Size: px
Start display at page:

Download "Refrigerated & Desiccant Compressed Air Dryer Product Selector"

Transcription

1 Refrigerated & Desiccant Compressed Air Dryer Product Selector ASD and HTD Series Refrigerated Dryer Units DD Series Desiccant Dryer Units Service Parts For faster service and to avoid errors, please use the fax as noted below or us at Website: DV Systems - Canada 490 Welham Road Barrie, ON, Canada L4N 8Z4 Ph: (705) Fax: (705) DV Systems US 128 Talbert Road, Suite B Mooresville, NC Ph: (704) Fax: (704)

2 Table of Contents. The Purpose for Using a Dryer Unit A Brief Physics Lesson 3 The Purpose of a Dryer 3 DV Systems Compressed Air Dryer Line Refrigerated Dryer and Desiccant Dryer Chart 3 Refrigerated Dryer Units Compressed Air and Refrigeration Circuit 4 Comparison of DV Systems ASD and HTD Dryers 5 Cycling versus Non Cycling Dryers 5 Refrigerated Dryer Basic Information 6 Typical Installation 7 Typical Dryer Operation 8 Most Common Fault Codes 8 Standard Replacement Parts 9 Page Desiccant Dryer Units Dryer Overview 10 Desiccant Dryer Operation 11 Desiccant Dryer Basic Information 11 Standard Maintenance Kits / Parts

3 The Purpose for Using a Dryer Unit. A Brief Physics Lesson. Though not readily visible, water vapour is present in the atmosphere that we live in. When an Air Compressor is used to increase the pressure of air from atmospheric to something higher, the increase in pressure tends to force the water vapour to condense into water droplets. As there is a great deal of heat present in the compressing of the air, and the warmer the air temperature the more moisture it can hold, the hotter compressed air leaves the Compressor Unit with all the moisture present in a vapour state. In other words, the air has all the moisture in it still in vapour form, none of it has changed to a liquid state. As the compressed air travels through the compressed air system, and cools down to ambient (room) temperature, the water vapour held in the air begins to condense into liquid droplets inside the air lines. The temperature at which the water vapour begins to form into liquid droplets is known as the dew point. The purpose of a Dryer. Air containing moisture may not be harmful to some industries, but it may be very harmful to others. Applications such as the autobody refinish industry and HVAC installations are areas where moisture content (or lack there-of) is very critical, resulting in inferior finishes or damaged controls and componentry. With a Compressed Air Dryer, the compressed air is cooled down to a temperature at which the moisture content is condensed into a liquid state. The key to the Dryer Unit is the ability to dry the air at a dew point temperature below the lowest temperature to which the compressed air will be exposed. With a properly sized and maintained Air Dryer, and coupled with suitable filtration, moisture at your point of use will be non-existent. With a Compressed Air Dryer: Tool life will increase while tool maintenance will be reduced. Air consumption will be reduced. More air is used when it contains water, oil, etc in order to blow out sludge. Production will be increased. Workers can use their tools immediately, as there is no need to purge water or contaminants from the air lines. Piping life is extended indefinitely as internal water corrosion is eliminated. Production quality is improved and maintained there. Poor air quality may cause poor product quality, increased rejects, and production shut-downs because of malfunctioning controls and tools. Trap maintenance down-stream of your Air Dryer is almost eliminated. New installations will not require pitched air lines, drop legs, traps, or drains. DV Systems Compressed Air Dryer Product Line. DV Systems offers (2) types of Compressed Air Dryers, namely the Refrigerated Dryers and the Desiccant Dryer lines. Though the Units achieve the same goal and are thus similar in that way, there are also notable differences in how that goal is attained. Refrigerated Air Dryer Desiccant Air Dryer Minimum Dew Point Achieved: Approx. 1 C (33 F) Approx -40 C (-40 F) Type of Medium Used: Freon Refrigerant Desiccant Beads Refrigerant Compressor Twin Desiccant Towers Power Requirement: To 100 CFM: CFM to 400 CFM: CFM+: Central Processor: Programmable Control Board Programmable Logic Relay - 3 -

