KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h
|
|
- Mitchell Benson
- 5 years ago
- Views:
Transcription
1 KOG LN Low Noise Chilled Water Cassettes 09, 12 & to 6.10kW 1.58 to 5.10kW 330 to 920 m3/h
2
3 KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes 09 LN to 18 LN offer a comfortable air conditioning with improved acoustic performance. Their design and their small dimensions allow them to fit harmoniously into the standard ceiling tiles of 600 x 600 mm size. These new cassettes have been specially designed for an easy and fast installation, as well as for a great ease of maintenance with a complete access to internal components through the return air grille. The chilled water cassettes are available in 3 sizes (K09OG LN, K12OG LN & K18OG LN) and in 3 versions (2-pipe, 2-pipe/2-wire and 4-pipe). Features and benefits As a result of new motor staging, the noise level has been reduced by 4 to 6 dba at low speed. The casing to be fitted into the false ceiling has a low profile (287 mm thick). Its dimensions as well as the incorporation of electrical box and control valves (optional) inside the unit, make its installation compatible with standard false ceiling tiles (600 x 600 mm size). The casing is made from galvanized steel sheet with thermal and acoustical insulation, eliminating condensations on the casing and providing low sound levels. The grille of RAL 9016 colour combines discharge and return with air filter; discharge manually ajustable on all four sides with possibility of closing one or two faces of discharge, return at the center. The coils are composed of copper tubes and aluminium hydrophilic fins ensuring a better condensate drainage and a better protection against corrosion. The coils of sizes K09OG LN and K12OG LN have 2 rows for 2-pipe and 4-pipe systems. Those of size K18OG LN have 3 rows for 2-pipe and 4-pipe systems. Prepunched holes for connection with fresh air intake and connection with a stub duct to treat air of adjacent room. In this case, it becomes necessary to provide a decompression in the adjacent room to allow air return on the cassette. Easy and quick access, by simply removing the front grille, to the internal components such as the coil, the fan-motor assembly, the condensate pump, the optional regulating valve(s) and the electrical box. All connections : water, electrical, condensate drain and air vent cock are located at the same side, on the exterior of the unit. Sliding electrical box is easily accessible after removing two screws. Electrical box has a junction block provided for quick connection on terminals without screws and a multi-output autotransformer supplied for eventual change of fan speeds (on site). Condensate pump supplied as standard, can be easily reached and removed by only one screw; electrical connection by pin type connector. The condensate pump provides a manometric lift up to 600 mm. The pump is, in addition, equipped with a high security level control system : it is concerning a 3-level detection float ("On", "Off" to avoid permanent operation, and "Alarm"). Control valves (factory-supplied option) mounted inside the casing to limit the works on site and the installation costs. Flexible hoses for connection on units with or without control valves. Filtration Cleanable synthetic type air filter (55 % arrestance, G1 class) accessible after opening the return grille. Fan-motor assembly Centrifugal turbine with direct drive. Motor resiliently mounted and equipped with internal thermal safety device. It can be dismounted by 3 screws and disconnection from electrical supply cable by pin type connector. The chilled water cassettes sizes K09OG LN, K12OG LN and K18OG LN can be supplied with 2 types of motor : The standard