CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION
|
|
- Erika Beatrice Strickland
- 5 years ago
- Views:
Transcription
1 CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION David R. Grupp Director of Research Robinson Industries, Inc. 400 Robinson Drive Zelienople, PA 16063
2 CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION David R. Grupp Director of Research Robinson Industries, Inc. 400 Robinson Drive Zelienople, PA Abstract Coal pulverizer mills are utilized in many coal fired power generation facilities across the country and around the world. These coal mills utilize centrifugal exhaust fans to induce and transport a very abrasive air and coal particulate mixture from the mill to the burner for combustion in the boiler. Historically, the centrifugal fan design used in these applications has been a reliable, but low efficiency paddle wheel type design commonly known as a whizzer wheel. Recently work has been conducted on an improved fan design intended to replace or retrofit the existing coal mill exhauster fan assembly within the constraints of the existing pulverizer mill. The new fan was designed to provide increased volume flowrate through the mill, increased efficiency in operation, and extended wear life. However, a unique erosion problem was experienced in the first application of the new centrifugal fan design. By utilizing state of the art numerical analyses in order to study the fan performance and erosion characteristics of the subject fan unit, the erosion problem was solved. The purpose of this paper is to discuss the original design and development of the high efficiency, backward curved, centrifugal exhauster fan and highlight the application of advanced computational fluid dynamic (CFD) analyses used to identify and solve the subsequent erosion problem encountered on the installed fan unit. Introduction and Background Since the advent of deregulation in the power industry, coal fired power plant facilities have experienced various changes including the type and quality of coal utilized for combustion. In addition, the increase in demand for power at various generating facilities has resulted in the need for increased plant performance and efficiency. The transport of the air / coal mixture is essential in providing the proper rate of combustion in the burner. With an increase in fan performance, an increase in overall mill capacity could be achieved, thus resulting in a higher rate of combustion. This, of course, led to the desire for a new fan design capable of increased performance and efficiency compared to the existing paddle wheel design.
3 Development of High Efficiency Exhauster Robinson Industries was originally contacted by a large utility company for the purpose of replacing the existing whizzer wheel type coal mill exhauster fan with a new, higher capacity fan design. Another important consideration for the new design was to reduce the wear and erosion of the equipment in order to minimize costly downtime and maintenance on the multiple units in operation at the plant. In order to ensure proper application of the new fan design with respect to aerodynamic performance and efficiency, Robinson recommended that laboratory testing of a prototype fan unit be conducted. In addition, flow visualization studies were proposed to predict the most likely areas for high velocity coal particulate impingement and erosion in the fan rotor and casing to aid in the design of wear protection for the fan unit. Prototype Aerodynamic Performance Testing per AMCA Air performance testing of the new fan design was essential in establishing the necessary performance characteristics of the fan unit. The fan rotor had to be designed to provide high aerodynamic efficiency and yet have inherent erosion resistant characteristics as well. The first step in the design process was to verify the original rated performance of the existing paddle wheel type fan unit. This baseline test would enable comparison to the new design with respect to performance and wear. Figure 1 illustrates the initial test set up of the original paddle wheel type or whizzer wheel prototype fan unit. Figure 1. AMCA Air Performance Test Set Up Existing Fan Unit
4 The goal of the new design, as established by the customer, was to increase the capacity of the mill by increasing the volume flowrate of the fan by 10% of the original rated flow. The increase in capacity results in an associated increase in fan static pressure of 21% assuming the performance characteristics of the system follow a parabolic resistance curve. Based on the desired increase in performance and previous test work at Robinson, it was determined that the retrofit fan design would require a new rotor and housing combination to achieve the objective. Air performance testing was conducted in accordance with AMCA inside Robinson s AMCA Accredited laboratory per Figure 7, Outlet Duct Test Set Up Pitot Traverse in Outlet Duct (AMCA ). Prototype scale models of the existing fan unit and various new designs were fabricated, assembled, and tested on a calibrated dynamometer set up. Results were then corrected to full size, full speed conditions using performance conversion procedures per AMCA Complete geometric correspondence was achieved during fabrication in order to ensure linear proportionality and angular similarity. The ratio of material thicknesses and internal clearances were taken into account as well. Complete fan dynamic or flow similarity was achieved by running the prototype units at a rotational speed high enough to generate a Fan Reynold s Number above the minimum threshold value of 3 x 10 6 to eliminate any apparent changes in efficiency due to size effects between the model fans and the full size fan units. In addition, Tip Speed Mach Parameter requirements were satisfied within AMCA allowable limits to provide proper scaling from model test results to full size. Compressibility effects were also considered in the calculations and conversion procedures. Various design iterations were made to optimize the rotor blade design for the required specific speed (i.e. volume and pressure characteristics). A backward curved blade shape was finalized based on the highest efficiency achievable with a blade shape that would provide resistance to erosion and coal particulate impact damage. In addition, the housing design was optimized for the new rotor design, while maintaining the original inlet and outlet connection dimensional constraints and foundation bolting pattern. This consideration ensured that the new, retrofit fan design would be able to be installed into the existing exhauster position in the mill. Figure 2 illustrates the measured prototype fan performance for both the existing paddle wheel type fan and the retrofit backward curved type fan design developed at Robinson. Results shown on the curve are corrected from lab model size to full size conditions. Additional corrections are made for speed, density, and temperature and are labeled on the graph for reference. From the comparison curve, it is evident that the new design provides a substantial increase in volume and pressure along the entire operating range of the fan performance curve with an associated reduction in brake horsepower. In addition, peak static efficiency of the BC fan design was measured to be 12.8% higher than the original whizzer wheel design.
