Solar heating systems

Size: px
Start display at page:

Download "Solar heating systems"

Transcription

1

2 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back system Hydraulic units high efficiency Hydraulic pumping units with integrated control Hydraulic pumping units without regulation Hydraulic units for major installations OKFRESH - Fresh water station Indirect heat exchange solar kit Solar dhw kit Zone valves Safety valves Flowmeters Safety groups Compensation valves Drain valves/air separators Mixing valves Controls for solar heating installations Solar expansion vessels Accessories for expansion vessels 03

3 SOLAR HEATING SYSTEMS COMPACT, "ALL-IN-ONE" SOLAR SYSTEM This is an ALL-IN-ONE solar system that uses solar thermal energy to heat domestic water. It integrates the absorber, the pump-circulated system, and the 150l tank. It uses a PV-driven circulating pump, which means it is a fully autonomous system that does not require any external power source. COMPONENTS All you need in just a single element Inlet. 1 6 Pump. 2 7 PV panel. 3 8 Methacrylate cover. 4 9 Insulator. Valve. Outlet. Exchanger sqm stainless steel collector featuring a blue selective surface litres tank made of corrosion-resistant composite materials. 2 1 HOW DOES IT WORK? From sunrise till water is hot. 85º STAGE 1 Solar radiation reaches the collector, which concentrates the heat that is then transferred to the heat transfer fluid that circulates through the system. The selective treatment and the shape of the surface, it uses a large proportion of incident radiation. As it is filled with the heat transfer fluid, it can use 100% of the surface. STAGE 2 The radiation on the surface is also received on the PV panel, which generates the power that drives the circulating pump. The pump gets the hot fluid into the exchanger. STAGE 3 The heat is transferred to the tank because the hot fluid passes from the pump to the exchanger. The tank will get hot whenever there is sunlight up to the top limit set at 85ºC. 84 Tel.: Fax:

4 WHERE IS IT INSTALLED? It can be adapted to meet different installation needs The ALL-IN-ONE solar system can be placed anywhere requiring domestic hot water (homes, campsites, community vegetable gardens, country homes and hotels). The ALL-IN-ONE solar system can be placed in a wide variety of places, from a pitched roof (either built-in or not) to a flat surface, a garden or a wall. 03 Tel.: Fax:

5 SOLAR HEATING SYSTEMS ADVANTAGES 15% CHEAPER THAN OTHER SYSTEMS OF THE MARKET Less components means less time to install less final price and more m 2 available at home. COMPONENTS TO INSTALL A SOLAR SYSTEM COMPONENTS SYSTEM DRAIN BACK SYSTEM OKSOL SYSTEM ORKLI ALL-IN-ONE MATERIAL Collector Hydraulic group Tank Solar tube Secondary tube ACCESSORIES ELECTRIC INSTALLATION Structure 45º Expansion tank Sanitary solar fluid Drain valves Electrical legalization Material and labor INSTALLATION TIME 25,5 h. 15,5 h. 9,5 h. COMPONENT SYSTEM OKSOL SYSTEM 86 Tel.: Fax:

6 Pump powered by photovoltaic cell. Storage capacity: 150 litres. Useful collection surface area: 1,95 m 2. Heat exchanger surface: 0,29 m 2. External dimensions: - Length: 2029 mm. - Width: 1020 mm. - Depth: 250 mm. - Empty weight including tank: 80 kg. Structure on floor or flat terrace, structure, sloping roof top structure and wall structure, under request. 03 Solar collector with integrated tank OKSOL Tel.: Fax:

7 SOLAR HEATING SYSTEMS STRUCTURES Wall structure V Roof-integrated structure V Non-perforating anchor kit V Sloping roof top structure V (Non-perforatin anchor kit not included) Structure on floor or flat terrace (legs) V Tel.: Fax:

8 ACCESSORIES Protective awning Centrifugal pump Centrifugal pump V Protective awning V Non-return valve 3-bar safety valve 03 Non-return valve V bar safety valve V P+5 safety valve Heat-carrying fluid (16 litre tank) P+T safety valve V Heat-carrying fluid V Tel.: Fax:

9 SOLAR HEATING SYSTEMS SOLAR PANEL FOR SWIMMING POOLS Heated pool water almost all year round. An efficient, affordable alternative. This is one of the most technically efficient, cost-effective applications for swimming pool water heating. Your pool season is extended by 2-3 months with this solar panel system, as the process involves heating large amounts of water to a relatively low temperature. A solution using solar power: a clean, free, inexhaustible power source to keep your pool water at just the right temperature. FEATURES Stainless steel solar collector. Collection surface area 2 m² and weight 15 Kg. 3 hydraulic connections (Ø ¾) for any installation configuration. Dimensions 2000 x 1000 x 18. Sold in batches of 4 units. Panels guaranteed for 5 years ISO G 3/4" Tel.: Fax:

10 HOW DOES IT WORK? 03 ADVANTAGES It extends the pool season by 2-3 months (at temperatures over 25ºC) The system is compatible with other auxiliary pool heating. Excess heat can be used for domestic hot water production, via a heat exchanger. Adaptable to all kinds of pool. The system is connected to the existing filter circuit using a heat exchanger or directly, depending on the type of filtering. Totally controllable via a central control unit. It enables the pool temperature to be controlled and the solar collector system to be switched off when the water reaches the desired temperature. A smaller heating surface area is required compared to other on the market. Tel.: Fax:

