VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES
|
|
- Caren Reed
- 5 years ago
- Views:
Transcription
1 GENERAL Light controls - occupancy sensors are required Option 1: OEM Provided: OEM anti-condensate and lighting controls (on/off) are standard unless otherwise specified. Option 2: End User Provided: Light controls should be based on occupancy sensors. Store level A/S control should be set to 30% minimum off time at 75ºF/55%RH. SHIPPING WEIGHT Weight LBs
2 ELECTRICAL DATA Length Fans Per High Fans Drain Heater Defrost (1-Phase) 120 Volts 120 Volts 208 Volts 240 Volts Amps Watts Amps Watts Amps Watts Amps Watts 1 Door Door Door Door Door LIGHTING DATA OP45 Optimax Pro 24 Low 120 Volts 120 Volts Length Door Size Amps Watts Amps Watts 1 Door 31" Door 30" Door 30" Door 30" Door 30" ANTI-CONDENSATE DATA Length Individual Circuits I90 Doors ELMD, ELMH, Doors Door Frame Heated Doors Low E Doors Heated Doors Low E Doors 101-LE 120 Volts 120 Volts 120 V 120 V 120 V Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Door Size 1 Door 31" Door 30" Door 30" Door 30" Door 30" "---" indicates that this feature is not an option on this case model. Drain heater and fan motors share the same circuit (separate cycles). Electrical circuits must be properly sized to accomodate the higher current draw of the tank heater. Data listed is for Optimax Radiant and low power Optimax Pro (high power available). For other lighting options please contact your sales representative. Anti-condensate heat values for Low E doors represent a door with no heat on the glass. Listed discharge air velocity represents the average velocity at the peak of defrost. Defrost Run-off Time applies to Hot Gas Defrost only. Electric Defrost has a 0-minute run-off time. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4 F below the listed evaporator temperature. Low energy doors (no heat on the glass) do not require anti-condensate or lighting controls. Frame A/S heat is cycled off during defrost cycles. Heated doors (heat on the glass) require anti-condensate and lighting controls. Frame A/S heat is cycled off during defrost cycles. Light and A/S wattages above reflect 100% run time. To determine actual daily energy usage at 75ºF/55%RH conditions, reduce the light wattages above by 42% and reduce the A/S values above by the minimum off time.
3 GUIDELINES AND CONTROL SETTINGS DEFROST DATA Defrosts Per Day Run-Off Time Electrical Defrost Fail-Safe Termination Temp Hot Gas Defrost Fail Safe BTUH/door BTUH/door Termination Temp Superheat Set Bulb Superheat Set Bulb Evaporator Evaporator Discharge Air Discharge Air Discharge Air Velocity (FPM) Length Application Door Conventional Parallel 1 Door Frozen Heated Door Frozen Low E Door Ice Cream Heated Door Ice Cream Low E Discharge Air Velocity (FPM) Length Application Door Conventional Parallel 2-5 Door Frozen Heated Door Frozen Low E Door Ice Cream Heated Door Ice Cream Low E "---" indicates that this feature is not an option on this case model. Drain heater and fan motors share the same circuit (separate cycles). Electrical circuits must be properly sized to accomodate the higher current draw of the tank heater. Data listed is for Optimax Radiant and low power Optimax Pro (high power available). For other lighting options please contact your sales representative. Anti-condensate heat values for Low E doors represent a door with no heat on the glass. Listed discharge air velocity represents the average velocity at the peak of defrost. Defrost Run-off Time applies to Hot Gas Defrost only. Electric Defrost has a 0-minute run-off time. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4 F below the listed evaporator temperature. Low energy doors (no heat on the glass) do not require anti-condensate or lighting controls. Frame A/S heat is cycled off during defrost cycles. Heated doors (heat on the glass) require anti-condensate and lighting controls. Frame A/S heat is cycled off during defrost cycles. Light and A/S wattages above reflect 100% run time. To determine actual daily energy usage at 75ºF/55%RH conditions, reduce the light wattages above by 42% and reduce the A/S values above by the minimum off time.
