IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

Size: px
Start display at page:

Download "IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):"

Transcription

1 IJSRD - International Journal for Scientific Research & Developent Vol. 3, Issue 3, 215 ISSN (online): Theral Perforance of Waste Heat Recovery by using TPCT Heat Exchanger Charged with Nanofluid Akash shetty 1 Nikhil Shedge 2 Akshay Talekar 3 Zakar Shirawale 4 Rahul Pise 5 1,2 Navsahyadri Education Society s Group of Institutions, Pune Abstract Hot air plays an iport role in ode life. The consuption of hot air represents a significant part of the nation's energy consuption. One way of reducing the energy consuption involved, and hence the cost of that energy, is to reclai heat fro the waste war air that is discharged to the sewer each day. The potential for econoic waste air heat recovery depends on both the quantity available and whether the quality fits the requireent of the heating load. To recover heat fro waste air in residential and coercial buildings is hard to achieve in quality because of its low teperature range. Nevertheless, efforts to recycle this waste energy could result insignificant energy savings. The objective of this research was to develop a two phase closed therosyphon heat exchanger charged with nanofluid for a waste air heat recovery syste. The advantage of the syste proposed in this work is that it provides useful energy transfer during siultaneous flow of cold supply and war drain air. While this concept is not new, the design of the TPCT heat exchanger with nanofluid for the present study is significantly different fro those used previously. Coponent experients were carried out to deterine the perforance characteristics of a heat pipe heat exchanger charged with nanofluid. By replacing the conventional fluid in heat pipe with CuO/H2O nanofluid (2% volue fraction) of the heat pipe heat exchanger good perforance can be obtained. The axiu effectiveness obtained for proposed TPCT CuO/H2O charged nanofluid heat exchanger is.2862 (2% volue fraction copared with effectiveness.16 obtained with conventional heat pipe working fluid. The influence of ass flow rate and source teperature on effectiveness of TPCTHX exhibits sae pattern as that of conventional working fluid. The axiu enhanceent in effectiveness obtained is 35%.Thus the nanofluid as working fluid in TPCT enhances the effectiveness of heat exchanger. Key words: TPCT, Nanofluid I. INTRODUCTION Hot air plays an iport role in ode life. The consuption of hot air represents a significant part of the nation's energy consuption. One way of reducing the energy consuption involved, and hence the cost of that energy, is to reclai heat fro the waste war air that is discharged to the sewer each day. The potential for econoic waste air heat recovery depends on both the quantity available and whether the quality fits the requireent of the heating load. To recover heat fro waste air in residential and coercial buildings is hard to achieve in quality because of its low teperature range. Nevertheless, efforts to recycle this waste energy could result insignificant energy savings. The objective of this research is to develop a two phase closed therosyphon heat exchanger charged with nanofluid for a waste air heat recovery syste. The advantage of the syste proposed in this work is that it provides useful energy transfer during siultaneous flow of cold supply and war drain air. While this concept is not new, the design of the TPCT heat exchanger with nanofluid for the present study is significantly different fro those used previously. Coponent experients were carried out to deterine the perforance characteristics of a heat pipe heat exchanger charged with nanofluid. By replacing the conventional fluid in heat pipe with CuO/H2 nanofluid (2% volue fraction) of the heat pipe heat exchanger good perforance can be obtained. The axiu effectiveness obtained for proposed TPCT CuO/H2 charged nanofluid heat exchanger is.2862 (2% volue fraction copared with effectiveness.16 obtained with conventional heat pipe working fluid. The influence of ass flow rate and source teperature on effectiveness of TPCT HX exhibits sae pattern as that of conventional working fluid. The axiu enhanceent in effectiveness obtained is 35.6%. Thus the nanofluid as working fluid in TPCT enhances the effectiveness of heat exchanger. II. LITERATURE SURVEY Yodraket et al. [1] studied heat recovery syste at Furnace in a Hot Forging Process; he concluded that the experient findings indicated that when the hot gas teperature increased, the heat transfer rate also increased. If the internal diaeter increased, the heat transfer rate increased and when the tube arrangeent changed fro inline to staggered arrangeent, the heat transfer rate increased. The heat pipe air-preheated can reduced the quantity of using gas in the furnace and achieve energy thrift effectively. Noie-Baghbanet et al. [2] carried out the research on the theory, design and construction of heat pipes, especially their use in heat pipe heat exchangers for energy recovery, reduction of air pollution and environental conservation. A heat pipe heat exchanger has been designed and constructed for heat recovery in hospital and laboratories, where the air ust be changed up to 4 ties per hour. In This research, the characteristic design and heat transfer liitations of single heat pipes for three types of wick and three working fluids have been investigated, initially through coputer siulation. Construction of heat pipes, including washing, inserting the wick, creating the vacuu, injecting the fluid and installation have also been carried out. After obtaining the appropriate heat flux, the airto-air heat pipe heat exchanger was designed, constructed and tested under low teperature (15±55C) operating conditions, using ethanol as the working fluid. Experiental results for absorbed heat by the evaporator section are very close to the heat transfer rate obtained fro coputer siulation. Saan et al. [9] exained the possible use of a heat pipe heat exchanger for indirect evaporative cooling as well as heat recovery for fresh air preheating. Theral All rights reserved by