11 SOLAR HEATING SYSTEMS SOLAR PANEL FOR SWIMMING POOLS Absorber type: Stainless steel absorber with selective coating. Dimensions: Length 2000 mm ± 1 mm, width 1000 mm ± 0.5 mm. Surface: 2 m 2. Aperture surface: 1.95 m 2. Weight: 19 kg. Interior volume: 32 litres. Connection openings ISO G 3/4. Pressure control resistance: 6 bar. Maximum working pressure: 3 bar. Nominal flow: 90 l/h m 2. Solar panel for swimming pools V HYDRAULIC CHARACTERISTICS Pressure drop mmca l/min 92 Tel.: Fax:

12 ALL THE HYDRAULIC COMPONENTS REQUIRED FOR A SOLAR INSTALLATION Air vent valve with ball valve Solar hydraulic pump units (or Drain-back system) Collectors field 03 Solar expansion vessels Support system Boiler Swimming pool Zone valve Drain valves with air separators Solar DHW kit Hot water tank Tel.: Fax:

13 SOLAR HEATING SYSTEMS DRAIN UNIT: HYDRAULIC UNIT WITH DRAIN-BACK SYSTEM A solution to prevent overheating and freezing. ADVANTAGES BIGGER SAVINGS simply select all the components you need COMPATIBLE with all the collectors, heat exchangers and regulators on the market For INSTALLATIONS with a larger number of collectors than other market alternatives HOW DOES IT WORK? System off - Collectors empty OFF Maximum temperatures OFF System off - Collectors empty (no danger of vaporisation) OFF OFF ON ON System start-up - Filling circuit temperatures -0ºC System off - Collectors empty (no danger of freezing) OFF OFF ON System running - Forced circulation OFF 94 Tel.: Fax:

14 SELECTION GUIDE The Drain-Unit selection is determined by the height of the installation. Bear in mind the difference in height between the top of the collector array and the bottom part of the Drain-Unit positioning. N.b.: less pump power required if the Drain-Unit is installed just above the collector field. HEIGHT OF INSTALLATION* 3-5 metres 5-10 metres metres 3-10 metres metres RECOMMENDED MODEL 6-metre pumps 6-metre + 6-metre pumps metre pumps 11-metre pumps metre pumps ECONOMY MODEL 6-metre pumps 11-metre pumps Unfit 11-metre pumps metre pumps NUMBER OF COLLECTORS** *Height from the top of the solar collectors to the lowest point of the drain unit **Calculated for a collector capacity of 1.25 litres and tube 15 mm. It can be used with installations that have a larger number of collectors than other market alternatives. The volume of the circuit above the drain unit must not exceed 8 litres of working volume of the air separator in drain units with a single tank (or 16 litres for drain units with 2 tanks). Volume calculation in upper part: Volume Nº of collectors Volume of fluid = + + in collector Volume of pipes 03 DRAIN UNIT WITH INTEGRATED REGULATION Maximum operating temperature: 110ºC. Maximum peaks: 130ºC. Safety valve calibration: 3 bar. Flow indication range: 2-12 litres/min. Maximum separation volume: 8 litres. Connections: bicone nut for a Cu15mm o ½ M pipe. Control options with pre-connections made. Consult for adaptability to other regulations. TWO 6-metre PUMPS PUMPS REGULATION ARTICLE 6 metres + 6 metres Basic (3 sensors, 1 relay) 74110BA 6 metres + 6 metres Vision (6 sensors, 3 relays) 74110VI Tel.: Fax:

15 SOLAR HEATING SYSTEMS DRAIN UNIT WITH INTEGRATED REGULATION ONE 11-metre PUMP PUMPS REGULATION ARTICLE 11 metres Basic (3 sensors, 1 relay) 74200BA 11 metres Vision (6 sensors, 3 relays) 74200VI ONE 6-metre PUMP PUMPS REGULATION ARTICLE 6 metres Basic (3 sensors, 1 relay) 74100BA 6 metres Vision (6 sensors, 3 relays) 74100VI 96 Tel.: Fax:

16 DRAIN UNIT WITH INTEGRATED REGULATION TWO 11+6-metre PUMPS 03 PUMPS REGULATION ARTICLE 11 metres + 6 metres Basic (3 sensors, 1 relay) 74210BA 11 metres + 6 metres Vision (6 sensors, 3 relays) 74210VI DRAIN UNIT WITHOUT REGULATION Maximum operating temperature: 110ºC. Maximum peaks: 130ºC. Safety valve calibration: 3 bar. Flow indication range: 2-12 litres/min. Maximum separation volume: 8 litres. Connections: bicone nut for a Cu15mm o ½ M pipe. Consult for adaptability to other regulations. Recommended characteristics: Solar regulation with a differential relay. Maximum temperature function of collector 110ºC. (recommended). Difference in activation temperature 10-15ºC.(recommended). PUMPS REGULATION ARTICLE 6 metres + 6 metres metres metres metres + 6 metres Tel.: Fax:

17 SOLAR HEATING SYSTEMS For installations with twice as many solar collectors as the existing system. DRAIN UNIT: NEW HYDRAULIC UNIT WITH DRAIN BACK SYSTEM Maximum operating temperature: 110ºC. Maximum peaks: 130ºC. Safety valve calibration: 3 bar. Flow indication range: 2-12 litres/min. Maximum separation volume: 16 litres. Connections: bicone nut for a Cu15mm o ½ M pipe. Control options with pre-connections made. Consult for adaptability to other regulations. ONE 11-metre PUMPS In case of no regulation options, the regulation must comply with the following characteristics: - Solar regulation with a differential relay. - Maximum temperature function of collector 110ºC. (recommended). - Difference in activation temperature 10-15ºC.(recommended). PUMPS REGULATION ARTICLE 11 metres Basic (3 sensors, 1 relay) 74200BADO 11 metres Vision (6 sensors, 3 relays) 74200VIDO 11 metres NO 74200DO 98 Tel.: Fax:

