Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

Size: px
Start display at page:

Download "Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector"

Transcription

1 Atmos EasySolar Installation Instructions for Atmos EasySolar Sloping roof and flat roof installation with evacuated tube collector Atmos Heating Systems TBS Building Supplies Ltd Hackwood Road Daventry Northants, NN11 4ES Tel: Fax: internet: Issue

2 Atmos EasySolar Installation Instructions Evacuated Tube Collector Table of Contents 1 Introduction System Components Siting & requirements Installation Safety & insulation Storage tank Domestic water connections Hard water Tank in unheated space Protection of plastic pipe and pipe insulation Vented hot water systems Unvented hot water systems Connection to combi boiler Connection to an unvented hot water cylinder Connection to a vented hot water cylinder Evacuated tube collector on sloping roof Evacuated tube collector on flat roof Filling the tank Flushing the pump Connecting the collector circuit Connecting the optional booster pump Maintenance Technical specifications Commissioning checklists

3 Atmos Heating Systems 1 Introduction Thank you for purchasing an Atmos EasySolar hot water system. This will provides you with free hot water for many years to come, provided that it is correctly installed and maintained. Most of us dislike reading installation manuals, and prefer to fit it and read later, so we have summarised some of the 7 most important installation requirements below, BUT, please do not use this as an excuse not to read the manual properly. Remember that the warranty will be invalidated if the installation is not correct. 1. LOCATION; Ideally the solar collectors should be facing directly south, and mounted on a slope of between 30 and 40 degrees to the horizontal. Any deviation from this will result in less energy being collected, although between south east and south west it will at most result in less than 10% loss of performance. 2. SHADING. If there are trees or buildings shading the location of the solar collectors, this will also reduce the performance. Ideally there should be no shading. 3. DO NOT fit the collector on a slope of less than 20 degrees. If you do the system will not only lose performance, but the drain back action will be impaired. That means the collectors will freeze and break in the cold winter. In the summer it will cause boiling, which is dangerous. 4. The storage tank MUST be located below the header of the evacuated tube collector. 5. The storage tank is fitted with a pump which has a 3m or 4m head. The vertical distance between the base of the tank and the top of the solar collector MUST NOT be greater than the pump head. If it is, the system will not work. A booster pump is available from Atmos to give additional pump head if you make a mistake, but they are not cheap. 6. The pipes from the collector to the storage tank MUST have a continuous slope down towards the tank, otherwise the drain back will not work. They must be properly fixed so that they cannot droop or sag, or be pulled down by someone. 7. PLEASE make sure you use the insulation provided on the red and blue pipes, and make sure it is neatly and correctly fitted. Up to 20% of the heat collected by the solar collector can be lost if the insulation is not fitted (or badly fitted). 3

4 Atmos EasySolar Installation Instructions Evacuated Tube Collector 2 System Components Boxes and parts The system is packaged in several boxes. Check that the boxes are not damaged and that you have received the correct boxes for the system you have ordered. See table below. Inform your supplier if you have received incorrect or damaged boxes. Numbers of boxes per system TC = tube collector S = sloping roof F = flat roof Storage tank 100L 3M Article No Storage tank 100L 4M Article No Tube collector Article No Tube collector Article No Tube collector Article No EasySolar 15TC S 3M Article No EasySolar 20TC S 3M Article No EasySolar 24TC S 3M Article No EasySolar 15TC S 4M Article No EasySolar 20TC S 4M Article No EasySolar 24TC S 4M Article No Installation kit sloping roof Article No Installation kit flat roof Article No EasySolar 15TC F 3M Article No EasySolar 20TC F 3M Article No EasySolar 24TC F 3M Article No EasySolar 15TC F 4M Article No EasySolar 20TC F 4M Article No EasySolar 24TC F 4M Article No For sloping roof installations specify which roof bracket is required *1]Standard *1]Medium *1]Wide *2]Slate *3]Bitumen/wall (roof bracket 30-39mm) (roof bracket k mm) (roof bracket mm) *1] *2] *3] 4

5 Atmos Heating Systems Components in installation kits picture Sloping roof Flat roof Installation and User Instructions 1 1 Adaptor 12 Volt 1 1 Wakaflex 1 0 Collector return pipe blue L=650cm 1 1 Collector flow pipe red (insulation supplied loose) L=650cm 1 1 Insulated flexible connecting pipes for domestic water L=90 cm incl. rings 2 2 Flow restrictor 1 1 Elbow 2 2 Compression elbow 2 2 5

6 Atmos EasySolar Installation Instructions Evacuated Tube Collector Pipe gland 0 1 Filling plug 1 1 Overflow plug 1 1 Overflow connector 1 1 Yellow filling hose with connector ¾ 1 1 6

