusted properly. 3. Wrong gas supply. 4. Incorrect pressure at supply. SAFETY RELIEF VALVE BLOWS 1. Defective Valve 2. Pressure too high, pressure switch require adjustment. (lower) or may be defective. WATER MOT BEING SUPPLIED TO BOILER 1. Water supply is "OFF". 2. Defective water fill Solenoid Valve. 3. Water level control clogged or defective, unable to operate fill valve. 4. Check that drain valve is closed. 5. Supply water pressure too low. ADJUSTMENTS WARNING: AT LEAST TWICE A YEAR HAVE AN AUTHORIZED SERVICE PERSON CLEAN AND ADJUST THE UNIT FOR MAXIMUM PERFORMANCE -8-

10 GAS BOILER DESCALING INSTRUCTIONS It is recommended that the boiler should be checked every day's for scale build up. Regular maintenance should Be carried out at this time. If the boiler has been descaled a new Anode should be replaced in the boiler to help extend its life. 1. With Boiler empty, close manual blowdown valve. If appliance is equipped with Automatic Blowdown, turn water supply OFF to appliance. Turn power switch ON, this will energize and close Blowdown valve. 2. Remove 3/4" pipe plug from fitting on left front of boiler. 3. Insert appropriate hose or tube through fitting and pour in (1/2) half gallon (U.S) of CLR Descaling solution. Or use the Optional Deliming assembly DPA-1 available from your dealer. 4. Replace 3/4" pipe plug securely. 5. Open water supply to appliance allowing water to fill boiler to required level. 6. Let appliance cycle, allow two hours for descaling and cleaning. DO NOT TURN STEAM ON. 7. Open both the blowdown and low water level control valves for complete drainage and close both valves. Appliance equipped with Automatic Blowdown, turn OFF power switch and open low water control valve, this will allow complete drainage. Once drained close water level control valve. 8. Turn appliance switch ON. When boiler is completely filled, turn power switch OFF, this will rinse and drain boiler. Appliance with Manual blowdown valve must be opened to drain. 9. Complete Step 8 twice to assure boiler is completely rinsed. 10. Appliance is now ready for use. -9-

11 ELECTRONIC IGNITION LIGHTING INSTRUCTION Open manual gas shut off supply valve and if appliance has a manual blow down valve, close it. Open cabinet door and turn on power switch located on left side. Pilot light will come on and water will begin to enter boiler. required water level will be reached in approximately 3 minutes. Observe water gauge glass to verify. The Dial on the gas combination control valve has 2 positions, OFF - prevents pilot and main burners gas flow. ON - permits gas to flow into the control body. Under control of power switch and intermittent pilot module, pilot and main burner gas flow is permitted. NOTE: Units are shipped with the gas control knob in the "ON" position. Gas control knob if rotated counter-clockwise is ON. To turn "OFF" turn knob clockwise. With power switch "ON" and water entering the boiler* gas will flow to pilot, spark will begin in approximately 2-3 seconds. If the pilot fails to light in 90 seconds the module will provide 100% lockout. Should this occur wait 5 minutes then turn power switch off for one minute. Turn power switch on. Once pilot is lit and the required water level has been reached the main burners will ignite. Burners will cycle to meet the steam pressure required. Daily Shut Down Procedure 1. Turn power switch OFF. 2. If unit has manual blow down valve - open it. Complete Shut Down If appliance is not intended to be operated for a lengthy period of time - shut down completely. 1. Turn off all power, gas and water supplies to appliance. 2. If unit has manual blow down valve - open it. -10-

12 TROUBLESHOOTING Pilot does not light 1. Gas supply to unit is OFF. 2. Power supply is OFF. 3. Gas control knob is OFF. 4. Dirty or loose wire connection to module - clean and/or tighten. 5. Ignitor cable, shorting out - check that not in contact with metal or damaged; may require replacement. 6. Defective control or module. 7. Unit goes into 100% lock out - turn off and try again in 5 minutes. 8. Dirty flame sensor - clean with emery cloth. 9. Cracked ceramic insulator - replace pilot burner/ ignitor sensor. 10. Too much draft. Burner does not come on 1. Pilot out. 2. Pilot may require flame adjustment. 3. Water level has not been reached in boiler. Check water supply is on, check water level control. 4. If water at proper level check relay, which energizes pressure switch and gas control. 5. Pressure switch may need to be replaced if relay is operating. 6. Gas control may also require replacement if energized but not operating.

