HOME INSPECTION REPORT

Size: px
Start display at page:

Download "HOME INSPECTION REPORT"

Transcription

1 HOME INSPECTION REPORT Kupuna Street Report Prepared For: Tracy De Soto and Emilio De Soto Report Prepared By: Warren d'aquin

2 Page 2 of 27 TABLE OF CONTENTS TABLE of CONTENTS... 2 SUMMARY REPORT... 3 GENERAL INFORMATION... 5 INTRODUCTION AND OVERVIEW... 5 PURPOSE AND SCOPE... 6 GENERAL LIMITATIONS AND EXCLUSIONS... 7 EXTERIOR... 8 ROOF SYSTEM PLUMBING SYSTEM ELECTRICAL SYSTEM INTERIOR APPLIANCES... 24

3 Page 3 of 27 SUMMARY REPORT Note: This analysis is not meant to be technically exhaustive but rather to highlight areas where repairs are needed or areas of long-term future concern relating to maintenance and operation. This summary lists items taken from the main report that we feel need immediate attention or consideration. It is entirely the customer's decision whether or not to include additional items from the main report that they may have concerns about. Further, the Summary is not a substitute for reading and understanding the complete report. EXTERIOR The exterior woodwork and painted surfaces appear in satisfactory condition. No unusual or severe deterioration was observed in the exterior paint/stain finishes. It is important that all exposed wood surfaces are kept well protected to ensure a maximum service life. Subsequent paint maintenance can be carried out as the usual signs of failure such as cracking, peeling or blistering of the painted surface become evident. Typically this would occur at intervals of five to seven years. The driveway and west walkway have cracks in the concrete. The structure appears viable. ROOF SYSTEM The roof cover is aging normally. Some typical indicators of aging (such as minor surface cracking and slightly raised seams) were visible. However, the wear is consistent over the entire surface and typical for a cover this age. There is an area on the roof that has been sealed with roofing compound. The seal has been done professionally. There are a few cracks developing that should be monitored annually and repaired if needed. PLUMBING SYSTEM When reference is made to the type of plumbing, the comment relies on a visual observation, seller statements, the presence or absence of a water bond, and what may be present in the way of notification in the electrical service panel. There is no non-invasive way to determine what is behind a closed wall. For example, when copper plumbing is identified, copper piping protrudes from the walls behind plumbing fixtures. If client requires absolute knowledge as to the type of plumbing throughout the home, then a consultation with a licensed plumbing contractor is recommended. Please note: Inspectors are not required to determine the source of the water supply or operate any valve except water closet flush valves, fixture faucets, and hose bibs. Solar systems, septic systems, wells, filters, conditioners, yard watering systems and fire sprinkler systems are not part of this inspection. Please note: Water stop valves and overflows are not checked for function in the course of a home inspection. Fixtures and trim are observed for function only and not for cosmetic value. There is no seismic bracing on the main water heater. Earthquakes and water heaters: the hazards are obvious. A shifting or toppling water heater poses such a major threat to your safety that most state law requires that these units be braced, anchored or strapped. It is further recommended that the water heater be raised off the ground. An exemption is if the water heater is a short type like in the ohana or if the water heater is located in a dedicated lockable closet.

4 Page 4 of 27 The TPR (pressure relief) valve on the main water heater is frozen closed. Recommend immediate repair or replacement of the valve. Although sprinkler systems are excluded from home inspections, there is a small leak in the valve assembly on the west of the house. ELECTRICAL SYSTEM The smoke alarms were tested and found to be working in the manner intended at the time of the inspection. A representative number of switches and receptacles that are readily accessible are tested for function. Determination of adequacy of electrical panels and current capacity are not within the scope of this report. Low voltage systems, stereos, intercoms, vacuum systems, security systems or other low voltage systems are not inspected and are not within the scope of a home inspection. The main electrical panel cover requires adjustment. The insert must be adjusted so when the breakers are reset, they do not become dislodged from the buss bar as they do now. There is no breaker legend in either panel box. Recommend labeling all breakers. There is no cover plate on the outlet under the ohana kitchen sink. Recommend installing a cover. There is exposed romex in the laundry room and the ohana bedroom closet. Recommend enclosing the romex. The GFCI outlets in the bathrooms are redundant. They are controlled by breakers in the electrical panel box. The outlets should be replaced with standard outlets. Some of the breakers are double tapped. Double tapped wiring is ok if the circuit breaker is designed for two conductors. If a circuit breaker is designed for two conductors, it will say so right on the circuit breaker, and the terminal of the circuit breaker will be designed to hold two conductors in place. Recommend repair. The GFCI breaker in the ohana panel is not seated correctly. Recommend repair. The doorbell does not work. INTERIOR There are minor blemishes throughout the home that are of no real significance other than cosmetic. There are many windows missing screens. Recommend installing screens on all windows. APPLIANCES All appliances were functioning as designed.

5 Page 5 of 27 GENERAL INFORMATION INSPECTION ADDRESS Street: Kupuna Street City: Kailua Kona State: Hawaii Zip: INTRODUCTION AND OVERVIEW INSPECTION DETAILS Inspection Date: Report Date: October 31, 2018 Report Delivered: by web site download Weather Conditions: overcast Temperature: 82 degrees Building Occupied: yes occupied Inspection Limited to: exterior, roof, plumbing, electrical, living spaces, bathroom and kitchen CONSTRUCTION TYPE Construction Style: Single level Construction Material: Single wall construction Residence Type: Single-family dwelling BUILDING DETAILS Date Built: 1981 Approximate Age: 37 years Bedrooms: Four Bathrooms: Three Kitchens: One Supporting Foundation: Slab-on-grade Approximate Area: 2187 Sq. Ft. LEGAL DESCRIPTION TMK: CLIENT INFORMATION Name: Tracy De Soto and Emilio De Soto Address: 6875 Via Valverde City: LaJolla State: California Zip: Cell: tracy@desotosport.com