7 Atmos Heating Systems 3 Siting & requirements When choosing the location for the storage tank the following needs to be considered: The vertical distance between the base of the tank and the top of the collectors should not exceed the combined capacity of the storage tank pump and any booster pump that may be added to provide extra pump height. The distance between the storage tank and the appliance (combi boiler or hot water cylinder) to which pre-heated water is supplied, needs to be kept as short as practical. The storage tank needs to be sited on a firm horizontal surface that is able to take the weight when the tank is filled with water (116kg). Atmos supply a brackets and shelf set for optional wall mounting of the storage tank. The following are needed in the vicinity of the storage tank: o 240V electrical socket within 1.5 meter distance o Water tap with ¾ bsp hose union connection within 2.5 meter distance It is preferable to locate the storage tank and the connecting domestic water pipes in a frost free room. If the tank is installed in an unheated space particular care must be taken to protect the domestic water pipes against freezing. See paragraph 4.5. The following tools are needed to install the system: Sloping roof Spanner 24 mm Spanner 8 mm Tape measure HSS drill bit 5 mm Sharp knife Hole saw 30 mm Battery drill with pozi bit Ducting tape Flat roof Ballast (paving slabs) Spanner 24 mm Spanner 8 mm Tape measure Hole saw 50 mm Sharp knife Rubber tiles for roof protection Roof sealant for roof penetration Ducting tape 7

8 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4 Installation 4.1 Safety & insulation Before you start work consider your own safety and that of others. The EasySolar hot water system has electrical parts. Apart from the adaptor which plugs into the 240V socket, these parts are all low voltage (12V) and therefore perfectly safe. However it is advisable to take care not to damage any electrical insulation and to avoid electrical parts becoming wet. The heat exchanger and the flexible connecting pipes for domestic water are subject to mains water pressure and can become hot. For this reason the flexible connecting pipes for domestic water need to be insulated. Insulation for these pipes is included in the assembly kit. The insulation must extend over the connections to the tank. Secure the insulation with tape. Ensure that the tank and connecting pipes have cooled down before any maintenance work is undertaken. The tank and connecting pipes can be cooled down by drawing off hot water. The pipes connecting the storage tank and the collectors can also become hot. The red flow pipe needs to be insulated along its full length. Insulation for this pipe is included in the assembly kit. Ensure that the pipes have cooled down before any maintenance work is undertaken. Assemble all components according to the installation instructions and avoid components getting damaged during installation or subsequent use. Put in place sufficient safety measures when working on the roof. Use scaffolding if necessary. 8

9 Atmos Heating Systems 4.2 Storage tank Connections Filling Collector cold Collector hot Collector sensor Domestic water hot Domestic water cold Domestic water connections The flexible connecting pipes provided in the assembly kit are for the domestic water hot and cold connections. Use the washers for sealing the connection between the flexible pipes and the storage tank. The blue connecting point is for incoming cold water and the red connecting point is the outlet for pre-heated domestic water. The mains water pressure should be no more than 8 bar. If the mains water pressure is likely to exceed 8 bar, a pressure reducing valve should be fitted before connection to the storage tank. 4.4 Hard water In areas of hard water (hardness in excess of 200ppm) an approved water conditioner device must be fitted in accordance with the Building Regulations. Atmos can supply a suitable conditioner for fitting to the cold feed to the storage tank. In areas of hard water, failure to fit a suitable conditioner will invalidate the warranty. 4.5 Tank in unheated space If the tank is installed in an unheated space particular care must be taken to protect the domestic water pipes against freezing. Insulation for the domestic water flexible connecting pipes is supplied with the assembly kit. It may be necessary to apply additional insulation to these pipes and to other domestic water pipes particularly if the unheated space is subject to draught. 9

10 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4.6 Protection of plastic pipe and pipe insulation The red and blue collector pipes are made of plastic. It can occur that plastic pipes or pipe insulation material is damaged by rodents such as mice, rats or squirrels. Take appropriate precautions to protect the pipes and insulation material from this kind of attack if considered necessary. 4.7 Vented hot water systems The Atmos EasySolar system can be used as a preheat tank with a vented hot water system. The base of the cold water feed tank must be at least 1m above the base of the EasySolar tank, and the cold feed to the hot water cylinder passes through the cold/hot connections of the EasySolar tank. In most cases where the cold tank is in the roof space, a platform will be required of strong construction in accordance with the current standards. 4.8 Unvented hot water systems The Atmos EasySolar system can be used to provide preheated water to an unvented hot water cylinder. However the pressure reducing valve assembly as fitted on the cold water inlet feed of an unvented cylinder must be fitted before the EasySolar tank, and then the warm outlet from the EasySolar tank is connected to the cold inlet on the hot water cylinder (see page 12) 4.9 Connection to combi boiler The Atmos EasySolar hot water system can be used provide preheated water to a combi boiler. However the following points must be noted; a) If the boiler is solar compatible (eg Atmos HE32 InterCombi) it can be connected directly to the cold water inlet as per the diagram on page 11. b) If the boiler is not solar compatible, but can accept cold water at 28 deg C, a Combisol valve must be fitted (available from Atmos) c) In all cases for combi boilers which are not solar compatible, the installer should check with the manufacturers that the boiler is able to accept cold water at 28 deg C inlet. If this is not acceptable, then an EasySolar system should not be fitted, or the boiler should be changed to a solar compatible type. 10

