Model: R20C/H. Submittal B. Replacement R20 Series Horizontal PTACs & PTHPs. Replacement for (Chassis Option - A):
|
|
- Shavonne Moore
- 5 years ago
- Views:
Transcription
1 Submittal Replacement R0 Series Horizontal PTACs & PTHPs Model: R0C/H R 0 0 B Model Series: [R0= Repl.] Operation: [C=Straight Cool] [H=Heat Pump] Compressor: Special Rev: Cooling Capacity: [09=9,000 Btuh] [1=11,000 Btuh] [1=1,700 Btuh] [18=1,600 Btuh] (Straight Cool Only) Voltage: [A=11V/] (09 Straight Cool Only) [D=08-0V/ (Std)] [E=6-77V/] Auxilary Heat: [*See Specifications- Electrical Data] [0=None (Std)] *[=kw@0v] or [=kw@6v] *[=kw@0v] or [=kw@6v] or [=1kW@11V] *[=kw@0v] or [=kw@6v] *[=kw@0v] or [=1.kW@11V] Cond. Coil Option: [A=Standard (Al/Cu)] [B=Coated (Al/Cu)] Chassis Option: [A=Standard] [D=Fedders CMEO Unizone (R80)] Air Options: [A=Bottom Return, No Fresh Air (Std)] [B=Bottom Return, Motorized FA Damper] [C=Front Return, No Fresh Air] [D=Front Return, Motorized FA Damper] Product Revison: Controls Options: [See Accy list for Hyd Vlv & T stat] [0=Unit Mount w/ Electric/NO Heat] [1=Vac T stat w/ Electric/NO Heat] [=Unit Mount w/ Hyd Ht (Line V Vlv)] [=Vac T stat w/ Hyd Ht (Line V Vlv)] [= Unit Mount w/ Hyd Ht (V Vlv)] [=Vac T stat w/ Hyd Ht (V Vlv)] Replacement for (Chassis Option - A): Adirondack Aire CH/RM, Applied Comfort SCEA/SCHA, Climate Master 70-, Friedrich 70/70, Comitale CTPI, Cool Heat RM, Ice Air RSCM/A/RSZ, Ice Cap RSZ, Islandaire CM/RM/SC, Simon-Aire SSZ, TPI Ra-Matic, Weather Twin RM/S/ SC, Zoneaire RM/SC. Replacement for (Chassis Option - D): Comitale CFOO, Fedders CMEO Unizone, Ice Cap RSU, Islandaire UN, Mueller/ Worthington Climatrol, Retroair R80 Number of Units Ordered Made in the USA Approved: Reviewed: Contact: Address: Phone: Unit Tag # REVISON By: Approval 1
2 QTY Ordered Indicate the quantity of field installed accessories, required for each unit Description Thermostat, Single-Stage, 1-Heat/1-Cool, Vac, Programmable, ICM, Manual Changeover (PN ) Thermostat, -Stage, -Heat/-Cool, Vac, Programmable, ICM, Manual Changeover (PN ) Thermostat, Single-Stage, 1-Heat/1-Cool, Vac, Programmable, ICM, Auto Changeover (PN ) Thermostat, T9000, Wireless, Battery, Single Stage, 1-Ht/1-Cl, /- Prog, MCO [# also required] (PN ) Remote Control Node, T9000, Printed Circuit Board, Wireless, Vac, 1/unit req d [# also required] (PN ) Isolation Ball Valve, 1/, Sweat Connections (PN ) Kit, Cabinet Assembly, White Pearl, Aluminum Supply Air Louver, w/ Kick-plate & Control Door, R0 (PN ) Kit, Wall Sleeve & Louver, Architectural Aluminum Outdoor Louver, R0, 10/1/1/16/18 Depths (PN [ / / / / 6 ]) Kit, Hydronic/Steam Coil, 1-Row, Al-Cu, Left-Handed Piping, R0 (PN 00019) Kit, Hydronic/Steam Coil, 1-Row, Al-Cu, Right-Handed Piping, R0 (PN 00011) Kit, Aquastat, Hydronic Heat, Hot Water Sensor-Relay [Energizes Fan] (PN 00008) Kits, Water Valves, w/ Actuator, /-Way, Line/Vac, NO/NC, Sweat (Several Kits Available-Consult Factory) Job-Guide Specifications Standard Warranty: 1 Year - Parts & Year - Compressor High Pressure Switch with Integral Compressor Lockout Microprocessor Control Board Diagnostic LED Codes with Test Mode Thermally-protected PSC fan motors Indoor Coil Freeze & Anti-Short Cycle (Compr), Protections Single Stage Heating Operation (w/ or w/o Electric Heat) DOE Performance Qualified & Listed ETL-US & Canada Listed for Safety to UL8 Standard Reversing Valve Energized in Cooling (Heat Pumps) Meets ASHRAE for Replacement Efficiencies Operating Range Mode OD Amb. Temp ID Amb. Temp Cooling Max 10ºF (1ºC) DB 80ºF (7ºC) DB Min ºF (0ºC) DB 60ºF (19ºC) DB Heating Max 7ºF (ºC) DB 80ºF (7ºC) DB Min 0ºF (.ºC) DB 6ºF (18ºC) DB Electrical Plug Configurations NOTICE: Due to ongoing product development; design, specification and performance data listed within this submittal document are subject to change without notice. For the most current performance data, please refer to RetroAire listings of certified products in the DOE directory, or consult the factory. ECR International, INC. 01 Dwyer Avenue Utica, NY info@retroaire.com FAX RETRO Sales: Customer Service : 1 (800) -96