18 DRAIN UNIT: NEW HYDRAULIC UNIT WITH DRAIN BACK SYSTEM TWO 11+6-metre PUMPS 03 PUMPS REGULATION ARTICLE 11 metres + 6 metres Basic (3 sensors, 1 relay) 74210BADO 11 metres + 6 metres Vision (6 sensors, 3 relays) 74210VIDO 11 metres + 6 metres NO 74210DO Drainback tank extension kit Tank V Tel.: Fax:

19 SOLAR HEATING SYSTEMS HYDRAULIC UNITS HIGH EFFICIENCY The optimum efficiency of the sun as a power source The SolarOrkli line opts for technologically innovative products contributing to smarter, more sustainable consumption of renewable energies. An example are the high-efficiency solar hydraulic units, which include components that can increase energy efficiency by almost 50%. 100 Tel.: Fax:

20 HYDRAULIC UNITS HIGH EFFICIENCY Maximum working temperature in flow branch: 120ºC. Maximum working temperature in return branch: 100ºC. Maximum working temperature of safety valve: 160ºC. Safety valve calibration: 6 bar. Thermometer temperature range: 0-120ºC. Flow meter indication range: 2-12 l/min. (visual flow meter); 2-40 l/min. (electronic). High energy efficiency pump with cabling preconnection. External PWM pump modulation. Hydraulic unit for solar collector fields up to 16 m 2. Consult for adaptability to other regulations. Pump consumption range: 4-60W. Energy count option on models with electronic sensors. Manometer scale: 0-10 bar. Connections: 3/4"H. Branch distance: 95 mm. Regulation with connections made. EPP insulation HYDRAULICS PUMP CLIMATE CONTROL ELECTRONIC FLOW EXPANSION ARTICLE BASIC HE TEMPERATURE AND VESSEL JOINT PRESSURE SENSORS ACCESSORIES Complete Yonos Para ST 15/7 PWM YES YES YES 73140BAHE Complete Yonos Para ST 15/7 PWM YES NO YES 73100BAHE Complete Yonos Para ST 15/7 PWM YES YES NO 73040BAHE Complete Yonos Para ST 15/7 PWM YES NO NO 73000BAHE Complete Yonos Para ST 15/7 PWM NO YES YES 73140HE Complete Yonos Para ST 15/7 PWM NO NO YES 73100HE Complete Yonos Para ST 15/7 PWM NO YES NO 73040HE Complete Yonos Para ST 15/7 PWM NO NO NO 73000HE Tel.: Fax:

21 SOLAR HEATING SYSTEMS HYDRAULIC PUMPING UNITS WITH INTEGRATED CONTROL Maximum operating temperature in flow branch: 160ºC Flow indication range: 2-12 l/min. Maximum operating temperature in return branch: 110ºC. Manometer scale: 0-10 bar. Maximum operating temperature in safety valve: 160ºC. Connections: 3/4 H. Hydraulic unit for collector fields of up to 16 m 2. Distance between branches: 95 mm. Safety valve calibration: 6 bar Control with connections made. Thermometer temperature range: 0-120ºC. Consult for adaptability to other regulations. + HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE FLOW RETURN VESSEL JOINT BRANCH BRANCH ACCESSORIES Complete Complete ST 15/6eco Basic (3 inputs, 1 relay) NO 70000BA Complete Complete ST 15/6eco Vision (6 inputs, 3 relays) NO 70000VI Complete Complete ST 15/6eco Basic (3 inputs, 1 relay) YES 70100BA Complete Complete ST 15/6eco Vision (6 inputs, 3 relay) YES 70100VI Note: Consult pump curves. + Note: Consult pump curves. HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE FLOW RETURN VESSEL JOINT BRANCH BRANCH ACCESSORIES NO Complete ST 15/6eco Basic (3 inputs, 1 relay) NO 70020BA NO Complete ST 15/6eco Vision (6 inputs, 3 relays) NO 70020VI NO Complete ST 15/6eco Basic (3 inputs, 1 relay) YES 70120BA NO Complete ST 15/6eco Vision (6 inputs, 3 relays) YES 70120VI 102 Tel.: Fax:

22 HYDRAULIC PUMPING UNITS WITHOUT REGULATION Maximum operating temperature in flow branch: 160ºC Maximum operating temperature in return branch: 110ºC. Maximum operating temperature in safety valve: 160ºC. Hydraulic unit for collector fields of up to 16 m 2. Safety valve calibration: 6 bar. Consult for adaptability to other regulations. Thermometer temperature range: 0-120ºC. Flow indication range: 2-12 l/min. Manometer scale: 0-10 bar. Connections: 3/4 H. Distance between branches: 95 mm HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE FLOW RETURN VESSEL JOINT BRANCH BRANCH ACCESSORIES Complete Complete ST 15/6eco NO NO Complete Complete ST 15/6eco NO YES Note: Consult pump curves. + HYDRAULICS PUMP* CLIMATE CONTROL EXPANSION ARTICLE FLOW RETURN VESSEL JOINT BRANCH BRANCH ACCESSORIES No Complete ST 15/6eco NO NO No Complete ST 15/6eco NO YES Note: Consult pump curves. Tel.: Fax:

23 SOLAR HEATING SYSTEMS HYDRAULIC UNITS FOR MAJOR INSTALLATIONS FOR COLLECTOR FIELDS OF UP TO 50 M 2 SAVINGS! 70% SAVINGS ON LABOUR COSTS FOR COMPONENT INSTALLATION ALL HYDRAULIC COMPONENTS PRE-ASSEMBLED 104 Tel.: Fax:

24 HYDRAULIC UNITS FOR MAJOR INSTALLATIONS Maximum operating temperature in flow branch: 160ºC. Maximum temperature in return branch: 110ºC. Maximum temperature of safety valve: 160ºC. Hydraulic unit for collector fields of up to 50 m 2. Safety valve calibration: 6 bar. Thermometer temperature range: 0-120ºC. Flow indication range: 5-40l/min. Manometer scale: 0-10 bar. Distance between branches: 125mm. Connections: 1 1/4" for flexible pipe DN25 and bicone nut for a pipe Cu 28mm. Connection for expansion vessel: ¾ M. Consult for adaptability to other regulations. 03 PUMP PIPE Cu28 JOINT ACCESSORIES ARTICLE TOP S (13 metres) NO TOP S (13 metres) YES Tel.: Fax:

25 SOLAR HEATING SYSTEMS HYDRAULIC CHARACTERISTICS HYDRAULIC UNITS HIGH EFFICIENCY External control via PWM H/m p/kpa 4660/ 5 PWM1 / 95 PWM2 Wilo-Yonos PARA ST /15 PWM1 /85 PWM2 15/7.0, 25/7.0, 30/7.0 1~230 V - Rp ½, Rp 1, Rp 1 ¼ n-1/min/%pwm 1/% PWM /25 PWM1 /75 PWM /35 PWM1 /65 PWM /45 PWM1 /55 PWM2 max /55 PWM1 /45 PWM /65 PWM1 /35 PWM2 1283/75 PWM1 /25 PWM /85 PWM1 /15 PWM ,5 1,0 1,5 2,0 2,5 3,0 Q/m 3 /h Q/l/s Q/lgpm p 1 /W 40 max ,5 1,0 1,5 2,0 2,5 3,0 Q/m 3 /h Tolerances of each curve according to EN : Tel.: Fax:

26 ST15/6 ECO 6 5 Head (m) ,5 1 1,5 2 2,5 3 3 Water flow (m 3 /h) Top S Flow height (m) min. máx. 0 0,4 0,8 1,2 1,6 2 2,4 2,8 3,2 (m 3 /h) Tel.: Fax:

27 SOLAR HEATING SYSTEMS OKFRESH - Fresh Water Station Instant hot water whenever you need it The Fresh Water Station is a system that guarantees instant hot water whenever it is required, at just the right temperature. This system guarantees coverage of your domestic hot water needs, avoiding any hygiene or power loss problems connected with domestic hot water storage. With its instant hot water principle, Orkli's Fresh Water Station is the ideal system for use in homes, residences or sports complexes, and it is perfect for use with renewable energy heating installations. It is simple to install and can be easily adapted to the users' requirements. COMPONENTS DCW inlet Primary circuit outlet DHW circulation system Flow switch in DCW inlet. (To activate the pump when DHW is demanded) Plate heat exchanger Heating circulation HE pump DHW outlet temperature sensor Primary circuit intlet Mixing 3 ways valve (It controlles DHW outlet temperature, using a distance sensor that acts on the primary water circuit) DHW outlet 108 Tel.: Fax:

28 Instantaneous domestic hot water production. Stainless steel 90 kw heat exchanger. Domestic hot water production capacity 30 l/min. or 20 l/min. (depending on the number of heat exchanger plates). Flow meter activation = 2 l/min. DHW temperature controlled by a thermostatic valve acting on the primary circuit's 3-way mixing valve to regulate the heat exchanger flow. Ensures a low return temperature of the water in the primary circuit (to aid stratification). Connection for an optional DHW circulating system available. The highest temperature is concentrated in the component in the lowest location so that the heat is naturally transferred to the top part of the heat exchanger, cooling down the hot zone and preventing problems with scale. Available in July 03 Fresh Water Station S Tel.: Fax:

29 SOLAR HEATING SYSTEMS INDIRECT HEAT EXCHANGE SOLAR KIT The indirect heat exchange solar kit is designed for centralised solar heating installations with distributed back-up power. Each home has an individual back-up power source and its own interior distribution circuit supplying domestic water. This kit regulates the recirculation inlet to the home from the circuit previously heated by the solar collector. If the kit detects that a tap has been turned on and hot water is required, the flow to the heat exchanger is opened to preheat the domestic water inlet. When the hot water tap is turned off, the 3-way valve opens the bypass again and shuts off the flow to the heat exchanger. The shut-off valves allow the central recirculation system to be completely blocked off at all the inlets. Fastening template Heat exchanger Heating output Heating input HWR input HWR output 3 ways valves Hydraulic valve 110 Tel.: Fax:

30 did you know? that if you wish you may complete the totally regulated installation with the solar domestic water kit? If there is no DHW demand: If there is DHW demand: Heating output Heating input HWR output HWR input Heating output Heating input HWR output HWR input 03 Dimensions: 350 x 308 x 115 mm. Heat exchanger power: 35KW. Activation flow: 2L/min. Maximum HWR operating flow: 15L/min. Maximum heating operating flow: 20L/min. Maximum HWR pressure: 15bar. Maximum heating temperature: 70ºC. Connections: ¾ M. Solar Kit S HYDRAULIC CHARACTERISTICS Hot water circuit Heating H (m) H (m) Flow (L/h) Flow (L/h) Hot water circuit Circuit bypass Circuit heat exchanger Tel.: Fax:

31 SOLAR HEATING SYSTEMS SOLAR DHW KIT A universal kit for connecting a solar hot water tank to a conventional domestic hot water source Unit for connection to the auxiliary domestic water heating units installed between the solar water tank and this back-up power source, normally an instant water heater or a gas or electric water heater. It includes a 3-way valve, which determines whether the water from the solar water tank should be conveyed via the back-up power source or can be directly sent on for consumption, and a mixing valve regulating the outlet temperature of the domestic hot water in the solar heating + conventional back-up system. Solar hot water tank Domestic hot water outlet From the solar collector field Mains water connection Return to the solar collector field 112 Tel.: Fax:

32 Hydraulic diagram: If water in solar hot water tank >48ºC If water in solar hot water tank <48ºC Domestic hot water outlet Mains water connection From the solar hot water tank >48ºC Domestic hot water outlet Mains water connection From the solar hot water tank <48ºC 03 SOLAR DHW KIT Valve material: brass, according to EN12165 standard. Closure gasket material: EPDM. Connections: ½, or 15 mm copper pipes. Maximum operating temperature: 90ºC. Maximum operating pressure: 10 bar. Calibration of 3-way valve/bypass temperature: 48ºC. Bypass temperature tolerance: +-2ºC. Thermostatic mixer regulation range: 30-60ºC. Mixing outlet temperature calibration: 45ºC. Components suitable for use with domestic water. Solar dhw kit S Tel.: Fax:

33 SOLAR HEATING SYSTEMS ZONE VALVES To be used in solar system primary circuits. Fluid: water with glicol up to 50%. 2 ways - Without run-end micro: 3 wires improvements More robust transmission Fluid temperature -20ºC - 160ºC. Normally closed in A. 2 ways - With run-end micro: 5 wires improvements More robust transmission 1/2" /4" " /2" /4" " ways - Without run-end micro: 3 wires improvements More robust transmission 3 ways - With run-end micro: 5 wires improvements More robust transmission 1/2" /2" /4" /4" " " M-M SOLAR ZONE VALVES 2 ways - Without run-end micro: 3 wires M-M improvements More robust transmission 2 ways - With run-end micro: 5 wires M-M improvements More robust transmission 3/4" " " ways - Without run-end micro: 3 wires M-M improvements More robust transmission 3 ways - With run-end micro: 5 wires M-M improvements More robust transmission 3/4" " " Note: Same discount as zone valves section. 114 Tel.: Fax:

34 SAFETY VALVES Safety valve for solar installation primary circuits. Suitable for working with 50% water-glycol mixture. Maximum operating temperature: 160ºC. Solar safety valve certification: TÜV SV SOL 50 Consult for other setting options. Note: Same discount as valves and safety groups section. FLOWMETERS Flow indication range:5/40 l/m y 2-12 l/m. Includes: filling/emptying tap. Maximum operating temperature: 110ºC. Flow regulation. Vertical installation. Suitable for use with 50% water/glycol mix. 1/2"F - 3/4"F (3 bar) /2"F - 3/4"F (4 bar) /2"F - 3/4"F (6 bar) /2"F - 3/4"F (8 bar) /2"F - 3/4"F (10 bar) /4" F - 1" F (loose nut) / 2-12 l/m E /4" F - 1 1/2" F (loose nut) / 2-12 l/m E /4" M - 1 1/2" F (loose nut) / 5-40 l/m E SAFETY GROUPS Set a 7 bar. Featuring: - Locking tap. - Purging or vacuum device. - Antireturn device. To be used in solar system primary circuits. Straight orientation AISI 302 stainless steel valve spring. Chemical-nickel treated brass valve shaft. To be assembled outside. Special plastic omponents for UV rays. 3/4" /4" with adaptor to 1/2" Note: Same discount as valves and safety groups section. COMPENSATION VALVES Designed to work outdoors. Stainless steel spring. Plastic lever adapted to resist UV rays. 1/2" - 7K /4" - 7K Tel.: Fax:

35 SOLAR HEATING SYSTEMS DRAIN VALVES/AIR SEPARATORS Automatic drain valve Maximum operating temperature 150ºC. Suitable for working with water-glycol mixture. Maximum operating pressure 6 bar. Air separator Maximum operating temperature 150ºC. Suitable for working with water-glycol mixture. Maximum operating pressure 6 bar. To be installed in horizontal lines. 3/8" (to be installed with ball valve) E /8 with accessories for 22 mm Cu pipe E /8" air vent valve with ball valve E MIXING VALVES Thermostatic mixing valves for domestic water Include two filters and two antireturns at the inlet and outlet. Kv 1,5 m 3 /h. 3/4" M E /2" M without nuts E /2" H without nuts, 2 ball valves E CONTROLS FOR SOLAR HEATING INSTALLATIONS Controls for solar heating installation primary circuits. Temperature sensors included. 3 inputs, 1 relay. 6 inputs, 3 relays. Diagrams with: - Two collector fields, 2 pumps. - 1 Pump + zone valve; two accumulators. - 1 Pump + zone valve; two collector fields. 3 inputs, 1 relay and temperature limitation E inputs, 3 relays and temperature limitation E SOLAR EXPANSION VESSELS Maximum operating temperature 130ºC. Suitable for working with water-glycol mixture. Connection 3/4. Connection 1"M. 12 liters E liters E liters E liters E liters E liters E Tel.: Fax:

36 ACCESSORIES FOR EXPANSION VESSELS Includes: Wall fixing plate, 3-piece connector, flexible hose, rawlplugs, screws. 3/4" F connection E Tel.: Fax:

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

Solar Thermal Energy

Solar Thermal Energy Solar Thermal Energy INDEX Residential Applications Flat Plate Solar Collectors... 5 SOL 200 and SOL 200 H... 7 Mediterráneo 200... 8 Mediterráneo SLIM 200... 9 Hydraulic fittings and mounting systems...

