Technical Bulletin IG018 Quanex Building Products
|
|
- Wilfrid Webster
- 6 years ago
- Views:
Transcription
1 Systems Unit Testing and QC Procedures for Dura Flexible Spacers Quality Control Tests I. Dew Point Determination for Flexible Spacer IG Units II. Quick Test or Ice Cube Test III. V-45 Initial Adhesion Test IV. Slosh Test I. Dew Point Determination for Flexible Spacer IG Units This Quality Control Test is conducted to ensure that the desiccant in the Flexible Spacer is active and capable of drying the hermetically sealed air space within the IG unit. Purpose: To measure the rate at which spacer desiccates a standard sized airspace. Required Materials 2 pieces of clean, dry clear float glass 5 (127mm) square Dew point apparatus. See Figure 1. A thermometer with a range of at least +32 to -100 F (0 to -73 C) Dry ice (solid carbon dioxide) -- powdered or pulverized Isopropyl alcohol A timing device with second indicating capability A sample of Flexible Spacer just removed from its packaging container. Procedure 1. Using the two small lites of clean, dry clear float glass and the Flexible Spacer sample, assemble a small IG unit. Compress the unit and seal the final corner. 2. Age the sample unit for 2 hours at 77 F (25 C). 3. Prepare the dew point apparatus with isopropyl alcohol and dry ice, and adjust the system to 0 F (-18 C). 4. Apply a film of alcohol to one face of the sample unit, and then place the brass section of the dew point apparatus in contact with this face for 3 minutes. Maintain the dew point apparatus at the desired test temperature by the addition of more dry ice as required for this 3-minute period. Technical Bulletin IG Remove the dew point apparatus after 3 minutes and apply another film of alcohol to the dew pointed area, and as quickly as possible, view the sample from above by means of a light transmitted through the sample from beneath. If condensation or frost has formed on the second surface of the top lite of glass, then the dew point of the sample is higher/warmer than the tested temperature. See Figure 1 for a configuration of the dew point test. Continued next page...
2 Technical Bulletin IG018 Unit Testing and QC Procedures for Dura Flexible Spacers 6. Repeat steps 1 to 5, adjusting the test temperature by 10 F (5 C) up or down as required, waiting 5-10 minutes between tests or until the condensation from the previous test has flashed off. 7. Repeat parts 1 to 5 after 24 hours aging at 77 F (25 C) starting at -40 F (-40 C) and adjusting the temperature up or down as required by 10 F (5 C). Figure 1: After removing the dew point apparatus, look for condensation or frosting on the inside surface of the glass as shown. Duraseal /Duralite /Decoseal /Edgetherm FS Performance Requirements 2 hour aged sample test should have a dew point of 20 F (-7 C) or lower. 24 hour aged sample test should have a dew point of -20 F (-29 C) or lower. Microseal DS Performance Requirements 4 hour aged sample test should have a dew point of <32 F (0 C). 24 hour aged sample test should have a dew point of 14 F (-10 C) or lower. In the event that the test sample does not meet the above requirements, immediately retest this packaging 4 wraps further down in the package. If additional stock is available set aside this drum and open another drum until the retest has been completed. In the event that the retest results do not meet the requirements, your Quanex Sales Representative should be contacted and this packaging should be set aside. See Notes 1-3 Note #1: For a comparison evaluation, a dew point run on a single lite of glass would show a deposit at a temperature of 32 F (0 C). See: Flexible Spacer Desiccant Dew Point Draw Down - Quick Test - (Ice cube test) Note #2: If the test lites of glass are not fully dried or if the samples are made during a high humidity period, the 2-hour results may not pass. A retest should be started with added care taken regarding the drying of the lites of glass. Note #3: Dew Point is recorded as the last boundary at which no condensation or frost is deposited on the 2nd surface of the top lite of glass, while with a 5 F (2.5 C) drop of the test temperature, a deposit is formed. Continued next page...
