Environmental Chambers

Size: px
Start display at page:

Download "Environmental Chambers"

Transcription

1 Temperature & Chambers. Temperature & Chambers - Tabletop type. Fingerprint Development Chamber - Tabletop type. Temperature Chambers. Temperature Chambers - Tabletop type. Clean Temperature & Chambers. Plant Growth Chambers. Selection Guide Temperature (& ) Chambers Description Operating Temp. Range 1) ( / ) Operating Humid. Full Range 2) (%RH) Chamber Volume (L / cu ft) Page Temperature & Chamber (Floor type) Temperature & Chamber (Tabletop type) Temperature Chamber (Floor type) Temperature Chamber (Tabletop type) Clean Temperature & Chamber (Floor type) TH-G Series 25 to to 1000 / 6.4 to to 150 / -31 to 302 TH-I Series 20 to to 408 / 6.4 to 14.4 TH-GU to 150 / -76 to to / TH-TG Series -5 to to to 960 / 6.7 to 33.9 TH-ICH 3) Series -5 to to , 760 / 10.6, 26.8 TH-ME Series -20 to 150 / -4 to to to 100 /0.9 to 3.53 TH-PE Series 0 to 100 / 32 to to TH-PF-100 4) 40 to 100 / 104 to to / TC-G Series -35 to 150 / -31 to to 1000 / 6.4 to TC-GU to 150 / -76 to / TC-ME Series -20 to 120 / -4 to to 100 / 0.9 to TH-CR to 100 / -31 to to / ) Operating Temperature Rang is without. 2) Please, refer to detail specification in catalog. 3) TH-ICH Series Temperature Rang is without Light and. 4) Fingerprint development chamber. Plant Growth Chambers Description Operating Temp. Range 1) ( / ) Operating Humid. Full Range (%RH) Chamber Volume (L / cu ft) Page Plant Growth Chambers (Floor type) GC-300TL 5 to 50 / 41 to 122 GC-300TLH - Lamp off 10 to 50 / 50 to 122 GC-1000TL - Lamp on / to / / Accessories & Options Description Page for Temperature & Chambers for Plant Growth Chambers 127

2 General Applications Temperature (& ) Chambers Test for reliability, durability, climatic, freezing resistance, quality assurance, thermal endurance etc. - Testing for electric and electronic component, sensors. - Testing for semiconductor, PCB, LCD & LED. - Pharmaceutical tests. - Mechanical / Military / Aircraft engineering. - Automobile, Transport / automobile supply industries. - Chemical / Petrochemical industries. - Construction materials / Plastic / Textile industries. - Testing mould, liquor, cigar, paintings. - Testing metal related industries like plating etc. - Ninhydrin, DFO and other fingerprint development processes. (Only TH-PF-100) Plant Growth Chamber - Agriculture experiment with growth of plants. - Growth experiment of animals and insects. - Food preservation experiments. - Genetic of life science researches. - Genetic researches and pathology of plants. - Retardation researches of seeds. - Tissue culture of plants and germinating researches of seeds. Technical Benefits Safety functions 1) Self-protecting cut-off function: - over temperature, leakage electric or overvoltage automated cut the power supply for operating, heating element and controller orderly before the unit shuts down. 2) Time setting function for automated run / off: - Enable to be started or shut down automatically at a preset time. - A timer operation can be set for month, data, day of the week and time. 3) Low fluid level protection, water leakage alarm: - Intermittent tone rings and optical signal alarm. - Water supply circuit compartment is completely separate from the others for safe operation. 4) Door-open warning alarm: - Intermittent tone rings and optical signal alarm displays. - Heating element, fan and platform automatically stop when door opening to minimize heat loss and protect operator. Optimum control performance 1) Microprocess PID control / Auto-tuning / Calibration. 2) Optimize CPU logic control system. - Optimum control for temperature / humidity with economical control in power consumption. 3) Touch screen type monitor inch Color LCD with interactive input system using touch keys. (Floor Type) - Temperature & humidity / timer settings and operating condition. - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form. - Easily recognizable set values; set point (SP) / proportional value (PV) are also added on the color LED controller. Protect the global environment - HFC refrigerant causes no damage to ozone layer. - Complies with the measures for ozone layer protection specified by the Montreal Protocol.

3 Temperature (& ) Chambers 94 ON-G series is used for all sterilization and drying tasks that do not require high drying Certification only for the TH-G rates or special time requirements, ideal for drying applications requiring a gentle airflow. Floor type TH-G / TH-I / TC-G series

4 Temperature (& ) Chambers Dimensions (TH-G/ TH-I/ TC-G series) 95 Models Capacity W D H A B TH-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm (48.4 ) TH-I 300L (10.6cu ft) 1120mm (44.1 ) 1070mm (42.1 ) 1730mm (68.1 ) 450mm (17.7 ) 1230mm (48.4 ) TC-G 408L (14.4cu ft) 1120mm (44.1 ) 1240mm (48.8 ) 1730mm (68.1 ) 520mm (20.5 ) 1230mm (48.4 ) TH-G TC-G 800L (28.3cu ft) 15700mm (61.8 ) 1245mm (48.8 ) 2060mm (81.1 ) 490mm (19.3 ) 1260mm (49.6 ) 1000L (35.3cu ft) 15700mm (61.8 ) 1445mm (56.9 ) 2060mm (81.1 ) 560mm (22.0 ) 1260mm (49.6 ) Temperature & control range (TH series only) Relative % RH 98%RH 95%RH TH-G type (180, 300, 408L) TH-GU ~ 85% RH at ~ 98% RH at 25 ~ ~ 80% RH at 90 TH-G type (800, 1000L) 50 ~ 90% RH at ~ 95% RH at ~ 95% RH at 30 ~ 90 Temperature TH-I type (180, 300, 408L) 30 ~ 80% RH at ~ 98% RH at 25 ~ ~ 80% RH at 90

5 Temperature (& ) Chambers Operating & Constructional features 96 Door Catch & Trim Color LCD Controller User-friendly design Standard environmental test chambers. High quality 304 stainless steel exterior and interior. Casters for easy transport and installation. Convenient maintenance - available to check total operating time. Enough chamber capacity up to maximum 1000L. Select your optimum chamber from a full variation. - The series provide three variations in temperature (& humidity) range of -35 to 150, -35 to 120, -60 to 150 / upmost 20 to 98% RH, and five capacities of 180L, 300L, 408L, 800L, and 1000L, with a total 15 models altogether. Exclusive door lock & trim. - Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. - Door open warning alarm. Inner door. - Optional inner glass door has four holes to handle inside specimen without opening the door. (Except for 800L and 1000L) Ventilation. - Ventilation vent is located at the upper right side of the unit. Recorder. (optional) - 6-point dots type recorder with digital display. Cartridge type tank for easy water supply. - Maintenance can be done easily from the front side. - A center window allow to check the amount of water remaining easily. Viewing window for observation. - A tempered window provides a clear view of your specimen during testing. - Improved lighting provided. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port. (Optional) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning. Digital Recorder (optional) Safety functions Leakage breaker for power supply. Over current protector. Overheat / overcool protectors. Switch-off after alarm for over heating. Water empty. (TH-G / TH-GU / TH-I only) Door opening alarm. Vice lock door closing equipment.

6 Temperature (& ) Chambers Control operation Microprocess PID control / Auto-tuning / Calibration. Languages support in three kinds of English, Chinese, and Korean. Optimize CPU logic control system. - Optimum control for temperature / humidity with economical control in power consumption. Touch screen type monitor inch Color LCD with interactive input system using touch keys. - Temperature & humidity / timer settings and operating condition. - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form. - Easily recognizable set values; set point (SP) / proportional value (PV) are also added on the color LED controller. Programming operation. Description TH-G, I, GU / TC-G, GU series Programmable pattern capacity 120 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments* 1200 Programmable process time per a segment 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly. Water Tank 97 Computer interface. (optional) - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values storage. By using RS-485 communication port offer maximum 9 sets of Temperature & chamber can be connected by one PC. (optional) Air filter Multi-control Display Single-control Display Program setting Display Graph Display Ventilation

7 Temperature & Chambers Specifications & Ordering Informations 98 Chamber volume (L / cu ft) 180 / / / / / 35.3 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Range ( / ) Fluctuation 1) ( / ) at 55 / 60%RH Variation 1) ( / ) at 55 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -35 to 150 / -31 to 302 without humidity *best programmable control range : -30 to 140 / -22 to / / / / / / / / / / From -35 to 120 (-31 to 248 ) 60 From -35 to 120 (-31 to 248 ) 60 From 20 to -35 (68 to -31 ) on singe point control * 40 to 85 at 15 (59 ) 50 to 90 at 20 (68 ) 25 to 98 at 25 to 80 (77 to 176 ) 45 to 95 at 25 (77 ) 25 to 80 at 90 (194 ) 40 to 95 at 30 to 90 (86 to 194 ) Mechanical single stage refrigerator system (air-cooled condenser) 3.0 Mechanical dual stage refrigerator system (air-cooled condenser) Refrigerant R-404A R-404A (1st step), R-23 (2nd step) Capacity (W) Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) bulb (W) Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Air flow Tangent blower (90W) 4 sets of sirocco fan (4 90W) Water supply Dimensions (W D H) Model TH-G-180 TH-G-300 TH-G-408 TH-G-800 TH-G-1000 Capacity 15L (0.53cu ft) - Cartridge type Direct water supplying system Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) / / ph6.2 to 7.2 / Electrical conductivity 20 /cm to below / / / / / / / / / / Net weight (kg / lbs) / / / / / Cable Port Interface Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 23.0A - Cat. No. AAH80011 AAH80021 AAH Electrical Requirements (230V) 50Hz / 1ph / 23A 50Hz / 3ph / 22.5A Cat. No. AAH80012 AAH80022 AAH80032 AAH80042 AAH80052 Electrical Requirements (380V) 50Hz / 3ph / 7.7A 50Hz / 3ph / 13.0A Cat. No. AAH80018 AAH80028 AAH80038 AAH80048 AAH ) Technical data. (according to DIN 12880, IEC 60068) Certification only for the TH-G Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load.

