AS950 PORTABLE SAMPLERS
|
|
- Erik Jordan
- 6 years ago
- Views:
Transcription
1 AS950 PORTABLE SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Portable Sampler makes programming, data transfer and operation more intuitive and virtually error-free. Easiest and Most Intuitive Operation The large full color display and intuitive programming give you access to all your programmable criteria on a single screen - eliminating scrolling through menus and supporting error-free operation. Most Convenient Data Transfer and Programming Available The AS950 is the only sampler that utilizes a USB drive to upload and download data and copy programs from one sampler to another. Confidence in Your Sampling Process The program status screen instantly communicates alarms, missed samples and program progress for quick and easy troubleshooting. Field Convertible for Compact or Discrete Sampling Weighing only 28 pounds (12.7 kg), the AS950 Portable Sampler is designed for accuracy and convenience. Quickly switch between composite and discrete sampling in the field. Configurable for single- or multiple-bottle applications, it is specifically designed for use in 18-inch manholes. Easy Maintenance at Low Cost Spring-mounted rollers provide long tubing life keeping maintenance costs low. The desiccant and pump tubing can easily be accessed; the replacement is possible without any tools. The rugged see-through pump cover is made for a quick visual inspection.
2 2 AS950 Portable Samplers Sampling Features Dual Programs Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers Sampling Modes Pacing: Time Weighted, Flow Weighted, Time Table, Flow Table, Event Distribution: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle Run Modes Continuous or non-continuous Status Screen Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature Alarms Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as ph, level and power supply voltage. Manual Sample Initiates a sample collection independent of program in progress Automatic Shutdown Multiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected) Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container. Sample Volume Programmable in 10-mL (0.34 oz) increments from 10 to 10,000 ml (3.38 oz to 2.6 gal) Interval Between Samples Selectable in single increments from 1 to 9,999 flow pulses (momentary contact closure 25 ms or 5 to 12 Vdc pulse; 4-20 ma interface optional), or 1 to 9,999 minutes in one minute increments Set Point Sample Trigger When equipped with flow sensor or ph/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded Datalogging SAMPLE HISTORY Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery) MEASUREMENTS Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval EVENT LOG Stores up to 2000 entries. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, sensor communication errors, cooling failed, heating failed, thermal error corrected Diagnostics View event and alarm logs as well as maintenance diagnostics
3 AS950 Portable Samplers 3 AS950 Portable Sampler Sampler Housing Impact resistant ABS plastic, 3-section construction Double-walled base with 1 in. (2.54 cm) insulation, direct ice contact with bottles Temperature Operating: 0 to 49 C (32 to 120 F Power Requirements AC Power Backup (Pump Controller Only) Solar Power Panel/Backup Dimensions Liquid Crystal Display (LCD): -10 to 70 C (-14 to 158 F) Storage: -40 to 60 C (-40 to 140 F) 12 Vdc supplied by optional a/c power converter or battery. Average current with pump running: 2.25 amps dc Rechargeable 6 amp-hour gel lead acid battery takes over automatically with AC line power failure. Integral trickle charger maintains battery as full charge (factory installed option) 12 Vdc regulated supply voltage, 5 watts minimum; optional 12 Vdc lead-acid or gel-electrolyte battery backup Standard Base: 50.5 cm x 69.4 cm (19.9 x 27.3 in.) Compact Base: 44.1 x 61 cm (17.4 x 24 in.) Composite Base: x cm (19.8 x 31.4 in.) Weight Standard: 15 kg (35.6 lb.) with (24) 1-L polyethylene bottles; 14.8 kg (32.6 lb.) with 10 L (2.5gal) polyethylene bottle Compact Base: 12.2 kg (27 lb.) with (24) 