Gas heaters and convectors ROBUR
|
|
- Kimberly Carson
- 6 years ago
- Views:
Transcription
1 Gas heaters and convectors ROBUR
2 Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7 Robur M connection diagrams...8 Robur Mxt general characteristic...9 Robur Mxt dimensions...9 Robur Mxt construction...10 Robur Mxt technical data...11 Robur Mxt installation...12 Robur Mxt connection diagrams...12 Robur G general characteristic...13 Robur G dimensions...13 Robur G construction...14 Robur G technical data...15 Robur G installation...16 Robur G connection diagrams...16 Robur F general characteristic...17 Robur F1 dimensions...17 Robur F1 construction...18 Robur F1 technical data...19 Robur F1 installation...20 Robur F1 accessories...21 Robur F1 connection diagrams...22 Robur B15 general characteristic...23 Robur B15 dimensions...23 Robur B15 construction...24 Robur B15 technical data...25 Robur B15 installation...26 Robur B15 connection diagrams...26 Calorio M general characteristic...27 Calorio M dimensions...27 Calorio M construction...27 Calorio M technical data...28 Calorio M installation...28 Elements of control systems...29 Chimney packages...30 Examples of chimney packages installation...32 Selection of chimney packages...34 Selection of ventilation air inlet
3 General characteristic ROBUR M ROBUR M Thermal load [kw] 20,6 72,5 Heating capacity [kw] 18,3 63,8 Air flow [m 3 /h] Weight [kg] Casing powder-painted sheet steel Colour orange (PANTONE 151C) or grey (RAL 7035) ROBUR MC The M series gas heaters with atmospheric burner are suitable for heating medium and big cubature buildings like: industrial halls, sports halls, warehouses, sacral buildings, showrooms. Heaters are equipped with: switch with failure signalling and alarm reset. There are two types of units available: ROBUR M Heater with axial fan designed for indoor installation. ROBUR MC Heater with radial fan, designed for operation with air duct installation; use with mixing chamber enables two functions: heating and ventilation. Designed for indoor installation. Dimensions E E A A I I ROBUR M ROBUR MC B C F G B F D H C G K (1) K (1) D H J J J (1) E (1) Type of connection with chimney: flat flange without gasket Dimensions [mm] ROBUR M A B C D E F G H I J K M M M M M M M Dimensions [mm] ROBUR MC A B C D E F G H I H I M 20C M 30C M 60C
4 Construction HEAT EXCHANGER Heat exchanger is made of aluminium, which means greater conductivity compared with common steel solutions. Double ribbing and unique design create a floor effect, i.e. smaller temperature stratification in the heated room. No welded connections and special clamps used when assembling the exchanger with the combustion chamber guarantee full tightness and high reliability. FAN Axial fan in ROBUR M heater produces flow of warm air into the room. Radial fan in ROBUR MC heater enables operation with mixing chamber, which ensures two functions - heating and ventilation. ATMOSPHERIC BURNER MADE OF STAINLESS STEEL Simple construction made of stainless steel and no welded connections exclude changes in material structure and increase reliability of the element. WIDE RANGE OF UNITS Wide range of units (10 models) makes it possible to precisely match the heating capacity and type of unit to customer needs. 4
5 Technical data Gas type ROBUR M 20 ROBUR M 25 ROBUR M 30 ROBUR M 35 natural gas LPG Nominal thermal load [kw] 20,6 28,8 34,8 42,2 48,2 57,3 72,5 Nominal heating capacity [kw] 18,3 25,5 30,7 37,4 42,5 50,7 63,8 Nominal gas consumption (max.) (1) G 27 [m 3 /h] 2,49 3,48 4,20 5,10 5,82 6,92 8,76 G 20 [m3 /h] 2,18 3,04 3,68 4,46 5,10 6,06 7,67 ROBUR M 40 ROBUR M 50 ROBUR M 60 G 30 / G 31 [kg/h] 1,62 2,27 2,74 3,32 3,80 4,52 5,72 Efficiency [%] 88,8 88,5 88,2 88,6 88,2 88,5 88,0 Gas supply pressure G 20 / G 27 [mbar] 20 G 30 [mbar] 30 G 31 [mbar] 37 Gas connection [ ] ½ ½ ½ ½ ½ ¾ ¾ Diameter of air/exhaust duct (2) [mm] 130/110 Power supply [V/Hz] 230/50 Power consumption [W] Nominal air flow (3) [m 3 /h] Temperature rise (1) [K] ,3 32,6 33, ,5 Noise level at the distance of 6 m open space [db(a)] typical installation [db(a)] Range of air stream (4) Recommended height of installation for on-wall units [m] 2,5 2,5/3 2,5/3 2,5/3 2,5/3 2,5/3 3/3,5 Operating temperature range (5) [ o C] 0 35 Weight [kg] Gas type (1) At 15 o C mbar (2) Nominal diameter of rigid exhaust duct entering in the specific cylindrical housing (3) At 20 o C mbar (4) Values measured in the open space In actual installations the stream of warm air can have a greater range than mentioned above; This value depends on installation height, installation place and thermal insulation of heated area (5) Air temperature in place of installation of the unit ROBUR M 20C ROBUR M 30C ROBUR M 60C natural gas LPG Nominal thermal load [kw] 20,6 34,8 72,5 Nominal heating capacity [kw] 18,3 30,7 63,8 Nominal gas consumption (max.) (1) G 20 [m 3 /h] 2,18 3,68 7,67 G 27 [m 3 /h] 2,49 4,20 8,76 G 30 / G 31 [kg/h] 1,62 2,72 5,72 Efficiency [%] 88,8 88,2 88,0 Gas supply pressure G 20 / G 27 [mbar] 20 G 30 [mbar] 30 G 31 [mbar] 37 Gas connection [ ] ½ ½ ¾ Diameter of air/exhaust duct (2) [mm] 130/110 Power supply [V/Hz] 230/50 Power consumption [W] Air flow (3) at max. permissible pressure drop [m 3 /h] with free outlet [m 3 /h] Temperature rise (1) [K] Static pressure [Pa] 110 Operating temperature range (5) [ o C] 0 35 Weight [kg]
6 Installation Installation console and brackets Installation brackets Enable installation of the unit perpendicularly to the wall (installation under the ceiling is not allowed) Lower rotary console Enables installation of the unit on the wall and horizontal regulation of the angle in relation to the wall. Installation brackets Enable installation of the ROBUR MC with mixing chamber perpendicularly to the wall (installation under the ceiling is not allowed). Installation options Recommended installation distances for ROBUR M 0,5 m 2,5 3,5 m 0,4 m 0,35 m 6
7 Installation options Recommended installation distances for ROBUR MC 2,5 3,5 m 0,4 m Accessories Mixing chamber A Dedicated for MC type gas heaters with radial fan. ROBUR MC gas heaters with ROBUR KM mixing chamber form a heating and ventilation unit. It is the easiest way to create an efficient mechanical ventilation without additional systems. B B D c E Dimensions [mm] A B C D E KM ROBUR M 20 C KM ROBUR M 30 C KM ROBUR M 60 C
8 Connection diagrams Electrical connection for ROBUR MC with mixing chamber 3 1,5 mm 2 control board (1) NPCT-10 LM24 LM24 3 1,5 mm 2 2 1,5 mm 2 3 0,5 mm 2 3 1,5 mm 2 3 0,5 mm 2 3 0,5 mm 2 3 0,5 mm 2 Power supply ~ 230V RA reset Power supply ~ 230V (1) Control board: ROBUR KM control board with dampers actuators and controller enable to set the dampers opening angle; ROBUR KM + WD control board with dampers actuators and controller enable to set the dampers opening angle; Additional possibility of connection of roof fan with inverter enables to maintain air balance in the building Electrical connection for ROBUR M 6 1,5 mm 2 RE or 2 1,5 mm 2 3 0,5 mm 2 RA reset + summer/winter or reset 3 1,5 mm 2 Power supply ~230 V 8
