Rainwater - Management for the environment and nature protection
|
|
- Nancy Hodges
- 5 years ago
- Views:
Transcription
1 RAINWATER Rainwater - Management for the environment and nature protection
2 Flow Control Type AT Type A Type WAB-UCY Flow regulators have the task of restricting the pass forward flow from the storm water retention system to a preset value. ALPHEU Type AT The ALPHEU Type AT flow control system has been designed for semidry or dry installation in the flow control shaft. In this case, the system operates independently without external energy. In dry weather, the water flows unhindered through the throttle. If the water level rises above a certain level during rain, the float will be activated and starts the precise regulation. An automatic regeneration system is integrated for blockages during flow regulation work. Vortex regulator Type WAB-UCY The Vortex flow regulator consists of a cyclone like robust stainless steel construction with no moving parts. The water flows tangentially into the throttle. This leads to the formation of an air-filled vortex core. This vortex has a braking effect without physically obstructing the flow opening and therefore guarantees a predefined maximum capacity. Float operated throttle valve Type WD The float operated throttle valve has been designed for a wet installation in the flow control shaft. During rain activity the float will rise with the water level and causes the gate plate to close progressively the throttle opening. By reducing the discharge opening, the WD starts its throttling action and keeps the desired flow rate at a maximum water level constant. ALPHEU Type A and Type AA The ALPHEU Type A and Type AA flow control systems have been designed for a wet installation in the flow control shaft. Both systems work by means of a pressure bell housing which regulates the flow quantity using an interior float. Vortex regulator Type WAB-CE/V The vertical vortex regulator is a wet installed unit and there is no need of a separate throttle manhole. It consists of a vertical vortex body placed on a plug-in board and is particularly suitable for the limitation of rainwater. With a pull rod/bar, the device can be pulled completely up to remove any possible blockages. Advantages mechanical flow regulators TÜV-approved vertical Q/H- characteristic (ALPHEU) Automatic operation without any external power Product variations for dry, semi-dry and wet installation Automatic deblocking (AT, AA) High-quality, robust stainless steel construction Adapter options: Circular chamber, emergency bypass and emergency overflow.
3 Flow Control Type EGAR Type D Modern management of the sewer system requires reliable flow con trol systems. The increasing requirements on flow control call for flexible control strategies and intelligent, electrical solutions such as remote operation, data transfer and processing to modern media. Electrical flow regulator Type EGAR The electrical flow regulator type EGAR has been developed precisely for these requirements. A penstock for flow regulation is controlled by an electrical actuator. The water level recorded from a level measurement is directly involved in the calculation of the gate opening by a discharge formula stored in the PLC. The system offers infinitely adjustable controlled flow amount via an operating device and automatic deblocking. In the event of backflow, the downstream level is included in the discharge formula and depending on the control strategy, the throttle penstock continues to open and keeps the flow rate approximately constant or the penstock closes to protect the sewer system. The system can easily be retrofitted into existing structures, offers a high operation safety and can be connected to remote control and transfer systems. MID Flow control Type D The electrical flow control type D has been developed for high requirements on flow control accuracy. The flow will be registered by magneticinductive flow meters (MID) for semiand fulfilled pipelines. The registered flow rate is compared with the set flow rate by the electronic control penstock. If the actual value deviates from the set flow rate, the control penstock is moved to the corresponding position. The system offers infinitely adjustable controlled flow amount via an operating device. Furthermore, the flow control unit has an automatic deblocking system. The backflow detection ensures that, depending on the control strategy, the set flow rate is maintained as far as possible or the control penstock will be closed to protect the sewer system. Together with the remote control connection to a superior system, this flow control system is a modern and intelligent solution, installed into a separate dry throttle shaft. Advantages electrical flow control Reliable and constant flow control with vertical Q/Hcharacteristic Multiple control strategies programmable Infinite adjustment of the flow rate via operation device Automatic deblocking system Back flow detection and integration in control strategy Remote control connection possibility Dry, semidry and wet installation possible with type EGAR High-quality, robust stainless steel construction Control unit EGAR in a protective cabinet D Flow control
4 Flushing system A storm tank before (left) and after (right) rinsing with a flushing system. Easy cleaning of the sole with the vacuum flushing system. Type MF In any storm water retention system, sediments in the form of sludge or settled solids will build up over time on the tank floor. Incoming organic material also results in consider able odor nuisance. In order to effectively clean up the retention tanks, BIOGET has developed flushing systems which can be used with or without electrical energy. Vacuum flushing system Type MF Once the water level in a tank or a sewer reaches a certain level, a vacuum pump switches on automatically and fills the flushing chamber up with water. As soon as the basin or the sewer has been emptied, the sediments remain on the tank floor. Now the flushing process starts automatically by filling the tank or sewer with one surge using the water from the flushing chamber. This powerful flushing action means that any deposited sediments are carried away and the tank floor is clean again. Flushing system principle Here the principle of the flushing process is demonstrated, using vacuum technology. Incoming mixed water is used to fill the flushing chamber up using a vacuum pump. This starts even with a minimal filling of the tank, respectively with each partial filling event. Once the tank or sewer is empty, the flushing sequence starts automatically. A powerful water surge rinses the floor clean, without any moving parts in the tank. Flushing of a rectangular tank Flushing of a sewer system Advantages flushing system with vacuum technology No moving parts in contact with waste water (no risk of blockage) Efficient cleaning with a water head of up to 7 m Cleaning action using mixed or rain water from the tank uitable for all kind of tank shapes, flexible system Flushing of a circular tank Minimal maintenance - no man entry required for maintenance Optimal flushing result, even on very long lanes and large circular tanks afety and hygienic advantages.
