TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK
|
|
- Rudolph Griffith
- 5 years ago
- Views:
Transcription
1 GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added to the supply air stream (indirect cooling). These coolers comprise two supply air fans, four exhaust air fans, sixteen indirect heat exchanger core packs, water reservoir, pump, and chlorinator system. CABINET AND BASE FRAME The cabinet is constructed from 304 stainless steel incorporating the motor / fan assemblies, non-corrodible heat exchange cores and other ancillary equipment all supported by a heavy gauge galvanized base frame for structural stability. Fork lift tine channels are provided within the base frame to facilitate transport and lifting. Lifting chains / straps could also be used through these channels with appropriate lifting equipment onto elevated structures (e.g. roof of a building). Components are effectively treated to ensure corrosion resistance and mechanical fasteners are zinc coated steel and stainless steel as appropriate. Connection interface surfaces are provided for the outlet ductwork to the customer ductwork to enable fitment using established industry practices. FANS The fans are a multi blade, centrifugal type with backward curved blades and single inlet. They have black coated rotors and aluminium impellers and are individually statically and dynamically balanced. The fans are directly mounted to the electric motors. The electric motors are high efficiency, electronically commutated and speed controlled to optimise efficiency particularly at low speeds. HEAT EXCHANGE CORES The heat exchange cores are designed to facilitate heat exchange between the wet and dry air passages such that high efficiency heat transfer takes place without the addition of any moisture. They are designed to provide long life and long term high efficiency. ELECTRICAL CABINET AND CONTROLS Control equipment including motor control hardware, PLC control system, touch screen and other electrical equipment is pre-wired and factory mounted within a robust IP66 enclosure suitable for outdoor conditions. WATER DISTRIBUTION SYSTEM The water supply connection is a 316 stainless steel ½ BSPT fitting that connects to the internally mounted electrically operated water solenoid. Heat exchange cores saturation is achieved through internally mounted pump delivering water to a specially designed non-clog water distribution system providing continuous uniform flow. The wet components of each pump are manufactured from stainless steel and the pumps are driven by a 3 phase industrial, fully enclosed fan cooled electric motor with thermal overload protection. Easily cleanable in line strainers are provided for both the incoming water supply and the water distribution system. WATER MANAGEMENT SYSTEM The cooler includes an electronic water management system that controls the maximum salinity level of the reservoir water through continuous monitoring, draining and automatic replenishment as determined by the control system. AIR FILTER Intake air is filtered through easily accessible, washable and replaceable pleated filters. BMS INTERFACE A BACnet module (optional) provides full BACnet interface for control and monitoring of the cooler. Remote control of the cooler is possible via dedicated BMS terminals provided within the electrical cabinet. RESERVOIR The reservoir is constructed from polymer to ensure durability and corrosion resistance. The reservoir is designed to house the water pump and accommodate the level control, chlorinator system, and salinity monitoring water management system. The design of the reservoir and watering system ensures that no water remains after draining. ILL2388-A 1 of 8 ES E120-B AU1804