AC motor of direct drive type having 6 speeds, 3 of them are factory pre-wired. The motor is suitable for nominal voltage of 230 V / 1~ / 50 Hz and is equipped with a built-in normally closed thermal protection of automatic reset type. The EC motor of high efficiency and low electrical consumption type for a significant energy saving. The motor is suitable for 0-10 V input, ensuring variable speed capability. It is fitted with ECospeed3 interface card (supplied as standard) for a 3-speed optimized running. Electrical connection Fast connection on terminals without screws. Two cable glands are provided on the casing wall allowing to block the supply and control cables. Supply voltage : 230 V / 1~ / 50 Hz + Earth. Available accessories and options IRYS Diffuser the modern design of the IRYS diffuser combines aesthetics and a flat appearance to meet the architectural constraints: Perfect integration into the standard false ceiling, exterior dimensions 595x595. Metallic diffuser which keep colors over time. Epoxy paint RAL 9003 Air diffusion with Coanda effect: Air diffusion in 360 avoiding any dead air zones OR air diffusion in 180. When the air is blown from a point near the ceiling, the air stream is pressed against the ceiling and has an improve air throw. IRYS Diffuser uses this principle of air diffusion "Coanda effect" in order to ensure a homogeneous distribution of the air in the room with a high induction rate and reduced temperatures stratification (less than 1 C). Definition of a comfort zone which eliminates air flow phenomena and temperature stratification (speed of air below 0.15m/s). Air throw: The air throw is the distance between the cassette and the points where the speed of the spread air (approximately 0.2 m/s) is not longer felt by the human body. The IRYS diffuser possesses the blowing reach of air over of 5m in HS. Easy maintenance: Quick access to the filter. Access to internal components. Easy cleaning thanks to a perfectly smooth surface. Electric heater for use with 2-pipe/2-wire system It is composed of heating elements located inside the tubes of heat exchanger and is thermally protected against abnormal rises in temperature by two thermostats : automatic reset thermostat and manual reset one. Supply voltage : 230 V / 1 ph / 50 Hz + earth. Control valves Motorized valves, 2 ways and 3 ways with by-pass, factory-fitted option and incorporated inside the unit for 2-pipe and 4-pipe systems. Controls TRM-VP (kit), TRM-FA (kit), TAE 20 (kit), TAE 20 + SEH (kit), Aqu@Simp, Aqu@Net and IR remote control. 1
4 2 KOG LN 9 / KOG LN 12 / KOG LN 18 Advantages of Chilled Water Cassettes LN with EC motor Energy class with standard motor More efficient FCEER FCCOP K09OG LN K12OG LN K18OG LN K09OG LN K12OG LN K18OG LN 2-pipe 4-pipe 2-pipe 4-pipe Less efficient Energy class with EC motor More efficient FCEER FCCOP 2-pipe 4-pipe 2-pipe 4-pipe Less efficient 3-speed control interface for EC motor Aqu@Net Interface card 3 speeds EC motor 0 to 10 V ECoSpeed3
5 KOG LN 9 / KOG LN 12 / KOG LN 18 3 designation K12OGLN. 2P. EC. SYS. 1800W. N. NIU. 3W. I180 + FH REP. Description 1 Size K09OGLN : KOG LN size 9 K12OGLN : KOG LN size 12 K18OGLN : KOG LN size 18 2 Coil 2P : 2 pipes 4P : 4 pipes 3 Fan type Blank : AC fan EC : EC fan 4 Brand SYS : SYSTEMAIR 5 Electric heater Blank : Without heater 1500W : Capacity 1500W 1800W : Capacity 1800W 2400W : Capacity 2400W 6 Regulation Blank : Terminal block D : Aquanet FCC controller 2 pipes/ without valve/cooling only E : Aquanet FCC controller 2 pipes/valve/ cooling only F : Aquanet FCC controller 2 pipes/ without valve/heating only G : Aquanet FCC controller 2 pipes/valve/ heating only H : Aquanet FCC controller 2 pipes/valve/ heating only/change