4 2, 3, 4, & 5 Door (Frozen Food) DOOR OPTIONS FRONT OPTIONS FLAT FRONT (V SERIES) STANDARD SWING DOOR 2,3,4,5 - DOOR CASES 30" [76.2 cm] TANK 4" [10.0 cm] FRONT PANEL KICKPLATE
5 TOP WIRING REQUIRED 33 3/4" [85.7 cm] LOAD LIMIT 96 1/8" [244.2 cm] SHIPPING HEIGHT 93 7/8" [238.4 cm] INSTALLED HEIGHT 93 7/8" [238.4 cm] OVERALL CASE HEIGHT 89 7/8" [228.3 cm] CASE HEIGHT 72" [182.8 cm] INTERIOR HEIGHT 23 1/8" [58.7 cm] 72 1/4" [183.5 cm] VISUAL DISPLAY 79" [200.7 cm] DOOR HEIGHT 81" [205.7 cm] FRAME HEIGHT COIL PLENUM 4 1/8" [10.5 cm] 5 3/4" [14.6 cm] 26 1/2" [67.4 cm] 32 7/8" [83.5 cm] 37 1/8" [94.3 cm] 8 1/4" [21.0 cm] 11" [27.9 cm] WIRING TO THE TOP (12" X 10" X 4") 2" AIR GAP REQUIRED PIPING TO THE TOP (OPTIONAL) REAR REFRIGERATION LOCATED 9 1/4" ABOVE FINISH FLOOR 37 1/8" [94.3 cm] 32 7/8" [83.5 cm] 26 1/2" [67.3 cm] 30 1/8" [76.5 cm]** 23 1/2" [59.7 cm]* 23 1/4" [59.1 cm] 3 1/8" [7.9 cm] 7" [17.8 cm] 1 1/2" PVC DRAIN CONNECTION 31" [78.7 cm] (1 DOOR) 60" [152.4 cm] (2 DOOR) 90" [228.6 cm] (3 DOOR) 120" [304.8 cm] (4 DOOR) 150" [381.0 cm] (5 DOOR) DEFAULT REFRIGERATION 8 3/4" [22.2 cm] 1 1/2" [3.8 cm] {END} * : STUB-UP AREA. ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS. Ends add approximately 1" to case height, 1/2" to the back & 1" to the front.
ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)
GENERAL NOTES 4-foot cases consist of 2 (24") doors 8-foot cases single swing consist of 3 (32") doors 8-foot case Bi-swing consist of 4 (24") doors 12-foot cases single swing consist of 4 (36") doors
More informationONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)
GENERAL NOTES 4-foot cases consist of 2 (24") doors 8-foot cases single swing consist of 3 (32") doors 8-foot case Bi-swing consist of 4 (24") doors 12-foot cases single swing consist of 4 (36") doors
More information6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA
REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.
More informationO3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. Nose
More information6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option with this model and/or the data is not yet available. LED lights only. Maximum of 6 rows of standard output LED shelves. SHIPPING WEIGHT
More informationON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:
GENERAL "---" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 2 rows of standard output LED lighted shelves. 3rd row or
More informationON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option with this case model and/or the data is not available at this time. SHIPPING WEIGHT --- Weight ELECTRICAL DATA Fans Per High Effciency Fans
More informationOHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available at this time. LED lights only. Maximum of 4 rows of Standard Output LED lighted shelves.
More informationO5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES
GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or the data is not available yet. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. SHIPPING
More informationO5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT
GENERAL NOTES "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves.
More informationO5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---
GENERAL NOTES: "---" indicates that the feature is not an option on this case model and/or the data is not available at this time. If the case is being lined up to an ORS5DM reach-in case, a 21" front
More informationO2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)
REFERENCE NOTES FOR ENGINEERING DATA: Extended front sills are required to meat applications to maintain proper product temperature. An extended front has a minimum height of 24" on a 5" baseframe, or
More informationOIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:
REFERENCE NOTES FOR ENGINEERING DATA: "0.00" indicates that the feature is not an option on this case model LED Lights Only. Cornice lights are either standard or high output. Shelf Lights are standard
More informationO4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES
ENGINEERING REFERENCE SHEET NOTES "0.00" indicates that the feature is not an option on this case model LED Lights Only Cornice lights are either standard or high output Shelf lights are standard output
More informationORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11
R E A C H - I N D O O R M E R C H A N D I S E R I N S TA L L AT I O N & O P E R AT I O N S M A N U A L ORZ ORZH ONRZ (ALSO INCLUDES ONRZH) General Information... 2 Case Installation... 3 5 Case Connections...
More informationORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...
R E A C H - I N D O O R M E R C H A N D I S E R I N S TA L L AT I O N & O P E R AT I O N S M A N U A L ORIZ ORIZH ONRIZ (ALSO INCLUDES ONRIZH) TABLE OF CONTENTS GENERAL INFORMATION... 2 INSTALLATION &
More informationRL with INNOVATOR II No Heat Doors
RL with INNOVATOR II No Heat Doors We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding
More informationQLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR
CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat 2.43 3.43 4.35 5.40 PSC Fan 0.52 0.78 1.04 1.30 STD Fan 1.04 1.56 2.08 2.60 ECM Fan 0.50 0.75 1.00 1.25 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED
More informationInstallation & Service Manual
Installation & Service Manual NFJCX, NCJCX, NTJCX, JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to
More informationJUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases
Installation & Service Manual JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases This manual has been designed to be used in conjunction
More informationDELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT
DELI C A S E S MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK Featuring Technology COMPONENT P902077H Rev 4 1/07 WARNING MORE THAN ONE SOURCE OF ELECTRICAL SUPPLY. DISCONNECT
More informationQDV5V - 1 Door Standard (Gemtron)
CASE DATA AMPS 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 1 Anti-Sweat 0.51 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 0.98 LED Lights 0.26 All electrical data based on 115V and
More informationEXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet
EXCEL FWEGH Merchandiser Data Sheet P/N 0544870_D NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationOWIZ/OWIZV OWEZ/OWEZV
SINGLE-DECK ISLAND MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N U A L OWIZ/OWIZV OWEZ/OWEZV Table of Contents General Information... 2 Airflow & Defrost... 7 Case Installation...3-4 Cleaning
More informationP/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #
FG Technical Data Sheet NSF Certified March 2017 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the
More informationRLNIE with INNOVATOR II
Warning: Terminal block NOT for case-to-case wire connection! RLNIE with INNOVATOR II No Heat Doors NSF Certified April 2017 We reserve the right to change or revise specifications and product design in
More informationLNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #
LNG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.
More informationHANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION
HANDBOOK INSTALLATION & OPERATION O3EIF MEAT CASES Table of Contents General Information... 2 Using Casters... 3 Case Dimensions... 4 Case Operations... 5 Line Up & Trim Out... 6 Piping: Refrigeration
More informationFreedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF
Freedom Line RFLN with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready M G N F J or INNOVATOR III Doors P/N 0537768_J NSF Certified May 18 A Warning: Terminal block NOT for
More informationFreedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount
Freedom Line RFM with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready OPTIONS SHOWN: Lighted Facades I A H C J B F NSF Certified October 18 G Warning: Terminal block NOT for
More informationRM with INNOVATOR Doors
RM with INNOVATOR Doors P/N 0520868_H NSF Certified May 2017 Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in
More informationP/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #
LG Merchandisers C A F Technical Data Sheet NSF Certified February 2007 G H I I B We reserve the right to change or revise specifications and product design in connection with any feature of our products.
More informationFreedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.
with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready K E I P/N 0541253_J NSF Certified January 201 F L Warning: Terminal block NOT for case-to-case wire connection! J G I A
More informationP/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet
Excel FWEGH-L Merchandiser Data Sheet P/N 0544871_D NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationExcel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet
Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationEXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet
EXCEL FWEGH-L Merchandiser Data Sheet P/N 0544871_F NSF Certifi ed March 2017 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National
More informationFreedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount
Freedom Line merchandisers are top mount refrigeration ready Freedom Line RFMN with INNOVATOR Doors NSF Certified January 18 OPTIONS SHOWN: Lighted Facades Warning: Terminal block NOT for case-to-case
More informationF-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #
G C A F-L Technical Data Sheet P/N 0523702_C NSF Certified March 2017 H B E F J We reserve the right to change or revise specifications and product design in connection with any feature of our products.