8 Temperature & Chambers Specifications & Ordering Informations Model TH-I-180 TH-I-300 TH-I-408 Chamber volume (L / cu ft) 180 / / / 14.4 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Cable Port Interface Range ( / ) Fluctuation 1) ( / ) at 55 / 60%RH Variation 1) ( / ) at 55 / 60% Heating - without humidity (Min.) BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -35 to 150 / -31 to 302 without humidity *best programmable control range : -30 to 140 / -22 to / / / / / / From -35 to 120 (-31 to 248 ) Cooling - without humidity (Min.) 60 From 20 to -35 (68 to -31 ) on singe point control * Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System Refrigerant 30 to 80 at 10 (50 ) 20 to 98 at 25 to 80 (77 to 176 ) 20 to 80 at 90 (194 ) Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 1500 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 bulb (W) 1500 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Door Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) / / Polyurethane foam 100mm (3.94 ) Glass wool Tangent blower (90W) 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2 / Electrical conductivity 20 / cm to below / / / / / Net weight (kg / lbs) / / / Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 23.0A Cat. No. AAH80111 AAH80121 AAH80131 Electrical Requirements (230V) 50Hz / 1ph / 23.0A Cat. No. AAH80112 AAH80122 AAH80132 Electrical Requirements (380V) 50Hz / 3ph / 7.7A Cat. No. AAH80118 AAH80128 AAH ) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

9 Temperature & Chambers Specifications & Ordering Informations 100 Model TH-GU-300 Chamber volume (L / cu ft) 300 / 10.6 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Cable Port Range ( / ) Fluctuation 1) ( / ) at 40 / 60%RH Variation 1) ( / ) at 40 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) -60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to / / From -60 to 120 (-76 to 248 ) 65 From 20 to -60 (68 to -76 ) on singe point control 40 to 85 at 15 (59 ) 25 to 98 at 25 to 80 (77 to 176 ) 25 to 80 at 90 (194 ) Fluctuation 1) ( %RH) 3 Variation 1) ( %RH) 3 System Mechanical single stage refrigerator system (air-cooled condenser) Refrigerant R-404A / R-23 Capacity (W) 3000 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) 2000 bulb (W) 1500 Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Door Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) Net weight (kg / lbs) Polyurethane foam 100mm (3.94 ) Glass wool Tangent blower (90W) 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2/ Electrical conductivity 20 / cm to below / / / / Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Electrical Requirements (230V) 60Hz / 1ph / 29.0A Cat. No. AAH80321 Electrical Requirements (230V) 50Hz / 1ph / 29.0A Cat. No. AAH80322 Electrical Requirements (380V) 60, 50Hz / 3ph / 9.7A Cat. No. AAH ) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. Upon request, other sizes of chambers are available. Please contact with us. All specifications are under ambient temperature 20 (68 ), no load.

10 Temperature Chambers Specifications & Ordering Informations Model TC-G-180 TC-G-300 TC-G-408 TC-G-800 TC-G-1000 Chamber volume (L / cu ft) 180 / / / / / 35.3 Control system Controller Temperature Time Cooling fuzzy control system Programmable, Touch screen type controller (5.7 Color monitor) Range ( / ) -35 to 150 / -31 to 302 Fluctuation 1) ( / ) at 100 Variation 1) ( / ) at 100 Heating - without humidity (Min.) Cooling - without humidity (Min.) 0.2 / / / / / / / From -35 to 120 (-31 to 248 ) 60 From 20 to -35 (68 to -31 ) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) 60 From -35 to 120 (-31 to 248 ) Mechanical dual stage refrigerator system (air-cooled condenser) System Refrigeration Refrigerant R-404A R-404A (1st step), R-23 (2nd step) Capacity (W) Cooler Plate fin cooler Heater Ni-Cr Wire Heater Drying bulb (W) Sensor Temperature Pt 100 Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Polyurethane foam 100mm (3.94 ) Door Glass wool Air flow Tangent blower (90W) 4 sets of sirocco fan (4 90W) Interior (mm / inch) / / / / / Dimensions (W D H) Exterior (mm / inch) / / / / Viewing windows (mm / inch) / / Net weight (kg / lbs) / / / / / / Cable Port Interface Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 16.2A - Cat. No. AAH81411 AAH81421 AAH Electrical Requirements (230V) 50Hz / 1ph / 16.2A 50Hz / 3ph / 22.5A Cat. No. AAH81412 AAH81422 AAH81432 AAH81442 AAH81452 Electrical Requirements (380V) 50Hz / 3ph / 5.2A 50Hz / 3ph / 11.5A Cat. No. AAH81418 AAH81428 AAH81438 AAH81448 AAH ) Technical data. (according to DIN 12880, IEC 60068) Certification only for the TC-G Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load. Go to.com Further information on Temperature Chamber products is readily available on our website.

11 Temperature Chambers Specifications & Ordering Informations 102 Model TC-GU-300 Chamber volume (L / cu ft) 300 / 10.6 Control system Controller Temperature Time Refrigeration Cooler Heater Range ( / ) Cooling fuzzy control system Programmable, Touch screen type controller (5.7 Color monitor) -60 to 150 / -76 to 302 without humidity *best programmable control range : -50 to 140 / -58 to 284 Fluctuation 1) ( / ) at / 0.54 Variation 1) ( / ) at / 0.9 Heating (Min.) Cooling (Min.) System Refrigerant 60 From -60 to 120 (-76 to 248 ) 65 From 20 to -60 (68 to -76 ) on singe point control Mechanical single stage refrigerator system (air-cooled condenser) R-404A (1st step), R-23 (2nd step) Capacity (W) 3000 Plate fin cooler Ni-Cr Wire Heater Drying bulb (W) 2000 Temperature sensor Pt 100 Air flow Dimensions (W D H) Cable Port Interior Stainless steel #304 Exterior Stainless steel #304 Insulation Door Interior (mm / inch) Exterior (mm / inch) Viewing window (mm / inch) Net weight (kg / lbs) Polyurethane foam 100mm (3.94 ) Glass wool Tangent blower (90W) / / / / Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Electrical Requirements (230V) 60Hz / 1ph / 24.3A Cat. No. AAH81521 Electrical Requirements (230V) 50Hz / 1ph / 24.3A Cat. No. AAH81522 Electrical Requirements (380V) 60, 50Hz / 3ph / 8.3A Cat. No. AAH ) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85%. All specifications are under ambient temperature 20 (68 ), no load.

12 Temperature (& ) Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. 103 TH-TG Series TH-ICH Series

13 TEMPERATURE & HUMIDITY CHAMBERS TEMPERATURE & HUMIDITY CONTROL RANGE 104 TH-ICH TH-TG TH-TG Type (190 to 960L) 40 ~ 80% RH at ~ 95% RH at ~ 95% RH at 50 ~ ~ 80% RH at 90. Dimensions (TH-TG / TH-ICH series) TH-ICH Type (300,700L) 40 ~ 80% RH at ~ 85% RH at ~ 85% RH at ~ 85% RH at 40 ~ 85 Model Capacity W D H A B TH - TG L (6.7 cu ft) 880mm (34.6 ) 945mm (37.2 ) 1465mm (57.7 ) 420mm (16.5 ) 880mm (34.6 ) TH - TG L (10.6 cu ft) 1130mm (44.5 ) 945mm (37.2 ) 1520mm (59.8 ) 420mm (16.5 ) 905mm (35.6 ) TH - TG L (14.5 cu ft) 1130mm (44.5 ) 1045mm (41.1 ) 1520mm (59.8 ) 520mm (20.5 ) 905mm (35.6 ) TH - TG L (26.8 cu ft) 1220mm (48 ) 1175mm (46.3 ) 1965mm (77.4 ) 520mm (20.5 ) 1010mm (39.8 ) TH - TG L (33.9 cu ft) 1220mm (48 ) 1415mm (55.7 ) 1965mm (77.4 ) 635mm (25 ) 1010mm (39.8 ) TH - ICH L (10.6 cu ft) 1130mm (44.5 ) 985mm (33.8 ) 1520mm (59.8 ) 460mm (18.1 ) 905mm (35.6 ) TH - ICH L (26.8 cu ft) 1220mm (48 ) 1215mm (47.8 ) 1965mm (77.4 ) 545mm (21.5 ) 1185mm (46.7 )

14 TEMPERATURE & HUMIDITY CHAMBERS The equipment for test results in compliance with the ICH Guideline. Stability Testing Q1A (R2)-ICH, TG Chamber series. Photostability Testing Q1B (Option 2)-ICH Chamber series. 105 Constructional features High quality 304 stainless steel exterior and interior. Casters for easy transport and installation. Convenient maintenance. - Available to check total operating time. Exclusive door lock & trim. Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. Cable port for running in wires. Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port. (Optional) Water tank for easy water supply. - Maintenance can be done easily from the front side. Door locker. (Optional) Cyclic defrost function makes less influence to the Temperature & control for long term operation.(under 15 set value) Powerful 2 sirocco fans maintain constant air flow rate in the chamber. Control Operation Microprocess PID control / Auto-tuning / Calibration. Digital LCD display with touch-sensitive 7 keypads. Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition. The program patterns are memorized for 10 years even though the main power switch off, thanks to a PCB builtin battery. Expansionary parameters inputting. (Conveniently display by letters) Programming operation. Computer interface. - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values memory. - RS-232C as standard offer. Recorder. (Optional) - 6-point dots type recorder with digital display. - Digital recorder. (6-Channels) Additional TH-ICH 300, 800 Features This apparatus correctly transfers and controls each light after detecting it provides accurate data in the event of validation, equipped with light detectors. (UV light sensor / VIS light sensor) Sample has to be exposed to the light in which completely near UV energy of less than 200W-hr / m2 is provided to compare directly the results from overall intensity of less than 1.20 million lux-hr, drug substances and reagents. Convenient indication - displayed total fluorescent lamps & UV lamps operating time. Safety Functions Leakage breaker for power supply. Over current protector. Overheat protector. Switch-off after alarm for over heating. Door open warning alarm. Water empty. Vice lock door closing equipment. (Optional) Alarming when complete Photostability Test. (Only TH-ICH series)