11 Atmos Heating Systems Connection to combi boiler EXPLANATORY NOTES: 1) TMV1 is a non-adjustable thermostatic mixer valve. Connect as shown and ignore the arrows on the body of the valve. This is a diverter valve and works in reverse. The operation is that if the water from the solar storage tank is greater than 45 deg C, it goes straight to the taps. If it is lower it is diverted through the boiler and is heated up. 2) TMV2 is an adjustable thermostatic mixer valve with a black adjuster head. This should be fitted as shown, and the arrows on the body are correct. K means Cold (cold inlet), W means Warm (hot inlet), and M means Mixed (or blended) out to the taps. Adjust hot water to desired tap outlet temperature (clockwise gets colder, and anti-clockwise gets warmer). CONNECTIONS: 1) Heated water from solar store connects into M on TMV1 2) W on TMV1 connects into cold inlet on combi boiler 3) K on TMV1 connects to W on TMV2 with T-off from domestic hot water outlet on combi boiler. 4) Incoming cold water connects into K on TMV2 5) M on TMV2 connects to domestic hot water taps 11

12 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4.10 Connection to an unvented hot water cylinder The Atmos EasySolar hot water system can provide pre-heated water to an unvented hot water cylinder. The diagram below shows how the EasySolar system is connected to an unvented hot water cylinder. EXPLANATORY NOTES: 1. The pressure reducing valve and the 6 bar pressure relief valve must be fitted before the solar storage tank and before the T-off to the cold connection on the thermostatic mixer valve. 2. No valve must be fitted between the unvented cylinder and the solar storage tank or between the solar storage tank and the pressure relief valve. 12

13 Atmos Heating Systems 4.11 Connection to a vented hot water cylinder The Atmos EasySolar hot water system can provide pre-heated water to a vented hot water cylinder. The diagram below shows how the EasySolar system is connected to a vented hot water cylinder. 13

14 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4.12 Evacuated tube collector on sloping roof Fixing profiles: The length of the fixing profiles various according to the number of evacuated tubes. The image below shows the flow and return connections on the rear side of the collector header. return flow 14

15 Atmos Heating Systems Assemble the frame as shown: Remove the tiles where the roof hooks are to be located. Place the roof hooks in the valley of the tile and hook behind the roof batten. The width of the frame can be adjusted to fit the position of the roof hooks. Determine the location of the remaining 4 roof hooks and drill 8.5mm holes in the profiles A to fix the roof hooks to the profiles A. After this the tiles can be replaced. 15

16 Atmos EasySolar Installation Instructions Evacuated Tube Collector Once the frame and the roof hooks have been fixed to the roof the header can be fitted to the frame. It is important that the header is fitted level, so that the water in the header drains back correctly. Use an angle grinder to cut a section out of a roof tile. Cut two pieces of wakaflex each 50cm long. Use a hollow punch to make two 20mm holes in one of the two pieces of Wakaflex. Fix the pipe gland to the holes. If the correct size hollow punch is not available it is possible to use a 22mm compression ring instead. Place the wakaflex with the pipe gland over the tile with the section cut out and underneath the tile higher up. Do not stick the wakaflex down till after the red and blue collector pipes have been taken through the pipe gland. Place the second piece of wakaflex on top and above the first piece and underneath the tiles higher up. 16

17 Atmos Heating Systems hot cold 17

18 Atmos EasySolar Installation Instructions Evacuated Tube Collector Fit the compression elbows to the pipes coming out at the rear of the header. Connect the red and blue collector pipes and take these through the pipe gland. Ensure that AT ALL POINTS THE PIPES SLOPE DOWN away from the collector header. Fit the pipe insulation to the red and blue collector pipes. Ensure that there is enough slack in the pipes for thermal contraction (max 5%). Stick the wakaflex to the tiles. Fit the evacuated tubes and the fixing cups. Apply the heat transfer paste to the metal ends of the glass tubes. Using soapy liquid on the ends of the glass tubes will make it easier to slide them in. Fixing cup: 18

19 Atmos Heating Systems End result: The sensor cable from the collector header should be taken underneath the roof tiles and down to the storage tank. The flow and return pipes must at all points slope down towards the storage tank. This is essential in order for the water in the collectors and in the pipes to flow back to the storage tank when the pump is not running. Ensure that there is no tension on the flow and return pipes or leakage may occur. The red flow pipe should be insulated along the whole of its length, using the pipe insulation provided. The blue return pipe should be insulated only above roof level. The sensor cable can be extended if necessary using a two wire cable. 19

20 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4.13 Evacuated tube collector on flat roof Assemble the frame. There are different options with regard to the angle of the collector. The lowest possible angle is 35. Place rubber tiles for roof protection underneath the frame. The horizontal L profiles for the ballast are needed when ballast is used. Ensure that the L profiles are secured under the ballast and cannot slide free. Fit the header to the frame and insert the glass tubes. Ensure that the header is level. This is necessary so that the water in the header drains back correctly. Apply the contact paste to the metal ends of the glass tubes. Soapy water can be used to make it easier to slide the glass tubes into the sockets on the header. 20

21 Atmos Heating Systems Put ballast on the four corners of the frame. The tables show the minimum required ballast weight in kg needed to secure the collector. This applies for collectors at 35 angle. Area I is an area of the country prone to high winds. Area II is an area with medium high winds. Area III has normal or moderate winds. Minimum required ballast for 15 tube collector Built up area Open countryside Height above ground [m] Area I Area II Area III Area I Area II Area III

