Montana Weatherization Program WEATHERIZATION FINAL INSPECTION REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI#
|
|
- Audrey Gibbs
- 5 years ago
- Views:
Transcription
1 EA #. Date Priority # HEALTH & SAFETY Hazardous Material Assessment Electrical Repairs Performed by Licensed Professional Solid Fuel Burning Appliance CO Detection/Warning, Occupant Education, # Installed. Montana Weatherization Program WEATHERIZATION FINAL REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI# FINAL RE Section a f c d,e e,f h DWH Closet Isolation Pier, Skirting Venting Smoke Alarm, # Installed Moisture Precautions Ground Moisture Barrier COMBUSTION TESTING Combustion Safety D Furnace f Testing/Diagnostics W /Boiler a,b Documentation H g Spillage Test Failure? Undiluted Flue CO: SS Efficiency: Outdoor Temp: Notes: Ambient CO Monitored (>35 PPM) Combustible Gas Leak Detection Visual Inspection of Appliance(s) CAZ Depressurization Test (Atmospheric Draft) Gas, LP Range Oven Test f e b c d,e d e
2 CAZ Depressurization Limit Appropriate for Installed Appliance Adequate Combustion Air (Atmospheric Draft) Complete Heating Worksheet (EAP-008) FINAL RE d,e c,d AIR SEALING Section 3 Attic Walls Windows, Doors Belly, Floor Ducts Duct Test Results Present b d Additions INSULATION Section 4 Insulation Certificate And Location Attic Above Roof Deck Insulation Insulation In Lid g h Insulation (Roof Over Construction) Roof Sealing Wall Insulate Transition Wall Exterior Wall Dense Packing Stuffing Fiberglass Batts (Wall) (Lift Siding) Through Wall Penetrations SPF in Cavities Above Door And Windows Belly Belly Insulation Prep Blown Floor Insulation Batt Floor Insulation
3 FINAL RE SPF Floor Insulation Basement Wall Insulation (No Ground Water Leakage) Water Line Protection/ Heat Tape Duct Insulation HEATING Visual assessment, data plate verification System airflow assessment Refrigerant line inspection (heat pump) Mobile Home approved furnace, solid fuel heat source Heating Controls, Thermostat Refrigerant charge evaluation (Heat Pump) appliance serial number confirmed Section a b Ventilation Section 6 Exhaust Ventilation Ducts (exhaust fan) Surface mounted In-line fan Fan placement Clothes dryer Kitchen range Supply Ventilation Complete ASHRAE Information in File? Nominal continuous ventilation fan setting: Run time setting: Notes: Exhaust Fan Flows: Kitchen1: Whole House: Kitchen2: : Bath1: Bath2: Bath3: h g f
4 FINAL RE BASELOAD Section 7 Refrigerator, Freezer LED s Installed, # CFL s Installed, # Washing Machine (BPA Only) Clothes Dryer Shower Head, Faucet Aeration DWH Selection, Mobile Home Approved DWH Installation DWH Maintenance Water Heater Insulation Pipe Insulation Aerator, Showerhead Water Temp. Checked? Home Left Clean, Replaced Appliances Removed i c c,i h c b b INCIDENTAL REPAIRS Window Repair Primary Window Storm Window /Install Door Repair Door MINOR REPAIRS Plumbing Leaks? Electrical Problems? CLIENT EDUCATION EES Report Operating Instructions for Fans or Thermostats. Manuals Maintenance Instructions Client Informed of Funding Source? Hazardous Conditions Noted During Weatherization?
