4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

Size: px
Start display at page:

Download "4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs"

Transcription

1 Section 1: Parts List 1-50 Flex PVC pipe / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 4 - Female slip/female slip unions 2 - Female slip/fpt union 6 - Male slip/ Female slip elbows 8 - Female slip/female slip elbows 2 - Suction fitting assemblies 1-3/4 HP Circulating Centrifugal Pump / 2 " Tees 2 - Female slip couplers / 2 " hole saw w/ 1/4" drill bit 1 - Jet tool 1-4oz Can of PVC Cement 1-4oz Can of PVC Cleaner / 2 " Male slip plugs 2 - #10 Wing nut plugs 4 - #11 Wing nut plugs 4 - Clear Gaskets Page 1 of 6 Section 2: Placement Considerations The 3/4hp, 220v jet pump needs to be installed at the foot of the front panel, since it will receive its electrical supply from the heater controller (see Figure 3). The electrical cord, which is pre-wired to the pump, plugs into port P1 (orange) on the heater controller. Please remember that drainage or water diversion drain from the front panel is required. Important notice: If your pool or equipment will be subjected to freezing temperatures, special consideration must be given to the jet system in order to avoid freezing of the plumbing lines. Your heater/controller is programmed to automatically circulate the jet plumbing lines four times a day. This circulation reduces the likelihood that the plumbing lines will freeze. Once your pool s installation is complete and the panels are in an enclosed space, additional insulation of the siding material will help keep the warm air radiating from your pool panels in the enclosed space, which is where both your jet pump and jet plumbing lines are located. Having your jet plumbing line run within the space of your bottom flange of your panels is necessary for proper protection from freezing. Additionally, the heater controller comes equipped with a smart winter mode (SWM). When the SWM is enabled, the system will automatically turn the pump on to ensure that there is warm water moving through the plumbing lines. If you believe that these measures will be insufficient to prevent your jet plumbing lines from freezing, please call our Customer Service Department.

2 Section 3: Installation Instructions Page 2 of 6 Jet Supply Jet Suction Jet Pump Figure 1 Jet Suction Figure 2 Jet Supply Thru-Wall Installation 1. As per the Endless Pools Owner s Manual, the hydrotherapy jet suction thru-wall fittings will have been installed by this point (as detailed in Section 11. Thru-Wall Connections Part 1 or Section 13. Thru-Wall Connections Part 2). The suction plumbing assembly must now be installed so that you can continue filling the pool. Refer to Figure 1 of this for the plumbing configuration. Make sure to install a FPT x female slip ball valve onto each suction thru-wall fitting. Ideally the 1-1/2 Tee is centered between the fittings, although this is not necessary. When this plumbing assembly is complete, close the ball valve (this will allow you to continue filling the pool). 2. Continue filling the pool, as per the Endless Pools Owner s Manual. One the water level is 3 below the lowest jet fitting, cut the hole in the liner for this fitting.