9 General characteristic ROBUR Mxt ROBUR Mxt Thermal load [kw] 48,2 72,5 Heating capacity [kw] 42,5 63,8 Air flow [m 3 /h] Weight [kg] Casing powder-painted sheet steel Colour grey (RAL 7035) The Mxt series gas heaters are designed for outdoor installation and are suitable for heating medium and big cubature buildings like: industrial halls, sports halls, warehouses, sacral buldings, showrooms. ROBUR Mxt is a heater with axial fan with increased static pressure and amospheric burner made of stainless steel. It enables installation of air ducts and mixing chamber, so the unit can perform two functions: heating and ventilation. Heaters are equipped with: summer/winter switch with integrated signalling and alarm reset and basic chimney package. Dimensions ROBUR Mxt B I A E J K L M S R F D G O C H N P Dimensions [mm] ROBUR Mxt A B C D E F G H I J K L M N O P R S M 40xt M 50xt M 60xt
10 Construction AIR FLOW REGULATION Regulation of warm air flow supplied into the room depending on inlet air temperature. It enables the supply of warm, fresh air even at extremely low outdoor temperatures, i.e. -40 o C. OUTDOOR INSTALLATION Outdoor installation of the unit enables full or partial supply of the fresh air and additional space in the room. BURNER MADE OF STAINLESS STEEL Simple construction made of stainless steel and no welding connections exclude changes in material structure and increase reliability of the element. AXIAL FAN Axial fan with increased static pressure allows the use of duct installation or mixing chamber, so the heater can perform two functions - heating and ventilation. 10
11 Technical data Gas type (1) At 15 o C mbar (2) Nominal diameter of rigid exhaust duct entering in the specific cylindrical housing (3) At 20 o C mbar (4) With winter package unit can operate in temperatures from -40 o C. ROBUR M 40xt ROBUR M 50xt ROBUR M 60xt natural gas LPG Nominal thermal load [kw] 48,20 57,30 72,50 Nominal heating capacity [kw] 42,50 50,70 63,80 Nominal gas consumption G 20 [m 3 /h] 5,10 6,06 7,67 (max.) (1) G 30 / G 31 [kg/h] 3,80 4,52 5,72 Efficiency [%] 88,2 88,5 88 Gas supply pressure G 20 [mbar] 20 G 30 [mbar] 30 G 31 [mbar] 37 Gas connection [ ] ½ ¾ ¾ Diameter of air/exhaust duct (2) [mm] 130/110 Moisture protection class [IP] X4B 2 Power supply [V/Hz] 230/50 Power consumption [W] Air flow (3) at max. permissible pressure drop [m 3 /h] max. with free outlet [m3 /h] reduced with free outlet [m 3 /h] Max. Static pressure [Pa] Max. permissible underpressure [Pa] Temperature rise (1) [K] 28,4 27,3 23 Temperature rise at max. permissible pressure drop (1) [K] 46, ,4 Operating temperature range (4) [ o C] Weight [kg]
12 Installation Installation brackets Installation brackets Enable installation of the unit perpendicularly to the wall (installation under the ceiling is not allowed). Installation options 2 2,5 m 1 m (1) (1) Recommended installation distance from openings in the wall Connection diagram Electrical connection for ROBUR Mxt 2 1,5 mm 2 6 1,5 mm 2 3 1,5 mm 2 RE or RA reset + summer/winter Power supply ~230 V 12
13 General characteristic Robur G ROBUR G Thermal load [kw] Heating capacity [kw] 15,8 90,2 Air flow [m 3 /h] Weight [kg] Casing powder-painted sheet steel Colour orange (PANTONE 151C) or grey (RAL 7035) The G series condensing, modulated gas heaters are designed for indoor installation. They are suitable for buildings like: workshops, factories, commercial buildings, exhibition halls, sports halls and fitness centres. Heaters are equipped with thermostat with programmer and signalling of operating status of the unit. Dimensions ROBUR G J (1) K (1) J (1) K (1) F A E G B H D C I D (1) Type of connection with chimney: flange with seal Dimensions [mm] ROBUR G A B C D E F G H I J K G G G G
14 Construction HEAT EXCHANGER Heat exchanger is made of aluminium, which means greater conductivity compared with common steel solutions. Double ribbing and unique design create a floor effect, i.e. smaller temperature stratification in the heated room. CLOSED COMBUSTION CHAMBER Construction made of stainless steel, no welded connections and special clamps used when assembling the exchanger with the combustion chamber guarantee full tightness and high reliability. MODULATED BURNER Construction made of stainless steel and no welded connections exclude changes in material structure. Modulation of burner power and condensing technology allow to achieve high efficiency even up to 105,7% and to reduce NOx particles emission. MODULATED FAN Modulated, axial fan ensure warm air flow into the room and automatic regulation of unit s heating capacity. 14
15 Technical data Gas type ROBUR G 30 ROBUR G 45 ROBUR G 60 ROBUR G 100 natural gas LPG Nominal thermal load [kw] Minimum thermal load [kw] ,3 31,7 Nominal heating capacity [kw] 29,2 43,3 56,2 90,2 Minimum heating capacity [kw] 15,8 15,6 20,2 33,5 Nominal gas consumption G 20 [m 3 /h] 3,17 4,76 6,14 9,84 (max.) (1) G 30 / G 31 [kg/h] 2,33 3,5 4,5 7,22 Minimum gas consumption G 20 [m 3 /h] 1,58 1,58 2,14 3,35 (max.) (1) G 30 / G 31 [kg/h] 1,16 1,16 1,5 2,46 Efficiency at minimum thermal load [%] 105,3 104,3 104,6 105,7 Efficiency at maximum thermal load [%] 97,3 96, Gas supply pressure G 20 [mbar] 20 G 30 [mbar] 30 G 31 [mbar] 37 Gas connection [ ] 3/4 Diameter of air/exhaust duct (2) [mm] 80/80 Power supply [V/Hz] 230/50 Power consumption [W] Temperature rise at maximum speed (1) [K] 31,8 31,8 30,8 32,1 Temperature rise at minimum speed (1) [K] 16,1 19,6 17,9 18,9 Air flow (3) nominal [m 3 /h] reduced [m 3 /h] Noise level at the distance of 6 m open space [db(a)] typical installation [db(a)] ,5 65,5 Range of air stream (4) Recommended height of installation [m] 2,5/3 2,5/3 3/3,5 3/4 Operating temperature range (5) [ o C] 0 35 Weight [kg] (1) At 15*C mbar (2) Nominal diameter of rigid exhaust duct entering in the specific cylindrical housing (3) At 20*C mbar (4) Values measured in the open space In actual installations the stream of warm air can have a greater range than mentioned above This value depends on installation height, installation place and thermal insulation of heated area (5) Air temperature in place of installation of the unit 15
16 Installation Installation console and brackets Installation brackets Enable installation of the unit perpendicularly to the wall (installation under the ceiling is not allowed) Lower rotary console Enables installation of the unit on the wall and horizontal regulation of the angle in relation to the wall. Installation options Recommended installation distances for 0,5 m 0,5 m 2,5 4 m 0,4 m 0,3 m Connection diagram Electrical connection for ROBUR G 2 0,5 mm 2 3 1,5 mm 2 chronothermostat Power supply ~230 V 16