13 WARNING Do not force the gas control knob. Use only your hand to turn the gas control knob. Never use any tool. If the gas control knob will not operate by hand the gas control should be replaced by a qualified service technician. WARNING Do not disassemble the gas control; it contains no replaceable components. Attempted disassembly or repair may damage the gas control. CAUTION Do not apply a jumper across or short the valve coil terminals. Doing so may damage the heat anticipator or electronic module. -12-

14

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416)

More information

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10 INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD,

More information

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16 INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358,

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Hot Top HHT Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002130 REV 1 IMPORTANT

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Fryer HFR Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002137 REV 1 IMPORTANT

More information

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMER MODEL: GCX-2 GCX-10

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMER MODEL: GCX-2 GCX-10 INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMER MODEL: GCX-2 GCX-10 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358, FAX:

More information

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL GPC-14/18/20 GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL GPC-18 shown with optional rinse station. NOTICE! After installation of your equipment, immediately contact your local gas supplier to obtain

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL GS, GL & GT SERIES FULLY STEAM JACKETED GAS KETTLES MODEL GS25E GS30E GL40E GS60E GL80E GT100E GT5E GT150E ML-52633 ML-52634 ML-52635 ML-52660 ML-52637 ML-52638 ML-52639

More information

MODELS: JGM, JGGM, JGT, JGTS, JGTSD, JGTSDS, JGGT, JGGTS, JTYG GRIDDLES AND JHP, JHPE HOT PLATES

MODELS: JGM, JGGM, JGT, JGTS, JGTSD, JGTSDS, JGGT, JGGTS, JTYG GRIDDLES AND JHP, JHPE HOT PLATES Jade Range LLC, A Middleby Company 2650 Orbiter Ave. Brea, CA 92821 Telephone (714) 961-2400 FAX (714) 961-2550 MODELS: JGM, JGGM, JGT, JGTS, JGTSD, JGTSDS, JGGT, JGGTS, JTYG GRIDDLES AND JHP, JHPE HOT

More information

Owner s Guide Installation & Operation

Owner s Guide Installation & Operation Owner s Guide Installation & Operation Char Broiler HCH Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002134 REV

More information

JADE TACO RANGES MODEL: JTR and JTRB Series JADE STOCK POT RANGES MODEL: JSP Series

JADE TACO RANGES MODEL: JTR and JTRB Series JADE STOCK POT RANGES MODEL: JSP Series Jade Range LLC, A Middleby Company 2650 Orbiter Ave. Brea, CA 92821 Telephone (714) 961-2400 FAX (714) 961-2550 JADE TACO RANGES MODEL: JTR and JTRB Series JADE STOCK POT RANGES MODEL: JSP Series INSTALLATION,

More information

CINCINNATI, OH USA

CINCINNATI, OH USA INSTRUCTION MANUAL Part No. 89731 Revised October 1997 CINCINNATI, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier.

More information

Using it in an enclosed space can kill you.

Using it in an enclosed space can kill you. 38 X 56 GAS FIRE PIT - OWNER S MANUAL Carlisle Chat Fire Table Base Model # 00GBC7 (6877B) Fits 6877A Carlisle Chat Fire Table Top For Propane and *Natural Gas (*See Page 7) Certified to CSA International

More information

User s Information Manual Models: 45, ,000 Btu/hr

User s Information Manual Models: 45, ,000 Btu/hr SBR-USER_100161678_2000017137_Rev C User s Information Manual Models: 45,000-260,000 Btu/hr If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,