2 perforance of a heat exchanger consisting of 48 therosyphon arranged in six rows was evaluated. The tests were carried out in a test rig where the teperature and huidity of both air streas could be controlled and onitored before and after the heat exchanger. Evaporative cooling was achieved by spraying the condenser sections of the therosyphon. The paraeters considered include the wetting arrangeent of the condenser section, flow ratio of the two streas, initial teperature of the priary strea and the inclination angle of the therosyphon. Their results showed that indirect evaporative cooling using this arrangeent reduces the fresh air teperature by several degrees below the teperature drop using dry air alone. Huidity control is a never-ending war in tropical hot and huid built environent. Heat pipes are passive coponents used to iprove dehuidification by coercial forced-air HVAC systes. They are installed with one end upstrea of the evaporator coil to pre-cool supply air and one downstrea to re-heat supply air. This allows the syste's cooling coil to operate at a lower teperature, increasing the syste latent cooling capability. Heat rejected by the downstrea coil reheats the supply air, eliinating the need for a dedicated reheat coil. Heat pipes can increase latent cooling by 25-5% depending upon the application. Conversely, since the reheat function increases the supply air teperature relative to a conventional syste, a heat pipe will typically reduce sensible capacity. In soe applications, individual heat pipe circuits can be controlled with solenoid valves to provide iproved latent cooling control. Priary applications are liited to hot and huid cliates and where high levels of outdoor air or low indoor huidity are needed. Hospitals, superarkets and laboratories are often good heat pipe applications. Yauet et al. [1] entioned that for any years, heat pipe heat exchangers (HPHEs) with two-phase closed therosyphon, and has been widely applied as dehuidification enhanceent and energy savings device in HVAC systes. Coponents used to iprove dehuidification by coercial forced-air HVAC systes. They are installed with one end upstrea of the evaporator coil to pre-cool supply air and one downstrea to re-heat supply air. This allows the syste's cooling coil to operate at a lower teperature, increasing the syste latent cooling capability. Heat rejected by the downstrea coil reheats the supply air, eliinating the need for a dedicated reheat coil. Heat pipes can increase latent cooling by 25-5% depending upon the application. Conversely, since the reheat function increases the supply air teperature relative to a conventional syste, a heat pipe will typically reduce sensible capacity. In soe applications, individual heat pipe circuits can be controlled with solenoid valves to provide iproved latent cooling control. Priary applications are liited to hot and huid cliates and where high levels of outdoor air or low indoor huidity are needed. Hospitals, superarkets and laboratories are often good heat pipe applications. Mousa et al. [1]carried out an experiental study on an effect of nanofluid in Circular Heat Pipe. The nanofluid consisted of Al2O3 nanoparticles with a diaeter of 1 n. The experiental data of the nanofluids were copared with those of DI water including the wall teperatures and the total heat resistances of the heat pipe. Experiental results showed that if concentration of the nanofluid increasing, then the theral resistance of heat pipe decreased. Shang et al. [18] investigated the heat transfer characteristics of a closed loop OHP with Cu water nanofluids as the working fluid different filling ratios. The results were copared with those of the sae heat pipe with distilled water as the working fluid. The experiental results are confired that the use of Cu water nanofluids in the heat pipe could enhance the axiu heat reoval capacity by 83%. It was confored that directly adding nanoparticles into distilled water without any stabilizing agents had greater heat transfer enhanceent copared to the case where a stabilizing agent was added to the distilled water. III. DESIGN AND DEVELOPMENT OF EXPERIMENTAL SETUP As described earlier proposed work ais to investigate of experiental perforance of heat pipe heat exchanger charged with CuO/H2 Nanofluid under variable source teperatures and ass flow rate. With broad perspective this study ais to investigate the feasibility of heat pipe fro low teperature waste heat source. In order to achieve the objectives stated above it has been decided to design and develop the experiental syste as shown in following Figure 1. Heat pipe heat exchangers are devices that ade the exchange of energy (waste heat) fro a waste heat source to a colder source. Figure 1 shows the scheatic diagra of the experiental syste. The syste is coposed of three ajor parts: air heater (for waste hot air preparation), heat pipe heat exchanger and devices for easureent and control of paraeters. In the installation there are two circulating fluids: the hot agent (waste air) in the lower chaber of the heat exchanger and the cold agent (cold air) in the upper chaber of the heat exchanger. The heat pipe heat exchanger was equipped with eight heat pipes arranged vertically at an angle of 9 (Figure1). The working fluid used in heat pipe is CuO/H2O nanofluid. All rights reserved by 194

3 Fig 1: Scheatic layout of proposed experiental syste Fig. 2: 3D Representation of Experiental Set Up IV. DESIGN AND DEVELOPMENT OF HEAT PIPE HEAT EXCHANGER Heat pipe diensions is choose as per below table. While designing heat pipe it has to be undergoes under liit checking. Theral properties of CuO nanofluid are selected fro various sources and it is used for calculation heat pipe liit. By using various correlations fro literature survey heat flux under various liits is calculated for checking safety of design of heat pipe. Sr. Notat Valu Uni Paraeters No ion e t.2 1 Evaporator Length L v 5 2 Adiabatic Length L add Condenser Length L c 5 4 Total Length L t.6 5 Effective Length L eff.55 6 Inner Radius r i Cross Section Area A Axial Angle Ø 9 O 9 Theral Conductivity of W/ λ 385 Material (Copper) k 1 Vapour Core Radius r v 11 Evaporative Section Radius r e 12 Condenser Section Radius r c All rights reserved by