22 Atmos EasySolar Installation Instructions Evacuated Tube Collector Minimum required ballast for 20 tube collector Built up area Open countryside Minimum required ballast for 24 tube collector Built up area Open countryside Height above ground[m] Area I Area II Area III Area I Area II Area III Height above ground[m] Area I Area II Area III Area I Area II Area III The ballast figures apply for a collector angle of 35. Collector angles more than 35 require greater ballast weight. 22

23 Atmos Heating Systems Drill a 60mm hole in the roof Fit the compression elbows to the pipes coming out at the rear of the header. Connect the red and blue collector pipes. Take the red and blue collector tubes and the sensor cable through the pipe gland to the storage tank. Ensure that AT ALL POINTS THE PIPES SLOPE DOWN away from the collector header and also ensure that there is enough slack in the pipes for thermal contraction (max 5%). Fix and seal the pipe gland to the roof using roof sealant. Fit insulation to the red collector tube along the whole of its length and to the blue collector tube only above roof level. The pipes must be fixed sufficiently to prevent excessive movement on occasions of strong wind. 23

24 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4.14 Filling the tank The procedure for filling the storage tank with water is as follows: Remove the plug from the overflow outlet and insert the overflow connector. Put a tray or bucket underneath to catch any water coming out. Use the yellow hose provided for filling the tank. Insert this into the filling connection point on the tank. Fill the tank slowly with clean water. Make sure the yellow hose is held firmly in position whilst water is flowing into the tank. Stop filling as soon as water flows from the overflow outlet. Allow the surplus water to flow out before replacing the overflow plug and inserting the filling plug. 24

25 Atmos Heating Systems 4.15 Flushing the pump It is necessary to flush the pump in order to remove any air. The procedure for this is as follows: Connect the two connection points on the tank for the collector pipes with a short length of pipe (can be either red or blue). Connect the two terminals on the sensor cable connection point using a short piece of wire. Supply power to the storage tank through the 12V adaptor. The pump will start running. Leave it running for one minute before removing the short piece of wire and the short length of pipe Connecting the collector circuit Connect the collector flow and return pipes to the connectors on the tank. To avoid leaks ensure that the pipe ends have been cut square. Before connecting the blue pipe to the tank, insert the flow restrictor to a depth of at least 3cm. Connect the sensor cable from one of the collectors to the sensor cable connecting point on the tank. Fit the pipe insulation provided for this purpose to the red collector flow pipe along its full length. 25

26 Atmos EasySolar Installation Instructions Evacuated Tube Collector 4.17 Connecting the optional booster pump A booster pump is a pressure activated pump which serves the purpose of increasing the total pump height of the system. It must be fitted to the wall with the pipe connections at the top. The booster pump must not be above the overflow level of the tank and not lower than 500mm below this level. It is connected to the blue collector return pipe and it has its own power supply through a 12V adaptor. Flow restrictor Note! The flow restrictor is not fitted at the connection to the tank but at the connection to the booster pump. 26

27 Atmos Heating Systems 5 Maintenance Storage tank Annually check the sensor wiring and top up the tank. See 4.14 Collectors Annually check the collector. Remove any debris and check that the collector is still firmly fixed. Check that no water can leak through the roof. Pipes Do a yearly check on the pipes to ensure that the pipe insulation is still in place and properly secured and that the collector pipes are correctly sloping down towards the storage tank at all points. Faults The dial on the front of the tank gives an indication of the amount of heat stored in the tank. If the storage tank is not collecting heat even though the sun shines this indicates a fault. To check for any malfunction follow the following procedure. This will only work when the sun is shining. Ensure the storage tank is cold by drawing off hot water. This may take 10 minutes if the storage tank is very warm to start with. 1. Is there 240V on the socket? Yes=>2, No=>13 2. Is there 12V feed to the storage tank? Yes=>3. No=>4 3. Are the wires from the collector thermostat and the 12V feed to the tank connected correctly? Yes=>6. No=>5 4. The 12V adaptor is faulty. Atmos can supply a replacement. 5. Ensure the wires are connected correctly. The wires from the collector thermostat are interchangeable. Does the pump start up within 10 minutes? Yes=>6, No=>7 6. Does the red pipe become warm after a few minutes? No=>8 7. Disconnect the wires to the collector thermostat from the connector block on the tank and then connect the two terminals on this block with a short piece of wire. Does the pump start up? Yes=>9, No=>10 8. Unplug the 12V adaptor from the socket. Top up the tank with water. Plug the 12V adaptor back into the socket. Does warm water begin to flow into the tank after a few minutes? Yes=>12, No=>11 9. The collector thermostat is faulty or the wiring to the collector thermostat is interrupted. 10. There is a fault with the storage tank pump or the wiring to the pump is interrupted. 11. Are the red pipe and the blue pipe to the collectors sloping back towards the storage tank at all points? Yes=>14. No=> Check the system for leakage. 13. Ensure there is 240V on the socket. 14. Check the flow restrictors for blockages. There is one flow restrictor for each collector and one for the storage tank. 15. Ensure that the red pipe and the blue pipe to the collectors are sloping back towards the storage tank at all points. Flush the pump on the storage tank as described in

28 Atmos EasySolar Installation Instructions Evacuated Tube Collector 6 Technical specifications Evacuated tube collector Dimensions 15 tubes 1925 x 1184 x 135mm (length x width x height) 20 tubes 1925 x 1560 x 135mm 24 tubes 1925 x 1855 x 135mm Installation angle (from horizontal) Between 20 and 80 Absorber element Evacuated double glass tube Frame material Aluminium Pipes in collector header Copper Test standard EN12975 / Solar Keymark 28