More information

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05 THERMAL SOLAR ENERGY CATALOGUE OCTOBER 2008 INDEX RENEWABLE ENERGY THERMAL SOLAR ENERGY RENEWABLE ENERGY...pag. 05 SISTEMA CS 25 RN TAU... pag. 6 SISTEMA CS 25 RN - CS 25 RN PLUS... pag. 8 SISTEMA CSL

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

PRODUCT DEVELOPMENT INNOVATIVE SOLUTIONS

PRODUCT DEVELOPMENT INNOVATIVE SOLUTIONS PRODUCT DEVELOPMENT INNOVATIVE SOLUTIONS COMBUSTION SOLAR SYSTEMS HYDRAULIC A leading company 3 Orkli is a company with cooperative values. Its goal is to achieve profitability to the benefit of its customers

More information

Solar water heating system

Solar water heating system Solar water heating system Perhaps the most popular application of solar systems is for domestic water heating. The popularity of these systems is based on the fact that relatively simple systems are involved

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University Solar Water Heaters Bastián Acevedo Bustos Electronic Engineering Student, Tarapacá University Environmental Studies Student, York University Systems Active System Active systems use one or more pumps

More information

S SOLAR RANGE

S SOLAR RANGE GB S 002-02 SOLAR RANGE Solar collectors for on-roof installation Solar collectors for in-roof installation Roof mounting systems for on-roof installation Roof mounting systems for in-roof installation

More information

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. 8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature

More information

October Solar Thermal

October Solar Thermal October 2018 Solar Thermal Clima&Comfort RESIDENTIAL Settembre 2018 1 SOLAR THERMAL ERP Product in compliance with EU Regulations on Ecodesign* and Energy Labelling * Minimum efficiency limits on global

More information

INDIRECT SYSTEM FOR FROST LOCATIONS

INDIRECT SYSTEM FOR FROST LOCATIONS SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters

More information

T. +44 (0) E.

T. +44 (0) E. Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot

More information

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type 27-0514 VERTINOX AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type VERTINOX: THE RELIABLE HEART The boiler for hot sanitary water production is the heart of

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

Solar station DKP 6-8 / DKP Installation and Service Manual C

Solar station DKP 6-8 / DKP Installation and Service Manual C EN Solar station DKP 6-8 / DKP 9-20 Installation and Service Manual 300014274-001-C Contents 1 Introduction.............................................................................3 1.1 Used symbols...........................................................................................3

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

D O M E S T I C Solar Thermal

D O M E S T I C Solar Thermal DOMESTIC H E A T I N G Solar Thermal October 2017 SOLAR THERMAL ERP PRODUCT IN COMPLIANCE WITH EU REGULATIONS ON ESIGN* AND ENERGY LABELLING * Minimum efficiency limits on global primary energy consumption

More information

Gasketed and brazed plate heat exchangers

Gasketed and brazed plate heat exchangers Gasketed and brazed plate heat exchangers Contents Gasketed plate heat exchangers Options Brazed plate heat exchangers Options 14 22 30 32 www.fiorinigroup.it 11 Gasketed and brazed plate heat exchangers

More information

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE INSTRUCTION MANUAL INSTALLATION AND SERVICING AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE About this manual These installation and maintenance instructions contain important information

More information

Aquamatic Instantaneous DHW production unit with integrated storage tank

Aquamatic Instantaneous DHW production unit with integrated storage tank Aquamatic Instantaneous DHW production unit with integrated storage tank The Aquamatic is an innovative plug and play system, which unites both the functions of an inertial tank and an instantaneous DHW

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance

More information

The Meibes concept for the specialist: Easier. Quicker. More successful.

The Meibes concept for the specialist: Easier. Quicker. More successful. P R I C E L I S T 3 5 V A L I D F R O M 0 1. 0 1. 2 0 1 0...for the professional installer The Meibes concept for the specialist: Easier. Quicker. More successful. Easier Complete pre-assembled modules

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems Instruction Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN v 1.1 CONTENTS: 1 Introduction 3 2 Connection dimensions of CS TSV MIX Regulus 3 3 Function description of CS TSV

More information

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems www.regulus.eu CS TSV MIX-REGULUS Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN CS TSV MIX REGULUS CONTENTS: 1 Introduction 3 2 Connection dimensions

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

Commissioning a Solar Thermal Installation

Commissioning a Solar Thermal Installation OPERATING INSTRUCTIONS Wagner& Co Commissioning a Solar Thermal Installation Contents. Solar Circuit... 2. Commissioning... 3 3. Service Information... 4. Maintenance.... Solar Circuit Components Pipework

More information

Slide 1 Jul 20, 2006 Viessmann UK

Slide 1 Jul 20, 2006 Viessmann UK Slide 1 Jul 20, 2006 Viessmann UK Why use solar energy Global warming Fossil fuels Fuel price increases Green statement Slide 2 Jul 20, 2006 Viessmann UK Slide 3 Jul 20, 2006 Viessmann UK Choice of Collector

More information

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus. 24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers

More information

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY Hot Water Energy Storage HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY THE HOT WATER PEOPLE Hot Water Energy Storage THE HOT WATER PEOPLE Providing premium hot

More information

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL CodeNotes is provided courtesy of the ICC PMG Official Membership Council OFFICIAL CodeNotes Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction Solar

More information

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks Information Job Sheet 4 Closed-Loop Drainback Systems Drainback systems can consist of two closed-loop circuits. Each loop contains an active pump to circulate the solar and storage fluids independently.