5 Lead Documentation Present in Client File Pre-Retrofit Target Post Final Inspection SWS Ref. Blower Door Values Zone Pressure Test: Attic A DHW Closet Client s Acknowledgement of Final Inspection and Receipt of Required Literature A final inspection of the weatherization work was completed on my home; I am satisfied with the work and I have received all required literature related to the weatherization process. CLIENT S SIGNATURE Final Inspector s Acknowledgement A final inspection was completed on the home and all weatherization and health and safety measures were completed or have been addressed to the best my knowledge. INSPECTOR S SIGNATURE Re-Inspection Acknowledgements Measures that did not meet the Standardized Work Specifications that were brought into compliance to the best my knowledge. CLIENT S SIGNATURE INSPECTOR S SIGNATURE
SnuggPro DATA COLLECTION FORM
SnuggPro DATA COLLECTION FORM Section 1: General Information Trade Ally: Trade Ally Telephone: Trade Ally Email: Auditor Name: Auditor Telephone: Auditor Email: Home Owner Name: Home Owner Telephone: Home
More informationSpray Polyurethane Foam and Open-Combustion Appliances
Spray Polyurethane Foam and Open-Combustion Appliances Before applying SPF (spray foam polyurethane) insulation in an attic or crawl space it is important to determine if there are any appliances present,
More informationMBPA Home Performance FIELD DATA COLLECTION FORM
MBPA Home Performance FIELD DATA COLLECTION FORM Customer Information Test Date: Name Address City State Zip Phone: ( ) Email: Electric Provider Heating Fuel Provider Account Number Account Number Customer
More informationTASKS REGARDING COMBUSTION AIR
TASKS REGARDING COMBUSTION AIR DETERMINE IF THERE IS ENOUGH COMBUSTION AIR FOR THE TYPES OF APPLIANCES IN THE CAZ Use one of two methods, depending on appliance type and whether or not you have a blower
More informationIllinois Home Weatherization Assistance Program - Field Standards Manual
Illinois Home Weatherization Assistance Program - Field Standards Manual Contents 100 Diagnostic Standards 111 Blower Door 1111 House Set-Up 11111 Basements 1112 Blower Door Test 11121 Building Tightness
More informationEnergyMeasure HOME DATA COLLECTION FORM
EnergyMeasure HOME DATA COLLECTION FORM Section 1: General Information Customer Name: Site ID: Assessment Date: Street Address: City: State: Zip Code: Alternate Address: City: State: Zip Code: Telephone
More informationCOMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*
COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES* *Vented appliances refer to natural draft appliances equipped with a barometric draft regulator or Category I appliances equipped with a draft
More informationState of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety
5.3.1A(2) Page 1 of 2 State of ALASKA, Weatherization Assistance Program Technical Support Document Combustion Safety This document is intended to support in detail the Combustion Safety Test Report. The
More informationBPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST
BPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST 1. Pre-Inspection Homeowner Interview (3 minutes) A. Turn on & zero CO Meters. Determine ambient CO : B. Record Outside Temperature: C. Homeowner interview:
More informationRetrofit Installer-Mechanical
Retrofit Installer-Mechanical Lesson Plan Section 1: Gas FurnaceFundamentals Learning Objectives By attending this session, participants will: Know the components of a gas furnace Understand the basic
More informationEquipment Specifications and Required Information Quantity Rebate
Rebate not to exceed 50% of the cost of equipment. Recycling rebates qualify for the entire rebate, regardless of the recycling cost. Equipment must be purchased or recycled in 2016. Installed equipment
More informationAddress Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances
Rebate not to exceed cost of high efficiency equipment. Equipment must be purchased or recycled in 2015. Installed equipment must be on cooperative's lines. Submit the documentation listed below no later
More informationBUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS
BUILDING PERFORMANCE INSTITUTE TECHNICAL STANDARDS FOR THE BUILDING ANALYST PROFESSIONAL Health and Safety All technicians performing diagnostic tests, inspections, or installations, must have access to
More informationPro Eco-Energy. Home Assessment
Pro Eco-Energy Home Assessment Prepared for: Prepared by: Pro Eco Energy Andrew Aliferis PO Box 445 Scotland, PA 17254 717-446-0575 ABOUT THIS REPORT Your in-home evaluation was conducted on 2/12/2013.