575-mL polyethylene bottles; 12.9 kg (28.3 lb.) with 10 L (2.5-gal) polyethylene bottle Composite Base: 15 kg (36 lb.) with (1) 21 L (5.5 gal) polyethylene bottle AS950 Controller Housing Graphics Display User Interface Program Languages Program Lock Memory Communications AUX port inputs Certifications Sample Containers PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant 1/4 VGA, Color; self-prompting/ menu-driven program Membrane switch keypad with 2 multiple function soft keys Chinese, English, French, German, Italian, Spanish, Portuguese Access code protection prevents tampering Sample history: 4000 records; Data log: 325,000 records; Event log: 2000 records USB and optional RS485 (Modbus) One 0/4-20 ma input for flow pacing CE, UL Standard Base Capacity (24) 1 L (0.26 gal) polyethylene or (24) 350-mL (11.83 oz) glass bottles (8) 2.3 L (0.6 gal) polyethylene or (8) 1.9 L (0.5 gal) glass bottles (4) 3.8 L (1 gal) polyethylene or (4) 3.8 L (1 gal) glass bottles (2) 3.8 L (1 gal) polyethylene or (2) 3.8 L (1 gal) glass bottles (1) 21 L (5.5 gal) polyethylene composite bottle or (1) 15 L (4 gal) polyethylene composite bottle or (1) 20 L (5.25 gal) polyethylene or (1) 10 L (2.5 gal) polyethylene or (1) 10 L (2.5 gal) glass Compact Base Capacity (24) 575 ml (19.44 oz) polyethylene bottles (8) 950 ml (32.12 oz) glass bottles (1) 10 L (2.5 gal) polyethylene bottle (1) 10 L (2.5 gal) glass bottle Composite Base (1) 21 L (5.5 gal) polyethylene bottle Ice Capacity Compact Base: 3.9 kg (8.5 lb.) with (24) 575 ml PE bottles Standard Base: 14.5 kg (32 lb.) with (24) 350 ml glass bottles
4 4 AS950 Portable Samplers Sample Pump and Strainer Sample Pump High-speed peristaltic, dual roller, with 0.95 ID x 0.16 OD cm (3/8 ID x 5/8 in. OD) pump tube Pump Body IP37, polycarbonate cover Vertical Lift 8.5 m (28 ft) using 8.8 m (29 ft) maximum of 3/8-in vinyl intake tube at sea level at 20 to 25 C (68 to 77 F) Tubing Pump tubing: 9.5 mm ID x 15.9 OD mm (3/8-in ID x 5/8-in. OD) silicone Intake tubing: 1.0 to 4.75 m (3.0 to 15.5 ft) minimum length, ¼-in. or 3/8-in. ID vinyl or 3/8-in. ID Teflon -lined polyethylene with protective outer cover (black or clear) Sample Volume Repeatability (typical) ±5% of 200 ml sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation Sample Volume Accuracy (typical) ±5% of 200 ml sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation Transfer Velocity (typical) 0.9 m/s (2.9 ft/s) with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8-in. vinyl intake tubing, 21 C (70 F) and 1524 m (5000 ft) elevation Pump Flow Rate 4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with 3/8-in intake tube typical Internal Clock ±1 second per day at 25 C (77 F) Intake Strainers: Choice of Teflon and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications Purge: Air purged automatically before and after each sample; duration automatically compensates for varying intake line lengths Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt Dimensions The AS950 Portable Sampler is designed for indoor or outdoor use. No secondary enclosure is required when operated within the specified temperature range. The sampler consists of three main sections the top cover, the center control system, and the bottle/ base section held together by stainless steel latches which serve as the connection point for the optional suspension harness. The lockable top cover protects the controller from extreme weather and unauthorized use. Compact Base Standard Base Composite Base