2 ELECTRICAL SYSTEM OVERVIEW ILL2345-A WATER CONNECTION 1/2 BSPT Male thread connection on cooler. Water Supply Temperature: Max. 40 C ILL2255-A In areas subject to freezing, the water line needs a drain down facility. If the water pressure exceeds the maximum specification then a pressure reducing valve is required and must be supplied and fitted by the installer. ILL2356-A DRAIN CONNECTION A built-in Drain Valve is controlled by the Water Management System. Drain water and tank overflow water must be carried away to a suitable discharge point in accordance with local regulations. The drain outlet provided will accept an NPS 2 inch (DN50) PVC pipe. Direct water into an open drain. 2 of 8 ES E120-B AU1804
3 BACnet INTERFACE OPTIONS FOR CW-80 SERIES BACnet is currently offered as an option on all CW-80 Series coolers. The popular protocols BACnet/IP and BACnet MS/TP can be provided as well as BACnet Ethernet. Communication items (referred to as objects ) form the key to the BACnet system. Seeley International have developed a full set of 108 objects for the CW-80 Series range of coolers. This set of objects (referred to as an objects list ) is detailed in the cooler Installation and Operation Manual BACnet Object List CW-80 Series and is available to assist customers in designing their building management control systems. This objects list can be divided into two groups - 17 objects that can be both read and modified by the customer and the balance of 91 objects that can be read only. The first group of 17 modifiable objects are associated with controlling and operating the CW-80 Series cooler as summarized in the following table: - Item Objects Details basic control 6 control of BACnet active, run, cool, direct cool (supercool only), fan speed, water tank drain master error reset 2 ability to reset errors clock 8 provision for adjusting clock - daylight saving BACnet integrity 1 used to confirm BACnet signal integrity (selectable feature) The second group of 91 read only objects are associated with the status of the CW-80 Series cooler as summarized in the following table: - Item Objects Details basic 19 software number, version and date, control mode, current operating status, watering sequence control, commissioning mode BMS 7 status of standard hard wired BMS signals air temperatures and humdity 8 air temperatures in both deg C and deg F for ambient, intermediate (supercool only) and supply air humidity in RH% for ambient and supply air pressures 4 differential pressure across the supply and exhaust parts of the core in both Pa and inches of water fans 10 supply and exhaust fan speeds, enable signals, normal signals tank 9 status of tank water level sensors, inlet solenoid, drain valve, chlorinator enable and adequate voltage output, average tank refill time, drain delay elapsed period watering system 2 operating status of indirect pump and direct (supercool only) pump Item Objects Details salinity 2 status of high salinity signal and timed drain in progress hours 6 accumulated running time in hours for overall cooler, supply fans, exhaust fans, indirect pump, direct pump (supercool only), chlorinator errors 24 water supply poor or inadequate at various stages of the tank fill or refill, indirect pump overload, direct pump (supercool only) overload, supply fan errors, exhaust fan errors, chlorinator warning and critical errors, high inlet air filter differential pressure error, low exhaust pressure error, unit operating in forced vent mode or has shut down due to combination of errors With the BACnet option installed, the standard BMS interface is still available should this be required. In this scenario the customer would control the cooler using the standard BMS interface but at the same time utilise the BACnet system only to monitor the detailed status of the cooler. A specific BACnet object is provided so that the customer can freely select either this style of control or normal full BACnet control. BACnet field wiring is simple as only a single pair of shielded wires is required to be connected to two terminals. Further, in multiple cooler installations this wiring can be looped from one cooler to the next up to a maximum of 127 coolers whilst still maintaining individual control and status monitoring. 3 of 8 ES E120-B AU1804
