Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES

Size: px
Start display at page:

Download "Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES"

Transcription

1 SECTION RESIDENTIAL APPLIANCES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Cooking appliances. 2. Cleaning appliances. B. Related Requirements: 1. Section "Unit Kitchens" for small, compact kitchen units that include residential appliances. 2. Section "Residential Plumbing Fixtures" for kitchen sinks, dishwasher air-gap fittings, waste (garbage) disposers, and instant hot-water dispensers. 1.3 ACTION SUBMITTALS A. Product Data: For each type of product. 1. Include installation details, material descriptions, dimensions of individual components, and finishes for each appliance. 2. Include rated capacities, operating characteristics, electrical characteristics, and furnished accessories. 1.4 INFORMATIONAL SUBMITTALS A. Qualification Data: For manufacturer. B. Product Certificates: For each type of appliance. C. Field quality-control reports. D. Sample Warranties: For manufacturers' special warranties. RESIDENTIAL APPLIANCES

2 1.5 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For each residential appliance to include in operation and maintenance manuals. 1.6 WARRANTY A. Special Warranties: Manufacturer agrees to repair or replace residential appliances or components that fail in materials or workmanship within specified warranty period[.] except as qualified below: 1. Warranty Period: Five years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Source Limitations: Obtain residential appliances from single source and each type of residential appliance from single manufacturer. 2.2 PERFORMANCE REQUIREMENTS A. Electrical Appliances: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. B. Gas-Fueled Appliances: Certified by a qualified testing agency for each type of gas-fueled appliance according to ANSI Z21 Series standards. C. Accessibility: Where residential appliances are indicated to comply with accessibility requirements, comply with applicable provisions in [the ABA standards of the Federal agency having jurisdiction] [and] [ICC A117.1] <Insert requirement>. 2.3 RANGES A. Electric Range RG : Freestanding range with one oven(s) and complying with AHAM ER Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. Amana; a division of Whirlpool Corporation. b. General Electric Company (Hotpoint). c. KitchenAid; a division of Whirlpool Corporation. d. LG Electronics. e. Sears Brands LLC (Kenmore). f. Whirlpool Corporation. 2. Width: 30 inches. 3. Electric Burner Elements: Four. RESIDENTIAL APPLIANCES

3 a. Coil Type: Manufacturer's standard. b. Controls: Digital panel controls, located on front. c. < 4. Oven Features: a. Capacity: 3.3 cu. ft.. b. Operation: Baking and convection. c. Broiler: Located in top of oven. d. Oven Door(s): Counterbalanced, removable, with observation window handle. e. Electric Power Rating: 1) Oven(s): Manufacturer's standard. 2) Broiler: Manufacturer's standard. f. Controls: Digital panel controls and timer display, located on front. 5. Anti-Tip Device: Manufacturer's standard. 6. Electric Power Supply: 240 V, 60 Hz, 1 phase, 30 A. 7. Material: Porcelain-enameled steel with cooktop. a. Color/Finish: White. 2.4 DISHWASHERS A. Dishwasher DW : Complying with AHAM DW Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. Amana; a division of Whirlpool Corporation. b. General Electric Company (Hotpoint). c. KitchenAid; a division of Whirlpool Corporation. d. LG Electronics. e. Sears Brands LLC (Kenmore). f. Whirlpool Corporation. 2. Type: Built-in undercounter. 3. Dimensions: a. Width: 24 inches. b. Depth: As indicated on Drawings. c. Height: As indicated on Drawings. 4. Capacity: a. Water Consumption for Full Load: 3.2 gal. per cycle. 5. Sound Level: Maximum 48 db. 6. Tub and Door Liner: Stainless steel with sealed detergent and automatic rinsing-aid dispensers. RESIDENTIAL APPLIANCES