More informationFG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #
FG-L Technical Data Sheet P/N 0523821_C A NSF Certified March 2017 G H C K B E We reserve the right to change or revise specifications and product design in connection with any feature of our products.
More informationField Top Mounted Condensing Unit
Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the
More informationFIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet
FIG-L Technical Data Sheet P/N 0523825_F NSF Certified January 2018 H C A L B F J G K M We reserve the right to change or revise specifications and product design in connection with any feature of our
More informationFWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #
G FWEL Technical Data Sheet NSF Certified January 2018 E D C H B A F J We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes
More informationM1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #
Merchandisers C F M1GLE-93 Technical Data Sheet P/N 0405077_G NSF Certified July 2010 A E We reserve the right to change or revise specifications and product design in connection with any feature of our
More informationInstallation & Service Manual
Installation & Service Manual NFJGCX, NCJGCX, NTJGCX, NFMJGCX, NFJGECX, NCJGECX GLASS FRONT JUMBO ISLAND FROZEN FOOD/ICE CREAM/ MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display
More informationP/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet
Excel FWGH-L Merchandiser Data Sheet NSF Certified May 2016 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation)
More informationFIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N
H C J A F E FIG Technical Data Sheet NSF Certified March 2017 G B I We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes
More informationFWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.
E C D E F J G I FWG Technical Data Sheet NSF Certified June 2016 DOE 2012 Energy Efficiency Compliant A We reserve the right to change or revise specifications and product design in connection with any
More informationEngineering Plan Views
LifeLine Premier RL with INNOVATOR Doors or INNOVATOR III Doors P/N 0520875_J NS Certified January 2018 OPTIONS SHOWN: Arch acade Dry Goods Storage Bump Out Partitions Warning: Terminal block NOT for case-to-case
More informationDELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT
DELI C A S E S MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK COMPONENT P05971K Rev. 8 7/04 Welcome to the ORIGIN display case family. We re very pleased you joined us. This installation
More informationFG-L Technical Data Sheet
FG-L Technical Data Sheet P/N 0523821_B A NSF Certified March 2016 G DOE 2012 Energy Efficiency Compliant H C K B E We reserve the right to change or revise specifications and product design in connection
More informationNFW, NCW, NFWG, NCWG, NFWE, NCWE
Installation & Service Manual WIDE ISLAND FROZEN FOOD & ICE CREAM MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General (UL/NSF)
More informationP/N _F NSF Certified June 2010
G C A F E FN Technical Data Sheet P/N 0465898_F NSF Certified June 2010 B D We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such
More informationRLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018
RLTIM with INNOVATOR We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes,
More informationInstallation & Service Manual
Installation & Service Manual NMFG Shown NMF / NMFG SINGLE DECK FROZEN MEAT MERCHANDISERS Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General
More informationFWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #
FWG C D E F J Technical Data Sheet NSF Certified December 2008 E G I A We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes
More informationFWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish
FWG-L Technical Data Sheet P/N 0523827_D NSF Certified May 2016 DOE 20 Energy Efficiency Compliant We reserve the right to change or revise specifications and product design in connection with any feature
More informationRLT with INNOVATOR Doors
Refrigeration and electrical connections are on top. Overhead piping and electrical circuits are required. RLT with INNOVATOR Doors Technical Data Sheet P/N 0445823_K NSF Certified August 2013 We reserve
More informationL6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases
Installation & Service Manual L6FA MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation &
More informationSERVICING SUPERMARKET REFRIGERATION EQUIPMENT By: Kenneth S. Franklin National Service Manager Hussmann Refrigeration, Inc.