17 ROBUR F1 ROBUR F1 C D I I General characteristic Robur F ROBUR F1 F1 C Thermal load [kw] 23,08 48,35 Heating capacity [kw] Air flow [m 3 /h] Weight [kg] Casing powder-painted sheet steel Colour orange (PANTONE 151C) or grey (RAL 7035) ROBUR F1 version for installation under the ceiling (V) Gas heater with blow burner designed for indoor installation. The F series heaters are suitable for heating of various buildings: warehouses, supermarkets, industrial buildings and workshops.. There are two types of units available: Heater is available in version for installation on the wall, under the ceiling and with axial or radial fan. Heaters are equipped with: summer/winter switch with integrated signalling and reset of alarms. ROBUR F1 Gas heater with burner made of stainless steel. Axial fan ensures warm air flow into the room. F1 H version is designed for installation on the wall. F1 V version is designed for installation under the ceiling. ROBUR F1 C ROBUR F1 C Gas heater with burner made of stainless steel. Radial fan enables operation with duct installation or mixing chamber. F1 C H version is designed for installation on the wall. F1 C V version is designed for installation under the ceiling. Dimensions J (1) K (1) E D E A F A F B G B G C H C H (1) Type of connection with chimney: flange with seal Dimensions [mm] ROBUR F1 A B C D E F G H I J K F F F F Dimensions [mm] ROBUR F1 C A B C D E F G H I J K F1 21 C F1 41 C F1 51 C
18 Construction HEAT EXCHANGER Heat exchanger is made of aluminium, which means greater conductivity compared with common steel solutions. Double ribbing and unique design create a floor effect, i.e. smaller temperature stratification in the heated room. CLOSED COMBUSTION CHAMBER Construction made of stainless steel, no welded connections and special clamps used when assembling the exchanger with the combustion chamber guarantee full tightness and high reliability. BURNER Construction made of stainless steel and clenched edges exclude changes in material structure. Use of fan with gas mixer next to the burner helps in achieving optimal gas and air mixture, which reduces NOx particles emission. FAN Axial fan in ROBUR M heater produces flow of warm air into the room. Radial fan in ROBUR MC heater enables operation with mixing chamber, which ensures two functions - heating and ventilation. 18
19 Technical data Gas type F1 21 F1 31 F1 41 F1 51 F1 21 C F1 41 C F1 51 C natural gas LPG Nominal thermal load [kw] 23,08 30,77 37,15 48,35 23,08 37,15 48,35 Nominal heating capacity [kw] 21,0 28,0 33,8 44,0 21,0 33,8 44,0 Nominal gas consumption G 20 [m 3 /h] 2,43 3,25 3,93 5,11 2,43 3,93 5,12 (max.) (1) G 30 / G 31 [kg/h] 1,78 2,38 2,87 3,74 1,78 2,87 3,74 Efficiency [%] 91 Gas supply pressure Gas connection [ ] G 20 [mbar] 20 G 30 [mbar] 30 G 31 [mbar] 37 Diameter of air/exhaust duct (2) [mm] 80/80 Power supply [V/Hz] 230/50 Power consumption [W] Temperature rise (1) [K] 31,1 30,7 29, ,2 27,9 27,6 Air flow (3) at max. permissible pressure drop [m 3 /h] with free outlet [m 3 /h] Noise level at the distance open space [db(a)] of 6 m typical installation [db(a)] Range of air stream for on-wall units (4) [m] Recommended height of installation for on-wall units [m] 2,5/3 2,5/3 2,5/3 3/3,5 Recommended height of installation for units installed under the ceiling [m] 3/4 3,5/4,5 4/6 3/3,5 Static pressure [Pa] Operating temperature range (5) [ o C] 0 35 Weight [kg] (1) At 15 o C mbar (2) Nominal diameter of rigid exhaust duct entering in the specific cylindrical housing (3) At 20 o C mbar (4) Values measured in the open space In actual installations the stream of warm air can have a greater range than mentioned above This value depends on installation height, installation place and thermal insulation of heated area (5) Air temperature in place of installation of the unit ¾ 19
20 Installation Installation console and brackets Installation brackets Enable installation of the unit perpendicularly to the wall (installation under the ceiling using this brackets is not allowed) Lower rotary console Enables installation of the unit on the wall and horizontal regulation of the angle in relation to the wall. Installation brackets Enable installation of the ROBUR F1 C or ROBUR F1 C with mixing chamber perpendicularly to the wall (installation under the ceiling using this brackets is not allowed). Installation options Recommended installation distances for ROBUR F1 0,2 m 0,5 m 3 m 2,5 3,5 m 0,4 m 0,35 m 20
21 Installation options Recommended installation distances for ROBUR F1 C 2,5 3,5 m 0,4 m 3 m Accessories Mixing chamber A Dedicated for F1 C type gas heaters with radial fan. ROBUR F1 C gas heaters with ROBUR KM mixing chamber form a heating and ventilation unit. It is the easiest way to create an efficient mechanical ventilation without additional systems. B B D c E Dimensions [mm] A B C D E KM ROBUR F1 21 C KM ROBUR F1 41 C KM ROBUR F1 51 C
22 Connection diagrams Electrical connection for ROBUR F1 C with mixing chamber 3 1,5 mm 2 control board (1) NPCT-10 LM24 LM24 3 1,5 mm 2 2 1,5 mm 2 3 0,5 mm 2 3 1,5 mm 2 3 0,5 mm 2 3 0,5 mm 2 3 0,5 mm 2 Power supply ~ 230V RA reset Power supply ~ 230V (1) Control board: ROBUR KM control board with dampers actuators and controller enable to set the dampers opening angle; ROBUR KM + WD control board with dampers actuators and controller enable to set the dampers opening angle; Additional possibility of connection of roof fan with inverter enables to maintain air balance in the building Electrical connection for ROBUR F1 2 1,5 mm 2 6 1,5 mm 2 3 1,5 mm 2 RE or RA reset + summer/winter Power supply ~230 V 22
23 General characteristic Robur B 15 ROBUR B 15 Thermal load [kw] 15 Heating capacity [kw] 13,8 Air flow [m 3 /h] 2170 Weight [kg] 28 Casing powder-painted sheet steel Colour orange (PANTONE 151C) or grey (RAL 7035) Gas heater with blow burner powered by G20 natural gas, equipped with closed combustion chamber. Designed for indoor installation. ROBUR B 15 heater is suitable for heating of small and medium cubature buildings like: stores, exhibition halls, laboratories or sacral buildings. Heaters are equipped with: summer/winter switch with integrated signalling and alarm reset. Dimensions ROBUR B 15 A I J (1) K (1) B F C D H G E (1) Type of connection with chimney: flange with seal Dimensions [mm] A B C D E F G H I J K ROBUR B
24 Construction AXIAL FAN Axial fan ensures flow of warm air into the room. CLOSED COMBUSTION CHAMBER Construction made of stainless steel, no welded connections and special clamps used when assembling the exchanger with the combustion chamber guarantee full tightness and high reliability. BLOW BURNER WITH FAN Construction made of stainless steel and clenched edges exclude changes in material structure. Use of fan with gas mixer next to the burner helps in achieving optimal gas and air mixture, which reduces NOx particles emission. EASY INSTALLATION Unit is characterized by low weight, compact dimensions and various options of installation (on the wall, under the ceiling or at the angle to the wall). 24