3 Page 3 of 6 3. Temporarily secure the jet bodies and bulkheads to the pool. This will allow for accurate measuring for the 1/2 pipe. Cut lengths of the 1/2" PVC pipe for the air supply to each jet. The air pipes for the lower jets may require elbows to clear the jets and piping above. Once installed, the open top of the air supply must be sufficiently above the water line to prevent spill over. The pipe should be terminated 1/4" below the top flange of the pool panel. The 1/2" air supply tubes should be cemented to the jet bodies first, in an inverted position, with the jet internals removed, to prevent dripping of PVC cement or cleaner into the air passages. Once you have all of the 1/2 pipe cut and glued into their respective jet bodies remove the jets from the pool wall. Make sure to note the position of each jet. 4. Now, permanently install the jet bodies. A small bead of silicone should be placed on both sides of each gasket. Place the clear gasket over the jet bulkhead. Wrap Teflon tape around the threads of the bulkhead. The white gasket should go between the liner and panel on the inside of the pool. Another small bead of silicone on the face of the jet body and seat the jet body against the pool wall. Tighten the bulkhead into the jet body. Use the provided jet tool to tighten the bulkhead. Make sure not to over tighten the bulkhead as it can crack. Plumbing Installation 1. Cut lengths of the 1 1 / 2 " PVC pipe provided to connect to each of the four jets. Three 1 1 / 2 " T's and one elbow should be fabricated to provide a supply piping manifold to coincide with the four jet locations. From each of these four fittings extends 1 1 / 2 " PVC to a union. From the unions, connect to each jet with 1 1 / 2 " PVC and an elbow (lower jets use male slip-female slip street elbows, upper jets use a nipple cut to length and a female slip-female slip elbow). The side of each jet opposite where the supply is connected at the bottom will require a plug. The unions allow each jet to be installed separately either before or after the supply piping manifold is assembled. 1/2" Rigid PVC Jet Body Glue Plug Point (Repeat for all 4 Jet Bodies) 1/2" 90 deg Elbow Male Slip x Female Slip 90 deg Elbow Female Slip x Female Slip Union Piping Manilfold Flexible PVC Female Slip x Female Slip 90 deg Elbow Hydrotherapy Jet Supply (Supplied by the Hydrotherapy Jet Pump) Female Slip x Female Slip x Female Slip Tee 2. Cement all PVC slip connections following the cement manufacturer's recommendations. 3. Check the 1/2" air supply pipes to make certain that all four are 1/4 below the top flange of the pool wall. Extend or cut these tubes as required. 4. With the four jets and the suction fitting installed, the ball valves and remaining piping back to the jet pump can be installed. Union fittings have been provided on each side of the jet pump to facilitate its removal should service ever be required. The pump will come with the electrical cord pre-wired. The pump should be placed behind the front panel, close enough to the heater controller so that it can be plugged in. The clearance behind finish skirting should be considered when plumbing the jet pump. The jet pump may have to be raised slightly to allow the pump to be placed as close to the pool wall as possible.

4 Page 4 of 6 Section 4: Jet Operation The cord (with attached plug) that has been pre-installed on the jet pump will be installed into the P1 connection on the heater controller. Jet Pump Connection The jets can be turned on by pressing the pump button on the keypad once then, press it a second time to turn off the jets. Before operating the hydrotherapy jets, make certain that both ball valves are open and the plug in the suction fitting has been removed. The protective suction strainer should installed prior to running the jet. It is extremely important that strainer be screwed into the suction fitting assembly. The jet pump will automatically turn on for approximately 1 minute four times daily. This purge cycle prevents water from stagnating inside the jet plumbing lines. The jet pump will also automatically turn on when the heater-controller is in Smart-Winter Mode (SWM). The heater-controller will enter SWM when the ambient temperature around the heater-controller approaches freezing. SWM protects the plumbing lines of the pool from freezing. The closer the temperature is to freezing, the more frequently the pump will come on. SWM indicator on the keypad will be illuminated when the system is in Smart Winter Mode

5 Page 5 of 6

6 Page 6 of 6

Hydrotherapy Jets (Remote Water Quality System)

Hydrotherapy Jets (Remote Water Quality System) Page 1 of 6 Parts List (_) - 50 Roll of Flex PVC pipe 1-3/4 HP Circulating Centrifugal Pump 1 25 Roll of Flex PVC pipe 4-1 1 / 2 " Tees 2-1 1 / 2 " Ball Valves 2 - Female slip couplers 4-1/2" 90 degree

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007 Assembly- and Usermanual Rainmaker Code No. 99-97-1729 GB Edition: 09/2007 Table of contents Page I 1 Overview and system specifications.................................. 1 1.1 Purpose of Evaporative

More information

PolyMax H2-24 Dutch Bucket System

PolyMax H2-24 Dutch Bucket System 11234 PolyMax H2-24 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. 2017 FarmTek All Rights

More information

Installation, Operation, and Troubleshooting Manual1. Bill Wallace By Wallace Marine Servies, Inc.