5 Flushing system Flushing gate in a storm tank in action Type K Gate flushing system Type K An established method of surge cleaning is the technology with flushing gates developed by BIOGET. In this case, control can either take place electronically or by using float technology. The flushing chamber is filled whenever water is in the tank or sewer. As soon as the tank is empty, the flushing gates will open subsequently and the flushing wave enters the sewer or tank with a very high sweeping force. Channel flushing gate Type CF torm water catchment channels create sediments during storm events. If these long channel sections are not cleaned, the potential for blockages is increased and odor nuisance will occur due to septicity. The channel flushing gate is an ideal solution to solve this problem. Once a flushing is required, the gate will be operated electro-hydraulically in low position. The upstream channel water fills the channel behind the plate. Once filled, the gate will be opened and the flushing sequence starts automatically. Advantages flushing with channel flushing gate Channel flushing in large and long channels Flushing of a tank with gates Advantages flushing system with gates technology Efficient cleaning with a water head of up to 3 m Cleaning action using mixed or rain water from the tank Delayed closing of the gate using damping function (optional) Channel flushing gate in upper position Channel flushing gate in low position Periodic channel management and flushing Gate is in open position out of the cross-section Robust stainless steel construction Low maintenance izes from DN , larger possible. Excellent locking technology and very fast opening of the gate Low maintenance requirement and low energy consumption.
6 Coarse solid retention Type A Type LTW During periods of heavy rainfall, both the water quantity can lead to problems and coarse solids can be difficult to deal with. Hygiene articles or other waste at inlet locations to receiving waterways can result in unwanted pollution, which can even be environmentally damaging. creening equipment or lamella baffles from BIOGET can provide a solution. Floating scum baffle Type WTW The floating scum baffle consists of one or multiple balanced floating bodies up to 6000 mm in total length. Due to the specific arrangement of the floating body, floating matters are effectively retained, even at lowest rising water level. torm water screen Type A The BIOGET storm screen ensures high performance screening during periods of heavy rainfall. The solid retention system is installed at overflow weirs and can easy be retrofitted in existing structures. The waste water flows through the perforated screen basket, which is arranged as a semicircle section. The screen basket is fully automatically cleaned during operation. The system retains floating matter and sediments efficient and protects the environment from pollution. Advantages storm water screen Ideal solid retention by means of two-dimensional screening Efficient and continuous automatic screen cleaning Lamella baffle Type LTW The BIOGET lamella baffle is fitted upstream of and below an overflow weir and ensures that sediments floating on the water surface are retained. This means that there are no horizontal flows with suction effect on the surface. The system can be retrofitted easily in existing structures and also adapted individually. There is even a solution suitable for circular structures. Forwarding of extracted screening material to WWTP Advantages floating scum baffles Effective retention of floating solids by floating baffle Ideal for large and fluctuating water levels Vertical and radial versions possibl Easy retrofitting in existing overflow structures Advantages lamella baffles Effective floating retention of floating solids Operation without external energy Installation possible through very small access openings Circular version available Low maintenance