INTRODUCTION SERVICING SUPERMARKET REFRIGERATION EQUIPMENT The 1960s and early 1970s brought about a revolution in the merchandising of food products. With the growth and extension of suburban areas has
More informationREAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT
REAR LOAD DAIRY C A S E S M O D E L : O 5 D R & O 5 D R H INSTALLATION & OPERATION HANDBOOK P056170D COMPONENT Rev. 13 11/10 Welcome to the Hill PHOENIX display case family. We re very pleased you joined
More informationRLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018
RLNI with INNOVATOR Doors or Serial Plate INNOVATOR III Doors NS Certified January 2018 We reserve the right to change or revise specifications and product design in connection with any feature of our
More informationP1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016
Technical Data Sheet NSF Certified October 2016 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the
More informationScotsman Technical Training. CU50 Cube Ice Machine
Scotsman Technical Training CU50 Cube Ice Machine Major Topics Overview Installation Start Up Sequence of Operation Maintenance Diagnostics Service Procedures Models Two Base Models Gravity Drain Pump
More informationL3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases
Installation & Service Manual THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases This manual has been designed to be used in conjunction with the General Installation & Service
More informationREFRIGERATION. Standard Features & Accessories. Model Options. All models include. FGIM515/FPIM515 Professional Door Panel (PIDP15)
Standard Features & Accessories REFRIGERATION All models include Produces up to 65 lbs. of clear ice per day 26 lb. capacity ice bin 1 x 1-1/8 x 1-1/4 cube size LED light LED control panel o Power On/Off
More informationFreedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.
Freedom Line RFMNS with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready H B F P/N 054156_J NSF Certified January 01 C I We reserve the right to change or revise specifications
More informationISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT
ISLAND PRODUCE C A S E S MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK COMPONENT P054956H Rev. 7 11/06 Welcome to the ORIGIN 2 display case family. We re very pleased you joined us. This
More informationNosing Heater. Return Grill Heater
Insight standard field electrical connections are at the bottom of the merchandiser Insight IM1SL-L Merchandiser Data Sheet NSF Certifi ed September 2017 Fan* Defrost Heater (Below coil)* Coil* Nosing
More informationSECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS
SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES After studying this unit, the reader should be able to Explain what conditions will cause the evaporator pressure
More informationSECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES
SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES After studying this unit, the reader should be able to Explain what conditions will cause the evaporator pressure
More informationINSTALLATION & OPERATION MANUAL
Part No. 31E11044 Date: 4/11/11 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QFGCEID-A, QFGTD-A QNGCEID-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR
More informationINSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE
Part No. 31E10015 Date: 3/2/10 5201 Transport Boulevard Columbus, GA 31907 706-568-1514 INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT
More informationDELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT
DELI C A S E S MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK COMPONENT P052392H Rev. 14 05/09 Welcome to the Hill PHOENIX display case family. We re very pleased you joined us. This installation
More information2 Building Type. 3 Trade Ally/Contractor Information. Refrigeration Rebate Worksheet. Retrofit New Construction
Refrigeration Rebate Worksheet Before you start Instructions: Complete all relevant information for your project. Include with completed final application package. All rebates are paid per unit and are
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationREFRIGERATION BASICS FOR HOTELS COMMON EFFICIENCY MEASURES
REFRIGERATION BASICS FOR HOTELS COMMON EFFICIENCY MEASURES February 9, 2017 Emre Schveighoffer, President Agenda Brief overview of refrigeration systems found in hotels Typical issues that seem to happen
More informationMCR & MCR SERIES Roll-in & Pass-Thru Blast Chillers
ITEM NO. PROJECT LOCATION DATE QTY. MCR-33-101 FEATURES Full-length evaporator coil and vertical fan tower provide evenly distributed cooling. MCR-33-101 & MCR-33-102 SERIES Roll-in & Pass-Thru Blast Chillers
More information3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT
3-DECK ISLAND PRODUCE C A S E S M O D E L S : O 3 I P & O 3 I P B INSTALLATION & OPERATION HANDBOOK COMPONENT P053096D Rev. 9 11/10 Welcome to the Hill PHOENIX display case family. We re very pleased
More informationJBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0
Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility
More informationSpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.