4 Refrigerated Dryer Units. Compressed Air and Refrigeration Circuits. As indicated on the chart on the previous page, the Refrigerated Air Dryers use Freon to cool the compressed air down to approximately 1 C. Noted below is the process in which the air is cooled and the moisture removed. As shown below, the compressed air: enters the Dryer Unit and passes through the Heat Exchanger. as the air is cooled, water vapour is condensed into water droplets. the water droplets collect in the Condensate Separator and Tubing, and are evacuated from the Dryer by means of the Electronic Autodrain. In the Refrigeration Circuit: the Low Pressure/Low Temperature Liquid Refrigerant ❶ enters the Air to Refrigerant Heat Exchanger where a) it cools the compressed air and b) heat from the compressed air causes the Refrigerant to boil, vapourizing into a liquid the Low Pressure/High Temperature Gas ❷ flows to the Compressor in the Compressor, the Freon Refrigerant is converted to a High Pressure/High Temperature Gas ❸. It then enters the Condenser where it is cooled to a High Pressure/Low Temperature Liquid ❹. The Refrigerant then travels through the Capillary Tube (or Expansion Valve) which decreases the pressure of the Refrigerant making it a Low Pressure/Low Temperature Liquid Heat Exchanger 1 Air to Air 2 Air to Refrigerant Compressed Air Out ❶ 2 1 Capillary Tube or Expansion Valve Compressed Air In Condensate Separator ❷ Moisture Outlet Refrigerant Compressor ❹ ❸ Condensate Tubing Electronic Autodrain Refrigerant States Condenser And Fan ❶: LP/LT Liquid ❷: LP/HT Gas ❸: HP/HT Gas ❹: HP/LT Liquid - 4 -

5 Refrigerated Dryer Units (cont d). Comparison of DV Systems ASD and HTD Dryers. Within the DV Systems Refrigerated Dryer Unit category, there are two types of Dryers as indicated below. The chart differentiates between the two Dryer types. ASD Refrigerated Dryer HTD Refrigerated Dryer Refrigerant Dew Point 1 C 4 C (33 F 39 F) 3 C (37 F) Maximum Inlet Temperature 49 C (120 F) 83 C (180 F) Suggested Length of Pipe to Dryer Approx. 20 feet Minimum 3 to 4 feet Maximum Inlet Pressure Controls Available 232 psig (16 Bar) up to ASD psig (14 Bar) ASD150 to psig (12 Bar) ASD400 & 500 Controlled by Microprocessor Digital Dew Point Indicator Some Unit parameters adjustable 232 psig (16 Bar) Controlled by Microprocessor Digital Dew Point Indicator Some Unit parameters adjustable Initial In-Line Air Strainer 3 Micron Suggested 3 Micron Suggested Internal Filter High Efficiency Stainless Steel High Efficiency Stainless Steel Internal Autodrain Yes, Electronic Yes, Electronic Internal Aftercooler No Yes 1. Maximum Inlet Temperature is the maximum allowable temperature of the compressed air to enter the Dryer Inlet. 2. Suggested Length of Pipe to Dryer is simply the suggested amount of piping required between the Compressor Outlet and Dryer Inlet to ensure the temperature of the compressed air does not exceed the Maximum Inlet Temperature. 3. Maximum Inlet Pressure is the maximum allowable air pressure entering the Dryer Unit. 4. Initial In-Line Strainer is a pre-filter to the Dryer Inlet, and would remove large contaminants from the compressed air before entering the Dryer. The Strainer must be purchased separately. 5. Internal Filter separates the water from the compressed air after the compressed air has been cooled. 6. Internal Autodrain drains the moisture from the Dryer. 7. Internal Aftercooler is a means of pre-cooling the compressed air immediately after it enters the Dryer Unit. It allows the Unit to be located closer to the Compressor Unit. Cycling versus Non Cycling Dryer Units. There are two basis designs for Refrigerated Air Dryers. Though DV Systems Units are considered Non Cycling Dryers, it is useful to know both designs and how they differ. Non Cycling Dryers: Continually circulate refrigerant through the system When there is a steady flow of compressed air through the Unit, the Refrigerant Compressor will operate constantly. A period of reduced load will either: o Cause a change in the regulation of the refrigerant in the Unit or o Put the Unit into a sleep mode. Cycling Dryers: Uses Refrigerant to cool an internal thermal mass (commonly liquid glycol). The Refrigerant Compressor works intermittently, starting only when the mass temperature has increased. Though there may be some energy savings, the purchase price of these Units is somewhat more expensive