3 Unit Testing and QC Procedures for Dura Flexible Spacers II. Quick Test or Ice Cube Test This test is a quicker, yet less precise means of qualifying the dew point development of an IG unit than the Dew Point Draw Down Test detailed above. It requires no dry ice or frost point device. Its purpose, however, remains the same, and is to ensure that the desiccant in the Flexible Spacer is active and capable of drying out the hermetically sealed air space. Equipment and Supplies 2 pieces of clean, dry clear float glass 5 (127 mm) square Ice cubes with at least 1 flat side Water A timing device with second indicating capability A sample of Flexible Spacer just removed from its packaging container Procedure 1. Using the two 5 (127 mm) lites of clean, dry clear float glass and the sample to be tested of Flexible Spacer, assemble a small insulating glass unit. 2. Compress the unit and seal the final corner. 3. Age the sample unit for 2 hrs. for Duraseal/Duralite/Decoseal/Edgetherm FS, 4 hrs. for Microseal DS hours at 77 F (25 C). 4. Place a small amount of water on the top lite of the small sample unit and then hold the flat side of an ice cube (32 F / 0 C) in place on the sample unit for 3 minutes. 5. Remove the ice cube after 3 minutes and apply another film of water to the dew pointed area. Then as quickly as possible, view the sample from above by means of a light transmitted through the sample from beneath. If no condensation has formed on the second surface of the top lite of glass, then the dew point draw down on this Flexible Spacer would be considered good. If condensation formed, the desiccant activity of the spacer would be in question. If condensation is observed, redo the test. Technical Bulletin IG Hold the sample unit for 24 hours and repeat the dew point test, as well as associated production. Performance Requirements After 2 hours for Duraseal/Duralite/Decoseal/Edgetherm FS or 4 hours for Microseal DS there should be no condensation formed in the sample unit. If after these times, there is condensation formed, the test should be repeated and the first sample tested again after 24 hours aging at 25 C (77 F). If after 24 hours condensation still forms, the associated Flexible Spacer should not be used. Contact your Quanex Sales Representative. Continued next page...
4 Technical Bulletin IG018 Unit Testing and QC Procedures for Dura Flexible Spacers III. V45 Initial Adhesion Test This test is conducted to ensure adequate initial adhesion between clean, dry glass and Dura Flexible Spacer s bondline sealant; general use is in detecting unplanned glass or spacer contamination prior to IG unit release. Equipment and Supplies 2 pieces of clean, dry glass minimum thickness dsb/3 mm clear float, approximately 12 (305 mm) square Sample quantity of Flexible Spacer, just removed from packaging, but conditioned to F (21-25 C). Note: filler strips approximate length 5 (130 mm) Use of the production heated glass press Glass cutter Safety glasses, safety sleeves and gloves to safely handle glass Procedure 1. Apply the 12 (305 mm) sample of Flexible Spacer on two opposite edges (a) of the clean, dry pieces of clear float glass in the fashion used in production; on the other two adjacent sides (b), use pieces shorter than the glass (approximately 5 (130mm). Reference Fig.1. Figure 1: Assemble with fill strips Figure 2: Example V-45 rotation in test 2. Place the lite of glass on top of the applied spacer and slightly press by hand to set the unit, and then compress the unit to nominal using the production press. Press to the airspace dimension specific to the spacer used, , , being sure to achieve the correct exit temperature of 110 F-120 F (43 C-49 C). Continued next page...
5 Unit Testing and QC Procedures for Dura Flexible Spacers 3. Allow the assembly to cool to 75 F (24 C) for approximately 30 minutes after exiting the press. Then, wearing safety glasses gloves, and sleeves score the top lite with glass cutter (Ref. Figure 1 score lines) then press up on the score lines to break the glass. Reference Figure 2. Slowly hinge the unit by pulling up and rotating first one half of the fractured lite, opening it to 45 over a full 5 seconds. Check the bond line for adhesion by examining the black bond line adhesive and comparing it to the photos. 4. Figure 3 Acceptable, 4 not acceptable. Note: When you perform the V-45 test you may see an approximate.050 (1.3mm) adhesion loss to the interior of the test sample. This is the Top Coat area which is not part of the test requirement. Requirement is for >50% of bondline to remain adhered, as viewed through glass. 5. Repeat the procedure with the second half of the fractured top lite, also as shown in Figure 2. Performance Requirements To meet Acceptable standards as in Figure 3: If there are areas that exhibit a bondline shown in Figure 4. Not acceptable, verify that the glass used is completely clean and dry using the slosh test # IV, below. Retest by assembling another sample. Ensure that the applicator is not touching or otherwise contaminating the bond line when the Flexible Spacer is being applied. Ensure that the glass is opened slowly to 45 utilizing the full 5 seconds. If there is a second failure in this test, place this material on hold and contact your Quanex Technologies Sales or Technical Service Representative. Passing Pattern B: >50% adhesion area remaining adhesion loss bond line Top view from outside of glass, after timed flex of 45 adhesion loss bond line Failing Pattern A: <50% adhesion area remaining Technical Bulletin IG018 Figure 3 Figure 4 Continued next page...