25 Technical data Gas type B 15 natural gas Nominal thermal load [kw] 15 Nominal heating capacity (max.) [kw] 13,8 Nominal gas consumption (max.) (1) G 20 [m 3 /h] 1,58 Efficiency [%] 92 Gas supply pressure G 20 [mbar] 20 Gas connection [ ] Diameter of air/exhaust duct (2) [mm] 80/80 Power supply [V/Hz] 230/50 Power consumption [W] 160 Temperature rise (1) [K] 21 Air flow (3) with free outlet [m 3 /h] 2170 Noise level at the distance of 6 m open space [db(a)] 40 typical installation [db(a)] 52 Range of air stream (4) for on-wall units [m] 12 Recommended height of installation for on-wall units [m] 2,2/3,0 Operating temperature range (5) [ o C] 0 35 Weight [kg] 30 (1) At 15 o C mbar (2) Nominal diameter of rigid exhaust duct entering in the specific cylindrical housing (3) At 20 o C mbar (4) Values measured in the open space In actual installations the stream of warm air can have a greater range than mentioned above This value depends on installation height, installation place and thermal insulation of heated area (5) Air temperature in place of installation of the unit ¾ 25
26 Installation Installation console and brackets Rotary console Enables installation of the unit on the wall and horizontal regulation of the angle in relation to the wall. Installation options Recommended installation distances for 2,2 3,0 m 0,4 m 0,5 m Connection diagram Electrical connection for ROBUR B ,5 mm 2 6 1,5 mm 2 3 1,5 mm 2 RE or RA reset + summer/winter Power supply ~230 V 26
27 General characteristic CALORIO M CALORIO M Thermal load [kw] 2,51 5,23 Heating capacity [kw] 2,26 4,71 Weight [kg] Casing powder-painted sheet steel Colour white (RAL 9003) Suitable for small cubature buildings, i.e. offices, stores, day rooms, summer houses, workshops, sacral facilities etc. Available in 2 versions of heating capacity from 2,26 to 4,71 kw, each version with automatically modulated burner. Units are equipped with: concentric chimney package with lenght of 0,5 m, bracket, elevation cap. Dimensions CALORIO M Construction BUILT-IN THERMOSTAT Unit is equipped with built-in thermostat with weekly programmer, which ensures easy use and control of the heater. CLOSED COMBUSTION CHAMBER Completely closed combustion chamber guarantees full safety of use. AUTOMATICALLY MODULATED BURNER Automatically modulated burner enable better adjustment of heating capacity to the needs of the heated room. EASY TO USE Convector ensure fast heating of the room without indirect media. Unit is easy to use as well as easy and quick to install. 27
28 Technical data Gas type CALORIO 42 M natural gas LPG CALORIO 52 M Nominal thermal load [kw] 3,62 5,23 Minimum thermal load [kw] 2,51 3,60 Nominal heating capacity [kw] 3,26 4,71 Minimum heating capacity [kw] 2,26 3,18 Nominal gas consumption (max.) Minimum gas consumption (max.) G 20 [m 3 /h] 0,383 0,553 G 30 / G 31 [kg/h] 0,285 0,412 G 20 [m 3 /h] 0,266 0,381 G 30 / G 31 [kg/h] 0,198 0,284 Efficiency [%] Gas supply pressure G 20 [mbar] 20 G 30 [mbar] 30 G 31 [mbar] 37 Diameter of air/exhaust duct [mm] 49/35 Power supply [V/Hz] 230/50 Power consumption [W] Max. acoustic pressure level at the distance of 6 for typical installation [db(a)] Weight [kg] Installation Installation options Recommended installation distances for 10 cm 10 cm 8 cm 28
29 Elements of control systems Category Symbol Picture Description Series of units Switches Summer/winter switch With engaged heating the system turns on the main fan forcing the air flow. Reset button signals malfunction and enables the user to reset heater alarms. F1, F1 C, M, MC, Mxt, B15 Thermostats RA room thermostat Turns on the unit in case of temperature drop below value set by the user and turns o when it is reached. It should be installed in such a place, where it will not be subjected to the in uence of factors that could interfere with the measurement (eg. sunlight). F1, F1 C, M, MC, Mxt, B15 RE programmable room thermostat Maintains temperature in the room on a desired level. Enables the user to program temperature hour-by-hour for every day of the week. F1, F1 C, M, MC, Mxt, B15 Controller Electronic control panel with integrated thermostat enables complete control. FEATURES: Electronic control panel (standard equipment) operation in three modes during the winter (automatic, manual, protection), diagnosis of operation and malfunctions with signalling and alarms, weekly programmer. G 29
30 Chimney packages Picture Package description Package symbol Diameter of ducts Series of units Chimney package for G, F1, F1 C, B15 series units with operation depending on the room horizontal wall crossing. The package consist of: pipe with Ø80 mm diameter and 1000 mm length with horizontal ending fumes discharge. KA Ø80 G, F1, F1 C, B15 Chimney package for M series units with operation depending on the room horizontal wall crossing. The package consist of: pipe with Ø110 mm diameter and 1000 mm length with horizontal ending fumes discharge. MA Ø110 M, MC Chimney package for G, F1, F1 C, B15 series units with operation not depending on the room horizontal wall crossing. The package consist of: pipe with Ø80 mm diameter and 1000 mm length with horizontal ending fumes discharge and pipe with Ø80 mm diameter and 1000 mm length with horizontal ending air supply. KB Ø80 i Ø80 G, F1, F1 C, B15 Chimney package for M series units with operation not depending on the room horizontal wall crossing. The package consist of: pipe with Ø110 mm diameter and 1000 mm length with horizontal ending fumes discharge and pipe with Ø130 mm diameter and 1000 mm length with horizontal ending air supply. MB Ø110 i Ø130 M, MC Chimney package for G, F1, F1 C, B15 series units with operation not depending on the room vertical ceiling crossing. The package consists of: pipe with Ø80 mm diameter and 1000 mm length with vertical ending fumes discharge, 87 joint and pan with condensate drain. KC Ø80 G, F1, F1 C, B15 Chimney package for M series units with operation not depending on the room vertical ceiling crossing. The package consists of: pipe with Ø110 mm diameter and 1000 mm length with vertical ending fumes discharge, 87 joint, pan with condensate drain and pipe with Ø130 mm diameter and 1000 mm length with vertical ending, 90 bend air supply. MC (MCP + MCS) Ø110 i Ø130 M, MC Chimney package for G, F1, F1 C, B15 series units with operation not depending on the room with vertical roof crossing for fumes discharging part and horizontal wall crossing for air supplying part. The package consists of: pipe with Ø80 mm diameter and 1000 mm length with vertical ending fumes discharge, 87 joint, pan with condensate drain and pipe with Ø80 mm diameter and 1000 mm length with horizontal ending air supply. KD Ø80 i Ø80 G, F1, F1 C, B15 Chimney package for M series units with operation not depending on the room with vertical roof crossing for fumes discharging part and horizontal wall crossing for air supplying part. The package consists of: pipe with Ø110 mm diameter and 1000 mm length with vertical ending fumes discharge, 87 joint, pan with condensate drain and pipe with Ø130 mm diameter and 1000 mm length with horizontal ending air supply. MD Ø110 i Ø130 M, MC 30