5 40 35 Prototype Test Fan Performance Comparison Curve Existing PW Type vs. Retrofit BC Type Results Corrected to Conditions of: 1780 RPM, 70 Deg. F, Lb/Ft 3 Density 64" Dia. BC Type 61-5/8" Dia. PW Type Fan Static Pressure (In-H20) Brake Horsepower (BHP) Volume (CFM) Ps - BC Type Ps - PW Type BHP - BC Type BHP - PW Type Figure 2. Prototype Fan Performance Curve Comparison Evaluation of System Effects on Installed Retrofit Fan Unit After completion of AMCA 210 air performance testing on the new BC fan design, further evaluation of the as-installed fan performance was still required. Since the unit was designed to be retrofit into the existing installation, additional considerations for inlet and outlet system effects had to be addressed to verify the actual installed fan / system performance. Two potential system effects to consider were a 90 degree canted elbow at the inlet of the fan and a reducing, offset transition connecting the discharge of the fan unit to the downstream ducting. In order to quantify the effects of these components, the original AMCA 210 test set up for the BC fan was modified with the addition of the inlet elbow and the offset discharge transition. Additional testing was conducted on the prototype fan unit and a reduction in peak efficiency of 8.8% was measured. As expected, the fan brake horsepower remained constant, but the volume pressure characteristic curve was reduced due to the presence of the inlet and outlet components. The major reason for deficient performance may be attributed to the sharp, 90 degree turn at the inlet of the fan unit, which is believed to cause a distorted inlet velocity distribution into the fan rotor. Figure 3 illustrates the modified test set up for the evaluation of installed system effects. Figure 4 shows a fan performance comparison curve between the AMCA 210 (open inlet) test and the as-installed fan performance curve with system effects as predicted by laboratory prototype testing.
6 Figure 3. Evaluation of Installed System Effects 90 Degree Canted Elbow at Inlet Prototype Test Fan Performance Comparison Curve Prediction of Installed Fan Performance with System Effects Results Corrected to Conditions of: 1780 RPM, 150 Deg. F, Lb/Ft 3 Density 64" Dia. BC Type Fan Static Pressure (In-H20) Brake Horsepower (BHP) Volume (CFM) Ps - BC Type w/ SE Ps - BC Type BHP - BC Type w/ SE BHP - BC Type Figure 4. Fan Performance Curve Comparison System Effects
7 Erosion and Wear Studies Using Paint Injection Method In order to ensure the success of the fan rotor design from the standpoint of erosion and wear, flow visualization studies were also conducted to characterize the localized wear patterns in the blade channels and throughout the entire rotor. High velocity impingement of paint particles injected into the rotating fan wheel can help assist in qualitatively analyzing the design of the rotor and identifying areas with a tendency for wear or build-up to occur. Areas of high relative velocity in the fan rotor tend to become heavily coated while low relative velocity, low flow regions of the rotor and blade channels typically do not become coated with paint particles. Figure 5 illustrates the paint injection process as conducted in Robinson s laboratory on one of the design iterations of the high efficiency, backward inclined fan unit. From the photo, high relative velocity areas of particle impingement appear on the leading edge of the blades and are concentrated toward the back plate of the rotor. In addition, inlet dust deflectors are positioned on the web plate between the blades on the fan rotor. These deflectors help to establish particulate flow through the blade channels without impacting either the leading or trailing edge of the blades. The actual design and position of these deflectors was optimized for the final rotor design by conducting multiple paint injection test iterations on the final rotor design. Figure 5. Flow Visualization / Erosion Studies through Paint Injection Process
8 Particulate path lines coming off of the deflectors can also be seen on the web plate in between blades. One caveat in the paint injection test process is that the hub and hubcone areas tend to become heavily coated with paint. However, typically only light wear and erosion is experienced by these components in actual coal mill exhauster installations. In addition, the size, mass, distribution, and inertial properties of the atomized paint spray are not the same as the actual coal particles entrained into the airstream, which again reinforces the qualitative nature of the test. Design of Wear Protection on Exhauster Rotor Based on the results of the paint injection erosion studies conducted and previous experience with fans on other erosive applications, wear protection was designed to adequately protect the fan wheel from the abrasive nature of the coal particulate. 90% alumina ceramic was selected as the material of choice for general wear protection on the fan rotor based on cost and proven performance in highly abrasive fan applications. Areas in the rotor identified through testing as high relative velocity and likely impingement areas were treated with tungsten carbide as the most critical wear locations on the fan rotor. These areas included the leading edge of the blades, trailing edge of the blades (blade tips), and inlet dust deflectors. Figure 6 illustrates the wear protection applied to the first production backward curved fan rotor. Figure 6. Production Fan Rotor Wear Protection Alumina Ceramic and Tungsten Carbide
9 Operation of Installed Retrofit BC Design Fan Unit Following fabrication, testing, and assembly of the fan rotor, housing, and inlet piece, the first BC design coal mill exhauster retrofit fan unit was put into service. Verification of aerodynamic fan performance was conducted on the unit to determine if the production fan unit met the required performance as specified by the customer and predicted from laboratory prototype testing. Field air performance testing was conducted in accordance with AMCA , Field Performance Measurement of Fan Systems. The results of the test were determined to be satisfactory and closely agreed with the laboratory prototype test of the model fan unit. After 20 weeks in operation, the fan unit was inspected during a routine plant shutdown. The fan rotor and housing appeared to be in excellent condition with very little wear or erosion. Figure 7 illustrates the condition of the fan rotor after operation for 20 weeks conveying a mass flowrate of 395-lb/min coal dust at approximately 13,000 ACFM volume flow rate. Figure 7. BC Fan Rotor Inspection After 20 Weeks in Operation Following the 20-week trial period of operation, the customer determined that an additional increase in fan performance would be desirable to further improve mill capacity. Laboratory testing was again conducted to modify the fan rotor for an increase in diameter. Fan performance and paint injection test results were documented and reviewed by Robinson and the customer.