6 Technical Bulletin IG018 IV. Slosh Test Unit Testing and QC Procedures for Dura Flexible Spacers The Slosh Test is an indicator of the cleanliness of glass used in the production of IG units. It is imperative that glass be free of contaminants-both particulate and chemical in order to produce high quality, durable units. Any contaminant can affect the long-term adhesive properties of IG seals. Detergents can be particularly insidious; an invisible layer of glass washer detergent that remains on the glass may cause premature failure of the IG unit. Detergents dissolved in water, will froth and produce suds when the liquid is agitated. This property can be exploited to test for glass cleanliness. Conduct the following frequently, such as at the beginning of each shift for example. Equipment and Supplies 2 pieces of clean, dry clear float glass for any production size Water A small, clean jar Procedure 1. Assemble a small (14 x 20 or other convenient size) Flexible Spacer IG unit. 2. After compression, leave the final corner open, and with the IG unit stood on end, pour clean tap water into the hole until it is about ¼ (6mm) deep. 3. By manipulating the IG unit, run the water all over (i.e. rinse) both interior surfaces of the glass. The purpose is to pick up any water-soluble contaminant and detergent residues that may have been deposited on the glass surfaces. 4. Slosh the water back and forth within the IG unit in an attempt to produce froth. Alternatively, transfer the rinse water to a clean jar that is easier to shake. If desired, a second jar can be filled with an equal amount of clean tap water and used as a control. 5. Bubbles in clean water will disappear when shaking stops providing an effective comparison, while detergent froth will remain visible when the agitation is stopped. 6. Also look for water that beads very sharply like water on a freshly waxed car. This indicates that while detergent made by rinsed, there may be contaminants that increase surface energy, also preventing good adhesion. Contaminants such as silicones, oils and waxes fall into this category. V. QC Records The following QC record sheets are included as IG 018 Appendix A: Dew point development Adhesion Unit rejects in house Receiving & stock Random finished unit inspection Note: These record sheets can be requested as Excel spreadsheets that can be modified for specific account needs.
7 Appendix A - Dew Point Development Technical Bulletin IG018
8 Technical Bulletin IG018 Appendix A - QC Finished Product Inspection by Exception
9 Appendix A - Record of Flexible Spacer Deliveries Technical Bulletin IG018
10 Technical Bulletin IG018 Appendix A - Daily Inspection of Flexible Spacer IG Units
11 Unit Testing and QC Procedures for Dura Flexible Spacers Rev. # Revisions Made Rev. Date 6 Corrected Truseal to Quanex Edits to page 5 (labeled drawings and reverse placement) Edits to pages 4 and SBU to Quanex, Formatting Formatting Reissue dates & Original Document created Technical Bulletin IG018 Quanex IG Systems 800 Cochran Avenue Cambridge, OH T F
Duralite and Duraseal Application Manual
Insulating Glass Systems Duralite and Duraseal Application Manual Table of Contents DURASEAL AND DURALITE : HISTORY AND DESCRIPTION... 2 BASIC USE... 2 FEATURES... 2 HOW EACH ELEMENT IN DURASEAL AND DURALITE
More informationAGC Sputter Coating Glass Processing Guidelines
TECHNICAL SERVICES DOCUMENT TSD-217 AGC Sputter Coating Glass Processing Guidelines Introduction Comfort Select and Energy Select are Low-Emissivity glasses manufactured by AGC Glass Company North America.
More informationSELF-ADHESIVE FILM INSTALLATION GUIDE
SELF-ADHESIVE FILM INSTALLATION GUIDE Table of Contents Important Information... 2 Tools & Materials Required... 3 Installation Procedure... 5 Part 1: Preparing the Smart FILM... 5 Part 2: Clean the Glass
More informationGuide for Thin Film Evaporation Edited 7/22/13 by Stephen Albright, BJAM & Steven Palefsky
Guide for Thin Film Evaporation Edited 7/22/13 by Stephen Albright, BJAM & Steven Palefsky N.B. This guide is written largely for use with the Thin-Film Tunneling with Superconductors instructional lab.
More informationStress Corrosion Technical Bulletin
Stress Corrosion Technical Bulletin 1. 2. 3. 4. Table of contents Foreword Background Cause and Result Recommendations 4.1 Post Seamer Rinsing 4.2 Can Warmer / Pasteuriser 4.3 Can and End Rinsing 4.4 Can
More informationCLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com
CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY natoli.com PROPER TOOL CLEANING IS CRUCIAL EXTEND TOOL LIFE DECREASE PRESS DOWNTIME REDUCE PRODUCTION-RELATED COSTS IMPROVE TABLET QUALITY Tablet
More informationPDMS Casting Station Supplies
PDMS Casting Station Supplies These are provided by the CNF. Please do not use more than you need. Please do not take extra supplies from the lab. Log onto CORAL each time that you use PDMS and the PDMS
More informationWhirlpool AUTOMATIC ICE CUBE MAKER. User s Instructions & Care and Cleaning Guide MODELS CH E-5R CHS-5R CHE-7R CHS-7R. Part No.
Whirlpool AUTOMATIC ICE CUBE MAKER User s Instructions & Care and Cleaning Guide MODELS CH E-5R CHS-5R CHE-7R CHS-7R Part No. 585102 Rev. A General Information When the desired thickness is reached, the
More informationIntroduction The following illustrated instructions are a generic guide to the internal installation of Safety and Security Films.