Installation, Operation, and Troubleshooting Manual1. Bill Wallace By Wallace Marine Servies, Inc. By Wallace Marine Servies, Inc. Clean Your Engine Room And Bilge The Easy Way Bill Wallace 843-693-4336 villmarine@tds.net www.willyvac.com Installation, Operation, and Troubleshooting Manual1 NOTES Table

More information

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions Tools you might need for proper installation Galvanized Nails or Screws - For Units with a Tiling Flange Four Foot Level Shims Caulking Gun Screw Gun Adhesive Thank you for purchasing the Praxis AirBath

More information

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference. FOR THE RECORD You should record the model and serial numbers, which can be found on the back of the unit, for future reference. Warranty: 18 mo. on unit and 1 year on check valve assembly Model: The Ozone

More information

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2 Professional Series Chemical Feed System Model # 22152-02 US Patent No. 6,752,930 B2 Product Manual SureWater Technologies, Inc. The Solution X-2 Model # 22152-02 Table of Contents 1. Installation Instruction

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

Installation, Operation, and Troubleshooting Manual1. Bill Wallace By Wallace Marine Services, Inc.

Installation, Operation, and Troubleshooting Manual1. Bill Wallace By Wallace Marine Services, Inc. By Wallace Marine Services, Inc. Maintain Your Equipment The Easy Way Bill Wallace 843-693-4336 info@willyvac.com www.willyvac.com Installation, Operation, and Troubleshooting Manual1 NOTES Designed and

More information

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / 27-009, 27-010, 27-015, 27-020 IMPORTANT INFORMATION UNATHORIZED CHANGES OR ALTERATIONS TO ANY LINCOLN PORTABLE VACUUM SYSTEM WILL AUTOMATICALLY

More information

AquaBlox Water Matrix

AquaBlox Water Matrix quablox Water Matrix Installation Instructions & Owner s Manual Step-by-step installation Instructions for the following quablox Water Matrix pplications: { Pondless Waterfalls { RainXchange Rainwater

More information

Parts & Material Included

Parts & Material Included O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer

More information

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR PUMP 88 PUMP PARTS BREAKDOWN REF # Order # Mfr # Description 1 NEP4 AC 348 Lid Knobs NEP AC 380 Strainer Lid 3 NEP6

More information

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions 215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...

More information

Acrylic Claw Foot Tub

Acrylic Claw Foot Tub Acrylic Claw Foot Tub Wrench or socket Drill & Bits Parts Recommended 2-2 x12 boards 4 Lag Bolts 4 Flat Washers Be sure to re-inforce the floor before securing tub. We recommend 2-2 x12 s securely fastened

More information

ENCLOSED UNIT TECHNICAL MANUAL Items # &

ENCLOSED UNIT TECHNICAL MANUAL Items # & R ENCLOSED UNIT TECHNICAL MANUAL Items #91163-00 & 91164-00 The Green Earth II Enclosed Unit is a modular, locking dispensing system that allows the user to dispense chemicals safely. It also has the flexibility

More information

PolyMax H1-10 Dutch Bucket System

PolyMax H1-10 Dutch Bucket System 112529 PolyMax H1-10 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. STK# DIMENSIONS 112529

More information

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance

More information

Installation Instructions PRO SERIES

Installation Instructions PRO SERIES Installation Instructions PRO SERIES If you are a plumber installing this unit, please leave this owners manual & warranty card with the owner when you finish the installation. Thank You! DO NOT USE THIS

More information

AQUARITE DELUXE Model: HW Installation Manual

AQUARITE DELUXE Model: HW Installation Manual AQUARITE DELUXE Model: HW205930 Installation Manual Table of Contents Diagrams. 1 Tools Needed for Installation. 1 Notice to Installers. 2 Packing List. 2 Hinge Assembly. 2 Drain assembly Information.

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

HotLine Internal Sewer Pipe Heater Installation Manual

HotLine Internal Sewer Pipe Heater Installation Manual HotLine Internal Sewer Pipe Heater Installation Manual Prevent Frozen Pipes For Good... No Digging. No Wrapping. No Problem! (877) 881-2980 HotLine Internal Pipe Heater Sewer Line Installation Manual General

More information

Arch Feeder: Installation Manual

Arch Feeder: Installation Manual Arch Feeder: Installation Manual Model #A300N Arch Chemicals, Inc. 1200 Lower River Road, P.O. Box 800 Charleston, TN 37310-0800 Product Stewardship MAKING THE WORLD A BETTER PLACE Arch is committed to

More information

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP 8104 MAXI-PUMP PARTS BREAKDOWN Re f # 1 2 3 4 5 6 7a 7b 8 9 10 11 12 13 14 15 16 2 Part # NEP2134 NEP2135

More information

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F UDX No Sweat Kit instuctions The No Sweat Kit is intended to be used in conjunction with the AET s DB-10-10XC and DB-15-15XC on a 120 or 80 gallon OST (American Water Heater) top or side connect tank.