10 The originally supplied spare fan rotor was modified at the Robinson plant to increase the effective diameter from 64 to 68. This size was determined to be the maximum possible tipout diameter based on the customer specified allowable clearance to the fan housing cut-off. After 50 weeks in operation, the fan unit with the modified rotor was re-inspected to examine the overall mechanical condition of the equipment and to observe the wear on the rotor and other components. During this inspection, some wear was observed on un-lined portions of the rotor back plate. Normal wear was observed on all other areas of the fan rotor and fan housing sides and scroll wrap. Figure 8 illustrates the fan inspection after 50 weeks of operation. Figure 8. BC Fan Unit Inspection After 50 Weeks in Operation Discovery of Blade Erosion Problem on BC Fan Rotor Following the 50-week inspection on the fan unit, the coal mill was run under normal operating conditions for some additional period of time. During an unscheduled shut down, the exhauster fan unit was inspected as a matter of standard procedure. While the fan rotor was being examined, numerous blades were found to have considerable erosion on the ceramic lining and in some cases the base metal of the blades had completely worn through. The location of wear was consistent on all blades with erosion heaviest near the web plate and approximately 4 to 6 inches along the blade from the outside diameter of the rotor. Figure 9 shows the condition of one severely worn blade / liner during this inspection.
11 Figure 9. Severe Blade Erosion Modified BC Fan Rotor Determination of Root Cause of Rotor Blade Erosion Problem With the discovery of the erosion problem, engineers from Robinson, the end user, and the wear protection manufacturer met to discuss possible causes and potential solutions. It was determined that application of the lining material was done in an appropriate and consistent manner as completed on the original rotor. It was also established that the operating conditions of the mill and fan including coal particulate mass flowrate were essentially as expected considering the increase in performance with the larger rotor. Laboratory air performance and paint injection test results were reviewed in order to possibly identify some problem previously not recognized. One theory hypothesized was that the web plate inlet dust deflectors had an inherent design flaw, thus allowing the coal particulate to strike the blade before exiting the blade channel in the modified rotor. However, based on a thorough review of all data available, a root cause of the erosion problem was still not able to be conclusively determined. The one conclusion agreed upon was that the exhauster rotor did not experience extensive erosion until after the tip-out modifications were performed. Computational Fluid Dynamics Analysis of Exhauster Since traditional methods of analysis were not able to yield the basic cause for the blade erosion, Robinson decided to utilize computational fluid dynamics (CFD) to analyze the problem. This advanced, numerical method was recently acquired by Robinson and was not available during the original research and development stages of the backward curved fan design.
12 CFD Model Geometry and Solution Figure 10 illustrates the geometry of the CFD model developed to study the erosion problem. From the figure, the fan inlet ductwork, fan housing, fan inlet piece, fan rotor, and discharge ducting are included in the analysis. Boundary conditions for the model were established in the inlet duct upstream of the 90-degree elbow at the fan inlet and at the exit of the fan discharge ducting prior to entering the coal pipes. Figure 10. CFD Model - Coal Mill Exhauster Fan Geometry Multiple analyses were conducted for various size coal particles based on customer supplied mill operating data available on the actual units. In addition, cases for both the 64 diameter and 68 diameter wheels were conducted for comparison purposes. A uniform velocity profile of 4705 FPM was selected based on the AMCA 203 field measured fan inlet volume and known cross sectional area of the inlet ducting. Figure 11 shows the actual grid element generation for the CFD model. A combination of hexahedral and tetrahedral element types were utilized in the model of close to 1 million individual elements. The fluid dynamics analysis was run with a 3-D, segregated, implicit solver, utilizing the k-e turbulence model and a second order upwind discretization solution scheme. A particle tracking analysis was also conducted to identify and visualize the trajectories of the discreet phase coal particles in the airflow.