4 7. Rack System: [Nylon] [PVC]-coated sliding dish racks, with removable cutlery basket. 8. Controls: Touch-pad controls with four wash cycles and hot-air and heat-off drying cycle options. 9. Features: a. Waste food disposer. b. Self-cleaning food-filter system. c. Hot-water booster heater for 160 deg F wash water with incoming water at 100 deg F. d. Lock-out feature. e. Half-load option. f. Delay-wash option. g. Digital display panel. h. Water softener. i. Soil-sensing water use control system. 10. Front Panel: Manufacturer's standard. a. Panel Color: White. 11. Appliance Color/Finish: White. 2.5 MICROWAVE OVENS A. Microwave Oven MO : 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. Amana; a division of Whirlpool Corporation. b. General Electric Company (Hotpoint). c. Sears Brands LLC (Kenmore). d. Whirlpool Corporation. 2. Mounting: Free Standing 3. Type: Conventional. 4. Dimensions: a. Width: 24 inches. b. Depth: 19-1/2 inches. c. Height: 14 inches. 5. Capacity: 2.0 cu. ft.. 6. Oven Door: Door with observation window and pull handle. 7. Exhaust Fan: Variable-speed fan, and with capacity. 8. Microwave Power Rating: 1000 W. 9. Electric Power Supply: 120 V, 60 Hz, 1 phase, 15 A. 10. Controls: Digital panel controls and timer display. 11. Other Features: Turntable. 12. Material: Manufacturer's standard. a. Color/Finish: White. RESIDENTIAL APPLIANCES

5 2.6 GENERAL FINISH REQUIREMENTS A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances, power connections, and other conditions affecting installation and performance of residential appliances. B. Examine roughing-in for piping systems to verify actual locations of piping connections before appliance installation. C. Examine walls, ceilings, and roofs for suitable conditions where will be installed. D. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work. E. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. Install appliances according to manufacturer's written instructions. B. Built-in Equipment: Securely anchor units to supporting cabinets or countertops with concealed fasteners. Verify that clearances are adequate for proper functioning and that rough openings are completely concealed. C. Freestanding Equipment: Place units in final locations after finishes have been completed in each area. Verify that clearances are adequate to properly operate equipment. D. Range Anti-Tip Device: Install at each range according to manufacturer's written instructions. 3.3 FIELD QUALITY CONTROL A. Perform the following tests and inspections: RESIDENTIAL APPLIANCES

6 1. Perform visual, mechanical, and electrical inspection and testing for each appliance according to manufacturers' written recommendations. Certify compliance with each manufacturer's appliance-performance parameters. 2. Leak Test: After installation, test for leaks. Repair leaks and retest until no leaks exist. 3. Operational Test: After installation, start units to confirm proper operation. 4. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and components. B. An appliance will be considered defective if it does not pass tests and inspections. C. Prepare test and inspection reports. 3.4 DEMONSTRATION A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain residential appliances. END OF SECTION RESIDENTIAL APPLIANCES

7 SECTION FOODSERVICE EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Self-contained refrigeration equipment. 2. Ice maker 3. Fabricated equipment. 4. Carts B. Related Requirements: 1. Section "Commercial-Kitchen Hoods" for ventilation hoods. 1.3 COORDINATION A. Coordinate foodservice equipment layout and installation with other work, including layout and installation of lighting fixtures, HVAC equipment, and fire-suppression system components. B. Coordinate locations and requirements of utility service connections. C. Coordinate sizes, locations, and requirements of the following: 1. Equipment bases. 2. Insulated floors. 3. Floor areas with positive slopes to drains. 4. Floor sinks and drains serving foodservice equipment. 1.4 ACTION SUBMITTALS A. Product Data: For each type of product. Include the following: 1. Manufacturer's model number. 2. Accessories and components that will be included for Project. 3. Clearance requirements for access and maintenance. 4. Utility service connections for water, drainage, power, and fuel; include roughing-in dimensions. B. Shop Drawings: For fabricated equipment. Include plans, elevations, sections, roughing-in dimensions, fabrication details, utility service requirements, and attachments to other work. FOODSERVICE EQUIPMENT