More information

InterSeptor Centrifugal Separators Operating & Maintenance Manual

InterSeptor Centrifugal Separators Operating & Maintenance Manual General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this

More information

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PIPE DREAMS 96. Aeroponic Garden IMPORTANT: 1 WARNING: BEFORE PUTTING WATER PUMP INTO OPERATION FILL UP NUTRIENT TANK TO TOP OF PUMP. THE PUMP MUST NEVER RUN DRY OTHERWISE, WARRANTY WILL BE DECLINED. READ FILLING INSTRUCTIONS BEFORE USE. Welcome

More information

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP 8308 PUMP PARTS BREAKDOWN Ref # Part # Manf. # Descrip on 1 NEP2134 AC 81361 PUMP LID 2 NEP2135 AC 81396 PUMP LID

More information

HydroCycle Vertical Aeroponic Systems

HydroCycle Vertical Aeroponic Systems HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. *Actual system may differ from system shown. 113593 8' Vertical System (44

More information

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters Operating Instructions for the BBO-1 and BBO-2 Basket Blasters 2101 West Cabot Boulevard Langhorne, PA 19047-1893 www.empire-airblast.com Page 2 Model Number: Serial Number: Date of Purchase: Date of Installation:

More information

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service Owner's Manual (00 Gallon Lawn Service Skid Sprayer) Technical Specifications. Horsepower Recoil Start Engine Roller Cast Iron Pump 0 Gallons Per Minute at 0 PSI Pressure Gauge-Adjustable Pressure Range

More information

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this: Installation Guide Before you assemble your new system, be sure that the following conditions have been met for placement of your softener: Getting Started Level, firm surface, such as concrete, on which

More information

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected. This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected. For further questions contact Glass Water Systems or

More information

SAN JUAN FRESH WATER COOLING SYSTEMS

SAN JUAN FRESH WATER COOLING SYSTEMS SAN JUAN FRESH WATER COOLING SYSTEMS 4.3-5.7 GI VOLVO Block Only Cooling, Mounted Off Engine Kit #V-111 Installation Instructions San Juan Engineering Heat Exchangers provide thermostatically controlled

More information

CAST IRON PEDESTAL TUB

CAST IRON PEDESTAL TUB BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the floor, walls,

More information

Whirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000

Whirlpool Spa PARTS CATALOG MODEL #F ISSUE DATE: 6/95 CATALOG #G766000 The LEXUS TM L.C. Whirlpool Spa PARTS CATALOG MODEL #F9000 ISSUE DATE: /9 CATALOG #G000 CONTENTS Lexus L. C. Reference Discharge Plumbing Discharge Plumbing (Continued) Suction Plumbing Air Line Piping

More information

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these instructions completely and carefully.

More information

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP www.burcam.com 2190 Dagenais Blvd. West LAVAL (QUEBEC) CANADA H7L 5X9 TEL: 514.337.4415 FAX: 514.337.4029 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

1-866-PENNERS

1-866-PENNERS Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision

More information

Installation. Please keep this manual for future reference.