13 CFD Model Results 64 Dia. Rotor Figure 11. CFD Model Grid / Element Generation Figure 12 shows contours of static pressure inside the exhauster fan rotor for the 64 diameter (original) design. From the graphic, an area of high static pressure appears at the trailing edge of one blade in the fan rotor. The presence of the pressure anomaly in the rotor is explained by the interaction of the rotating fan wheel and the static housing cut-off location in the exhauster. Figure 12. CFD Model Contours of Static Pressure in 64 Dia. Fan Rotor
14 Figure 13 illustrates velocity vectors relative to fan wheel rotation. From this graphic, low relative velocity recirculation inside the fan rotor may be observed in the same area as the high static pressure cell. The reverse flow was found to be present only in the blade channels adjacent to the fan housing cut-off, meaning each blade would be subjected to this phenomena as it traveled through one revolution. The following graphic is a snapshot of the rotor frozen in time. Figure 13. CFD Model Relative Velocity Vectors in 64 Dia. Fan Rotor Figure 14 shows particle traces of the discrete phase coal particles of diameter as they travel through the fan rotor. The particle size corresponds to 325 mesh and was specified by the customer as the particle size of most interest to analyze. For reference, approximately 80% of the coal particles pass through 200 mesh in this particular application. Figure 14. CFD Model Coal Particle Trajectories in 64 Dia. Fan Rotor
15 From the particle trace graphic, a number of interesting phenomena were observed. First, the coal particles do not enter the fan rotor in a uniform, distributed manner. This would be expected, considering the 90-degree elbow at the fan inlet. Second, the inlet dust deflectors appear to be doing an adequate job in directing particles through the blade channels without impacting the leading or trailing edges of the blades. This was important in that it validated the correct design of the inlet dust deflectors in protecting the blades from high velocity impingement of coal particles. It also eliminated the deflectors as the source of the erosion problem due to an inherent design flaw in the rotor. Finally, in the area near the cut-off, some particles were observed to exit the fan rotor and then actually re-enter the rotor and impact an adjacent blade channel due to the interaction of the wheel and housing. Most of these impacts, however, were located at the very tip of the rotor blade in an area lined with tungsten carbide. CFD Model Results 68 Dia. Rotor Figure 15 shows contours of static pressure inside the exhauster fan rotor for the 68 diameter (modified) design. From this graphic, the same area of high static pressure appears in the rotor near the housing cut-off. However, due to the larger rotor size, reduced internal clearance, and higher performance, the static pressure cell is more predominant than the original 64 dia. rotor. Figure 15. CFD Model Contours of Static Pressure in 68 Dia. Fan Rotor Figure 16 illustrates velocity vectors relative to the rotation of the 68 dia. fan wheel. From this graphic, it is evident that the recirculation inside the fan rotor has become much more prevalent and at a much higher velocity. Relative velocities in the are area of impingement on the 64 dia. rotor were approximately 15,000 FPM compared to velocities in excess of 20,000 FPM on the 68 dia. rotor.
16 Figure 16. CFD Model Relative Velocity Vectors in 68 Dia. Fan Rotor Figure 17 shows particle traces of the discrete phase coal particles of diameter as they travel through the 68 diameter fan rotor. From this plot, it may be seen that the coal particles re-enter the fan rotor and strike the blade approximately 4 to 6 inches inside the wheel diameter at almost a 90-degree angle perpendicular to the blade at velocities close to 20,000 FPM. Although the same phenomena was observed on the 64 diameter rotor, the location of impact on the modified rotor occurred inside of the 2 tungsten carbide lining at the blade tip and on the standard ceramic lining. This re-entry of coal particulate due to the fan rotor / housing cut-off interaction was determined to be the root cause of the severe erosion on the blades. Figure 17. CFD Model Coal Particle Trajectories in 68 Dia. Fan Rotor
17 Recommendations Once the erosion problem was identified, a number of ideas were presented to reduce or eliminate the effect of the coal particulate impinging on the blades. Potential solutions such as making housing cut-off modifications and installing deflector plates inside the housing were evaluated, but ruled out due to constraints in the fan geometry, adverse affects on fan performance, or cost of implementation. Finally, it was decided to provide the simplest solution of extending the tungsten carbide lining at the tips of the blades down the blade channel an additional 6 to adequately protect the blades from high velocity coal particulate impact. Conclusion A new, high efficiency, high capacity backward curved fan was designed to retrofit existing coal mill exhauster units. The new design provided increased performance and improved efficiency, however, a serious erosion problem developed on the fan blades following modification of the rotor to provide the maximum possible performance. When standard analysis methods failed to provide an answer to the problem, computational fluid dynamics (CFD) was utilized to visualize the flow and particle dynamics inside the fan rotor and housing. Based on the results of the CFD analysis, the root cause of the severe blade erosion problem was identified. A cost effective solution was then agreed upon and implemented. The 68 diameter rotor has been in operation without interruption since the modifications were made without any evidence of additional severe erosion on the blades of the coal mill exhauster fan rotor. This analytical study of fan performance and erosion