5 AS950 Portable Samplers 5 Ordering Information AS950 Portable Sampler Bundles Includes portable base,12v battery, sample bottle(s), vinyl intake tubing (25 ft.), and Teflon/stainless steel strainer. To order different combinations, please contact Hach Company. ASP.CXXXC121XX Portable Compact Sampler with AS950 controller, (1) 2.5 gal polyethylene bottle ASP.CXXXC161XX Portable Compact Sampler with AS950 controller, (24) 575 ml polyethylene bottles and distributor arm ASP.CXXXS121XX Portable Standard Sampler with AS950 controller, (1) 2.5 gal polyethylene bottle ASP.CXXXS141XX Portable Standard Sampler with AS950 controller, (24) 1 L polyethylene bottles and distributor arm Controller and Base Options 8975 Compact Insulated Base 8976 Standard Insulated Base 8561 Composite Insulated Base Bottle Options Gallon Glass, with Teflon-lined cap Gallon Polyethylene, with cap Gallon Polyethylene, with cap 2214 Set of (2) 1 Gallon Glass, with Teflon lined caps 2215 Set of (2) 1 Gallon Polyethylene, with caps 2216 Set of (4) 1 Gallon Glass, with Teflon lined caps 2217 Set of (4) 1 Gallon Polyethylene, with caps 2348 Set of (8) 950 ml Glass, with Teflon lined caps 1369 Set of (24) 575 ml Polyethylene, with caps 737 Set of (24) 1 Liter Polyethylene, with caps Bottle Accessories 2620 Retainer for (12) 950 ml Glass Bottles 2189 Retainer for (24) 350 ml Glass Bottles 1422 Retainer for (8) Glass, (8) Poly, (24) 575 ml Poly, and (24) 1 Liter Poly Bottles 2347 Retainer for (8) 950 ml Glass Bottles 2190 Retainer for 1 Gallon Glass and 1 Gallon Polyethylene Bottles 1502 Container Support 8996 Retainer/Full Container Shut-off Distributors 8582 Distributor with Arm for 24 Bottle, Standard Base and 12 Bottle Compact Base 8580 Distributor with Arm for 24 Bottle Compact Base 8584 Distributor with Arm for 2, 4 and 8 Bottle Standard Base and 8 Bottle Compact Base Intake Tubing and Strainers ft. Vinyl Intake Tubing, 3/8-in ID ft. Teflon Lined Polyethylene Tubing, 3/8-in. ID (requires Prod. No Connection Kit) 926 Strainer; Teflon/Stainless Steel 2070 Strainer, 316 stainless steel 2071 Strainer, for shallow depth applications, 316 stainless steel 2186 Connector Kit, for Teflon lined polyethylene tubing 4652 Strainer, high velocity and shallow depth Pump Tubing Pump Tubing, 15 ft Pump Tubing, 50 ft Pump Tube Insert Pump tube insert, non-contact liquid detect Factory Installed Options (contact sales representative) Two Sensor Ports Accepts Hach digital Differential ph, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors Rain/RS485 Port Accepts Hach Rain Gauge (not included) or can be used as RS485 communications Non-Contact Liquid Detect Sample volume accuracy for applications that require complete tubing replacement Inputs/Outputs IO9001 Module (connects through auxiliary port) single relay (high voltage) IO9004 Module (connects through auxiliary port) includes multiple 0/4 20 ma outputs and inputs for recorded measurements and to receive measurements from external instruments, four low voltage, contact closure, and four relays controlled by alarm events Accessories 1355 Suspension Harness (suspends the sampler) 9542 Manhole Support Bracket/Spanner, 18 to 28 in Manhole Support Bracket/Spanner, 28 to 48 in Manhole Support Bracket, 18 to 27 in Weatherguard Fiberglass Enclosure, 89 x 89 x 86 cm (35 x 35 x 34 in.) 6992 Weatherguard Fiberglass Enclosure, 91 x 66 x 135 cm (36 x 26 x 53 in.) Solar Module, with 10 W panel and 12 Vdc regulator Solar Module, with 20 W panel and 12 Vdc regulator Solar Module, with 30 W panel and 12 Vdc regulator Solar Module, with 40 W panel and 12 Vdc regulator Solar Module, with 50 W panel and 12 Vdc regulator Battery, 12 volt, Lead Acid US Charger, 115V, Lead Acid US Power Supply, V, US plug USB Cable, A to A DOC Apr15 HACH COMPANY World Headquarters: Loveland, Colorado USA United States: tel fax orders@ Outside United States: tel fax int@ Printed in U.S.A. Hach Company, All rights reserved. In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time.
AS950 REFRIGERATED SAMPLERS
AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,
More informationAS950 ALL-WEATHER REFRIGERATED SAMPLERS
AS950 ALL-WEATHER REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 All-Weather Refrigerated
More information900MAX PORTABLE SAMPLERS
900MAX PORTABLE SAMPLERS Applications Wastewate Collections The Hach Sigma 900MAX Portable Sampler s advanced technology and comprehensive customer service can be summarized in five key concepts: accuracy,
More informationIsco 3700ZR Sampler. Manual Set
Isco 3700ZR Sampler Manual Set Assembly #60-2744-045 Copyright 2001. All rights reserved, Teledyne Isco Revision D, December 14, 2012 This set of manuals supports the Isco 3700ZR Refrigerated Sampler.