7 Debris retention system Grit trap Type GEMO Wastewater sewers always carry coarse solids such as grit, gravel or stones. These sedimentary materials cause damage to machines and mechanical parts which are installed in wastewater treatment facilities. It makes sense to collect the sedimentary material automatically and to repeatedly remove it from the sewers. BIOGET has developed an extremely effective grit trap for this purpose. Grit trap Type GEMO The grit trap is placed in a shaft without any fixed installed parts. The passing heavier particles sink into the grit trap basket. Moreover, the sedimentary material is aerated and circulated due to holes in the bottom of the basket, while sedimentation of suspended solids is prevented. Following the filling degree, the grit trap can be lifted by means of suitable lifting gear, emptied and then placed back into the shaft. Aeration of the grit trap is not required for surface and road water drainage. GEMO operating in the shaft Grit trap in circular version Advantages grit trap imple collection and removal of grit imple and inexpensive fitting No technical installations in the grit trap shaft required Compact and robust implementation in stainless steel Fast emptying even during operation Grit trap in rectangular version GEMO during emptying Extremely low maintenance
8 RAINWATER Innovative concepts for environmental technology Copyright BIOGET AG BIOGET AG iemensstraße Taunusstein Telefon: / info@biogest.com
Practical Solutions for Combined Sewer Overflow Control. Engineering Healthy Waterways
Practical Solutions for Combined Sewer Overflow Control Engineering Healthy Waterways PROCESS OVERVIEW 4 LEVELS OF TREATMENT 1. Screening (Coarse Screening (>1 MM), Fine Screening (
More informationSedimentation. Photo Credit: Virginia Department of Health
Sedimentation. Photo Credit: Virginia Department of Health Objective In this lesson we will answer the following questions: How does sedimentation fit into the water treatment process? What zones are present
More informationHUBER Grit Separation Systems
WASTE WATER Solutions HUBER Grit Separation Systems Reliable Complete Plants for separation of screenings and grit A range of grit trap systems for separation of mineral particles The optimally suitable
More informationHUBER Grit Separation Systems
WASTE WATER Solutions HUBER Grit Separation Systems Reliable Complete Plants for separation of screenings and grit A range of grit trap systems for separation of mineral particles The optimally suitable
More informationHUBER Grit Separation Systems
WASTE WATER Solutions HUBER Grit Separation Systems Reliable Complete Plants for separation of screenings and grit A range of grit trap systems for separation of mineral particles The optimally suitable
More informationSAVI MultiRake Perforated Plate Screen
HEADWORKS SCREENS FSM Filterscreen FRSIII Perforated Plate Belt Screen Highest Screenings Capture Ratio at 85% as verified by ThompsonRPM testing. Self-adjusting cleaning brush mechanism eliminates manual
More informationOPERATION & MAINTENANCE
OPERATION & MAINTENANCE Nutrient Separating Baffle Box A Complete Stormwater Filtration System TM Bio Clean Environmental Services, Inc. www.biocleanenvironmental.com P.O. Box 869 P 760-433-7640 Oceanside,
More informationHEADWORKS PERFORATED PLATE FILTER SCREEN ROTARY DRUM SCREEN IN CHANNEL PERFORATED DRUM SCREEN
HEADWORKS PERFORATED PLATE FILTER SCREEN The Filter Screen eliminates operational disruptions caused by fibrous and other inorganic material. Depending on the perforated panel, the screening capture rate
More informationPretreatment Applications. John Meunier Products and Solutions WATER TECHNOLOGIES
Pretreatment Applications John Meunier Products and Solutions WATER TECHNOLOGIES 1 A long tradition in excellence John Meunier products have been serving North American municipalities and industries since
More informationPretreatment. Complete Line of John Meunier Products and Solutions WATER TECHNOLOGIES
Pretreatment Complete Line of John Meunier Products and Solutions WATER TECHNOLOGIES 1 A long tradition in excellence John Meunier products have been serving North American municipalities and industries
More informationDOUBLE AND SINGLE ENTRY DRUM SCREEN ADVANCED WATER SCREENING TECHNOLOGY
ENERGY DRUM SCREENS ADVANCED WATER SCREENING TECHNOLOGY In-to-out flow pattern eliminates screen bypassing High debris handling capacities Can operate with high headloss without tripping Option of a Fish