More information

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only. 110 Cup (55 Cup Raw) Gas Rice Cooker Intertek 5010781 Conforms to ANSI STD Z83.11-2016 Model: 177GRCLP, 177GRCNAT 12/2018 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL VHX24, VHL2, VHL3 & VH3616 SERIES FOOD STEAMERS & MHB24 SERIES STEAM GENERATORS MODELS VHX24E VHX24E5 VHX24G VHX24G5 VHX24D VHX24D5 VHL2G VHL3G VHL2E VHL3E VHL2D VHL3D MHB24E

More information

Jade Salamander Broilers Model: JSB Series

Jade Salamander Broilers Model: JSB Series Jade Range LLC, A Middleby Company 2650 Orbiter Ave. Brea, CA 92821 Telephone (714) 961-2400 FAX (714) 961-2550 Jade Salamander Broilers Model: JSB Series Installation, Operation and Maintenance Instructions

More information

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D FOR YOUR SAFETY FOR YOUR SAFETY IF YOU SMELL GAS: DO NOT STORE OR USE GASOLINE 1. OPEN

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1000T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

Statement of Responsibilities

Statement of Responsibilities Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired

More information

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A Owner s Manual Model number FMPPC2A Series number 890 FMI BRANDS INC. 309-19133 26th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free 1-888-514-1663 Fax 1-888-797-9931 Owner & Safety Manual Model number FMPPC2A,

More information

Dashley Outdoor Fire Table

Dashley Outdoor Fire Table Dashley Outdoor Fire Table MODEL N0. 085-557-8 L-FT047PST-F ASSEMBLY INSTRUCTIONS Toll-free 888 670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this

More information

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler Gas boiler UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM. INSTALLER MUST REVIEW

More information

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS CSA Model 98300 DRF01000 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1.

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

INSTALLATION & OPERATION MANUAL GAS CHARBROILERS

INSTALLATION & OPERATION MANUAL GAS CHARBROILERS INSTALLATION & OPERATION MANUAL GAS CHARBROILERS MODELS VCCB25 VCCB36 VCCB47 VCCB60 VCCB72 VCCB47 SCB25 SCB36 SCB47 SCB60 SCB72 SCB47 ITW Food Equipment Group, LLC 3600 North Point Blvd. Baltimore, MD

More information

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F Owner s Manual Model number FMPPC2F Series number 863 2017 FMI Brands Inc. Patent Pending D.863.000.V3 FMI BRANDS INC. 107 19052 26 Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free 1-888-514-1663 Fax 1-888-797-9931

More information

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS AND OWNER S MANUAL OPERATING INSTRUCTIONS AND OWNER S MANUAL MR. HEATER READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has

More information

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F Owner s Manual Model number FMPPC2F Series number 863 D.863.000.V0 FMI BRANDS INC. 309-19133 26th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free 1-888-514-1663 Fax 1-888-797-9931 Owner & Safety Manual Model

More information

Operator s Manual CAYENNE GAS COUNTERTOP CHAR BROILER ENGLISH

Operator s Manual CAYENNE GAS COUNTERTOP CHAR BROILER ENGLISH NGLISH CAYNN GAS COUNTRTOP CHAR BROILR Thank you for purchasing this Vollrath Counter Top Cooking quipment. Before operating the equipment, read and familiarize yourself with the following operating and

More information

Stone Hearth Pizza Dome Oven

Stone Hearth Pizza Dome Oven Stone Hearth Pizza Dome Oven INSTALLATION AND OPERATION MANUAL GAS-FIRED OVEN CAUTION This oven MUST be seasoned before initial use The seasoning procedure takes 6 days, running the oven for at least 8

More information

CYLINDER NOT INCLUDED

CYLINDER NOT INCLUDED OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # HS125NG / MH125LP / HS125LP READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL EF SERIES ECONOFRY GAS FRYERS MODEL EF3 EF4 EF5 ML-52099 ML-114943 ML-114944 MODEL EF3 For additional information on Vulcan-Hart or to locate an authorized parts and service

More information

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART # INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED

More information

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

USE AND CARE GUIDE WARNING WARNING WARNING WARNING USE AND CARE GUIDE Item No.: HF11501AA USE PROPANE GAS ONLY! -Do not store or use gasoline or other flammable vapors in the vicinity of this or any other appliance. - Service must be performed by a qualified

More information

GAS FIRED STEAMER Models SX-34GCR and SX-55GCR

GAS FIRED STEAMER Models SX-34GCR and SX-55GCR IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment: Model #: Serial #: Owner s Manual Date Purchased: GAS FIRED STEAMER Models SX-34GCR

More information

USER MANUAL Gas Countertop Charbroilers

USER MANUAL Gas Countertop Charbroilers Gas Countertop Charbroilers REVISED 2/209 382799 LAVA BRIQUETTE MODELS: 35CLCPG5NL, 35CLCPG24NL, 35CLCPG36NL, 35CLCPG48NL, 35CLCPG60NL, 35CLCPG72NL Congratulations on your purchase of Cooking Performance

More information

MG SERIES GAS OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE M24G M36G MODELS

MG SERIES GAS OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE M24G M36G MODELS MG SERIES GAS OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24G M36G Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0307 Rev F (11/17) 2017 - Market Forge Your

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........

More information

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2E-1

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2E-1 Owner s Manual Model number FMPPC2E-1 Series number 401 FMI BRANDS INC. 107 19052 26 Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free 1-888-514-1663 Fax 1-888-797-9931 Owner & Safety Manual Model number FMPPC2E-1,

More information

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS S150 & S300 CONSTRUCTION HEATERS Rev: 2.7.2 August 15, 2008 SERVICE AND MAINTENANCE MANUAL No. 934-6637 PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS A DIVISION OF HAUL-ALL EQUIPMENT LTD. 4115-18 Avenue

More information

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS CSA Model98900 DRS02403 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas:

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE PFS APPROVED FOR NATURAL GAS OR PROPANE GAS Z21.50-2014 If your plans do not allow for the venting system as outlined previously in the installing chimney/vent

More information

CBO-750 HYBRID-R OVEN Instructions Manual

CBO-750 HYBRID-R OVEN Instructions Manual CBO-750 HYBRID-R OVEN Instructions Manual ELECTRICAL DIAGRAM IS LOCATED BEHIND FRONT PANEL THIS OVEN MAY BE OPERATED OUTDOORS. ELECTRICAL DIAGRAMS ARE LOCATED BEHIND FRONT PANEL. KEEP THIS MANUAL FOR FUTURE

More information

LUMINOUS A PATIO HEATER LIKE NO OTHER

LUMINOUS A PATIO HEATER LIKE NO OTHER LUMINOUS A PATIO HEATER LIKE NO OTHER Manual for Installation, Operation & Maintenance BPL-HAB20 BPL-HAB40 BPL-HAB50 DANGER If you smell gas: 1. Shut off gas to appliance. 2. Extinguish any open flame.

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS CSA Model 99000 ARL00100 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1. Shut off gas to the

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model99000 BRH01000 DANGER If you smell gas: 1. Shut off gas to the

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Propane gas CSD-1 Control System Part Number 550-110-682/0304 Please read this page first Hazard definitions To the installer... The following terms

More information

Riaza Tablemount Fire Bowl. Item# Model# HYUTT DANGER If you smell gas: 1. Shut off gas to the appliance.

Riaza Tablemount Fire Bowl. Item# Model# HYUTT DANGER If you smell gas: 1. Shut off gas to the appliance. Riaza Tablemount Fire Bowl Item# 50224 Model# HYUTT15001-2 DANGER If you smell gas: 1. Shut off gas to the appliance. 3. If odor continues, keep away from the appliance and immediately call WARNING Do

More information

GAS COOKTOP INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING If the information

More information

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. Operating Instructions and Owner s Manual READ INSTRUCTIONS CAREFULLY: Read and follow all instructions.