29 Atmos Heating Systems Storage Tank General Storage volume Weight empty Weight filled 100L 16 kg 116 kg Dimensions Domestic water sided Content 1,5 L Maximum pressure 800 kpa Maximum temperature 80 C Connections ½ BU Pressure drop: Collector sided Content 98,5L Medium clean drinking water Maximum pressure no pressure Maximum temperature 80 C Connections 10mm dismountable push-fit Electrical Power supply 12 V/DC 29

30 Atmos EasySolar Installation Instructions Evacuated Tube Collector 7 Commissioning checklist 30

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors Atmos EasySolar Installation Instructions for Atmos EasySolar In-roof and flat roof installation with flat plate collectors Atmos Heating Systems West March Daventry Northants, NN11 4SA Tel: 01327 871990

More information

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm

More information

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending. SEQUENTIAL THERMOSTATIC SHOWER VALVE 150mm Inlet Pipe Centres Shower Control Handles and Concealing Plate may differ depending on Model OWNER S GUIDE ISSUE 02 These instructions cover all exposed or concealed

More information

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS 1. Important information 1 2. Cleaning & Aftercare

More information

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower e x p e r i e n c e d e s I g n i n n o v a t i o n You re Guide to the Installation, Care and maintenance of Francis Pegler Memento Single Sequential Exposed Thermostatic Shower For further information,

More information

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2 BLADE BATH MIXER DECK MOUNTED CHR WITH KIT 20007014600 INSTRUCTIONS P5-65511339-1-BS-E A/2 20007014600 INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future

More information

Enzo Concealed Shower Mixing Valve

Enzo Concealed Shower Mixing Valve Enzo Concealed Shower Mixing Valve EZ40010CP, EZ40013CP & EZ40014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible.

More information

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning Product Specification Minimum Pressure 0.5 bar Maximum Pressure 4.0 bar Cold Supply Temperature 4-20 c Hot Supply Temperature 55-65 c 1/2" male inlets 1/2" male outlet 38c Temperature stop position Minimum

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification Product Specification ~ Minimum Working Pressure 0.5 bar ~ Maximum Working Pressure 4.0 bar ~ Cold Water Supply Temp 4-20 c ~ Hot Water Supply Temp 55-85 c ~ Fixing Centres 150mm +/- 20mm ~ Outlet size

More information

INTA ION MODERN BAR / BATH SHOWER MIXER CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP INTA ION MODERN BAR / BATH SHOWER MIXER 910000CP INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER Page 1 of 10 INTRODUCTION This installation guide has

More information

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation guide Billi B-3000 Sparkling Dual levered slimline tap option Installation requirements. IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance with AS/NZS

More information

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot

More information

Telo Shower Mixing Valve TL10016CP

Telo Shower Mixing Valve TL10016CP Telo Shower Mixing Valve TL10016CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

Plus Bath Shower Mixing Valve CP and PL30020CP

Plus Bath Shower Mixing Valve CP and PL30020CP Plus Bath Shower Mixing Valve 920000CP and PL30020CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot

More information

Morco House Riverview Road Beverley HU17 0LD

Morco House Riverview Road Beverley HU17 0LD Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi

More information

HW3 Handwash Installation and Operating Instructions

HW3 Handwash Installation and Operating Instructions HW3[16]instructions 10/12/15 14:05 Page 1 HW3 Handwash Installation and Operating Instructions IMPORTANT SAFEGUARDS SPECIFICATION: HW3 RATING: 230-240V, 3000W, ~50Hz; DIMENSIONS: 170w x 190h x 80d mm;

More information

Inta City Concealed Shower Mixing Valve CT80010CP

Inta City Concealed Shower Mixing Valve CT80010CP Inta City Concealed Shower Mixing Valve CT80010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER ENERSTORE Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER Newark Copper Cylinder Co Ltd Brunel Drive Newark Notts. NG24 2EG Tel: 01636 678437 Fax: 01636 678964 Internet: www.newarkcoppercylinder.co.uk

More information

Inta City Shower Mixing Valve CT20010CP

Inta City Shower Mixing Valve CT20010CP Inta City Shower Mixing Valve CT20010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

Puro Mini Dual Control Shower Mixer PU90010CP

Puro Mini Dual Control Shower Mixer PU90010CP Puro Mini Dual Control Shower Mixer PU90010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning Product Specification Minimum Pressure 0.5 bar Maximum Pressure 4.0 bar Cold Supply Temperature 4-20 c Hot Supply Temperature 55-65 c 1/2" male inlets 1/2" male outlet 38c Temperature stop position Minimum

More information

INTADUO THERMOSTATIC BATH/SHOWER MIXER

INTADUO THERMOSTATIC BATH/SHOWER MIXER INTADUO THERMOSTATIC BATH/SHOWER MIXER INSTALLATION, OPERATING AND MAINTENANCE PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER INTRODUCTION This installation guide has been produced for the Inta range of