6 Page 6 of 27 BUYERS AGENT INFORMATION Name: Rebecca Clancy Company: Hawaii Real Estate Group LLC City: Kailua Kona State: Hawaii Zip: Cell: rebecca@rebeccaclancy.com INSPECTED BY Name: Warren d'aquin COMPANY INFORMATION Company: Kona Home Inspections Address: PO Box 1508 City: Kealakekua State: Hawaii Zip: Phone: FAX: warren@konahomeinspections.com Web Site: PURPOSE AND SCOPE It should be noted that a standard pre-purchase inspection is a visual assessment of the condition of the residence at the time of inspection. The inspection and inspection report are offered as an opinion only. Although every reasonable effort is made to discover and correctly interpret indications of previous or ongoing defects that may be present, it must be understood that no guarantee is implied nor responsibility assumed by the inspector or inspection company, for the actual condition of the building or property being examined. Additional information as to inspection standards is included at the end of the report. This firm endeavors to perform all inspections in substantial compliance with the standards of practice of the American Society of Home Inspectors (ASHI). As such, inspectors inspect the readily accessible and installed components and systems of a home as outlined below: This report contains observations of those systems and components that are, in the professional opinion of the inspector authoring this report, significantly deficient or are near the end of their expected service life. If the cause for the deficiency is not readily apparent, the suspected cause or reason why the system or component is at or near end of expected service life is reported, and recommendations for correction or monitoring are made as appropriate. When systems or components designated for inspection in the ASHI standards are present but are not inspected, the reason the item was not inspected is reported as well.

7 Page 7 of 27 GENERAL LIMITATIONS AND EXCLUSIONS The ASHI Standards of Practice are applicable to buildings with four or fewer dwelling units and their garages or carports. They are the bare minimum standard for a home inspection, are not technically exhaustive and do not identify concealed conditions or latent defects or items contained on the Seller s Disclosure form. Inspectors are NOT required to determine the condition of any system or component that is not readily accessible; the remaining service life of any system or component; the strength, adequacy, effectiveness or efficiency of any system or component; causes of any condition or deficiency; methods materials or cost of corrections; future conditions including but not limited to failure of systems and components; the suitability of the property for any specialized use; compliance with regulatory codes, regulations, laws or ordinances; the market value of the property or its marketability; the advisability of the purchase of the property; the presence of potentially hazardous plants or animals including but not limited to wood destroying organisms or diseases harmful to humans; the presence of any environmental hazards including, but not limited to toxins, carcinogens, noise, and contaminants in soil, water or air; the effectiveness of any system installed or methods utilized to control or remove suspected hazardous substances; the operating costs of any systems or components and the acoustical properties of any systems or components. Inspectors are NOT required to operate any system or component that is shut down or otherwise inoperable; any system or component which does not respond to normal operating controls or any shut off valves. Inspectors are NOT required to offer or perform any act or service contrary to law; offer or perform engineering services or work in any trade or professional service other than home inspection. Inspectors DO NOT offer or provide warranties or guarantees of any kind unless clearly explained and agreed to by both parties in a formal pre-inspection agreement. Inspectors are NOT required to inspect underground items including, but not limited to underground storage tanks or other underground indications of their presence, whether abandoned or active; systems or components that are not installed; decorative items; systems or components that are in areas not entered in accordance with the ASHI Standards of Practice; detached structures other than carports or garages; common elements or common areas in multi-unit housing, such as condominium properties or cooperative housing. Inspectors are NOT required to perform any procedure or operation which will, in the opinion of the inspector, likely be dangerous to the inspector or others or damage the property, its systems or components; move suspended ceiling tiles, personal property, furniture, equipment, plants, soil, snow, ice or debris or dismantle any system or component, except as explicitly required by the ASHI Standards of Practice. Inspectors are NOT required to enter under-floor crawlspaces or attics that are not readily accessible nor any area which will, in the opinion of the inspector, likely be dangerous to the inspector or others persons or damage the property or its systems or components. Inspectors are not limited from examining other systems and components or including other inspection services. Likewise, if the inspector is qualified and willing to do so, an inspector may specify the type of repairs to be made. The inspector may also exclude those systems or components that a client specifically requests not be included within the scope of the inspection. If systems or components are excluded at the request of the client they are listed herein.

8 Page 8 of 27 EXTERIOR In accordance with the ASHI standard of practice pertaining to Exteriors, this report describes the exterior wall coverings and trim. Inspectors are required to inspect the exterior wall coverings, flashing, trim, all exterior doors, the stoops, steps porches and their associated railings, any attached decks and balconies and eaves, soffits and fascias accessible from ground level. COMPONENT DESCRIPTIONS Landscaping and lot topography is examined during a residential house inspection as they can have a significant impact on the building structure. It is important that surface runoff water is adequately diverted away from the building. A high water table or excessive ground saturation can also impact septic systems. Even over watering of gardens and shrubbery can have significant effects. A similar impact can result from tree roots growing against the foundation and causing cracking or movement of the structure. It is a standard recommendation that the lot grading slopes away from the building. Grading should fall a minimum of one inch every foot for a distance of six feet around the perimeter of the building. It is also important that tree branches are not permitted to overhang the roof and that all landscaping is kept well pruned and not permitted to grow up against any part of the building. This will help prevent the development of pest and insect problems. BUILDING EXTERIOR Wall Surface Material: wood Condition: satisfactory Wall Trim: wood Condition: satisfactory Entry Door Types: wood panel with glass panel inserts Condition: good condition-no issues SLOPE AND DRAINAGE Direction of Lot Slope: relatively flat Condition: satisfactory condition DRIVES WALKS AND PATIOS Driveway Types: concrete Condition: serviceable condition-aged and worn Walkway Type: concrete Walkway condition: satisfactory Fence and Gate: wood Condition: satisfactory

9 Page 9 of 27 OBSERVATIONS The exterior woodwork and painted surfaces appear in satisfactory condition. No unusual or severe deterioration was observed in the exterior paint/stain finishes. It is important that all exposed wood surfaces are kept well protected to ensure a maximum service life. Subsequent paint maintenance can be carried out as the usual signs of failure such as cracking, peeling or blistering of the painted surface become evident. Typically this would occur at intervals of five to seven years. The driveway and west walkway have cracks in the concrete. The structure appears viable.

10 Page 10 of 27 Inspectors are NOT required to inspect or report on the presence or condition of recreational facilities, outbuildings, seawalls, break-walls and docks, window and door screening, shutters, awnings or similar seasonal accessories.

