INSTALLATION AND OPERATION MANUAL

Size: px
Start display at page:

Download "INSTALLATION AND OPERATION MANUAL"

Transcription

1 INSTALLATION AND OPERATION MANUAL System air conditioners FXMQ50P7VEB9 FXMQP7VEB9 FXMQ80P7VEB9 FXMQ00P7VEB9 FXMQ5P7VEB9

2 A B a b c < a b c 7a 80 7c 0 (0~00) A 7b 7a A 7b 8 9 7c mm ~.5 m 00 mm 0~75 5 A 0~5 mm 5 0

3 CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BEYANI CE - IZJAVA O SKLADNOSTI CE - VASTAVUSDEKLARATSIOON CE - ДЕКЛАРАЦИЯ-ЗА-СЪОТВЕТСТВИЕ CE - IZJAVA-O-USKLAĐENOSTI CE - MEGFELELŐSÉGI-NYILATKOZAT CE - DEKLARACJA-ZGODNOŚCI CE - DECLARAŢIE-DE-CONFORMITATE CE - ERKLÆRING OM-SAMSVAR CE - ILMOITUS-YHDENMUKAISUUDESTA CE - PROHLÁŠENÍ-O-SHODĚ CE - DECLARAÇÃO-DE-CONFORMIDADE СЕ - ЗАЯВЛЕНИЕ-О-СООТВЕТСТВИИ CE - OPFYLDELSESERKLÆRING CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE CE - DECLARACION-DE-CONFORMIDAD CE - DICHIARAZIONE-DI-CONFORMITA CE - H ø H YMMOPºø H CE - DECLARATION-OF-CONFORMITY CE - KONFORMITÄTSERKLÄRUNG CE - DECLARATION-DE-CONFORMITE CE - CONFORMITEITSVERKLARING Daikin Europe N.V. 0 a declares under its sole responsibility that the air conditioning models to which this declaration relates: 7 m deklaruje na własną i wyłączną odpowiedzialność, że modele klimatyzatorów, których dotyczy niniejsza deklaracja: 8 r declară pe proprie răspundere că aparatele de aer condiţionat la care se referă această declaraţie: 9 o z vso odgovornostjo izjavlja, da so modeli klimatskih naprav, na katere se izjava nanaša: 0 x kinnitab oma täielikul vastutusel, et käesoleva deklaratsiooni alla kuuluvad kliimaseadmete mudelid: b декларира на своя отговорност, че моделите климатична инсталация, за които се отнася тази декларация: t visiška savo atsakomybe skelbia, kad oro kondicionavimo prietaisų modeliai, kuriems yra taikoma ši deklaracija: v ar pilnu atbildību apliecina, ka tālāk uzskaitīto modeįu gaisa kondicionētāji, uz kuriem attiecas šī deklarācija: k vyhlasuje na vlastnú zodpovednosť, že tieto klimatizačné modely, na ktoré sa vzťahuje toto vyhlásenie: 5 w tamamen kendi sorumluluğunda olmak üzere bu bildirinin ilgili olduğu klima modellerinin aşağıdaki gibi olduğunu beyan eder: 09 u заявляет, исключительно под свою ответственность, что модели кондиционеров воздуха, к которым относится настоящее заявление: 0 q erklærer under eneansvar, at klimaanlægmodellerne, som denne deklaration vedrører: s deklarerar i egenskap av huvudansvarig, att luftkonditioneringsmodellerna som berörs av denna deklaration innebär att: n erklærer et fullstendig ansvar for at de luftkondisjoneringsmodeller som berøres av denne deklarasjon innebærer at: j ilmoittaa yksinomaan omalla vastuullaan, että tämän ilmoituksen tarkoittamat ilmastointilaitteiden mallit: c prohlašuje ve své plné odpovědnosti, že modely klimatizace, k nimž se toto prohlášení vztahuje: 5 y izjavljuje pod isključivo vlastitom odgovornošću da su modeli klima uređaja na koje se ova izjava odnosi: h teljes felelőssége tudatában kijelenti, hogy a klímaberendezés modellek, melyekre e nyilatkozat vonatkozik: 0 d erklärt auf seine alleinige Verantwortung daß die Modelle der Klimageräte für die diese Erklärung bestimmt ist: 0 f déclare sous sa seule responsabilité que les appareils d'air conditionné visés par la présente déclaration: 0 l verklaart hierbij op eigen exclusieve verantwoordelijkheid dat de airconditioning units waarop deze verklaring betrekking heeft: 05 e declara baja su única responsabilidad que los modelos de aire acondicionado a los cuales hace referencia la declaración: 0 i dichiara sotto sua responsabilità che i condizionatori modello a cui è riferita questa dichiarazione: 07 g ËÏÒÓÂÈ Ì appleôîïâèûùèî ÙË Â ı ÓË fiùè Ù ÌÔÓÙ Ï ÙˆÓ ÎÏÈÌ ÙÈÛÙÈÎÒÓ Û ÛΠÒÓ ÛÙ ÔappleÔ Ó Ê ÚÂÙ È Ë apple ÚÔ Û ÏˆÛË: 08 p declara sob sua exclusiva responsabilidade que os modelos de ar condicionado a que esta declaração se refere: FXMQ50P7VEB9, FXMQP7VEB9, FXMQ80P7VEB9, FXMQ00P7VEB9, FXMQ5P7VEB9, megfelelnek az alábbi szabvány(ok)nak vagy egyéb irányadó dokumentum(ok)nak, ha azokat előírás szerint használják: 7 spełniają wymogi następujących norm i innych dokumentów normalizacyjnych, pod warunkiem że używane są zgodnie z naszymi instrukcjami: 8 sunt în conformitate cu următorul (următoarele) standard(e) sau alt(e) document(e) normativ(e), cu condiţia ca acestea să fie utilizate în conformitate cu instrucţiunile noastre 9 skladni z naslednjimi standardi in drugimi normativi, pod pogojem, da se uporabljajo v skladu z našimi navodili: 0 on vastavuses järgmis(t)e standardi(te)ga või teiste normatiivsete dokumentidega, kui neid kasutatakse vastavalt meie juhenditele: съответстват на следните стандарти или други нормативни документи, при условие, че се използват съгласно нашите инструкции: atitinka žemiau nurodytus standartus ir (arba) kitus norminius dokumentus su sąlyga, kad yra naudojami pagal mūsų nurodymus: tad, ja lietoti atbilstoši ražotāja norādījumiem, atbilst sekojošiem standartiem un citiem normatīviem dokumentiem: sú v zhode s nasledovnou(ými) normou(ami) alebo iným(i) normatívnym(i) dokumentom(ami), za predpokladu, že sa používajú v súlade s našim návodom: 5 ürünün, talimatlarımıza göre kullanılması koşuluyla aşağıdaki standartlar ve norm belirten belgelerle uyumludur: 08 estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s) documento(s) normativo(s), desde que estes sejam utilizados de acordo com as nossas instruções: 09 соответствуют следующим стандартам или другим нормативным документам, при условии их использования согласно нашим инструкциям: 0 overholder følgende standard(er) eller andet/andre retningsgivende dokument(er), forudsat at disse anvendes i henhold til vore instrukser: respektive utrustning är utförd i överensstämmelse med och följer följande standard(er) eller andra normgivande dokument, under förutsättning att användning sker i överensstämmelse med våra instruktioner: respektive utstyr er i overensstemmelse med følgende standard(er) eller andre normgivende dokument(er), under forutssetning av at disse brukes i henhold til våre instrukser: vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien vaatimuksia edellyttäen, että niitä käytetään ohjeidemme mukaisesti: za předpokladu, že jsou využívány v souladu s našimi pokyny, odpovídají následujícím normám nebo normativním dokumentům: 5 u skladu sa slijedećim standardom(ima) ili drugim normativnim dokumentom(ima), uz uvjet da se oni koriste u skladu s našim uputama: 0 are in conformity with the following standard(s) or other normative document(s), provided that these are used in accordance with our instructions: 0 der/den folgenden Norm(en) oder einem anderen Normdokument oder -dokumenten entspricht/entsprechen, unter der Voraussetzung, daß sie gemäß unseren Anweisungen eingesetzt werden: 0 sont conformes à la/aux norme(s) ou autre(s) document(s) normatif(s), pour autant qu'ils soient utilisés conformément à nos instructions: 0 conform de volgende norm(en) of één of meer andere bindende documenten zijn, op voorwaarde dat ze worden gebruikt overeenkomstig onze instructies: 05 están en conformidad con la(s) siguiente(s) norma(s) u otro(s) documento(s) normativo(s), siempre que sean utilizados de acuerdo con nuestras instrucciones: 0 sono conformi al(i) seguente(i) standard(s) o altro(i) documento(i) a carattere normativo, a patto che vengano usati in conformità alle nostre istruzioni: 07 Â Ó È Û ÌÊˆÓ Ì ÙÔ( ) ÎfiÏÔ ıô( ) appleúfiù appleô( ) ÏÏÔ ÁÁÚ ÊÔ( ) Î ÓÔÓÈÛÌÒÓ, applefi ÙËÓ appleúô applefiıâûë fiùè ÚËÛÈÌÔappleÔÈÔ ÓÙ È Û ÌÊˆÓ Ì ÙÈ Ô ËÁ Â Ì : EN05--0, 9 Direktive z vsemi spremembami. 0 Direktiivid koos muudatustega. Директиви, с техните изменения. Direktyvose su papildymais. Direktīvās un to papildinājumos. Smernice, v platnom znení. 5 Değiştirilmiş halleriyle Yönetmelikler. 0 Direktiver, med senere ændringer. Direktiv, med företagna ändringar. Direktiver, med foretatte endringer. Direktiivejä, sellaisina kuin ne ovat muutettuina. v platném znění. 5 Smjernice, kako je izmijenjeno. irányelv(ek) és módosításaik rendelkezéseit. 7 z późniejszymi poprawkami. 8 Directivelor, cu amendamentele respective. 0 Directives, as amended. 0 Direktiven, gemäß Änderung. 0 Directives, telles que modifiées. 0 Richtlijnen, zoals geamendeerd. 05 Directivas, según lo enmendado. 0 Direttive, come da modifica. 07 ËÁÈÒv, fiappleˆ Ô Ó ÙÚÔappleÔappleÔÈËıÂ. 08 Directivas, conforme alteração em. 09 Директив со всеми поправками. ** * Low Voltage 0/5/EU Machinery 00//EC Electromagnetic Compatibility 0/0/EU 9 ob upoštevanju določb: 0 vastavalt nõuetele: следвайки клаузите на: laikantis nuostatų, pateikiamų: ievērojot prasības, kas noteiktas: održiavajúc ustanovenia: 5 bunun koşullarına uygun olarak: 0 under iagttagelse af bestemmelserne i: enligt villkoren i: gitt i henhold til bestemmelsene i: noudattaen määräyksiä: za dodržení ustanovení předpisu: 5 prema odredbama: követi a(z): 7 zgodnie z postanowieniami Dyrektyw: 8 în urma prevederilor: 0 following the provisions of: 0 gemäß den Vorschriften der: 0 conformément aux stipulations des: 0 overeenkomstig de bepalingen van: 05 siguiendo las disposiciones de: 0 secondo le prescrizioni per: 07 Ì ٠ÚËÛË Ùˆv È Ù Íˆv Ùˆv: 08 de acordo com o previsto em: 09 в соответствии с положениями: <A> DAIKIN.TCF.0G/07-0 <B> TÜV (NB85) <C> Забележка * както е изложено в <A> и оценено положително от <B> съгласно Cертификата <C>. Pastaba * kaip nustatyta <A> ir kaip teigiamai nuspręsta <B> pagal Sertifikatą <C>. Piezīmes * kā norādīts <A> un atbilstoši <B> pozitīvajam vērtējumam saskaņā ar sertifikātu <C>. Poznámka * ako bolo uvedené v <A> a pozitívne zistené <B> v súlade s osvedčením <C>. 5 Not * <A> da belirtildiği gibi ve <C> Sertifikasına göre <B> tarafından olumlu olarak değerlendirildiği gibi. Megjegyzés * a(z) <A> alapján, a(z) <B> igazolta a megfelelést, a(z) <C> tanúsítvány szerint. 7 Uwaga * zgodnie z dokumentacją <A>, pozytywną opinią <B> i Świadectwem <C>. 8 Notă * aşa cum este stabilit în <A> şi apreciat pozitiv de <B> în conformitate cu Certificatul <C>. 9 Opomba * kot je določeno v <A> in odobreno s strani <B> v skladu s certifikatom <C>. 0 Märkus * nagu on näidatud dokumendis <A> ja heaks kiidetud <B> järgi vastavalt sertifikaadile <C>. Information * enligt <A> och godkänts av <B> enligt Certifikatet <C>. Merk * som det fremkommer i <A> og gjennom positiv bedømmelse av <B> ifølge Sertifikat <C>. Huom * jotka on esitetty asiakirjassa <A> ja jotka <B> on hyväksynyt Sertifikaatin <C> mukaisesti. Poznámka * jak bylo uvedeno v <A> a pozitivně zjištěno <B> v souladu s osvědčením <C>. 5 Napomena * kako je izloženo u <A> i pozitivno ocijenjeno od strane <B> prema Certifikatu <C>. 0 Nota * delineato nel <A> e giudicato positivamente da <B> secondo il Certificato <C>. 07 ËÌ ˆÛË * fiappleˆ Î ıôú ÂÙ È ÛÙÔ <A> Î È ÎÚ ÓÂÙ È ıâùèî applefi ÙÔ <B> Û ÌÊˆÓ Ì ÙÔ ÈÛÙÔappleÔÈËÙÈÎfi <C>. 08 Nota * tal como estabelecido em <A> e com o parecer positivo de <B> de acordo com o Certificado <C>. 09 Примечание * как указано в <A> и в соответствии с положительным решением <B> согласно Свидетельству <C>. 0 Bemærk * som anført i <A> og positivt vurderet af <B> i henhold til Certifikat <C>. 0 Note * as set out in <A> and judged positively by <B> according to the Certificate <C>. 0 Hinweis * wie in der <A> aufgeführt und von <B> positiv beurteilt gemäß Zertifikat <C>. 0 Remarque * tel que défini dans <A> et évalué positivement par <B> conformément au Certificat <C>. 0 Bemerk * zoals vermeld in <A> en positief beoordeeld door <B> overeenkomstig Certificaat <C>. 05 Nota * como se establece en <A> y es valorado positivamente por <B> de acuerdo con el Certificado <C>. 9 ** Daikin Europe N.V. je pooblaščen za sestavo datoteke s tehnično mapo. 0 ** Daikin Europe N.V. on volitatud koostama tehnilist dokumentatsiooni. ** Daikin Europe N.V. е оторизирана да състави Акта за техническа конструкция. ** Daikin Europe N.V. yra įgaliota sudaryti šį techninės konstrukcijos failą. ** Daikin Europe N.V. ir autorizēts sastādīt tehnisko dokumentāciju. ** Spoločnosť Daikin Europe N.V. je oprávnená vytvoriť súbor technickej konštrukcie. 5 ** Daikin Europe N.V. Teknik Yapı Dosyasını derlemeye yetkilidir. ** Daikin Europe N.V. on valtuutettu laatimaan Teknisen asiakirjan. ** Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce. 5 ** Daikin Europe N.V. je ovlašten za izradu Datoteke o tehničkoj konstrukciji. ** A Daikin Europe N.V. jogosult a műszaki konstrukciós dokumentáció összeállítására. 7 ** Daikin Europe N.V. ma upoważnienie do zbierania i opracowywania dokumentacji konstrukcyjnej. 8 ** Daikin Europe N.V. este autorizat să compileze Dosarul tehnic de construcţie. 07 ** Daikin Europe N.V. Â Ó È ÂÍÔ ÛÈÔ ÔÙËÌ ÓË Ó Û ÓÙ ÍÂÈ ÙÔÓ Δ ÓÈÎfi Ê ÎÂÏÔ Î Ù ÛÎÂ. 08 ** A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico. 09 ** Компания Daikin Europe N.V. уполномочена составить Комплект технической документации. 0 ** Daikin Europe N.V. er autoriseret til at udarbejde de tekniske konstruktionsdata. ** Daikin Europe N.V. är bemyndigade att sammanställa den tekniska konstruktionsfilen. ** Daikin Europe N.V. har tillatelse til å kompilere den Tekniske konstruksjonsfilen. 0 ** Daikin Europe N.V. is authorised to compile the Technical Construction File. 0 ** Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen. 0 ** Daikin Europe N.V. est autorisé à compiler le Dossier de Construction Technique. 0 ** Daikin Europe N.V. is bevoegd om het Technisch Constructiedossier samen te stellen. 05 ** Daikin Europe N.V. está autorizado a compilar el Archivo de Construcción Técnica. 0 ** Daikin Europe N.V. è autorizzata a redigere il File Tecnico di Costruzione. Shigeki Morita Director Ostend, nd of November 0 P88-