More information

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP) USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP) DANGER - IF YOU SMELL GAS: I) Shut off the gas supply to the appliance at its source. 2) Extinguish any

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN

More information

TERRACE AND PATIO HEATER

TERRACE AND PATIO HEATER TERRACE AND PATIO HEATER USER INSTALLATION AND OPERATION GUIDE INDEX General and specifications.1,2 Security and caution.. 3 Tools and accessories required 5 Assembly instructions 5-7 Operation (Lighting

More information

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas glor sun The Original Outdoor Patio Heater Manufactured by INFRARED DYNAMICS, INC. Yorba Linda, CA 92886 U.S.A. Tel: (714) 572-4050 Fax: (714) 572-6093 Toll-Free: (888) 317-5255 www.infradyne.com SPECIFICATIONS:

More information

OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T

OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T INSTALLATION INSTRUCTIONS (for Heater Models SC18T-1,

More information

TERRACE AND PATIO HEATER

TERRACE AND PATIO HEATER TERRACE AND PATIO HEATER USER INSTALLATION AND OPERATION GUIDE INDEX General and specifications.11 Security and caution.. 12, 13 Tools and accessories required 13 Assembly instructions 14,15 & 16 Verifying

More information

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP) USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP) DANGER - IF YOU SMELL GAS: I) Shut off the gas supply to the appliance at its source. 2) Extinguish any

More information

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 781-2777 Fax: (314) 781-3636 Installation and Operating Instructions 2M-Z1351 Rev. B 4/23/04 STAR-MAX GAS GRIDDLES

More information

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83. THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.7 2011 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL Manual Griddles: Radiant Charbroilers: Hot Plates: 177AG24MG 177AG36MG 177AG24RC 177AG36RC 177AGR212 All equipment manufactured

More information

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING By CNP INDUSTRIES, INC. P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721 INSTALLATION INSTRUCTIONS GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D IMPORTANT: Before beginning installation please read these

More information

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES INSTALLATION AND OPERATION GUIDE INDEX General and specifications 1 Security and caution.. 1,2 Tools and accessories required 2 Assembly instructions 3 Verifying

More information

Statement of Responsibilities

Statement of Responsibilities Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and

More information

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS 1128 Sherborn Street Corona, CA 92879-2089 (951) 281-1830 (951) 281-1879 IPC SERIES PASTA COOKER All Imperial Mfg. Co. equipment is manufactured

More information

USE AND CARE GUIDE PEDESTAL FIREBOWL

USE AND CARE GUIDE PEDESTAL FIREBOWL DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department. WARNING

More information

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMERS MODELS: GSX-5HE GSX-7HE GSX-10HE GSX-16HE

INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMERS MODELS: GSX-5HE GSX-7HE GSX-10HE GSX-16HE INSTALLATION AND OPERATION MANUAL GAS FIRED STEAMERS MODELS: GSX-5HE GSX-7HE GSX-10HE GSX-16HE CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE:

More information

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on

More information

Multi-Function Cooktop

Multi-Function Cooktop INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............

More information

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV GAS -FIRED VENTED ROOM HEATERS MODEL 61TV INSTALLATION MANUAL NEW BUCK CORPORATION WARNING: Improper installation, adjustment, alteration,service or maintenance can cause injury or property damage. Refer

More information

Stoneridge Fire Pit High Dining Table Assembly Instruction

Stoneridge Fire Pit High Dining Table Assembly Instruction Stoneridge Fire Pit High Dining Table Assembly Instruction Item# L-DN1773SST-D-T WARNING: For Outdoor Use Only. DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame.

More information

Installation/Operating Instructions

Installation/Operating Instructions Installation/Operating Instructions Models: 4072-180 24 NG 4072-182 30 NG Outdoor Hearth Kit DO NOT DISCARD INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this

More information

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

USER S INFORMATION MANUAL (2,4)SG13B

USER S INFORMATION MANUAL (2,4)SG13B USER S INFORMATION MANUAL (2,4)SG13B Series Gas Heating/Electric Cooling Package Unit Congratulations......your outdoor heating/cooling package unit is a valuable piece of equipment, designed and manufactured