11 Page 11 of 27 ROOF SYSTEM In accordance with the ASHI standard of practice pertaining to Roof Systems, this report describes the roof coverings and the method used to inspect the roof. Inspectors are required to inspect the roof covering, roof drainage systems, flashings, skylights, chimneys and roof penetrations. COMPONENT DESCRIPTIONS Inspection of the roof includes the cover, flashing, venting, skylights and chimneys. Ideally, the roof is walked. In cases where walking is not possible, observations are limited to what can be seen by the method employed. ROOF COVERING Roof Inspected: by walking the entire surface Roof Slope: pitched Roof Style: hip Roofing Materials: asphalt shingles Material Condition: good condition-no repairs needed GUTTERS DOWNSPOUTS SKYLIGHTS Gutter Downspout Type: none 1 Skylight Type: operable, glass, raised-curb-type Skylight Condition: good condition-no issues 1 The building does not have any gutters. This may result in moisture damage to, or cause unsightly mud spattering of, the exterior siding. It is recommended that gutters be installed.

12 Page 12 of 27 OBSERVATIONS The roof cover is aging normally. Some typical indicators of aging (such as minor surface cracking and slightly raised seams) were visible. However, the wear is consistent over the entire surface and typical for a cover this age. There is an area on the roof that has been sealed with roofing compound. The seal has been done professionally. There are a few cracks developing that should be monitored annually and repaired if needed. Inspectors are NOT required to inspect antennae, interiors of chimneys or flues that are not readily accessible or other installed accessory items.

13 Page 13 of 27 PLUMBING SYSTEM In accordance with the ASHI standard of practice pertaining to Plumbing Systems, this report describes the water supply, drain, waste and vent piping materials and the water heating equipment, energy source and location of the main water and main fuel shut-off valves, when readily viewable or known. Inspectors are required to inspect the interior water supply and distribution systems, all fixtures and faucets, the drain waste and vent systems (including all fixtures for conveying waste), the water heating equipment (vent systems, flues and chimneys of water heaters or boiler equipment), fuel storage and distributions systems for water heaters and/or boiler equipment and drainage sumps, sump pumps and associated piping. COMPONENT DESCRIPTIONS The inspection of the plumbing system includes checking all faucets and fixtures for crossconnection and leaks. Cross-contamination issues are also included as well as pressure, functional flow and functional drainage. SUPPLY AND PIPING Supply and Waste System: municipal supply and waste system Service Piping Size: 3/4-inch Service Piping Type: copper Branch Piping Size: 1/2-inch and 3/4-inch Branch Piping Type: copper Fixtures/Faucets Condition: satisfactory Functional Flow: satisfactory Function Drainage: satisfactory Waste Piping: schedule 40 ABS plastic Condition: no access-not inspected 1 Vent Piping: schedule 40 ABS plastic Condition: No access-not inspected WATER CONTROLS AND DRAINS Main Water Shut Off Location: west exterior of building Main Water Regulator Location: east side of the house WATER HEATER Water Heater Type: one conventional storage tank Water Heater Energy Source: electricity 1 Only visible DWV piping is inspected. The inspection is primarily for leaks and flow. For a more intensive inspection a consultation with a licensed plumbing contractor is recommended.

14 Page 14 of 27 Capacity: 50 Gallons Water Heater Location: laundry room Condition: satisfactory Automatic Safety Controls (TPR) Condition: unsatisfactory condition-defects present ADDITIONAL WATER HEATER Water Heater Type: a conventional storage tank Capacity: 28 Gallons Heater Location: ohana bathroom Condition: satisfactory Automatic Safety Controls (TPR) Condition: satisfactory condition-no defects apparent OBSERVATIONS When reference is made to the type of plumbing, the comment relies on a visual observation, seller statements, the presence or absence of a water bond, and what may be present in the way of notification in the electrical service panel. There is no non-invasive way to determine what is behind a closed wall. For example, when copper plumbing is identified, copper piping protrudes from the walls behind plumbing fixtures. If client requires absolute knowledge as to the type of plumbing throughout the home, then a consultation with a licensed plumbing contractor is recommended. Please note: Inspectors are not required to determine the source of the water supply or operate any valve except water closet flush valves, fixture faucets, and hose bibs. Solar systems, septic systems,

15 Page 15 of 27 wells, filters, conditioners, yard watering systems and fire sprinkler systems are not part of this inspection. Please note: Water stop valves and overflows are not checked for function in the course of a home inspection. Fixtures and trim are observed for function only and not for cosmetic value.

16 Page 16 of 27 There is no seismic bracing on the main water heater. Earthquakes and water heaters: the hazards are obvious. A shifting or toppling water heater poses such a major threat to your safety that most state law requires that these units be braced, anchored or strapped. It is further recommended that the water heater be raised off the ground. An exemption is if the water heater is a short type like in the ohana or if the water heater is located in a dedicated lockable closet. The TPR (pressure relief) valve on the main water heater is frozen closed. Recommend immediate repair or replacement of the valve. Although sprinkler systems are excluded from home inspections, there is a small leak in the valve assembly on the west of the house. Inspectors are NOT required to inspect the connections for clothes washing machines, interiors of flues or chimneys when not readily accessible, wells or well pumps, equipment associated with water storage, water conditioning equipment, solar water heating components or systems, fire sprinkler or irrigation systems or private waste disposal (septic) systems. Additionally, inspectors are not required to operate

17 Page 17 of 27 safety valves or shut-off valves of any kind. We DO NOT determine the quantity or quality of water supplies or whether water supply and waste disposal systems are public or private. ELECTRICAL SYSTEM In accordance with the ASHI standard of practice pertaining to Electrical Systems, this report describes the amperage and voltage rating of the service, the location of the main disconnect and any sub panel(s), the presence of solid conductor aluminum branch circuit wiring and the absence of smoke detectors. Inspectors are required to inspect the viewable portions of the service drop from the utility to the house, the service entrance conductors, cables and raceways, the service equipment and main disconnects, the service grounding, the interior components of the service panels and sub panels, the conductors, the over-current protection devices (fuses or breakers), ground fault circuit interrupters and a representative number of installed lighting fixtures, switches and receptacles. COMPONENT DESCRIPTIONS SERVICE ENTRY Service Drop Type: underground service lateral Condition: satisfactory Meter Location: east side of the residence MAIN DISCONNECT Main Disconnect Type: breaker Main Disconnect Rating: 100 amps Main Disconnect Location: adjacent to main service entrance panel DISTRIBUTION WIRING Wiring Type: non-metallic sheathed cable (Romex) Wiring Conductors: copper Condition: no view-not inspected GFCI Locations: in the home 1 Outlets & Switches Tested: inside the building Polarity & Ground Tested: inside the building SMOKE ALARM DETECTORS Smoke Alarms: No Alarms Found MAIN PANEL 1 GFCI are safety devices that sense a ground fault in an electrical system and cut power to a circuit faster than one s nervous system can react. Modern codes require any branch circuits at kitchen counters, in bathrooms, basements, garages or exterior outlets to be GFCI protected.