4 FXMQ50P7VEB9 FXMQ00P7VEB9 FXMQP7VEB9 FXMQ5P7VEB9 FXMQ80P7VEB9 Installation and operation manual CONTENTS Page BEFORE INSTALLATION Before installation... Important information regarding the refrigerant used... Selecting installation site... Preparations before installation... Indoor unit installation... Refrigerant piping work... Drain piping work... 5 Electric wiring work... Wiring example and how to set the remote controller... 7 Wiring example... 8 Field setting... 8 Installation of the decoration panel... 0 Test operation... 0 Maintenance... 0 Disposal requirements... Wiring diagram... READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL. IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE AND INFORMATION. The English text is the original instruction. Other languages are translations of the original instructions. Installation must be done by a licensed technician. The choice of materials and installation must comply with the applicable national and international regulations. Leave the unit inside its packaging until you reach the installation site. Where unpacking is unavoidable, use a sling of soft material or protective plates together with a rope when lifting, this to avoid damage or scratches to the unit. Refer to the installation manual of the outdoor unit for items not described in this manual. Caution concerning refrigerant series R0A: The connectable outdoor units must be designed exclusively for R0A. Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts. Precautions Do not install or operate the unit in rooms mentioned below. - Places with mineral oil, or filled with oil vapour or spray like in kitchens. (Plastic parts may deteriorate.) - Where corrosive gas like sulphurous gas exists. (Copper tubing and brazed spots may corrode.) - Where volatile flammable gas like thinner or gasoline is used. - Where machines generating electromagnetic waves exist. (Control system may malfunction.) - Where the air contains high levels of salt such as air near the ocean and where voltage fluctuates a lot (e.g. in factories). Also in vehicles or vessels. Do not install accessories on the casing directly. Drilling holes in the casing may damage electrical wires and consequently cause fire. This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Accessories Check if the following accessories are included with your unit. Metal clamp piece Drain hose piece Washer for hanging bracket 8 pieces Insulation for fitting Medium sealing pad pieces Large sealing pad piece for gas pipe piece Other: installation and operation manual for liquid pipe piece Screws for duct flanges set pieces Screws for fixing panels are attached to the air inlet panel. FXMQ50-5P7VEB9 P855-.0

5 Optional accessories There are two types of remote controllers: wired and wireless. Select a remote controller according to customer request and install in an appropriate place. Refer to catalogues and technical literature for selecting a suitable remote controller. When installing bottom suction: air inlet panel and canvas connection for the air inlet panel. For the following items, take special care during construction and check after installation is finished Tick when checked Is the indoor unit fixed firmly? The unit may drop, vibrate or make noise. Is the gas leak test finished? It may result in insufficient cooling or heating. Is the unit fully insulated and checked for air leaks? Condensate water may drip. Does drainage flow smoothly? Condensate water may drip. Does the power supply voltage correspond to that shown on the name plate? The unit may malfunction or components may burn out. Are wiring and piping correct? The unit may malfunction or components may burn out. Is the unit safely grounded? Dangerous at electric leakage. Is the wiring size according to specifications? The unit may malfunction or components may burn out. Is nothing blocking the air outlet or inlet of either the indoor or outdoor units? It may result in insufficient cooling or heating. Are refrigerant piping length and additional refrigerant charge noted down? The refrigerant charge in the system might not be clear. Are the air filters fixed properly (when installing with rear duct)? Maintenance of the air filters can be impossible. Is the external static pressure set? It may result in insufficient cooling or heating. Notes to the installer Read this manual carefully to ensure correct installation. Be sure to instruct the customer how to properly operate the system and show him/her the enclosed operation manual. Explain to the customer what system is installed on the site. Be sure to fill out the appropriate installation specifications in the chapter "What to do before operation" of the outdoor unit operation manual. SELECTING INSTALLATION SITE (See figure and figure ) Select an installation site where the following conditions are fulfilled and that meets your customer's approval. - Where optimum air distribution can be ensured. - Where nothing blocks air passage. - Where condensate water can be properly drained. - Where the false ceiling is not noticeably on an incline. - Where sufficient clearance for maintenance and service can be ensured. - Where there is no risk of flammable gas leaking. - The equipment is not intended for use in a potentially explosive atmosphere. - Where piping between indoor and outdoor units is possible within the allowable limit. (Refer to the installation manual of the outdoor unit.) - Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least meter away from televisions and radios. This is to prevent image interference and noise in those electrical appliances. (Noise may be generated depending on the conditions under which the electric wave is generated, even if meter is kept.) - When installing the wireless remote controller kit, the distance between wireless remote controller and indoor unit might be shorter if there are fluorescent lights who are electrically started in the room. The indoor unit must be installed as far as possible away from fluorescent lights. - Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned. Ensure that a protective guard is installed on air suction and air outlet side to prevent that the fan blades or heat exchanger be touched. The protection must comply with relevant European and national regulations. Use suspension bolts for installation. Check whether the ceiling is strong enough to support the weight of the indoor unit. If there is a risk, reinforce the ceiling before installing the unit. Service space Drain pipe Power supply wiring port Transmission wiring port 5 Maintenance drain outlet Gas pipe 7 Liquid pipe IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases. Refrigerant type: R0A GWP () value: () GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information. FXMQ50-5P7VEB9 P855-.0