15 TEMPERATURE & HUMIDITY CHAMBERS Specifications & Ordering Informations Model TH-TG-180 TH-TG-300 TH-TG-408 TH-TG-800 TH-TG-1000 Chamber volume (L / cu ft) 190 / / / / / 33.9 Controller PID control (LCD Type) 106 Temperature 1) Time Refrigeration Cooler Heater Sensor Air flow Range Without humidity ( / ) With humidity ( / ) Fluctuation 1) ( / ) at 40 / 60%RH Variation 1) ( / ) at 40 / 60%RH Range (%RH) Fluctuation 2) ( %RH) at 60%RH / 40 Variation 2) ( %RH) at 60%RH / 40 Heating 4) Cooling 4) 50min (-5 > 100 ) 120min (100 > -5 ) -5 ~ 100 / 23 ~ ~ 90 / 50 ~ / / / min (-5 > 100 ) 120min (100 > -5 ) FULL RANGE : 10 ~ 95%RH 40 ~ 80 at 10 / ~ 95 at 20 / ~ 95 at 40 ~ 80 / 104 ~ ~ 80 at 90 / min (-5 > 100 ) 120min (100 > -5 ) Air-cooled R-404A 55min (-5 > 100 ) 145min (100 > -5 ) System Refrigerant Capacity (W) Copper plate fin cooler Ni-Cr Wire Heater / SUS Tube Heater Drying bulb (W) bulb (W) Temperature Pt 100 Electronic sensor (Free of drying a wet pack and good response time) Internal External 2 set of sirocco fan (2 60 W) : Vertical type SUS #304 (2B polish) SUS #304 (Hairline finish) & Steel, 2.0t, Double painted & baked Insulation Polyurethane (70mm / 2.76 ) Door Operating temperature Water tank Interface Cable port Glasswool 18 ~ 30 / 64.4 ~56, 85%RH (Non-corrosive and pure place) Capacity (L / cu ft) 15 / 0.53 Water quality Viewing Window (mm / inch) Dimension (W D H) Internal (mm / inch) External (mm / inch) / / ph6.2 ~ 7.2, Electrical conductivity 20 / cm to below Basically RS-232C, [RS-485 : Optional] Basically one hole provided / 50mm (2.0 ), Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) / / / (Option) / / / / min (-5 > 100 ) 145min (100 > -5 ) / / Net weight (kg / lbs) / / / / / AC230V, 1ph, 60Hz 13.1 A 15.4 A 15.4 A 24.5 A 24.5 A Max. Power Cat.No. AAHC2001K AAHC2011K AAHC2021K AAHC231K AAHC2041K consumption AC230V, 1ph, 50Hz 12.4 A 14.7 A 14.7 A 23.5 A 23.5 A Cat.No. AAHC2002K AAHC2012K AAHC2022K AAHC2032K AAHC2042K 1) All specifications are under ambient temperature 20 (68 ), no load. 2) Technical data. (according to DIN 12880, IEC 60068) 3) The value is measured on the center of chamber at the point of vertical direction. 4) Up to 98% of the set value. Go to.com Further information on Temperature Chamber products is readily available on our website.

16 TEMPERATURE & HUMIDITY CHAMBERS Specifications & Ordering Informations Model TH-ICH-300 TH-ICH-800 Chamber volume (L / cu ft) 300 / / 26.8 Controller PID control (LCD Type) Without -5 ~ 85 / 23~185 without Light humidity ( / ) 0 ~ 85 / 32~185 with Light Temperature 1) Light source (ICH Q1B option 2) Range With humidity ( / ) Fluctuation 1) ( / ) at 40 / 60%RH Variation 1) ( / ) at 40 / 60%RH Range (%RH) Fluctuation 2) ( %RH) at 60%RH / ~ 85 / 59~185 with Light 0.3 / / / / 1.3 FULL RANGE : 20 ~ 85%RH 40 ~ 80 at 15 / ~ 85 at 20 / ~ 85 at 30 / ~ 85 at 40 ~ 75 / 104 ~ ~ 85 at 85 / 185 Variation 2) ( %RH) at 60%RH / Cool white 3) 6,000 lux 6,500 lux Ultraviolet-A 3) 4.5 W/ 5.0 W/ Light Uniformity Typical Time Required to Reach ICH Recommendation of 1.2 million lux-hr VIS.: 10% UVA : 15% 200Hr 3.0 VIS.: 15% UVA : 15% 184Hr Typical Time Required to Reach ICH Recommendation of 200 W-hr/m 2 50Hr 40Hr Time Refrigeration Cooler Heater Sensor Air flow Heating 4) 25min (20 > 85 ) 30min (20 > 85 ) Cooling 4) 35min (20 > -5 ) 40min (20 > -5 ) System Air-cooled Refrigerant R-404A Capacity (W) Copper plate fin cooler Ni-Cr Wire Heater / SUS Tube Heater Drying bulb (W) bulb (W) Temperature Pt 100 Electronic sensor (Free of drying a wet pack and good response time) Internal External 2 set of sirocco fan (2 60 W) : Vertical type SUS #304 (2B polish) SUS #304 (Hairline finish) & Steel, 2.0t, Double painted & baked Insulation Polyurethane (70mm / 2.76 ) Door Operating temperature Water tank Interface Cable port Dimension (W D H) EPDM Sheet 18 ~ 30 / 64.4 ~56, 85%RH (Non-corrosive and pure place) Capacity (L / cu ft) 15 / 0.53 Water quality ph6.2 ~ 7.2, Electrical conductivity 20 / cm to below Basically RS-232C, [RS-485 : Optional] Basically one hole provided / 50mm (2.0 ), Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Internal (mm / inch) / / External (mm / inch) / / Net weight (kg / lbs) / / AC220V, 1ph, 60Hz 15.4 A 24.5 A Max. Power Cat.No. AAHC1001K AAHC1011K consumption AC230V, 1ph, 50Hz 14.7 A 23.5 A Cat.No. AAHC1002K AAHC1012K 107 1) All specifications are under ambient temperature 20 (68 ), no load. 2) Technical data. (according to DIN 12880, IEC 60068) 3) The value is measured on the center of chamber at the point of vertical direction. 4) Up to 98% of the set value.

17 Temperature (& ) Chambers - Tabletop type Go to.com Further information on Temperature Chamber products is readily available on our website. 108 TH-ME / TH-PE / TC-ME Series In the year of 2010, this products design can be changed without prior notice.

18 Temperature (& ) Chambers - Tabletop type Temperature & control range (TH-ME/ TH-PE series only) Relative % RH TH-PE-025/065/100 TH-ME-025/065/100 (Including TH-PE control range) 85 Temperature 95%RH 35%RH 30%RH TH-ME type 55 ~ 95% RH at ~ 95% RH at ~ 95% RH at ~ 95% RH at 70~85 TH-PE type 60 ~ 95% RH at ~ 95% RH at ~ 95% RH at ~ 95% RH at 70~ Dimensions (TH-ME / TH-PE / TC-ME series) Models Capacity W D H A B TH-ME 25L (0.9cu ft) 520mm (20.5 ) 760mm (29.9 ) 867mm (34.1 ) 200mm (7.9 ) 467mm (18.4 ) TH-PE 65L (2.3cu ft) 570mm (22.4 ) 890mm (35.0 ) 1010mm (39.8 ) 235mm (9.3 ) 540mm (21.2 ) TC-ME 100L (3.53cu ft) 650mm (25.6 ) 1000mm (39.4 ) 1050mm (41.3 ) 263mm (10.4 ) 557mm (21.9 )

19 Temperature (& ) Chambers - Tabletop type Operating & Constructional features (TH-ME / TH-PE series only) 110 User-friendly design Small size & light weight. Compact design with high performance. Inner glass door Select your optimum chamber from a full variation. - The series provide three variations in temperature (& humidity) range of -20 to 150, 0 to 120, -20 to 120 / upmost 20 to 95% RH, and three capacities of 20L, 65L, and 100L, with a total 9 models altogether. Efficient system with durable materials. - The evaporating system for better thermal efficiency with corrosion-resistant materials. - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance. Water tank for easy water supply. - Maintenance can be done easily from the front side. Inner glass door for observation. - A tempered glass door provides a clear view of your specimen during testing. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We can also provide additional 50 or 80mm diameter cable port. (Optional) Optional stand for space-saving layout. - For use in limited space, we provided stand with casters for staking up two chambers. Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand. Controller Safety functions Leakage breaker for power supply. Over current protector. Overheat / overcool protectors. Switch-off after alarm for over heating. Door opening alarm. Water empty. (TH-ME / TH-PE only) Portable Digital Recorder (optional)

20 Temperature (& ) Chambers - Tabletop type Control operation Microprocess PID control / Auto-tuning / Calibration. Digital LCD display with touch-sensitive 7 keypads. Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition. The program patterns are memorized for 10 years even though the main power switch off, thanks to a PCB built-in battery. Expansionary parameters inputting. (conveniently display by letters) Programming operation. Description Programmable pattern capacity 30 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments* 300 Programmable process time per a segment TH-ME / PE, TC-ME series 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 300 not 3000, so you need to arrange the number of segment and patterns properly. Computer interface. (optional) - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values memory. Water Tank 111 Recorder. (optional) - 6-point dots type recorder with digital display. By using RS-485 communication port offer maximum 9 sets of Temperature & chamber can be connected by one PC. (optional) Multi-control Display Single-control Display Exclusive stand for the chamber Program setting Display Graph Display