18 Page 18 of 27 Service Entrance Panel Location: laundry room Panel Style: breaker system Amperage Rating: 100 amps Voltage Rating: 120/240 volts Condition: satisfactory condition-needs minor repairs Final Service Rating: 125 amps SUB PANEL Sub Panel Location: ohana bedroom Sub Panel Style: breaker system Sub Panel Amperage Rating: 60 amps Sub Panel Voltage Rating: 120/240 volt Condition: satisfactory-with exceptions OBSERVATIONS There are no smoke alarms in the residence.

19 Page 19 of 27 A representative number of switches and receptacles that are readily accessible are tested for function. Determination of adequacy of electrical panels and current capacity are not within the scope of this report. Low voltage systems, stereos, intercoms, vacuum systems, security systems or other low voltage systems are not inspected and are not within the scope of a home inspection. The main electrical panel cover requires adjustment. The insert must be adjusted so when the breakers are reset, they do not become dislodged from the buss bar as they do now. There is no breaker legend in either panel box. Recommend labeling all breakers. There is no cover plate on the outlet under the ohana kitchen sink. Recommend installing a cover. There is exposed romex in the laundry room and the ohana bedroom closet. Recommend enclosing the romex.

20 Page 20 of 27 The GFCI outlets in the bathrooms are redundant. They are controlled by breakers in the electrical panel box. The outlets should be replaced with standard outlets. Some of the breakers are double tapped. Double tapped wiring is ok if the circuit breaker is designed for two conductors. If a circuit breaker is designed for two conductors, it will say so right on the circuit breaker, and the terminal of the circuit breaker will be designed to hold two conductors in place. Recommend repair. The GFCI breaker in the ohana panel is not seated correctly. Recommend repair. The doorbell does not work.

21 Page 21 of 27 Inspectors are NOT required to inspect any remote control devices (unless such device is the only means of control), alarm systems and associated components and controls, low-voltage wiring systems or components or any ancillary wiring, systems or components that are not part of the primary power distribution system. We are also NOT required to measure amperage draw, line voltage or ground impedance. INTERIOR In accordance with the ASHI standard of practice pertaining to Interiors, there is NO requirement for the report to describe any interior components or finishes. Inspectors are required to inspect walls, ceilings and floors, steps, stairways and railings, countertops and a representative number of cabinets, a representative number of doors and windows and the garage doors and automatic garage operators. COMPONENT DESCRIPTIONS ROOM INTERIOR Wall Surface Type: drywall Condition: satisfactory Ceiling Surface Type: drywall and wood Condition: satisfactory Flooring Type: luxury vinyl Condition: good-no issues Kitchen Counter Top Type: granite Condition: good-no issues CABINETS AND COUNTERS Kitchen Cabinet Type: face frame Condition: good-no issues Bathroom Counter Top Type: solid surface resin Condition: good-no issues Bathroom Cabinet Type: face frame Condition: good-no issues Inside Door Type: hollow core wood panel Condition: satisfactory WINDOWS AND DOORS Window Frame Type: aluminum Window Pane Type: single glazed and jalousie Condition: satisfactory OBSERVATIONS There are minor blemishes throughout the home that are of no real significance other than cosmetic.

22 Page 22 of 27

23 Page 23 of 27 There are many windows missing screens. Recommend installing screens on all windows. Inspectors are NOT required to inspect paint, wallpaper or other finish treatments, carpeting, window treatments, central vacuum systems, household appliances and recreational facilities or gymnastic equipment.

24 Page 24 of 27 APPLIANCES COMPONENT DESCRIPTIONS INCLUSIONS & EXCLUSIONS Inspection Will Include: range, refrigerator, dishwasher, food disposer and microwave oven RANGE Range Style: Free standing, self-contained cook top and oven Fuel: Electric Make: Frigidaire REFRIGERATOR Refrigerator Style: French door refrigerator/freezer Make: Frigidaire

25 Page 25 of 27 DISHWASHER Dishwasher Style: Built-in Make: Frigidaire FOOD DISPOSER Food Disposer Type: Electric Make: Insinkerator MICROWAVE OVEN Microwave Oven Type: a built-in type Make: Frigidaire

26 Page 26 of 27 REFRIGERATOR IN OHANA Refrigerator Style: Over-under refrigerator/freezer Make: Frigidaire MICROWAVE OVEN IN OHANA Microwave Oven Type: a built-in type Make: Frigidaire

27 Page 27 of 27 FOOD DISPOSER IN OHANA Food Disposer Type: Electric Make: Insinkerator OBSERVATIONS All appliances were functioning as designed.

HOME INSPECTION REPORT

HOME INSPECTION REPORT HOME INSPECTION REPORT 75-5748 Alahou Street 2F Report Prepared For: Barbara Little Report Prepared By: Warren d'aquin Page 2 of 23 TABLE OF CONTENTS TABLE of CONTENTS... 2 SUMMARY REPORT... 3 GENERAL

More information

Troy's Home Inspection Services LLC

Troy's Home Inspection Services LLC Cover Page Property Inspection Report 33706 Inspection prepared for: Cord King & Patricia King Real Estate Agent: Jane Freel - RE/MA Date of Inspection: 3/4/2017 Time: 8:30 Age of Home: 2008 Size: 3279

More information

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013 Inspection Report Prepared for: Tonia Mann Property Address: 402 Leslie Court McDonough, GA 30253 Date: March 07, 2013 Inspector: Charles Mann Edifice Inspections, Inc. (770) 594-2222 www.edificeinspections.com

More information

Axiom Property Inspections

Axiom Property Inspections Cover Page Axiom Property Inspections Property Inspection Report 868 Wally Avenue, Henderson NV, 89178 Inspection prepared for: John Doe Agent: David Lawson - Axiom Inspection Date: 8/12/2010 Time: 2:30