TECHNICAL BULLETIN Avery Dennison Interior Safety Films Installation Guide issued: 01/2018 Introduction The following illustrated instructions are a generic guide to the internal installation of Safety
More informationST-1 Surface Treatment
and Adhesion Promotion APPLICATION MANUAL TABLE OF CONTENTS About 1 Laboratory Testing Protocols 2 Manual Scrub Application - rinse 2 Manual Scrub Application - no rinse 3 High Pressure Spray Application
More informationCOMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6
OWNERS MANUAL BOSS COMPRESSED AIR DRYER Distributed by Air & Vacuum Process, Inc. Phone: 281-866-9700 Fax: 281-866-9717 Email: sales@airvacuumprocess.com SAFETY... Page 2 MAINTENANCE... Page 5 INSTALLATION...
More informationPacked With Features. Smart Pulsar controls are conveniently
Packed With Features Filter cartridge is automatically cleaned each time the pedal is operated. Pull-through exhaust fan reduces wear on impeller blades. Unique Air Logic System maximizes air flow to the
More informationVELOPEX PROCESSORS. Always ensure processor is switched off prior to changing chemicals.
VELOPEX PROCESSORS The processor should be placed: Away from any strong light source i.e. daylight from windows or fluorescent lighting In a cool, well-ventilated area max temp 27c for the Intra X26c for
More informationPacked With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated.
Packed With Features Filter cartridge is automatically cleaned each time the pedal is operated. Pull-through exhaust fan reduces wear on impeller blades. Unique Air Logic System maximizes air flow to the
More informationONSITE WASTEWATER EFFLUENT UV DISINFECTION DEVICE MODEL 120 UV UNIT PART #P8888
ONSITE WASTEWATER EFFLUENT UV DISINFECTION DEVICE MODEL 120 UV UNIT PART #P8888 I. CLEARSTREAM MODEL 120 UV UNIT 1. Clearstream manufacturers a UV disinfection unit for wastewater treatment applications.
More informationWHITE PAPER The Importance of Rinsing in Metal Finishing Operations
WHITE PAPER The Importance of Rinsing in Metal Finishing Operations By Steve Rudy, CEF & Sales/Technical Representative The focus or driving force of rinsing is to eliminate contaminants from the surface.
More informationTanis Engine Dehydrator. User s Guide
Tanis Engine Dehydrator User s Guide Model TED-4010E Tanis Aircraft Products PO Box 117 Glenwood, MN 56334 800-443-2136 320-634-4772 www.tanisaircraft.com Copyright 2007 by Tanis Aircraft Products. All
More informationSuperKlean Washdown Products
February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT
More informationTECHNICAL BULLETIN VG4 Series Modular AutoDome
TECHNICAL BULLETIN CCTV AutoDome Modular Camera System Water Ingress July 31, 2009 Issue Severity: High: Act immediately Medium: Bosch Security Systems strongly recommends you take the action(s) described
More information1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol
1. Table of Contents............................................................................................ 2 1.1 0.1 VisiJet Materials Overview............................................................................
More informationINSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU
INSTRUCTION MANUAL Balboa 500Z-Series Operation Guide Initial Start-up Your spa will enter Priming Mode ( ) when it is energized. During Priming Mode, press Jets button(s) repeatedly and be sure all pumps
More informationPOLAR ICE TRAY. Square Bamboo Series. User Manual
POLAR ICE TRAY Square Bamboo Series User Manual Contents The Characteristics of Polar Ice... 3 What makes Polar Ice Unique?... 3 The Concept of Polar Ice... 3 Precautions... 4 Composition... 6 How to Make
More informationMuskogee Public Schools Custodial Procedures for Floor Care
FLOOR CARE ENTRANCE MATS PURPOSE OF ENTRANCE MATS A. Exterior Mats a. Remove sand and gravel from shoes prior to entering the building. b. Minimize the amount of abrading material that will scratch and
More informationPDS 2010 Parylene Coater SOP
PDS 2010 Parylene Coater SOP PDS 2010 Parylene Coater SOP Page 1 of 11 1. Scope 1.1 This document provides the procedures and requirements to deposit a parylene film, using the Specialty Coating Systems
More informationMassachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI)
Rev ECO Description Author Approved Date A 37-428 Initial Release M Gabutti RFGoeke 10/19/2016 D Riley Massachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI) Precision
More informationREGULAR MAINTENANCE AND CARE
NOTE: For all products read the entire product label before using. Use only as directed. Always test in a small inconspicuous area with a 24-hour cure time to determine ease of application and desired
More informationFiber Optic Connector Cleaning and Inspection Kit Instructions
Instruction Sheet 860376037 Rev E, March 2018 Fiber Optic Connector Cleaning and Inspection Kit Instructions General This instruction sheet describes the use of the CommScope Fiber Optic Connector Cleaning
More informationSTONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout
STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout MCI-1104 NOTE: For all recommended products: read the entire product label before using. Use only as directed. Always test
More informationchiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II
chiang mai VINYL WALLCOVERING Type II High Durability (Fed. Spec. CCC-W-408D) Fire Testing Width Pattern Match 54" (137 cm) reverse hang / random match NFPA 255 / ASTM E-84 Tunnel Test: Class A Flame Spread
More informationEkopel 2k. 2K bathtub resurfacing coating. pabrec.com. Description. Package. Advantages. Technical data sheet
Technical data sheet Ekopel 2k 2K bathtub resurfacing coating Description EKOPEL 2K is a high-viscosity two-component self-levelling polymer coating, which is applied for cast iron, steel and plastic bathtub
More informationICE MAKER Use & Care Guide. Table of Contents... 2
ICE MAKER Use & Care Guide Table of Contents... 2 2217247 ICE MAKER SAFETY...2 ICE MAKER INSTALLATION...3 Unpacking...3 Location Requirements...3 Electrical Requirements...3 Leveling...4 Water Supply Connection...4
More informationF Rev. C (June 2010)
HCM450 Cutter Mixer HCM450 CUTTER MIXER MODEL HCM450 ML-134170 ML-134172 ML-134207 ML-134208 ML-134209 ML-136137 ML-136138 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com F-34772
More informationINSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU
INSTRUCTION MANUAL Balboa 500DZ-Series Operation Guide Initial Start-up Your spa will enter Priming Mode ( ) when it is energized. During Priming Mode, press Jets button(s) repeatedly and be sure all pumps
More informationCOOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN
Reclosers MN280020EN Effective October 2015 Supersedes S280-80-14 December 2003 COOPER POWER SERIES Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions DISCLAIMER
More informationLaboratory Glassware Cleaning and Storage
General 07_02_01.004 Dates Active: March 14 th, 2018 - Present Author: Victoria Wickham Laboratory Glassware Cleaning and Storage 1 INTRODUCTION The proper care and cleaning of laboratory glassware is
More informationINSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU
INSTRUCTION MANUAL MVP260 Control Reference Card Non-Circ Operation Initial Start-up When your spa is first actuated, it will go into Priming mode, indicated by Please see the M-7 Installation Instruction
More informationRegular Corona Surface Treater Maintenance Cuts Scrap, Reduces Downtime, Boosts Productivity By Mark Spaulding with Tom Gilbertson and Matt Rajala
Regular Corona Surface Treater Maintenance Cuts Scrap, Reduces Downtime, Boosts Productivity By Mark Spaulding with Tom Gilbertson and Matt Rajala Live Long and Prosper isn t just a saying from Star Trek.
More informationHarmony User s Guide 1
Harmony User s Guide Welcome! Welcome to the Harmony System! The Harmony System provides a superb connection to the prosthetic socket, maintains limb volume to limit pressure points on the limb, and offers
More informationtraining guide TRAULSEN SEAFOOD DISPLAY CABINETS Models: TD078HT
TRAULSEN SEAFOOD DISPLAY CABINETS Models: TD078HT * Traulsen s seafood display cabinets were designed for optimal energy efficiency per Department of Energy requirements to be used with ice. training guide
More informationPET Drying Technology
PET Drying Technology Introduction Industry s increasing demand for clean, reliable sources of high pressure compressed air require that system designers become more educated in dehydration and filtration
More informationFactory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )
Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition ) (Hugo & Russel s Pharmaceutical microbiology) Dr Randa Haddadin ١ Quality: means fitness for purpose, i.e product
More informationTechnical Bulletin. Low-E 4 th surface technology: Guidelines for use. Summary IMPROVING THE PERFORMANCE OF LOW-E GLAZING ATS
Technical Bulletin ATS-193 Summary Low-E 4 th surface technology: Guidelines for use All windows can benefit from higher insulation values (lower U-factor) in all climates and all seasons. Use of Low-E
More informationImportant Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3
User s Manual Index Topic Important safeguards 03 Safety features 05 Parts and accessories 05 Before first use 06 Operating instructions 06 Programme settings 08 Care and cleaning 09 Pressure canning guide
More informationUser instructions. egger EL 1 REF (230 V) REF (115 V)
User instructions egger EL 1 REF 51100 (230 V) REF 51120 (115 V) Please read the instruction manual carefully before working with the device! Please keep the instruction manual at a safe place for later
More informationUNDERSTANDING AND MAINTAINING A GLASS WASHING MACHINE