4 TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK FRONT TOP ILL2387-B SUPPLY OUTLET ILL2387-B ILL2391-A ILL2391-A PLUMBING DOOR SWING ILL2530-A ILL2529-A SIDE REAR (CONTROL PANEL) Option: Attenuator Ready Exhaust Ducts replacing Weatherseals ILL2309-A ILL2390-B ILL2389-B ILL2390-B 4 of 8 ES E120-B AU1804
5 Specification Services Environment Performance Supply Motors/Fans Exhaust Motors/Fans * Cooling capacity measured to Australian Standard AS , ambient of 38 C dry bulb & 21 C wet bulb, with room exit temperature of 27.4 C. Sound Power Level (without High Capacity option) Electrical Supply Water Supply Max. Operating Temp High Speed Nominal Cooling Capacity* kw Standard High Capacity option Standard High Capacity option Diecast aluminium housing. Inverter drive with 0-10V control and overload protection. Diecast aluminium housing. Inverter drive with 0-10 V control and overload protection CW-80T 3 phase N+E, V 50Hz 22A 3 phase N+E, V 50Hz 27A 1/2 male BSPT connection. Recommended pressure range 200 to 500 Kpa. Maximum pressure (static) 800 Kpa Minimum flow rate through 10.0mm test orifice: 45 L/min Radiated Power in horizontal direction with supply duct connected (db re 1pw) Octave Band Centre Frequency (HZ) Total Sound Power Level (dba re 1pw) k 2k 4k 8k CW-80, CW-80S Or Minimum pressure measured at connection point whilst simultaneously delivering 45 L/min: 85 Kpa 55 deg C ambient (measured in shade) Supply - 6,400 l/sec (23,040 m 3 100Pa Exhaust - 5,240 l/sec (18,860 m 3 /hr) Supply - 6,400 l/sec (23,040 m 3 430Pa Exhaust - 5,240 l/sec (18,860 m 3 /hr) 19.8 deg C supply temp, standalone cooling 143.4kW pre-cooling outside air V 50 / 60Hz 2 fans / motors, 560mm dia V 50 / 60Hz 4 fans / motors, 355mm dia Supply Air Outlet Top discharge, vertical duct. 1,500 x 1,000mm IP55 304/316 Stainless Steel wet end Pump - (Indirect) construction 0.75kW 3 phase 50 / 60 Hz IP55 304/316 Stainless Steel wet end Pump - (Direct) construction nil Chlorinator Controller and Cells 240V 50Hz Salinity Salinity Water Manager Seeley International P/Ltd Management Water Probe Seeley International P/Ltd low voltage, Drain Valve vertical, electric servo motor drive 24VAC, P/No Supplied horizontal outlet accepts 60.35mm Drain Connection OD (DN50) PVC pressure water pipe NPS 2 inch PVC Seeley International P/Ltd Water Reservoir moulded polymer 180 litre capacity Seeley International P/Ltd Heat Exchange Core synthetic plate type, super efficient 16 cores Shipping Dimensions 3,001 L * 2,310 W * 2,547mm H Weight 1,954 kg Operating Weight Weight including reservoir water, system water, supply and exhaust stator ducts. 2,655 kg Air Filtration MERV 7 (G4) washable filters (standard) 622 x 622 x 45mm deep (nominal 25 x 25 x 2 deep) Standards Compliance AS / IEC / EN CE Marking 5 of 8 ES E120-B AU1804
6 CW-80T STANDARD AUSTRALIA, EUROPE, SOUTH AFRICA & UK ILL2546-A STATIC PRESSURE (Pa) Airflow 80% De-rate 6,830 6,640 6,270 5,930 5,600 Airflow 90% De-rate 7,150 7,060 6,850 6,590 6,330 CW-80T STANDARD AUSTRALIA, EUROPE, SOUTH AFRICA & UK ILL2548-A STATIC PRESSURE (Pa) Airflow 80% De-rate 24,590 23,900 22,570 21,350 20,160 Airflow 90% De-rate 25,740 25,420 24,660 23,720 22,790 6 of 8 ES E120-B AU1804
7 CW-80T HICAP AUSTRALIA, EUROPE, SOUTH AFRICA & UK ILL2547-A STATIC PRESSURE (Pa) Airflow 85% De-rate 7,400 6,870 6,430 5,960 CW-80T HICAP AUSTRALIA, EUROPE, SOUTH AFRICA & UK ILL2549-A STATIC PRESSURE (Pa) Airflow 85% De-rate 26,640 24,730 23,150 21,460 7 of 8 ES E120-B AU1804
8 NOTES: THIS PAGE LEFT INTENTIONALLY BLANK 8 of 8 ES E120-B AU1804
TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture
More informationTECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO
GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture
More informationIndirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)
Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.