21 Temperature & Chambers - Tabletop type Specifications & Ordering Informations Model TH-ME-025 TH-ME-065 TH-ME Chamber volume (L / cu ft) 25 / / / 3.53 Control system BDBC2 system - Balanced Dehumidifying & Bath Cooling control Controller Program controller (LCD type) Temperature Time Refrigeration Cooler Heater Sensor Air flow Water tank Dimensions (W D H) Cable port Interface Range ( / ) Fluctuation 1) ( / ) at 25 / 60%RH Variation 1) ( / ) at 25 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System Refrigerant -20 to 120 / -4 to 248 without humidity 0.2 / / / / / / From -15 to 120 (5 to 248 ) 60 From 20 to -15 (68 to 5 ) on singe point control * 55 to 95 at 15 (59 ) 40 to 95 at 30 (86 ) Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) Plate fin cooler (cooper) Ni-Cr Wire Heater / SUS sheath Heater Drying bulb (W) bulb (W) Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Insulation Door Steel, 1.0mm (0.04 ) / Double painted & baked Polyurethane foam 50mm (1.97 ) Glass wool Sirocco fan (60W) Capacity (L / cu ft) 5 / / / 0.32 Water quality ph6.2 to 7.2 / Electrical conductivity 20 /cm to below Interior (mm / inch) / / / Exterior (mm / inch) / / / Net weight (kg / lbs) 80 5 / / / Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 12.3A 60Hz / 1ph / 13.2A 60Hz / 1ph / 14.4A Cat. No. AAH82111 AAH82121 AAH82131 Electrical Requirements (230V) 50Hz / 1ph / 11.9A 50Hz / 1h / 12.7A 50Hz / 1ph / 13.8A Cat. No. AAH82112 AAH82122 AAH ) Technical data. (according to DIN 12880, IEC 60068) * 80mm cable access hole is NOT available for 25L chamber. (TH-ME-025) * Above the dimensions are NOT included size of attached accessories. Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

22 Temperature & Chambers - Tabletop type Specifications & Ordering Informations Model TH-PE-025 TH-PE-065 TH-PE-100 Chamber volume (L / cu ft) 25 / / / 3.53 Control system Controller Temperature Time Refrigeration Cooler Heater Sensor Air flow Water tank Dimensions (W D H) Cable port Interface Range ( / ) Fluctuation 1) ( / ) at 25 / 60%RH Variation 1) ( / ) at 25 / 60%RH Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) at 60%RH / 55 Variation 1) ( %RH) at 60%RH / 55 System Refrigerant BDBC2 system - Balanced Dehumidifying & Bath Cooling control Program controller (LCD type) 0 to 100 / 32 to 212 without humidity 0.2 / / / / / / From 0 to 120 (32 to 248 ) 30 From 20 to 0 (68 to 32 ) on singe point control * 60 to 95 at 15 (59 ) 45 to 95 at 30 (86 ) Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) Plate fin cooler (cooper) Ni-Cr Wire Heater/ SUS sheath Heater Drying bulb (W) bulb (W) Temperature Pt 100 Electronic sensor - Free of drying a wet pack and good reaction time Interior Stainless steel #304 Exterior Insulation Door Stainless steel, 1.0mm (0.04 ) / Double painted & baked Polyurethane foam 50mm (1.97 ) Glass wool Sirocco fan (60W) Capacity (L / cu ft) 5 / / / 0.32 Water quality ph6.2 to 7.2/ Electrical conductivity 20 /cm to below Interior (mm / inch) / / / Exterior (mm / inch) / / / Net weight (kg / lbs) 80 5 / / / Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 12.3A 60Hz / 1ph / 13.2A 60Hz / 1ph / 14.4A Cat. No. AAH82211 AAH82221 AAH82231 Electrical Requirements (230V) 50Hz / 1ph / 11.9A 50Hz / 1h / 12.7A 50Hz / 1ph / 13.8A Cat. No. AAH82212 AAH82222 AAH ) Technical data. (according to DIN 12880, IEC 60068) * 80mm cable access hole is NOT available for 25L chamber. (TH-PE-025) * Above the dimensions are NOT included size of attached accessories. Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load. Go to.com Further information on Temperature Chamber products is readily available on our website.

23 Temperature Chambers - Tabletop type Specifications & Ordering Informations Model TC-ME-025 TC-ME-065 TC-ME Chamber volume (L / cu ft) 25 / / / 3.53 Control system Controller Temperature Time Refrigeration Cooler Heater Cooling PID control system Program controller (LCD type) Range ( / ) -20 to 120 / -4 to 248 Program control ( / ) -15 to 120 / -5 to 248 Fluctuation 1) ( / ) at 100 Variation 1) ( / ) at 100 Heating (Min.) 0.4 / / / / / / From -15 to 120 (5 to 248 ) Cooling (Min.) 60 From 20 to -15 (68 to 5 ) on singe point control * System Refrigerant Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) Plate fin cooler (cooper) Ni-Cr Wire Heater Drying bulb (W) Temperature sensor Pt 100 Air flow Dimensions (W D H) Interior Stainless steel #304 Exterior Insulation Door Stainless steel, 1.0mm (0.04 ) / Double painted & baked Polyurethane foam 50mm (1.97 ) Glass wool Sirocco fan (60W) Interior (mm / inch) / / / Exterior (mm / inch) / / / Net weight (kg / lbs) 80 5 / / / Cable port Interface Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Basically RS-232C [RS-485(Maximum 9 Units Control)-Optional] Electrical Requirements (230V) 60Hz / 1ph / 8.8A 60Hz / 1ph/ 9.7A 60Hz / 1ph / 10.5A Cat. No. AAH86011 AAH86021 AAH86031 Electrical Requirements (230V) 50Hz / 1ph / 8.4A 50Hz / 1h / 9.3A 50Hz / 1ph / 10.0A Cat. No. AAH86012 AAH86022 AAH ) Technical data. (according to DIN 12880, IEC 60068) * 80mm cable access hole is NOT available for 25L chamber. (TC-ME-025) * Above the dimensions are NOT included size of attached accessories. Permissible ambient Condition : Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load.

24 Temperature & Chamber Go to.com Further information on Temperature Chamber products is readily available on our website. 115 Fingerprint Development Chamber Temperature & control range Relative % RH TH-PF-100 TH-PF ~ 90% RH at ~ 95% RH at ~ 95% RH at ~ 90% RH at 90 Temperature

25 Temperature & Chamber Fingerprint Development Chamber 116 Exceptional design for Ninhydrin, DFO and other fingerprint development processes. Highly precise control by microprocessor PID controller for rapid development. Advanced safety features for protect evidences. Clear watch with LED light strip and heated glass window. Operating & Constructional features [Fingerprint Development Chamber] Constructional Features Small size & light weight. Compact design with high performance. Efficient system with durable materials. - The evaporating system for better thermal efficiency with corrosion-resistant materials. - The heating system with minimized potential heat when heating or cooling for prompt reaction time and advanced performance. Stainless steel interior - High quality & Corrosion-resistant Water tank for easy water supply. - Maintenance can be done easily from the front side. (Optional Direct water system.) Large viewing window - A tempered glass door provides a clear view of your specimen during testing. Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We can also provide additional 50 or 80mm diameter cable port. (optional) Optional stand for space-saving layout. - For use in limited space, we provided stand with casters for staking up two chambers. Be sure to secure the stand onto floor with earthquake resistant fitting for your safety when using stand. SAFETY FUNCTIONS Key lockable door for your evidences. Leakage breaker for power supply. Over current protector. Overheat protector. Switch-off after alarm for overheating. Door open warning alarm. Water empty. Control Board Control Operation Intuitive Control Panel. - Sight Lamp, Window Clean, Water Level indicators. Microprocess PID control / Auto-tuning / Calibration. - Precise temperature & humidity control. - Faster fingerprints development. - Rapid recovery time after door openings. Digital LCD display with touch-sensitive 7 keypads. Easy operation with wide LCD screen. - Temperature & humidity / timer settings and operating condition. Digital Timer with acoustic alarm. - Start / Stop button for easy operation. - Digital display for time remaining. - Set time expiring alarm. Programming operation. The program patterns are memorized for 10 years even though the main powers switch off, thanks to a PCB built-in battery. Expansionary parameters inputting. (Conveniently display by letters.) Computer interface. - Available to save all data in Excel. - Provide software. - The program information, setting values backup / recovery, and temperature / humidity values memory. - RS-232C as standard offer. Recorder. (Optional) - 6-point dots type recorder with digital display.

26 Temperature & Chamber 117 Large viewing window with LED lights on both sides Heated glass window eliminates condensation. Specifications & Ordering Informations (Fingerprint development chamber) Chamber volume (L / cu ft) 100 / 3.53 Controller Temperature Heater Sensor Air flow Water tank Viewing Window (mm / inch) Cable port Interface Dimension (W D H) PID control (LCD Type) Range ( / ) 40 ~ 100 / 104 ~ 212 Fluctuation ( / ) at / 0.9 Variation ( / ) at / 0.9 Range [%RH] Fluctuation ( %RH) 3.0 Variation ( %RH) 3.0 Drying bulb bulb FULL RANGE : 50 ~ 90%RH 80 to 90 at to 95 at to 90 at 90 Ni-Cr Wire Heater / SUS cartridge Heater 400W 400W Temperature Pt 100 Internal External Insulation Door Electronic sensor (free of drying a wet pack and good response time) 2 set of sirocco fan (60W) SUS #304 (2B polish) SUS #304 & Steel, 1.0t, Double painted & baked Polyurethane (70mm) Glasswool capacity (L / cu ft) 9 / 0.32 quality Internal (mm / inch) ph6.2 ~ 7.2, Electrical conductivity 20 / cm to below / Basically one hole provided / 50mm (2.0") Optionally max. two holes available/ 50 or 80mm (2.0 or 3.2") Basically RS-232C [RS-485[Maximum 9 Units Control]-Optional] / External (mm / inch) / Weight (kg / ibs) Electrical Requirements AC230V, 1ph, 60Hz 4.5A Cat. No. Electrical Requirements AC230V, 1ph, 50Hz 4.3A Cat. No. Model Water Tank included Easy maintenance. Optional Direct water system. 115kg 5kg / AAH82331 AAH82332 Key lockable door for your evidences. TH-PF-100 Permissible ambient conditions : Temperature 18 to 30 C(64.4 to 86.0 F), Maximum relative humidity 85% Recommended ambient temperature : +20 C(68 F) All specifications are under ambient temperature 20 (68 ), no load.