Installation. Please keep this manual for future reference. Installation Tecma Bathroom Anywhere Owner s and Installation Manual Please keep this manual for future reference. Read ALL these instructions before installing the Tecma Bathroom Anywhere unit. Warning

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS HPR SERIES PROOFER/RETARDER MODEL HPR1 ML-132406 30 In. (Standard) ML-132407 50 In. (Standard) ML-132408 63 In. (Standard) ML-132409 83 In. (Standard) ML-132410 96 In. (Standard)

More information

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION I -, 3. -is INSTALLATION AND OPERATION INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM e Coo/ah AMERICAN COOLAIR CORPORATION TABLE OF CONTENTS PAGE I. CONCEPT OF EVAPORATIVE COOLING....2 II. RECOMMENDEDTOOLS......3

More information

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

NOTE: Parts are no longer available for this tool. The manual will continue on the next page. NOTE: Parts are no longer available for this tool. The manual will continue on the next page. ------------------------------------------------- CATALOG NO. 7628 Form No. Z21 0 Date 1-93 High Pressure Power

More information

Acrylic Claw Foot Tub

Acrylic Claw Foot Tub Acrylic Claw Foot Tub Wrench or socket Drill & Bits Parts Recommended 2-2 x12 boards 4 Lag Bolts 4 Flat Washers Be sure to re-inforce the floor before securing tub. We recommend 2-2 x12 s securely fastened

More information

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m)

»»»»»»»»»» Utility pump LAUNDRY TUB PUMPING SYSTEM. CAPACITY: 1400 US GPH HEAD OF: 10 (3m) YEAR 2WARRANTY Utility pump 1/3 HP CAPACITY: 1400 US GPH HEAD OF: 10 (3m) LAUNDRY TUB PUMPING SYSTEM Automatic switch starts motor when water enters in the pump body. Pump body made of Noryl. P trap not

More information

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB TUBS & SURROUNDS FIBERGLASS TUB STANDARD One-piece design for a clean, simple design; left, right, or center drain. 309525 54 x 28 Center White 309530 54 x 28 Center Bone 309535 54 x 28 LH Bone 309540

More information

Technical Specifications Section 1

Technical Specifications Section 1 Technical Specifications Section 1 STANDARD UNIT: MODEL# RH4 Description: Model RH4 is a built-in, 60-gallon, side access bathing tub. Construction: The tub shell is a seamless piece of 3/16" thick fiberglass-reinforced

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS Built-In Dishwasher Dishwashers Write the model and serial numbers here: Model # Serial # You can find them on the tub wall just inside the door or. the lower part of back. Installation Instructions DDW1802W

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS 000 model NO. LSS- 00 GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS Part number and descriptions can be obtained from the illustrated parts list section of this manual.

More information

SWIVEL HEAD WASTE AND OVERFLOW INSTALL

SWIVEL HEAD WASTE AND OVERFLOW INSTALL SKU(s): 921385 SWIVEL HEAD WASTE AND OVERFLOW INSTALL BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts

More information

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345-E

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345-E INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345-E READ CAREFULLY MIRACO A DIVISION OF AHRENS AGRICULTURAL INDUSTRIES, INC. BOX 686 GRINNELL, IOWA 50112 PHONE 641-236-5822 TOLL FREE 1-800-541-7866

More information

Ozone Generator Systems

Ozone Generator Systems PZ2-1 & PZ2-2 - Commercial and Residential Pools & Spas Ozone Generator Systems INSTALLATION GUIDE and OPERATION MANUAL T. O3 NATURAL TECHNOLOGY Reduces Chemical Usage, Improves Sanitation Produces Crystal

More information

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision

More information

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis Installation And Service Manual Watts Pure Water 1725 W. Williams Dr. C-20., Phoenix, Arizona 85027 Phone: 888-774-7405 Fax: 602-588-0356 www.wattspurewater.com

More information

Sources of Graywater

Sources of Graywater What is Graywater? Graywater is wastewater generated from domestic activities such as laundry and bathing, which can be recycled on-site for uses such as landscape irrigation and constructed wetlands.

More information

ACRYLIC PEDESTAL TUB

ACRYLIC PEDESTAL TUB BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the floor, walls,

More information

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708) 1 2 Instructions for Ultrasonic Washer E789 (U.L. Approved) 1. INTRODUCTION The E789 Automatic Ultrasonic Washer automatically performs a cleaning cycle, the major steps of which are: Ultrasonic cleaning

More information

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP Model T00405 REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 450331 Strainer 2 450332 Oil cover "O" ring 3 400447 Impeller 4 450333 Pump casing 5 400450 Oil cover 6 400449 Oil seal 7 400448