3 Specification and Performance Model: R0C/H Product Description RetroAire Replacement Packaged Terminal Air Condition/ Heat Pumps units are straight cooling (PTAC) or heat pump systems (PTHP). Both PTAC and PTHP configurations fit wall sleeves. Heat pumps (PTHP) operate in mechanical heat mode down to outdoor temperature of 0 F (. C). Below 0 F (. C) heating is accomplished by auxiliary heat option. ETL listed to UL8, CAN/CSA C. No Retroaire PTAC/PTHP R-10A refrigerant. High-efficiency rotary compressors. Two fan speeds. Positive condensate re-evaporation. PTAC/PTHP units are available in nominal sizes of 9,000 Btuh, (.6kW) 1,000 Btuh (.kw) or 1,000 Btuh (.kw). PTAC units (straight cooling only) are available at 18,000 Btuh (.kw). Coefficient of performance (COP) ratings.0 for heat pumps. Standard Controls And Components Construction Chassis constructed of 0 gauge galvanized steel. Condenser baffle options accommodate extended wall sleeve applications. (Consult manufacturer). Powder-coated condenser and evaporator drain pan. Foam strip seal for supply air duct. Weather strip insulation. Air Systems Thermally-protected motors PSC type. Indoor fan forward curved type, directly mounted to motor shaft. Unit mount controls include field selection switch to control indoor fan by either cycling with compressor operation or continuously with unit. Condensate Removal Outdoor fan incorporates condensate slinger ring. Condensate is thrown onto coil, where it evaporates. Thermostatic drain pan valve for condensate elimination when outdoor temperature drops below 60 F (1 C) (heat pump units only). Controls Unit-mounted operating controls include thermostat, fan speed control, heat/cool switch, fan cycle switch, fresh air switch (if equipped). Use of optional 1-stage or -stage thermostat. stage thermostat is capable of activating emergency heat if auxiliary heat source is available. Low ambient protection see "Microprocessor control board" for details. Ability to control a normally-open or normally-closed motor valve switch (on hydronic heat units only). Valve controls must be ordered for V or line voltage. All hydronic heat units include molex plugs for connection of hydronic valve motor. Optional wall thermostat controls include fan speed control and fresh air switch (if equipped). Equipped with manual reset high pressure switch which prevents abnormal high pressure operation. Microprocessor Control Board Universal control board used in straight cooling, electric resistance heat, hydronic heat, or cooling/heat pump applications. Random start timer prevents multiple units from simultaneous startups after power interruption or on initial power-up. Fan purge fan remains on for 60 seconds after heat/cool is satisfied. Anti-short-cycle compressor protection prevents compressor from rapid cycling. Freeze-protection prevents evaporator coil freeze up. Low ambient lockout prevents compressor operation in outdoor temperatures less than 0 F (. C). (On PTHP units supplied with unit-mounted control, control causes automatic changeover to auxiliary heat, if installed.) Test operation all timers are temporarily suppressed to allow ease of testing or troubleshooting. Control board LED provides self-diagnostic troubleshooting codes, see Installation, Operation & Maintenance Manual for Sequence of Operation.