More information

Deluge Shower Mixing Valve 10045CP

Deluge Shower Mixing Valve 10045CP Deluge Shower Mixing Valve 10045CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v Installation, Operation & Maintenance Pod-PV, Pod-ST v1.1 80030 16 Solar thermal connections (Pod ST only) 15 1 4 5 14 1 2 3 Hot water connections (Pod ST and Pod PV) 17 1 Clearline PV 7 8 2 3 2 3 6 9

More information

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C, Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C, EXD SHCVO C, SAI SHCVO C, GLR SHCVO C, BRG SHCVO C, HOU SHCVO

More information

by Water Purification Supplies

by Water Purification Supplies REVERSE OSMOSIS PURIFIER With Booster Pump by Water Purification Supplies Member, Water Quality Association Read these instructions carefully before using the purifier. Retain these instructions in safe

More information

Morco House Riverview Road Beverley HU17 0LD

Morco House Riverview Road Beverley HU17 0LD Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Combi Boilers - Poor Hot Water Delivery Combi

More information

Traditional Rigid Riser With Eight Inch Rose

Traditional Rigid Riser With Eight Inch Rose Traditional Rigid Riser With Eight Inch Rose BS20007013035 This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification)

More information

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as

More information

Kiko Bath Shower Mixing Valve KK90015CP

Kiko Bath Shower Mixing Valve KK90015CP Kiko Bath Shower Mixing Valve KK90015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

Thermostatic Bar Valves

Thermostatic Bar Valves Thermostatic Bar Valves Installation & operating guide Please leave this installation & user guide with the end user CONTENTS 1. Product Variants 1 2. Important information 2 3. Cleaning & Aftercare 3

More information

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual POWERFLOW Series Unvented Electric Storage Water Heaters Installation & Operating Instructions Manual These Instructions must be left with the user after installation. Version 3.0 June 2009 Hyco POWERFLOW

More information

user manual Dishwasher ESL 46510

user manual Dishwasher ESL 46510 user manual Dishwasher ESL 46510 2 electrolux CONTENTS Electrolux. Thinking of you. Share more of our thinking at www.electrolux.com Safety information 2 Product description 5 Control panel 5 Use of the

More information

Installation guide Sahara & Sahara Plus

Installation guide Sahara & Sahara Plus Installation guide Sahara & Sahara Plus Installation requirements. Components for Billi Sahara 310, 320, 360 & 3120 Models Before commencing installation, ensure you have identified the following. 1. Underbench

More information

Mio Concealed Shower Mixing Valve MI40010CP

Mio Concealed Shower Mixing Valve MI40010CP Mio Concealed Shower Mixing Valve MI40010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any

More information

IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head

IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head IN00333 (rev C) Quadrant Shower Cabin with Monsoon Head Before You Start: General Unpack and check the product is complete and undamaged. WARNING: Shower tray is fragile, HANDLE WITH CARE. The shower tray

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION SOLARCYL IM/SC INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting any unvented

More information

Atmos Energy. Thermostatic Concentric Mixer Valve with Overhead. Fitting Instructions

Atmos Energy. Thermostatic Concentric Mixer Valve with Overhead. Fitting Instructions Atmos Energy Thermostatic Concentric Mixer Valve with Overhead Fitting Instructions IMPORTANT This Step-by-Step guide should be retained after installation. 1. INTRODUCTION This booklet contains all the

More information

Deluge Concealed Shower Mixing Valve DL40010CP

Deluge Concealed Shower Mixing Valve DL40010CP Deluge Concealed Shower Mixing Valve DL40010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

User Manual for MullToa 10 and 25

User Manual for MullToa 10 and 25 User Manual for MullToa 10 and 25 User Manual for MullToa 10 and 25 Congratulations on your purchase of MullToa toilet Your bio-toilet is patented and manufactured in Sweden and the brand is MullToa.

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION Thermostatic Mixer Shower System NOTICE The instruction manual includes part lists, installation instructions, usage of thermostatic and suitable inlet system. Make sure the installation

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding

More information

Installation & Operating Guide

Installation & Operating Guide HOT WATER DISPENSER Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

Self-help Temperature Adjustment

Self-help Temperature Adjustment Self-help Temperature Adjustment The Shower Valve temperature is pre-set to 42 C, but on certain installations the temperature may need to be adjusted. Note: The hot water supply must be above 60 C. Turn

More information

Itho Solar System CombiSolar 150. Installation and service manual

Itho Solar System CombiSolar 150. Installation and service manual Itho Solar System CombiSolar 50 Installation and service manual Pre-heat drain back solar system with unvented hot water solar cylinder for use with combination boilers SOLAR Key Mark Certificated Building

More information

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd 1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk

More information

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE SCHWAN INSTALLATION GUIDE For Schwan Versatap SC52E Instant Hot Cold Filtered Water FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Powerflow Unvented water heater

Powerflow Unvented water heater Product Instruction Manual Powerflow Unvented water heater 30, 50 and 90 litres v15.6/5 Thank you for purchasing a Powerflow series unvented electric water heater. The Powerflow is suitable for hand washing

More information

POWER SHOWERS Models 4500M 5002M 4500T 5002T

POWER SHOWERS Models 4500M 5002M 4500T 5002T II POWER SHOWERS Models 4500M 5002M 4500T 5002T Performance Shower Products CUSTOMER SERVICE HELPLINE: 01883 730339 CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY: This booklet covers all models in