8 C. Samples for Initial Selection: For units with factory-applied color finishes. D. Samples for Verification: For each factory-applied color finish required, in manufacturer's standard sizes. 1.5 INFORMATIONAL SUBMITTALS A. Coordination Drawings: For foodservice facilities. 1. Indicate locations of foodservice equipment and connections to utilities. 2. Include plans and elevations; clearance requirements for equipment access and maintenance; details of equipment supports; and utility service characteristics. 3. Include details of seismic bracing for equipment. B. Sample Warranty: For special warranty. 1.6 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For foodservice equipment to include in emergency, operation, and maintenance manuals. 1. In addition to items specified in Section "Operation and Maintenance Data," include the following: a. Product Schedule: For each foodservice equipment item, include the following: 1) Designation indicated on Drawings. 2) Manufacturer's name and model number. 3) List of factory-authorized service agencies including addresses and telephone numbers. 1.7 FIELD CONDITIONS A. Field Measurements: Verify actual dimensions of construction contiguous with foodservice equipment by field measurements before fabrication. Indicate measurements on Coordination Drawings. 1.8 WARRANTY A. Refrigeration Compressor Warranty: Manufacturer agrees to repair or replace compressors that fail in materials or workmanship within specified warranty period. 1. Failure includes, but is not limited to, inability to maintain set temperature. 2. Warranty Period: Five years from date of Substantial Completion. FOODSERVICE EQUIPMENT

9 PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. NSF Standards: Provide equipment that bears NSF Certification Mark or UL Classification Mark certifying compliance with applicable NSF standards. B. UL Certification: Provide electric and fuel-burning equipment and components that are evaluated by UL for fire, electric shock, and casualty hazards according to applicable safety standards, and that are UL certified for compliance and labeled for intended use. C. Steam Equipment: Provide steam-generating and direct-steam heating equipment that is fabricated and labeled to comply with 2013 ASME Boiler and Pressure Vessel Code. D. Regulatory Requirements: Install equipment to comply with the following: 1. ASHRAE 15, "Safety Code for Mechanical Refrigeration." 2. NFPA 54, "National Fuel Gas Code." 3. NFPA 70, "National Electrical Code." 4. NFPA 96, "Ventilation Control and Fire Protection of Commercial Cooking Operations." E. Seismic Restraints: Comply with SMACNA's "Kitchen Ventilation Systems and Food Service Equipment Fabrication and Installation Guidelines," Appendix A, "Seismic Restraint Details," unless otherwise indicated. 2.2 SELF-CONTAINED EQUIPMENT A. Refrigeration Equipment: Refrigerators. B Description: Reach-in type. a. Exterior Finish: Stainless steel.front Aluminum sides and back b. Interior Finish: Aluminum walls with stainless floor c. Doors: Full length. d. Accessories: 1) Casters. 2) Stainless-steel back with rear louvers. 3) Hinged doors and LED Light fixtures. 4) Wire shelves 5 total e. Electrical Service: Equip unit with plug and cord for service indicated on Drawings. f. Manufacture 1) True T-23 Basis if design 2) Kelvantor 3) Delfield FOODSERVICE EQUIPMENT

10 B. Refrigeration Equipment: Freezers. B Description: Reach-in type. a. Exterior Finish: Stainless steel.front Aluminum sides and back b. Interior Finish: Aluminum walls with stainless floor c. Doors: Full length. d. Accessories: 1) Casters. 2) Stainless-steel back with rear louvers. 3) Hinged doors and LED Light fixtures. 4) Wire shelves 5 total e. Electrical Service: Equip unit with plug and cord for service indicated on Drawings. f. Manufacture 1) True T-23F Basis if design 2) Kelvantor 3) Delfield C. Proofing Holding Cabinet B Description: Freestanding units. a. Insulated Proofing /Holding Cabinet b. 5 Wire shelves c. Digital Thermometer d. 4-5 Swivel casters e. Wraparound bumper f. Electrical Service: Equip unit for connection to service indicated on Drawings. g. Manufacture : 1) Lockwood CA71-PFIN-ID-R 2) Hatco 3) Metro 4) Cres-Cor D. Ice-Making Machine B Description: Freestanding units. a. Production: Ice cubes. b. Capacity: 288 Lb per 24-hour period. c. Storage Bin: 300 lb BD-300SF d. Stainless-steel exterior and legs. e. Water filter. One course filter one fine filter f. Electrical Service: Equip unit for connection to service indicated on Drawings. g. Manufacture 1) Hoshizaki KML 351 MAH Basis of design 2) Ice -o-matic 3) Manitowoc FOODSERVICE EQUIPMENT