is unique in that this approach had not previously been used to solve an industrial fan related erosion problem of installed equipment at a power generating facility. Acknowledgments The author would like to recognize Mr. Samuel B. Toas, Research Engineer, at Robinson Industries, Inc. for development of the computational fluid dynamics models of the subject fan units and subsequent analysis of the aerodynamic and particle tracking results. The author would also like to acknowledge the support of Robinson Industries in the preparation and presentation of this paper at the Welding and Repair Technology for Power Plants, Fifth International EPRI RRAC Conference held on June 26-28, 2002 in Point Clear, Alabama. References 1. ANSI/AMCA Standard Publication , Laboratory Methods of Testing Fans for Aerodynamic Performance Rating 2. AMCA Standard Publication , Industrial Process/Power Generation Fans: Establishing Performance Using Laboratory Models 3. AMCA Standard Publication , Field Performance Measurement of Fan Systems
Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background
Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Siddharth Jain, Yogesh Deshpande, Atul Bokane, Arun Kumar Santharam, and Deepak Babar, Halliburton Abbreviations: Computational
More informationFan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10
Fan Laws Keith Miller Samuel Tepp Associates Paul Cenci, P. E.-Principal Brian England-Principal Basic Terms CFM - Cubic Feet per Minute, volume (amount) of air being moved SP - Static Pressure, resistance
More informationIntroduction to Fans. The Basics of Fan Principles and Terminology
Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream
More informationUnderstanding Fan System Effects
Fan Application FA/101-99 A technical bulletin for engineers, contractors and students in the air movement and control industry. Understanding Fan System Effects The air moving industry uses a common term
More informationModeling and Simulation of Axial Fan Using CFD Hemant Kumawat
Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat Abstract Axial flow fans, while incapable of developing high pressures, they are well suitable for handling large volumes of air at relatively
More informationThe Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan
The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan Manoochehr Darvish Bastian Tietjen Stefan Frank darvish@htw-berlin.de tietjen@htw-berlin.de
More informationFan Selection. and Energy Savings
Fan Selection and Energy Savings Reducing power consumption by minimizing system pressure loss and choosing the right equipment HBy BRIAN MLEZIVA Greenheck Fan Corp. Schofield, Wis. Power Consumption HVAC
More informationCompression of Fins pipe and simple Heat pipe Using CFD
Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages
More informationOPTIMIZING PERFORMANCE IN SPRAY OPERATIONS
OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS CONFIRM THAT YOU ARE USING THE BEST NOZZLES AVAILABLE FOR YOUR OPERATION The nozzle is the heart of your spray operation. They are precision-engineered components
More informationFans: Features and Analysis
Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section
More informationA Novel Approach for the Thermal Management. of PC Power Supply
ISTP-16, 005, PRAGUE 16 TH INTERNATIONAL SYMPOSIUM ON TRANSPORT PHENOMENA A Novel Approach for the Thermal Management of PC Power Supply Fu-Sheng Chuang*, Sheam-Chyun Lin, Jon-Ting Kuo, Chien-An Chou Department
More informationBasic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency
Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency Haiye Lou TurboMoni Applied Dynamics Lab Abstract It is often happened, when a project
More informationICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA
DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA ICONE16-48187 THERMAL CYCLE EVALUATION FOR FEEDWATER HEATER OUT OF SERVICE CONDITION
More informationPerformance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Performance Evaluation and Design Optimization of Refrigerated Display
More informationDevelopment of Large Size Hybrid Fan
Technical Paper Toshihiko Nishiyama Kengo Koshimizu Keiichi Inaba A lot of small fans with three-dimensional, wide chord length, forward swept figure, and/or shroud ring have been developed and manufactured
More informationAir Flow Study inside the Supermarket Refrigeration System
Air Flow Study inside the Supermarket Refrigeration System Sandeep Palaksha Senior CAE Engineer Hussmann Services India LLP #9, Anand s Corner, 2 nd Floor Market Road, Netkallappa Circle Basavanagudi,
More informationDesign And Analysis Of Centrifugal Pump
Design And Analysis Of Centrifugal Pump GUIDED BY: Assistant Professor Jayendra B. Patel PRESENTED BY: Makwana Hardik Modh Hiren Patel Gaurang Patel Dhaval 1 Introduction It Convert the mechanical energy
More informationEffect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower
Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower Kalpesh W. Shirsath 1, S.R. Patil 2, Sumit M. Naik 3 PG Student 1,3, Assistant Professor 2 Department of Mechanical Engineering
More informationLOW-NOX BURNER RETROFIT CHALLENGE
LOW-NOX BURNER RETROFIT CHALLENGE By Craig Lieb Applications Engineer Zeeco, Inc. Rutland, UK Ryan Roberts Project Engineering Manager Zeeco, Inc. Broken Arrow, OK, U.S.A. Ryan Roberts has more than 20
More informationStock Vessels for Improved Quality and Energy Savings
Innovative Mixing of 6%-20% Consistency Stock Vessels for Improved Quality and Energy Savings Marc R. Moseley Manager, Global Pulp & Paper Industry Philadelphia Mixing Solutions, Ltd. Dr. Wojtek Wyczalkowski
More informationEnergy Conservation with PARAG Energy Efficient Axial Flow FRP Fans
PARAG FANS & COOLING SYSTEMS LTD. Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans Registered Office & Works Plot No.1/2B & 1B/3A, Industrial Area No.1 A.B.Road, Dewas 455001 (M.P.)