More information

Empura Water Filter. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Empura Water Filter. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts Empura Water Filter Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Important Safety Information Please read these instruction

More information

Dual Control Concealed & Exposed Thermostatic Shower Valve

Dual Control Concealed & Exposed Thermostatic Shower Valve Dual Control Concealed & Exposed Thermostatic Shower Valve Installation & Operating Guide Please leave this Instruction Manual with the end user CONTENTS 1. Important information 1 2. Cleaning & Aftercare

More information

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT GUARANTEE & AFTERCARE When installing or using tools, extra care must be taken to avoid damaging the finish or fitting. To maintain

More information

Thermostatic Concealed Shower Valve

Thermostatic Concealed Shower Valve Thermostatic Concealed Shower Valve Product may differ from image. Please retain this booklet for future aftercare reference Component Breakdown - Three Handle Valve Component breakdown Two Handle Valve

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS BATH SHOWER MIXER WITH KIT UB422DC/L/U/B INSTRUCTIONS INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future reference. General Installation Requirements.

More information

installation INSTRUCTIONS

installation INSTRUCTIONS installation INSTRUCTIONS Shower Waste Water Heat Recovery System These instructions are to be left with the user. 1. Introduction The RECOUP Easyfit+ is a Waste Water Heat Recovery System for shower water

More information

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters Zip Tudor Installation Section & Operating Heading Instructions Single point open outlet (vented) water heaters Affix Model Number Label Here 81333 Above-Sink Tudor (No tapware included) Accessory Tapware

More information

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces. 3 Remove concealing plate KIRI Concealed Mixer Valve ABS Undo nuts (9) on both hot and cold inlets and remove filter washer KIRI VA (6) Installation Instructions & Maintenance Guide 5 Rinse filter washers

More information

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance. TAP6000 3 in Hot Tap Guarantee (UK only): 04-7 Your tap has the benefit of a comprehensive manufacturer s guarantee, details of which are shown on your Proof of Purchase Document. Any claim during the

More information

INSTALLATION GUIDE NZ AU C

INSTALLATION GUIDE NZ AU C DISHWASHER DW60 models INSTALLATION GUIDE NZ AU 591217C 12.17 1 SAFETY AND WARNINGS! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit breaker.

More information

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...

More information

BMW E36 Thermostat Removal And Coolant Flush

BMW E36 Thermostat Removal And Coolant Flush BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could

More information

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1 Rise Digital Bath with overflow filler The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical and Electronic

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL F OR I NGROUND P OOLS INSTALLATION AND OPERATION MANUAL How Solar Pool Heating Works Why SunHeater TM Works Best Using your pool pump, water is automatically pumped through the solar collectors. The water

More information

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS DIAL EXPOSED THERMO SHOWER VALVE For any further information please contact Crosswater on: Or visit our web-site at www.crosswater.co.uk The manufacturer reserves the right to make technical modifications

More information

Zen Boiling Tap Range

Zen Boiling Tap Range Product Instruction Manual Zen Boiling Tap Range Zen Solo, Zen Spa, Zen Life Tap Range v16.10/3 Version 3.2 Jan 2015 Overview The Zen Boiling Tap Range delivers elegant practical solutions for your domestic

More information

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER. METIS Riser rail kit Installation instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180531A September 2006 CONTENTS Page General installation notes 1 Main components

More information

RAMOR Shower Tower Thermostatic mixer Installation and Operating Instructions

RAMOR Shower Tower Thermostatic mixer Installation and Operating Instructions RAMOR Shower Tower Thermostatic mixer Installation and Operating Instructions Installers please note these instructions are to be left with the user 2180513B March 2006 CONTENTS Page Introduction 1 Safety

More information

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION Ecoline Geo RI HP INSTALLATION MANUAL The Ecoline GEO is an indirect unvented cylinder designed and approved for use with a heat pump. The

More information

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION 0 RD 0 RI 0000-06 IM/ IM/a INSTALLATION MANUAL This manual gives detailed advice for installation and should be read carefully prior to fitting

More information

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW 3rd Fold 1st Fold NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW 2nd Fold Please tape down Please tape down Affix Stamp Installation Instructions

More information

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE 1 SCHWAN INSTALLATION GUIDE For Schwan SC60 FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your Schwan system. 2 INFORMATION AND SAFETY

More information

INDIRECT SYSTEM FOR FROST LOCATIONS

INDIRECT SYSTEM FOR FROST LOCATIONS SOLAR WATER HEATING INDIRECT SYSTEM FOR FROST LOCATIONS EFFICIENT USE OF NATURAL SOLAR ENERGY FROM THE DOMESTIC SOLAR WATER HEATERS WITH SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES Solar Water Heaters

More information

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627** Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627** www.thesignaturekitchen.com 2 Contents 1. Precaution before installation... 3 2. Product and Cutout dimension... 4 3. Precaution when moving the

More information

Thermostatic Shower Tower Installation and Operating Instructions

Thermostatic Shower Tower Installation and Operating Instructions Thermostatic Shower Tower Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180396D November 2005 CONTENTS Page Introduction 1 Safety warnings