11 2.3 FABRICATED EQUIPMENT A. Stainless-Steel Sinks D Description: Four-compartment sink(s). Fabricate units of welded stainless steel, sound deadened. 2. bowl and drainboard sizes a. Bowls:16 x 20 x 14 deep Stainless steel, Type 304, thick. b. Integral Drainboards:18 Stainless steel, Type 304, thick. c. Back Splash: Manufacturer's standard height. d. Side Splash: Manufacturer's standard height. e. Legs and Feet: Stainless-steel tubing legs with adjustable bullet feet. f. Accessories: 1) Faucets and 12 Spouts: One required K-1 2) Pre-rinse Faucet wit 12 spout, one required K116 &K117 with all mount bracket length to suite 3) Lever waste with over flow one at each bowl K 15 4) Contionous waste g. Fabrication: Prepare sink for installation Provide Z clip to fasten sink to wall no exposed fasteners h. Mnaufacture; 1) Advance Tabco RL 2) Sun-Fab 3) Eagle 4) Aero B. Stainless-Steel Shelf Units D Description: Wall mounted. Fabricate 12 deep stainless steel, 16 Gauge a. Two unites one each side of pre-rinse. Total length of pot was sink b. Hooks under shelf to hang pots c. Stainless-Steel Brackets d. Manufacture 1) Revise list below to suit Project. Indicate quantities and locations of accessories on Drawings. 2) Advance Tabco 3) Sun-Fab 4) Eagle 5) Aero C. Stainless-Steel Tables E Description: Flat-countertop table. 48 x 30 a. Tops: Stainless steel, thick, reinforced and sound deadened. 16 Gauge 1) Back Splash: Manufacturer's standard height. 2) Edge: Bullnose on four sides. b. Welded Undershelf: Stainless steel. 18 Gauge c. Legs: Stainless-steel tubing. d. Feet: Stainless-steel adjustable bullets. e. Manufacture 1) Advance Tabco- FMS-244 2) Sun-Fab 3) Eagle FOODSERVICE EQUIPMENT

12 4) Aero 2.4 CARTS A. Utility Cart J Description: Unity cart Bussing cart a. All welded stainless steel or Aluminum b wide long c. 5 swivel castors two fixed d. Two shelves e. Manufacture 1) ChannelUB1827S-2 2) Sun-Fab 3) Eagle 2.5 MISCELLANEOUS MATERIALS A. Installation Accessories, General: NSF certified for end-use application indicated. B. Elastomeric Joint Sealant: ASTM C 920; silicone. Type S (single component), Grade NS (nonsag), Class 25, Use NT (nontraffic) related to exposure, and Use M, G, A, or O as applicable to joint substrates indicated. 1. Public Health and Safety Requirements: a. Sealant is certified for compliance with NSF standards for end-use application indicated. b. Washed and cured sealant complies with the FDA's regulations for use in areas that come in contact with food. 2. Cylindrical Sealant Backing: ASTM C 1330, Type C, closed-cell polyethylene, in diameter greater than joint width. 2.6 FINISHES A. Stainless-Steel Finishes: 1. Surface Preparation: Remove tool and die marks and stretch lines, or blend into finish. 2. Polished Finishes: Grind and polish surfaces to produce uniform finish, free of cross scratches. a. Run grain of directional finishes with long dimension of each piece. b. When polishing is completed, passivate and rinse surfaces. Remove embedded foreign matter and leave surfaces chemically clean. B. Powder-Coat Finishes: Immediately after cleaning and pretreating, electrostatically apply manufacturer's standard, baked-polymer, thermosetting powder finish. Comply with resin manufacturer's written instructions for application, baking, and minimum dry film thickness. FOODSERVICE EQUIPMENT

13 PART 3 - EXECUTION 3.1 INSTALLATION A. Install foodservice equipment level and plumb, according to manufacturer's written instructions. 1. Connect equipment to utilities. 2. Provide cutouts in equipment, neatly formed, where required to run service lines through equipment to make final connections. B. Complete equipment assembly where field assembly is required. 1. Provide closed butt and contact joints that do not require a filler. 2. Grind field welds on stainless-steel equipment until smooth and polish to match adjacent finish. C. Install equipment with access and maintenance clearances that comply with manufacturer's written installation instructions and with requirements of authorities having jurisdiction. D. Install cabinets and similar equipment on bases in a bed of sealant. E. Install closure-trim strips and similar items requiring fasteners in a bed of sealant. F. Install joint sealant in joints between equipment and abutting surfaces with continuous joint backing unless otherwise indicated. Produce airtight, watertight, vermin-proof, sanitary joints. 3.2 CLEANING AND PROTECTING A. After completing installation of equipment, repair damaged finishes. B. Clean and adjust equipment as required to produce ready-for-use condition. C. Protect equipment from damage during remainder of the construction period. 3.3 DEMONSTRATION A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain foodservice equipment. END OF SECTION FOODSERVICE EQUIPMENT