More informationGlobal Water Instrumentation, Inc.
WS700R Refrigerated Wastewater Sampler Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail
More informationModel S5000 & S5200 Stationary Composite Vacuum Samplers (Refrigerated)
Environmental Inc Model S5000 & S5200 Stationary Composite Vacuum Samplers (Refrigerated) Reliable Representative Samples Vacuum samplers have been supported in multiple tests as a superior form of sampling,
More informationDate SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1
Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. A modular single or dual channel controller that works with analog sensor modules and/or digital sensors. 1.2 Measurement Procedures A. Microprocessor-based
More informationFree Chlorine Measuring System
Product Data Sheet PDS 71-FCL/rev.H September 2008 Model FCL Free Chlorine Measuring System COMPLETE SYSTEM INCLUDES sensor, connecting cable, analyzer, and flow controller. CONTINUOUS ph CORRECTION eliminates
More informationInstallation and Operation Guide
Installation and Operation Guide Part #69-2953-031 Copyright 1998. All rights reserved, Teledyne Instruments, Inc. Revision V, March 2016 Foreword This instruction manual is designed to help you gain
More informationTouchpoint Plus. A whole new control experience
Touchpoint Plus A whole new control experience Touchpoint Plus Delivering reliable control Honeywell reliability from the most trusted experts in gas detection Built-in battery backup for constant uptime
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationDIESEL Engine Fire Pump Controllers Features
1-1 Product Description The FD100 Diesel Engine Controller is designed to control and monitor 12 or 24 volt, diesel fire pump engines. All models are listed by UL and ULC, and approved by Factory Mutual
More informationGas Detection. Touchpoint Plus. A whole new control experience
Gas Detection Touchpoint Plus A whole new control experience Touchpoint Plus Touchpoint Plus brings a whole new control experience to your small system of gas detectors. Touchpoint Plus is an easily configurable,
More informationDIESEL Engine Fire Pump Controllers Features
September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller.
More informationOmniguard 4: Features
OMNIGUARD 4 The clear choice for monitoring and documenting Vacuum and Pressure in a containment area. Ideal for Asbestos, Lead and Mold abatement and Clean Room monitoring. Omniguard 4: Features The Omniguard
More informationImprove Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...
Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable
More informationUSER MANUAL USB Multi-Function Datalogger Model RHT35
USER MANUAL USB Multi-Function Datalogger Model RHT35 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech multi-function, easy-to-use, portable
More informationUSB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger
USER MANUAL USB Multi Function Dataloggers RHT30 Humidity/Temperature Datalogger TH30 Dual Temperature Datalogger Additional User Manual Translations available at www.extech.com Introduction Thank you
More informationSeries 5000 Hydrazine Analyzer Model 60002
Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement
More informationDIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers
DIESEL Engine Fire Pump Controllers Features FD120 Diesel Engine Controllers 1-1 March 2013 Diesel Product Description The DIESEL Plus Fire Pump Controllers from Eaton Corporation are designed to control
More informationMAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft
MAX ARM Heavy Duty Linear Actuator for Residential / Commercial use Super quiet Solar ready Large diameter stainless steel output shaft MAX AC control box DSP Control 2 Years Warranty or 100,000 Cycles
More informationCONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH
CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source
More informationTouchpoint Plus. A whole new control experience
Touchpoint Plus A whole new control experience Touchpoint Plus Delivering reliable control Honeywell reliability from the most trusted experts in gas detection Built-in battery backup for constant uptime
More informationGasAlertMicroClip X3 Specifications
GasAlertMicroClip X3 Specifications The instrument must satisfy the following: Physical Specifications Size (h x w x d) Physical size shall be no larger than 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.2 cm Weight
More informationFDF Foam Pump Controllers Features
FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationPowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.