6 PREPARATIONS BEFORE INSTALLATION Relation of ceiling opening to unit and suspension bolt position. (See figure 5) Model A (mm) B (mm) 0~ ~ Indoor unit Pipe Suspension bolt pitch (x) Suspension bolt pitch distance For installation, choose one of the possibilities as listed further. Standard rear suction (See figure a) Ceiling surface Ceiling opening Service access panel (optional accessory) Air filter 5 Air inlet duct Duct service opening 7 Interchangeable plate Installation with rear duct and duct service opening (See figure b) Installation with rear duct, no duct service opening (See figure c) NOTE Before installation of the unit (in case of installation with duct, but no duct service opening): modify the position of the air filters. Remove the air filter(s) at the outside of the unit Remove the interchangeable plate Install the air filter(s) from the inside of the unit Reinstall the interchangeable plate Mounting the air inlet panel with a canvas connection (See figure 7a) Mounting the air inlet panel directly (See figure 7b) Bottom suction (See figure 7c) NOTE NOTE Ceiling surface Ceiling opening Air inlet panel (Optional accessory) Indoor unit (Back side) 5 Canvas connection for air inlet panel (Optional accessory) Model The fan speed for this indoor unit is preset to provide standard external static pressure. Install the suspension bolts. (Use M0 size bolt for the suspension bolt.) Use anchors for existing ceilings, and a sunken insert, sunken anchors or other field supplied parts for new ceilings to reinforce the ceiling in order to bear the weight of the unit. Installation example (See figure ) NOTE A (mm) 0~ ~ The unit can be used with bottom suction by replacing the interchangeable plate by the air filter holding plate. Air filter holding plate with air filter(s) Interchangeable plate For other installation than standard installation, contact your Daikin dealer for details. Anchor Ceiling slab Long nut or turn-buckle Suspension bolt 5 Indoor unit All the above parts are field supplied. NOTE When installing an air inlet duct, select fixing screws that shall stick out maximum 5 mm at the inside of the flange to protect the air filter from damage during maintenance of the filter. Air inlet duct Inside of the flange Fixing screw 5 mm FXMQ50-5P7VEB9 P855-.0

7 INDOOR UNIT INSTALLATION When installing optional accessories (except for the air inlet panel), read also the installation manual of the optional accessories. Depending on the field conditions, it may be easier to install optional accessories before the indoor unit is installed. Install the indoor unit temporarily. - Attach the hanger bracket to the suspension bolt. Be sure to fix it securely by using a nut and washer from the upper and lower sides of the hanger bracket. (See figure ) Nut (field supply) Washer for hanger bracket (supplied with the unit) Tighten (double nut) Check if the unit is horizontally levelled. - Do not install the unit tilted. The indoor unit is equipped with a built-in drain pump and float switch. (If the unit is tilted against condensate flow, the float switch may malfunction and cause water to drip.) - Check if the unit is levelled at all four corners with a water level or a water-filled vinyl tube as shown in figure 9. Water level Vinyl tube Tighten the upper nut. Refer to Table for the dimensions of flare nut spaces and the appropriate tightening torque. (Overtightening may damage the flare and cause leaks.) Table Pipe gauge (mm) Tightening torque (N m) Flare dimension A (mm) Ø. 5~7 8.7~9. Ø9.5 ~9.8~. Ø.7 50~0.~. Ø5.9 ~75 9.~9.7 Flare shape When connecting the flare nut, coat the flare inner surface with ether oil or ester oil and initially tighten or turns by hand before tightening firmly. If the refrigerant gas leaks during the work, ventilate the area. A toxic gas is emitted by the refrigerant gas being exposed to a fire. Make sure there is no refrigerant gas leak. A toxic gas may be released by the refrigerant gas leaking indoor and being exposed to flames from an area heater, cooking stove, etc. Finally, insulate as shown in the figures below. Piping insulation procedure 90 ± A 5 ± R=0.~0.8 REFRIGERANT PIPING WORK For refrigerant piping of outdoor unit, refer to the installation manual supplied with the outdoor unit. Gas piping 5 Liquid piping 5 Before rigging tubes, check which type of refrigerant is used. All field piping must be provided by a licensed refrigeration technician and must comply with the relevant local and national codes. A C 7 D B A C B 7 D Use a pipe cutter and flare suitable for the used refrigerant. To prevent dust, moisture or other foreign matter from infiltrating the tube, either pinch the end, or cover it with tape. Use copper alloy seamless pipes (ISO 7). The outdoor unit is charged with refrigerant. To prevent water leakage, execute heat insulation work completely on both sides of the gas and liquid piping. When using a heat pump, the temperature of the gas piping can reach up to approximately 0 C, use insulation which is sufficiently heat resistant. Be sure to use both a spanner and torque wrench together when connecting or disconnecting pipes to/from the unit. Torque wrench Spanner Piping union Flare nut Do not mix anything other than the specified refrigerant, such as air, etc..., inside the refrigerant circuit. Use annealed material only for flare connections. Piping insulation material (field supply) Flare nut connection Insulation for fitting (delivered with the unit) Piping insulation material (main unit) 5 Main unit Clamp (field supply) 7 Medium sealing pad for gas piping (delivered with the unit) Medium sealing pad for liquid piping (delivered with the unit) A Turn seams up B Attach to base C Tighten the part other than the piping insulation material D Wrap over from the base of the unit to the top of the flare nut connection For local insulation, be sure to insulate local piping all the way into the pipe connections inside the unit. Exposed piping may cause condensation or may cause burns when touched. FXMQ50-5P7VEB9 P855-.0

8 Cautions for brazing Be sure to carry out a nitrogen blow when brazing. Brazing without carrying out nitrogen replacement or releasing nitrogen into the piping will create large quantities of oxidized film on the inside of the pipes, adversely affecting valves and compressors in the refrigerating system and preventing normal operation. When brazing while inserting nitrogen into the piping, nitrogen must be set to 0.0 MPa with a pressure-reducing valve (=just enough so that it can be felt on the skin). 5 - Wrap the supplied large sealing pad over the metal clamp and drain hose to insulate and fix it with clamps. - Insulate the complete drain piping inside the building (field supply). - If the drain hose cannot be sufficiently set on a slope, fit the hose with drain raising piping (field supply). How to perform drain piping (See figure 0) Ceiling slab Hanger bracket Adjustable range Drain raising pipe 5 Drain hose (supplied with the unit) Clamp metal (supplied with the unit) Refrigerant piping Part to be brazed Taping Hands valve 5 Pressure-reducing valve Nitrogen Connect the drain hose to the drain raising pipes, and insulate them. Connect the drain hose to the drain outlet on the indoor unit, and tighten it with the clamp. Installation A (mm) Rear suction installation When canvas duct is installed When air inlet panel is directly installed DRAIN PIPING WORK Rig the drain piping as shown in the figure and take measures against condensation. Improperly rigged piping could lead to leaks and eventually wet furniture and belongings. Hanging bar -.5 m Install the drain pipes. - Keep piping as short as possible and slope it downwards at a gradient of at least /00 so that air may not remain trapped inside the pipe. - Keep pipe size equal to or greater than that of the connecting pipe (vinyl pipe of 5 mm nominal diameter and mm outer diameter). - Push the supplied drain hose as far as possible over the drain socket. - Tighten the metal clamp until the screw head is less than mm from the metal clamp part as indicated in the illustration. 5 A A' mm 5 A-A' Precautions - Install the drain raising pipes at a height of less than 5 mm. - Install the drain raising pipes at a right angle to the indoor unit and no more than 00 mm from the unit. - To prevent air bubbles, install the drain hose level or slightly tilted up ( 75 mm). NOTE Testing of drain piping The incline of attached drain hose should be 75 mm or less so that the drain socket does not have to withstand additional force. To ensure a downward slope of :00, install hanging bars every to.5 m. When unifying multiple drain pipes, install the pipes as shown in figure. Select converging drain pipes whose gauge is suitable for the operating capacity of the unit. T-joint converging drain pipes After piping work is finished, check if drainage flows smoothly. Add approximately l of water gradually through the air discharge outlet. Check for water leaks. Method of adding water. See figure 8. Water inlet Portable pump Water inlet cover Bucket (adding water through water inlet) 5 Drain outlet for maintenance (with rubber drain plug) Refrigerant pipes Drain socket (attached to the unit) Drain hose (supplied with the unit) Metal clamp (supplied with the unit) Drain piping (field supply) 5 Large sealing pad (supplied with the unit) 5 FXMQ50-5P7VEB9 P855-.0

9 Caution for drain socket Do not remove the drain pipe plug. Water might leak out. The drain outlet is only used to discharge water if the drain pump is not used or before maintenance. Gently put in and out the drain plug. Excessive force may deform the drain socket of the drain pan. Pulling out the plug Drain plug Do not wiggle the plug up and down Pushing in the plug Drain plug Crosshead screwdriver Set the plug and push it by using a crosshead screwdriver First perform electric wiring work as instructed in "Electric wiring work" on page and how to set the remote controller as explained in "Wiring example and how to set the remote controller" on page 7. When electric wiring work is finished Check drainage flow during COOL running, explained in "Test operation" on page 0. When electric wiring work is not finished Remove the switch box cover and connect the single-phase power supply and the remote controller to the terminals. (Refer to "Electric wiring work" on page for switch box attachment/detachment.) (Refer to figure and figure ) Switch box cover Transmission wiring port Power supply wiring port Wiring diagram 5 Switch box Plastic clamp 7 Remote controller wiring 8 Terminal board for unit transmission wiring 9 Power supply wiring 0 Indoor PC board Power supply terminal board Transmission wiring between units Indoor PC board Indoor PC board (only for 50~5 units) ELECTRIC WIRING WORK General instructions All field supplied parts and materials and electric works must conform to local codes. Use copper wire only. Follow the "Wiring diagram" attached to the unit body to wire the outdoor unit, indoor units and the remote controller. For details on hooking up the remote controller, refer to the "Installation manual of the remote controller". All wiring must be performed by an authorized electrician. Attach the earth leakage circuit breaker and fuse to the power supply line. A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated in the fixed wiring in accordance with relevant local and national legislation. Note that the operation will restart automatically if the main power supply is turned off and then turned back on again. This system consists of multiple indoor units. Mark each indoor unit as unit A, unit B..., and be sure the terminal block wiring to the outdoor unit and BS unit are properly matched. If wiring and piping between the outdoor unit and an indoor unit are mismatched, the system may cause a malfunction. Be sure to ground the air conditioner. Do not connect the ground wire to: - gas pipes: might cause explosions or fire if gas leaks. - telephone ground wires or lightning rods: might cause abnormally high electric potential in the ground during lightning storms. - plumbing pipes: no grounding effect if hard vinyl piping is used. Make sure electrical wires are stripped equally. Electrical characteristics Model Hz Volts Voltage range 0 MCA: Min. circuit Amps (A) MFA: Max. Fuse Amps (A) Power supply MCA /0 0-0/0 ±0% NOTE 0. MFA A For details, refer to "Electrical data" in the technical data book. Next, press the inspection/test operation button on the remote controller. The unit will engage the test operation mode. Press the operation mode selector button until selecting fan operation. Then, press the on/off button. The indoor unit fan and drain pump will start up. Check that the water has drained from the unit. Press to go back to the first mode. FXMQ50-5P7VEB9 P855-.0