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades SECTION 11 3100 - RESIDENTIAL APPLIANCES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Special Conditions and Division 01 Specification

More information

B. Product Schedule: For appliances. Use same designations indicated on Drawings.

B. Product Schedule: For appliances. Use same designations indicated on Drawings. SECTION 113100 - RESIDENTIAL APPLIANCES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A PN 2009044A PART 1 GENERAL 1.1 SUBMITTALS A. Product Data: For each appliance type required indicating compliance with requirements. Include complete operating and maintenance instructions for each appliance.

More information

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 40 11 CUSTOM FABRICATED FOODSERVICE EQUIPMENT SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 104413 FIRE EXTINGUISHER CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES SECTION 105200 - FIRE-PROTECTION SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers. SECTION 10 44 13 - FIRE-PROTECTION SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION FIRE EXTINGUISHER CABINETS

SECTION FIRE EXTINGUISHER CABINETS SECTION 104413 FIRE EXTINGUISHER CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Canning Shed/Facility Equipment Specifications

Canning Shed/Facility Equipment Specifications Canning Shed/Facility Equipment Specifications Item Qty Description 1 1 ea WALK IN COOLER Fast Trak Indoor One Compartment Walk In, 8' x 8' x 7' 7" H, compartments, cooler with smooth aluminum interior

More information

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017 SECTION 104413 - FIRE PROTECTION CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS SECTION 236200 - PACKAGED COMPRESSOR AND CONDENSER UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply

More information

SECTION ELECTRIC WATER HEATERS

SECTION ELECTRIC WATER HEATERS SECTION 22 36 01 ELECTRIC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 FUEL-FIRED, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 22 40 00 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Faucets for lavatories, bathtubs, bathtub/showers, showers and sinks. 2. Flushometers. 3. Toilet

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

SECTION ELECTRIC WATER HEATERS

SECTION ELECTRIC WATER HEATERS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 31 13 (August 2017) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-11 31 13 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 3300 - ELECTRIC, DOMESTIC WATER HEATERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture. SECTION 125500-WALL BED SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION SECTION 224100 - RESIDENTIAL PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION224213.13 -COMMERCIAL WATERCLOSETS PART 1- GENERAL 1.1 SUMMARY Section Includes: 1. Water closets. 2. Flushometer valves. 3. Toilet seats. 1.2 ACTION SUBMITTALS Product Data: For each type of product.

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Construction Standards Page

Construction Standards Page Construction Standards Page 236313-1 SECTION 236313 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

APPENDIX 3J FOOD SERVICES SPECIFICATIONS

APPENDIX 3J FOOD SERVICES SPECIFICATIONS APPENDIX 3J FOOD SERVICES SPECIFICATIONS 1. FOOD SERVICES 1.1 Design Consultant Project Co will retain as part of its professional design team a qualified food service consultant that is a professional

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 31 13 (August 2008) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-11 31 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017 SECTION 10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING SECTION 23 23 00 (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. 3. Joining Materials. 4. Specialties. B. Related Sections: 1. Section 07 92 00 (07920)

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018 SECTION 10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials. B B11.0 DIVISION 08 - OPENINGS SECTION 08 17 00 INTEGRATED DOOR OPENING ASSEMBLIES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and

More information

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209)

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209) FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box 11867 Fresno, CA 93775 Telephone (209) 445-3392 CONSTRUCTION REQUIREMENTS FOR RETAIL FOOD ESTABLISHMENTS BEFORE CONSTRUCTING, ENLARGING,

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

Appliance bid Recap. Sears APPLIANCE BID # APP Effective 4/18/2010 thru 4/17/ White. GTS18IC wht/bis/blk.