4 PRODUCT DESCRIPTION - CONTI. Manufacturer Installed Options (Consult manufacturer) 6V (1 and 1 only) 11V (09 Model Only) Corrosion-resistant coil option used for seacoast and harsh-environment usage; coated aluminum fin/copper tube condenser coil. Motorized fresh-air damper Supplemental electric heat Hydronic heat controls Front air intake Field-Installed Accessories Hydronic heat coil assembly is shipped loose for field installation. Wall thermostat digital 1-stage or -stage available. Wall sleeves, louvers, and cabinets. Aquastat - delays fan start-up until coil reaches 100 F (8 C) to virtually eliminate "cold" blow condition. Hydronic control valve, water way & way. Hydronic control valve, steam way. Hydronic Isolation valve, 1/ in sweat connection.
5 PRODUCT FEATURES Indoor Coil Freeze Protection (standard) This feature will prevent the indoor coil from freeze up in the cooling mode. Indoor coil freeze up can occur due to a dirty air filter, restricted or poor air flow, low refrigerant charge or low room or outdoor temperatures. This in turn can cause compressor damage. Should a freeze condition be detected, the compressor and outdoor fan will be switched off for a minimum of three minutes until the freeze condition is satisfied. During this time the indoor fan will continue to run to aid in the defrost process. Condensate Removal (standard) The RetroAire replacement unit (cooling operation) is designed to eliminate condensate by slinging it onto the outdoor coil. Condensate drains through the bulkhead to the area near the outdoor fan. As part of its normal operation, the unit will produce condensate and collect it in the base pan of the unit. There it is picked up by the outdoor fan slinger ring and deposited onto the condenser coil. During the cooling season, this improves the unit s efficiency by maintaining reduced refrigeration system pressures. Base pan has overflow notches-if too much condensate is produced notches allow condensate to flow out of the base pan and into the wall sleeve out of the building. Thermostatic Drain Pan Valve (standard on heat pump units) On heat pump models (PTHP), condensate can accumulate in the outdoor drain pan during the heat pump cycle. PTHP units include a thermostatic drain valve that opens when outdoor temperatures fall below 60 F (1 C). When the drain valve opens, condensate flows from the drain pan onto the bottom of the wall sleeve, where it drains to the outside. This keeps the base pan free of condensate water, which could otherwise freeze during colder outdoor temperatures. Random Start Feature (standard) The random start feature is initiated on initial power-up or after a power interruption. The controller adds a random time delay (from 10 seconds) on start-up, preventing the compressor from starting. This staggers the starting of multiple units in a single facility, preventing a large surge that might occur if all units started at the same time. Anti-Short Cycle Timer (standard) The microprocessor control uses this timing to prevent shortcycling of the compressor. When the compressor cycles off on a heating or cooling call, the controller starts a 180-second timer. The compressor will not be allowed to start until this time has elapsed. On initial power-up or after a power failure, this timing occurs after the random start timing. Power Cord With Integral Safety Protection (standard) All PTAC/PTHP