over J : Aquanet 2 pipes/without valve/ heating only/change over L M N P Q : Aquanet FCC controller 4 pipes/valve : Aquanet FCC controller 2 pipes/ cooling only/electric heater : Aquanet FCC controller 2 pipes/ without valve/reversible cycle/ Change over : Aquanet FCC controller 2 pipes/valve/ reversible cycles/change over : Aquanet FCC controller 2 pipes/valve/ reversible cycle/change over/ electric heater 7 Option Aquanet NIU : µbms compatible communication board NIU for Aquanet eniu : Modbus communication board eniu for Aquanet 8 Valve Blank : Without valve 2W : 2 way valve 3W : 3 way valve 9 Facade Blanck : Standard plastic I360 : IRYS COANDA 360 I180 : IRYS COANDA Option FH IR : Fuse holder : IR for Aquanet FCC controller NOECO : Without Ecospeed3 C/O : Change over
6 4 KOG LN 9 / KOG LN 12 / KOG LN 18 Technical Data KOG LN with AC motor Capacites - 2 pipe Cooling (1) K09OG LN K12OG LN K18OG LN S1/S2/S3 S1/S2/S3 S1/S2/S3 Total cooling capacity W 1580/1870/ /2570/ /3650/4530 Sensible capacity W 1230/1470/ /2020/ /2900/3780 Water flow l/h 280/330/ /450/ /640/790 Water pressure drop kpa 6/9/12 8/11/18 8/11/16 Heating (2) Heating capacity W 2100/2500/ /3200/ /4600/5700 Capacites - 4 pipe Cooling (1) Total cooling capacity W 1580/1870/ /2570/ /3650/4530 Sensible capacity W 1230/1470/ /2020/ /2900/3780 Water flow l/h 280/330/ /450/ /640/790 Water pressure drop kpa 6/9/12 8/11/18 8/11/16 Heating capacity W 1700/1900/ /2500/ /3950/4470 Heating (3) Water flow l/h 160/180/ /220/ /340/380 Sound levels - 2 pipe Water pressure drop kpa 3/4/5 7/9/13 19/27/31 Sound power level db(a) 34/40/52 34/40/50 41/49/57 Sound pressure level(*) db(a) 26/32/42 26/32/42 33/41/49 NR db(a) 20/27/37 20/27/37 28/35/43 Sound levels - 4 pipe Sound power level db(a) 34/40/50 34/40/50 43/49/57 Sound pressure level(*) db(a) 34/50/34 26/32/42 33/41/49 NR db(a) 26/42/26 20/27/37 28/35/43 Fans Number Air flow - 2 pipe m³/h 330/450/ /450/ /580/830 Air flow - 4 pipe m³/h 330/450/ /450/ /580/830 Electrical data Power supply V/Ph/Hz 230V/1~/50Hz Absorbed power - 2 pipe W 20/30/50 20/30/50 30/46/71 Absorbed power - 4 pipe W 20/30/50 20/30/50 30/46/71 Electrical heater W Water connections type Gas male threaded 2 pipe or 4 pipe "Cooling" pouce 1/2" 1/2" 3/4" 4 pipe "Heating" pouce 1/2" 1/2" 1/2" Dimensions plastic facade Casing mm 571 x 571 x x 571 x x 571 x 287 diffuser mm 625 x 625 x x 625 x x 625 x 40 Casing mm 571 x 571 x x 571 x x 571 x 293 IRYS facade diffuser mm 595 x 595 x x 595 x x 595 x 34 Weight 2 pipe kg pipe kg (1) Nominal conditions : Air : 27 C/19 C wet bulb (nominal air flow in high speed). Chilled water : 7 C/12 C. (2) Nominal conditions : - In 2-pipe configuration : air : 20 C (nominal air flow in high speed); hot water : entering temperature 50 C (nominal water flow obtained in cooling mode). - In 4-pipe configuration : air : 20 C (nominal air flow in high speed); hot water : 70 C / 60 C. (3) Water pressure drops given for the corresponding nominal water flow on cassettes without control valves. (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter.
7 KOG LN 9 / KOG LN 12 / KOG LN 18 5 Technical Data KOG LN with EC motor Capacites - 2 pipe Cooling (1) K09OG LN K12OG LN K18OG LN S1/S2/S3 S1/S2/S3 S1/S2/S3 Total cooling capacity W 1590/1890/ /2220/ /3680/4560 Sensible capacity W 1240/1490/ /1910/ /2930/3810 Water flow l/h 280/330/ /384/ /640/790 Water pressure drop kpa 6/9/12 7/10/16 8/11/16 Heating (2) Heating capacity W 2100/2500/ /2910/ /4600/5700 Capacites - 4 pipe Cooling (1) Total cooling capacity W 1590/1890/ /2590/ /3680/4560 Sensible capacity W 1240/1490/ /2040/ /2930/3810 Water flow l/h 280/330/ /450/ /640/790 Water pressure drop kpa 6/9/12 8/11/18 9/11/16 Heating capacity W 1700/1900/ /2500/ /3950/4470 Heating (3) Water flow l/h 160/180/ /220/ /340/380 Sound levels - 2 pipe Water pressure drop kpa 3/4/5 7/9/13 17/24/28 Sound power level db(a) 34/40/50 37/40/ /49/57 Sound pressure level(*) db(a) 26/32/42 26/32/42 33/41/49 NR db(a) 20/27/37 20/27/37 28/35/43 Sound levels - 4 pipe Sound power level db(a) 34/40/50 34/40/ /49/57 Sound pressure level(*) db(a) 26/32/42 26/32/42 33/41/49 NR db(a) 20/27/37 20/27/37 28/35/43 Fans Number Air flow - 2 pipe m³/h 330/450/ /450/ /580/830 Air flow - 4 pipe m³/h 330/450/ /450/ /580/830 Electrical data Power supply V/Ph/Hz 230V/1~/50Hz Absorbed power - 2 pipe W 8/11/26 8/11/26 9/23/41 Absorbed power - 4 pipe W 8/11/26 8/11/26 9/23/41 Electrical heater W Water connections type mâle fileté gaz 2 pipe or 4 pipe "Cooling" pouce 1/2" 1/2" 3/4" 4 pipe "Heating" pouce 1/2" 1/2" 1/2" Dimensions plastic facade Casing mm 571 x 571 x x 571 x x 571 x 287 diffuser mm 625 x 625 x x 625 x x 625 x 40 Casing mm 571 x 571 x x 571 x x 571 x 293 IRYS facade diffuser mm 595 x 595 x x 595 x x 595 x 34 Weight 2 pipe kg pipe kg (1) Nominal conditions : Air : 27 C/19 C wet bulb (nominal air flow in high speed). Chilled water : 7 C/12 C. (2) Nominal conditions : - In 2-pipe configuration : air : 20 C (nominal air flow in high speed); hot water : entering temperature 50 C (nominal water flow obtained in cooling mode). - In 4-pipe configuration : air : 20 C (nominal air flow in high speed); hot water : 70 C / 60 C. (3) Water pressure drops given for the corresponding nominal water flow on cassettes without control valves. (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter.
8 6 KOG LN 9 / KOG LN 12 / KOG LN 18 Electrical Data KOG LN with AC motor K09OG LN.2P K12OG LN.2P K18OG LN.2P With BE Without BE With BE Without BE With BE Without BE Nominal current A Fuse rating gg A 10 1 ** 10 1 ** 16 1 ** Fuse rating ASE/VDE** A Power supply 230V/1~/50Hz Cable section* mm 2 3G1.5 3G1 3G2.5 3G1 3G2.5 3G1 Electric heater capacity W 1500 / 1800 / 2400 / K09OG LN.4P K12OG LN.4P K18OG LN.4P Nominal current A Fuse rating gg A Fuse rating ASE/VDE** A Power supply 230V/1~/50Hz Cable section* mm 2 3G1 3G1 3G1 BE : Electric heater. * Minimum section to be adapted according to local regulations and norms. ** am or circuit breaker curve C. KOG LN with EC motor K09OG LN.2P K12OG LN.2P K18OG LN.2P With BE Without BE With BE Without BE With BE Without BE Nominal current A Fuse rating gg A 10 1 ** 10 1 ** 16 1 ** Fuse rating ASE/VDE** A Power supply 230V/1~/50Hz Cable section* mm 2 3G1.5 3G1 3G2.5 3G1 3G2.5 3G1 Electric heater capacity W 1500 / 1800 / 2400 / K09OG LN.4P K12OG LN.4P K18OG LN.4P Nominal current A Fuse rating gg A Fuse rating ASE/VDE** A Power supply 230V/1~/50Hz Cable section* mm 2 3G1 3G1 3G1 BE : Electric heater. * Minimum section to be adapted according to local regulations and norms. ** am or circuit breaker curve C. Standard fan motor electrical data Fan speed K09OG LN K12OG LN K18OG LN Absorbed current (A) Absorbed power Absorbed current (A) Absorbed power Absorbed current (A) S S S S4 / / / / / / EC fan motor electrical data Fan speed K09OG LN K12OG LN K18OG LN Absorbed Absorbed Set Absorbed Absorbed Set Absorbed current (A) power Voltage (V) current (A) power Voltage (V) current (A) Absorbed power Absorbed power Set Voltage (V) S S S S4 / / / / / /