More informationEnvironmental Protection
Environmental Protection SEWER APPURTANCES -By Er. Md. Shahid Arshad Assistant Professor Civil Engg. Deptt., ACET Manhole Manholes are masonry or R.C.C. chamber constructed at suitable intervals along
More informationLIQUID/SOLID SEPARATION
LIQUID/SOLID SEPARATION Headworks Screens Screening Systems Grit & Solids Management HEADWORKS SCREENS SAVI Flo-MultiRake Medium-Duty GVB- Coarse Bar Screen GVF- Fine Bar Screen GVS- Perforated Media Screen
More informationEIMCO Clarifiers... Customized Designs to Match Unique Specifications Most standard or special sedimentation/clarification requirements can be accommo
EIMCO Custom Clarifiers Efficient Clarification and Sedimentation of Wastewater EIMCO Clarifiers... Customized Designs to Match Unique Specifications Most standard or special sedimentation/clarification
More informationOPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS
OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden
More informationJacopa Tipping Bucket
Key Features & Benefits: Can be fitted in new design or retrofitted into existing tanks. Can be installed in attenuation sewers. Small units can be used to clean static CSO screens. Automatically tips
More informationTel Group
www.wamechsi.com Tel +27 12 808 0682 sales@wamechsi.com VERTICAL SHAFT, LOW SPEED, AERATORS Technical Specifications Vertical shaft, low speed aerators are ideal for the bacterial oxidization of effluent
More informationScreening and Grit Removal presented by Doug McCord EnQuip.com
Screening and Grit Removal presented by Doug McCord EnQuip.com KEY COMPONENTS IN A SEPTAGE RECEIVING FACILITY ACME SEPTAGE CO. LIQUID PROCESS 5% SOLIDS PROCESS 95% PUMP SCREEN GRIT REMOVAL (optional) GREASE
More informationEMD - Rotary Drum Screens
EMD - Rotary Drum Screens Pre-treatment of Domestic & Municipal Waste Waters Solids Recovery & Processing from Industrial Effluents MBR Membrane Bioreactor Inlet Screening Storm Overflows and Sea Outfalls
More informationContent. 1 Basics. 2 Detailed Information on different types of Vacuum technologies. Vacuum sanitary installations. Vacuum sewer systems
Vacuum Technology - collection and transport of sewage by means of low pressure Christine Werner, Florian Klingel, Ulrike Mosel, Sebastian Hass Deutsche Gesellschaft für Technische Zusammenarbeit (GTZ)
More informationJacopa Screenings Transfer Options
Jacopa Effective Screening of Municipal Wastewater Flows Contents: Launder TSC Transfer (Shaftless) Screenings Conveyor TAC Transfer (Shafted) Screenings Conveyor Double Screw Transfer Screenings Conveyors
More informationColumbus Southerly WWTP New Headworks June Presented by: Chad Dunn, PE Malcolm Pirnie, Inc.
COLUMBUS SOUTHERLY SOUTHERLY WWTP NEW WWTP HEADWORKS NEW HEADWORKS CONTRACTS S65, S67, & S73 Columbus Southerly WWTP New Headworks June 2010 Presented by: Chad Dunn, PE Malcolm Pirnie, Inc. New Headworks
More informationHopwood Motorway Service Area, Worcestershire
Hopwood Motorway Service Area, Worcestershire SuDS used Grass filter strip Stone collector trench Spillage basin Grass swale Balancing ponds Wetland ditch Wetland treatment Sub-surface collector trench
More informationACO Marine Advanced wastewater solutions for the marine and offshore market
ACO Marine Advanced wastewater solutions for the marine and offshore market ACO Marine environmental solutions for the marine and offshore market ACO Marine is a member of the international ACO Group
More informationInspection and Maintenance of Stormwater Best Management Practices
FAC T S H E E T Inspection and Maintenance of Stormwater Best Management Practices is a general term that refers to vegetated stormwater best management practices (BMPs) that temporarily store rainwater
More informationMANUAL OF DESIGN, INSTALLATION, AND MAINTENANCE REQUIREMENTS FOR STORMWATER MANAGEMENT PLANS
MANUAL OF DESIGN, INSTALLATION, AND MAINTENANCE REQUIREMENTS FOR STORMWATER MANAGEMENT PLANS May 2007 SECTION 1 Responsibility of Applicant TABLE OF CONTENTS A. Stormwater Management Plan Required Information
More informationRotaCut Inline Grinders True protection of downstream pumps and equipment.