units rated 0V or less are equipped with a power cord with integral safety protection as standard. Providing personal shock protection as well as arcing and fire prevention, the device is designed to sense any damage in the line cord and disconnect power before a fire can occur. Tested in accordance with Underwriters Laboratories, the cord set also offers a unique passive operation, meaning the unit does not require resetting if main power is interrupted. Heat Pump Heat pump units are Limited Range and should be equipped with back-up electric resistance or hydronic heat. Limited Range heat pumps are designed to operate when outdoor temperatures are between 7 F( C) and 0 F(. C) and with a maximum indoor temperature of 80 F(6.6 C). The unit is equipped with a reversing valve that is energized for cooling and de-energized in heating mode. Electric heating or hydronic heat will operate using the on-board control logic below the operating conditions of the heat pump. Hydronic Heating (optional) An optional hydronic heat package may be selected in lieu of electric heat. Heating operation is essentially the same as that of units with electric heat. Aquastat Connection (optional) All replacement PTAC/PTHP's with hydronic heat are supplied with a standard line volt Aquastat connection. The field installed Aquastat delays the fan operation until the hydronic coil reaches a temperature of 100 F (8 C). Motorized Fresh Air Damper (optional) The optional motorized fresh air damper allows fresh air into the space to be conditioned. When the Fresh Air switch is in the "YES" position the damper door is open and allows fresh air into the space. This feature is only available when the indoor fan is on. When the damper door switch is in the "NO" position, the damper door is closed and does not allow air in the space. Optional Wall-Mounted Thermostats Thermostats compatible with your PTAC/PTHP unit: Select part number from the latest RetroAire price list for this option. This is a single stage, cool/heat, thermostat that can be used in all RetroAire cooling, heating or heat pump applications. The thermostat has an adjustable setpoint range of between F(7 C) and 9 F( C). For heat pumps another option is part number This is a stage heat/cool thermostat which allows for emergency heat. Selecting a thermostat (by others) When selecting a thermostat, choose a single stage heat/cool, v thermostat. Straight cooling with electric heat or hydronic heat, select a thermostat that is compatible with a cooling/electric heat system. Thermostat should have R, Y, W and G terminals. Heat pump with electric heat (PTHPs), select a thermostat that is compatible with cooling/single-stage heat/heat pump system. Thermostat should have R, Y, O and G terminals. RetroAire units are single stage heating only. The electric heat and heat pump will not operate simultaneously.
6 ELECTRICAL PERFORMANCE R0C09 &R0H09 - Electrical Data Power Supply Compressor ID Fan Motor OD Fan Motor Electric Heat Unit Electrical Ratings Voltage Min V RLA LRA FLA Hp FLA Hp Htr # Htr V Htr W Htr A TCA THA MCA MOCP Power 11V/ N/A P *08/0V/ **08/0V N/A P 1 6-1P 0 6-0P 6-0P 0 6-0P N/A P 6V/ * Toshiba Compressors **Tecumseh Compressors N/A P P P P R0C1 & R0H1 - Electrical Data Power Supply Compressor ID Fan Motor OD Fan Motor Electric Heat Unit Electrical Ratings Voltage Min V RLA LRA FLA Hp FLA Hp Htr # Htr V Htr W Htr A