4 13 14 Nano Particle Volue Fraction Density of Nanoparticle kg/ ρ np (CuO) 21 3 Table-1: Heat pipe paraeters A. Heat Pipe Liit Calculation Heat pipes undergo various heat transfer liitations depending on the working fluid, the diensions of the heat pipe, and the heat pipe operational teperature. 1) Viscous liitation: The viscous liit occurs at low operating teperatures, where the saturation vapour pressure ay be of the sae order of agnitude as the pressure drop required driving the vapour flow in the heat pipe. This results in an insufficient pressure available to drive the vapour. The viscous liit is soeties called the vapour pressure liit (4.2) 2) Sonic liitation: The sonic liit is due to the fact that at low vapour densities, the corresponding ass flow rate in the heat pipe ay result in very high vapour velocities, and the occurrence of choked flow in the vapour passage ay be possible. (4.3) 3) Entrainent liitation: The entrainent liit refers to the case of high shear forces developed as the vapour passes in the counter flow direction over the liquid saturated wick, where the liquid ay be entrained by the vapour and returned to the condenser. This results in insufficient liquid flow of the wick structure. (4.4) 4) Boiling liitation: The boiling liit occurs when the applied evaporator heat flux is sufficient to cause nucleate boiling in the evaporator wick. This creates vapor bubbles that partially block the liquid return and can lead to evaporator wick dry out. The boiling liit is soeties referred to as the heat flux liit. Tep C Sonic Liit kw/ 2 Viscous liit kw/ 2 ( ) (4.5) Entrainent Liit kw/ 2 Boiling Liit kw/ Table-2: Heat Pipes Liits for Various Operating Teperatures It has been noticed that the aount of wattage to be transferred to which heat pipe is designed is below the axiu axial heat flux for variable teperature and thus design of heat pipe were observed to be successful. Fig. 3: Heat Pipes Liits for Various Operating Teperatures V. EXPERIMENTATION A. Test Methodology: 1) In order to investigate the theral perforance of TPCT heat recovery heat exchanger charged with nanofluid under variable source teperature and ass low rate, it has been decided to vary the heat input fro 25 to 1 W in the step of 25 W. The ass flow rate is varied fro 1 cf to 4 cf in the step of 1 cf. 2) For a particular heat input the ass flow rate of hot and cold air streas are varied fro 1 to 4 cf as entioned above. 3) At steady state the hot and cold air strea inlet and outlet teperatures across heat pipe heat exchanger is easured. 4) The corresponding volteter and aeter readings are noted and power supplied to electrical heater is calculated. 5) Air velocity is easured with the help of air vane aneoeter. B. Test Paraeters: Experientation was carried on the TPCT HRHX. Working fluid is iportant paraeter in the experientation. CuO/H2O nanofluid was used as a working fluid. Other paraeters and its description are as follows. Paraeter Description Heat load (W) 25 W to 1 W Source teperature up to 65 C Mass flow rate ().512 to.249 kg/s Discharge of Blower 1 to 4 cf Velocity 1.4 to 5.24 /s Table-3: Test Paraeters The heat input, effectiveness of heat exchanger is calculated by the following equations. (W) Where, V= Voltage, I=Current Effectiveness of heat exchanger = Qactual/ Q ax Heat transfer coefficient can be calculated by using equation Q= h A ΔT All rights reserved by

5 Inlet Tep in C Effectiveness ΔT Inlet Tep in C VI. RESULT AND DISCUSSION The experiental perforance of heat pipe heat exchanger was experientally evaluated. Experientation was carried out to investigate the effect of heat input and ass flow rate of hot and cold air streas on the effectiveness of heat exchanger. On the basis of the observations recorded the effectiveness of heat exchanger for particular heat input and ass flow rate of hot and cold air streas were calculated. For given heat input with increase in ass flow rate of air the teperature difference decreases. The nuerical and graphical variation of the teperature difference is shown in Figure Variation in ΔT at Evaporator section Hot air strea flow rate (3/s) 25W 5W 5W 1W Fig. 4: Variation in ΔT at Evaporator Section For given heat input with increase in ass flow rate of air the teperature difference decreases. The nuerical and graphical variation of the teperature difference is shown in Figure 5. Fig. 6: Variation in Inlet Teperature at Evaporator Section Variation in outlet teperature of evaporator section is observed due to the absorption of the heat by heat pipe working fluid during the phase change. At evaporator section working fluid absorbs the heat and it gets evaporated. So at the outlet of evaporation section teperature decrease and Figure shows the variations Variation in outlet teperature at evaporator section W 5W 5W 1W Hot air strea flow rate (3/s) Fig. : Variation in Outlet Teperature at Evaporator Section With increase in heat input the teperature at the outlet of condenser section increases. Figure 8 shows variation in outlet teperature at condenser section. Fig. 5: Variation in ΔT at Condenser Section Variation in inlet teperature at evaporator section is observed due to the heat input supplied to the fin tube heater with increase in heat input, teperature at inlet of evaporator section increases and Figure 6 shows the variations Variation in inlet teperature at evaporator section Hot air strea flow rate (3/s) 25W 5W 5W 1W Fig. 8: Variation in Outlet Teperature at Condenser Section Figure 9 shows the variation in the effectiveness at evaporator section of heat exchanger with variation in heat input. It is observed that the effectiveness of two phase closed therosyphon charged with nanofluid increases with increase in heat input for a particular air strea flow Variation in effectiveness of HX with heat input W 5W 5W 1W Air strea flow rate ( 3 /s) Fig. 9: Variation in Effectiveness of HX with Heat Input All rights reserved by