9 KOG LN 9 / KOG LN 12 / KOG LN 18 7 Electrical Data Electric heater The electric heater of the cassettes is composed of heating resistances placed inside the tubes of the heat exchanger. These resistances are heat protected against any abnormal temperature rise by two thermostats equipped with a "positive safety" device (mechanical or thermic destruction of the capillary switches off the heating permanently) : K09OG LN K12OG LN K18OG LN Capacity W OO OO a thermostat with automatic reset, a thermostat with manual reset. Acoustical Data KOG with AC motor Data based on units 2 tubes Value for plastic facade with/without fresh air intake and IRYS facade without fresh air intake (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter. KOG with EC motor Acoustical power per octave band (db(a)) Speeds K09OG LN K12OG LN K18OG LN Data based on units 2 tubes Value for plastic facade with/without fresh air intake and IRYS facade without fresh air intake Lw Global db(a) (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter. Lp* db(a) S S S S S S S S S Acoustical power per octave band (db(a)) Speeds K09OG LN K12OG LN K18OG LN Lw Global db(a) Lp* db(a) S S S S S S S S S NR* NR*
10 8 KOG LN 9 / KOG LN 12 / KOG LN 18 Thermal Performance - 2 pipe KOG LN with AC motor Speeds Humid air flow (m 3 /h) Water flow (l/h) WPD (kpa) Cooling Pt Ps Heating Pc K09OG LN.2P K12OG LN.2P K18OG LN.2P S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) KOG LN with EC motor Speeds Humid air flow (m 3 /h) Water flow (l/h) WPD (kpa) Cooling Pt Ps Heating Pc K09OG LN.2P K12OG LN.2P K18OG LN.2P S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S Performances based on : ² ² Summer : air 27 C/19 C (wet bulb) and chilled water 7/12 C. ² ² Winter : air 20 C, entering water température 50 C, water flow identical to cooling mode.. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pc : Heating capacity. WPD : Water pressure drop Standard wiring of the 3 speeds. Other speed combinations available upon request.
11 KOG LN 9 / KOG LN 12 / KOG LN 18 9 Thermal Performance - 4 pipe KOG LN with AC motor K09OG LN.4P K12OG LN.4P K18OG LN.4P Speeds Humid air flow (m 3 /h) Cooling Pt Ps Water flow (l/h) WPD (kpa) Heating Pc Water flow (l/h) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) WPD (kpa) KOG LN with EC motor K09OG LN.4P K12OG LN.4P K18OG LN.4P Speeds Humid air flow (m 3 /h) Cooling Pt Ps Water flow (l/h) WPD (kpa) Heating Pc Water flow (l/h) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S1 (Eurovent) S2 (Eurovent) S3 (Eurovent) S WPD (kpa) Performances based on : ² ² Summer : air 27 C/19 C (wet bulb) and chilled water 7/12 C. ² ² Winter : air 20 C, entering water température 50 C, water flow identical to cooling mode.. Pt : Total cooling capacity. Ps : Sensible cooling capacity. Pc : Heating capacity. WPD : Water pressure drop Standard wiring of the 3 speeds. Other speed combinations available upon request.
12 10 KOG LN 9 / KOG LN 12 / KOG LN 18 Air throw I180 S1 S2 S3 K09OG LN AC Airflow m 3 /h Throw m K12OG LN AC Airflow m 3 /h Throw m K18OG LN AC Airflow m 3 /h Throw m I360 S1 S2 S3 K09OG LN AC Airflow m 3 /h Throw m K12OG LN AC Airflow m 3 /h Throw m K18OG LN AC Airflow m 3 /h Throw m K12OG LN - I V1 4 V V métres K12OG LN - I V1 4 5 V V métres K12OG LN - I V métres 40cm K12OG LN - I m/s<V 0.5m/s<V<1.0m/s 0.2m/s<V<0.5m/s V métres 40cm m/s<V 1.0m/s<V<1.5m/s 0.5m/s<V<1.0m/s 0.2m/s<V<0.5m/s
13 KOG LN 9 / KOG LN 12 / KOG LN Water Pressure Drops K09OG LN 50 C 40 D 30 A kpa B l/h Curve A : Curve B : Curve C : Curve D : Pressure drop of heating circuit with control valve (4-pipe system). Pressure drop of heating circuit without control valve (4-pipe system). Pressure drop of cooling circuit with control valve (2 and 4-pipe systems). Pressure drop of cooling circuit without control valve (2 and 4-pipe systems). K : Glycol coefficient Twm ( C) % Glycol Twm : Average temperature of the mixture. Pwo : Pure water pressure drop. Pw : Brine water pressure drop. Pw : K x Pwo. % Glycol Tse ( C) yes -20 yes yes -15 yes yes -10 yes yes yes -5 yes yes yes yes 0 yes yes yes yes yes 5 yes yes yes yes yes Tse : Outdoor dry bulb temperature.