TCA THA MCA MOCP Power *08-0V/ **08/0V/ 6V/ N/A P 1 6-1P 0 6-0P 6-0P 0 6-0P N/A P 1 6 1P 0 6 0P 6-0P P N/A P P P P * Toshiba Compressors **Tecumseh Compressors Note: The listed THA value is the highest of both heating methods - heat pump & electric heat NOTICE: Due to ongoing product development; design, specification and performance data listed within this submittal document are subject to change without notice. For the most current performance data, please refer to RetroAire listings of certified products in the DOE directory, or consult manufacturer. 6
7 ELECTRICAL PERFORMANCE R0C1 & R0H1 - Electrical Data Power Supply Compressor ID Fan Motor OD Fan Motor Electric Heat Unit Electrical Ratings Voltage Min V RLA LRA FLA Hp FLA Hp Htr # Htr V Htr W Htr A TCA THA MCA MOCP Power N/A P P *08-0V/ **08-0V/ V/ * Toshiba Compressors **Tecumseh Compressors P P P N/A P P P P P N/A P P P P R0C18 - Electrical Data Power Supply Compressor ID Fan Motor OD Fan Motor Electric Heat Unit Electrical Ratings Voltage Min V RLA LRA FLA Hp FLA Hp Htr # Htr V Htr W Htr A TCA THA MCA MOCP Power N/A P P 08-0V/ V/ P 6-0P 0 6-0P N/A N/A 7-0P P N/A N/A N/A N/A N/A N/A N/A Note: The listed THA value is the highest of both heating methods - heat pump & electric heat NOTICE: Due to ongoing product development; design, specification and performance data listed within this submittal document are subject to change without notice. For the most current performance data, please refer to RetroAire listings of certified products in the DOE directory, or consult manufacturer. 7
8 ELECTRICAL PERFORMANCE Model Hydronic Coil Code Part Number Air Entering Dry Bulb Air Entering Wet Bulb Air Entering Flow Rate F C F C CFM m^/ min R R0 C/H Hydronic Heat Water Flow Water Entering Capacity GPM LPM F C Btu/h kw Pressure Drop ft HO m HO Water Leaving Water Delta F C F C , , , , , , , , , , , , , , , ,
9 PERFORMANCE DATA Models R0C R0C 09 R0C 1 R0C 1 Voltage Performance Data - Cooling Cooling Capacity EER Sensible Heat Ratio Indoor Air Flow Fresh Air Inlet Flow Outdoor Sound Level Shipping Weight Btuh (kw) CFM (L/S) CFM (L/s) dba lbs (Kg) A 11 0 (07.7) 9000 (.7) 9.0 D 08/ (16.) E (.8) (07.7 D 08/ (.) 0 (16.) E (.) 0 (07.7) D 08/0 00 (188.8) 100 (.) E 6 0 (1.) (17) 7 10 (6.) 0 () (6.) 60 (8) (6.) R0C 18 D 08/ (.6) (179.) 9 () (6.) Performance Data - Heating Models R0H Voltage Cooling Capacity EER Indoor Air Flow Cooling Heating Capacity COP Indoor Air Flow Heating Sensible Heat Ratio Fresh Air Flow Outdoor Sound Level Btuh (kw) CFM (L/S) Btuh (kw) CFM (L/S) CFM (L/S) dba Shipping Weight lbs (Kg) R0H 09 D 08/ (.7) (16.) 800 ( (189) E (.8) (07.7) 9100 (.7) 0 (1) 0.79 (17) 7 R0H 1 D 08/0 0 (16.) 00 (189) 1100 (.) (.).6 E 6 00 (188.8) 0 (1) () (6.) R0H 1 D 08/0 100 (.) (188.8) 1800 (.) 0 (1). E (.1) (1.) 100 (.) 00 (6) (8)
10 R0 C/H Chassis Fresh Air Switch (FAS) Fan Speed Switch (FSS) Fresh Air Switch (FAS) Thermostat Remote Mount Fan Speed Switch (FSS) System Switch (SS) Line Cord High Pressure Switch (HPS) reset Rating Plate Electrical Diagram Fan Cycle Switch (FCS) Aquastat W/ Jumper MTR Valve Unit Mount R0 C/H Chassis - Dimensions Dimensions in [ ] are in mm 10 Adjustable Weather Angle Dimension "A" 8 /8 7 7/8 9 11/16 (1) 8 () Dimension "B" 9 1/ 10 1/ 8 7/16 (1) 10 1/8 () Dimensions are calculated without foam gaskets. (1) Standard position Factory installed. () Position for Climate Master 70 and 70.