10 Specifications for field supplied fuses and wire - When connecting wires of the same gauge, connect them according to the figure. Power supply wiring Model Field fuses Wire Size 0~5 A H05VV-UG Local codes Model Wire Size 0~5 Sheathed wire () mm NOTE For details, refer to "Wiring example" on page 8. Allowable length of transmission wiring between indoor and outdoor units, and between the indoor unit and the remote controller is as follows:. Outdoor unit - indoor unit: max. 000 m (total wiring length: 000 m). Indoor unit - remote controller: max 500 m WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER How to connect wiring Remove the switch box cover as shown in figure, and make the connections. Switch box cover Transmission wiring port Power supply wiring port Wiring diagram 5 Switch box PRECAUTIONS Observe the notes mentioned below when wiring to the power supply terminal board. - Use a round crimp-style terminal for insulation sleeve for connection to the terminal block for wiring the units. When none are available, follow the instructions below. Round crimp-style terminal Attach insulation sleeve Wiring - Do not connect wires of different gauge to the same power supply terminal. (Looseness in the connection may cause overheating.) Use the specified electric wire. Connect the wire securely to the terminal. Lock the wire down without applying excessive force to the terminal. Use torques according to the table below. Tightening torque (N m) Terminal block for unit transmission and remote controller 0.9 Terminal block for power supply. - When attaching the control box lid, make sure not to pinch any wires. - After all wiring connections are done, fill in any gaps in the casing wiring holes with putty or insulation material (field supply) thus to prevent small animals or dirt from entering the unit from outside and causing short circuits in the control box. Keep total current of crossover wiring between indoor units less than A. Branch the line outside the terminal board of the unit in accordance with electrical equipment standards, when using two power wiring of a gauge greater than mm (Ø.). The branch must be sheathed in order to provide an equal or greater degree of insulation as power supply wiring itself. Do not connect wires of different gauge to the same grounding terminal. Looseness in the connection may deteriorate the protection. Remote controller cords and wires connecting the units should be located at least 50 mm away from power supply wiring. Not following this guideline may result in malfunction due to electrical noise. 5 For the remote controller wiring, refer to the "Installation manual of the remote controller" supplied with the remote controller. Never connect the power supply wiring to the terminal board for transmission wiring. This mistake could damage the entire system. 7 Use only specified wires and tightly connect wires to the terminals. Be careful that wires do not place external stress on the terminals. Keep wiring in neat order so that they do not obstruct other equipment such as popping open the switch box cover. Make sure the cover closes tight. Incomplete connections could result in overheating, and in the worse case, electric shock or fire. 7 FXMQ50-5P7VEB9 P855-.0

11 WIRING EXAMPLE Fit the power supply wiring of each unit with a switch and fuse as shown in figure. Power supply Main switch Power supply wiring Transmission wiring 5 Switch Fuse 7 BS unit REYQ only 8 Indoor unit 9 Remote controller Complete system example ( systems) When using remote controller for indoor unit (Normal operation) (See figure 5) For group control or use with remote controllers (See figure 7) When including BS unit (See figure ) NOTE Outdoor unit Indoor unit Remote controller (optional accessories) Most downstream indoor unit 5 For use with remote controllers BS unit PRECAUTIONS It is not necessary to designate an indoor unit address when using group control. The address is automatically set when the power is activated. A single switch can be used to supply power to units on the same system. However, branch switches and branch circuit breakers must be selected carefully. For a group control remote controller, choose the remote controller that suits the indoor unit which has the most functions. Do not ground the equipment on gas pipes, water pipes, lightning rods or crossground with telephones. Improper grounding could result in electric shock. FIELD SETTING Field setting must be made on the remote controller in function of the installation condition. Setting can be made by changing the "Mode number", "First code No." and "Second code No.". For setting and operation, refer to the "Field settings" in the installation manual of the remote controller. Summary of field settings Mode No. (Note ) 0 (0) () 5 (5) Note : First code No. 0 Description of setting Filter contamination - Heavy/Light = Setting to define time between filter cleaning display indications. (When contamination is high, setting can be changed to half the time inbetween filter cleaning display indications.) Ultra-longlife filter Long-life filter Standard filter Thermostat sensor selection 0 Light Second code No. (Note ) ±0,000 hrs. Heavy ±5,000 hrs. ±,500 hrs. ±,50 hrs. ±00 hrs. ±00 hrs. Use both the unit sensor (or remote sensor if installed) AND the remote controller sensor. (See note 5+) Use unit sensor only (or remote sensor if installed). (See note 5+) Use remote controller sensor only. (See note 5+) Setting for display of time between filter cleaning display Display Do not display indications Thermostat sensor in group control Output signal X-X of the optional KRPB PCB kit ON/OFF input from outside (T/T input) = Setting when forced ON/OFF is to be operated from outside. Fan setting during thermostat OFF at heating operation Differential automatic changeover Use unit sensor only (or remote sensor if installed). (See note ) Thermostat-on + compressor run Forced OFF LL Use both the unit senor (or remote sensor if installed) AND the remote controller sensor. (See note +5+) Operation ON/OFF operation Set speed 0 C C C OFF (See note ) 5 Auto-restart after power failure Disabled Enabled 9 Fixed cool/heat master Disabled Enabled Drain pump operation + humidifier interlock Equipped Not equipped Malfunction C (See note 7) Setting is carried out in the group mode, however, if the mode number inside parentheses is selected, indoor units can also be set individually. Note : Factory settings of the Second code No. are marked in grey backgrounds. Note : Only use in combination with optional remote sensor or when setting 0--0 is used. Note : If group control is selected and remote control sensor is to be used, then set 0--0 & Note 5 : If setting or 0--0 or 0--0 are set at the same time, then setting 0--0, 0--0 or 0--0 have priority. Note : Note 7 : If setting or 0--0 or 0--0 are set at the same time, then setting for group connection, 0--0 has priority and for individual connection, 0--0, 0--0 or 0--0 have priority. More settings for Differential automatic change over temperatures are: Second code No. 05 C 0 5 C 07 C 08 7 C FXMQ50-5P7VEB9 P

12 External static pressure settings Settings for external static pressure can be achieved in ways: Using the airflow automatic adjustment function Airflow automatic adjustment is the volume of blow-off air that has been automatically adjusted to the rated quantity. Make sure the test run is done with a dry coil. If the coil is not dry, run the unit for hours with fan only to dry the coil. Check if the power supply wiring to the air conditioning unit is completed along with the duct installation. If a closing damper is installed in the air conditioning unit, make sure that it is open. Also check if the air filter is properly attached into the air passage on the air suction side of the air conditioning unit. If there is more than one air inlet and outlet, adjust the dampers so that the airflow rate of each air inlet and outlet is conform with the designed airflow rate. Make sure the air conditioning unit is in fan operation mode. Press and set the airflow adjustment button on the remote controller to change the airflow rate to H or L. Setting the airflow automatic adjustment settings. When the air conditioning unit is running in fan operation mode perform the next steps: - stop the air conditioning unit, - go to field setting mode, - select mode No. (or in case of group setting), - set the first code No. to "7", - set the second code No. to "0". Return to normal operating mode after setting these settings and press the ON/OFF operation button. The operation lamp will light up and the air conditioning unit will start the fan operation for airflow automatic adjustment. Do not adjust the dampers during fan operation for airflow automatic adjustment. After to 8 minutes, the air conditioning unit stops operating automatically when the fan operation for airflow automatic adjustment has been carried out, the operation lamp will be off. Mode No. First code No. () 7 Second code No. Setting content 0 Airflow adjustment is OFF 0 Completion of airflow adjustment 0 Start of airflow adjustment 5 When the air conditioning unit has stopped, check on an indoor unit if the second code No. of mode No. is set to "0". If the air conditioning unit does not stop operating or the second code No. is not "0", repeat step. If the outdoor unit is not turned on, the display on the remote controller will show "U" or "UH" (refer to "Test operation" on page 0). However, you can continue setting this function because these messages are only applicable to outdoor units. After setting this function, be sure to turn on the outdoor unit before performing the test operation on the outdoor unit. If any other error display occurs on the display of the remote controller, refer to "Test operation" on page 0 and the operation manual of the outdoor unit. Check the defective point. Using the remote controller Check on an indoor unit if the second code of mode No. is set to "0" (= factory setting). Change the second code according to the external static pressure of the duct to be connected as shown in table. Table If there is no change after airflow adjustment in the ventilation paths, be sure to perform setting the automatic airflow adjustment again. Contact your dealer if there is no change after performing airflow adjustment in the ventilation paths, after performing the test operation of the outdoor unit or when the air conditioning unit is moved to another location. If booster fans, an outdoor air processing unit or HRV via duct are used, do not use automatic airflow adjustment control with a remote controller. If the ventilation paths have been changed, perform the setting of the airflow automatic adjustment again as described above from step onwards. NOTE The second code No. is set to "0 (FXMQ0~) / 07 (FXMQ0~5)" by default. Mode No. () First code No. Second code No. External static pressure (Pa) Model Control by Remote Controllers (Controlling indoor unit by remote controllers) When using remote controllers, one must be set to "MAIN" and the other to "SUB". MAIN/SUB CHANGEOVER Insert a wedge-head screwdriver into the recess between the upper and lower part of the remote controller and, working from the positions, pry off the upper part. (See figure 8) (The remote controller PC board is attached to the upper part of the remote controller.) Turn the main/sub changeover switch on one of the two remote controller PC boards to "S". (See figure 9) (Leave the switch of the other remote controller set to "M".) Remote controller PC board Factory setting Only one remote controller needs to be changed 9 FXMQ50-5P7VEB9 P855-.0