More information

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications Installation Instructions Standard Cleanout Requiring Extension 4" example pg 3 3" example pg 5 Installing

More information

HydroCycle Vertical Aeroponic Systems

HydroCycle Vertical Aeroponic Systems HydroCycle Vertical Aeroponic Systems 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. 113700 4' Vertical System (24 Grow Sites) Revision date: 01.10.18 1 Important

More information

STAINLESS STEEL TUB INSTALLATION

STAINLESS STEEL TUB INSTALLATION BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing plumbing fixtures. Signature Hardware accepts no liability for any damage to the faucet, plumbing, sink, counter

More information

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS 148 OLD CONCORD TURNPIKE BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL

More information

The PALlO. Whirlpool Spa PARTS CATALOG. ModelfC Issue Date: Catalog

The PALlO. Whirlpool Spa PARTS CATALOG. ModelfC Issue Date: Catalog The PALlO Whirlpool Spa PARTS CATALOG ModelfC800000 Issue Date: 9 Catalog 0000 CONTENTS Palio Reference Discharge Plumbing Suction Plumbing Air Line Piping Air Blower/Piping Assembly Vent/Drain Assemblies

More information

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1 Introduction The Bottom Feed solar water heater connector is meant to connect solar water heater panels directly to your existing standard water heater. It's main advantages are ease of installation, efficiency,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Web Site: http//www.atomic4.com e-mail: thomas.stevens@cox.net INSTALLATION INSTRUCTIONS INDIGO ELECTRONICS AT-4T THERMOSTAT KIT ATOMIC 4 - ELECTRIC FWC This Indigo Thermostat Kit is designed for use with

More information

Flush Jet Technology. Technical Specifications and Installers Manual

Flush Jet Technology. Technical Specifications and Installers Manual Flush Jet Technology Technical Specifications and Installers Manual INDEX TECHNICAL DATA SHEETS Page3 PRODUCT TECHNICAL DATA SHEET IDENTIFICATION: PART NUMBER PRODUCT NAME JAI6SPL1-XX Body Impressions

More information

Kinetico 2060f OD Sulfur Guard Installation Instructions

Kinetico 2060f OD Sulfur Guard Installation Instructions SAFETY GUIDELINES Read all steps, guides, and rules carefully before installing and using the Kinetico 2060f OD Sulfur Guard. Check your local building and sanitation codes for installation compliance.

More information

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating

More information

HOT WATER BOILER ( MBH)

HOT WATER BOILER ( MBH) GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER (25-200 MBH) Repair PARTS MANUAL P/N 24000523, Rev. C [09/08] TABLE OF CONTENTS I. Circulator Pumps (Optional)...2 II. Burner Assembly...3 III. Boiler

More information

COBRA -300H EXTRACTOR

COBRA -300H EXTRACTOR COBRA -300H EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always

More information

Eureka - Fall Maintenance Crew 2017 List of material for plumbing works for sealift 2017

Eureka - Fall Maintenance Crew 2017 List of material for plumbing works for sealift 2017 Eureka - Fall Maintenance Crew 2017 List of material for plumbing works for sealift 2017 Item Location /Description Ref Qty Price EOB-M23A General Mechanical Division 23 New Garage, Water Heater 1 3/4

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Web Site: http//www.atomic4.com e-mail: thomas.stevens@cox.net INSTALLATION INSTRUCTIONS INDIGO ELECTRONICS AT-4T THERMOSTAT KIT ATOMIC 4 - MECHANICAL FWC This Indigo Thermostat Kit is designed for use

More information

ESSENCIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER

ESSENCIA INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER TO BE KEPT BY THE OWNER TABLE OF CONTENT IMPORTANT SAFETY INSTRUCTIONS...1 PARTS & TOOLS...3 SITE PREPARATION...6 INSTALLATION REMOTE MOUNTING OF TURBINE

More information

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B) Instantaneous Oil-Fired Water Heater Installation Manual MODEL OM-148 (Type B) IMPORTANT THIS APPLIANCE SHOULD BE INSTALLED BY A LICENSED, AUTHORIZED PERSON(S) DUE TO THE NECESSITY OF MAKING ELECTRICAL,