11 R0 C/H Wall Sleeve - Dimensions Wall Depths (A) (B) (C) 10" 1 1/" 8" 10" 1" 1 1/" 8" 1" 1" 1 1/" 8" 1" 16" 1 1/" 8" 16" 18" 1 1/" 8" 18" Top View Outside View R0 C/H Cabinet - Dimensions [Part #000116] 11
12 R0 C/H Misc. Product Data Operating Range Mode OD Amb. Temp ID Amb. Temp Cooling Max 10ºF (1ºC) DB 80ºF (7ºC) DB Min ºF (0ºC) DB 60ºF (19ºC) DB Heating Max 7ºF (ºC) DB 80ºF (7ºC) DB Min 0ºF (.ºC) DB 6ºF (18ºC) DB Replacement for (Chassis Option - A): Adirondack Aire CH/RM, Applied Comfort SCEA/SCHA, Climate Master 70-, Friedrich 70/70, Comitale CTPI, Cool Heat RM, Ice Air RSCM/A/RSZ, Ice Cap RSZ, Islandaire CM/RM/SC, Simon-Aire SSZ, TPI Ra-Matic, Weather Twin RM/S/ SC, Zoneaire RM/SC. Replacement for (Chassis Option - D): Comitale CFOO, Fedders CMEO Unizone, Ice Cap RSU, Islandaire UN, Mueller/ Worthington Climatrol Electrical Plug Configurations ECR International, INC. 01 Dwyer Avenue Utica, NY info@retroaire.com FAX RETRO Sales: Customer Service : 1 (800) -96
Specifications and Performance
R35C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh 2.6 3.5 4.4 5.3 kw Heat Pump Nominal Capacities 9,000
More informationSpecifications and Performance
R45C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) Straight Cooling Nominal Capacities 9,000 12,000 15,000 18,000 Btuh The Right Fit for Comfort 2.6 3.5 4.4 5.3 kw Heat
More informationR21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities
R21C Packaged Terminal Air Conditioner (PTAC) The Right Fit for Comfort Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 kw 2.6 3.5 4.4 5.3 Model R21C Specifications and Performance
More informationR22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort
R22C/H Packaged Terminal Air Conditioner (PTAC) Straight Cooling Nominal Capacities Btuh 9,000 12,000 15,000 18,000 The Right Fit for Comfort kw 2.6 3.5 4.4 5.3 Model R22C Packaged Terminal Heat Pump (PTHP)
More informationSpecifications and Performance
R15C Packaged Terminal Air Conditioner (PTAC) Straight cooling nominal capacities Btuh 9,000 12,000 15,000 18,000 kw 2.6 3.5 4.4 5.3 The Right Fit for Comfort R15C Specifications and Performance ECR International
More informationCM R-410A High Efficiency Water Source Heat Pump
CM R-410A High Efficiency Water Source Heat Pump MODEL CM - Heat pump nominal capacities 8,000 12,000 15,000 Btuh 2.6 3.5 4.4 kw The Right Fit for Comfort Specifications and Performance ECR International
More informationInstallation, Operation, & Maintenance Manual
R10C/H R20C/H R35C/H R45C/H R80C/H R90C/H Packaged Terminal Air Conditioner (PTAC) Packaged Terminal Heat Pump (PTHP) The Right Fit for Comfort Straight cooling nominal capacities 9,000 12,000 15,000 18,000
More informationModel R11C. Replacement for: Westinghouse "RB" Series Chassis R21C. Replacement for: Climate Master (Friedrich) 701 Series R23C R23H.
R11C R12C R21C R22C/H R23C/H R24C/H Packaged Terminal Air Conditioner (PTAC) Straight cooling nominal capacities The Right Fit for Comfort Btuh 9,000 12,000 15,000 18,000 kw 2.6 3.5 4.4 5.3 R11C R12C R21C
More informationR11C R12C R21C R22C/H R23C/H R24C/H
R11C R12C R21C R22C/H R23C/H R24C/H Packaged Terminal Air Conditioner (PTAC) The Right Fit for Comfort Installation, Operation & Maintenance Manual R11C Replacement for: Westinghouse "RB" Series Chassis
More informationVPRC / VPRH. Specifications and Performance. The Right Fit for Comfort. Vertical Packaged Air Conditioner/Heat Pump
VPRC / VPRH Vertical Packaged Air Conditioner/Heat Pump Straight cool/limited Range Heat pump nominal capacities The Right Fit for Comfort 9,000 12,000 18,000 19,000 2,000 30,000 36,000 Btuh 2.6 3.5 5.3
More informationSeries PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection
Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment
More informationSeries PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection
Series PIC New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction and Renovation; Replaces
More informationWLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)
WLCG/WLHG R-410A High-Efficiency Ductless Split System High-Wall Air Handlers Straight cool / Heat pump nominal capacities WLHG09 WLHG12 WLHG24 Units 9,000 12,000 18,000-23,800 Btuh 2.6 3.5 5.3-7.0 kw
More informationEnviromaster International LLC 5780 Success Dr. Rome, NY Nominal Capacities: 30,000-36,000 Btuh
Nominal Capacities: 30,000-36,000 Btuh Enviromaster International LLC 5780 Success Dr. Rome, NY 13440 www.enviromaster.com An ISO 9001-2000 Certified Company P/N# 240004554, Rev. 1.1 [02/05] VPAC/VPHP
More informationRetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)
Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package
More informationICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS
0 ICE AIR LLC HARTFORD AVENUE, MOUNT VERNON, NY 10553 WEBSITE: http://www.ice-air.com TEL: (914) 668-4700; FAX: (914)668-5643 Draw1 REV. - 117/133 SENS HEAT RATIO, % TOTAL COOL CAP; % 120 110 COOLING CAPACITY