Appliance bid Recap. Sears APPLIANCE BID # APP Effective 4/18/2010 thru 4/17/ White. GTS18IC wht/bis/blk. 2 item #'s Description Brand Model # Color NO BID NO BID 5 days NO BID 3 1 18 CUBIC FT., REFRIRATOR. AUTOMATIC ICE MAKER Frost free, right or left door opening, textured steel doors, freezer compartment

More information

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features: PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fast-transfer central battery inverters with the following features: 1. Emergency-only circuits. 1.2 DEFINITIONS A. LCD: Liquid-crystal display. B.

More information

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

B. Shop Drawings: Include diagrams for power, signal, and control wiring. SECTION 224213.13 - COMMERCIAL WATER CLOSETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION 10 SPECIALTIES

DIVISION 10 SPECIALTIES DIVISION 10 SPECIALTIES 11/11 SECTION 10 21 13.16 PLASTIC LAMINATE TOILET COMPARTMENTS PART 1 - GENERAL 1.01 SECTION INCLUDES Plastic laminate toilet compartments, urinal screens, head rail braced. 1.02

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

A. This Section includes the following emergency plumbing fixtures:

A. This Section includes the following emergency plumbing fixtures: Page 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION FOOD COOKING EQUIPMENT

SECTION FOOD COOKING EQUIPMENT PART 1 GENERAL 1.1 DESCRIPTION SECTION 11 44 00 FOOD COOKING EQUIPMENT SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are

More information

Shop Drawings: For fire protection cabiaets, lnclode plans, elevations, sections, details, and attachments to other work.

Shop Drawings: For fire protection cabiaets, lnclode plans, elevations, sections, details, and attachments to other work. SECTION 104413 - PART 1 - GENERAL 1,1 RELATED DOCUMENTS Drawings and general provisions of the Contract, inclnding General and Snpplementary Conditions and Division 01 Specification Sections, apply to

More information

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. SECTION 23 23 00 (15530) - REFRIGERANT PIPING 3. Joining Materials. 4. Specialties. B. Related Sections: 1.02 REFERENCES 1. Section

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES SECTION 10 00 00 - SPECIALTIES 10 28 12 - TOILET PARTITIONS: Owner Preferences: Solid core phenolic, polymer based solid surfacing, and solid plastic toilet compartment and screen systems. No Stainless

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

Specifications 7/25/2012

Specifications 7/25/2012 Item 1 - MERCHANDISER, OPEN (1 REQ'D) Project Aspen Art Museum-Cafe From Jeff Katz (303) 440-4142 RPI Industries Model SCRFC3648R Bravo Air Screen Display Case, 36" L x 48" H, self-contained refrig., front

More information

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13 x 9 baking dish. Drop-In Microwave Cooktop FPEC3085K FFMV164L S S 30" Electric Over-The-Range Product Dimensions Height 16-13/32" Width 29-7/8" Depth 15-1/32" More Easy-To-Use Features Two-Speed Ventilation Over-the-range

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018 SECTION 26 2913 - ENCLOSED CONTROLLERS GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

PROJ. NO SECTION REFRIGERANT PIPING

PROJ. NO SECTION REFRIGERANT PIPING SECTION 23 23 00 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 22 63 13 GAS PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Ready-Select Controls. Select options or control cooking temperature with our easy-to-use controls. Even Baking Technology

Ready-Select Controls. Select options or control cooking temperature with our easy-to-use controls. Even Baking Technology Drop-In Freestanding Cooktop Range FPEC3085K FFEF4015L WS 30" 40" Electric Product Dimensions Height (Max.) 47-1/4" Width 40-1/8" Depth (Including Handle) 27-3/4" More Easy-To-Use Features Store-More Storage

More information

X PARK BUILDING, SITE, AND LANDSCAPING NEW STATE PARK SECTION COMMERCIAL LAUNDRY EQUIPMENT PART 1 GENERAL 1.

X PARK BUILDING, SITE, AND LANDSCAPING NEW STATE PARK SECTION COMMERCIAL LAUNDRY EQUIPMENT PART 1 GENERAL 1. SECTION 111100- COMMERCIAL LAUNDRY EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Washer extractors. B. Drying tumblers. C. Lint filters. 1.2 RELATED SECTIONS A. Section 03300- Cast-In-Place Concrete:

More information

Appliances SAVE THE SALES RECEIPT! It is your proof of purchase and required for the limited warranty to apply.