14 12 KOG LN 9 / KOG LN 12 / KOG LN 18 Water Pressure Drop K12OG LN 50 C 40 A 30 B kpa D l/h Curve A : Pressure drop of heating circuit with control valve (4-pipe system). Curve B : Pressure drop of heating circuit without control valve (4-pipe system). Curve C : Pressure drop of cooling circuit with control valve (2 and 4-pipe systems). Curve D : Pressure drop of cooling circuit without control valve (2 and 4-pipe systems). K18OG LN A B C kpa D l/h
15 KOG LN 9 / KOG LN 12 / KOG LN Operating Limits Use of chilled water Lower limits plastic facade IRYS facade Thi Indoor temperature C Tsi Water temperature C Twe 5 6 Higher limits plastic facade IRYS facade Thi Indoor temperature C Tsi Water temperature C Twe Thi : Tsi : Twe : Indoor wet bulb temperature. Indoor dry bulb temperature. Entering water temperature. Use of hot water Thi 22 Maximum indoor temperature C Tsi 32 Maximum entering water temperature C Twe 70 (1) (2) Thi : Tsi : Twe : Indoor wet bulb temperature. Indoor dry bulb temperature. Entering water temperature for 2 or 4-pipe systems. Water connections Fresh air intake Fresh air flow should not exceed 12 % of nominal air flow (see table below). An antifreeze thermostat, switching off the external fan at +5 C, must be used on fresh air intake during winter period. A filter, fan and insulated air duct are to be provided on site. (1) : For reversible 2-pipe system with extra electric heater energized, maximum Twe is 35 C. (2) : For applications with water temperature higher than 70 C, consult factory. 9 LN 12 LN 18 LN Contents l 1,3 1,3 2 Maximum operating pressure bar Test pressure bar Couplings (2-pipe system) Ø 1/2" gas male 1/2" gas male 3/4" gas male mm male male male Couplings (4-pipe system) KOG LN with AC motor Ø 1/2" gas male 1/2" gas male mm male male K09OG LN K12OG LN K18OG LN 2P 4P 2P 4P 2P 4P Nominal air flow in high speed m 3 /h Maximum fresh air flow m 3 /h KOG LN with EC motor K09OG LN K12OG LN K18OG LN 2P 4P 2P 4P 2P 4P Nominal air flow in high speed m 3 /h Maximum fresh air flow m 3 /h The new air must be preprocessed to prevent any risk of condensation on the product. 1/2" gas male (heating) 3/4" gas male (cooling) male (heating) male (cooling)
16 14 KOG LN 9 / KOG LN 12 / KOG LN 18 Dimensional Data (mm) KOG LN 2 pipe (IRYS) B A Ø Ø (IRYS) (IRYS) (IRYS) C legend 1 False ceiling 7 Condensate drain (Ø15) 2 T-shaped rod (false ceiling) 8 3 Coil 9 4 Fan 10 5 Suction grille 11 6 Electrical connection 12 Air vent Water leaving gas male coupling (refer to table "water connections") Water entering gas male coupling (refer to table "water connections") Port for fresh air succion (ready to punch out) Opening for ducted air distribution into the adjacent room (ready to punch out) (IRYS) K09OG LN.2P K12OG LN.2P K18OG LN.2P A B C KOG LN 2 pipe (IRYS) B1 A 12 B2 E 11 Ø Ø (IRYS) (IRYS) (IRYS) C D legend 1 False ceiling 7 Condensate drain (Ø15) 2 T-shaped rod (false ceiling) 8 3 Coil 9 4 Fan 10 5 Suction grille 11 Water leaving gas male coupling (refer to table "water connections") Water entering gas male coupling (refer to table "water connections") Port for fresh air succion (ready to punch out) Opening for ducted air distribution into the adjacent room (ready to punch out) 6 Electrical connection 12 Chilled water air vent (IRYS) K09OG LN.4P K12OG LN.4P K18OG LN.4P A B B C D E
17 Notes KOG LN 9 / KOG LN 12 / KOG LN 18 15
18 16 KOG LN 9 / KOG LN 12 / KOG LN 18 Notes
19
20 Systemair AC SAS route de Verneuil, Tillières-sur- Avre Tél Fax Systemair EDM KOG1-S-4GB/ Supersedes EDM KOG1-S-3GB/02.15 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. may 2016
KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45
KOG LN Low Noise Chilled Water Cassettes Models 30 & 45 Design Features Introduction Chilled Water units of the "Cassette" type offer comfortable air conditioning at a low cost of installation. They fit
More informationRefrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as
More informationX X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.