More informationDevelopment of a Compact High Efficiency Cooling Device for the PA8000 Processor*
Development of a Compact High Efficiency Cooling Device for the PA8000 Processor* Guy R. Wagner Hewlett-Packard Co., Fort Collins Systems Laboratory 3404 E. Harmony Road Fort Collins, Colorado 80525 Phone:
More informationCHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger
CHAM Limited Pioneering CFD Software for Education & Industry CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger PHOENICS demonstration case A CFD model of a cross-flow heat
More informationIndustrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation
Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating
More informationState-of-the-art Developments to Save Energy in Coating Drying
State-of-the-art Developments to Save Energy in Coating Drying Executive Summary Coating drying is expensive. A great deal of energy is needed to effectively evaporate sufficient water to dry the coating.
More informationThe Advantages of Choosing Centrifugal Fans
The Advantages of Choosing Centrifugal Fans Introduction Centrifugal fans are widely used for various commercial and industrial applications today. These fans are popular choices for automotive, heating,
More informationENVIRO UNIT ENGINEERING MANUAL KES SERIES
ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationOptiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.
Optiline Fan Array The optimum number of fans for every application The Optimum in Sound Energy Size Redundancy Reliability Energy Labs was before was cool Introduction Energy Labs was the first manufacturer
More informationEuropean Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces
European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces Rex K. Isaacs, Director of Burner Products, Zeeco USA, LLC Abstract
More informationSelecting the Correct Fan
Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications
More informationNumerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length
Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length HEIMO WALTER Institute for Thermodynamics and Energy Conversion Vienna University
More informationAnalysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine
IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling
More informationTurning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS
Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is
More informationFAN ENGINEERING. Surge, Stall and Instabilities in Fans
FAN ENGINEERING Industrial Fans & Services Information and Recommendations for the Engineer Surge, Stall and Instabilities in Fans Introduction Users of fan systems would like to experience a steady, continuous
More informationCFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5
IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys
More informationGreenJet Transfer Fans
GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018 GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into
More informationImproving Fired Heaters Reliability using Inclined Firing Technology
Improving Fired Heaters Reliability using Inclined Firing Technology 1 Operating and Reliability Issues High tube metal temperatures Localized flame impingement Fired heaters have burners that are fired
More informationGlossary of Terms Laboratory & Fume Exhaust Fans
Glossary of Terms Laboratory & Fume Exhaust Fans ACTUATOR, 2-POSITION SPRING RETURN A spring return actuator generally used to control the isolation dampers below the fans. This actuator allows for fully
More informationIn-Situ Roll Balancing A Revolutionary Method for Improving Dryer Section Performance
In-Situ Roll Balancing A Revolutionary Method for Improving Dryer Section Performance J Michael Robichaud, P.E. Bretech Engineering Ltd 70 Crown Street, Saint John, NB Canada E2L 3V6 email: Mike.Robichaud@bretech.com
More informationwe make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)
we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established
More informationModeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room
Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Y. Momoi 1, K. Sagara 1, T. Yamanaka 1 and H. Kotani 1 1 Osaka University, Graduate School of Eng., Dept.
More informationAPPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2
APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2 1 Zeus Numerix Private Limited, Pune, India 2 Pankaj Dharkar & Associates, Mumbai, India
More informationHigh-efficiency Turbo Chiller (NART Series)
67 High-efficiency Turbo Chiller (NART Series) Wataru Seki* 1 Kenji Ueda* 1 Jyou Masutani* 2 Yoichirou Iritani* 2 Turbo chillers are widely used for district heating and cooling, heat storage (regeneration)
More informationHumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems
HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems HumidiPack CF HumidiPack CF offers the performance of HumidiPackPlus without the need of jacketing steam on pressurized steam applications.
More informationRefining and Petrochemical Heater trouble shooting
Refining and Petrochemical Heater trouble shooting 16 Oil&Gas Special Report TEXT 260417.indd 16 Heater trouble shooting Refining and Petrochemical It s Getting Hot in Here! Zeeco solves the mystery of
More informationUsing FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels
Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels Jack R. Mawhinney, P. Eng., FSFPE Javier J. Trelles, Ph.D. Authors & acknowledgement J. R. Mawhinney
More informationLow Profile Layout Guidelines
Low Profile Layout Guidelines Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity.