Appliances SAVE THE SALES RECEIPT! It is your proof of purchase and required for the limited warranty to apply. Inter IKEA Systems B.V. (April 23, 2014) Canada FY15 Appliances SAVE THE SALES RECEIPT! It is your proof of purchase and required for the limited warranty to apply. To make planning your kitchen even easier,

More information

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work. Buchtel/Perkins Community Learning Center GPD -2007271.15 OSFC Project # 55-7110-9029425 Phase 3 CLC Package Bidding Documents July 1, 2010 SECTION 15513 CONDENSING BOILERS PART I- GENERAL 1.1 RELATED

More information

Structural Guidelines. Food Service Establishments. Retail Food Stores

Structural Guidelines. Food Service Establishments. Retail Food Stores Structural Guidelines for Food Service Establishments and Retail Food Stores Jefferson County Department of Health Food & Lodging Protection Division 1 Before construction or remodeling of a food service

More information

SECTION COMMERCIAL-KITCHEN HOODS

SECTION COMMERCIAL-KITCHEN HOODS SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 B9.1 In Ground Page 1 of 6, Aug 12 DIVISION 08 - OPENINGS SECTION 08 71 13 POWER DOOR OPERATORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components. Page 238126-1 SECTION 238126 - This Section includes requirements for the LEED Rating System. However, equipment specified in this Section may not qualify for LEED Rating System prerequisites and credits.

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

More information

REFRIGERATOR FEATURES AND SPECIFICATIONS

REFRIGERATOR FEATURES AND SPECIFICATIONS REFRIGERATOR FEATURES AND SPECIFICATIONS ORIGINAL SIZE MODEL: (21TF) RETROPOLITAN MODEL: (19BF) 32 7/8" 29 3/4" 34 3/4" 28 1/4" 33 1/2" 32 3/4" 27 5/8" 30 7/8" 33 1/8" 30 1/8" 68 1/2" 67" 26 1/2" Total

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated. PART 1 - GENERAL 1.1 SUMMARY A. This Section includes 1. Hydronic baseboard radiators. 2. Hydronic finned-tube radiators. 3. Hydronic convectors. 1.2 SUBMITTALS A. Product Data: Include rated capacities,

More information

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13 x 9 baking dish. Drop-In Microwave Cooktop FPEC3085K FFMV164L S S 30" Electric Over-The-Range Product Dimensions Height 16-5/16" Width 29-7/8" Depth 15-1/32" More Easy-To-Use Features Two-Speed Ventilation Over-the-range

More information

CULINARY OPERATIONS September 30, 2010

CULINARY OPERATIONS September 30, 2010 CULINARY OPERATIONS September 30, 2010 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and for any requirements that may differ from the prototype

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,

More information

Pharmette Medicine Centers

Pharmette Medicine Centers CMP has been building for over 65 years. CMP s are ideal for securing and organizing narcotics. High quality stainless steel construction helps maintain a sanitary environment and will last for many years.

More information

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION July-December 2018 u ENERGY STAR Qualified All features apply to all units, except as noted. Aluminum with stainless steel floor interior and back Refrigerators

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based

More information

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - Systems and Equipment. Page 238239-1 SECTION 238239 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option Drop-In Microwave Cooktop FPEC3085K FFMV154CL S 30" Electric Over-The-Range Featuring Bake & Brown Convection Product Dimensions Height 16-13/32" Width 29-7/8" Depth 15-1/32" More Easy-To-Use Features

More information

FOOD SERVICE May 6, 2016

FOOD SERVICE May 6, 2016 FOOD SERVICE May 6, 2016 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and any requirements that may differ from the prototype requirements

More information

C. Samples for Initial Selection: For units with factory-applied color finishes.

C. Samples for Initial Selection: For units with factory-applied color finishes. SECTION 238126- SPLIT-SYSTEM AIR-CONDITIONERS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. Page 238219-1 SECTION 238219 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS

PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS COURTESY OF WHITMAN COUNTY DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION 310 NORTH MAIN STREET COLFAX, WA 99111 (509)

More information

XRRS Specification Fire Ready Hood

XRRS Specification Fire Ready Hood XRRS Specification Fire Ready Hood ************************************************************************************************************************ Note to User: This document is subject to copyright