More informationIndiana WX Oil Furnace Inspection Guide
Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up:
More informationHOME PERFORMANCE ENERGY ANALYSIS
Certifed Home, Termite, Green & Commercial Inspectors HOME PERFORMANCE ENERGY ANALYSIS ON 1234 ANY STREET; PHOENIX, AZ PREPARED FOR: JOHN DOE JANUARY 23, 2009 BY: PAUL A. FURMAN, P.E., LEED-AP Hire the
More informationBALTIMORE GAS AND ELECTRIC COMPANY (BGE) Home Performance with ENERGY STAR Program. Rebate and Incentive Instructions
Rebate and Incentive Instructions Contents Application Instructions... 1 Rebate Requirements Summary... 2 Comprehensive Home Energy Audit (CHEA) Rebate... 4 Air Sealing and Insulation Rebate... 4 Air sealing...
More informationENERGY AUDIT DATA COLLECTION/ HEALTH & SAFETY ASSESSMENT
ENERGY AUDIT DATA COLLECTION/ HEALTH & SAFETY ASSESSMENT CLIENT JOB# CLIENT PHONE NUMBER(S) DWELLING TYPE CLIENT NAME SITE BUILT MULTI 1-4 ADDRESS MOBILE MOBILE DUPLEX # OF OCCUPANTS SHELTER OTHER OWNER
More informationEnergy Efficiency Practices for the Low- Income Population
Energy Efficiency Practices for the Low- Income Population Donald Fournier Managing Director SEDAC University of Illinois Residential Energy American homes use almost 25% of the energy consumed in the
More informationRESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com This session will address the basics of combustion and the latest
More informationData Collection/Health & Safety Assessment/Educational Material Notification
NEW JERSEY DEPARTMENT OF COMMUNITY AFFAIRS Division of Housing and Community Resources Data Collection/Health & Safety Assessment/Educational Material Notification CLIENT JOB# CLIENT PHONE NUMBER(S) DWELLING
More informationCode verification sign-off
Code verification sign-off Following is a list of the most common manufactured home code non-compliant items found in used or altered manufactured homes. These are only the most commonly found items and
More informationEXISTING MULTIFAMILY OREGON CASH INCENTIVES. Standard Incentives SAVE MONEY AND ENERGY NOW AND FOR YEARS TO COME.
MULTIFAMILY Standard Incentives EXISTING MULTIFAMILY OREGON CASH INCENTIVES SAVE MONEY AND ENERGY NOW AND FOR YEARS TO COME. EFFECTIVE JUNE 2018 INCENTIVES ARE SUBJECT TO AVAILABILITY AND MAY CHANGE. Energy
More informationNew Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011
New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011 Customer: Street: City: Zip: Phone: (Home): ( ) - Phone: (Work): ( ) - Owner: Yes No/ Name: Phone: ( )
More informationEnergy Saver 101: Home Energy Audits
Energy Saver 101: Home Energy Audits Take the first step to improving your home s energy efficiency: get a home energy audit. What is a home energy audit? A home energy audit helps you pinpoint where your
More informationCombustion Safety Testing: What we learn from Standards and Research. Objectives. Objectives 2/24/2016
Combustion Safety Testing: What we learn from Standards and Research Better Buildings Better Business Conference March 2016 Experience. Innovation. Results. Confiden al 2015 Objectives Identify differences
More informationAnticipating Depressurization Issues Due to Air Tightness and Ventilation Needs
Anticipating Depressurization Issues Due to Air Tightness and Ventilation Needs Rebecca Olson Neighborhood Energy Connection Duluth Energy Design Conference February 26 th, 2013 Duluth, MN Learning Objectives
More informationNatural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )
Natural Gas Appliance Testing Action Guidelines (n ESA/Low Income 5 ) The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take in the event
More informationLow-Impact Remodeling
Low-Impact Remodeling Mike O Brien, OSD Green Building Specialist Building envelope Solar heating & cooling Space heating Water heating Ventilation Moisture control Combustion safety Performance testing
More informationFAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98166 October 26 th, 2017 We have
More informationVentilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.