Refrigerant R407C X 1200 - X 1900 Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) 12.3 to 18.0kW 1500 to 3800 m 3 /h X 1200 / X 1900 1 Product Codes Models AR
More informationSYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.
Air Conditionné Chillers & Heat Centrales Pumps de Water traitement terminals d air Ventilateurs Rooftops Close Sécurité control incendie Water Grilles source et heat Diffusion pumps Composants Direct
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationAQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual
u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water
More informationCATALOG WATER SOURCE HEAT PUMPS
CATALOG Fan coil UNITS WATER SOURCE HEAT PUMPS DIRECT EXPANSION 2014 An InternatIonaL sales network NORD-PAS- DE-CALAIS PICARDIE HAUTE- NORMANDIE BASSE- NORMANDIE Tillières-sur-Avre ILE-DE-FRANCE Guyancourt
More informationPackaged air conditioners vertical units
X 4650 - X 6450 Packaged air conditioners vertical units q Air cooled models (AC) q Water cooled models (WC) q Refrigerant R407C q Capacities from 38.9 to 55.0 kw X 4650 - X 6450 CONA 74 Version: July,
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationDUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX
Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system
More informationCassette units Model Comfort Circle. - heating - cooling - ventilation
Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationconsumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK
NEW energy consumption ECM motors ECM Cassette Fan Coil Units www.eurovent-certification.com www.certiflash.com CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page 5 Emissions
More informationSkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board
SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM
Air Conditioning Fan Coil Units ICIM ISO 900 - Cert. n 0545/2 Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Sabiana is the fan coil that continues the Sabiana
More informationSPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC
APPLICATION GUIDE CHILLED WATER CASSETTE CWC - P/4P English/03-005 INDEX Index AGU CWC-P/4P General Description Specifications Performances tables Sound levels Options Dimensions Unit installation Electrical
More informationFCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option
FCX FAN COIL SILENT & EFFICIENT Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option THE AERMEC FAN COILS Fan coils and Aermec: a combination where the
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationCWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT
TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More informationSystem architecture. Air treatment Index
System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationtechnical data Fan coil unit FWB small duct unit
technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------
More informationQTS SELECTION TECHNICAL BOOKLET
EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationUniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016
UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationFans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL Wall mounted fan coil units SYSWALL Wall mounted fan coil units With a tangential
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction
More informationGalletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better
www.galletti.it Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing 2012 Create value to design better A guide to choosing The group It s 1961 and Galletti with its Jolly copper
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationSkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor
SkyStar SK Cassette Fan Coil Unit with Asynchronous Motor Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the SkyStar chilled water Cassette is the result
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationOMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES
OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES Floor & ceiling installation On/off & inverter versions, applicable with VMF management system OMNIA RADIANT AND
More information> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center
Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-00 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw
More informationCOMFORT HYDRONIC TERMINALS
COMFORT HYDRONIC TERMINALS i i-chd NEW GENERATION CASSETTE WITH EC HIGH EFFICIENCY MOTOR. CENTRIFUGAL FAN WITH CONTINUOUS AIR FLOW REGULATION AND SPEED MODULATION. ENERGY CONSUMPTION REDUCED BY MORE THAN
More informationWATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP
EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationEXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction
Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision
More information42AM. Air heaters PRODUCT SELECTION DATA
PRODUCT SELECTION DATA The best solution for heating large spaces Ensures buildings warm up ultra-fast Excellent diffusion via patented JET+ double deflection technology Air heaters 4AM Translation of
More information50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control
PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original
More informationUCS UCS/M UCS/H UCS900
EN UCS UCS/M UCS/H UCS900 EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous modulation
More informationAdvance Split
Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.