31 Chimney packages Chimney package for G, F1, F1 C, B15 series units with operation not depending on the room concentric system with Ø125/80 mm diameter with horizontal wall crossing. The package consist of: concentric joint with 90 bend and 500 mm length concentric horizontal ending. KE 1 Ø125 / Ø80 G, F1, F1 C, B15 Chimney package for G, F1, F1 C, B15 series units with operation not depending on the room concentric system with Ø150/100 mm diameter with horizontal wall crossing. The package consist of: concentric joint with 90 bend and and 500 mm length concentric horizontal ending. KE 2 Ø150 / Ø100 G, F1, F1 C, B15 Chimney package for G, F1, F1 C, B15 series units with operation not depending on the room concentric system with Ø125/80 mm diameter with vertical roof crossing. The package consist of: pan with condensate drain, 87 joint fumes discharge and concentric joint with 90 bend, concentric pipe with horizontal ending and 500 mm length and 90 bend air supply. KF 1 Ø125 / Ø80 G, F1, F1 C, B15 Chimney package with increased diameter for G, F1, F1 C, B15 series units with operation not depending on the room concentric system with Ø150/100 mm diameter with vertical roof crossing. The package consist of: pan with condensate drain, 87 joint fumes discharge and concentric joint with 90 bend, concentric pipe with vertical ending and 500 mm length and 90 bend air supply. KF 2 Ø150 / Ø100 G, F1, F1 C, B15 Chimney package for F series units designed for installation under the ceiling and operation no depending on the room concentric system with Ø200/130 diameter with vertical roof crossing. The package consists of: vertical condensate separator, 250 mm and 500 mm pipes air supply, 250 mm and 500 mm pipes fumes discharge, concentric joint and 500 mm concentric pipe with vertical ending. FV Ø200 / Ø130 F1, F1 C Chimney package for units from M20 to M35 with operation not depending on the room concentric system with Ø150/100 mm diameter with horizontal wall crossing. The package consist of: concentric joint with 90 bend and a 500 mm concentric horizontal ending. ME1 Ø150 / Ø100 M, MC Chimney package for units from M40 to M60 with operation not depending on the room concentric system with Ø200/130 mm diameter with horizontal wall crossing. The package consist of: concentric joint with 90 bend and and 500 mm concentric horizontal ending. ME2 Ø200 / Ø130 M, MC Chimney package for units from M20 to M35 with operation not depending on the room concentric system with Ø150/100 mm diameter with vertical roof crossing. The package consist of: pan with condensate drain, 87 joint fumes discharge and concentric joint with 90 bend, concentric pipe with horizontal ending and 500 mm length and 90 bend air supply. MF1 Ø150 / Ø100 M, MC Chimney package for units from M40 to M60 with operation not depending on the room concentric system with Ø200/130 mm diameter with vertical roof crossing. The package consist of: pan with condensate drain, 87 joint fumes discharge and concentric joint with 90 bend, concentric pipe with vertical ending and 500 mm length and 90 bend air supply. MF2 Ø200 / Ø130 M, MC 31
32 Examples of chimney packages installation with ROBUR gas heaters M, MC SERIES Package MA Installation type B22, open system, combustion air collected from the room, exhaust duct conducted through the wall. Package MB Installation type C12, closed system, with separate inlet of combustion air and outlet of exhaust gases. Ducts conducted through the wall. Package MCS + MCP Installation type C32, closed system, with separate inlet of combustion air and outlet of exhaust gases. Ducts conducted through the roof. Package MD Installation type C52, closed system, with separate inlet of combustion air conducted through the wall and outlet of exhaust gases conducted through the roof. Package ME1 / ME2 Installation type C12, closed system, with concentric air/exhaust duct conducted through the wall. Package MF1 / MF2 Installation type C32, closed system, with concentric air/exhaust duct conducted through the roof. 32
33 Examples of chimney packages installation with ROBUR gas heaters G, F1, F1 C, B15 SERIES Package KA Package KB Package KC Installation type B23, open system, combustion air collected from the room, exhaust duct conducted through the wall. Installation type C13, closed system, with separate inlet of combustion air and outlet of exhaust gases. Ducts conducted through the wall. Installation type B23, open system, combustion air collected from the room, exhaust duct conducted through the roof. Package KD Package KE1 / KE2 Package KF1 / KF2 Installation type C53, closed system, with Installation type C13, closed system, with concentric Installation type C33, closed system, with con- separate inlet of combustion air conducted air/exhaust duct conducted through centric air/exhaust duct conducted through through the wall and outlet of exhaust gases the wall. the roof. conducted through the roof. 33
34 Selection of chimney packages M, MC SERIES Maximum permissible pressure losses in air inlet and exhaust gases outlet installations MODEL Air diaphragma Exhaust gases diaphragma Maximum permissible pressure loss (Pa) Height (mm) Code Height (mm) Code Maximum Minimum not recommended Pressure losses in straight ducts MODEL Air diaphragma Exhaust gases diaphragma Pressure loss in duct (Pa/m) Pressure loss in duct(pa/m) H (mm) CODICE H (mm) Kod Ø110 Ø130 Ø110 Ø ,46 0,20 0,17 0, ,99 0,43 0,36 0, ,95 0,42 0,34 0, ,21 0,53 0,45 0, ,11 0,49 0,41 0,18 2,07 0,91 0,72 0, ,04 0,90 0,72 0, ,09 0,92 0,73 0, ,03 1,34 1,10 0, ,03 1,34 1,10 0, ,02 1,33 1,03 0, ,02 1,33 1,03 0,45 4,82 2,12 1,49 0, ,49 2,42 1,73 0, ,16 2,27 1,66 0,73 not recommended ATTENTION For 90 o bend assume pressure losses like for straight 1,5 m duct. For T joint assume pressure losses like for straight 2 m duct. For 45 o bend assume pressure losses like for straight 0,75 m duct. 34