More information

I. STRUCTURAL SYSTEMS

I. STRUCTURAL SYSTEMS I. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Pier & Beam - Crawlspace Opinion: All exposed areas of the foundation were examined visually. Examination of the foundation was limited to photographs

More information

Inside Out Home Inspections

Inside Out Home Inspections Cover Page Inside Out Home Inspections Property Inspection Report Inspection prepared for: John Doe & Jane Doe Date of Inspection: 5/10/2014 Inspector: Lucas Sargent PO Box 514, Tioga, PA 16946 Phone:

More information

Home Inspection Report

Home Inspection Report Home Inspection Report John Property Address: 123 Main Street Fredericksburg VA 22401 ABI Home Inspections Shannon Lewis PO Box 244 Lively, VA 22507 (804) 724-4468 Virginia Licensed Home Inspector #3380000749

More information

Inspector FX Field Forms

Inspector FX Field Forms Inspector FX Field Forms PROPERTY / CLIENT Customer File # Customer Contact Address City, St, Zip Phone Fax Email Inspection location Send report to Phone Neightborhood Main entry faces East North South

More information

The Ultimate Home Inspection Checklist

The Ultimate Home Inspection Checklist The Ultimate Home Inspection Checklist This checklist is not meant to take place of a professional home inspection and does not contain every aspect of a home inspection. Use the checklist as a guide and

More information

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd. Page 1 of 19 Inspection Report Mr. Happy Property Address: Joseph Poelsterl 450.010220 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Page 2 of 19 Table of Contents Cover Page Table of Contents

More information

Jeff Brown Inspections

Jeff Brown Inspections Cover Page Jeff Brown Inspections Property Inspection Report Vegas NV, 89145 Inspection prepared for: Jim Shen Agent: Lauren Paris - Resolution Realty Inspection Date: 6/13/2013 Time: 10:00 Age: 26 years

More information

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny Cover Page 74804 Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny Inspector: John Crouch License #70001257 Newalla, OK 74857 Phone: 4054815032 Email: john@goodlivinghomes.com

More information

Inspection Report. Jane Doe. Property Address: 123 Anywhere Montgomery AL Central Alabama Property Inspections

Inspection Report. Jane Doe. Property Address: 123 Anywhere Montgomery AL Central Alabama Property Inspections Inspection Report Jane Property Address: 123 Anywhere Montgomery AL 36117 Central Alabama Property Inspections Chip Jones HI-0874 153 Oak Hill Dr Deatsville, Alabama 36022 334-391-4094 123 Anywhere Page

More information

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 17817 80th Ave NE B-3, Kenmore,

More information

Extra Mile Inspection, Inc.

Extra Mile Inspection, Inc. Cover Page Property Inspection Report Inspection prepared for: Jerry and Lynne Richardson Real Estate Agent: Polly Richardson - BHKR Lake Forest Date of Inspection: 3/13/2017 Time: 12 pm Age of Home: built

More information

Watson Home Inspection Services, LLC.

Watson Home Inspection Services, LLC. Cover Page Watson Home Inspection Services, LLC. Property Inspection Report 16466 Olalee Rd, Apple Valley Ca., 92307 Inspection prepared for: Jesse Owens & Zona Owens Agent: Ofir Andrews - Hamilton Landon

More information

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109 1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109 INFRARED VIEW OF HOME Attention: Mr. John Smith SUBJECT PROPERTY The following inspection of a property located at 1710 Anywhere Drive, Montgomery, AL 36109, was

More information

Space Coast Home Inspections LLC

Space Coast Home Inspections LLC Cover Page Property Inspection Report 32908 Inspection prepared for: Melvin Jones & Melvin Jones Real Estate Agent: Anita Uhrmann - Caldwell Banker Date of Inspection: 12/16/2014 Time: 11am Age of Home:

More information

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski - Cover Page Property Inspection Report Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski - Date of Inspection: 3/28/2017 Time: 2:00 Age of Home: Built 1999 Size: 2015 Weather: 50 Overcast.

More information

Inspector Gadget Homes

Inspector Gadget Homes Cover Page Inspector Gadget Homes Property Inspection Report 34105 Inspection prepared for: Mike Cranley Date of Inspection: 3/20/2017 Time: 5:30pm Age of Home: 25 yrs old Size: 3,039 sq ft Weather: Sunny

More information

McKinney Inspection Company

McKinney Inspection Company McKinney Inspection Company Copyright 2013 New Image Software, Inc. All rights reserved. Rev 7/1/2013 Copyright 2013 New Image Software, Inc. All rights reserved General Terminology McKinney Inspection

More information

Cascade Inspection Services, LLC

Cascade Inspection Services, LLC Cover Page Property Inspection Report 97330 Inspection prepared for: John Smith & Sarah Smith Date of Inspection: 6/8/2015 Time: 8:30 A.M. Age of Home: 14 years old Size: 2352 Sq Ft Weather: Sunny Inspector:

More information

Inspection Report 123 My Street Midland, GA

Inspection Report 123 My Street Midland, GA Buying, Selling or Building Your Home Inspection Company ROFESSIONAL INSPECTION SERVICES, LLC P.O. Box 9774 Columbus, GA 31908 706-565-0333 1-866-298-4251 Inspection Report 123 My Street Midland, GA This

More information

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and

More information

Inspection Report. Inspection Date: 1/1/2011. MultiFamily Sample. Property Address: Street Address. City NJ Zip. All In One Home Inspection LLC

Inspection Report. Inspection Date: 1/1/2011. MultiFamily Sample. Property Address: Street Address. City NJ Zip. All In One Home Inspection LLC Page 1 of 70 Inspection Report Inspection Date: 1/1/2011 MultiFamily Sample Property Address: City NJ Zip All In One Home Inspection LLC Joseph W Fleming III - Home Inspector License 24GI00045600 35 1st

More information

Canadian Property Inspections

Canadian Property Inspections Cover Page Canadian Property Inspections Home Inspection Report L9Z-1K4 Inspection prepared for: K.C. Pitman Date of Inspection: 3/6/2017 Time: 3pm Age of Home: 42 Size: 500-1000 Weather: Cloudy, cool.