Microwave FPMV189K F Product Dimensions Height 17-1/16" Width 29-29/32" Depth 16-3/4" More Easy-To-Use Features One-Touch Keep Warm Setting Keep food warm until everything and everyone is ready. Real Stainless
More informationBottom Mount Refrigerator---Technical Information
Bottom Mount Refrigerator---Technical Information WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operation. Failure to do so can result in death
More informationUnico Training. Welcome to Unico!
Welcome to Unico! UNICO Inc Who are we? Unico Inc. is a family owned and operated manufacturing company. Unico Inc. is the largest manufacturer of SDHV systems in the world. Unico Inc. is manufactured
More informationInstallation & Operation Manual. Reach-In Display Case. KW-IOM-2149 July 2016 Part No. 31E02149
Installation & Operation Manual KW-IOM-2149 July 2016 Part No. 31E02149 Contents Reach-In Display Case Introduction General Information 3 Plan and Cross Views 5 Case Data 7 Case Installation 18 Electrical
More informationSCN60 Residential Nugget Ice Machine
SCN60 Residential Nugget Ice Machine SCN60 Nugget Ice Nugget Ice What it isn t: Ice frozen in a mold What it is: A chewable ice, formed continuously by forcing soft ice thru tapered holes. Components Compared
More informationRVZC30 (and BB/T/TBB/WA), RVZP30 (and BB/T/TBB/WA), RVC24
2 TABLE OF CONTENTS INTRODUCTION... 4 DELIVERY INSPECTION... 4 PACKAGING... 4 LOCATION... 4 Figure 1: Case label information... 5 INSTALLATION... 6 Leveling... 6 Figure 2: Leveling cases prior to joining...
More informationHot Water Heating Systems
Hot Water Heating Systems Find out more at www.greeonline.com Key Wide Range of Operation Conditions Heating -26 C 46 C Features The Ultra Hot Water system is specifically designed to be flexible in its
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationUnico Training. Class for R E Michel Salesmen
Class for R E Michel Salesmen Outlet (UPC-56B) Sound Attenuator (UPC-26C) Elbow Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling Modules (MC2430, MC3642,
More informationDue to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.
Bottom Mount Refrigerator Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTION
More informationINSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers
S elf-contained Freezers INSTALLATION and OPERATING INSTRUCTIONS for Series ZERO ZONE Zero Zone, Inc. 110 N. Oakridge Dr. North Prairie, WI 53153-9792 1-800-247-4496 FAX: 1-414-392-6450 www.zero-zone.com
More informationLo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.
bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationMULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents
MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL O5Z Table of Contents Electrical Data & Case Dimensions... 2 3 General Information... 4 Imporant Notices... 5 Line-Up... 6 7 Trim Out....
More informationTechnical Manual Binair Monobloc Heat Pump
Technical Manual Binair Monobloc Heat Pump MODEL BINAIR12 Introduction Disassembly of the machine must be carried out by any professional or any special agency assigned by us. All operation and maintenance
More informationPSB42YGX GE Profile 42" Built-In Stainless Side-By-Side Refrigerator with Dispenser
imensions and Installation Information Product Clearances These refrigerators are equipped with a 2 position door stop. The factory set 130 door swing can be adjusted to 90 if clearance to adjacent cabinets
More informationCAUTION. No-Load Performance, Controls in Normal Position
Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationSmall Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.
Small Commercial Business Energy Audits Recognizing and addressing the special requirements of the small business market segment. Class 7 Class 7: Refrigeration Fundamentals The Vapor-compression cycle
More informationKeep your electricity bill cool this summer
Keep your electricity bill cool this summer The summer months are notorious not only for high temperatures, but also for high electricity use. There are a number of things you can do to conserve electricity
More informationAG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL
AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL Arrowsmith and Grant Refrigeration Manufacturers & suppliers of prestige home refrigeration equipment. ABN: 64 007 296 586 28-30 Marni St Dandenong
More information