More informationHeat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling
Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,
More informationAGN 088 Air Flow and Cooling
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 088 Air Flow and Cooling COOLING AIR FOR AN ALTERNATOR Both open air ventilated alternators and enclosed alternators
More informationNEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY
NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY USING A NEW CONCEPT IN MOISTURE SENSING AND CONTROL BY DRYING TECHNOLOGY, INC A New CD Warp Control System For the Corrugating Industry Introduction:
More informationA. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:
SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL
More informationMODULATING CONTROL OF LOW NO X BURNERS
MODULATING CONTROL OF LOW NO X BURNERS ABSTRACT Manufacturers of today s wall-fired low NO X burners (LNB) recommend a single-position secondary air volume control for in-service burners. Air register
More informationCUSTOM PRODUCTS AND SERVICES GUIDE
NEW YORK BLOWER COMPANY (800) 208.7918 nyb.com CUSTOM PRODUCTS AND SERVICES GUIDE Why New York Blower Company The New York Blower Company is a full service fan manufacturer offering a complete array of
More informationMAS AIR SYSTEMS, LLC (724) mas-fan.com PRODUCTS AND SERVICES GUIDE
MAS AIR SYSTEMS, LLC (724) 652-1367 mas-fan.com PRODUCTS AND SERVICES GUIDE Why MAS Air Systems MAS Air Systems, LLC, is a full service fan manufacturer offering a complete array of centrifugal and axial
More informationENGINEERING LETTER 4
ENGINEERING LETTER 4 The New York Blower Company 7660 Quincy Street, Willowbrook, Illinois 60521-5530 TEMPERATURE AND ALTITUDE AFFECT FAN SELECTION INTRODUCTION Fan performance changes with the density
More informationCOMPANY MANAGEMENT TREE
COMPANY MANAGEMENT TREE Executive Director General Manager Personal Officer Marketing Officer Production Purchase Quality Logistics Field Security Service Marketing Executive Engineers Officers Controller
More informationCFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology
IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology
More informationCASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton
CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION Ken Singleton Manager KSC Consulting LLC, Bristol VA ksingleton@vibrationconsulting.com Bob McGinnis. P.E. McGinnis Engineering LLC, Kingsport
More information[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Numerical Study on Solar Water Heater using CFD Analysis S.Eswaran *1,M.Chandru 2,M.Vairavel 3, R.Girimurugan 4 *1 Assistant professor,
More informationDFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.
DFE T ECHNOLOGY As components become smaller, component mixes become more diverse, and board densities continue to increase, the processes of packaging, interconnection, and assembly are challenging the
More informationCentrifugal Fans, Non-Overloading, Backward Inclined
BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination
More informationHigh Performance Diesel Fueled Cabin Heater. Abstract
High Performance Diesel Fueled Cabin Heater Tom Butcher and James Wegrzyn Energy Science and Technology Division Building 526 Upton, N.Y. 11973 Brookhaven National Laboratory Abstract Recent DOE-OHVT studies
More informationSTUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER
STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER WULANDANI, D., K. ABDULLAH, E. HARTULISTIYOSO Department of Agricultural Engineering, Faculty of Agricultural
More informationWater Mist-Based Fire Suppression Modelling of an Office Space Scenario
Water Mist-Based Fire Suppression Modelling of an Office Space Scenario Hai Jiang, Vaidya Sankaran, Med Colket, May Corn United Technologies Research Center Kati Laakkonen Marioff Corporation 14th International
More informationSeries V Layout Guidelines
VT0, VT1, VF1,VF0,VC1 & VCA Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity. Other
More informationAnalysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant
Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET
More informationEXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER
EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER Cinzia Buratti, Elisa Moretti and Michele Urbani Department of Industrial Engineering, University of Perugia, via G. Duranti 67, 06125 Perugia,
More informationSmoke Layer Height and Heat Flow through a Door
Smoke Layer Height and Heat Flow through a Door 2018 Smoke Layer Height and Heat Flow through a Door In this tutorial you will simulate a growing fire in the corner of a 5m x 5m room. The room has a 1m
More informationDisplacement Ventilation
Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution
More informationAnalysis of ventilation system for a microwave assisted drying unit
Analysis of ventilation system for a microwave assisted drying unit ADRIAN-GABRIEL GHIAUS 1, DANIEL POPESCU 2 and CALIN CIUFUDEAN 3 1 Thermal Engineering Department Technical University of Civil Engineering
More informationSelecting Fans and Determining Airflow for Grain Drying and Storage
Proceedings of the Integrated Crop Management Conference Proceedings of the 1993 Integrated Crop Management Conference Dec 2nd, 12:00 AM Selecting Fans and Determining Airflow for Grain Drying and Storage
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.0 STUDY OF AEROACOUSTIC PHENOMENONS AT DUCTED COOLING
More informationEffect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2006 Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor
More informationQualification of Fan-Generated Duct Rumble Noise Part 1: Test Facility
8, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). ESL-PA-8-6-8 Published in Vol., Part. For personal use only. Additional reproduction, distribution,
More informationImproving Air Handler Efficiency in Houses
Improving Air Handler Efficiency in Houses Iain S. Walker, Lawrence Berkeley National Laboratory ABSTRACT Although furnaces, air conditioners and heat pumps have become significantly more efficient over
More informationMechanical Engineering Laboratory
Mechanical Engineering Laboratory MEE 416 Professor H. Ezzat Khalifa Syracuse University http://lcs.syr.edu/faculty/khalifa/mee416/ MEE416 1 A. Experiment 1 Air-Conditioning: Air-side Experiment 0031 Link
More informationStudy of air circulation inside the oven by computational fluid dynamics.