35 Selection of chimney packages M, MC SERIES Pressure losses in concentric ducts (additional equipment) MODEL Air diaphragma Exhaust gases diaphragma Pressure loss in concentric chimney Ø100 / Ø150 (Pa) Pressure loss in concentric chimney Ø130 / Ø200 (Pa) H (mm) Kod. H (mm) Kod. ME1 MF1 ME2 MF ,8 6,5 2,0 2, not recommended 11,5 12,8 4,5 5, ,5 12,8 4,5 5, ,0 20,0 5,0 5, ,0 20,0 5,0 5,6 29,0 32,4 9,5 10, ,5 10, ,5 10,7 10,5 11, ,5 11,8 10,0 11, ,0 11,3 29,5 33, ,5 33, Examples of calculations The M 35 heater with 50 mm diaphragm at exhaust gases side. Chimney system consists of following elements: 3 meters of Ø110 duct at exhaust gases side, 2 90 o bends Ø110 at the exhaust gases side, 1 meter of Ø130 duct at the combustion air inlet side Type of duct Quantity Pressure loss Sum Duct Ø ,09 Pa = 6,27 Pa+ Bends 90 Ø ,09 Pa = 6,27 Pa+ Duct Ø ,32 Pa = 0,32 Pa Total loss 12,86 Pa Total pressure loss in the chimney is higher than the maximum permissible loss of 12 Pa. This prevents the use of such a chimney configuration. In this case, you can take the following steps: Change the diaphragm to 40 mm, which will increase the maximum allowable pressure loss in the chimney system up to 24 Pa Increase the diameter of the exhaust gases duct to ø130, Reduce the length of the exhaust gases duct as far as possible. In this case the diaphragma can not be removed - it would reduce the overall pressure drop below the required minimum. 35
36 Selection of chimney packages B, G, F1, F1 C SERIES Maximum permissible pressure losses in air inlet and exhaust gases outlet installations Model Max. permissible pressure loss (Pa) B G G G G F F1 21 C 25 F F F1 41 C 80 F F1 51 C 106 Pressure losses in straight ducts Model Pressure losses for Ø80 Ø80 / Ø125 Ø100 / Ø150 Duct (Pa/m) Bend 90 (Pa) Concentric duct (Pa/m) Concentric duct (Pa/m) exhaust gases air exhaust gases air wall roof roof B 15 0,7 0,4 1,0 0,9 1,6 2,5 1,0 G 30 3,8 2,4 7,6 3,6 15,0 15,0 G 45 6,0 4,0 11,0 5,0 20,0 18,0 G 60 8,0 6,5 17,0 10,0 G ,0 17,0 36,0 24,0 F1 21 / F1 21 C 0,9 0,5 1,0 1,0 1,7 2,1 1,2 F1 31 1,4 0,7 2,6 1,3 3,2 8,7 5,1 F1 41 / F1 41 C 2,0 1,0 4,2 1,8 4,9 14,6 10,1 F1 51 / F1 51 C 2,3 1,6 6,5 3,5 9,7 27,6 16,9 not recommended Examples of calculations The G 100 heater with Ø80 exhaust gases duct. Chimney system consists of following elements: 6 meters of Ø80 duct at exhaust gases side, 1 Bend 90 o bend Ø80 at the exhaust gases side, 3 meters of Ø80 duct at the combustion air inlet side Type of duct Quantity Pressure loss Sum Duct Ø Pa = 132 Pa+ Bends 90 Ø80 (2x1,5) 3 36 Pa = 36 Pa+ Duct Ø Pa = 51 Pa Total loss 219 Pa Total pressure loss in the chimney is higher than the maximum permissible loss of 200 Pa. This prevents the use of such a chimney configuration. In this case, you can take the following steps: Increase the diameter of the exhaust gases duct, Reduce the length of the exhaust gases duct as far as possible. 36
37 Selection of ventilation air inlet Selection of fresh air inlet (ventilation) Selection of fresh air inlet relies on determining the surface of the hole, assuming a determined air velocity. In case of inlet assumed speed is from 2 to 4 m/s in net hole, it is recommended to assume 2 m/s. Net section is an active area of inlet, after deducting the surface of the dampers, thins, protective mesh etc., and is the characteristic parameter given by the manufacturer depending on the construction. Methods of selecting inlets are usually given by the manufacturer with selection nomograms but you can also use the following formula: where: P czynna active area of air inlet, after calculation select the inlet with similar area [m 2 ] V air stream flowing through the air inlet, depending on type of unit and recirculation rate [m 3 /s] v air velocity through the air inlet, it is recommended to assume 2 [m/s] [m/s] Exemplary selection of minimum active area of air inlet for Robur F1 41 C with mixing chamber: Air inlet should be selected from manufacturers catalogues according to this value. Selection of a suitable air inlet area is very important, too small active area can cause: excessive pressure drop in the air inlet site, resulting in smaller air flow through the unit which in turn may lead to overheating and signaling failure status of the heater, excessive noise at air velocity above 4 m s (obvious effect of exceeding the recommended air velocity for the air intake will be e.g. a distinctive whistle). The location of ventilation air inlet in relation to the exhaust gases outlet (the end of the exhaust duct) is strictly defined by law and depends on many factors, such as location in relation to the windows, neighboring buildings, etc. Each time, it should be analyzed and the appropriate air/exhaust and ventilation ducts lengths should be selected. Detailed guidelines can be found in the Regulation of the Minister of Infrastructure from 12 April 2002 about technical conditions to be met by buildings and their location, with further changes. 37
38 notepad 38
39 notepad 39
40 2015/2016 v.1
Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23
Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,
More informationDUCTLESS VENTILATION WITH HEAT RECOVERY. OXeN ductless ventilation unit
DUCTLESS VENTILATION WITH HEAT RECOVERY OXeN ductless ventilation unit OXeN DUCTLESS VENTILATION UNIT Simple ventilation solution OXeN ventilation unit is: the easiest way to create mechanical ventilation
More informationGas-fired unit heaters for indoor installation
UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat
More informationENERGY TOP. Condensing boiler solutions
ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for
More informationOXeN. Ductless ventilation with heat recovery.
OXeN Ductless ventilation with heat recovery www.flowair.com We are an expert in providing complete heating and ventilation solutions for medium and big cubature buildings. Our offer consists of three
More informationGas Unit Heaters PRODUCT LITERATURE. The right choice can make all the difference
Gas Unit Heaters PRODUCT LITERATURE The right choice can make all the difference ROBUR ROBUR VALUES Mission Robur is dedicated to dynamic progression in research, development and promotion of safe, environmentally-friendly,
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More informationGAS AIR HEATER RANGE
GAS AIR HEATER RANGE ATH Horizontal gas air heater ATC Centrifugal gas air heater ATV Vertical gas air heater Address : Yahtec - 6 rue Pascal 7700 Meaux - France Phone number :+ (0) 60 4 4 86 Multiple
More informationThe ideal solution for space heating integration
The easiest and the most cost-effective heating Gas fired unit heaters The ideal solution for space heating integration Independent gas fired convectors www.robur.com export@robur.it Always close to our
More informationSTATIONARY HOT AIR HEATING SYSTEMS
STATIONARY HOT AIR HEATING SYSTEMS Stationary hot air heating systems Wall-mounted heating systems Universal heating systems Hot water heating systems Ceiling ventilation units Ceiling heating systems
More informationVICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power
VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode
More informationOXeN. Ductless ventilation with heat recovery.