More information

Food Service Establishment Plan Review Form

Food Service Establishment Plan Review Form CITY OF PARK RIDGE 505 BUTLER PLACE PARK RIDGE, IL 60068 TEL: 847/ 318-5291 FAX: 847/ 318-6411 TDD:847/ 318-5252 URL:http://www.parkridge.us Food Service Establishment Plan Review Form THE FOLLOWING INFORMATION

More information

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option Drop-In Microwave Cooktop FPEC3085K FFMV154CL S 30" Electric Over-The-Range Featuring Bake & Brown Convection Product Dimensions Height 16-5/16" Width 29-7/8" Depth 15-1/32" More Easy-To-Use Features Ready-Select

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

2018 Appliance Selections

2018 Appliance Selections 2018 Appliance Selections www.commodore-pa.com 1 Silver Bundle Bundles 21 Cu. Ft. Top-Freezer Refrigerator Adjustable Temperature Controls 2 Store-More Humidity - Controlled Crisper Drawers Store-More

More information

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening. DIVISION 8 OPENINGS SECTION 08 33 23 PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead coiling counter fire doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Support framing and framed opening.

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes ac,

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No SECTION 213113 - ELECTRIC-DRIVE, CENTRIFUGAL FIRE PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

If it looks as if it could be in a restaurant kitchen, well,

If it looks as if it could be in a restaurant kitchen, well, Model R366 Porcelain-coated cast iron top grates Infrared griddle (optional) 5" (127) riser (optional) Dual brass burners Model R364C Location of rating plate Burner drip pan Model R364G Oven light switch

More information

NEW ITEMS Lab Sinks Lab Workstations S/S Countertops Custom Fabrication. Solutions for. Cleanroom & Lab

NEW ITEMS Lab Sinks Lab Workstations S/S Countertops Custom Fabrication. Solutions for. Cleanroom & Lab NEW ITEMS Lab Sinks Lab Workstations S/S Countertops Custom Fabrication Solutions for Cleanroom & Lab Gowning Racks These racks are designed for efficient storage of garments in the cleanroom. Available

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 400 SPECIFICATION Smoke Guard, Inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.376.1600 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

SECTION FAN COIL UNITS

SECTION FAN COIL UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SECTION GAS-FIRED RADIANT HEATERS

SECTION GAS-FIRED RADIANT HEATERS SECTION 23 55 23 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

SECTION FIRE-RATED GLASS AND FRAME

SECTION FIRE-RATED GLASS AND FRAME Wiss, Janney, Elstner Associates, Inc. SECTION 08 81 17.1 FIRE-RATED GLASS AND FRAME PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-rated glazing and frame installed as interior window in fire-rated

More information

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services Page 238216-1 Copyright 2003 and 2005 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 44 00 (August 2017) ---------------------------- Preparing Activity: USACE Superseding UFGS-11 44 00 (January 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

New Food Service Plan Review Checklist

New Food Service Plan Review Checklist New Food Service Plan Review Checklist The following items should be completed before you return your application. Read Starting a Food Service Brochure to help you in the process. Confirm whether property

More information

Specifications 2/11/2014

Specifications 2/11/2014 2//204 Item K0A - Project CPC NY Project 54 Old Westbury Road Old Westbury NY 568 RANGE, 36", 6 OPEN BURNERS ( REQ'D) From Supreme Restaurant Equipment Matt Hancock cell 423-763-8386 797 Old Lee Highway

More information

Extra-Large Element. With our extra-large 12" element, you have more flexibility to fit larger pots and pans. One-Touch Self-Clean

Extra-Large Element. With our extra-large 12 element, you have more flexibility to fit larger pots and pans. One-Touch Self-Clean Drop-In Slide-In Ranges Cooktop FPEC3085K FFES3025P S / W / B 30" Electric Product Dimensions Height (Max.) 36-5/8" Width 30" Depth 28-5/16" More Easy-To-Use Features Signature Features Large Capacity

More information

APPLIANCES APPLIANCES

APPLIANCES APPLIANCES APPLIANCES APPLIANCES GE & Hotpoint Appliances...1438-1458 Whirlpool & Amana Appliances...1459-1470 Hospitality Refrigerators... 1461 Range Hoods & Accessories...1470-1473 Appliance Repair Parts...1473-1489