27 Clean Temperature & Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. 118 TH-CR-270 Temperature & control range Relative % RH TH-CR % RH TH-CR ~ 80% RH at ~ 90% RH at ~ 90% RH at ~ 90% RH at Temperature

28 Clean Temperature & Chambers Dimensions (TH-CR-270) 119 Models Capacity W D H * A B TH-CR L (9.5 cu ft) 1180mm (46.5 ) 1120mm (44.1 ) 1935mm (76.1 ) 325mm (12.8 ) 1155mm (45.5 ) Operating & Constructional features User-friendly design Standard clean environmental test chambers. Silicone-free safe construction. High quality 304 stainless steel exterior and interior. Casters for easy transport and installation. Convenient maintenance - available to check total operating time. Exclusive door lock & trim. - Vice lock type door catch and foamed silicone packing ensure perfect chamber seal. - Door open warning alarm. Inner door. - Optional inner glass door has four hole to handle inside specimen without opening the door. Exhaust duct. - Exhaust duct is located at the upper right side of the unit. Recorder. (optional) - 6-point dots type recorder with digital display. Cartridge type tank for easy water supply. - Maintenance can be done easily from the front side. - A center window allow to check the amount of water remaining easily. Viewing window for observation. - A tempered window provides a clear view of your specimen during testing. - Improved lighting provided. Cable port for running in wires. - Basic hole of 50mm diameter cable port is standard equipped on left side of chambers for wiring to the specimen. We also provide additional 50 or 80mm diameter cable port. (Optional) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning. Inner chamber

29 Clean Temperature & Chambers 120 Capable for the best cleaned temperature and humidity chamber! Class 100 cleanness is achieved by employing a HEPA filter and a bottom-to-up laminar circulation system. Operating & Constructional features Control operation Microprocess PID control / Auto-tuning / Calibration. Languages support in three kinds of English, Chinese, and Korean. Optimize CPU logic control system. - Optimum control for temperature / humidity with economical control in power consumption. Touch screen type monitor inch Color LCD with interactive input system using touch keys. - Temperature & humidity / timer settings and operating condition. - Temperature, humidity, other operating parameters, and a record of previous operation are also displayed in graph form. - Easily recognizable set values; set point (SP) / proportional value (PV) are also added on the color LED controller. Control Panel Programming operation. Description TH-CR-270 Programmable pattern capacity 120 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments * 1200 Programmable process time per a segment 0 to 99 hr 59 min * Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment and patterns properly. Computer interface. (optional) - Computer interface. (optional) - Available to save all data in Excel. - Provide a software. - The program information, setting values backup / recovery, and temperature / humidity values storage. Door Catch & Trim Safety functions Leakage breaker for power supply. Over current protector. Overheat/ overcool protectors. Switch-off after alarm for over heating. Water empty. Door opening alarm. Vice lock door closing equipment. Air-filter

30 Clean Temperature & Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. Specifications & Ordering Informations 121 Model Chamber volume (L / cu ft) 270 / 9.5 Control system Controller Temperature Time Range ( / ) -35 to 100 / -31 to 212 Fluctuation 1) ( / ) at 40 / 60%RH 0.5 / 0.9 Variation 1) ( / ) at 40 / 60%RH 0.5 / 0.9 Heating - without humidity (Min.) Cooling - without humidity (Min.) Range (%RH) Fluctuation 1) ( %RH) 3 Variation 1) ( %RH) at 60%RH 3 TH-CR-270 BDBC2 system - Balanced Dehumidifying & Bath Cooling control Programmable, Touch screen type controller (5.7 Color monitor) Local controller (Fixed - command control) 60 From -35 to 120 (-31 to 248 ) 65 From 20 to -35 (68 to -31 ) 50 to 80 at 20 (68 ) 40 to 90 at 25 (77 ) 35 to 90 at 40 (104 ) 30 to 90 at 85 (185 ) Cleanliness Class 100 (ISO ) Refrigeration Cooler Heater Sensor Air flow Water supply Dimensions (W D H) Cable port System Refrigerant Mechanical single stage refrigerator system (air-cooled condenser) R-404A Capacity (W) 1500 Drying bulb (W) 2000 bulb (W) 2000 Temperature Pt 100 Plate fin cooler Ni-Cr Wire Heater / SUS sheath Heater Interior Stainless steel #304 Exterior Insulation Door *Silicon Free (optional) Capacity Water quality Interior (mm / inch) Exterior (mm / inch) Viewing windows (mm / inch) Net weight (kg / lbs) Electronic sensor - Free of drying a wet pack and good reaction time Stainless steel #304 (Base & Control panels are made of Stainless steel with powder coating) Polyurethane Glass wool EPDM for door packing, chamber sealing and tube Poly Urethane for DI water inlet & drainage Sirocco fan 15L (0.53cu ft) - Cartridge type ph6.2 to 7.2 / Electrical conductivity 20 /cm to below / / / / Basically one hole provided / 50mm (2.0 ) Optionally max. two holes available / 50 or 80mm (2.0 or 3.2 ) Electrical Requirements 230V / 60Hz / 1ph / 29.0A 230V / 50Hz / 1ph / 29.0A Cat. No. AAH83011 AAH83012 Electrical Requirements (380V) 380 / 50Hz / 3ph / 9.6A Cat. No. AAH ) Technical data. (according to DIN 12880, IEC 60068) Permissible ambient Condition: Temperature 18 to 30 (64.4 to 86 ), Maximum relative humidity 85% All specifications are under ambient temperature 20 (68 ), no load. Upon request, other sizes of chambers are available. Please contact with us.

31 Accessories & Options for TH/ TC series 122 Viewing window Inner door Recorder Warning signal light Viewing window A observation window is installed ONLY on all floor type chambers. (TH / TC series and TH-CR-270 without TH-ICh series) A tempered dual windows provided a clear view of your specimen during testing. Improved lighting provided. Inner door A inner glass door is provided inside of the chamber door so that specimens can be observed. Applicable to some of floor type chambers. (Table top - without hand entry ports.) Temperature and recorder 6-point dots type, channels type. Digital display. Water supply Water supply system to supply pure water for humidification. - Maintenance can be done easily from the front side. Cable port A through hole of 50 or 80mm dia. (2.0 or 3.2" dia.) is provided on the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional. Water purifier Water purifier with reverse osmosis membrane. Can be installed optionally. Shelf Wire and perforated type shelves (included shelf brackets) are made of durable stainless steel. Standard specification shelves and shelf brackets are added as required. Warning signal light A signal light to light up when malfunction occurs. Can be located upper plate of unit. Tabletop type chambers (TH-ME / TH-PE / TC-ME series / TH-PF-100) Cat. No. Description Models TH-ME TH-PE TH-PF TC-ME AAA8T504 Recorder (6 points) AAA8T505 Recorder (Digital, 6 channels) AAA8T540 RS-232C interface converter included a cable (5m / 16.4ft) AAA8T541 RS-485 interface converter included a cable (5m / 16.4ft) AAA8T542 Interface cable (5m / 16.4ft) AAA8T550 Warning signal lamp RTD679 Wire shelf for TH-ME-025 / TH-PE-025 / TC-ME-025 * - RTD680 Wire shelf for TH-ME-065 / TH-PE-065 / TC-ME-065 * - RTD681 Wire shelf for TH-ME-100 / TH-PE-100 / TH-PF-100 / TC-ME-100 * AAA Perforated shelf for TH-ME-025 / TH-PE-025 / TC-ME-025 * - AAA Perforated shelf for TH-ME-065 / TH-PE-065 / TC-ME-065 * - AAA Perforated shelf for TH-ME-100 / TH-PE-100 / TH-PF-100/ TC-ME-100 * AAA8T610 Cable port ( 50mm / 2.0 ) AAA8T611 Cable port ( 80mm / 3.2 ) AAA80631 Stand for TH-ME-025 / TH-PE-025 / TC-ME AAA80632 Stand for TH-ME-065 / TH-PE-065 / TC-ME AAA80633 Stand for TH-ME-100 / TH-PE-100 / TH-PF-100 / TC-ME-100 AAA80634 Two step stand for TH-ME-025 / TH-PE-025 / TC-ME AAA80635 Two step stand for TH-ME-065 / TH-PE-065 / TC-ME AAA8T621 Water purifier RTD0794 sensor - CFA1910 Temperature sensor (RTD type) 80mm cable access hole is NOT available for 25L chamber. (TH-ME/PE-25, TC-ME-25) Wire & Perforated shelves for Tabletop type chambers * Only for wire shelf. Models Description Included* Maximum Space Dimensions (W L) TH-ME-025 / TH-PE-025 / TC-ME mm (0.8 ) mm ( ) TH-ME-065 / TH-PE-065 / TC-ME mm (0.8 ) mm ( ) TH-ME-100 / TH-PE-100 / TH-PF-100 / TC-ME mm (0.8 ) mm ( )