More information

Inspection Report. Mr. and Mrs. New Owners. Property Address: 123 Nowhere St ANYWHERE FL 32025

Inspection Report. Mr. and Mrs. New Owners. Property Address: 123 Nowhere St ANYWHERE FL 32025 Inspection Report Mr. and Mrs. New Property Address: 123 Nowhere St ANYWHERE FL 32025 Ronald Helton II HI9300 577 SW Thorne Ln Fort White, FL 32038 352-514-1925 HI9300 123 Nowhere St Page 2 of 40 Table

More information

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by: Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include

More information

Home Inspection Report Michael Smith

Home Inspection Report Michael Smith 501 N Semoran Blvd #570709 Orlando, FL, 32807 Home Inspection Report Michael Property Address: 16883 Sample Circle Orlando FL 32819 Ricardo De la Cruz, CMI Certified Master Inspector, HI-8957 Ricardo@pointhomeinspection.com

More information

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS. November 21, 2016 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 7307 22 nd Ave NW, Seattle, WA

More information

Inspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services

Inspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services Inspection Report Mr. XXX Property Address: Sondrio Dr Las Vegas NV 89134 Cover Page Skye Canyon Home Inspection Services Clement Ijidakinro IOS.0002457-RES 8414 W. Farm Road, Suite180 #232 Las Vegas,

More information

Inspection Report. Inspection Date: 5/1/2010. Single Family Sample Report. Property Address: Address. City State Zip. All In One Home Inspection LLC

Inspection Report. Inspection Date: 5/1/2010. Single Family Sample Report. Property Address: Address. City State Zip. All In One Home Inspection LLC Page 1 of 53 Inspection Report Inspection Date: 5/1/2010 Single Family Sample Report Property : City State Zip All In One Home Inspection LLC Joseph W Fleming III - Home Inspector License 24GI00045600

More information

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 5427 S 236th St, 10-5, Kent, WA 98032 Thank you for your interest in this Faira Certified

More information

Steve Ramsey Home Inspections

Steve Ramsey Home Inspections Steve Ramsey Home Inspections I. STRUCTURAL SYSTEMS X A. Foundations Type of Foundation(s): Slab Foundation There is evidence of some foundation movement. Excessive caulk around windows, mortar and brick

More information

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA 27966 Thackeray Avenue/ Mail address Hayward, Calif. 94544 2011 150TH AVENUE SAN LEANDRO, CALIFORNIA 21:12 August 07, 2015 Page 1 of 11 Table of Contents Definitions 2 General Information 2 Lots and Grounds

More information

Excellent Home Inspection Services, LLC

Excellent Home Inspection Services, LLC Property Inspection Report Cover Page 46143 Inspection prepared for: John and Jane Doe Date of Inspection: 4/15/2015 Age of Home: About 12 years Size: 1,600 sq ft Weather: About 60 degrees F The house

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Mr. Mrs. Property Address: 123 Main Street Any Town GA 30000 Champ Home Inspections Inc. Jim Champ 770-516-8882 Office 770-367-4123 Cell 678-494-0171 Fax www.champhomeinspections.com

More information

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ Inspection Report Eagle Eye Home Inspectors John R. Dixon 24GI00094900 625 McKinley Court Princeton, NJ 08540 732.397.3527 Table of Contents Cover Page... 1 Table of Contents... 2 Intro Page... 3 1 Roofing...

More information

Bayshore House Inspections LLC

Bayshore House Inspections LLC Cover Page Bayshore House Inspections LLC Property Inspection Report 32963 Inspection prepared for: Ron Rosenthal Date of Inspection: 3/23/2017 Time: 10:30am Age of Home: 1950 Size: 3284 Weather: Clear

More information

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM SUMMARY 1234 Main St.Severn 21144 Buyer Name 07/18/2018 9:00AM Henry Toman MD License 32391 1st American Home Inspection, LLC 443-685-4062 henrytoman61@gmail.com The summary is meant to organize the defects

More information

MAISON INSPECTIONS

MAISON INSPECTIONS MAISON INSPECTIONS 6627711103 darryl@maisoninspections.com http://www.maisoninspections.com RESIDENTIAL REPORT 1234 Main St. Leland Mississippi 38756 Buyer Name 08/05/2018 9:00AM Inspector Darryl Miles

More information

Attention To Detail Home Inspections, LLC Marchester Dr. Wesley Chapel, FL Report prepared by: Steven Milek Certified NACHI Inspector

Attention To Detail Home Inspections, LLC Marchester Dr. Wesley Chapel, FL Report prepared by: Steven Milek Certified NACHI Inspector 31530 Marchester Dr. Wesley Chapel, FL 33543 Report prepared by: Steven Milek Certified NACHI Inspector Mobile Home Report Any Street USA Any City USA Report Prepared For: Anyone January 00/00/0000 Page

More information

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 15433 Country Club Dr, B-203, Mill Creek, WA 98012 Thank you for your interest in this Faira

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Your New Address, Your Town, USA Inspection Date: Inspection Date Prepared For: New Homeowner Prepared By: Complete Home Inspectors P.O. Box 1104 Smiths Station, Alabama 36877 Phone:

More information

Hearth and Homes Inspections, llc

Hearth and Homes Inspections, llc Cover Page Property Inspection Report 44092 Inspection prepared for: Ember Griffith Real Estate Agent: Samantha Elly - Keller Williams Date of Inspection: 3/4/2017 Time: 10:00 AM Age of Home: 63 Years

More information

MHI Services Inc. Property Inspection Report

MHI Services Inc. Property Inspection Report Cover Page MHI Services Inc. Property Inspection Report 333 Some place Ave, Some Place OR, 970245 Inspection prepared for: SAMPLE REPORT & SAMPLE REPORT Inspection Date: 3/29/2009 Time: 8AM Age: 9 YEARS

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 3333 Main Street Mount Dora, FL 32757 Prepared for: Dave Penny Prepared by: PO Box 856 Mt. Dora, FL 32757 Tel 352 552 2136 davepenny@comcast.net Page 1 of 15 General Information

More information

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98296 May 10 th, 2017 We have coordinated

More information

SCOPE OF INSPECTION THE FOLLOWING SYSTEMS AND COMPONENTS, IF APPLICABLE, ARE INSPECTED DURING OUR STANDARD HOME INSPECTION.