6 Heat Transfer Coefficient Figure 1 shows the variation in the effectiveness of heat exchanger at condenser section with variation in heat input. It is observed that the effectiveness of two phase closed therosyphon charged with nanofluid increases with increase in heat input for a particular air strea flow Variation in Heat Transfer Coefficient of HX with heat input 1.5 /s 2.1 /s 3.15 /s 4.19 /s Heat Input (W) Fig. 1: Variation in Heat Transfer Coefficient of HX with Heat Input Figure 11 shows the variation in the Nusselt Nuber at evaporator section of heat exchanger with variation in heat input. It is observed that the effectiveness of two phase closed therosyphon charged with nanofluid increases with increase in heat input for a particular air strea flow. Fig. 11: Variation in Nusselt Nuber of HX with Heat Input 1) The perforance of heat pipe heat exchanger charged with CuO/H2 nanofluid increases with increase in source teperature. 2) Maxiu effectiveness observed for proposed heat pipe heat exchanger is up to.32. 3) The results obtained for TPCT heat exchanger charged CuO/H2 nanofluid are superior with that of TPCT charged with conventional fluid. 4) Enhanceent in effectiveness of heat exchanger for current study is about 35% copared with the available literature. 5) Iproveent in effectiveness of two phase closed therosyphon heat exchanger charged with nanofluid is due to theral conductivity enhanceent of nanofluid. 6) TPCT heat recovery heat pipe heat exchanger can be suitably eployed for heat recovery fro low source teperature. REFERENCES [1] YodrakL., Sapan R., Waste Heat Recovery by Heat Pipe Air-Preheater to EnergyThrift fro the Furnace in a Hot Forging Process, Aerican Journal of Applied Sciences21. (5),pp [2] Noie-Baghban,MajideianG., Waste heat recovery using heat pipe heat exchanger(hphe) for surgery roos in hospitals, Journal of Applied Theral Engineering, 2, pp ,. [3] SaanW. Perforance of a therosyphon heat exchanger in an evaporative air conditioning syste, Proc. 5th Australasian heat & Mass Transfer Conference, Brisbane, [4] Yau Y., TuckerA., The perforance study of a wet sixrow heat pipe heat exchanger operating in tropical buildings, International Journal of Energy Research 2, 23, pp, [5] MousaM., Effect of nanofluid concentration on the perforance of circular heat pipe,ains Shas Engineering Journal (211) 2, pp [6] Shang X.,Liu Z., Heat transfer perforance of a horizontal icro grooved heat pipe using CuOnanofluid, Microechanics and Micro engineering 18 (28),pp VII. CONCLUSION The experiental investigation was carried out on two phase closed therosyphon heat pipe heat exchanger charged with CuO/H2 nanofluid. The effect of source teperature and ass flow rate of hot and cold air streas on effectiveness of nanofluid charged TPCT heat exchanger was experientally investigated. The heat input to finned tube air heater was varied fro 25 W to 1 W and hot and cold air strea flow rate varied fro /s to /s. The effect of variation in source teperature and ass flow rate of hot and cold air streas on effectiveness of heat exchanger was experientally studied. The heat pipes used in heat exchanger was specially designed for heat recovery application. Conclusions fro studied experient are as follows, All rights reserved by

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE Mr. Jaydev S. Bade 1, Dr. Nitin U. Korde 2 1 Student, Mechanical Engineering Department,

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

CHAPTER 4 EXPERIMENTAL STUDIES

CHAPTER 4 EXPERIMENTAL STUDIES 113 CHAPTER 4 EXPERIMENTAL STUDIES 41 INTRODUCTION Based on the results of the theoretical studies on the air-cooled GAX based vapour absorption refrigeration syste that were carried out, the design and

More information

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid www.ierjournal.org International Engineering Research Journal (IERJ) Volume 1 Issue 6 Page 474-478, 215, ISSN 2395-1621 ISSN 2395-1621 Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid #1 Tushar

More information

ANALYSIS OF A BUBBLE PUMP DRIVEN ABSORPTION REFRIGERATION SYSTEM (EINSTEIN-SZILARD REFRIGERATOR VARIANT)

ANALYSIS OF A BUBBLE PUMP DRIVEN ABSORPTION REFRIGERATION SYSTEM (EINSTEIN-SZILARD REFRIGERATOR VARIANT) International Journal of Mechanical Engineering and Technology (IJMET) Volue 7, Issue 6, Noveber Deceber 2016, pp.435 442, Article ID: IJMET_07_06_042 Available online at http://www.iaee.co/ijet/issues.asp?jtype=ijmet&vtype=7&itype=6

More information

Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications

Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications 1 Jaydev S. Bade, 2 Nitin Korde, 3 Anurag Hatwar 1 ME Heat Power GHRCOEM, Ahmednagar 2 Department

More information

Numerical Study on the Performance Characteristics of a Rotary Regenerator according to Design Parameters

Numerical Study on the Performance Characteristics of a Rotary Regenerator according to Design Parameters Nuerical Study on the Perforance Characteristics of a Rotary Regenerator according to Design Paraeters HYUN JOON CHUNG 1, DOWON CHA 1, HOON KANG 2, YONGCHAN KIM 2 1 School of Mechanical Engineering Korea