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents

More information

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor) 1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor) 1. For year-round use, a collector tilt of degrees works best for a project located in Tampa, Florida.

More information

Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10

Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10 Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G1 Minus7 equipment and Systems are to be designed, installed and maintained by Minus7 personnel only. Contents General Description! 2

More information

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat C 223-01 made in Italy Nias Dual Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat GB Wall-hung boilers, forced draught, sealed chamber with

More information

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104 R8R Distribution and Regulation units Datasheet 08EN 0/09 R8RY0 R8RY0 R8RY0 R8RY0 Unit with insulation and actuator (optional) R8RY R8RY R8RY R8RY R8R distribution units control heating and cooling for

More information

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors VITOSOL Solar hot water heating systems Flat plate and vacuum tube solar collectors Solar energy can account for up to 70% or more of the energy required to heat the domestic hot water of an average family

More information

makes you independent Solar Technology

makes you independent Solar Technology Solar Technology www.fotolia.com We want you to be more than satisfied we want you to be excited! 2 Sun Heat free of charge! is inexhaustible is environmentally friendly www.fotolia.com 3 The Sun Heat

More information

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE Item 1) TWO THERMAL OIL HEATERS OF 1200 kw EACH 1.1) THERMAL OIL HEATER BODY Brand PIROBLOC Model GFT-060/40/H2 Power 1200 kw Delta Temperature 40 ºC Execution Horizontal Designed and built According AD-2000

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02

Installation, operation and care Wall-mounted electric boiler MP THL nr. - rev 02 Installation, operation and care Wall-mounted electric boiler MP 4 150206 THL nr. - rev 02 Contents Notes... 3 Safety and handling... 4 Operation... 5 Technical data... 6 Pipe installation... 8 System

More information

COMMERCIAL SOLAR SOLUTIONS

COMMERCIAL SOLAR SOLUTIONS Worldwide experience Biggest range of options Total package solutions 52 Commercial Solar NPT200 collectors provide hot water to Urbanest Student Accommodation Cleveland Street, Redfern NSW COMMERCIAL

More information

Evacuated Tube Solar Collector

Evacuated Tube Solar Collector Evacuated Tube Solar Collector Installation, commissioning and maintenance instructions Models: LHP20 LHP30 installation manual_lhp evacuated tube collector_december 2017 Page 0 CONTENTS 0 1 INTRODUCTION

More information

Frequently Asked Questions Solar Collector G24

Frequently Asked Questions Solar Collector G24 Frequently Asked Questions Solar Collector G24 The installation and use of the collector is very simple. Here we have tried to answer the questions we get very comprehensively, for those who would like

More information

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020

More information

C B SOLARTHERMAL. Solar thermal systems

C B SOLARTHERMAL. Solar thermal systems 66 66 Steca Elektronik GmbH 87700 Memmingen Germany Fon +49 (0) 81 8558-0 Fax +49 (0) 81 8558-12 www.stecasolar.com 67 E A D C B Legend: A Collector B Solar Station C Storage tank D Central-heating boiler

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS cyclone key advantages Cyclone... Responding rapidly to changing market expectations we have evolved the Joule Cyclone vented and unvented stainless

More information

TECHNICAL MANUAL FORCED CIRCULATION SYSTEMS

TECHNICAL MANUAL FORCED CIRCULATION SYSTEMS TECHNICAL MANUAL FORCED CIRCULATION SYSTEMS BOILERS SOLAR COLLECTORS HYDRAULIC KIT INTRODUCTION A company that proposes sunny solutions, working with passion and devotion, for three decades now, to always

More information

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................

More information

Protection and Control of Solid Fuel Boilers

Protection and Control of Solid Fuel Boilers Protection and Control of Solid Fuel Boilers thermal relief valves thermostatic valves and pump stations draft regulators www.regulus.eu BOILER PROTECTION AGAINST OVERHEATING Solid fuel boilers may get

More information

Condensing, pre-mixed, wall-hung gas boilers with water tank

Condensing, pre-mixed, wall-hung gas boilers with water tank C 271-01 made in Italy Nias condensing Condensing, pre-mixed, wall-hung gas boilers with water tank Life-enhancing heat GB Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING HIGH

More information

Data sheet: Wilo-RainSystem AF Comfort MC 304

Data sheet: Wilo-RainSystem AF Comfort MC 304 Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater

More information

LK Heat Exchanger Pack 10 -n

LK Heat Exchanger Pack 10 -n LK Heat Exchanger ack 10 -n 6 9 14 2 5 15 7 4 12 11 13 10 3 14 1 Design The LK Heat Exchanger ack -10 is primarily designed for glycol based under floor heating systems that must be isolated from other

More information

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU Installation, operation and maintenance Accumulator tank 1000, 750 and 500 litres Aqualux Teknik Aqualux B Aqualux 750 C Aqualux 750 Teknik with bivalent shunt, optional extra 2012-02-08 ver.: Supersedes:

More information

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DIRECT DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Heaters - Close Coupled & Split - Direct System direct

More information

60 C water temperature ensures thermal disinfection during hot water production

60 C water temperature ensures thermal disinfection during hot water production Product Catalog - Product Sheets Work smarter and get the complete overview of Danfoss Systems & Water Heaters for domestic hot water and district heating applications 60 C water temperature ensures thermal

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions Heat Accumulation thermal stores hot water storage tanks www.regulus.eu HOT WATER STORAGE TANKS WITH NO HEAT EXCHANGER R0BC Hot Water Storage Tanks Hot Water Storage Tanks permitting installation of an

More information

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM ATTACK SOLARTHERM, VAKUUMTHERM W W W. A T T A C K. S K SUN COLLECTORS water warming in swimming pools and sometimes as a support of heating in lowenergetic houses with lowtemperature heating system (floor,

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Roth fixed-value control set with high-efficiency pump

Roth fixed-value control set with high-efficiency pump Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical

More information

Exclusive Green E Condensing Wall-Hung Boilers

Exclusive Green E Condensing Wall-Hung Boilers Exclusive Green E Condensing Wall-Hung Boilers BERETTA HIGH-EFFICIENCY Residential Heating compliant XL Exclusive Green E Energy efficiency at its best EXCLUSIVE GREEN E is Beretta top of the range condensing

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Introduction...from 3 to 4 Tanks for the production and storage of DHW. Domestic use....from to 8 Tanks for the production and storage of DHW. Industr

Introduction...from 3 to 4 Tanks for the production and storage of DHW. Domestic use....from to 8 Tanks for the production and storage of DHW. Industr DH W HOT WATER TANKS FOR PRODUCTION AND STORAGE Domestic and Industrial uses Stainless Steel Tanks: Tank in tank, Coil and Storage Inertia Tanks for primary circuits TECHNICAL INFORMATION AENOR Empresa

More information

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas DATA SHEET: TDS101.4F 10-625kW R-SERIES YEAR ROUND MAXIMUM CONDENSING BOILER burning diesel oil, kerosene, natural gas or liquid petroleum gas 92% to 99.5% GCV efficiencies throughout the year Modulating,

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

30% Take lead on your project with an efficient system concept. lower energy.

30% Take lead on your project with an efficient system concept. lower energy. Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept 30% lower energy consumption by individual metering in each apartment www.evoflat.danfoss.com

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss. MAKING MODERN LIVING POSSIBLE Technical handbook Danfoss EvoFlat systems from A-Z Take lead on your project with an efficient system concept Safe and comfortable EvoFlat systems provide heating and domestic

More information

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES 1 1 2 3 Once again, the Energy Panel team has put all their excitement and enthusiasm to create this new publication. We want to make

More information

SOLAR HEATING SYSTEMS

SOLAR HEATING SYSTEMS introducing SOLAR HEATING SYSTEMS TM the low carbon water heating system June 2008 Irl 1 In this environmentally challenging world, it s time to rethink our heating.....while we still have time. There

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water Torrent ECO Open vented thermal store providing heating and mains pressure hot water SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS The final piece in your heating and hot water system What is a thermal

More information

4FLOOR-STANDING GAS CONDENSING BOILERS

4FLOOR-STANDING GAS CONDENSING BOILERS EASYLIFE PROJECT / SOLNEO / ECODENS RESIDENTIAL DTG (E) 130-15/25 Eco. NOx Plus DTG (E) 1300-15/25 Eco. NOx Plus/B150 DTG (E) 1300-15/25 Eco. NOx Plus/H150 DTG 1300-15/25 Eco. NOx Plus/V130 4FLOOR-STANDING

More information

Radiator Trap Radiator Valve

Radiator Trap Radiator Valve Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER

AGS 5/5E, AGS 10/10E INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS SOLAR PUMP STATIONS AGS 5/5E, AGS 0/0E FOR SEALED SOLAR HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER 7747006489.00-.SD CONTENTS CONTENTS Safety instructions

More information

maximise the sun s energy with warmflow solar Warmflow Solar

maximise the sun s energy with warmflow solar Warmflow Solar maximise the sun s energy with warmflow solar Warmflow Solar Warmflow Solar warmflow solar - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we

More information

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy Contact person RISE Björn Folkeson 2017-09-21 7P03972 1 (13) Energy and circular economy +46 10 516 54 46 bjorn.folkeson@ri.se Thermal Integration Ltd 8 Curzon Road Sudbury Suffolk CO10 2XW Great Britain

More information

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power

More information

Jaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks

Jaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks Jaspi GTV and Jaspi Oval thermal storage tanks Jaspi GTV thermal storage tanks Classy and efficient, the GTV tanks are suitable for new applications as well as heating system renovations for expanding

More information

DIGITAL MODULATING BOILERS

DIGITAL MODULATING BOILERS DIGITAL MODULATING BOILERS FOR HEATING AND SANITARY HOT WATER CMX15 CMX18 CM15 CM18 INSTALLATI INSTRUCTIS AND USER GUIDE Please read these instructions before installing or using this appliance for the

More information

PERFECT ORIENTATION ZONE 40 E 40 W GOOD GOOD ORIENTATION ZONE ORIENTATION ZONE

PERFECT ORIENTATION ZONE 40 E 40 W GOOD GOOD ORIENTATION ZONE ORIENTATION ZONE product installation data Roof Location and Pitch For optimum performance the solar collector panels or array of vacuum tubes need to face the equator (facing north for southern hemisphere installations).

More information

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................