6 Refrigerated Dryer Units (cont d). Refrigerated Dryer Basic Information. Noted in the charts below is basic information concerning both the ASD and HTD Series of DV Systems Refrigerated Air Dryers. This information is helpful for both ordering a Unit and ensuring the installer is aware of the requirements. ASD Series of Refrigerant Dryer. Model: SCFM Air Compressor HP Electrics Full Load Current Inlet/Outlet Ports Weight ASD10 10 <5 HP 2.21 A 3/8 18 kg/40 lb ASD HP ASD , 7½ HP 2.91 A 27 kg/60 lb ½ ASD HP 5.24 A 28 kg/62 lb ASD HP 6.96 A 35 kg/77 lb ¾ ASD , 25, 30 HP 9.82 A 47 kg/104 lb ASD HP 7.35 A 87 kg/192 lb ASD HP 1½ NPT ASD HP 13.5 A 110 kg/243 lb ASD A 120 kg/264 lb ASD HP kg/286 lb A ASD kg/330 lb HTD Series of Refrigerant Dryer. Model: SCFM Air Compressor HP Electrics Full Load Current Inlet/Outlet Ports Weight HTD HP 5.24 A 28 kg/62 lb HTD ½ HP 2.95 A 38 kg/ 84 lb ½ HTD HP 5.24 A 39 kg/86 lb HTD HP 5.24 A 39 kg/86 lb - 6 -

7 Refrigerated Dryer Units (cont d). Typical Installation. Shown below are minimal clearances (in red) that should be maintained around a Refrigerated Dryer. It is critical that there be sufficient room around and above the Unit to ensure that there is good air flow through and around the Unit. Many issues are caused by the Unit over-heating, this caused by it being installed too closely to any adjacent wall, etc. Also: Place the Dryer in a cooler part of the shop. The refrigeration system requires relatively cool air to function at its optimum. When placed in a warmer environment, the refrigeration system must work much harder to cool the compressed air, thus becoming less efficient. The Unit should not be located in a dusty environment. The interior of the Dryer contains items that must be kept clean to work efficiently. Any build-up of dust and debris will limit the operation of the Unit, and may cause failure. Locating the Unit on a suitable pedestal will ensure that floor dust is not drawn into the Unit. As noted previously, the compressed air lines should have a 3 Micron Separator Filter (as indicated below) installed between the Air Compressor and the Refrigerated Dryer Unit. The Separator Filter will act as a pre-filter to the Dryer collecting any bulk liquids and solids 10 micron and larger. The Separator Filters are sold as the Canister and Filter Element separately, and are available in a variety of sizes to suit the Unit CFM. Bypasses c/w Ball Valves Clean, Dry Air 36 Min 18 Min 18 Min 6 Min Compressed Air From Compressor SAF-C Canister + SAF-S 3 Micron Element Compressed Air Dryer - 7 -