SCOPE OF INSPECTION THE FOLLOWING SYSTEMS AND COMPONENTS, IF APPLICABLE, ARE INSPECTED DURING OUR STANDARD HOME INSPECTION. SCOPE OF INSPECTION THE FOLLOWING SYSTEMS AND COMPONENTS, IF APPLICABLE, ARE INSPECTED DURING OUR STANDARD HOME INSPECTION. Important Note: IF THE SYSTEMS AND COMPONENTS LISTED BELOW ARE NOT SPECIFICALLY

More information

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc. John Sample Property Address: 123 Main St. Alpharetta GA 30022 Inspector: Jason David Residential Inspector of America, Inc. 3276 Buford Drive, Ste. 104-306 Buford, GA 30519 770.476.4963 ICC Certified

More information

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC Inspection Report Cheri Property Address: 103 Dogleg Dr Moultrie GA Welcome Home! Shea Wynn 1709A Gornto Rd, UPS #131 Valdosta, GA 31601 229-292-4694 Table of Contents Cover Page...1 Table of Contents...2

More information

Home Inspection Standards of Practice

Home Inspection Standards of Practice Home Inspection Standards of Practice Table of Contents 1. Definitions and Scope 2. Limitations, Exceptions & Exclusions 3. Standards of Practice 3.1. Roof 3.2. Exterior 3.3. Basement, Foundation, Crawlspace

More information

Patriot Home Inspections

Patriot Home Inspections Patriot Home Inspections 898 Whispering Pines Rd Johnsonville, SC 29555 (843) 386-9100 patriothomeinspections.com info@patriothomeinspections.com Inspected By: Hubert Miles Jr, RBI 2556 Condo Inspection

More information

RW West Consultants. Property Inspection Report

RW West Consultants. Property Inspection Report Cover Page RW West Consultants Property Inspection Report 98122 Inspection prepared for: Faira Date of Inspection: 4/27/2017 Time: 9:00 AM Age of Home: 1992 Size: 3000 Weather: Cloudy 45 degrees Order

More information

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM Property Address: Age of Quarters: Years Date of Inspection: INSPECTION TEAM: Names: Profession/Position (i.e. Board Member,

More information

Home Inspection Report

Home Inspection Report Pfeifer Home Inpsection, LLC 8332 Crystal Pointe Lane Indianapolis, Indiana 46236 317-340-1734 Lic #HI01700103 Home Inspection Report Columbus, IN 47201 Page 1 of 20 Table of Contents Definitions 2 General

More information

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ Inspection Report : Eagle Eye Home Inspectors John R. Dixon 24GI00094900 625 McKinley Court Princeton, NJ 08540 732.397.3527 Table of Contents Cover Page... 1 Table of Contents... 2 Intro Page... 3 1 Roofing...

More information

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: - Cover Page RW West Consultants Property Inspection Report 98028 Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: - Date of Inspection: 5/26/2017 Time: 9:00 AM Age of Home: 2012 Size: 2480

More information

Inspection Report. Mr. John Smith. Property Address: Main St Victorville CA Schultz Property Inspections. Wayne Schultz - (760)

Inspection Report. Mr. John Smith. Property Address: Main St Victorville CA Schultz Property Inspections. Wayne Schultz - (760) Inspection Report Mr. John Property Address: 12345 Main St Victorville CA. 92392 Schultz Property Inspections Wayne Schultz - (760) 596-7479 wayne@schultzprpertyinspections.com Table of Contents Cover

More information

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM Banti Shaw InspecUs InspecUs 7808623549 bantishaw@inspecus.ca This Summary outlines potentially significant issues from a cost, safety

More information

SPS Home Inspections, LLC

SPS Home Inspections, LLC Cover Page SPS Home Inspections, LLC Property Inspection Report 00000 Inspection prepared for: Mr. & Mrs. Homeowner Real Estate Agent: - Date of Inspection: 5/1/2012 Time: 11:00 am Age of Home: 39 Size:

More information

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 11550 Stone Ave N, #205, Seattle, WA 98133 Thank you for your interest in this Faira Certified

More information

Maintence/Renewal Report

Maintence/Renewal Report Maintence/Renewal Report Property Address: C4U Inspections Lloyd Kenzle CPBC # 47652 3518 Webber Rd. West Kelowna, BC V4T 1H9 866 765-4434 Table of Contents Cover Page... 1 Table of Contents...2 I SUMMARY...

More information

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 6137 Hazel Loop SE, #D, Auburn, WA 98092 Thank you for your interest in this Faira Certified

More information

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 5650 24 th Ave NW, #407, Seattle, WA 98107 February 28 th, 2018 Thank you for your interest

More information

National Property Inspections

National Property Inspections Sunday, February 7, 2016 Inspector Eldon Holliday 901-497-0943 npi@centurytel.net Page 1 of 9 GENERAL INFORMATION GENERAL CONDITIONS AT TIME OF INSPECTION : Yes Property Occupied : Property Faces : þ North

More information

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98275 Thank you for your interest in this Faira Certified home. We have coordinated the efforts

More information

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651) Page 1 Doc #: Inspector: Date: Dwelling Address: Client Name: Client's Agent: Real Estate Company: Please refer to the General Home Inspection Contract. Thank you for using Minnesota and Western Wisconsin's

More information

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 12834 SE 41st Ln, E203, Bellevue,

More information

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98053 April 4 th 2017 We have coordinated

More information

All In One Home Inspections

All In One Home Inspections Cover Page All In One Home Inspections Property Inspection Report 34241 Inspection prepared for: Jane Smith Date of Inspection: 6/15/2015 Time: 10:00AM Age of Home: 29 Yrs Size: 1631 Lving Weather: Sunny

More information

This Report Was Prepared For: Property Address Inspected:

This Report Was Prepared For: Property Address Inspected: This Report Was Prepared For: Jane Do (to protect the identity and privacy of our clients) Property Address Inspected: 321 Sample Dr Example Report, FL 32828 Date: August 11, 2115 File # H50855255 The

More information

Chattanooga Home Inspector LLC

Chattanooga Home Inspector LLC Cover Page Chattanooga Home Inspector LLC Property Inspection Report 37377 Inspection prepared for: Happy Home Buyer & Sally Sales-a-lot Date of Inspection: 1/1/2015 Time: 2:00 PM Weather: 74 degrees and

More information

CMHC HOME MAINTENANCE CHECKLIST

CMHC HOME MAINTENANCE CHECKLIST Make sure air vents indoors and outdoors (intake, exhaust and forced air) are not blocked by snow or debris. Check and clean range hood filters on a monthly basis. Test ground fault circuit interrupter(s)