More information

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Light Streams Lighted Bubbler Kit Gunite 2LSLBK (75 strands of Fiber per Bubbler) SAVE THESE INSTRUCTIONS! Fiberstars Light Streams Lighted Bubbler is a very simple device to provide lighted water for

More information

Installation Instructions Air Pump

Installation Instructions Air Pump Important Read all instructions and identify all parts before assembling and installing pump. Observe all local plumbing and electrical codes and the National Electric Code. Electrical installation should

More information

an ISO 9001:2015 Registered Company

an ISO 9001:2015 Registered Company an ISO 9001:2015 Registered Company Mark IV (672001-VHY) 18865 Goll St. San Antonio, TX 78266 Phone: 800-862-6658 Sales: sales@vintageair.com Tech Support: tech@vintageair.com www.vintageair.com 902001-VHY

More information

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual 500 Point Breeze Rd. Flemington, NJ 08822 (908) 782-5800 Phone (908) 782-3380 FAX www.zrpure.com Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual - 1 Contents 1.

More information

#300 & #302 CHLORINEIBROMINE FEEDERS

#300 & #302 CHLORINEIBROMINE FEEDERS #300 & #302 CHLORINEIBROMINE FEEDERS R~M%' Features: No special venting required. Completely enclosed-no escaping gases. Positive external no-clog control valve. Feeder is designed to automatically lower

More information

Rainwater Harvesting &

Rainwater Harvesting & Rainwater Harvesting Rainwater Harvesting Saving from a Rainy Day R ainwater harvesting is the process of diverting, capturing, and storing rainwater for future use. Implementing rainwater harvesting on

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

Installation Instructions Built-In Dishwasher

Installation Instructions Built-In Dishwasher GE Consumer & Industrial Appliances Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

MODEL E

MODEL E www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

model # Order # Xpert-HD 3.8/35 P / DD PD DA

model # Order # Xpert-HD 3.8/35 P / DD PD DA Service MANUAL model # Order # Xpert-HD 3.8/35 P / DD-383537 1.107-108.0 PD4-35324 1.107-096.0 DA-383539 1.107-102.0 8.780-001.0 CONTENTS Exploded View... 4 Exploded View Parts List... 5 S.2 Pump and

More information

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com

More information

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER! 1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based

More information

PZ1, PZ3 & PZ6 Installation Guide

PZ1, PZ3 & PZ6 Installation Guide PZ1, PZ3 & PZ6 Installation Guide PROZONE INTERNATIONAL, INC. Ozone Water Purification Systems INSTALLATION GUIDE Prozone PZ1, PZ3 and PZ6 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.

More information

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1960-66 FORD PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST FORD TRUCK specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967-72 FORD TRUCK CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV) SUBCOURSE EDITION EN5113 5 US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV) US ARMY PLUMBER MOS 51K SKILL LEVELS 1 AND 2 COURSE PLUMBING FIXTURES (PLUMBING IV) SUBCOURSE NO. EN5113 US Army Engineer

More information

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve Operation and Installation

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

Willoughby Industries - Security Products

Willoughby Industries - Security Products TOILET WASTE LOCATION (ECW)- WALL OUTLET (ECF)- FLOOR OUTLET TOILET ORIENTATION (L)- ANGLED LEFT (L)- OFFSET LEFT (R)- ANGLED RIGHT (R)- OFFSET RIGHT (C)- CENTER FIXTURE MOUNTING (OF)- OFF FLOOR (ON)-

More information

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC ISO 9001 Certified Quality Management System SAFETY................................................

More information

BC BRONCOS AIR CONDITIONING UNIT

BC BRONCOS AIR CONDITIONING UNIT BC BRONCOS AIR CONDITIONING UNIT CAUTION If you are not familiar with the principals of air conditioning, have an authorized air conditioning technician evacuate and charge the system. Serious damage to

More information

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual THE BEAUTY OF WATER HOT BATHE Heating Circulation System Installation Instruction Manual For use by Tub Manufacturers or Qualified Service Personnel ONLY. NuWhirl Systems Corp www.nuwhirl.com 95-87-5600

More information