More information

Waste heat recovery using nanofluid charged heat pipe heat exchanger (HPHE) for variable Source

Waste heat recovery using nanofluid charged heat pipe heat exchanger (HPHE) for variable Source ISSN 2395-1621 Waste heat recovery using nanofluid charged heat pipe heat exchanger (HPHE) for variable Source #1 Mr. Vikramsinh Magar, #2 Mr.Vishasinha Bhosale 1 vikramhmagar@gmail.com 2 vishasinhabhosale@gmail.com

More information

Investigation of Metal and Metal Oxide nanocoating on Fins in HPHE with Silver Water NanoFluid

Investigation of Metal and Metal Oxide nanocoating on Fins in HPHE with Silver Water NanoFluid American Journal of Mechanical Engineering, 2015, Vol. 3, No. 1, 21-25 Available online at http://pubs.sciepub.com/ajme/3/1/4 Science and Education Publishing DOI:10.12691/ajme-3-1-4 Investigation of Metal

More information

Extension of a Virtual Refrigerant Charge Sensor

Extension of a Virtual Refrigerant Charge Sensor Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Extension of a Virtual Refrigerant Charge Sensor Woohyun i ki644@purdue.edu

More information

PROCEEDINGS SOLAR 95

PROCEEDINGS SOLAR 95 PROCEEDINGS OF GOlDEN, C0kOf?~W0 8&i#%V3 SOLAR 95 THE 1995 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE Minneapolis, Minnesota July 1520,1995 Editors: R. Capbell-Howe B. Wilkins-Crowder Aerican Solar

More information

American International Journal of Research in Science, Technology, Engineering & Mathematics

American International Journal of Research in Science, Technology, Engineering & Mathematics American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-358, ISSN (CD-ROM): 2328-3629

More information

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV) Research Journal of Applied Sciences, Engineering and Technology 5(3): 865-869, 2013 ISSN: 2040-7459; E-ISSN: 2040-7467 Maxwell Scientific Organization, 2013 Submitted: June 13, 2012 Accepted: July 09,

More information

Experimentation of Heat Pipe Used In Nano-Fluids

Experimentation of Heat Pipe Used In Nano-Fluids Experimentation of Heat Pipe Used In Nano-Fluids 1 Prashant Shinde, 2 Vinod Shinde, 3 Rajiv Talape, 4 D.N. Korade 1,2,3,4 Department of Mechanical Engineering, Sinhgad Institute of Technology & Science,

More information

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Enhancement of COP using Nanoadditives in Domestic Refrigerator ISSN 2395-1621 Enhancement of COP using Nanoadditives in Domestic Refrigerator #1 Mr.Sajjan Kawade, #2 Prof P.T.Kharat 1 sajjankawade@gmail.com 2 pradip5872@gmail.com #1 P.G. Student, Mechanical Engineering

More information

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe.

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe. Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe. Anuradha V. Patil., Dr. Pradeep A. Patil. Department of Mechanical Engineering, JSPMs JSCOE, Hadapsar, Pune,

More information

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM 1 RONANKI SURESH, 2 Dr. K. KALYANI RADHA 1 M.Tech, Mechanical Engineering, JNTUA College of Engineering

More information

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV) Australian Journal of Basic and Applied Sciences, 5(7): 638-643, 2011 ISSN 1991-8178 Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves

More information

SIMULATION STUDY ON HEAT TRANSFER RATE ON AIR CONDITIONING CONDENSER BY VARYING MATERIAL PROPERTIES AND ORIENTATION

SIMULATION STUDY ON HEAT TRANSFER RATE ON AIR CONDITIONING CONDENSER BY VARYING MATERIAL PROPERTIES AND ORIENTATION SIMULATION STUDY ON HEAT TRANSFER RATE ON AIR CONDITIONING CONDENSER BY VARYING MATERIAL PROPERTIES AND ORIENTATION MUNIGONDA VIJAY KUMER M.TECH (theral engineering) MLR Institute of Technology, Hyderabad.

More information

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only, Cofort Circular Unit Heater COMFORT Sabiana circular unit heaters, for ceiling installation only, are especially suitable for high roos, even if the optiu ratio between the air flow-rate and the heat output

More information

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment

More information

Atlas and Helios Unit Heaters Janus 05 Air Conditioners AIX Stainless Steel Unit Heaters Atlas STP Door Curtains Jetstream Induction Flow Optimizers

Atlas and Helios Unit Heaters Janus 05 Air Conditioners AIX Stainless Steel Unit Heaters Atlas STP Door Curtains Jetstream Induction Flow Optimizers Copliant with ERP 0 Regulation (EU) No. /0 Cert. n 0 Heating / Air Conditioning Atlas and Helios Unit Heaters Janus 0 Air Conditioners AIX Stainless Steel Unit Heaters Atlas STP Door Curtains Jetstrea

More information

Review on Waste heat recovery application and scope of Heat pipe heat exchanger charged with Nanofluid

Review on Waste heat recovery application and scope of Heat pipe heat exchanger charged with Nanofluid ISSN 2395-1621 Review on Waste heat recovery application and scope of Heat pipe heat exchanger charged with Nanofluid #1 Mr. Makarand Dharmadhikari, #2 Dr. R.K.Patil 1 PVPIT, Bavdhan, Pune, India makarand_pd@rediffmail.com