ENGINEERED TO WORK PRECISION INLINE GRINDING & SOLIDS SEPARATION RotaCut Inline Grinders True protection of downstream pumps and equipment. Industry Agriculture Mining Biogas Agriculture Wastewater RotaCut
More informationVenturi wet scrubber VDN Separation of combustible, explosive, humid and adhesive dusts
Venturi wet scrubber VDN Separation of combustible, explosive, humid and adhesive dusts Compact wet scrubber VDN-E with detachable disposal bin Function For combustible, explosive, humid and adhesive dusts
More informationJIWET technical report. 8. Rotary Screen
8.Rotary Screen N. Horie 1, M. Kabata 2, H.Sano 3 and S.Simozeki 4 Director 1, Chief Resercher 2, Senior Resercher 3 and Resercher 4 First Research Department Japan Institute of Wastewater Engineering
More information88MLV Series Open Channel Modular UV Systems
88MLV Series Open Channel Modular UV Systems Series description Modular 88MLV series is based on up-to-date high output amalgam lamps and designed for installation into open channels for wastewater disinfection.
More informationA Low-Flow Self-Cleaning Drainage System for Fish Rearing Tanks
The University of Maine DigitalCommons@UMaine Marine Sciences Faculty Scholarship School of Marine Sciences 4-1-1998 A Low-Flow Self-Cleaning Drainage System for Fish Rearing Tanks D. S. Hagopian John
More informationInlet Filters Catch Basin Inserts Operation and Maintenance Manual
Inlet Filters Catch Basin Inserts Operation and Maintenance Manual Version 1.0 Suntree Technologies, Inc 798 Clearlake Road, Suite 2 Cocoa Florida 32922 321.637.7552 www.suntreetech.com info@suntreetech.com
More informationI. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System
BMP Train kitchen staff and other employees about how they can help ensure BMPs are implemented. Post "No Grease" signs above sinks and on the front of dishwashers. I. Best Management Practices (BMPs)
More informationADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES
ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES INTRODUCTION Wastes like cooking oil, grease and food solids are produced by food outlets and services throughout the Timaru District every day. When this
More informationStorm Water Management Products
Storm Water Management Products Total Storm Water Management Solutions All interchangeable products Snaps into place from street level No moving parts No special tools or brackets Tough, light weight,
More informationStandard for Bioretention Systems
New Jersey Stormwater Best Management Practices Manual February 2004 http://www.state.nj.us/dep/watershedmgt/bmpmanualfeb2004.htm Definition Purpose C H A P T E R 9. 1 Standard for Bioretention Systems
More informationAppendix D - Technical Design Criteria for BMPs
Appendix D - Technical Design Criteria for BMPs City of Wayzata Page 3 On-site infiltration features Definitions and Scope: Infiltration facilities are constructed basins or depressions located in permeable
More informationRenewable Energy 101
Renewable Energy 101 WATER IS A PRECIOUS RESOURCE! LESS THAN 1% OF ALL WATER ON THE EARTH CAN BE USED BY PEOPLE! THAT IS WHY IT S MORE IMPORTANT THAN EVER TO USE OUR WATER WISELY AND NOT WASTE IT. IN ADDITION,
More informationVERSA Rotary Drum Screens
NEW UNIVERSAL SCREEN VERSA Rotary Drum Screens Suitable to be installed in each channel and in every condition Pre-treatment of Domestic & Municipal Waste Waters Solids Recovery & Processing from Industrial
More informationRaingardens and Bioretention Tree Pits MAINTENANCE PLAN. EXAMPLE June 2008
Raingardens and Bioretention Tree Pits MAINTENANCE PLAN EXAMPLE June 2008 Table of Contents 1 RAINGARDEN AND BIORETENTION TREE PIT FUNCTIONS... 2 2 MINIMISING LONGTERM MAINTENANCE... 4 2.1 Filter media...
More informationOPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES
OPERATIONS & MAINTENANCE MANUAL FOR POST CONSTRUCTION MEASURES THE CARMONY BUILDING PARAGON REALTY NORTH GREEN STREET BROWNSBURG, HENDRICKS COUNTY INDIANA 8365 Keystone Crossing, Suite 201 Indianapolis,
More informationWhat is Rainwater harvesting?