Ventilation ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce /NDCommerce /NDCommerce /NDCommerce /NDCommerce WHATS NEW IN ASHRAE 62.2 2016 Controls (Override) Shutoff for maintenance
More information2015 NATURAL GAS EFFICIENCY REBATE APPLICATION
2015 NATURAL GAS EFFICIENCY REBATE APPLICATION 1. CUSTOMER INFORMATION (please print) SECTION 1 MUST BE FILLED OUT COMPLETELY OR APPLICATION WILL BE RETURNED Customer Name E-mail Address Home Phone Number
More informationPART 5: HVAC & DHW SYSTEMS
PART 5: HVAC & DHW SYSTEMS Building Science Review Building Science Review: HVAC & DHW Systems This document will help you: Correctly answer all parts of the HVAC Systems section in the Home Energy Score
More informationRESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION
RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION DL Bohac * Center for Energy and Environment, Minneapolis, MN USA ABSTRACT Extensive
More informationEnergy problems in small apartment buildings
Energy problems in small apartment buildings Uneven heating and drafts, window condensation, complaints about odors and burned out lamps these are common problems in four-unit to eight-unit apartment buildings.
More informationCombustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO
Combustion Safety RESNET Conference San Antonio, TX February 27, 2006 Presented by Rich Moore Lightly Treading Energy & Design Denver, CO Goals of this session Recognize the need for combustion safety
More informationObjectives. Home Performance Diagnostics with the House of Pressure (Part 1) How can Pressure effect Building Performance?
Home Performance Diagnostics with the House of Pressure (Part 1) Objectives Learn the basic rules of air flow and differences Begin to be able to recognize building problems related to airflow and differences
More informationWAP Pressure Diagnostics Procedure. Page 1
WAP Pressure Diagnostics Procedure Page 1 This document is meant to describe an overall procedure that will allow a WAP Energy Assessor to conduct a thorough blower door / manometer guided diagnostic assessment
More informationElectric Heat Inspection Form Revised September 2012
Client name: Address: Primary Heat Source: Auxiliary Heat Application: Heat Pump Information: Equipment Information Electric Electric Heat Inspection Form Revised September 2012 Audit Existing furnace
More informationHome Energy Assessment Report
Home Energy Assessment Report Prepared for Prepared by Nathaniel Dick 50 Washington St Westborough, MA 01581 Assessment Date Powered by Conservation Services Group Assessment Summary About Your Home Year
More informationHome Performance Analysis
395 National Drive Suite 15 Burtonsville, MD 2866 www.efficienthomellc.com 31-476-768 FAX: 31-476-7717 info@efficienthomellc.com Home Performance Analysis ENERGY AUDIT REPORT Prepared For: Matthew Lesko
More informationSmall Building Program Design Phase Assistance
Small Building Program Design Phase Assistance Customer s Facility/Project Location XXXX/YYY, MA Project Team (if selected) Contact Firm Phone Email Customer: Electric PA: Gas PA: PAs s Technical Consultant:
More informationWatson Home Inspection Services, LLC.