More information

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.102 111, Article ID: IJMET_07_03_009 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3

More information

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental

More information

EXPERIMENTAL ANALYSIS OF SOLAR AIR DRYER FOR AGRICULTURAL PRODUCTS

EXPERIMENTAL ANALYSIS OF SOLAR AIR DRYER FOR AGRICULTURAL PRODUCTS EXPERIMENTAL ANALYSIS OF SOLAR AIR DRYER FOR AGRICULTURAL PRODUCTS Sushrut S. Halewadiath 1, Prajwal Subbhapurath 2, Naveen Havaldar 3, Karthik Hunashikatti 4, Siddharth Gokhale 5 1 Assistant Professor,

More information

R10 IV B.Tech I Semester Supplementary Examinations, Feb/Mar REFRIGERATION & AIR CONDITIONING (Mechanical Engineering)

R10 IV B.Tech I Semester Supplementary Examinations, Feb/Mar REFRIGERATION & AIR CONDITIONING (Mechanical Engineering) Set No. 1 IV B.Tech I Seester Suppleentary Exainations, Feb/Mar - 2015 REFRIGERATION & AIR CONDITIONING (Mechanical Eineeri) Tie: 3 hours Max. Marks: 75 Anser any FIVE Questions All Questions carry equal

More information

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING ISSN (ONLINE): 2321-3051 INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING Heat Transfer Enhancement Techniques in Two Phase Closed Thermosyphon: A Review Faddas Nikhil A. 1,

More information

TEST REPORT #68. Chiao M. Lee Paul Laurentius. Hussmann Corporation St. Charles Rock Road Bridgeton, MO United States of America

TEST REPORT #68. Chiao M. Lee Paul Laurentius. Hussmann Corporation St. Charles Rock Road Bridgeton, MO United States of America Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Progra (Low-GWP AREP) TEST REPORT #68 Syste Drop-in Test of (R-448a) in a R04A Low and Mediu Teperature

More information

American International Journal of Research in Science, Technology, Engineering & Mathematics

American International Journal of Research in Science, Technology, Engineering & Mathematics American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-3580, ISSN (CD-ROM): 2328-3629

More information

15. Heat Pipes in Electronics (1)

15. Heat Pipes in Electronics (1) 15.1 Components of a Heat Pipe The three basic components of a heat pipe are: 15. Heat Pipes in Electronics (1) 15.1.1 The Container The function of the container is to isolate the working fluid from the

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

Precision Air Conditioners

Precision Air Conditioners MCAC-- Coercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: est region of Midea coercial air conditioner departent, Industry Avenue, Beijiao, Shunde, Foshan, Guangdong,

More information

Experimental Investigation of Heat Transfer Enhancement Techniques in Two Phase Closed Thermosyphon

Experimental Investigation of Heat Transfer Enhancement Techniques in Two Phase Closed Thermosyphon ISSN 2091-27 Experimental Investigation of Heat Transfer Enhancement Techniques in Two Phase Closed Thermosyphon Mr. Sandipkumar B. Chauhan, Mr. Dr. M. Basavaraj and Mr. Prashant Walke Student, M.Tech

More information

International Engineering Research Journal

International Engineering Research Journal Experimental Analysis of Closed Loop Pulsating Heat Pipe Using ZnO/Water Nanofluid S. V. GHADGE 1, Prof.A.B.AUTI 2 1 Mechanical Engineering, RSCOER s JSPM Narhe, SavitribaiPhule Pune University, Pune Maharashtra

More information

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid Available online at www.sciencedirect.com Procedia Engineering 38 (2012 ) 3715 3721 Conference Title Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid Senthilkumar R* a, Vaidyanathan

More information

REPRINT ZKG PROCESS PROCESS

REPRINT ZKG PROCESS PROCESS 4 Planning detail for integration of the into the existing plant peripherals a rotary feeder, the otor for 180 t/h of raw eal, for exaple, has a rating of 5.5 and during operation it uses less than 1.

More information

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl

More information

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a 2011 International Conference on Advanced Materials Engineering IPCSIT vol.15 (2011) (2011) IACSIT Press, Singapore Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a Eed Abdel-Hafez

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

HEAT PIPES

HEAT PIPES HEAT PIPES * Shaikh Naushad, Design Engineer PTC, Communication Concept, Saudi Arabia INTRODUCTION A heat pipe is a device that efficiently transports thermal energy from its one point to the other. It

More information

Drying Dynamics of Ulva Prolifera with the Heat Pump Microwave Method

Drying Dynamics of Ulva Prolifera with the Heat Pump Microwave Method Drying Dynaics of Ulva Prolifera with the Heat Pup Microwave Method Dan Su, Shujun Li *, Fengin Zhao, Youfu Cao Chinese Acadey of Agricultural Mechanization Sciences Beijing, China Abstract The drying

More information

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY MASS & E ERGY BALA CES I PSYCHROMETRIC PROCESSES EXPERIME T 3 1. OBJECTIVE The object of this experiment is to observe four basic psychrometric processes

More information

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM - 1 - EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM Shun YOSHIOKA, Hyunyoung KIM, Kazushige KASAI, Daikin Industries,

More information

AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS

AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS Frontiers in Heat Pipes Available at www.thermalfluidscentral.org AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS K. S. Ong

More information

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation.