System of collection rainwater and conserving for future needs has traditionally been practiced in India. The traditional systems were time-tested wisdom of not only appropriate technology of Rainwater
More informationOPERATION & MAINTENANCE
Curb Inlet Filter OPERATION & MAINTENANCE Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058 www.biocleanenvironmental.com p: 760.433.7640 f: 760.433.3176 OPERATION & MAINTENANCE
More informationSustainable Urban Drainage Systems. Diederik Rousseau Tineke Hooijmans
Sustainable Urban Drainage Systems Diederik Rousseau Tineke Hooijmans Contents Presentation Water cycle links The issues facing stormwater management Conventional approach and drawbacks SUDS triangle and
More informationSMALLBORE PIPEWORK GREASE TRAPS SEPTIC TANKS / CESS PITS INTERCEPTORS
SMALLBORE PIPEWORK SEPTIC TANKS / CESS PITS GREASE TRAPS INTERCEPTORS COUNCIL MAIN GULLIES GUTTERS AND DOWNPIPES These are the main parts of your drainage system. There are two lines; the foul line and
More informationTechnical Memorandum. 1 Summary Findings and Conclusions. SMCSD Headworks, Primary and Secondary Treatment Pre-Design
Technical Memorandum Water andenvironment SMCSD Headworks, Primary and Secondary Treatment Pre-Design Subject: Prepared For: Prepared by: Reviewed by: SMCSD Dennis Gellerman Steve Clary, Mark Takemoto
More informationHow do I effectively reduce the operating costs of my car wash?
How do I effectively reduce the operating costs of my car wash? With sustainable water treatment solutions. www.washtec.com INTRO INTRO Who offers the solutions my customers expect from me? WashTec gives
More informationSedimentation Equipment. Inclined Plate Settlers
Sedimentation Equipment www.metsominerals.com Inclined Plate Settlers The Lamella Principle The two basic criteria for gravity settling equipment are good clarity of the over flow liquid and maximum density
More informationTown of Essex Small Site Erosion Control Guide
Town of Essex Small Site Erosion Control Guide Why do we need to protect against erosion? Water Quality: Erosion and the transport of sediment and pollutants impacts the water quality of nearby streams
More informationOwners Instruction Manual
Owners Instruction Manual Ultra Clear WASTE WATER TREATMENT SYSTEMS Domestic Single Tank Systems Contents Page Foreword 1 Description & Function Primary Treatment Aerobic Treatment Sludge Return Surge
More informationThe Pressure Sewer System Owners Guide
The Pressure Sewer System Owners Guide Environment One Corporation A Precision Castparts Company The Pressure Sewer System * Your grinder pump station may be different than model shown. A pressure sewer
More informationAppendix G. Detailed Design
Appendix G Detailed Design G1: Construction details Construction detail drawings usually include important details and specifications for required project design elements. This section provides information
More informationPost Construction BMPs
Post Construction BMPs Why are Post Construction BMPs important? With increased development brings the increase of impervious cover Parking lots, rooftops, driveways Storm water runoff volume increases
More informationC.1 Operational Information Requirements
C.1 Operational Information Requirements 1.1 The Existing Galway Waste Water Works The Galway City sewer network has expanded with the development of the city, and the oldest sewers can be found in city
More information5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS
5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS Low Impact Development (LID) requires a shift in stormwater management away from conveying runoff to a small number of downstream points through hydraulically
More informationHuber Technology Superior craftsmanship since 1872
Huber Technology Superior craftsmanship since 1872 The Quality Company Worldwide Deep Channel Screens Step Screen SSL, SSF and SSV Inclination 70 to 75 (SSV), 40 to 53 (SSF), 45 (SSL) Discharge height
More informationHUBER Grit Treatment Systems
WASTE WATER Solutions HUBER Grit Treatment Systems Well-proven technology High separation efficiency High minerals yield Reduced disposal costs Grit Treatment Grit and mineral material from wastewater
More informationPlanning, Design, and Construction of Green Infrastructure.