13 Computerised control (forced off and on/off operation) Wire specifications and how to perform wiring - Connect input from outside to terminals T and T of the terminal board (remote controller to transmission wiring). Wire specification Sheathed vinyl cord or cable ( wire) Gauge mm Length External terminal F T T FORCED OFF Actuation - The following table explains "forced off" and "on/off operations" in response to input A. Forced off Input "on" stops operation Input "off" enables control How to select forced off and on/off operation - Turn the power on and then use the remote controller to select operation. - Set the remote controller to the field set mode. For details, refer to the chapter "How to set in the field", in the remote controller manual. - When in the field set mode, select mode No., then set the first code No. to "". Then set second code (position) No. to "0" for forced off and to "0" for on/off operation. (forced off at factory set.) (See figure 0) Centralized control Input A Second code No. Mode No. First code No. Field set mode Max. 00 m Contact that can ensure the minimum applicable load of 5 V DC, 0 ma on/off operation input off on: turns on the unit (impossible by remote controllers) input on off: turns off the unit by remote controller For centralized control, it is necessary to designate the group No. For details, refer to the manual of each optional controller for centralized control. INSTALLATION OF THE DECORATION PANEL Refer to the installation manual attached to the decoration panel. After installing the decoration panel, ensure that there is no space between the unit body and decoration panel. TEST OPERATION Refer to the installation manual of the outdoor unit. The operation lamp of the remote controller will flash when an error occurs. Check the error code on the liquid crystal display to identify the trouble. Error code A8 C C U Meaning If any of the items in following table are displayed on the remote controller, there may be a problem with the wiring or power, so check the wiring again. Error code U or UH no display MAINTENANCE Error in power supply to indoor unit Transmission error between fan driver PCB and controller PCB of the indoor unit Improper combination of fan driver PCB of the indoor unit or setting failure in control PCB type Test operation of the indoor unit has not been finished Meaning There is a short circuit at the forced off terminals (T, T) - The power on the outdoor unit is off - The outdoor unit has not been wired for power supply - Incorrect transmission of forced off wiring - The power on the indoor unit is off - The indoor unit has not been wired for power supply - Incorrect transmission wiring, forced off wiring or remote controller wiring Caution Only a qualified service person is allowed to perform maintenance. Before obtaining access to terminal devices, all power supply circuits must be interrupted. Do not use water or air of 50 C or higher for cleaning air filters and outside panels. When cleaning the heat exchanger, be sure to remove the switchbox, fan motor, auxiliary electric heater and drain pump. Water or detergent may deteriorate the insulation of electronic components and result in burnout of these components. If the main power supply is turned off during operation, operation will restart automatically after the power turns back on again. How to clean the air filter Clean the air filter when the display shows " " (TIME TO CLEAN AIR FILTER). Increase the frequency of cleaning if the unit is installed in a room where the air is extremely contaminated. If the dirt becomes impossible to clean, change the air filter. (Air filter for exchange is optional.) Open the suction grille. (Only for bottom suction.) Slide both knobs simultaneously as shown and then pull them downward. FXMQ50-5P7VEB9 P

14 If chains are present, unhook the chains. 5 Shut the air inlet grille. (Only for bottom suction.) Refer to item no.. After turning on the power, press FILTER SIGN RESET button. The "TIME TO CLEAN AIR FILTER" display is turned off. How to clean air outlet and outside panels Remove the air filters. Remove the air filters by pulling their cloth upward (rear suction) or backward (bottom suction). Clean with soft cloth. When it is difficult to remove stains, use water of neutral detergent. Clean the air inlet grille when it is shut. NOTE Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide. It may cause discolouring or warping. Do not let the indoor unit get wet. It may cause an electric shock or a fire. rear suction bottom suction Clean the air filter. Use vacuum cleaner (A) or wash the air filter with water (B). (A) Using a vacuum cleaner (B) Washing with water Start up after a long stop Confirm the following: Check that the air inlet and outlet are not blocked. Remove any obstacle. Check if the earth is connected. Clean the air filter and outside panels. After cleaning the air filter, make sure to attach it. Turn on the main power supply switch. The control panel display lights when the power is turned on. To protect the unit, turn on the main power switch at least hours before operation. What to do when stopping the system for a long period When the air filter is very dirty, use soft brush and neutral detergent. Remove water and dry in the shade. Turn on FAN OPERATION for half a day and dry the unit. Refer to the operation manual of the outdoor unit. Cut off the power supply. When the main power switch is turned on, some wattage is being consumed even if the system is not operating. The remote controller display is turned off when the main power switch is turned off. Fix the air filter. rear suction DISPOSAL REQUIREMENTS Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in accordance with relevant local and national legislation. bottom suction Align the two hanger brackets and push the two clips in their place (pull the cloth if necessary). Confirm that four hangers are fixed. FXMQ50-5P7VEB9 P855-.0

15 WIRING DIAGRAM : FIELD WIRING BLK : BLACK ORG : ORANGE : CONNECTOR BLU : BLUE PNK : PINK : WIRE CLAMP BRN : BROWN RED : RED : PROTECTIVE EARTH (SCREW) GRN : GREEN WHT : WHITE L : LIVE GRY : GREY YLW : YELLOW N : NEUTRAL AP... PRINTED CIRCUIT BOARD AP... PRINTED CIRCUIT BOARD (FAN) AP... PRINTED CIRCUIT BOARD (CAPACITOR) (only for 50~5 units) C,C,C... CAPACITOR FU... FUSE (T,.5 A, 50 V) FU... FUSE (T, 5 A, 50 V) FU,FU... FUSE (T,. A, 50 V) HAP... LIGHT EMITTING DIODE (SERVICE MONITOR - GREEN) KPR,KR... MAGNETIC RELAY LR... REACTOR MF... MOTOR (FAN) MP... MOTOR (DRAIN PUMP) PS... SWITCHING POWER SUPPLY QDI... EARTH LEAK DETECTOR R... RESISTOR (CURRENT LIMITING) R... CURRENT SENSING DEVICE R,R... RESISTOR (ELECTRIC DISCHARGE) RT... THERMISTOR (SUCTION AIR) RT... THERMISTOR (LIQUID) RT... THERMISTOR (GAS) R5T... THERMISTOR NTC (CURRENT LIMITING) SL... FLOAT SWITCH VR... DIODE BRIDGE VR... POWER MODULE XM... TERMINAL STRIP (POWER SUPPLY) XM... TERMINAL STRIP (CONTROL) YE... ELECTRONIC EXPANSION VALVE ZC,ZC... NOISE FILTER (FERRITE CORE) ZF... NOISE FILTER CONNECTOR OPTIONAL ACCESSORY X8A... CONNECTOR (POWER SUPPLY FOR WIRING) XA... CONNECTOR (FOR WIRING) X5A... CONNECTOR (ADAPTOR) X8A... CONNECTOR (FOR WIRING) WIRED REMOTE CONTROLLER RT... THERMISTOR (AIR) SS... SELECTOR SWITCH (MAIN/SUB) WIRED REMOTE CONTROLLER : (OPTIONAL ACCESSORY) : SWITCH BOX (INDOOR) : TRANSMISSION WIRING : CENTRAL REMOTE CONTROLLER : INPUT FROM OUTSIDE : NOTE. USE COPPER CONDUCTORS ONLY.. WHEN USING THE CENTRAL REMOTE CONTROLLER, SEE MANUAL FOR CONNECTION TO THE UNIT.. WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED "OFF" OR "ON/OFF" CONTROL OPERATION CAN BE SELECTED BY THE REMOTE CONTROLLER. SEE INSTALLATION MANUAL FOR MORE DETAILS. FXMQ50-5P7VEB9 P855-.0

16

17

18

19 5 L N Control box IN/D OUT/D F F F F Control box OUT/D IN/D F F F F L N P P F F T T 5 P P 0 5 Control box IN/D OUT/D F F F F L N L N L N L N L N L N L N L N L N P P F F T T P P F F T T P P F F T T P P F F T T P P P P P P P P L N Control box IN/D OUT/D F F F F 7 L N L N L N L N P P F F T T P P F F T T P P F F T T P P F F T T 8 9 P P 5 P P P P S M S M SETTING 8 9 0

INSTALLATION MANUAL. R-407C split series outdoor units R25GZ7V11 R35GZ7V11 R45GZ7V11 R45GZ7W11

INSTALLATION MANUAL. R-407C split series outdoor units R25GZ7V11 R35GZ7V11 R45GZ7V11 R45GZ7W11 INSTALLATION MANUAL R-407C split series outdoor units R25GZ7V11 R35GZ7V11 R45GZ7V11 R45GZ7W11 CE - DECLARATION-OF-CONFORMITY CE - CONFORMITEITSVERKLARING CE - H ø H YMMOPºø H CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXZQ07M7VJU FXZQ09M7VJU FXZQM7VJU FXZQ8M7VJU 5 6 7 8 9 0 x x 8x x x x x x x x x x x 5.8.8 5 ~ 5 6 7 8 5 59* 59* 59 7.6 ~6.6 00 8 6 7 9 F T T FORCED

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioner FXFQ0MVB FXFQMVB FXFQMVB FXFQ0MVB FXFQ0MVB FXFQMVB FXFQ80MVB FXFQ00MVB FXFQMVB H H 000 00 00 * * 00 00 * * 90 890 80 80 80 90 0-00 8 80 80 80~90

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXFQ0AVEB FXFQAVEB FXFQAVEB FXFQ0AVEB FXFQ0AVEB FXFQAVEB FXFQ80AVEB FXFQ00AVEB FXFQAVEB CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXFQ0P9VEB FXFQP9VEB FXFQP9VEB FXFQ0P9VEB FXFQ0P9VEB FXFQP9VEB FXFQ80P9VEB FXFQ00P9VEB FXFQP9VEB 00 00 * * 90 0-00 7 00 mm ~. m 8 0~7 7 7 80 7

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL FMDQ0B7VEB FMDQ60B7VEB FMDQ7B7VEB FMDQ00B7VEB FMDQB7VEB 76 00 A B 60 700 6a 6b 6c < 00 680 6 680 7 680 6a 6b 6c 7a 80 7c 60 (60~00) 60 A 7b 7a 80 0 60 A 7b 8 9 6 7c 0

More information

INSTALLATION MANUAL. Packaged water-cooled water chillers EWWP014KAW1N EWWP022KAW1N EWWP028KAW1N EWWP035KAW1N EWWP045KAW1N EWWP055KAW1N EWWP065KAW1N

INSTALLATION MANUAL. Packaged water-cooled water chillers EWWP014KAW1N EWWP022KAW1N EWWP028KAW1N EWWP035KAW1N EWWP045KAW1N EWWP055KAW1N EWWP065KAW1N INSTALLATION MANUAL EWWP014KAW1N EWWP022KAW1N EWWP028KAW1N EWWP035KAW1N EWWP045KAW1N EWWP055KAW1N EWWP065KAW1N CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ

More information

INSTALLATION MANUAL R410A SPLIT SERIES MODELS FTXN25LV1B FTXN35LV1B RXN25LV1B RXN35LV1B RXN50LV1B RXN60LV1B FTXN50LV1B FTXN60LV1B.