OXeN Ductless ventilation with heat recovery www.flowair.com FLOWAIR System COMPLETE HEATING AND VENTILATION SOLUTIONS FLOWAIR has a complete heating and ventilation system for industrial and public buildings.
More informationHeating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL
Heating, Air Conditioning, Ventilation Отопление-Кондиционеры-Вентиляция MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL 1. Usage MTM 8-30 universal oil heater is designed for heating commercial rooms
More informationGAS UNIT HEATERS ARM RANGE
GAS UNIT HEATERS ARM RANGE ARM Simple and reliable heater Efficiency up to % Fleaxiheat Gas Unit Heaters - ARM series are suitable for indoor installation in industrial and commercial premises. Thanks
More informationEOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION
EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION AXIAL FANS AND CENTRIFUGAL FANS HEATING COOLING GREEN ENERGY EOLO VIP: NEW! VERY IMPORTANT PERFORMANCE The
More informationCondensing, pre-mixed, wall-hung gas boilers with water tank
C 271-01 made in Italy Nias condensing Condensing, pre-mixed, wall-hung gas boilers with water tank Life-enhancing heat GB Condensing, pre-mixed, wall-hung boilers with water tank Nias CONDENSING HIGH
More informationVICTRIX Superior kw Export VICTRIX Superior kw X Export
Wall-hung condensing VICTRIX Superior kw is the instantaneous sealed chamber wallhung boiler with power of 32 kw which, thanks to condensation technology, is characterised for its high efficiency and guarantees
More informationThe competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28
The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationCI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS
CI/SfB 56.83 X RHeco Series CONDENSING GAS FIRED UNIT HEATERS RHeco Series CONDENSING GAS FIRED UNIT HEATERS Introduction Features & Benefits Model Range Reznor continue their tradition of manufacturing
More informationRapid. Suspended Warm Air Heater. Caring for the environment!
Rapid Suspended Warm Air Heater Caring for the environment! RAPID The QUICK and ECOLOGICAL Suspended Heater Our RAPID heaters were conceived and designed for the heating of industrial and commercial buildings.
More informationSTATIONARY HOT AIR HEATING SYSTEMS
STATIONARY HOT AIR HEATING SYSTEMS Stationary hot air heating systems Wall-mounted heating systems Universal heating systems Hot water heating systems Ceiling ventilation units Ceiling heating systems
More informationCITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready
CITY PLUS Wall-hung condensing boilers 24 HE 30 HE ErP Ready Quality first of all! Quality components Only the best components are used in the Italtherm boilers Noble materials Brass hydraulic groups,
More informationTERM-E ELECTRIC HEATING AND VENTILATION UNITS
ELECTRIC HEATING AND VENTILATION UNITS INTENDED USE The heating units with axial fans, metal casing and electric heaters are designed to heat rooms such as: industrial halls, workshops, warehouses, commercial
More informationSolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.
SolarWall Fan Units Introduction The SolarWall fan units are designed to be used maximize the supply of solar heated air into the building via fabric ducting. The units are complete with modulating dampers
More informationRIELLO 40 GS/M SERIES
The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationOnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!
OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.
More information... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...
LCSA - LCSBD - LCSC Gas Fired Unit Heaters LCSA complete with horizontal and optional vertical louvres LCSA - LCSBD - LCSC... Gas Fired Unit Heaters... The new LCSA builds on the technical excellence of
More information... UDSA - UDSBD Gas fired unit heaters...
UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat
More informationBENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS
BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new
More informationPORTABLE HEATERS FOR PROFESSIONAL USE
PORTABLE HEATERS FOR PROFESSIONAL USE www.mcs-heaters.com MASTER CLIMATE SOLUTIONS IS A WORLD LEADER IN THE PRODUCTION OF PORTABLE EQUIPMENTS FOR:, DEHUMIDIFICATION AND COOLING HEADQUARTERS MCS CLIMATE
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationCI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS
CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired
More informationPORTABLE HEATERS FOR PROFESSIONAL use
PORTABLE HEATERS FOR PROFESSIONAL use www.mcs-heaters.com MASTER CLIMATE SOLuTIONS IS A WORLD LEADER IN THE PRODuCTION OF PORTABLE EQuIPMENTS FOR:, DEHuMIDIFICATION AND COOLING HEADQuARTERS MCS CLIMATE
More informationVMA-VMB NOVA AIR HEATERS. NoVa air heaters
VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationSuperior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw
Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency
More informationCP+ Gas & Oil Cabinet Heater Range
CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationPREEVA air handling unit
APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu
More informationEnergy-efficient heat source provides comfort in large rooms
AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating
More informationAVIO kw Export 1 FEATURES. Wall-mounted with storage tank
1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO
More informationSIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A
cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors
More informationCeiling air diffuser INDULTHERM INDULTHERM-e
Technical Information Ceiling air diffuser INDULTHERM INDULTHERM-e Effective cooling and heating with a diffuser Thermomechanical or electrical switching Draught-free air distribution for cooling down
More informationProducts and prices. CLIMATE TECHNOLOGY feels better, works better.
Products and prices CLIMATE TECHNOLOGY feels better, works better. www.markclimate.com Long-term leaders in climate management Get to know the specialist in the Netherlands in the field of air heating,
More informationOperating manual. Pellet boiler. Orlan Pellet ISO 9001
Operating manual Pellet boiler Orlan Pellet ISO 9001 Contens 1. Boiler s use...................................................................... 3 2. Boiler s way of working...........................................................
More informationALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)
ALKON CARGO ALKON CARGO model Max/min nominal output Heat input condensing Non-condensing η condensation at 30 part load 35 7,4 35,1 6,7 33,5 34,8 106,3 Efficiency class (directive 92/42) ALKON CARGO is
More informationTechnical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW
Technical documentation ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW ComfortLine gas condensing boilers Benefits of the WOLF gas condensing boilers up to 24 kw CGB-2(K) / CGW-2 / CGS-2
More informationAir distribution systems. Opticlean OC-Q...
Air distribution systems OC-Q... DS 136 E 06.013 Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the OC-Q in order to combine in a single
More informationRoofVent Design Handbook
RoofVent Design Handbook Supply and Extract Air Handling Units for Heating and Cooling High Spaces RoofVent RH RC RHC R Content RoofVent RH RC RHC R RoofVent RH Supply and extract air handling unit with
More informationErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.