UNDERSTANDING AND MAINTAINING A GLASS WASHING MACHINE Written by: Bob Lang, Solution Specialist at Billco Manufacturing Inc. --- There are many variables that effect glass cleaning such as water quality,
More informationVVIVID VINYL INSTALLATION GUIDE
VVIVID VINYL INSTALLATION GUIDE PART ONE: Pre-Installation Cleaning Products & Tools Grease and wax remover General Paint-safe Cleaner Isopropyl Alcohol (IPA) Lint-Free Towel or Lint-Free Paper Towel Squeegee
More informationGRANITE COMPOSITE SINK
GRANITE COMPOSITE SINK CONTENTS Sink Installation Faucet Drilling Drop-In Sink Undermount Sink Drain Installation 2 3 4 5 Materal Care and Maintenance 6 1 FAUCET DRILLING The hole for the faucet can be
More informationWhite Speckles on the Garment
GT DIGITAL GARMENT For Technical Assistance Please Call Toll Free 1-877-4BROTHER Email: tsupport@brother.com White Speckles on the Garment White speckles on the garment may appear in three ways: On areas
More informationMixing Training Course P/N Rev. D
THIS DOCUMENT IS. PLEASE REFER TO THE OPERATOR'S MANUAL FOR COMPLETE INSTRUCTIONS. GranuFlo I Version 2 and GranuFlo II w/ Citrasate DRY Update Kit Mixing Training Course P/N 460030 Rev. D 24/10/2017 Introduction
More informationCBT Bowl & wrap replacement
CBT bowl & wrap replacement 2 CBT BOWL & WRAP REPLACEMENT Revision History rev. level 01_03.14.2012 rev. level 02_03.19.2012 rev. level 03_03.23.2012 rev. level 04_05.30.2013 NOTE: due to the fact that
More informationENCAPSULATION CLEANING TECHNOLOGY. An overview of encapsulation chemistry and its applications
ENCAPSULATION CLEANING TECHNOLOGY An overview of encapsulation chemistry and its applications ENCAPSULATION THE CHEMISTRY AND APPLICATIONS FROM THE LABORATORY Encapsulation chemistry is a significant step
More informationXPS-ProDry User s Guide Dryer Base
XPS-ProDry User s Guide XPS-ProDry User s Guide Dryer Base For Use with Inkjet Imaging Systems Manual Part#: M-3120 Revision: August 2005 XPS-ProDry User s Guide Written by Frank Mauri & John Brand Published
More informationMDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX
MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Operation & Maintenance Manual MODELS MDX 800 1000 1200 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY 2 1.0
More informationMDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250
MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap Operation & Maintenance Manual MDX MODELS 18 THRU 250 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY
More information82. Siphon all gas out of the tank. 83. Disconnect the fuel filler and vent tube with a Phillips screwdriver.
Chapter 5 - Gas Tank Removal, Cleaning, Sealing (Video Clip 5) 81. Gas tank removal and cleaning and sealing was completed using the Eastwood Gas Tank Sealer Kit. Other items required included (Purchase
More informationApplication Data Sheet
Application Data Sheet Chemical Cleaning after Thinning, Backside Grinding, Lapping, or Polishing of Silicon or Gallium Nitride Substrates Wafer cleaning after thinning, backside grinding, polishing, or
More informationTHE CITY OF NEW YORK DEPARTMENT OF SANITATION
THE CITY OF NEW YORK DEPARTMENT OF SANITATION NOTICE OF ADOPTION OF FINAL RULES DESIGNATING RIGID PLASTIC ITEMS AS RECYCLABLE MATERIAL FOR COLLECTION BY THE DEPARTMENT NOTICE IS ;HEREBY GIVEN in accordance
More informationCondensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators
Condensate Treatment Solutions CTS Series Eliminator II Oil-Water Separators 2 Condensate Treatment Solutions A Cleaner Environment & Reduced Disposal Costs Compressed air is compressed and discharged
More informationOWNER S MANUAL WISTERIA
OWNER S MANUAL WISTERIA INSTALLATION OPERATION MAINTENANCE BATHTUB REPAIR ONE-PIECE FREESTANDING BATHTUB INSTALLATION alcove.ca Do not discard. Save these instructions for further use. Table of Content
More informationHandheld Training Manual
Handheld Training Manual Date: 10-24-2018 Document Number: 239-128 rev 1 How it Works REVO Systems use short wave infrared light to cure coatings from the inside out. Traditional methods of curing use
More informationSWITCHBOARD. GENERAL CLEANING m PAGE. NOTICE Not for use or disclosure outside the Bell System except under written agreement
BELLSYSTEMPRACTICES AT&TCo Standard SECTION069-379-801 Issue, Dee ber 1981 SWITCHBOARD EQUIPMENT GENERAL CLEANING m ~\fjfufr{ FILE COPY CONTENTS PAGE l. GENERAL........... 1 2. APPARATUS.......... 2 3.
More informationCPAP Washbasin Manual
CPAP Washbasin Manual www.mtts-asia.com CPAP-WB-MAN-01-REV3.02EN Company information MEDICAL TECHNOLOGY TRANSFER AND SERVICES CO., LTD No. 26, Lane 41, An Duong Vuong street, Tay Ho district, Hanoi, Vietnam
More informationO.D / 2" (444) 15 1 / 2 " (393) Maximum I.D / 4 " (336) 1 3 / 4 " (45) 1 1 / 4 " (32)
standard basin 100 Specifications 1.1.3 Standard Round Basin with Overflow Item No. 100 For Undercounter Mount Installation Recommended openings for Under Counter mounting: Min. Diameter: 13 1 / 4 (337).