The 8 th International TIChE Conference (ITIChE 2018) "Designing Tomorrow Towards Sustainable Engineering and Technology" @A-ONE The Royal Cruise Hotel Pattaya, Thailand, November 8-9, 2018 Study of air
More informationGuidelines for Optimizing Drying and Blow-Off Operations
Experts in Technology Nozzles Control Analysis Fabrication Guidelines for Optimizing Drying and Blow-Off Operations Changing your approach can slash operating costs and increase efficiency Jon Barber,
More informationFLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University
FLIGHT UNLOADING IN ROTARY SUGAR DRYERS By P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN James Cook University Paul.Britton@jcu.edu.au, Phil.Schnieder@jcu.edu.au, Madoc.Sheehan@jcu.edu.au Keywords: Drying,
More informationCML Northem Blower Inc. Air Movement Equipment
CML Northem Blower Inc. Air Movement Equipment For years Northern Blower has been designing and manufacturing fan equipment for commercial and industrial applications. Product integrity and outstanding
More informationModeling water-mist based suppression of 34 GJ car-deck fires using FDS
Modeling water-mist based suppression of 34 GJ car-deck fires using FDS S. Li, R. Acharya, M. Colket, V. Sankaran, G. Poncia United Technologies Research Center L. Torpo Marioff Corporation March 1 st,
More informationFAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan
FAN TYPES In order to cover a wide range of applications, fans are manufactured in a variety of type. They can be classified under three general types : (a) Centrifugal, (b) Axial and (c) Mixed flow. Table
More informationCENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:
Pumps DOE-HDBK-1018/1-93 CENTRIFUGAL PUMPS CENTRIFUGAL PUMPS Centrifugal pumps are the most common type of pumps found in DOE facilities. Centrifugal pumps enjoy widespread application partly due to their
More informationSPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS
SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification
More informationIntroduction Airflow and filtration area General design practices Cleaning system
FACING THE CHALLENGE JOHN RENNOCKL, CLARCOR INDUSTRIAL AIR, USA, PROVIDES HELPFUL HINTS FOR THE DESIGN EVALUATION AND OPERATION OF COAL MILL DUST COLLECTORS. Introduction Today s regulatory climate has
More informationSandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2
A CFD Analysis of Smoke Movement in Steel Industry Sheds Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2 Mechanical Dept. Dr.Babasaheb Ambedkar College of Engineering and Research,
More informationFinite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener
Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener Mohan Kumar G R Assistant Professor, Department of Automobile Engineering, New Horizon
More informationPulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities
Pulse Jet ASTEC PULSE JET BAGHOUSE for Asphalt Facilities ASTEC PULSE JET BAGHOUSE FOR ASPHALT MIXING PLANTS Astec baghouses deliver superior performance and efficiency, while helping your plant meet
More informationPerformance Analysis of Centrifugal Fan by CFD
Performance Analysis of Centrifugal Fan by CFD Jaykumar Gajjar #1, Prof. Chetan Vora *2, Prof. Vipulkumar Rokad $3 # PG student Mechanical Department, Kalol Institute of Technology and Research Centre
More informationAPI MANUAL OF PETROLEUM MEASUREMENT STANDARDS
API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Chapter 22 Testing Protocols Section 1 General Guidelines for Developing Testing Protocols for Devices Used in the Measurement of Hydrocarbon Fluids Type Testing
More informationEmergency Ventilation System Design - Preliminary Report Shishir Gupta
Emergency Ventilation System Design - Preliminary Report Shishir Gupta (shishir@mechartes.com), Abstract The existing stations and tunnels of Metro Railway, Kolkata are not equipped with effective emergency
More informationINFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS
INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS Staņislavs GENDELIS, Andris JAKOVIČS Laboratory for mathematical modelling of environmental
More informationcompressed air or left to consume air even when the associated production machine has been turned off.
SToP operating BlIND USE A FlowMETER By Ron Marshall for the Compressed Air Challenge c Participants of Compressed Air Challenge s Fundamentals of Compressed Air Systems seminars are usually surprised
More informationAXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS
Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS FPAC FPMC FPDA CATALOG AX351 JULY 2001 WWW.TCF.COM
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationBoiler Basics. Design and operation
Boiler Basics Design and operation A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under
More informationSPRAY DRYING SYSTEMS INC.
SPRAY DRYING SYSTEMS INC. Spray Drying Systems, Inc. Cover photos: (large photo) This co-current, parallel flow spray dryer produces a 300 micron average particle size with no buildup. This demonstrates
More informationWater Pumps. turbo-hydraulic pumps, positive-displacement pumps.
WATER PUMPS Water Pumps Water pumps are devices designed to convert mechanical energy to hydraulic energy. All forms of water pumps may be classified into two basic categories: turbo-hydraulic pumps, positive-displacement
More informationFan Performance and Selection. Overview
Fan Performance and Selection References Burmeister, L.C., Elements of Thermal-Fluid System Design, Prentice Hall, 1998. ASHRAE Handbook: HVAC Systems and Equipment, 1992. Overview Common fan types: centrifugal
More information