OPERATIONS MANUAL FOR AIR HEATER PROTON EL ErP 2015 05010416 05022916 PROTON EL Electric heating Safety precautions Construction and dimensions Technical parameters Installation EN RU www.protongroup.org
More informationSince 1983 Nuova COTERM has developed a wide range of water heaters.
Since 1983 Nuova COTERM has developed a wide range of water heaters. Thank to careful attention to market demands and continuous research towards new solutions, Nuova COTERM is able to offer clients the
More information24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus
24-28 kw Conventional Combi Gas Boiler Lawa / LawaPlus Conventional Combi Gas Boilers Warmhaus wall-hung gas combi boilers Lawa and LawaPlus, with the advantage of its width as 288mm, are easily fit to
More informationCOND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters
M 30 RE Heating only for outdoor installation with standard remote control Air heater Aeroclima STYLE 10-15 hot/cold M 50 With stainless steel frame for outdoor installation M 75 - M 100 For outdoor installation
More informationMCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS
MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to
More informationVICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers
Wall mounted condensing boilers VICTRIX 50 is the new wall-mounted central heating condensing boiler. It is pre-arranged for single and cascade operation (up to 3 appliances connected), with the advantage
More informationC Tahiti. condensing
C 227-01 m a d e i n I ta ly Tahiti condensing Condensing, pre-mixed, wall-hung boilers KC 24 KC 28 - KC 32 indoor, instantaneous, combination boilers KR 24 KR 38 - KR 32 indoor, central heating only boilers
More informationAir Handling Units. T F E.
Air Handling Units Extract from BS EN ISO 15138:2007 Petroleum & natural gas industries- Offshore production installations-heating, ventilation & air-conditioning. A.12.1 Function Installations provided
More informationWOLF VENTILATION SYSTEM PRICE LIST
VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation
More informationRemeha. Fuel oil/gas boilers P 520. Installation and Service Manual A
Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationWOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE
WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE CGB-2(K) / CGW-2 / CGS-2L / CGS-2R / CSZ-2 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial
More informationVERSO Air Handling Units
Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system
More informationVPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning
VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed
More informationPK-N Floor Standing Heater
PK-N Floor Standing Heater The experience is mixed with technology A solution for any necessity High efficiency Heat exchanger in inox steel 55 PK-N: the heat that lasts in time Apen Group has redesigned
More informationWOLF GAS CONDENSING BOILERS COMFORTLINE
WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build
More informationWe offer ceramic radiant heaters and infra-red radiant tubes.
When considering the choice of a new energy-efficient heating system for halls, warehouses, workshops or greenhouses, we should definitely consider gas-powered radiant heating. State-of-the-art heating
More informationTermEfekt USER S MANUAL AIR HEATER. Model PGA 14
Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification
More informationU tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45
U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS
More informationCONDENSING HIGH EFFICIENCY BOILERS
Built by 3I Innovative Industrial Inc. ABS Series CONDENSING HIGH EFFICIENCY BOILERS ABS 1500-2000-2500-3000-4000MBH Cast aluminum heat exchanger 10 to 1 turndown ratio Honeywell Sola boiler control system
More informationPORTABLE HEATERS MCS GROUP.
PORTABLE HEATERS MCS GROUP www.mcsworld.com I CHOOSE MASTER PORTABLE HEATERS. WHY? SAVE MONEY heaters are plug and play: do not need installation USE THE SAME HEATER IN DIFFERENT PLACES heaters are portable
More informationContact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.
Contact, Overview, Index Ceiling Heating/Chilled Plexus Professor Pilot Architect Polaris I & S Plafond Podium Celo Cabinett Capella Fasadium Atrium H & C /Loggia Regula Drypac TM Lighting TEKNOsim 0 0.00
More informationUnits for suspended ceilings
X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings
More informationDivacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production
Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation
More informationlindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles
lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles 2 We simplify construction At Lindab we are driven by a strong desire to continuously generate improvements and to
More informationAxial fans The right fan for every house
Axial fans The right fan for every house Axial fans with frame for incorporation into walls Big Dutchman offers a wide range of axial fan types. This variety allows us to meet all the climate requirements
More informationAluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support
Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationExtraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems
Extraction systems for the electronic industry Soldering workstations... 99 Soldering smoke extraction systems... 101 Accessories and spare parts... 102 98 Extraction and filter unit for soldering workstations
More informationAir distribution systems. Opticlean OC-Q... DS 4136 E /1
Air distribution systems Opticlean OC-Q... DS 136 E 06.13/1 Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the Opticlean OC-Q in order
More informationINSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400
INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400 Content 1. Delivery......................................................................... 3 2. Installation and assembly.........................................................
More informationSeries VENTS VUT R WH ЕС
AIR HANDLING UNITS WITH HEAT RECOVERY Series VENTS EH ЕС Series VENTS WH ЕС Air handling units with the air capacity up to 1500 m 3 /h in soundand heat-insulated casing with integrated electric heater.
More informationEOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION
EOLO B RT CONDENSING AND MODULATING ROOF-TOP GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION MORE CENTRIFUGAL FAN CONFIGURATIONS HEATING COOLING GREEN ENERGY EOLO B RT: NEW The new condensing and
More informationEuron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS
Euron Compact Wall Mounted as Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Compact, Efficient & Easy to Install & Maintain The Euron range of wall mounted gas fired condensing boilers
More informationWall-mounted air heaters for outdoor installation MEC EX C
all-mounted air heaters for outdoor installation for ducted outdoor installation wall-mounted air heaters have been specifically designed and certified for outdoor installation. he units are equipped with
More informationLOW NOx MODULATING GAS BURNERS
RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw
More information... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More information... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
... RHeco... ErP 2021 ErP Lot 21 Seasonal Efficiency and NOx compliant RHeco...... Reznor continue their tradition of manufacturing high efficiency warm air heating equipment with the introduction of the
More informationMOBILE HOT AIR HEATING SYSTEMS
MOBILE HOT AIR HEATING SYSTEMS Issue 2012 Mobile hot air heating systems Mobile Heaters Heating Centers Quality with systems RAPID HEAT ADAPTED TO YOUR NEEDS Hot air heating systems for air, to feel good,
More informationTECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES
TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES ENG Technical documentation Table of contents 1. INTRODUCTION 1.1 PRECAUTIONS 1.2 TRANSPORT 1.3 PACKAGE CONTENT 1.4 USE AND PRINCIPLE
More informationHITON - heat your home, not the planet 1 ENG
INSTRUKCJA OBSŁUGI NAGRZEWNICY NA OLEJ UNIWESALNY HP 145 i HP 145R USER MANUAL UNIVERSAL OIL HEATER HP 145 and HP 145R LUFTERHITZER FÜR MB-ÖL HP 145 und HP 145R BEDIENUNSANLEITUNG ИНСТРУКЦИЯ ЭКСПЛУАТАЦИИ
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationCiao Green Condensing Wall-Hung Boilers
Ciao Green Condensing Wall-Hung Boilers Residential Heating Ciao Green A cost-consciuos condensing boiler CIAO GREEN is one of the condensing boilers with the best price-quality ratio on the matket. Kitchen
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and
More informationWALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C
ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on
More information