More informationDesiccants & Driers. By Norm Christopherson
Desiccants & Driers By Norm Christopherson Filter-driers play a pivotal role in the operation of hvac systems. At the heart of the drier is the desiccant held in the drier s cylindrical metal container.
More informationTURBOWASH TM... Pot and Pan Sink
TURBOWASH TM... Pot and Pan Sink MODEL TW ML-110644 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 33800 Rev. A (4-98) Installation, Operation, and Care of TurboWash TM Pot and Pan Sink SAVE THESE INSTRUCTIS
More informationSubject: Air Conditioning Odor (Install Evaporator Core Dryer Kit and Apply Cooling Coil Coating)
of 5 9/26/2011 8:38 PM Subject: Air Conditioning Odor (Install Evaporator Core Dryer Kit and Apply Cooling Coil Coating) Models: 2012 and Prior GM Passenger Cars and Trucks All Equipped with Air Conditioning
More informationREAD AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions
READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION Humidifier De-scaling Solution and Neutralizer Usage Instructions Safety instructions HUMIDIFIER DE-SCALING SOLUTION HUMIDIFIER DE-SCALING NEUTRALIZER
More informationInstallation Manual PS-225 & PS-275
Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationElectric Digital Kettle
Electric Digital Kettle OWNER S MANUAL Model EK119H 120V., 60Hz., 1800 Watts. EURO-PRO Operating LLC Boston, MA, 02465 1 (800) 798-7398 www.euro-pro.com COPYRIGHT 2008 EURO-PRO OPERATING LLC IMPORTANT
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Self-Contained Crescent Cuber Models KM-255BAH KM-255BWH A Superior Degree of Reliability INSTRUCTION MANUAL www.hoshizaki.com Issued: 10-4-2006 IMPORTANT Only qualified service
More informationBathroom furniture installation instructions. Contents. Fitting of wall hung brackets 05. Getting started 02. Plumbing recommendations 05
Bathroom furniture installation instructions Contents Getting started 02 Required tools & materials 02 Vanity installation 02 Hinge adjustment 03 Soft close drawers 04 Fitting of wall hung brackets 05
More informationRobobrew 35L All In One Brewery with Pump Model: 8695
Instruction Sheet Robobrew 35L All In One Brewery with Pump Model: 8695 WARNING IMPORTANT INFORMATION! 1. Please read this ENTIRE instruction sheet before using the Robobrew unit. If you are unsure about
More informationD Dissolution Units Mixing Training Course P/N Rev. C
THIS DOCUMENT IS. PLEASE REFER TO THE OPERATOR'S MANUAL FOR COMPLETE INSTRUCTIONS. D Dissolution Units Mixing Training Course P/N 460027 Rev. C 23/10/2017 "Mixing Training Course" P/N 460027 Rev. C Introduction
More informationUSER MANUAL MINITRACER PORTABLE SNIFFER
USER MANUAL MINITRACER PORTABLE SNIFFER CONTACT US PHONE/FAX Phone: 801.486.1015 Fax: 801.486.1032 ADDRESS FLUIDX Equipment, Inc. 139 W. 2260 S. Salt Lake City, UT 84115 www.fluidxinc.com SMT-07-1006 Rev
More informationPERFORM Operating Document
PERFORM Operating Document Use and Maintenance of Tuttnauer Table-Top Autoclave PC-POD-CA-006-v03 Revision History Version Reason for Revision Date 01 New POD 13-Aug-13 02 POD Section 3.1.3 and 3.2 revised
More informationCARE AND MAINTENANCE OF PRAVOL DURA-SHIELD COMPOSITE DECK BOARDS
AND MAINTENANCE OF PRAVOL DURA-SHIELD COMPOSITE DECK BOARDS Before you start: Using a pressure washer is applicable, with a wide fan tip, but only at pressures under 1,500 psi and at a distance of 12 above
More informationINSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING
January 207 80-572 Rev - 2950 Mechanic Street Lake City, PA 6423 USA Phone: -800-840-9906 Fax: 84-774-0778 Email: info@vanairsystems.com www.vanairsystems.com INSTALLATION, OPERATION & MAINTENANCE MANUAL
More informationLeading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS
Leading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS WATER SAMPLE OIL OUT Condensate Treatment Solutions for a Cleaner Environment and Reduced Disposal Costs The
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUTIONS 20007013160 Important We recommend that this product is installed by a qualified professional plumber who is certified by NVQ (National Vocational Qualification) or SNVQ (Scottish
More informationMurano Shower Cabin Installation Instruction
Murano Shower Cabin Installation Instruction IMPORTANT Please read carefully the following instructions before installing your shower cabin. If you have any questions on this shower cabin installation
More informationOwner s Manual: Care and Maintenance Instructions
Owner s Manual: Care and Maintenance Instructions (rev. 12.20.2011) Congratulations on your purchase of a Pacific Architectural Millwork wood product! With proper care and operation, your window or door
More informationFor routine maintenance of polished granite installations with a cleaner and protector:
NOTE: For all recommended products: read the entire product label before using. Use only as directed. Always test in a small inconspicuous area with a 24-hour cure time to determine ease of application
More informationFreestyle 2000 Cleaning
CCFS 2000 Cleaning Process Rev 1-2-0-7-20160520 COCA-COLA FREESTYLE Freestyle 2000 Cleaning Copyright 2015, The Coca-Cola Company Classified - No Category CCFS 2000 Cleaning Process Rev 1-2-0-7-20160520
More informationEcoVision Door Manual
EcoVision Door Manual for Reach-In (RMTD) Merchandisers Installation & Operation Manual Shipped With Case Data Sheets IMPORTANT Keep in store for future reference! MANUAL- I/O ECOVISION REACH-IN DOORS
More informationowner s manual produitsneptune.com Do not discard. Save these instructions for further use.