INSTALLATION MANUAL R410A SPLIT SERIES MODELS FTXN25LV1B FTXN35LV1B RXN25LV1B RXN35LV1B RXN50LV1B RXN60LV1B FTXN50LV1B FTXN60LV1B. INSTALLATION MANUAL Installation Manual R410A Split Series Manuale d installazione Serie Multiambienti R410A English Italiano R410A SPLIT SERIES Installationsanleitung Split-Baureihe R410A Deutsch Manual

More information

INSTALLATION MANUAL. Packaged water-cooled water chillers EWWP045KAW1M EWWP055KAW1M EWWP065KAW1M ECB2MUAW ECB3MUAW

INSTALLATION MANUAL. Packaged water-cooled water chillers EWWP045KAW1M EWWP055KAW1M EWWP065KAW1M ECB2MUAW ECB3MUAW INSTALLATION MANUAL EWWP045KAWM EWWP055KAWM EWWP065KAWM ECBMUAW ECBMUAW CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ CE - IZJAVA O SKLADNOSTI

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners INSTALLATION MANUAL SYSTEM Inverter Air Conditioners English Español MODELS Ceiling mounted cassette type (Round flow model) FXFQ25PVE(9) FXFQ32PVE(9) FXFQ40PVE(9) FXFQ50PVE(9) FXFQ63PVE(9) FXFQ80PVE(9)

More information

INSTALLATION MANUAL. Split System air conditioners FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB

INSTALLATION MANUAL. Split System air conditioners FCQ35C7VEB FCQ50C7VEB FCQ60C7VEB FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB INSTALLATION MANUAL FCQC7VEB FCQ0C7VEB FCQ0C7VEB FCQ7C7VEB FCQ00C7VEB FCQC7VEB FCQ0C7VEB FCQH7D7VEB FCQH00D7VEB FCQHD7VEB FCQH0D7VEB 00 00 * * 90 0-00 7 00 mm ~. m 8 0~7 7 7 80 7 8 9 00 mm 0~7 mm 9 0 7

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXCQ0M8VB FXCQM8VB FXCQM8VB FXCQ0M8VB FXCQ0M8VB FXCQM8VB FXCQ80M8VB FXCQM8VB H 0 0 00 000 00 80 0 B C 00 0 0 0 A 0 00 00 D 00 8 00 mm ~ m 00 90

More information

INSTALLATION MANUAL. Packaged water-cooled water chillers EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N

INSTALLATION MANUAL. Packaged water-cooled water chillers EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N INSTALLATION MANUAL EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ

More information

INSTALLATION MANUAL. Split System air conditioners AZQS71B2V1B AZQS100A7V1B AZQS125A7V1B AZQS140A7V1B AZQS100A7W1B AZQS125A7W1B AZQS140A7W1B

INSTALLATION MANUAL. Split System air conditioners AZQS71B2V1B AZQS100A7V1B AZQS125A7V1B AZQS140A7V1B AZQS100A7W1B AZQS125A7W1B AZQS140A7W1B INSTLLTION MNUL Split System air conditioners ZQS7BVB ZQS007VB ZQS57VB ZQS407VB ZQS007WB ZQS57WB ZQS407WB B D E L C L D H B B D C E H L B L D E B L C H D H 4 B 6 V-type ~ 50 Hz 0-40 V L W-type N~ 50 Hz

More information

INSTALLATION MANUAL. R32 Split Series. Models RXM42LV1B RXM50LV1B RXJ50LV1B RXM42MV1B RXM50MV1B RXJ50MV1B ARXM50MV1B

INSTALLATION MANUAL. R32 Split Series. Models RXM42LV1B RXM50LV1B RXJ50LV1B RXM42MV1B RXM50MV1B RXJ50MV1B ARXM50MV1B INSTALLATION MANUAL R32 Split Series Installation manual R32 Split series English Installationsanleitung Split-Baureihe R32 Deutsch Models RXM42LV1B RXM50LV1B RXJ50LV1B RXM42MV1B RXM50MV1B RXJ50MV1B ARXM50MV1B

More information

SPLIT SYSTEM Air Conditioners

SPLIT SYSTEM Air Conditioners INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling-mounted Cassette type (Multi flow model) FCQ24MVJU FCQ30MVJU FCQ36MVJU FCQ42MVJU Read these instructions carefully before installation.

More information

INSTALLATION MANUAL Split System air conditioners

INSTALLATION MANUAL Split System air conditioners INSTALLATION MANUAL Split System air conditioners FHA35AVEB(9) FHA50AVEB(9) FHA60AVEB(9) FHA71AVEB(9) FHA100AVEB FHA125AVEB FHA140AVEB CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. English. Deutsch. Français. Nederlands. Español. Italiano.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. English. Deutsch. Français. Nederlands. Español. Italiano. English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Deutsch Portugues Pyccкий Türkçe Eλληνικά Italiano Español Nederlands Français MODELS FTXS35K2V1B FTXS42K2V1B FTXS50K2V1B ATXS35K2V1B

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTLLTION ND OPERTION MNUL System air conditioner FXYSP0K7V FXYSPK7V FXYSPK7V FXYSP0K7V FXYSP0K7V FXYSPK7V FXYSP80K7V FXYSP00K7V FXYSPK7V CE - DECLRTION-OF-CONFORMITY CE - CONFORMITEITSVERKLRING CE -

More information

INSTALLATION MANUAL. R410A Split series FDXS25F2VEB FDXS35F2VEB FDXS50F2VEB FDXS60F2VEB FDXS50F2VEB9

INSTALLATION MANUAL. R410A Split series FDXS25F2VEB FDXS35F2VEB FDXS50F2VEB FDXS60F2VEB FDXS50F2VEB9 INSTALLATION MANUAL R410A Split series FDXS25F2VEB FDXS35F2VEB FDXS50F2VEB FDXS60F2VEB FDXS50F2VEB9 CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI CE

More information

INSTALLATION MANUAL. System air conditioner BSV4Q100P7V1

INSTALLATION MANUAL. System air conditioner BSV4Q100P7V1 INSTALLATION MANUAL System air conditioner CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ CE - IZJAVA O SKLADNOSTI CE - VASTAVUSDEKLARATSIOON CE

More information

SPLIT SYSTEM Air Conditioners. Read these instructions carefully before installation. Keep this manual in a handy place for future reference.

SPLIT SYSTEM Air Conditioners. Read these instructions carefully before installation. Keep this manual in a handy place for future reference. INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling mounted cassette type (Round flow model) FCQ18PAVJU FCQ24PAVJU FCQ30PAVJU FCQ36PAVJU FCQ42PAVJU English Français Español Read these instructions

More information

INSTALLATION MANUAL. R410A Split Series. Models RX50KV1B RX60KV1B RX71KV1B

INSTALLATION MANUAL. R410A Split Series. Models RX50KV1B RX60KV1B RX71KV1B INSTALLATION MANUAL R410A Split Series Models RX50KV1B RX60KV1B RX71KV1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI CE - IZJAVA O SKLADNOSTI CE

More information

INSTALLATION MANUAL. Air Conditioners

INSTALLATION MANUAL. Air Conditioners INSTALLATION MANUAL SYSTEM Air Conditioners MODELS Ceiling Mounted Cassette type (Round Flow with Sensing) FXFQ25SVM FXFQ63SVM FXFQ32SVM FXFQ80SVM FXFQ40SVM FXFQ100SVM FXFQ50SVM FXFQ125SVM CAREFULLY READ

More information

INSTALLATION MANUAL. R32 Split Series. Models ARXM25M2V1B ARXM35M2V1B ARXP20K3V1B ARXP25K3V1B ARXP35K3V1B

INSTALLATION MANUAL. R32 Split Series. Models ARXM25M2V1B ARXM35M2V1B ARXP20K3V1B ARXP25K3V1B ARXP35K3V1B INSTALLATION MANUAL R32 Split Series Models ARXM25M2V1B ARXM35M2V1B ARXP20K3V1B ARXP25K3V1B ARXP35K3V1B RXJ20M2V1B RXJ25M2V1B RXJ35M2V1B RXM20M2V1B RXM25M2V1B RXM35M2V1B RXP20K3V1B RXP25K3V1B RXP35K3V1B

More information

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1 INSTALLATION MANUAL Decoration Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ0D7GW BYCQ0D7GFW BYCQ0D7GW BYCQ0D7GFW Installation manual Contents. SAFETY PRECAUTIONS....

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Option kit for combination of Daikin condensing units with field supplied evaporators 1 3 5 4 1 NOTES 2 11 9 8 10 7 6 1 2 expansion valve gas liquid air remocon outdoor

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners INSTALLATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский. DAIKIN ROOM AIR CONDITIONER Operation Manual FDXS25F2VEB FDXS60F2VEB FDXS35F2VEB FDXS50F2VEB English Deutsch Français Nederlands Español Italiano Ελληνικά Portugues Русский Türkçe CONTENTS READ BEFORE

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R32 Split Series. English. Deutsch. Français. Nederlands. Español. Italiano.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R32 Split Series. English. Deutsch. Français. Nederlands. Español. Italiano. English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R32 Split Series Deutsch Eλληνικά Italiano Portugues Pyccкий Türkçe Español Nederlands Français MODELS CTXM15M2V1B FTXM20M2V1B FTXM25M2V1B FTXM35M2V1B

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. English. Deutsch. Français. Nederlands. Español. Italiano.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. English. Deutsch. Français. Nederlands. Español. Italiano. Deutsch Eλληνικά Italiano Español Portugues Pyccкий Türkçe Nederlands Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series MODELS FTXS20K2V1B FTXS25K2V1B CTXS15K2V1B CTXS35K2V1B

More information

INSTALLATION MANUAL. Four-Way Cassette. Model B-VMH09CU-1 B-VMH12CU-1 B-VMH18CU

INSTALLATION MANUAL. Four-Way Cassette. Model B-VMH09CU-1 B-VMH12CU-1 B-VMH18CU INSTALLATION MANUAL Four-Way Cassette Model B-VMH09CU- B-VMHCU- B-VMH8CU- 57.787.00 www.marsdelivers.com If used as MULTI unit, please refer to the Installation & operation manuals packed with outdoor

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R32 Split Series. English. Deutsch. Français. Nederlands. Español. Italiano.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R32 Split Series. English. Deutsch. Français. Nederlands. Español. Italiano. English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R32 Split Series Deutsch Eλληνικά Italiano Portugues Pyccкий Türkçe Español Nederlands Français MODELS CTXM15M2V1B FTXM20M2V1B FTXM25M2V1B FTXM35M2V1B

More information

INSTALLATION MANUAL. Condenserless water-cooled water chillers

INSTALLATION MANUAL. Condenserless water-cooled water chillers INSTALLATION MANUAL EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ

More information

SPLIT SYSTEM Air Conditioners

SPLIT SYSTEM Air Conditioners INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODEL Ceiling suspended type FHQ24MVJU FHQ30MVJU FHQ36MVJU FHQ42MVJU Read these instructions carefully before installation. Keep this manual in a handy