Cover Page Watson Home Inspection Services, LLC. Property Inspection Report 16466 Olalee Rd, Apple Valley Ca., 92307 Inspection prepared for: Jesse Owens & Zona Owens Agent: Ofir Andrews - Hamilton Landon
More information2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# for Prescriptive Energy Code Compliance
2015 RESIDENTIAL ENERGY CODE WORKSHEET BPA LOG# f Prescriptive Energy Code Compliance FIRST, meet the minimum Washington State Energy Code Requirements: MEDIUM DWELLING UNIT: 3.5 POINTS All dwelling units
More informationInspector FX Field Forms
Inspector FX Field Forms PROPERTY / CLIENT Customer File # Customer Contact Address City, St, Zip Phone Fax Email Inspection location Send report to Phone Neightborhood Main entry faces East North South
More informationRESNET National Conference New Orleans, LA. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, LA. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com This Presentation s Goals What to look for during a Home Performance
More informationAir Change, Ventilation, and Dehumidification for Multi-family Buildings
Air Change, Ventilation, and Dehumidification for Multi-family Buildings Armin Rudd Corp www.buildingscience.com for Acknowledgments: USDOE Building America Joseph Lstiburek, Peter Baker, Kohta Ueno--BSC
More informationHabitability Guidelines
Habitability Guidelines for Relocated Manufactured Homes dced.pa.gov/mh @PADCEDnews Purpose The purpose of these habitability guidelines is to provide a reasonable level of assurance that the relocated
More informationWays to Save. Energy efficiency tips to help you lower your monthly power bill. 1 Ways To Save
Ways to Save Energy efficiency tips to help you lower your monthly power bill 1 Ways To Save 2 Ways To Save Money Saving Advice Jackson EMC is a good resource to use in your energy planning. We can show
More informationRESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO
RESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO rgalenmoore1@msn.com Effective insulation and air sealing treatments can make a huge difference
More informationEnergy Upgrade California Home Upgrade Offered by The Energy Network
Energy Upgrade California Home Upgrade Offered by The Energy Network Who is The Energy Network? Local government organization Created by the California Public Utilities Commission Provides resources and
More informationTips on Saving Energy & Money at Home
Tips on Saving Energy & Money at Home Hot Winter Tips Find the Leaks, Then Weatherize You can save 10% or more on your energy bill by reducing the air leaks in your home. Test your home for air leaks.
More informationAsurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -
Cover Page Property Inspection Report Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski - Date of Inspection: 3/28/2017 Time: 2:00 Age of Home: Built 1999 Size: 2015 Weather: 50 Overcast.
More information2015 MECHANICAL CODE REQUIREMENTS
2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per
More informationSummary of Changes to the ESA Program California Installation Standards Manual dated December 2014 (as of 10/30/17)
Definitions multiple Added Air Sealing/Envelope Defines term used in MHR section 1. Revised definition for Gas Meter Set Assembly In accordance with utility policy 2. Added Mechanical Inlet and Nonmechanical
More informationYour Energy Management Partner
Your Energy Management Partner Operations and Maintenance (O&M) Spot-Check Procedure: This document is intended to provide HFA staff with the knowledge and guidelines to ensure that proper operations and
More informationWeatherization Standards and Field Guide for Pennsylvania February 2011 Edition Published for the
Weatherization Standards and Field Guide for Pennsylvania February 2011 Edition Published for the Department of Energy Weatherization Assistance Program and the Pennsylvania Department of Community, Economic
More informationHome Energy Audit. 170 Security Circle Suite 104 Athens, GA
170 Security Circle Suite 104 Athens, GA 30605 706-248-0821 Home Energy Audit Customer: John Customer Auditor: Brian Young BPI# 5015564 Address: 0000 Deer Run Drive Date: 08/17/2010 Type: Single Family
More informationCanadian Property Inspections
Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.
More informationFAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98270 June 14 th, 2017 We have
More informationFAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98296 May 10 th, 2017 We have coordinated
More informationThe Most Effective Energy Upgrades for Existing Buildings
The Most Effective Energy Upgrades for Existing Buildings Use Compact fluorescent Light Bulbs Replace your incandescent light bulbs with compact fluorescent light bulbs (CFLs), or even better; with LED
More informationRW West Consultants. Property Inspection Report
Cover Page RW West Consultants Property Inspection Report 98122 Inspection prepared for: Faira Date of Inspection: 4/27/2017 Time: 9:00 AM Age of Home: 1992 Size: 3000 Weather: Cloudy 45 degrees Order
More informationFAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98075 May 18 th, 2017 Thank you for your interest in this Faira Certified home. We have coordinated
More informationAre you warming up with space heaters?