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation. Thermodynamic Analysis of Heat Pipe Using Ammonia, Water and Ethanol with a View to Being Used in Refrigeration Ankit Dwivedi, R. S. Mishra Department of Mechanical Engineering, Delhi Technological University,

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Brig Gen Md. Lutfor Rahman, Sumaiya Nawrin, Rasel A Sultan Department of Mechanical Engineering, Military Institute

More information

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe 2011 International Conference on Communication Engineering and Networks IPCSIT vol.19 (2011) (2011) IACSIT Press, Singapore Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

Performance investigation of Air-conditioning system using ejector as expansion device

Performance investigation of Air-conditioning system using ejector as expansion device International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Performance

More information

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170

More information

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C drop analysis of evaporator using refrigerants R-22, R-404A and R-407C #1 Pallavi Sawkar, #2 Dr. Pradeep Patil #12 Department of Mechanical Engineering, JSPM s JSCOE, Savitribai Phule Pune University,

More information

II. OBJECTIVE OF RESEARCH

II. OBJECTIVE OF RESEARCH Enhancement of Coefficient of Performance of Vapor Compression Refrigeration System Using Diffuser at let of Condenser Mr. Nurul Seraj 1, Dr. S. C. Roy 2 1 Student, 2 Head of Department, Department of

More information

DESIGN, DEVELOPMENT AND TESTING OF CROSS FLOW CIRCULAR HEAT PIPE TO COOLING OF OIL

DESIGN, DEVELOPMENT AND TESTING OF CROSS FLOW CIRCULAR HEAT PIPE TO COOLING OF OIL DESIGN, DEVELOPMENT AND TESTING OF CROSS FLOW CIRCULAR HEAT PIPE TO COOLING OF OIL Vishnupant J. Sargar 1, Pruthveeraj D. Mali 2 1,2 Asst. Prof. Department of Mechanical Engineering, Adarsh Institute of

More information

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics Multi Split LG Multi Split syste is an advanced air conditioning syste of superior quality that has the ability to operate at different teperatures and fan speeds in individual roos. The ulti split syste

More information

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER Gourav Roy; Taliv Hussain; Rahul Wandra Department of Mechanical Engineering, Lovely Professional

More information

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe Someshwar S. Bhakre 1, Md. Rafik Sajjadahmad Choudhari 2 1, 2 PG Scholar, Mechanical Engineering

More information

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,

More information

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid. HEAT EXCHANGERS Heat Exchanger Heat exchanger is an apparatus or an equipment in which the process of heating or cooling occurs. The heat is transferred from one fluid being heated to another fluid being

More information

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online): IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online): 2349-6010 Githin V Sam Jethin Babu Jesvin Sam Jithin Victor Abstract Loop heat pipes

More information

PERFORMANCE OF WATER FILLED THERMOSYPHONS BETWEEN OC

PERFORMANCE OF WATER FILLED THERMOSYPHONS BETWEEN OC Frontiers in Heat ipes Available at www.thermalfluidscentral.org ERFORMANCE OF WATER FILLED THERMOSYHONS BETWEEN 30-150OC K. S. Ong* and Christopher Lim Department of Industrial Engineering, Universiti

More information

Experimental Study of Fins Effect on Thermal Performance of HPHX for Air Conditioning System

Experimental Study of Fins Effect on Thermal Performance of HPHX for Air Conditioning System IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 15, Issue 4 Ver. III (Jul. - Aug. 2018), PP 70-78 www.iosrjournals.org Experimental Study of Fins

More information

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12 EXPERIMENTAL ANALYSIS OF THE EFFECT OF FIN GEOMETRY ON HEAT TRANSFER RATE THROUGH THE REFRIGERATOR CONDENSER ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

More information

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack #1 Digvijay A. Shelar, #2 N.S. Gohel, #3 R. S. Jha #1 Mechanical Engineering Department,

More information

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Design and Development of Water Cooled Condenser for Domestic Refrigerator Design and Development of Water Cooled Condenser for Domestic Refrigerator Anil S. Patil Research PG Student, GF s Godavari College of Engineering, Jalgaon Dr. Atul A Patil Assot. Prof. GF s Godavari College

More information

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2, Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2, 1, 2 Assistant Professor, Department of Mechanical Engineering, Annamalai University, India, Abstract

More information

R245fa Evaporation Heat Transfer and Pressure Drop in a Brazed Plate Heat Exchanger for Organic Rankine Cycle (ORC)

R245fa Evaporation Heat Transfer and Pressure Drop in a Brazed Plate Heat Exchanger for Organic Rankine Cycle (ORC) Proceedins World Geotheral Conress 2015 Melbourne, Australia, 19-25 April 2015 R245fa Evaporation Heat Transfer and Pressure Drop in a Brazed Plate Heat Exchaner for Oranic Rankine Cycle (ORC) Kaiyon Hu

More information

2.2. General view of Microchannel Heat Exchangers

2.2. General view of Microchannel Heat Exchangers 2.2. General view of Microchannel Heat Exchangers In recent years, a very important contribution on increasing the performance of the heat exchangers has taken place, sometimes to levels once inconceivable,

More information

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,

More information

Mallikarjun 1, Anandkumar S Malipatil 2

Mallikarjun 1, Anandkumar S Malipatil 2 CFD Analysis of Air Cooled Condenser by Using Copper Tubes and Aluminum Fins Mallikarjun 1, Anandkumar S Malipatil 2 Abstract--In systems involving heat transfer, a condenser is a device or unit used to