32 Accessories & Options for TH/ TC series Floor type chambers (TH-G / TH-I / TH-TG / TH-ICH / TC-G series) Cat. No. Description Models TH-G TH-I TC-G TH-TG TH-ICH TH-CR 270 AAA8T500 Recorder (6 points) AAA8T505 Recorder (Digital, 6 channels) AAA8T541 Interface converter included a cable (5m / 16.4ft) AAA8T542 Interface cable (5m / 16.4ft) AAA80550 Warning signal lamp AAA81552 Inner glass door (only for 180L chambers) AAA81551 Inner glass door (only for 270, 300, 408L chambers) EDA8212 Wire shelf for TH-G-180 / TH-I-180 / TC-G-180 * EDA8213 Wire shelf for TH-G-300 / TH-I-300 / TC-G-300 * EDA8214 Wire shelf for TH-G-408 / TH-I-408 / TC-G-408 * EDA8215 Wire shelf for TH-G-800 / TH-I-800 / TC-G-800 * EDA8216 Wire shelf for TH-G-1000 / TH-I-1000 / TC-G-1000 * RTD1195 Wire shelf for TH-TG RTD1196 Wire shelf for TH-TG / ICH RTD1197 Wire shelf for TH-TG RTD1198 Wire shelf for TH-TG / ICH RTD1199 Wire shelf for TH-TG STT1040 Wire shelf for TH-CR-270 * AAA Perforated shelf for TH-G-180 / TH-I-180 / TC-G-180 * AAA Perforated shelf for TH-G-300 / TH-I-300 / TC-G-300 * AAA Perforated shelf for TH-G-408 / TH-I-408 / TC-G-408 * AAA Perforated shelf for TH-G-800 / TH-I-800 / TC-G-800 * AAA Perforated shelf for TH-G-1000 / TH-I-1000 / TC-G-1000 * AAA Perforated shelf for TH-TG AAA Perforated shelf for TH-TG / ICH AAA Perforated shelf for TH-TG AAA Perforated shelf for TH-TGTG / ICH AAA Perforated shelf for TH-TG AAA Perforated shelf for TH-CR-270 * AAA8T610 Cable port ( 50mm / 2.0 ) AAA8T611 Cable port ( 80mm / 3.2 ) AAA8T621 Water purifier AAA80622 Water cartridge tank RTD0794 sensor CFA1910 Temperature sensor (RTD type) RTD1190 Fluorescent Lamp(Cool White) for TH-ICH RTD1191 Fluorescent Lamp(Cool White) for TH-ICH RTD1188 UVA Lamp for TH-ICH RTD1189 UVA Lamp for TH-ICH AAA80680 THE-680 UV Sensor TH-ICH AAA80681 THE-681 Illumination Sensor for TH-ICH EDA9175 ULPA filter (optional) EDA9184 HEPA filter (1EA included) AAA80661 Door lock device AAA80620 Direct water system Wire & Perforated shelves for Floor type chambers Models Description Included* Maximum Space Dimensions (W L) TH-G-180 / TH-I-180 / TC-G mm (1.6 ) mm ( ) TH-G-300 / TH-I-300 / TC-G mm (1.6 ) mm ( ) TH-G-408 / TH-I-408 / TC-G mm (1.6 ) mm ( ) TH-G-800 / TH-I-800 / TC-G mm (1.6 ) mm ( ) TH-G-1000 / TH-I-1000 / TC-G mm (1.6 ) mm ( ) TH-TG mm (2.4 ) ( ) TH-TG / ICH mm (2.4 ) ( ) TH-TG mm (2.4 ) ( ) TH-TG / ICH mm (2.4 ) ( ) TH-TG mm (2.4 ) ( ) TH-CR mm (1.6 ) mm ( ) * Only for wire shelf. In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.

33 Plant Growth Chambers Go to.com Further information on Temperature Chamber products is readily available on our website. 124 GC-1000TLH

34 Plant Growth Chambers Enough capacity up to 1000L for all your plant growth needs! User-friendly programmable logic microprocessor, streamlined design optimizes air flow and temperature variation. 125 Operating features +5 to 50 (lamp off) / 10 to 50. (lamp on) Max. to 35,000Lux for GC Max. to 20,000Lux for GC-300 series. 40 to 80% RH for GC-300TLH. (at 20~35 ) 50 to 90% RH for GC-1000TLH. (at 20~35 ) 300 to 5,000ppm CO2 control. (optional) Microprocess PID control / Auto-tuning / Calibration. Digital timer: 1 min to 99 hr 59 min. Over-temperature limiter / Door opening alarm. 10 steps of temperature, humidity, and illumination profiles programmable and repeat up to 999 cycles. (self-testing) Constructional features High quality 304 stainless steel interior and dirtrepellent power coated exterior. User-friendly door system. - Silicone packing for keep inner chamber perfectly. - External door with magnetic sealing for dual airtight. - Smoothly open to minimize damage against test samples. Wide inner tempered glass doors provide a full view of the sample. - A tempered window provides a clear view of your specimen during testing. Powerful air circulator for exclusive air-flow. - Very efficient and spreading type air-flow system for plant growth. - One propeller for GC-1000TLH / A tangent blower and a sirocco fan for GC-300 series. High frequency electronic ballast lamps. - Reinforced Blue and Red spectrums lighting system for plant photosynthesis. - Economical efficiency with stable light and long life span. - Convenient exchange of lamps. Restraint of heat rising. - Unique construction to minimize the heat rising due to a luminous source. - Designed to be exhaust the heat through the upper holes. (only for GC-1000TLH) Easy cleaning of condenser air-filter. - To prevent deterioration of refrigerator, keep filtering dust by periodical filter cleaning. Casters for easy transport and installation. Electronic humidity sensor supports easy calibration and fast reaction. Dual type water level sensor. Adjustable water tank positions. (only for GC-300TLH) Separable shelf and rounded inner chamber corners for easy cleaning. Safety functions Leakage breaker for power supply. Over current protector. Overheat protectors. Switch-off after alarm for over heating. Door opening alarm. Water empty. (TLH models only) Efficient airflow for plant growth Temperature setting graph * 00:00 time value setting for the step 10 makes total number of step is 9 as the above graph.

35 Plant Growth Chambers 126 Model GC-300TL GC-300TLH GC-1000TLH Chamber volume (L / cu ft) 300 / / 35.3 Control system Temperature Illumination Range ( / ) Fluctuation ( / ) at 25 Variation ( / ) at 25 Microprocessor PID controller 5 to 50 / 41 to Lamp off 10 to 50 / 50 to Lamp on 20 to 50 / 68 to with humidity 0.1 / without humidity 0.8 / without humidity Range (Lux) 0 to 20,000 0 to 35,000 Control (steps) Lamp Fl lamp (32W 18EA) FL lamp (32W 16EA) Metal lamp (400W 3EA) 40~80 at 20~35 50~90 at 20~35 Range (RH %) - 70~90 at 36~50 60~90 at 36~50 Fluctuation ( RH) at 60% RH - 3 Co2(Optional) Range (ppm) 300 to 5,000 Sensor NDIR CO2 sensor Refrigerant (HP) 1/2 3/4 Temp. heater power (W) 750 2EA 1,500 x 2EA Humid. heater power (W) Dimensions (W D H) Interior (mm / inch) / / Exterior (mm / inch) / / Net weight (kg / lbs) 250 / / Electrical Requirements (230V) 60Hz / 12.5A 50Hz / 12.5A 60Hz / 16.0A 50Hz / 16.0A 60Hz / 30.0A 50Hz / 30.0A Cat. No. AAHA1011 AAHA1012 AAHA1021 AAHA1022 AAHA1031 AAHA1032 Lamps setting Available to control illumination values with the below lamp setting arrangements GC-300 lamp arrangement GC-1000 lamp arrangement Lamps setting for GC-300 No. Lux (lx) Set values on display Lamp diagram 1 1, , ,3 3 5, ,2,3 4 6, ,4,6 5 8, ,3,4,6 6 10, ,5,7 7 12, ,3,5,7 8 14, ,4,5,6,7 9 17, ,3,4,5,6, , ,2,3,4,5,6,7 Above the set values are measured at the center of chamber toward upside. Lamps setting for GC-1000 No. Lux (lx) Set values on display Lamp diagram 1 5, ,6 (or 5,7) 2 7, , ,5,6,7 4 12, with 4,6 (or 5,7) 5 15, ,3 6 18, ,4,5,6,7 7 21, ,3 with 4,6 (or 5,7) 8 24, ,2,3 9 28, ,3,4,5,6, , ,2,3 with 4,6 (or 5,7) 11 35, ,2,3,4,5,6,7

36 Accessories & Options for GC series Ideal for high temperature storage with user-friendly design 127 Wire Shelves Cat. No. Description Included Maximum Dimensions (W L) Models EDA mm ( ) GC-300TL GC-300TLH EDA mm ( ) GC-1000TLH Perforated Shelves Cat. No. Description Included Maximum Dimensions (W L) Models AAAA mm ( ) GC-300TL GC-300TLH AAAA mm ( ) GC-1000TLH Recorder Models Description Cat. No. All GC series Recorder (6 points) AAA8T500 CO2 Control System Models Description Cat. No. All GC series CO 2 control system AAAA1521 In addition to providing standard accessories, we will manufacture customized accessories to meet your specific requirements. Contact us for details.

Environmental Chambers

Environmental Chambers Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm

More information

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options Laboratory Refrigerators & Freezers General Purpose Laboratory Refrigerators. Pharmacy Refrigerators. General Purpose Laboratory Freezers. Selection Guide General Purpose Laboratory Refrigerators Pharmacy

More information

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens. OVENS Forced Convection. Economy Forced Convection. Vacuum. Selection Guide Convection Forced [Mechanical] Economy Forced [Mechanical] Natural (Gravity) Economy Natural (Gravity) Operating Temp. Range

More information

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

Compact design for personal use Ready to network with your computer.