Are you warming up with space heaters? As the temperature drops, many families may use portable electric space heaters to help warm their homes. The Electrical Safety Foundation International warns that
More informationAxiom Property Inspections
Cover Page Axiom Property Inspections Property Inspection Report 868 Wally Avenue, Henderson NV, 89178 Inspection prepared for: John Doe Agent: David Lawson - Axiom Inspection Date: 8/12/2010 Time: 2:30
More informationIncentives Existing Multifamily Properties
Information Sheet PI 320M Effective January, 2018 Energy Trust is offering the following incentives for existing multifamily properties: Incentive offers are subject to change. Complete Energy Trust incentive
More informationWhole House Action Guidelines
for Pacific Gas and Electric Company's (PG&E) Whole House Rebate Progam 12/23/2011 The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take
More informationRW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -
Cover Page RW West Consultants Property Inspection Report 98028 Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: - Date of Inspection: 5/26/2017 Time: 9:00 AM Age of Home: 2012 Size: 2480
More informationFAIRA TRANSPARENCY REPORTS. March 14 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 4106 38 th Ave SW, Seattle, WA
More informationFAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 418 17th St SE, #13A, Auburn, WA
More informationSCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE
SCHEDULE OF S Penalty Fees. The fee for construction work performed before securing permit(s), where required, may be charged a fee of TWO TIMES THE COST OF THE PERMIT (S). Building Fee Schedule Residential
More informationIntroductions HERS Industry HERS Ratings ACCA Standard 12 Resources
Abe Kruger 2013 RESNET Conference abe@krugersustainabilitygroup.com 215/385-6891 Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources www.krugersustainabilitygroup.com 1 HERS Rater & Trainer/QAD
More informationEASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. What is condensation?
EASY$ TIP SHEETS Energy Advice Saving Yukoners Money Quick Links What is condensation? Condensation on windows Hidden condensation Causes and solutions Controlling humidity in your home Humidity and Condensation
More informationSecond Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:
Second Revision No. 3-NFPA 31-2015 [ Section No. 10.5.1 ] 10.5.1* Oil burners, other than oil stoves with integral tanks, shall be provided with some means for manually stopping the flow of oil to the
More informationInsulate your exterior walls. Air seal and insulate your attic
Energy Fitness Plan For: Test Report 416 Testing rd, Minneapolis, MN 55343 By: Kyle Shannon, Dan May Date: Nov 01, 2013 YOUR ENERGY FITNESS SCORE 0 INEFFICIENT HOUSE ACTION NEEDED 41 100 32 11 3 13 EFFICIENT
More informationCHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES
CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES Where to Install Pipe Temperature Sensors for Freeze Protection 1 WHICH PIPES SHOULD I MONITOR FOR FREEZE
More informationHome Performance Science
Home Performance Science Symptoms of a Sick House Too hot/too cold rooms Respiratory problems Headaches/nausea Smoky fireplace Foggy windows Stuffy air and lingering odors Peeling paint Constant dust problems
More informationSUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017
SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017 The Residential Energy Code Worksheet is a tool to help you plan your energy code needs for new or remodeled homes,
More informationHome Inspection Report
Home Inspection Report Your New Address, Your Town, USA Inspection Date: Inspection Date Prepared For: New Homeowner Prepared By: Complete Home Inspectors P.O. Box 1104 Smiths Station, Alabama 36877 Phone:
More information10/26/2016. Funding. Conservation Applied Research and Development Program (CARD)
Funding Conservation Applied Research and Development Program (CARD) 1 Study goals What are the energy-using characteristics of Minnesota s MHs? How much energy do MHs use? What energy-saving opportunities
More informationBPI 1200 and ASHRAE Standards
BPI 1200 and ASHRAE Standards For the HPwES Program in 2016 December 16, 2015 Audio Connection To connect to audio: 1. Click the Call Using Computer button to use this setting. a. To confirm connection,
More informationSection 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS
WATER HEATER STORAGE GAS Lead Paint Risk Factor NONE TABLE OF CONTENTS PART 1: INSTALLATION REQUIREMENTS FOR CONVENTIONAL HOMES... 1 WATER HEATER REPAIR... 1 1. APPLIANCE REPAIR... 1 WATER HEATER INSTALLATION...
More informationFAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98198 Thank you for your interest in this Faira Certified home. We have coordinated the efforts
More informationFAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98065 Thank you for your interest in this Faira Certified home. October 12, 2017 We have
More informationFAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017
608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98122 Thank you for your interest in this Faira Certified home. April 28 th, 2017 We have
More informationRESNET Rating Field Inspector Field Evaluation Form
RESNET Rating Field Inspector Field Evaluation Form This form shall be used for 3 mentored inspections and the final field evaluation. Forms and photos must be kept for a minimum of 3 years. RESNET may
More informationSUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM
SUMMARY 1234 Main St.Severn 21144 Buyer Name 07/18/2018 9:00AM Henry Toman MD License 32391 1st American Home Inspection, LLC 443-685-4062 henrytoman61@gmail.com The summary is meant to organize the defects
More informationEnergy Design Conference 2016 Test Protocols & Results: Airport Sound Program and Building America Field Tests
Energy Design Conference 2016 Test Protocols & Results: Airport Sound Program and Building America Field Tests Dave Bohac, PE Center for Energy and Environment MSP Airport Sound Program Weatherization
More informationAUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS
AUTOMATIC MAKE-UP AIR DAMPER WITH READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY Page 1 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Installation
More informationVentilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings
Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings Site Address Contractor Contractor Email Contractor Phone Date SECTION A Square feet * Number of bedrooms Ventilation Quantity
More informationSIGNIFICANT CHANGES TO MINOR WORK AND ORDINARY MAINTENANCE
SIGNIFICANT CHANGES TO MINOR WORK AND ORDINARY MAINTENANCE Pursuant to adoption in the March 5, 2018 New Jersey Register, the requirements for minor work and ordinary maintenance have changed. This document
More informationCustomized Energy Audit Report
Customized Energy Audit Report PREPARED FOR: Tom Homeowner 1234 First Street Anytown, OH 45050 Homeowner, Tom PREPARED BY: Clint Cravens Building Performance Expert Email: ccravens@greenstreethome.us Dear
More informationQuick Fixes Home Energy Checklists
Quick Fixes Home Energy Checklists Today Turn down the temperature of your water heater to the warm setting (120-degrees Fahrenheit). You'll not only save energy, you'll avoid scalding your hands. Start
More informationTHE SUSTAINABILITY INSTITUTE
THE SUSTAINABILITY INSTITUTE Founded in 1999 Focus on Capacity Building Home to Multiple Programs CharlestonWISE & The Impact Project Energy Conservation Corps Pathways to a Green Economy Connects you
More informationInspection Checklist Mechanical Rough in
Property Owner Name: Property Address: Permit Number: Inspectors Name: Review Date: Permits and Plans 1. Job address is posted in a visible location. (R319.1) 2. Permit and approved plans are on site and
More informationTheHeritage COLLECTION SINGLE SECTION HOMES
TheHeritage COLLECTION SINGLE SECTION HOMES Standard Features INTERIOR Drape Package - Living Areas only 2 Mini-Blinds T/O Shaw Moxy 13 oz Carpet with 5# Rebond Pad & Tack Strip Congoleum No Wax Vinyl
More informationThe Unplanned Impacts On Houses By Powered Attic Ventilators
The Unplanned Impacts On Houses By Powered Attic Ventilators John J. Tooley Jr., Natural Florida Retrofit Bruce Eugene Davis, Advanced Energy Corporation Applied Building Science Center 1994 ABSTRACT It
More informationAn Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010
An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010 Putnam County Planning & Development Services Building & Zoning Division Compliance Section PO Box 1486 Palatka, FL 32178 1486 Office
More informationBUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS
BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by
More information