More information4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB
4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationNEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT
NEW energy consumption ECM motors Air Conditioning ECM Cassette Fan Coil Units ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationCOOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw
COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding
More informationКомпрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.
1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing
More informationQZHW Fan Coil Unit. Key features. Specifications
Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different
More informationThe technical and dimensional data reported in this manual may be modified in view of any product improvement.
fan coils technical manual GB E U R O V E T CERTIFIED PERFORMACE IDEX MAI FEATURES... VERSIOS AD MAI COMPOETS... 3-3 AVAILABLE ACCESSORIES... 5 RATED TECHICAL FEATURES... 6-7. Fan coils with heat exchanger
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationEASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB
R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL
More informationPrecision air handling cabinets Ciatronic MICRO/EXPAIR
/ Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to
More informationNEW GREEN TECHNOLOGY
NEW GREEN TECHNOLOGY - suitable for all heating systems Magnetic Boiler installed in all fan coils - no need for external devices! A c t i v e G r e e n S w e d e n A B ACTI VE Operation limits This technology
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationEEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT
EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT Fan coil units 1 Hydronic Systems Fan coil units 1 F
More informationCentrifugal air heaters hot water or electrical supply
The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationApplication guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E
Application guide ARMONIA ARMONIA EC 1,3-11 kw Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E TABLE OF CONTENTS APPLICATION GUIDE Ref : ARMONIA-AGU-1010-E ARMONIA Introduction
More informationMAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation
Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationCOMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT
COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT climaveneta.com COMFORT APPLICATION HYDRONIC TERMINALS between elegance, comfort and energy savings Conceived to
More informationAir treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings
0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric
More informationPackaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB
Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...
More informationQFDK "ägir II" chilled water cassette
Key features Chilled water cassette Cooling ( pipes) and heating (4 pipes or electrical heating) ECM version for low energy consumption Beautiful design, six different sizes, high control flexibility,
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationKELVIN Clim F497. Kelvin air conditioning
KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,
More informationFAN COIL UNITS LASER / LOW BODY / CONCEALED
SAPHIR TECHNICAL LITERATURE FAN COIL UNITS LASER / LOW BODY / CONCEALED Energy Saving Technology EST (Energy Saving Technology) is applied to the Johnson Controls fan coil units and cassette units. It
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationTechnical Manual. New Water Cassette. Series BREZZA DOUBLE
Technical Manual New Water Cassette Series BREZZA DOUBLE AERTESI srl Cassetta BREZZA DOUBLE Tecnical manual AER.MT.I.BREDOPPIA.000.02.15 Pag.2 INDEX 1-INTRODUCTION 4 2- WORKING CONDITION LIMITS..4 3- COANDA
More informationMODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit
MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationNeosys Product catalogue
00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled
More informationQZB "Standard" comfort fan coil
Key features Vertical or horizontal installation Concealed installation or with decorative cabinet Cooling ( pipes) and heating ( pipes or electrical heating) ECM version for low energy consumption The
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More informationNEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning
: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision
More informationTECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:
Biddle Air Systems Limited St. Mary s Road, Nuneaton,Warwickshire CV AU. Tel: + 0 78 Fax: + 0 77 Email: sales@biddle-air.co.uk http://www.biddle-air.co.uk F.H. Biddle B.V. P. O. Box, NL-988 ZG Kootstertille,The
More informationART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW
Fan coil ART-U NEW PRODUCT Design fan coil unit with a minimum depth of 10 cm only and BLDC motor ART-U 1-4 kw Available from SEPTEMBER 2018 Design-driven innovation BLDC motor Tangential fan Supervision
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationPYXIS U PYXIS U. rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More information