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST HOME INSPECTION CHECKLIST Date: Page 1 of 9 Client Name: Address: Tel No: Surname: Email: A WATER METER 1 Is the water meter visible YES NO 2 Water meter registers when water is drawn YES NO 3 Water meter

More information

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide Concealed Twin & Triple Thermostatic Shower Valve with Diverter Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Important information 1 2. Cleaning

More information

Quartz. Digital. Concealed with adjustable height and fixed head. Quartz Digital concelaed adjustable/fixed installation instuctions page 1

Quartz. Digital. Concealed with adjustable height and fixed head. Quartz Digital concelaed adjustable/fixed installation instuctions page 1 Quartz Digital Concealed with adjustable height and fixed head The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European

More information

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING Water... 208 Gas... 210 Cassette Toilet... 211 207 WATER FAULTS Water Fault Cause Remedy Water not flowing from any tap when operated but pump runs Pump does not run Water flows from cold tap but not from

More information

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE (exposed/concealed) Shower control handles concealing plate & elbow may differ depending on Model OWNER S GUIDE Issue two INTRODUCTION This owner s guide shows

More information

Installation, Operating and Maintenance Guide

Installation, Operating and Maintenance Guide Installation, Operating and Maintenance Guide Part no. 780327-C Contents Exposed Exposed Shower Mixing Valve Wall Cover Plate (x2) Strainer (x2) Fixing Screw (x2) Hexagon Key wall Plug (x2) Green Limiter

More information

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5 CONTENTS Page Contents 1 Introduction, features and benefits 2 PART ONE Overview of the softening process Installation and operating considerations Installation layout PART TWO Installing your water softener

More information

Kiko Concealed Shower Mixing Valve KK80010CP

Kiko Concealed Shower Mixing Valve KK80010CP Kiko Concealed Shower Mixing Valve KK80010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any

More information

Thames thermostatic bar mixer with diverter Installation and operating instructions

Thames thermostatic bar mixer with diverter Installation and operating instructions Thames thermostatic bar mixer with diverter Installation and operating instructions Installers please note these instructions are to be left with the user 2180452D July 2007 CONTENTS Page Introduction

More information

SEALED THERMAL STORE

SEALED THERMAL STORE ISSUE 3 0717 INSTALLATION AND USER GUIDE ENERGYMANAGER SEALED THERMAL STORE ADVANCE APPLIANCES LTD PLEASE RETAIN AND ENSURE SERVICE RECORDS ARE KEPT UP TO DATE. SCHEMATIC DIAGRAM OF ENERYMANAGER THERMAL

More information

Alpha SolarSmart 100

Alpha SolarSmart 100 Installation and Servicing Instructions Also includes User's instructions at back Alpha SolarSmart 00 Pre-Heat Drain Back Solar System and Wall Mounted Unvented Hot Water Solar Cylinder for use with an

More information

INSTALLATION GUIDE NZ AU

INSTALLATION GUIDE NZ AU DISHWASHER DW60U6I & DW60U2I models INSTALLATION GUIDE NZ AU 1 SAFETY AND WARNINGS 100 lb 45 kg! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit

More information

Thanks for shopping with Improvements! Solar Rainmaker Automatic Plant Watering System Item #

Thanks for shopping with Improvements! Solar Rainmaker Automatic Plant Watering System Item # Thanks for shopping with Improvements! Solar Rainmaker Automatic Plant Watering System Item # 411629 To order, call 1-800-642-2112 West Chester, OH 45069 0413 If you have any questions regarding this product,

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only. EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300 Please note: Tap heads shown is for illustration purposes only. CONTENTS GUARANTEE GENERAL SAFETY INSTRUCTIONS PARTS SUPPLIED HOW TO INSTALL AFTER

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

Maintenance Tips for Tenants

Maintenance Tips for Tenants Maintenance Tips for Tenants If you experience any minor maintenance issues during your tenancy, please follow these helpful tips from our Property Maintenance team. If you need further assistance, you

More information

Thermostatic Bar Valve

Thermostatic Bar Valve 20007015000 Thermostatic Bar Valve INSTALLATION INSTRUCTIONS INSTRUCTION Thank you for purchasing a quality Bathstore product. To enjoy the full potential of your new product, please take time to read

More information

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW 3rd Fold 1st Fold NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW 2nd Fold Please tape down Please tape down Affix Stamp Installation Instructions

More information

Installation & Service Guide

Installation & Service Guide Reverse Osmosis Ontario Soft Water.ca Kitchener, Canada 519-579-0500 Installation & Service Guide Pentair 75 gpd Encapsulated Membrane System Standard System 75gpd Membrane Your New Reverse Osmosis System

More information

INSTANTANEOUS ELECTRIC SHOWER

INSTANTANEOUS ELECTRIC SHOWER GUARANTEE / SERVICE POLICY INSTANTANEOUS ELECTRIC SHOWER GUARANTEE Designa guarantee this DS3000 product for a period of two years, from date of purchase, against mechanical and electrical defects arising

More information

Installation and User Instructions

Installation and User Instructions 36005904_Dove_2005_Fitin 5/7/05 3:04 pm Page 1 DOVE 2005 Installation and User Instructions Please read and understand these instructions before starting work Heatrae Sadia Heating, Hurricane Way, Norwich,

More information