More informationIndirect Evaporative Air Conditioning
Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient
More informationIndirect Evaporative Air Conditioning
Indirect Evaporative Air Conditioning World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing ingenious, energy-efficient
More informationFACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air
FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air About Climate Wizard Climate Wizard is an air conditioner that uses an indirect evaporative heat transfer core that provides
More informationFACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air
FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioner 100% outside air About Climate Wizard Climate Wizard is an air conditioner that uses an indirect evaporative heat transfer core that provides
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More informationCOOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw
COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationRemote Air Cooled Condensers C2 Series
Remote Air Cooled Condensers C2 Series High Fan Speed Capacity 236kW Low Fan Speed Capacity 1740kW 180kW 1257kW Innovative Heat Transfer Solutions Issue date 04/14 APPLICATION BENEFITS / FEATURES HIGH
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationROOFMASTER STEF-HT ROOF FAN
fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT... 3 Performance Data... 4 Performance Table... 5 General description... 6 Fan Chart-explanation
More informationEnviroMagic. Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications
EnviroMagic Low profile, ultra-high efficiency evaporative cooling for commercial and industrial applications World leading climate control solutions Seeley International is Australia s largest air conditioning
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationSeries. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater
SUPPLY UNITS Series VENTS PA E Series VENTS PA W A13 control panel A13 control panel Suspended air supply units with the air capacity up to 3350 m 3 /h in the sound- and heat-insulated casing with the
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More information4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB
4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationSpecification Data. General:
Specification Data General: Zone Units (ACU s) will be draw through vertical type having double skin construction. All Zone Units will have all necessary components such as control valves and motors to
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationPremium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units
Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to
More informationENERGY RECOVERY VENTILATION (ERV)
Home/Other Products/Obsolete Ranges ENERGY RECOVERY VENTILATION (ERV) 2 model sizes covering 500 to 1500m3/hr Choice of 90% or 55% efficient aluminium energy recovery cell High performance EC/DC motors
More informationVENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС
HEAT RECOVERY AIR HANDLING UNITS Series VUT R TN H ЕС VUT R TN EH ЕС HEAT-RECOVERY VENTILATION Two-Stage Energy Saving System: HEATING COOLING Stage 1: Heat energy recovery by means of the rotary heat
More informationSystem Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.
High Density Presicion Cooling Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons System 2100 Kompact www.compu-aire.com CA A - 8 34 -K System 2100 K Type Air Cooled - A Chilled Water Cooled - C
More informationOWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)
OWNER S MANUAL Evaporative Cooler (English) (LCB, CPL, CPS, BM) Original English Instructions TABLE OF CONTENTS INTRODUCTION 4 WALL CONTROL FUNCTIONS 5 STARTING YOUR COOLER 5 AUTOMATIC MODE 6 MANUAL MODE
More informationCOMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems
COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems World leading climate control solutions Seeley International is Australia s largest air conditioning manufacturer and a global leader in developing
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationfor a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the
More informationNEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning
: Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationCommercial and Industrial Cooling. World-leading natural cooling technology
Commercial and Industrial Cooling World-leading natural cooling technology Why Breezair? How evaporative air conditioning works The beauty of evaporative air conditioning is its simplicity. It s a process
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationSentinel Demand Energy Recovery Ventilation
Welcome to the world of Sentinel Demand Energy Recovery Ventilation Sentinel Totus 2 Demand Energy Recovery Ventilation (D-ERV) is a new heat recovery demand ventilation system designed to meet modern
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationAir handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation
Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique
More informationTVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1
TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system
More informationCOOLflow 4E PRODUCT RANGE
COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed
More informationGHE Dehumidifiers for radiant cooling systems with heat recovery
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationMAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY
MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation
More informationGHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationVEX100 series Air handling units with cross-flow heat exchanger
Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents
More informationSEQUENCE OF OPERATIONS
SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationOWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)
OWNER S MANUAL EXQ / EZQ / EXS Evaporative Coolers (English) Original English Instructions Hello and congratulations on purchasing a Breezair evaporative cooler for your home. At Seeley International
More informationContents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...
Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5
More information30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +
Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new
More informationThe new Xcell EC High Efficiency Range Fresh air pure and simple
The new Xcell EC High Efficiency Range Fresh air pure and simple The new Xpelair saving energy, saving money 2 www.xpelair.co.uk Introducing the NEW Xpelair Xcell EC High Efficiency range. The Xcell EC
More informationExhaust Duct Design Page 1 of (C)
Exhaust Duct Design Page 1 of 16 2016-10-07 (C) Oven Exhaust Guide Version: R5 Exhaust Duct Design The following section is for your guidance in establishing a design to suit your Exhaust duct design requirements.
More informationCoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor
CoolTeg Plus XC40 AC-TXC Direct expansion Air-conditioning unit with integrated compressor Application CoolTeg Plus XC40 is a revolutionary air-conditioning unit specifically designed for installation
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationFresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.
Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is
More informationEnergy. The Energy ducted units have been designed. Heat Recovery Unit
Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc.,
More informationPRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h
PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationSmall Room Heat Recovery Ventilation
Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room
More informationPanther Fan Coil Unit
Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationNew rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018
New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1 Extensive option package included in all models ErP compliant 2018 3 years warranty Daikin rooftops Flexible to suit your application Rooftop for Retail & Department
More informationNEXT DL NEXT DL. rcgroupairconditioning
NEXT DL: Close control air conditioners with displacement air delivery with remote condenser, or built in water cooled condenser or for chilled water feeding Cooling capacity: 7,7 51,4 NEXT DL rcgroupairconditioning
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationEC Motor Fan Coil Units. IMD-Y Series l/s
EC Motor Fan Coil Units IMD-Y Series 45 235 l/s Temperzone s Fan Coil History Temperzone have been manufacturing chilled water fan coil units for more than 45 years. Company Profile Temperzone Limited
More informationTECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:
Biddle Air Systems Limited St. Mary s Road, Nuneaton,Warwickshire CV AU. Tel: + 0 78 Fax: + 0 77 Email: sales@biddle-air.co.uk http://www.biddle-air.co.uk F.H. Biddle B.V. P. O. Box, NL-988 ZG Kootstertille,The
More informationOWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY
OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EXH, EZH) Introduction...4 Remote Thermostat Control...5 Wall Mounted Thermostat Control...11
More informationVTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...
. - B 97 Product Detail... B98 Benefits... B100 Construction Details... B102 Custom Features and Options... B103 Accessories... B Engineering Data... B107 Structural Support... B111 Engineering Specifications...
More informationHealthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.
PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130
More information30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation
Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed
More informationINDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying
INDUSTRIAL DEHUMIDIFIERS Advanced range of compressor and desiccant dehumidifiers Dehumidification and drying To room From room Fan Regeneration heater Dry process air Regeneration air Regeneration area
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationAPPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.
APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2 1,3-6,6 kw ARIA2-AGU-1610-E www.lennoxemea.com INDEX ARIA 2 APPLICATION GUIDE Ref : ARIA2-AGU-1610-E General rules for installation Performance Guidelines Confi
More informationThe PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications
Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationCUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams
Integrated chilled beams Key figures Connections: 1x mm, 2x mm Airflow: 5-60 l/s Pressure range: 40 - Pa Size: 293 x 200 mm (WxH) Length: 1192 or 1792 mm Total effect: up to 1200W Cumulus is available
More informationINTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation
JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed
More informationHIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%
Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and
More informationTechnical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging
Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013
More informationCassette units Model Comfort Circle. - heating - cooling - ventilation
Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their
More informationCXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability
CXAV / CGAV Trane Module Industry top class efficiency and reliability Trane Module Adopts resin coated blue fins Design registration n pending High-efficiency, high-durability and space-saving Resin coated
More informationThe PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications
Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationDaikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel
Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent
More informationOWNER S MANUAL. Evaporative Cooler. (English) (EA, EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY
OWNER S MANUAL Evaporative Cooler REMOTE CONTROL AUTO COOL FAN SPEED PM ECONOMY ILL239-D ILL1140-A (English) (EA, EXH, EZH) Hello and congratulations on purchasing a Breezair Ducted Cooler for your home.
More informationAIR HANDLING UNITS MANDÍK
AIR HANDLING UNITS MANDÍK 2 CONTENTS MANDÍK, a. s. The Company... 3 Photo Gallery... 4 Unit Description... 6 Air handling unit parameters according to Eurovent... 7 Product Range of the Air Handling Units...
More informationFRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %
FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationClosed Circuit Cooling Towers
VFL - C 35 Closed Circuit Cooling Towers Product Detail VFL Closed Circuit Cooling Tower... C36 Benefits... C38 Construction Details... C40 Custom Features and Options... C41 Accessories... C43 Engineering
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationCondensing Units CUS 15-60
Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....
More information