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL RC95 DOWNFLOW DUCTED PTAC REPLACEMENT STRAIGHT COOL ONLY Capacities: 9,000-18,000 Btuh Enviromaster International LLC 5780 Success Dr. Rome, NY 13440 Phone:
More informationNominal Capacities: 9,000 & 12,000Btuh
Nominal Capacities: 9,000 & 12,000Btuh Enviromaster International LLC 5780 Success Dr. Rome, NY 13440 Email: info@retroaire.com An ISO 9001-2000 Certified Company P/N# 240001229, Rev. 1.2 [03/06] RC/RH70
More information1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA
PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL RC85 DOWNFLOW DUCTED PTAC REPLACEMENT for Chromolox Downflow STRAIGHT COOL ONLY Capacities: 9,000-18,000 Btuh Enviromaster International LLC 5780 Success
More informationDivisions of ECR International, Inc. Commercial Zone-Comfort Solutions
TM Divisions of ECR International, Inc. Commercial Zone-Comfort Solutions Contents Page No. E-verter Variable-Speed Commercial Ductless Split Systems................ 2 Air Handlers...................
More informationApplied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat
Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features
More informationJOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:
T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED
More information9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners
PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,
More informationinstallation, operation and maintenance MANUAL
installation, operation and maintenance MANUAL VPAc/VPHP Single Package vertical air conditioner/heat pump For New Construction Only Straight Cool/Heat Pump Nominal Capacities: 9,000-12,000-15,000-17,000-19,000-24,000
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL RC50 PACKAGED TERMINAL AIR CONDITIONER Replacement For: Dunham/Bush Newport Models I, II, III, and IV STRAIGHT COOL ONLY Nominal Capacities: 9,000-12,000-15,000
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL RC15 PACKAGED TERMINAL AIR CONDITIONER REPLACEMENT FOR: American Standard Series 41, American Air Filter Series 25 & Others STRAIGHT COOL Nominal Capacities:
More informationAIR CONDITIONER/HEAT PUMP for New Construction or as a Replacement for IceCap RSK & IslandAire EZ-RK Series
RC/RH22 PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMP for New Construction or as a Replacement for IceCap RSK & IslandAire EZ-RK Series INSTALLATION, OPERATION AND MAINTENANCE MANUAL Cooling Only/Heat Pump
More informationRetroAire VPRC/VPRH. Single Packaged Vertical Unit R-410A Refrigerant
RetroAire VPRC/VPRH R-410A Refrigerant Introduction In the mid-1990 s, RetroAire introduced the Vertical Packaged Unit, then known as a Vertical Packaged Terminal Unit to the market when Motel 6 approached
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationNH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT
ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230
More informationR-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils
R-410A Ductless Split Systems Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps Chilled Water Fan Coils R-410A Ductless Split Systems The EMI Ductless Advantage EMI s Ductless line is specifically
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationN4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL RC55 PACKAGED TERMINAL AIR CONDITIONER STRAIGHT COOL ONLY Nominal Capacities: 9,000-12,000 Btuh Enviromaster International LLC 5780 Success Dr. Rome, NY 13440
More informationDaikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)
Replacement Parts List No. 700018800 Revision C 08/2012 Daikin McQuay EnerSaver Packaged Terminal Air Conditioner/Heat Pump PNES; PNHS 009-015 Design D (4) To find your Daikin Applied parts distributor,
More informationGTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts
GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationUPM I. Unit Protection Module. Installation and Operation Manual (2015/06)
UPM I Unit Protection Module Installation and Operation Manual 6 720 220 321(2015/06) 2 Key to Symbols Contents Key To Symbols...2 Warnings...2 Specifications... 3 Unit Protection Module (UPM)....3 Power
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationIncremental Comfort Conditioners
Style, comfort and energy efficiency...one room at a time. Incremental Comfort Conditioners Model PDNS Top-mounted Hydronic Heat Engineered for flexibility and performance PDNS Incremental Comfort Conditioners
More informationGeneral Description. Operation
ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication
More informationGreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP
MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair
More informationN4H4. Product Specifications