More information

AXIS OUTDOOR HEATER. Owner s Manual DANGER WARNING

AXIS OUTDOOR HEATER. Owner s Manual DANGER WARNING AXIS OUTDOOR HEATER DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call your gas supplier or

More information

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB Star Manufacturing International Inc. 10 Sunnen Drive St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 Installation and Operating Instructions 2M-Z20327 Rev. A 10/05/15 ULTRA-MAX GAS RADIANT

More information

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18

INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG. Page 1 / 18 INSTALLATION, OPERATION AND SERVICE MANUAL GAS COOKER MODEL CPG Page 1 / 18 CHAP 1 - INSTRUCTIONS TO PREVENT ACCIDENTS Keep this manual carefully to be able to refer to it in every case of need. Keep appliance

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not

More information

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners 1 1. General Installation Information (to be completed by technician) Date installed: Location (city & state): Cleaner s name: National Board number (boiler): Installed by (company): Installed by (technician):

More information

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.), Hanover Outdoor Furniture IMPORTANT If you have any problems with this product (missing or damaged parts, assembly issues, etc.), PLEASE DO NOT RETURN TO THE RETAILER/STORE from where you purchased the

More information

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS USERS INFORMATION MANUAL FOR GAS FIRED BOILERS CATALOG NO.: 2000.52G Effective: 06-01-00 Replaces: 07-01-94 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........

More information

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas Heat/Electric Cooling Units Owner's Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK. FIRE OR EXPLOSION Failure to follow this warning could result in personal injury,

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge

More information

INSTALLATION & SERVICE MANUAL

INSTALLATION & SERVICE MANUAL GAS-FIRED WATER HEATER If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. INSTALLATION & SERVICE MANUAL

More information

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS:

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: ACGS-30 ACGS-40 ACCUTEMP PRODUCTS, INC. 8415 North Clinton Park Dr. Fort Wayne, IN 46825 800 210-5907 Office 260 493-0415 Fax www.accutemp.net PART

More information

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit Packaged Gas/Electric Units Owner s Guide to Operating and Maintaining Your Gas/Electric Unit ELECTRICAL SHOCK HAZARD. FIRE OR EXPLOSION HAZARD Disconnect power at fuse box or service panel before performing

More information

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,

More information

Owner s Manual. 36" Square Gas Fire Pit Model#SRGF11610 DANGER WARNING. WARNING: For Outdoor Use Only.

Owner s Manual. 36 Square Gas Fire Pit Model#SRGF11610 DANGER WARNING. WARNING: For Outdoor Use Only. TM 36" Square Gas Fire Pit Model#SRGF11610 DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame. 3. If odor continues, keep away from the appliance and immediately call

More information

Repeat procedures for other side.

Repeat procedures for other side. Repeat procedures for other side. ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model 98900 Printed in China DANGER

More information

PRO SERIES GAS FRYERS OWNER S MANUAL

PRO SERIES GAS FRYERS OWNER S MANUAL PRO SERIES GAS FRYERS OWNER S MANUAL MODELS: PF-1 PRO-FRYER, PF2 DUAL PRO-FRYER REVISED OCTOBER, 2009 *PLEASE RETAIN FOR FUTURE REFERENCE This appliance has been tested according to ANSI Z83.116-2009/CSA1.86-2009.

More information

INSTALLATION OPERATION AND SERVICE MANUAL

INSTALLATION OPERATION AND SERVICE MANUAL INSTALLATION OPERATION AND SERVICE MANUAL VENTED DECORATIVE GAS APPLIANCE/ DECORATIVE COAL/LOG SET B30/B31/B32/B33/B34 PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE. ALWAYS

More information

INSTALLATION OPERATION AND SERVICE MANUAL

INSTALLATION OPERATION AND SERVICE MANUAL INSTALLATION OPERATION AND SERVICE MANUAL THE OLD SALEM COLLECTION VENT FREE REGENCY COAL BASKET complies with ANSI Z21.11.2 THIS ONLINE MANUAL IS FOR PLANNING PUPOSES ONLY. CAREFULLY READ BEFORE PURCHASING.

More information