Compact design for personal use Ready to network with your computer. Compact design for personal use Ready to network with your computer. Introducing a new lineup of our Bench-top Type (& Humidity) Chamber Series. Our latest models achieve superb performance in a compact

More information

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800 L capacity has been developed for reliability testing of increasingly large display

More information

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities. Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities. The Laboratory chambers incorporate a number of sophisticated technologies

More information

Refrigerated Incubators / Environmental Testing Chambers

Refrigerated Incubators / Environmental Testing Chambers Refrigerated Incubators / Environmental Testing Chambers MIR-154 MIR-254 MIR-553 MLR-351H SANYO s MIR and MLR series incubators have been recognized as exceptional units suitable for a wide range of applications.

More information

Faster Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber Faster Temperature (& Humidity) Chamber SML2SMU2 SMS2SMG2 CAT.No.E04129-V1209 Stress of 5/min. or more achieved with the large-capacity 1800L models. A faster temperature and humidity chamber with 1800

More information

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test Rapid-Rate Thermal Cycle Chamber TCC-150 CAT.NO.E06132-Z610 Uniform and highly-repeatable temperature change rate. TCC-150 enables specimen temperature ramp control. Advent of the Rapid-Rate Thermal Cycle

More information

Environmental Stress Chamber AR series

Environmental Stress Chamber AR series Environmental Stress Chamber AR series CAT.NO.E09141-W1207 Advanced reliability Environmental Stress Chambers for tomorrow's environmental testing needs Achieving reliability requires a system that delivers

More information

Constant climate chamber with ICH-compliant illumination

Constant climate chamber with ICH-compliant illumination KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert

More information

Digital incubating/ refrigerating benchtop shakers

Digital incubating/ refrigerating benchtop shakers I Incubators Incubated Shakers (Benchtop Models) Digital incubating/ refrigerating benchtop shakers Transparent lid offers great visibility and gas spring supports ensure hand-down handling of the samples

More information

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100 07 General Applications Forced Convection Natural Convection Vacuum Clean, Class 100 Forced Convection General aging and curing, Agricultural genetic, Digestion of proteins and starches, General heating/

More information

Bench-Top Type Temperature (& Humidity) Chamber

Bench-Top Type Temperature (& Humidity) Chamber Bench-Top Type Temperature (& Humidity) Chamber SHSU CAT.NO.E01111-M102 Compact design for personal use, to network with your computer. The Bench-top Type Temperature (& Humidity) Chamber Series features

More information

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY. Stability Storage Chambers & Environmental Stability Rooms STABILITY Stability Storage Chambers & Environmental Stability Rooms ARALAB ARALAB is a company specialized in designing, developing, manufacturing and servicing of environmental chambers and controlled

More information

Thermal Shock Chamber TSE 11

Thermal Shock Chamber TSE 11 Thermal Shock Chamber TSE 11 CAT.NO.E1133-V13 ESPEC offers a compact, but high performance thermal shock chamber ideal for the requirements of test standards of small and low-volume specimen. Equipped

More information

STABILITY ICH. ICH Stability Tests

STABILITY ICH. ICH Stability Tests STABILITY ICH ICH Stability Tests ARALAB ARALAB is a company specialized in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the

More information

FITOCLIMA 600 & 1200 PHARMA

FITOCLIMA 600 & 1200 PHARMA FITOCLIMA 600 & 1200 PHARMA REACH-IN CHAMBERS FOR TESTING ICH, GMP, WHO, FDA COMPLIANT FitoClima 600 PH (Stability) FitoClima 600 PLH-R (Photostability) FitoClima 1200 PH (Stability with optional double

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY FITOCLIMA 600 & 1200 STABILITY STABILITY STORAGE AND PHOTOSTABILITY TESTING CHAMBERS ICH, GMP, WHO, FDA COMPLIANT FitoClima 600 PH (Stability) FitoClima 600 PLH-R (Photostability) FitoClima 1200 PH (Stability

More information

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 STABILITY STABILITY AND PHOTOSTABILITY TESTING FITOCLIMA 600 & 1200 STABILITY STABILITY STORAGE AND PHOTOSTABILITY TESTING CHAMBERS ICH, GMP, WHO, FDA COMPLIANT Common applications include: Pharmaceuticals Cosmetics

More information

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6 06 Low Temperature Incubated Shakers Mini Hybridization Oven General Applications & Low Temp. Antibody testing, Clinical science, Hematological testing, Microbiological determinations, Microorganism, Organism

More information

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry Fitoclima Pharma Stability and Photostability Chambers for the pharmaceutical industry Compliance with ICH Q1A [Stability] and ICH Q1B [Photostability] Data logging in compliance with FDA 21 CFR Part 11

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6 06 General Applications Low Temperature Incubated Shakers Mini Hybridization Oven & Low Temp. Antibody testing, Clinical science, Hematological testing, Microbiological determinations, Microorganism, Organism

More information

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Utility. High performance by special glass. Supports high-temperature, high-humidity testing Ultra View Temperature (& Humidity) Chamber PWLPWU CAT.NO.E05128 Full visibility, with improved ease-of-use and greater functionality. High-performance temperature and humidity chambers with a glass viewing

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

External and internal circulation with powerful pumping capability

External and internal circulation with powerful pumping capability Heating Bath Circulators (General) Performance Temperature range from ambient +5 to 150. Microprocessor PID control. Three point temperature calibration / Automatic tuning / Automatic run. Accurate, stable,

More information

Recirculating Coolers

Recirculating Coolers 09 Recirculating Coolers (chillers) General Recirculating Coolers Low Temp. Recirculating Coolers Advanced Low Temp. Recirculating Coolers High Temp. Recirculating Coolers Compact Recirculating Cooler

More information

Plant growth chambers

Plant growth chambers Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect

More information

VWR symphony CO 2 INCUBATORS

VWR symphony CO 2 INCUBATORS VWR symphony CO 2 INCUBATORS Choice Stability Protection VWR symphony INCUBATORS THE CHOICE IS YOURS The VWR symphony series provides unsurpassed performance, reliability and selection. An enhanced and

More information

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer Platinous temperature and humidity chambers Top Quality Design With an Easy-to-use Touch-Screen Programmer Platinous chambers are innovative, built with the busy user in mind. If you have ever used an

More information

Faster Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber Faster Temperature (& Humidity) Chamber SM series CAT.No.E17129 Stress of 5 /min. achieved with the large-capacity 1800L models. The faster 1800L temperature and humidity chamber can handle the reliability

More information

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax Speedy and Compact High-Precision Thermal Tests Made Possible This thermal-plate system has been developed to enhance heat conductivity to the specimen. When the specimen is placed on the thermal plate,

More information

Constant climate chamber with humidity

Constant climate chamber with humidity KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

Heated and Refrigerated Incubators

Heated and Refrigerated Incubators Heated and Refrigerated Incubators MIR-162-PA MIR-262-PA MIR-154-PA MIR- 254-PA MIR-554-PA us.panasonic-healthcare.com powered by TM Heated and Refrigerated Incubators Panasonic MIR series incubators are

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF ICH series Environmental simulation chambers for constant climatic conditions with light As regards compliance with standards, performance and functionality, the characteristics

More information

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax Key technology for ensuring reliability Supports the current trend toward higher stress. High accuracy is increasingly demanded in the pursuit of reliability in the field of electronics. Liquid-to-liquidtype

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental 16 ALTERNATING CLIMATE RAMP PROGRAMMING PLUS/MINUS TEMPERATURES Climatic test chamber CTC with humidity control Temperature test chamber TTC Celsius standard software Model size: 256-42 C to +190 C (without

More information

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment: Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

Compact Ultra Low Temperature Chamber

Compact Ultra Low Temperature Chamber Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature

More information

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

HOT AIR OVEN.   NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. HOT AIR OVEN NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. HOT AIR OVEN LHAO-100 SERIES LABOCON HOT AIR OVEN LHAO-100 SERIES Labocon

More information

PHOTOSTABILITY CHAMBERS

PHOTOSTABILITY CHAMBERS PHOTOSTABILITY CHAMBERS 7540-11 / 7545-11 FASTEST ICH Q1B OPTION II ON THE MARKET Fast photoexposure allows you to test more samples, reducing development time and saving money. Caron gets you to the required

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF series Environmental simulation chambers for constant climatic conditions The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance

More information

Stability & Shelf Life

Stability & Shelf Life Stability & Shelf Life Test Chambers Lunaire Environmental provides the largest selection of standard size test chambers as well as temperature/humidity ranges to accommodate all required protocols. Our

More information

New Generation KBF 240 series

New Generation KBF 240 series Constant climate chambers New Generation 240 series The constant climate chamber is the expert for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the Radiant Warm Wall Compact Incubator Reduced Oxygen Incubator Automatic Water-Jacketed Incubator, stacked For more than 45 years, Lab-Line has been on the cutting edge of incubator development. Not only

More information

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model) - Smart-Lab system (SWOF, SWON models) - Digital Fuzzy Control System Implementing Superior Temperature Accuracy - New Jog-Dial for Users to operate in an easy and Converient way - er Temperature & er

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

KMF Environmental test chamber for constant climate

KMF Environmental test chamber for constant climate SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The

More information

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51 Liquid to Liquid Thermal Shock Chamber TSB21TSB51 CAT.NO.E3137-X13 Key technology for ensuring reliability Supports the current trend toward higher stress. High accuracy is increasingly demanded in the

More information

Benchtop CO 2 Incubator. the Oasis 6400 series

Benchtop CO 2 Incubator. the Oasis 6400 series Benchtop CO 2 Incubator the Oasis 6400 series USER CONVENIENCES The safest and most secure environment for your research Your cell cultures are safe and sound, regardless of frequent door openings. The