PowerWizard Providing Safe Control of Your Generating Set The Fg Wilson PowerWizard range of digital control panels combine straight forward menu navigation with advanced metering and protection technology.
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationTECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014
January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,
More informationDate SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1
Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. Phosphate process analyzer for semi - continuous monitoring of phosphate in water. 1.2 Measurement Procedures The phosphate analyzer shall be
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationRACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.
RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are. he Verbatim Gateway from RACO, the remote monitoring and alarm specialists, allows you to use TouchTone telephones anywhere
More informationAquaLynx 200 ADX. Monitoring and Control System. Background. Operation
AquaLynx 200 ADX Monitoring and Control System The RODI Systems AquaLynx 200 ADX is a unique monitoring system for water treatment applications. The AquaLynx 200 ADX offers a dependable yet affordable
More informationfor Drinking Water Systems
Water Quality Measurement Solutions Instrument Overview Online UV%Transmission Analyzer for Drinking Water Systems HF scientific developed the AccUView UV%Transmission Analyzer specif ically to f ill the
More informationUltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW
12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes
More informationClamp-on ultrasonic flow and energy meters for liquids
Model TFX Ultra Clamp-on ultrasonic flow and energy meters for liquids - Features Reduced material cost: Clamp-on sensor eliminates the need for in-line flanges, pipe fittings, strainers and filters Reduced
More informationCLARITY II TURBIDIMETER
Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1
More informationSelf-contained and intrinsically safe wireless stand-alone multi-point gas detector.
Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationLMR Electric Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationTHX-DL Data Logger USER & INSTALLATION MANUAL V
THX-DL Data Logger USER & INSTALLATION MANUAL V1.2012 www.thermomax-refrigeration.com Contents PRESENTATION Summary of Features 2 INSTALLATION Safety Precautions 4 THX Unit 4 Sensors 4 Alarm Relay 4 Power
More informationFT60 Reduced Voltage - Autotransformer
1-1 Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer
More informationACP10 & ACP50 Security Systems
ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel
More informationLiquid Helium Level Instruments
Liquid Helium Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics Model 135 Liquid Helium Level Monitor... Sample-and-Hold Level Sensing
More informationPowerWizard. Level 1.0 & Level 2.0 Control Systems Training
PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control The Best Choice for Asset Protection What suppression and extinguishant control panel would you choose to protect the literary collection of an entire nation? 47
More informationReliably Advanced Extinguishing Control
Reliably Advanced Extinguishing Control 14 years. 60 countries. Still Advanced. We re the same people, with the same commitment to excellence and customer satisfaction and now we have a brand that reflects
More informationSCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview
Micro SCM Streaming Current Monitor A Watts Water Technologies Company Instrument Overview The instrument consists of the Analyzer and the SCM sensor. Analyzer The Analyzer The monitor has a built in graphic
More informationGas Controller Module GC-06
Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,
More informationLMR Electric Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A
SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist
More informationCONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.
CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse
More informationTransfer Switch Features
1-1 Product Description The Automatic Transfer Switch Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer
More informationModel LTN-3R Outdoor Rated Uninterruptible Power System Single Phase
Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics
More informationHOBO U30 Remote Monitoring Systems
onset HOBO U30 Remote Monitoring Systems Web-based environmental monitoring All electronics housed within a research-grade, tamperproof enclosure Setup is quick and easy with plug-and-play sensors GSM
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationTransfer Switch Features
1-1 Product Description The Automatic Transfer Option may be added to any FD type Fire Pump Controller whenever automatic transfer from normal to alternate power is required. The automatic Transfer and
More informationEasyLog Data Logger Series
EasyLog Data Logger Series Overview EasyLog model EL-USB series products are a line of low cost, compact, battery-operated data loggers with built-in memory and USB interface. Each product in the line
More informationHigh Pressure Conductivity Monitor
Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY
More informationEAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility
EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to
More informationPEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K
PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)
More information5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors
Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now
More informationFire Pump Controllers Foam (Additive) Controllers
Fire Pump Controllers Foam (Additive) Controllers Diesel Additive (Foam) Pump Controllers 1.4 Foam (Additive) Fire Pump Controllers FDF20 Foam (Additive) - Limited Service... FDF30 Foam (Additive) - Across-the-Line...
More informationQUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions
QUANTURA DISHWASH DOSING SYSTEMS revolutionary dispensing solutions QUANTURA BRIGHTWELL DISPENSERS NEW RANGE OF DISHWASH DOSING SYSTEMS Reliable and efficient chemical dosing systems ensure that commercial
More informationINSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)
1 INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS) SECTION TITLE PAGES 1 Introduction and Basic Operation 2-3 2 Cleaning & Storing 4 3 Basic
More informationDigital Control Systems & Remote Communications Options
Digital Control Systems & Remote Options PowerWizard Providing Safe Control of Your Generating Set PowerWizard 1.0 and 2.0 The Olympian PowerWizard range of digital control panels combine straight forward
More informationWASTEWATER Online UV%Transmission Analyzer
Water Quality Measurement Solutions Online UV%Transmission Analyzer Detailed Specifications Instrument Overview With over 30 years of optical design technology expertise HF scientific has developed it's
More informationGG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual
GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified
More informationSCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification
February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5
More informationHydrazine Analyzer Series 2171 Specifications
Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationSIL 2. Ultima X Series Gas Monitors CERTIFIED
Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection
More informationMark 25 Ultrapure Water Conductivity Analyzer
Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects
More informationThe ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features
990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has
More informationTechnical Data Submittal Documents
Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Documents Model PD - FM Diesel Engine Driven Fire Pump Controller Contents: Data Sheets Dimensional Data Wiring Schematics Field
More informationDREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
More informationPlate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series
Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers
More informationUniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser
Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser >10h Operation with Li-Ion Battery Pack Smart Autozero without Removal the Probe CO Dilution up to 10% Stores up to 250 Complete Analysis
More informationGilian Air Sampling Products. The World s Most Reliable Air Sampling Equipment
Gilian Air Sampling Products The World s Most Reliable Air Sampling Equipment Overview of Sensidyne Established in 1983 Joined the Schauenburg Group in 2008 Major Product Groups: Air Sampling * Fixed Gas
More informationProduct Specifications
Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specifications Procurement Specifications INTREPID MicroPoint Cable System Perimeter Detection
More informationAL800ULADA. NAC Power Extender. Installation Guide
AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery
More informationMultiview Monitor / Controller
FEATURES: Bright/sunlight readable 7.0 LCD touch screen. Displays large, easy to read values, set points, room status, modes and alarms Up to six fully configurable Icons including: Environmental points
More informationIndustrial Grade Gas Detection
Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A
More informationProduct Specification
Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specification INTREPID MicroTrack Buried Cable Perimeter Intrusion Detection System System
More informationCO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE
CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE GasAlertMicro 5 IR from Refer to for more details. Manual provided on CD with unit at time of purchase 2 Table of Contents Getting Started.
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More informationGASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL
GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..
More informationCable Actuated Sensor Industrial User Scalable VDC Output
Cable Actuated Sensor Industrial User Scalable VDC Output User Signal Adjustable Stroke Range to 175 inches (3 meters) User Selectable 0 5, 0 10, 5 +5, 10 +10 VDC Output Designed for Outdoor & IP67 environments
More informationNU2 Smart Power Supply (SPS) Manual
GENERAL The Smart Power Supply (SPS) is an innovative Quad Output, field programmable power supply. Each of the four outputs can provide four Amps for a total of sixteen Amps in either 12VDC or 24VDC.
More informationRANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...
More informationRANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE
More informationModels 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers
Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance
More informationPortable central unit for several parameters
MultiTracker Portable central unit for several parameters Parameter options: Dissolved Oxygen Sludge Blanket Suspended Solids All sensors are members of the new Cerlic Multiseries family. n Quick and reliable
More informationelite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems
5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification
More informationEthernet General Purpose
Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3
More informationLift Station Level Controller
Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...
More informationAccuBrine automated brine maker Technical Specifications
Cargill Deicing Technology AccuBrine automated brine maker Technical Specifications All 4 models included Automated Blending System Model (ABM) Automated Blending Remote Truck Fill Model (ABRTF) Automated
More information