More information

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling

More information

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE HEFAT2012 9 th International nference on Heat Transfer, Fluid Mechanics and Thermodynamics 16 18 July 2012 Malta FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE Kim K.,

More information

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS International Journal of Design and Manufacturing Technology (IJDMT) Volume 6, Issue 2, July-December 2015, pp. 14-18, Article ID: 30320150602003 Available online at http://www.iaeme.com/currentissue.asp?jtype=ijdmt&vtype=6&itype=2

More information

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger Chetan Papade Department of Mechanical Engineering N.K.Orchid college of Engg.& Tech., Solapur, Maharashtra,

More information

Technical Description

Technical Description Overview are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

Technical Description

Technical Description Overview are differentiated depending on applied edia. Light, one of the edia, is also utilized for a which is called a photoelectric. It is a non-contact type which is applicable to sensing presence,

More information

Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid

Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid Yogesh S Gandal Student, Mechanical Engineering Department, Indira College of Engineering and Management,

More information

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental

More information

Heat Dissipation in Control Panel using Heat Pipe

Heat Dissipation in Control Panel using Heat Pipe ISSN (e): 2250 3005 Volume, 07 Issue, 10 October 2017 International Journal of Computational Engineering Research (IJCER) Heat Dissipation in Control Panel using Heat Pipe Karan Hingmire 1 1 B.E mechanical,

More information

Enhancement of COP in Vapour Compression Refrigeration System

Enhancement of COP in Vapour Compression Refrigeration System Enhancement of COP in Vapour Compression Refrigeration System M. Krishna Prasanna #1 M.E student, Heat Transfer studies in Energy Systems Department of Mechanical Engg., Andhra University Visakhapatnam-530003,

More information

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Experimental Study of Direct Contact Condensation of Steam on Water Droplets , July 1-3, 2015, London, U.K. Experimental Study of Direct Contact Condensation of Steam on Water Droplets Semra GUMRUK, Murat K. AKTAS Abstract Air or water cooled condensers are used to reduce the moisture

More information

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System Prof. G.L.Allampallewar 1, Divyal P. Bagul 2, Abhiraj S. Galande 3, Amol M. Rathod 4, Ketan R. Behere 5. 1 Assistant

More information

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES International Journal of Mechanical and Materials Engineering (IJMME), Vol. 2 (2007), No. 2, 109--117. EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES M. Hasanuzzaman

More information

Development of a Compact Vacuum Freeze Drying for Jelly Fish (Schypomedusae)

Development of a Compact Vacuum Freeze Drying for Jelly Fish (Schypomedusae) Jurnal Teknologi Full paper Developent of a Copact Vacuu Freeze Drying for Jelly Fish (Schypoedusae). Idrus Alhaid *,. Yulianto, Nasruddin, Engkos A. Kosasih a Refrigeration and Air-Conditioning Laboratory,

More information

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors

Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors Eagle PIR-018 / PIR-045 / PIR-100 Outdoor Passive Infrared Detectors Description The Eagle Series of PIR-018, PIR-045 and PIR-100 Outdoor Passive Infrared Detectors are designed for detection of intruders

More information

Operation of a Two-Phase Reverse Loop Thermosyphon

Operation of a Two-Phase Reverse Loop Thermosyphon Journal of Applied Science and Engineering, Vol. 18, No. 3, pp. 259 264 (2015) DOI: 10.6180/jase.2015.18.3.06 Operation of a Two-Phase Reverse Loop Thermosyphon Meng-Chang Tsai 1, Shung-Wen Kang 2 *, Heng-Yi

More information

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) Indian Journal of Pure & Applied Physics Vol. 52, August 2014, pp. 531-540 Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV) S

More information

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners Volume 2, Issue 1, January 2017 ISSN (online): 2456-0006 International Journal of Science Technology Management and Research Available online at: Design, Development & Testing of Double Pipe Heat Exchanger

More information

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 12 June 2015 ISSN (online): 2349-784X Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger N. Manigandan

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler International Journal of Thermal Technologies E-ISSN 2277 4114 2015 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijtt/ Research Article Effect of Operating Parameters on the

More information

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER P. Sundaram and P. Sudhakar Department of Mechanical Engineering, SRM University, Kattankulathur, Chennai, India

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

EXPERIMENTAL PERFORMANCE OF AN R410A-FILLED C-SHAPE THERMOSYPHON

EXPERIMENTAL PERFORMANCE OF AN R410A-FILLED C-SHAPE THERMOSYPHON Frontiers in Heat Pipes Available at www.thermalfluidscentral.org EXPERIMENTAL PERFORMANCE OF AN R410A-FILLED C-SHAPE THERMOSYPHON K.S. Onga*, Gabriel Goha, K.H. Tshaia, W.M. Chinb bdaikin aindustrial

More information

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement

More information

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Review on Waste Heat Recovery Techniques in Air Conditioning Application International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Review Article Review

More information

Adsorption refrigeration system using waste heat

Adsorption refrigeration system using waste heat Adsorption refrigeration system using waste heat 1 RISHI SREEKUMAR, 2 SANJEEV SINGH, 3 HIMANSHU SHEKHAR, 4 RAUSHAN KUMAR, 5 Dr. R. S. BINDU 1,2,3,4 BE Students, 5 Professor Mechanical Engineering Department

More information