Planning, Design, and Construction of Green Infrastructure www.water.rutgers.edu What is Green Infrastructure? an approach to stormwater management that is costeffective, sustainable, and environmentally
More information4. CONCEPT PLAN DEVELOPMENT
4. CONCEPT PLAN DEVELOPMENT Concept Plan Step 1: Identify Site Constraints and Opportunities Review the existing site to identify constraints and opportunities for GI Practices to meet the RRv. Constraints
More informationHouse Drainage System. Building Utility & Services
House Drainage System Building Utility & Services Syllabus House Drainage: principles of house drainage, pipes and traps, Classification of traps: nahni trap, interception trap, grease-trap, sanitary fittings,
More informationSolids Handling and Reduction Choices for Wastewater Applications
Solids Handling and Reduction Choices for Wastewater Applications Summary of Presentation 1. Why do we need Solids Reduction Equipment, and what kind of problems are common in wastewater? 2. What types
More informationInfiltration basin under normal conditions, with generous grassed area for water soakage (Source: WSUD in the Sydney Region)
Practice Notes Infiltration basin under normal conditions, with generous grassed area for water soakage (Source: WSUD in the Sydney Region) Water sensitive development involves simple design and management
More informationRoediger Vacuum GmbH Kinzigheimer Weg Hanau, Germany Phone: Telefax:
Roediger Vacuum GmbH Kinzigheimer Weg 104-106 63450 Hanau, Germany Phone: +49 6181 309-274 Telefax: +49 6181 309-277 www.roevac.com export@roevac.com RV EN Sewerage 10/2007-1001 RoeVac Vacuum Sewer Systems
More informationOwners Manual for the Rainmaster Water Recycling System
Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your
More informationHomeowners Guide to Stormwater BMP Maintenance
Homeowners Guide to Stormwater BMP Maintenance What You Need to Know to Take Care of Your Property Rain Barrel Dry Well Rain Garden Pervious Asphalt Porous Pavers City of El Monte Stormwater BMP Management
More informationSondex - A World of Heat Exchangers For All Applications
Sondex - A World of Heat Exchangers For All Applications SONDEX HEAD OFFICE Sondex - A Leading Manufacturer of Plate Heat Exchangers Sondex A/S, a Danish company, was founded in 1984 by Mr. Aa. Søndergaard
More informationSPECIFICATION SECTION:
SPECIFICATION SECTION: Date: STORM WATER TREATMENT STORMEXX CLEAN CATCH BASIN INSERTS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the Inserts for use at existing storm water catch basins in roadways,
More informationWQ-07 INFILTRATION TRENCH
Greenville County Technical Specification for: WQ-07 INFILTRATION TRENCH 1.0 Infiltration Trench 1.1 Description Infiltration Trenches are excavations filled with stone to create an underground reservoir
More informationSewer & Storm Drain Systems
Sewer & Storm Drain Systems Institute for Facilities Management Sewer & Storm Drain Systems Jay W Becker, PE 1 Course Overview Campus Sewer and Drainage o Sanitary Sewer System o Storm Drain System o Understanding
More informationInterSeptor Centrifugal Separators Operating & Maintenance Manual
General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this
More informationrainwise Working with communities to manage rainwater
rainwise Working with communities to manage rainwater RAINWISE At Northumbrian Water we are working with communities and our partners to manage the amount of surface water (rainwater from roofs, roads
More informationBioretention Systems
New Jersey Stormwater Best Management Practices Manual February 2009 Definition Purpose C H A P T E R 9. 1 Bioretention Systems A bioretention system consists of a soil bed planted with suitable non-invasive
More informationScreen and Trash Rakes. MUHR Hydraulic and Cable Operated Raking Mechanisms
Screen and Trash Rakes MUHR Hydraulic and Cable Operated Raking Mechanisms Cable Operated Raking Systems Catronic Series Trash Rakes The Catronic Series Trash Rake provides a reliable and efficient method
More informationSwatara Township Stormwater Program. 1. There are no storm sewers on or near my property. Why should I pay a fee?
1. There are no storm sewers on or near my property. Why should I pay a fee? All properties produce stormwater runoff that must be managed by the Township. Even if your property has never flooded and there
More informationAir treatment solutions. Aftercoolers & condensate treatment
Air treatment solutions Aftercoolers & condensate treatment RELIABLE AND CLEAN AIR Atlas Copco aftercoolers and condensate treatment The air that leaves a compressor reaches 100% humidity. It also contains
More informationTips for Maintaining and Enhancing Stormwater Management Areas
4 4 N. Second Street, Denton, Md. 21629 (410) 479-3625 (410) 479-3534 fax www.dentonmaryland.com Tips for Maintaining and Enhancing Stormwater Management Areas Information provided by the Town of Denton
More informationBest Management Practices (BMPs)
Best Management Practices (BMPs) Prevent Blockages in the Sanitary Sewer System Properly Maintain Grease Traps and Interceptors to Prevent Introduction into the Sanitary Sewer System Prevent Fats, Oil,
More informationCLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes
CLEACOM Engineered System Solutions Established 24/7 technology for the separation of dust and fume during compounding processes Reduced consumption of resources with dry separation. Wet separation with
More informationIRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems
IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems ODIS Filtration is The Heart of Every Irrigation System 12 TABLE OF CONTENTS Manifolds & Accessories... 2 Series
More informationAPPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps
APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual Suggestions for the hydraulic integration of chillers and heat pumps Table of Contents From practical experience, for your practical needs...