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXZQAVEB FXZQ0AVEB FXZQAVEB FXZQAVEB FXZQ0AVEB FXZQ0AVEB .. 0~ H H 00 00 8 8 H 9 0 8 H H H 8 8 9 0 L N.. 8 9 0 CE - ATITIKTIES-DEKLARACIJA CE -

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXZQAVEB FXZQ0AVEB FXZQAVEB FXZQAVEB FXZQ0AVEB FXZQ0AVEB .. 0~ H H 00 00 8 8 H 9 0 8 H H H 8 8 9 0 L N.. 8 9 0 CE - DECLARATION-OF-CONFORMITY CE

More information

INSTALLATION MANUAL. System air conditioner. BS unit BSVQ100P8V1B BSVQ160P8V1B BSVQ250P8V1B

INSTALLATION MANUAL. System air conditioner. BS unit BSVQ100P8V1B BSVQ160P8V1B BSVQ250P8V1B INSTALLATION MANUAL System air conditioner READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. BSVQ100P8V1B BSVQ160P8V1B BSVQ250P8V1B CE - ATITIKTIES-DEKLARACIJA

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. English. Deutsch. Français. Nederlands. Español. Italiano.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. English. Deutsch. Français. Nederlands. Español. Italiano. Deutsch Eλληνικά Italiano Español Portugues Pyccкий Türkçe Nederlands Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series MODELS FTXS20K2V1B FTXS25K2V1B CTXS15K2V1B CTXS35K2V1B

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

INSTALLATION MANUAL. R410A Split Series. Models FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B

INSTALLATION MANUAL. R410A Split Series. Models FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B INSTALLATION MANUAL R410A Split Series Models FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o FTX20J2V1B, FTX25J2V1B, FTX35J2V1B Low Voltage 2006/95/EC

More information

INSTALLATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

INSTALLATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B INSTALLATION MANUAL System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

INSTALLATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B INSTALLATION MANUAL System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK

BCF1080 FORWARD PLATE COMPACTORS PARTS BOOK BARTELL MORRISON INC. 375 Annagem Blvd., Mississauga, ON L5T 3A7 Telephone: 1-647-953-4100 Fax: 1-647-953-4101 BCF1080 FORWARD PLATE COMPACTORS Doc. # PB-B19017 Orig. Rel. 10/2013 Curr Rev. - 06 Bartell

More information

INSTALLATION MANUAL. Split system air conditioner RZQ200B8W1B RZQ250B8W1B

INSTALLATION MANUAL. Split system air conditioner RZQ200B8W1B RZQ250B8W1B INSTALLATION MANUAL RZQ00B8WB RZQ50B8WB 000 c A a B b C A a e c B e b C d D d D c a B c e b c a B c e b A a f e f C b A a f e f C b d D d d D d h H h h 5 500 000 5 500 500 (mm) 5 A B 66 66 7-77 765 5 6

More information

INSTALLATION MANUAL. Outdoor unit for air to water heat pump ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERLQ006BAV3 ERLQ007BAV3 ERLQ008BAV3

INSTALLATION MANUAL. Outdoor unit for air to water heat pump ERHQ006BAV3 ERHQ007BAV3 ERHQ008BAV3 ERLQ006BAV3 ERLQ007BAV3 ERLQ008BAV3 INSTALLATION MANUAL ERHQ006BAV ERHQ007BAV ERHQ008BAV ERLQ006BAV ERLQ007BAV ERLQ008BAV CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ CE - IZJAVA

More information

INSTALLATION MANUAL. R410A Split Series. Models ATX20J2V1B ATX25J2V1B ATX35J2V1B ATX20J3V1B ATX25J3V1B ATX35J3V1B

INSTALLATION MANUAL. R410A Split Series. Models ATX20J2V1B ATX25J2V1B ATX35J2V1B ATX20J3V1B ATX25J3V1B ATX35J3V1B INSTALLATION MANUAL R410A Split Series Models ATX20J2V1B ATX25J2V1B ATX35J2V1B ATX20J3V1B ATX25J3V1B ATX35J3V1B DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o ATX20J2V1B, ATX25J2V1B, ATX35J2V1B Low Voltage 2006/95/EC

More information

INSTALLATION MANUAL. Split System Air Conditioner FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB AVA125AMVE

INSTALLATION MANUAL. Split System Air Conditioner FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB AVA125AMVE INSTALLATION MANUAL Split System Air Conditioner FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB AVA125AMVE CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI

More information

INSTALLATION MANUAL. Split System air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB

INSTALLATION MANUAL. Split System air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB INSTALLATION MANUAL FCQGFVEB FCQG0FVEB FCQG0FVEB FCQG7FVEB FCQG00FVEB FCQGFVEB FCQG0FVEB FCQHG7FVEB FCQHG00FVEB FCQHGFVEB FCQHG0FVEB 00 00 * * 90 0-00 7 00 mm ~. m 8 0~7 7 7 80 7 8 9 00 mm 0~7 mm 9 0 8

More information

Please read this manual carefully before installation and keep it for future reference. Installation Manual. Olympus Series Cassette Air Handlers

Please read this manual carefully before installation and keep it for future reference. Installation Manual. Olympus Series Cassette Air Handlers Please read this manual carefully before installation and keep it for future reference. Installation Manual Olympus Series Cassette Air Handlers The design and specifications are subject to change without

More information

Installation Instructions

Installation Instructions 40MBCQ Cassette Ductless System Sizes 09 to 8 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS INDOOR... 5 CLEARANCES INDOOR...

More information

FXFQ-M Ceiling Mounted Cassette Type (Multi Flow)

FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) EDUS 39-600 - F1_a FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) AMERICAS EDUS39-600-F1_a FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) 1. External Appearance...2 2. Specifications...3 3. Dimensions...5

More information

SYSTEM Inverter Air Conditioners READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

SYSTEM Inverter Air Conditioners READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. INSTALLATION MANUAL SYSTEM Inverter Air Conditioners MODELS Ceiling-mounted Duct type FXMQ72MVJU FXMQ96MVJU English Français READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R40A Split Series Français Español Installation manual Manuel Manuel dinstallation dinstallation Manual de instalación MODELS FFQ09Q2VJU FFQ2Q2VJU

More information

INSTALLATION MANUAL. R410A Split Series. Models FTXB20C2V1B FTXB25C2V1B FTXB35C2V1B ATXB25C2V1B ATXB35C2V1B

INSTALLATION MANUAL. R410A Split Series. Models FTXB20C2V1B FTXB25C2V1B FTXB35C2V1B ATXB25C2V1B ATXB35C2V1B INSTALLATION MANUAL R410A Split Series Models FTXB20C2V1B FTXB25C2V1B FTXB35C2V1B ATXB25C2V1B ATXB35C2V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

INSTALLATION MANUAL. System air conditioner. BS unit BS1Q10A7V1B BS1Q16A7V1B BS1Q25A7V1B

INSTALLATION MANUAL. System air conditioner. BS unit BS1Q10A7V1B BS1Q16A7V1B BS1Q25A7V1B INSTALLATION MANUAL System air conditioner READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. BS1Q10A7V1B BS1Q16A7V1B BS1Q25A7V1B 2 1 3 4 5 6

More information

INSTALLATION MANUAL. R32 Split Series. Models RXJ50M2V1B RXM42M2V1B RXM50M2V1B RXM60M2V1B RXP50K3V1B RXP60K3V1B ARXM50M2V1B

INSTALLATION MANUAL. R32 Split Series. Models RXJ50M2V1B RXM42M2V1B RXM50M2V1B RXM60M2V1B RXP50K3V1B RXP60K3V1B ARXM50M2V1B INSTALLATION MANUAL R32 Split Series Models RXJ50M2V1B RXM42M2V1B RXM50M2V1B RXM60M2V1B RXP50K3V1B RXP60K3V1B ARXM50M2V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

INSTALLATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB INSTALLATION MANUAL System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL. R410A Split Series. Models RXS50K2V1B RXS60F4V1B RXG50K3V1B RX50G3V1B RX60G3V1B

INSTALLATION MANUAL. R410A Split Series. Models RXS50K2V1B RXS60F4V1B RXG50K3V1B RX50G3V1B RX60G3V1B INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Installationsanleitung Split-Baureihe R410A Deutsch Models RXS50K2V1B RXS60F4V1B RXG50K3V1B RX50G3V1B RX60G3V1B ARXS50G3V1B

More information

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Split-type Air-Conditioner MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Deutsch Français Nederlands Español Italiano

More information

INSTALLATION MANUAL. System Inverter Air Conditioners FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB

INSTALLATION MANUAL. System Inverter Air Conditioners FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB INSTALLATION MANUAL System Inverter Air Conditioners FXDQ15A2VEB FXDQ20A2VEB FXDQ25A2VEB FXDQ32A2VEB FXDQ40A2VEB FXDQ50A2VEB FXDQ63A2VEB CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

OUTDOOR UNIT INSTALLATION MANUAL MODEL RXLS25M2V1B RXLS35M2V1B RXL25M2V1B RXL35M2V1B ARXL25M2V1B ARXL35M2V1B. R410A Split Series

OUTDOOR UNIT INSTALLATION MANUAL MODEL RXLS25M2V1B RXLS35M2V1B RXL25M2V1B RXL35M2V1B ARXL25M2V1B ARXL35M2V1B. R410A Split Series OUTDOOR UNIT R410A Split Series INSTALLATION MANUAL MODEL RXLS25M2V1B RXLS35M2V1B RXL25M2V1B RXL35M2V1B ARXL25M2V1B ARXL35M2V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL R410A Split Series

INSTALLATION MANUAL R410A Split Series Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Installation manual Manuel dinstallation Manual de instalación MODELS FDMQ09RVJU FDMQ12RVJU FDMQ15RVJU FDMQ18RVJU

More information

INSTALLATION MANUAL Duct Type Series MH FECA

INSTALLATION MANUAL Duct Type Series MH FECA INSTALLATION MANUAL Duct Type Series MH FECA ENGLISH FRANÇAIS ESPAÑOL Free Joint Multi Air Conditioner (Cooling and Heating) E S F DB98-960A() Safety Precautions The following safety precautions must be

More information

INSTALLATION MANUAL. Unit for air to water heat pump system EKCBX008BBV3 EKCBH008BBV3

INSTALLATION MANUAL. Unit for air to water heat pump system EKCBX008BBV3 EKCBH008BBV3 INSTALLATION MANUAL EKCBX008BBV EKCBH008BBV CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ CE - IZJAVA O SKLADNOSTI CE - VASTAVUSDEKLARATSIOON CE

More information

INSTALLATION MANUAL FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU FBQ48PVJU. MODELS Ceiling-mounted Duct type

INSTALLATION MANUAL FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU FBQ48PVJU. MODELS Ceiling-mounted Duct type INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling-mounted Duct type FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU FBQ48PVJU English Français Read these instructions carefully before

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER ATX20KV1B ATX25KV1B ATX35KV1B. R410A Split Series. English. Deutsch. Français.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER ATX20KV1B ATX25KV1B ATX35KV1B. R410A Split Series. English. Deutsch. Français. English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Türkçe Deutsch Eλληνικά Portugues Italiano Español Pyccкий Nederlands Français MODELS ATX20KV1B ATX25KV1B ATX35KV1B CE - ATITIKTIES-DEKLARACIJA

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER FTX20KV1B FTX25KV1B FTX35KV1B FTX50KV1B FTX60KV1B. R410A Split Series. English.