More information

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94 OPERATION MANUAL StableTemp Economy Mechanical Convection Oven Model : 52412-89,-90,-91,-92,-93,-94 This operation manual describes the important subjects on maintaining the product s functions, safety,

More information

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Climate chambers with illumination and humidity The BINDER KBWF series shines with its KBWF series (E5.2) Climate chambers with illumination Climate chambers with illumination and humidity The BINDER KBWF series shines with its homogeneous light distribution with natural illumination from

More information

Customized Industrial Products

Customized Industrial Products Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based

More information

Thermo Scientific Precision Ovens

Thermo Scientific Precision Ovens Thermo Scientific Precision Ovens Performance, quality and value for sample heating and drying > Global Leadership in Quality and Reliability For more than 50 years, Thermo Scientific products have been

More information

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES

TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES TEMPERATURE AND HUMIDITY TEST CHAMBER LTHC-A1 SERIES We manufacture superior quality, large walk-in temperature and humidity chamber that create a constant and uniform environment for large quantity of

More information

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40 Technical Description Laboratory Climate Test Chamber System Weiss Mat. No.:67592625 Type WKL 34/40 FACTS The test chambers types WTL/WKL with compact exterior dimensions were especially developed for

More information

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Thermo Scientific Heratherm Heating and Drying Ovens. efficient Thermo Scientific Heratherm efficient safe easy Thermo Scientific Heratherm your samples We are obsessed with sample integrity. Each of our new laboratory heating and drying ovens is designed with sample

More information

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212 MOV Series Electric Ovens Dry Heat Sterilizers /2F MOV-1/2 MOV-1S/2S SANYO MOV Series Electric Ovens and Dry Heat Sterilizers Accurate, High-Temperature Equipment for the New Generation of Scientific Research.

More information

FITOCLIMA 600 & 1200 BIO

FITOCLIMA 600 & 1200 BIO BIO FITOCLIMA 600 & 1200 BIO REACH-IN CHAMBERS FOR BIOLOGICAL RESEARCH FitoClima 600 FitoClima 1200 (optional double glazed door and high performance lights) Common applications include: Plant Growth Tissue

More information

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818) UCUF191S-86, UCUF241S-86 and UCUF281S-86 UPRIGHT ULTRACOLD FREEZERS Control and Alarm Features Manual defrost, adjustable control range from -50 C to -86 C. UL/CUL Listed. Factory preset at -80 C. Advanced

More information

Environmental simulation chamber for complex alternating climate profiles

Environmental simulation chamber for complex alternating climate profiles MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited

More information

STABILITY TEST CHAMBERS

STABILITY TEST CHAMBERS STABILITY TEST CHAMBERS MODEL NO. ACM08890 STABILITY TEST CHAMBERS MODEL NO. ACM08890 Weiber Stability Test Chambers/ are widely used for confirmatory studies for direct comparison of drug substance under

More information

Ovens. DAIHAN Scientific

Ovens. DAIHAN Scientific DAIHAN Scientific Ovens General Purpose, Economic-type, Forced-air P. 146, Gravity-air P. 147, General-type, Forced-air P. 150~151, Gravity-air P. 154~155, SMART-type, Forced-air P. 152~153, Gravity-air

More information

Thermal Shock Chambers TSA Series

Thermal Shock Chambers TSA Series Air to Air Thermal Shock Chambers TSA Series CAT.No.E99138-S903 Providing the highest specifications demanded in thermal shock chambers The TSA Series combines various performance specifications to serve

More information

Photo Stability Chamber

Photo Stability Chamber Photo Stability Chamber Environmentally friendly Temperature test Chambers powered by Meditech Technology for safe testing of specimens Meditech technologies India Pvt Ltd manufactures the most innovative

More information

ICH750L. Climate Chamber. Product specification

ICH750L. Climate Chamber. Product specification Product specification Climate Chamber ICH750L Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find

More information

TCR. Features: TISSUE CULTURE

TCR. Features: TISSUE CULTURE www.biochambers.com PROVIDING GROWTH TO RESEARCH. TCR SERIES ROOM TISSUE CULTURE Tissue Culture chambers and rooms are specifically designed to maximize research area and to provide uniform environmental

More information

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Type Test chamber capacity SC 2000 MHG approx. 3400 l Radiation area approx. 1.36 m 2 TECHNICAL DATA Characteristic values for

More information

DOUBLE DOOR FREEZER.

DOUBLE DOOR FREEZER. DOUBLE DOOR FREEZER www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. UPRIGHT FREEZER DOUBLE DOOR LUFD-25-100 SERIES Labocon

More information

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE FitoTerm & FitoClima temperature and humidity testing chambers offer highly precise and reproducible

More information

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER FITOCLIMA 1.000 ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER INTEGRATED CLIMATIC AND VIBRATION FitoTerm & FitoClima temperature and humidity testing chambers

More information

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS INCUBATORS DFI Series, 36 Liter, 80 Liter, 150 Liter, 240 Liter Incubators DFI-36 DFI-80 DFI-150 DFI-240 Incubator With Forced Convection

More information

Operation Manual. (Version 1.5.1)

Operation Manual. (Version 1.5.1) VWR symphony TM Gravity Convection General Incubator Operation Manual (Version 1.5.1) VWR symphony Gravity Convection General Incubator 414004-610, 414004-612, 414004-614, 414004-616 414004-611, 414004-613,

More information

Plant Growth Humidity Chamber

Plant Growth Humidity Chamber LABEC Plant Growth Chambers with Humidity Control are fitted with internal lights and are manufactured in Australia with high quality stainless steel for easy maintenance and excellent durability. Suitable

More information

Stability Chambers & Rooms

Stability Chambers & Rooms www.cszindustrial.com Stability Chambers & Rooms Stability Chambers CSZ Stability chambers & rooms provide a stable, temperature and/or humidity-conditioned environment for worry-free operation with a

More information

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature

More information

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions Thermo Scientific Forma Environmental Chambers Controlled Temperature Storage Solutions A Choice of Environmental Chambers to Meet Your Specific Needs From stability testing to cell culturing, CO 2, RH,

More information

Forced-air Drying Ovens www.zhichenginstrument.com ISO 9001:2000 ISO13485:2003 High Performance Proven Reliability Advanced Control Description ZXRD/A series forced-air drying ovens manufactured by ZHICHENG

More information

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page

Sterilizer. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Sterilizer Overview. Page Yamato Scientific America Innovating Science for Over 125 Years Sterilizer Contents Sterilizer Overview Steam Sterilization without dryer SK Series SN Series SQ Series Steam Sterilization with dryer SM

More information

ENVAIR lab CO2 Incubator

ENVAIR lab CO2 Incubator ENVAIR lab CO2 Incubator Laboratory Incubator Air-jacketed CO2 Incubator Introduction C02 Incubators are widely used in scientific research to grow and maintain cell cultures. A ENVAIR lab CO2 Incubator

More information

Ultra-Low Temperature Chest Freezers

Ultra-Low Temperature Chest Freezers Ultra-Low Temperature Chest Freezers SANYO Ultra-Low Temperature Chest Freezer lineups for ultra-low temperature storage needs to support the forefront of life science researches. MDF-94AT MDF-193 MDF-116

More information

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work NEW! Thermo Scientific Revco PLUS -86 C Freezers Protecting Your Life s Work Your life s work. What is it worth to you? Your life s work. What is it worth to you? You spend countless lab hours developing

More information

Cell Culture CO2 Incubators

Cell Culture CO2 Incubators Cell Culture CO2 Incubators MCO-19AIC(UV)/19AIC The industry s most complete cell culture solution for highly regulated applications or conventional incubation. MCO-19AIC EU only 0123 The MCO-19AIC CO2

More information

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions. Optimum uniformity. plus a wide temperature range

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions. Optimum uniformity. plus a wide temperature range Thermo Scientific Forma Environmental Chambers Controlled Temperature Storage Solutions Optimum uniformity plus a wide temperature range A Choice of Environmental Chambers to Meet Your Specific Needs From

More information

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32 Ultra Deep Freezers Biomedical Refrigeration I UF -86 C Technology for life 504170_8pages_dometic_UF.indd 1 10/09/08 11:17:32 UF - Ultra Deep Freezers up to -86 C The models UF 455 G & UF 755 G reflect

More information

ICH260C. Climate Chamber. Product specification

ICH260C. Climate Chamber. Product specification Product specification Climate Chamber ICH260C Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP GCCP. On this page, you can find

More information

Benchtop Test Chambers Temperature and Humidity

Benchtop Test Chambers Temperature and Humidity Benchtop Test Chambers Temperature and Humidity Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they

More information

TCC-34. Features: TISSUE CULTURE

TCC-34. Features: TISSUE CULTURE www.biochambers.com PROVIDING GROWTH TO RESEARCH. TCC-34 TISSUE CULTURE Tissue Culture chambers and rooms are specifically designed to maximize research area and to provide uniform environmental conditions.

More information

Advantages / Characteristics

Advantages / Characteristics Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg

More information

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H MINI BENCH TOP CHAMBER MODEL: MI-80-A-H Introduction: The Mini Bench top chambers are compact sized humidity chambers which can be placed on a work bench or on the optional stand provided. These chambers

More information

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL FitoTerm & FitoClima temperature and humidity testing chambers offer highly precise and reproducible conditions for climatic

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

Pioneer in HAST Technology HIRAYAMA MANUFACTURING CORPORATION

Pioneer in HAST Technology HIRAYAMA MANUFACTURING CORPORATION UNSATURATED & SATURATED HAST CHAMBERS Pioneer in HAST Technology Leaders by Innovation and service Excellence by Design and Reliability Condensation Free by design Guaranteed Accuracy Real Time Engineered

More information