owner s manual AMAZE Installation OPERATION MAINTENANCE Bathtub REPAIR ONE-PIECE freestanding Bathtub INSTALLATION produitsneptune.com Do not discard. Save these instructions for further use. Table of
More informationREF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.
4.4 SUPPLY PUMPAK ASSEMBLY NOTE: This section applies only to systems, which include a supply pumpak. Only the H6, XA, and XC series systems contain a supply pumpak. If your system is a single zone, H6
More informationSafety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions
Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No. 106-4842 Form No. 3353-529 Rev B Installation Instructions Note: Determine the left and right sides of the machine from the normal operating
More informationFIREPLACE INSTALLATION
CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace
More information1/7 INSTALLATION INSTRUCTIONS. Rough Installation
Rev 06/2016 Installation Instruction 3/4 Thermostatic Control Please read the instructions completely before beginning the installation. 3/4" Thermostatic control Model Number: 7093..-TM INSTALLATION INSTRUCTIONS
More informationStandard Operating Procedure for Oil & Grease Method EPA1664A
Standard Operating Procedure for Oil & Grease Method EPA1664A This document is intended to enable a technician new to Solid Phase Extraction (SPE) technology to perform SPE on oil and grease samples while
More informationPRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required
PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES Read and follow all steps and guides carefully before installing and using your reverse osmosis system. Do not use
More informationMODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL
MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL 19 Brigham Street Unit #8 Marlborough, MA USA 01752 Tel: (508) 263-5900 (800) 276-3729 Fax: (508) 486-9348 E-mail: h2o@edgetech.com www.edgetech.com
More informationAPARTMENT MAINTENANCE SERIES
ORPORATION CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS AM-4 APARTMENT MAINTENANCE SERIES TOP-MOUNT REFRIGERATOR/FREEZERS OLD DESIGN 14 cu. ft. MULLION EVAPORATOR DESIGN 12 cu. ft. NEW DESIGN 14
More informationSELF-CONTAINED CRESCENT CUBER
Reliability is a beautiful thing TM SELF-CONTAINED CRESCENT CUBER KM-250BAF KM-250BWF INSTRUCTION MANUAL ISSUED: March 14, 2000 REVISED: December 22, 2004 IMPORTANT Only qualified service technicians should
More informationDEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.
General Description The DPH-2020 is a two stage dew point hygrometer using the chilled mirror principle to determine the absolute humidity of a gas in terms of its dew- or frost-point temperature. It was
More informationInstallation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers
OM010 Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers The operating and maintenance instructions contained within this package are for ThermaFlex gasketed
More informationThickness (mm) 8113MG.1/NS 10 x Sonic Silver cm x 0.5 cm non-perforated. 8113GO.1/NS 10 x Gold cm x 0.5 cm non-perforated
INSTRUCTIONS FOR USE ORFIT STRIPS A. GENERAL PRODUCT INFORMATION ORFIT STRIPS are cut from a low temperature thermoplastic sheet of coated material. The strips are designed for the quick and easy production
More informationElectron Microscopy Sciences
Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 62420-Series Bacti-Cinerator IV Inoculating Loop and Needle Sterilizer P.O. Box 550 s1560 Industry Road s Hatfield PA 19440 1 Introduction The BACTI-CINERATOR
More informationCONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction
TROUBLE-SHOOTING CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction Problem After installation shower only runs HOT or COLD and will not mix. Solution Hot & Cold supplies are
More informationApplication note. LCD Module. Precautions for LCM handling. LCM handling V 1.1
LCD Module Precautions for LCM handling Application note LCM handling V 1.1 admatec GmbH Wendenstrasse 29, 20097 Hamburg, Germany Tel.: +49-40-238533-0, Fax: +49-40-238533-11 Internet: www.admatec.de,
More information