More informationRead Only Document Not For Distribution
Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.
More informationHomeowners Manual. Thank you!
Homeowners Manual Thank you! Thank you for purchasing a Blue Square Q360 In-Floor Cleaning System! With over 20 years of pool building and in-floor knowledge, this system was designed with you, our pool
More informationAn Introduction to Sustainable Drainage
An Introduction to Sustainable Drainage Systems (SuDS) This resource has been produced by Newground who work in partnership with the Environment Agency Last reviewed: Nov 2018 For more information visit:
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationIntroduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective
2012 Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective 2012 - Superior Restaurant Services 3/21/2012 2012 - Superior Restaurant Services 2 Contents Introduction...
More informationPipe Sizing Table. Hydraulic Load Served (fixture units)
MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3
More informationGreen and Gray Infrastucture
Learning Objectives Make Your Vegetated Roof Work Harder as a Stormwater BMP Richard C. Hayden, RLA ASLA CLARB American Hydrotech, Inc. Brian Taylor, PE AMEC 1. Learn how vegetated roofs can be used as
More informationDomestic Water Tank Cleaning Machine
Domestic Water Tank Cleaning Machine Operational Manual Dear Customer, Thanks for purchasing this innovative product. The aim for this product development is for achieving followings. 1. Reduce water wastage
More informationGreen Infrastructure and Low-Impact Development Technologies
Green Infrastructure and Low-Impact Development Technologies The guiding principles of these technologies is to manage stormwater at their sources using natural means, and establish conditions so that
More informationmagnetite separator New: Dirt and TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR
New: Dirt and magnetite separator TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR AIR, GASES AND CONTAMINANTS IN HYDRONIC PLANT SYSTEMS The energy wasted as a result of trapped particles in flow systems
More informationCHAPTER 10 TRAPS AND INTERCEPTORS
CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved
More informationCleaning System. Amajet. Type Series Booklet
Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationSeparators for light liquids. Sepurator BLUE. purator
Separators for light liquids Sepurator BLUE Sepurator BLUE separators for light liquids The new, flow-optimized Sepurator BLUE separators for light liquids (oil separator) are constructed according to
More informationTrusted Expertise in Domestic and Commercial Wastewater
Trusted Expertise in Domestic and Commercial Wastewater Any Project, Any Wastewater Application Wastewater poses a complex challenge, no matter whether it originates in a single house or a multifamily
More informationHazen and Sawyer 545 Mainstream Drive, Suite 320 Nashville, TN
Hazen and Sawyer 545 Mainstream Drive, Suite 320 Nashville, TN 37228 615.783.1515 Central WWTP Capacity Improvements and CSO Reduction Technical Memorandum No. 2: New Headworks Facility Hazen No. 50045-006
More informationMAINTENANCE APPENDIX. G.1 Introduction. G.1.1 Goals and Objectives
APPENDIX G MAINTENANCE G.1 Introduction The maintenance of LID facilities is essential to ensure that designed stormwater management performance and other benefits continue over the full life cycle of
More informationPoly Series. Polymer Preparation Unit
Poly Series Polymer Preparation Unit 02 Solutions for Water & Industry Seko s Poly Series has been specifically designed to provide effective solutions to the needs of Water Treatment Customers. The Poly
More informationCoarse Coal Centrifuges. VM1650 is the world s largest capacity Coarse Coal Centrifuge
Process Equipment 2 3 Coarse Coal Centrifuges VM1650 is the world s largest capacity Coarse Coal Centrifuge FLSmidth Ludowici manufactures a range of centrifuges that have established an unequalled track
More informationEuroPEK Oil Separator
www.wavin-labko.fi WAVIN-LABKO LTD Labkotie 1 FIN-36240 KANGASALA Tel: +358 20 1285 270 Fax: +358 20 1285 280 E-mail: tanks@wavin-labko.fi 01/04 EuroPEK Oil Separator Instructions for Installation, Operation