14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors
More informationProduct Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons
Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationSpaceKeeper Console (SKC)
SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationT2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone
T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Multi-Zone Top-Discharge Ductless Split-System Condensing Units for R410 Refrigerant Capacities Multi-Zone Applications T2CG/T2HG, T3CG/T3HG, T4CG/T4HG Units 9,000 12,000
More informationDaikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015
Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationMcQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991
Replacement Parts List No. 055203500 Revision G 05/206 McQuay Climate Control Singer Incremental ES, RS, S 06, 09,, 4 Vintage B Last Manufactured: 99 To find your Daikin Applied parts distributor, call
More informationE Z S E R I E S " W X 16" H
PACKAGED TERMINAL AIR CONDITIONER E Z S E R I E S 4 2 42" W X 16" H Perfect Fit for Replacing Existing 42" X 16" Units and for New Construction Projects M A N U FA C T U R E R O F Q U A L I T Y A I R C
More informationMcQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994
Replacement Parts List No. 05708900 Revision C 06/205 McQuay Incremental Packaged Terminal Air Conditioner MQT 06-4 Vintage B Last Manufactured: 994 To find your Daikin Applied parts distributor, call
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More informationJune PRODUCT DESIGN GUIDE Whisperline Console
June 2018 PRODUCT DESIGN GUIDE Whisperline Console Table of Contents Console Unit Nomenclature 1 AHRI Performance Rating 3 Unit Protection & LED Fault Status 5 Unit Mounted Control 6 Physical Data Table
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL CWC/CWH/CMH CONSOLE WATER SOURCE STRAIGHT COOL/HEAT PUMP SERIES Nominal Circuits: 8,000-10,000, 13,000 & 17,000 Enviromaster International LLC 5780 Success
More informationEMI ENGINEERING SUBMITTAL
(MH4) MULTI-ZONE HEAT PUMP AIR CONDITIONING SYSTEM Rev. 1.4 [3/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT DESIGNATION:
More informationSubmittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationCHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate
More informationCATALOG. SKYPAK Self-Contained Heating/Cooling Units
CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK
More informationS1CV/S1HV Single-Zone
S1CV/S1HV Single-Zone Variable Speed Ductless Split-System Condensing Units and Heat Pumps with R1A Refrigerant Capacities Single-Zone Applications S1CV or S1HV Units 9, 12, 18, 2, Btuh COOL 2.6 3.5 5.3
More informationEMI ENGINEERING SUBMITTAL
(MC2) MULTI-ZONE STRAIGHT COOL AIR CONDITIONING SYSTEMS Rev. 1.4 [4/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT
More informationProduct Data INDUSTRY LEADING FEATURES / BENEFITS
8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design
More informationSpecifications and Performance S2H
DUCTLESS SPLIT SYSTEM Dual-ZONE Heat Pump CONDENSING UNIT P/N# 240006613, Rev. A [06/08] Specifications and Performance Heat Pump Nominal Capacities: 9,000 and 12,000 Btuh DESCRIPTION EMI offers the finest
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationMcQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000
Replacement s List No. 5709900 Revision N 0/205 McQuay Incremental MQE 007, 009, 02, 05, 06 MQR 007, 009, 02, 05 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call -800-377-2787
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 24 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=
More informationMHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH
MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 09 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationCall us today! (800)
150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationPERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems
PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with
More informationPACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency
PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS New Construction Model Model EGN Superior Sound Performance Operating and Transmission Loss (OITC) High Efficiency 42 x 16 Wall Sleeve Semi-Custom Options Modern
More informationWCH5**4. Product Specifications
HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY
More informationSubmittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationSubmittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System
Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote
More informationWJH4 Product Specifications
UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a
More informationProduct Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56
38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND
More information