More information

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 5801 200th St SW, 301, Lynnwood,

More information

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98258 June 14 th, 2017 We have

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 7325 Dogwood Ave California City, CA 93505 Prepared for: Sherri Liu Prepared by: 6317 Sandstone Ct Lancaster, Ca 93536 Dj Durment, 661-902-9477 Page 1 of 19 Table of Contents Definitions

More information

FAIRA TRANSPARENCY REPORTS E Lake Sammamish Pwy SE, 2-103, Sammamish, WA September 21, 2016

FAIRA TRANSPARENCY REPORTS E Lake Sammamish Pwy SE, 2-103, Sammamish, WA September 21, 2016 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 3500 E Lake Sammamish Pwy SE, 2-103, Sammamish, WA 98075 September 21, 2016 Thank you for

More information

Inspection Report. Mr. John Sample. Property Address: 123 Pine Street Vancouver BC V3M6C5. Exterior Front of Home. Fairbairn Inspection Services

Inspection Report. Mr. John Sample. Property Address: 123 Pine Street Vancouver BC V3M6C5. Exterior Front of Home. Fairbairn Inspection Services Inspection Report Mr. John Property Address: 123 Pine Street Vancouver BC V3M6C5 Exterior Front of Home Fairbairn Inspection Services David Fairbairn BC License 60397 #211 810 Quayside Drive New Westminster,

More information

The Ultimate Home Maintenance Schedule

The Ultimate Home Maintenance Schedule The Ultimate Home Maintenance Schedule On-Going Quarterly Maintenance Schedule Check interior and exterior faucets for leaks. Clean aerators. Replace washers if Clean with baking soda. Pour water down

More information

FAIRA TRANSPARENCY REPORTS. October 24,2016

FAIRA TRANSPARENCY REPORTS. October 24,2016 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 2702 SW 351 st St., Federal Way,

More information

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex 1346 Hurford Ave Courtenay, BC 123 Sample 6 Plex Page 1 of 62 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 4 Structure 5 Roof 6 Electrical 9 Plumbing 11 Air Conditioning

More information

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98037 August 21, 2017 We have coordinated

More information

OBSIDIAN HOME INSPECTION (208)

OBSIDIAN HOME INSPECTION (208) OBSIDIAN HOME INSPECTION (208) 308-1049 inspections@obsidianhome.com https://www.obsidianhome.com RESIDENTIAL REPORT 1234 Main St. Kimberly Idaho 83341 Buyer Name 05/11/2018 9:00AM Inspector Tucker Petterson

More information

Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant

Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant (425) 652-6515 Kevin@Hergert.com Wa. Home Inspector 619 WSDA Inspector 79988 WSDA Control # 1336AQ-012 Client: Address: Property Description: (1) level condominium in a multi-story building Property age/

More information

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 18930 Bothell Everett Hwy, D304, Bothell, WA 98012 Thank you for your interest in this Faira

More information

Inspection Report. Rob Renfro. Property Address: 1234 Main St. Auburn WA Coastline Home Inspections

Inspection Report. Rob Renfro. Property Address: 1234 Main St. Auburn WA Coastline Home Inspections Page 1 of 48 Inspection Report Rob Property Address: Auburn WA 98002 Coastline Home Inspections Rob 11014 19th Ave. SE PMB #74 Everett, WA 98208 425-357-0956 Page 2 of 48 Table of Contents Cover Page Table

More information

fieldwork report contains the Functional

fieldwork report contains the Functional December 6, 2010 Dear Bill and Ann, On October 2, 2010, Cities Inspection Service, Inc. completed a home inspection of the property located at 2344 Arbour Lane, St. Paul, Minnesota for you. Doug Hastings

More information

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98042 Thank you for your interest in this Faira Certified home. October 10, 2017 We have

More information

Inspection Report. John R. Rohan. Property Address: 560 Pleasant View Ave. Red Wing MN 55066

Inspection Report. John R. Rohan. Property Address: 560 Pleasant View Ave. Red Wing MN 55066 Inspection Report John R. Rohan Property Address: 560 Pleasant View Ave. Red Wing MN 55066 Leise Property Services LLC Joe Leise WI 2600-106 2770 Southview Ridge Red Wing, MN 55066 651-442-3201 Table of

More information

CHARLESTON ROOTS MANAGEMENT

CHARLESTON ROOTS MANAGEMENT CHARLESTON ROOTS MANAGEMENT 8433275307 mcbeetim.crm@gmail.com http://www.loveandrenovate.org/services/ RESIDENTIAL REPORT 1234 Main St. Charleston SC 29414 Buyer Name 12/26/2017 9:00AM Inspector Tim McBee

More information

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection. BISHOP HOME INSPECTIONS, LLC. Phone (269) 686-6485 / Fax (269) 686-7798 email: bishophomeinspection@charter.net / Website: bishophomeinspection.com Inspection address: 123 rth Street Client name: Gerald

More information

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F PREPARED FOR: l (Name of Client) CONCERNING: (Address of Property) BY: (Name of Technician) (Consultation Date) YOUR HOME CHECK 1305 FM 359, Suite G Richmond, TX 77469 P 281-342-Home F 281-342-4669 I.

More information

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR Thank you for your interest in this Faira Certified home. FAIRA TRANSPARENCY REPORTS 98058 June 13 th, 2017 We have

More information

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98122 Thank you for your interest in this Faira Certified home. April 28 th, 2017 We have

More information

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com 1 (800) 571 FAIR FAIRA TRANSPARENCY REPORTS, Bellevue, WA 98006 May 11, 2016 Thank you for your interest in this Faira Certified home.

More information

Residential * Commercial * Mobile Homes * New Construction

Residential * Commercial * Mobile Homes * New Construction January 9, 2016 Mr. & Mrs. Smith RE: Lutz, FL 33549 Dear Mr. & Mrs. Smith: At your request, and in your presence or in your realtors presence, a visual inspection of the above referenced property was conducted

More information

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98037 Thank you for your interest in this Faira Certified home. We have coordinated the efforts

More information

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98198 Thank you for your interest in this Faira Certified home. We have coordinated the efforts

More information

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006 608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 98006 Thank you for your interest in this Faira Certified home. We have coordinated the efforts

More information