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER FTX20KV1B FTX25KV1B FTX35KV1B FTX50KV1B FTX60KV1B. R410A Split Series. English. English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Türkçe Deutsch Eλληνικά Portugues Italiano Español Pyccкий Nederlands Français MODELS FTX20KV1B FTX25KV1B FTX35KV1B FTX50KV1B

More information

PRO DUAL MINI-SPLIT SPLIT-TYPE FOUR-WAY CASSETTE TYPE ROOM AIR CONDITIONER

PRO DUAL MINI-SPLIT SPLIT-TYPE FOUR-WAY CASSETTE TYPE ROOM AIR CONDITIONER INDOOR CEILING MOUNT PRO DUAL MINI-SPLIT SPLIT-TYPE FOUR-WAY CASSETTE TYPE ROOM AIR CONDITIONER #70006 #70007 #70008 #70009 INSTALLATION MANUAL This manual only describes the installation of the indoor

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

INSTALLATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

INSTALLATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) INSTALLATION MANUAL (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM0FA VAM0FA VAM0FA VAM00FA VAM0FA VAM00FA VAM000FA VAM00FA VAM000FA A B A B C 0 0 00 0-0 D E H G J H 0 F 0 B A C 0 0 0 00-00

More information

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners FDXM5F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B English Table of Contents Table of Contents About the system INFORMATION 1 About this document About the system.1 Components... 3 Operation 3 3.1 Operation

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the

More information

INSTALLATION MANUAL. Split System air conditioners FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB

INSTALLATION MANUAL. Split System air conditioners FBQ35C7VEB FBQ50C7VEB FBQ60C7VEB FBQ71C7VEB FBQ100C7VEB FBQ125C7VEB FBQ140C7VEB INSTLLTION MNUL FBQC7VEB FBQ0C7VEB FBQ0C7VEB FBQ7C7VEB FBQ00C7VEB FBQC7VEB FBQ0C7VEB 7 00 B 0 700 a b c < 00 80 80 7 80 a b c 7a 80 7c 0 (0~00) 0 7b 7a 80 0 0 7b 8 9 7c 0 8 9 00 mm ~. m 00 mm 0~7 0~ mm

More information

INSTALLATION MANUAL. R32 Split series FDXM25F2V1B FDXM35F2V1B FDXM50F2V1B FDXM60F2V1B

INSTALLATION MANUAL. R32 Split series FDXM25F2V1B FDXM35F2V1B FDXM50F2V1B FDXM60F2V1B INSTALLATION MANUAL R32 Split series FDXM25F2V1B FDXM35F2V1B FDXM50F2V1B FDXM60F2V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI CE - IZJAVA O SKLADNOSTI

More information

INSTALLATION MANUAL. Unit for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1

INSTALLATION MANUAL. Unit for air to water heat pump system EDHQ011BB6V3 EDHQ014BB6V3 EDHQ016BB6V3 EDHQ011BB6W1 EDHQ014BB6W1 EDHQ016BB6W1 INSTALLATION MANUAL EDHQ0BB6V EDHQ0BB6V EDHQ06BB6V EDHQ0BB6W EDHQ0BB6W EDHQ06BB6W EDLQ0BB6V EDLQ0BB6V EDLQ06BB6V EDLQ0BB6W EDLQ0BB6W EDLQ06BB6W EBHQ0BB6V EBHQ0BB6V EBHQ06BB6V EBHQ0BB6W EBHQ0BB6W EBHQ06BB6W

More information

Inverter Air Source Heat Pump Monobloc system

Inverter Air Source Heat Pump Monobloc system Inverter Air Source Heat Pump Monobloc system Product Data & Installation Manual AXAI-06M & AXAI-09M AXAI-12M & AXAI-15M TABLE OF CONTENT INSTRUCTIONS 1 This manual 1 Items inside product box. 2 Tools

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A FTX25KMV1B FTX35KMV1B

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A FTX25KMV1B FTX35KMV1B FTX25KMV1B FTX35KMV1B DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI CE - IZJAVA O SKLADNOSTI

More information

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B OPERATION MANUAL System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B Air inlet (top of main unit) Air filter (Under the panel) Name plate (Indoor

More information

INSTALLATION MANUAL. R32 Split Series. Models RXJ20M2V1B RXJ25M2V1B RXJ35M2V1B RXM20M2V1B RXM25M2V1B RXM35M2V1B ARXM25M2V1B ARXM35M2V1B

INSTALLATION MANUAL. R32 Split Series. Models RXJ20M2V1B RXJ25M2V1B RXJ35M2V1B RXM20M2V1B RXM25M2V1B RXM35M2V1B ARXM25M2V1B ARXM35M2V1B INSTALLATION MANUAL R32 Split Series Models RXJ20M2V1B RXJ25M2V1B RXJ35M2V1B RXM20M2V1B RXM25M2V1B RXM35M2V1B ARXM25M2V1B ARXM35M2V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY

More information

INSTALLATION MANUAL. R410A Split Series. Models RXB20C2V1B RXB25C2V1B RXB35C2V1B ARXB25C2V1B ARXB35C2V1B

INSTALLATION MANUAL. R410A Split Series. Models RXB20C2V1B RXB25C2V1B RXB35C2V1B ARXB25C2V1B ARXB35C2V1B INSTALLATION MANUAL R410A Split Series Models RXB20C2V1B RXB25C2V1B RXB35C2V1B ARXB25C2V1B ARXB35C2V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYGUNLUK-BEYANI

More information

INSTALLATION MANUAL. Split System air conditioners RZQS71D7V1B RZQS100D7V1B RZQS125D7V1B RZQS140D7V1B

INSTALLATION MANUAL. Split System air conditioners RZQS71D7V1B RZQS100D7V1B RZQS125D7V1B RZQS140D7V1B INSTLLTION MNUL RZQS7D7VB RZQS00D7VB RZQS5D7VB RZQS40D7VB B D E L C L D H B B D C E H L B L D 4 5 L4 6 E B L L L5 H L H L L L H H L L L4 H H L L L6 L7 H C D H 4 5 6 7 B 9 ~ 50 Hz 0-40 V 4 5 IV 7 8 6 R40

More information

INSTALLATION MANUAL. Unit for air to water heat pump system EDHQ011AA6V3 EDHQ014AA6V3 EDHQ016AA6V3 EDHQ011AA6W1 EDHQ014AA6W1 EDHQ016AA6W1

INSTALLATION MANUAL. Unit for air to water heat pump system EDHQ011AA6V3 EDHQ014AA6V3 EDHQ016AA6V3 EDHQ011AA6W1 EDHQ014AA6W1 EDHQ016AA6W1 INSTALLATION MANUAL EDHQ0AA6V EDHQ0AA6V EDHQ06AA6V EDHQ0AA6W EDHQ0AA6W EDHQ06AA6W EDLQ0AA6V EDLQ0AA6V EDLQ06AA6V EDLQ0AA6W EDLQ0AA6W EDLQ06AA6W EBHQ0AA6V EBHQ0AA6V EBHQ06AA6V EBHQ0AA6W EBHQ0AA6W EBHQ06AA6W

More information

INSTALLATION MANUAL. Split System air conditioners FFQ25C2VEB FFQ35C2VEB FFQ50C2VEB FFQ60C2VEB

INSTALLATION MANUAL. Split System air conditioners FFQ25C2VEB FFQ35C2VEB FFQ50C2VEB FFQ60C2VEB INSTALLATION MANUAL FFQCVEB FFQCVEB FFQ0CVEB FFQ0CVEB .. 0~7 H H H 9 0 7 8 BYFQ0C BYFQ0B H BYFQ0C BYFQ0B H H 8 8 7 9 0 7 7 700 700 7 8 7 7 0 0 7 8 7. 7 0. 8 9 CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA

More information

Installer manual AG-WL10

Installer manual AG-WL10 LEK LED CLEAN TIMER OPERATION Installer manual Indoor unit air/air heat pump IHB GB 1637-1 331827 Table of Contents 1 Important information Safety information Read before starting the installation Electrical

More information

General safety precautions English

General safety precautions English General safety precautions General safety precautions English 1 General safety precautions 1 General safety precautions Units are marked with the following symbol: 1.1 About the documentation The original

More information

INSTALLATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

INSTALLATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) INSTALLATION MANUAL (Ceiling mounted duct type) VAM50FC VAM500FC VAM650FC VAM800FC VAM000FC VAM500FC VAM000FC A B A B C D E F G H J K L VAM50F 6 85 6 800 6 850 758 8 00 VAM500F 8 97 VAM650F 7 96 50 85

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL Option kit for combination of Daikin condensing units with field-supplied air handling units 3 5 4 1 1 2 expansion valve gas liquid air remocon outdoor ON/OFF L N Y1 Y2

More information

INSTALLATION MANUAL DAIKIN ROOM AIR CONDITIONER. Models FTXTP25K3V1B FTXTP35K3V1B ATXTP25K3V1B ATXTP35K3V1B. R32 Split Series. English.

INSTALLATION MANUAL DAIKIN ROOM AIR CONDITIONER. Models FTXTP25K3V1B FTXTP35K3V1B ATXTP25K3V1B ATXTP35K3V1B. R32 Split Series. English. English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R32 Split Series Deutsch Norsk Suomi Svenska Dansk Polski Русский Français Models FTXTP25K3V1B FTXTP35K3V1B ATXTP25K3V1B ATXTP35K3V1B CE - ATITIKTIES-DEKLARACIJA

More information

R410A Split Series INSTALLATION MANUAL MODEL RXL50J3V1B RXLG50K3V1B

R410A Split Series INSTALLATION MANUAL MODEL RXL50J3V1B RXLG50K3V1B R410A Split Series INSTALLATION MANUAL MODEL RXL50J3V1B RXLG50K3V1B CE - ATITIKTIES-DEKLARACIJA CE - ATBILSTĪBAS-DEKLARĀCIJA CE - VYHLÁSENIE-ZHODY CE - UYUMLULUK-BİLDİRİSİ CE - IZJAVA O SKLADNOSTI CE -

More information

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1 OPERATION MANUAL system room air conditioners 1 1 5 6 9 4 7 Pair Paar Paire Pair Par Singolo  ÁÔ Par Сплит 3 2 4 5 ÔÏÏ appleïfi Много 8 1 2a 2b 3a 3b 2a 2b 3a 3b S system room air conditioners CONTENTS

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information