8 Refrigerated Dryer Units (cont d). Typical Dryer Operation. The typical Refrigerated Air Dryer will operate as follows: Pressing the On/Off Button for 3 seconds will start the Unit There is a delay of up to 2 minutes before the Refrigerant Compressor starts. The Condenser Fan will start approx. 30 seconds there-after. The Fan will not normally run at full speed, this indicated by a flashing LED The readout will initially show ambient temperature indicated by 3 horizontal bars on the readout Once the Fan and Compressor start, the dew point of the Unit will decrease to approx. 1 C, this indicated by 1 or no horizontal bars. Once at approx. 1 C, the Fan will stop, only to be called to run again once the temperature increases to approx. 5 C Pressing the On/Off Button (when the Unit is operating) will run the Fan at full speed for several seconds, after which the Unit will stop. (The LED will be on continually while the Fan runs at full speed.) O N The Unit is ON with a normal load and is operating correctly. As well as showing the dew point, the readout may indicate several fault codes as suggested below. Most Common Dryer Faults. The readout will indicate a variety of fault codes, the most common being as follows: E S A Energy Saving Mode. The Dew Point has been running at below -1 C for over 6 minutes. The Unit will automatically restart operation at 6 C. P F I Temperature Probe Alarm. The Temperature Probe is not working properly. It may not be connected to the Board, or the Probe may be defective. Replace the Probe if necessary. H t A High Temperature Alarm. The Dew Point has been running at above 12.5 C for over 6 minutes. The Unit must be manually turned off and on. The fault could be caused by a dirty radiator, high ambient temperature, a faulty Fan, or a faulty refrigerant Compressor, to name only a few. The manual which accompanies the Unit has a complete listing of the faults

9 Refrigerated Dryer Units (cont d). Standard Replacement Parts for Current Models. Part Number: Description: ASD Series Dryers HTD Series Dryers RD Fan Motor RD Fan Motor RD Fan Motor RD Fan Motor & Blade * * RD Drain Valve Assy RD Drain Valve Assy RD Temperature Probe RD Control Board RD Control Board * Note: For ASD150 and ASD200 Units having R407C Refrigerant, use Fan Motor RD Current Models have serial numbers equal to or greater than the following: Model Number: Serial Number: Model Number: Serial Number: ASD10 07M HTD18 07M ASD15 07M HTD26 07M ASD30 07M HTD37 07M ASD40 07M HTD52 07M ASD60 07M ASD100 07M ASD150 07M ASD200 07M Standard Replacement Parts for Older Models. Part Number: Description: ASD Series Dryers HTD Series Dryers RD Fan Motor RD Fan Motor RD Fan Motor & Blade RD Drain Valve Assy RD Drain Valve Assy RD Temperature Probe RD Control Board RD Control Board RD Control Board - 9 -

10 Desiccant Dryer Units. Dryer Overview. As indicated on the chart on page 3, the Desiccant Dryers use Desiccant Beads (also termed as Activated Alumina ) to trap the moisture while bringing the dew point down to approximately -40 C (-40 F). Shown below are front and rear views of a typical Desiccant Dryer Unit. Moisture Indicator Pressure Gauges (for LH & RH Towers) Controls include LED s and Start/Stop Switch Outlet Filter Desiccant Towers containing Beads Purge Valves and Silencers Inlet Valves Inlet Filter

11 Desiccant Dryer Units (cont d). Desiccant Dryer Operation. The Desiccant Dryer operation consist of four stages as follows: Drying Stage. The compressed air enters the Inlet Filter containing a High Efficiency Coalescing Filter Element which removes dirt particles 0.01 micron and larger, and 99+% of oil aerosols. The air then enters and flows upwards in the Desiccant Tower. As it flows upwards, it comes in contact with the Desiccant Beads, at which time the moisture in the compressed air is attracted to and adsorbed onto the surface of the Beads. The adsorbing is a heat releasing process that later contributes to the cleaning process. The cool, dry air exits the Tower and flows through the Outlet Filter containing a Coalescing Filter which removes dirt particles 1.0 micron and larger, and 99+% of water condensate. Regeneration Stage. As the one Tower is in the Drying Stage as indicated above, the second Tower is in the Regeneration Stage. A small percentage (approximately 15%) of the air travelling through the Drying Stage is redirected to the second Tower where it is used to release the moisture from the Desiccant Beads. The compressed air is allowed to escape from the Tower by way of a Purge Valve and Silencer. Repressurization Stage. Once the Regeneration Stage has taken place in the second Tower, the Purge Valve is closed, and the second Tower becomes pressurized. Changeover / Depressurization Stage. After the second Tower has been completely repressurized, the Controller signals the Valves to switch operation. The Tower that had been in the Drying Stage enters the Regeneration Stage. The Tower that was in the Repressurization Stage enters the Dryer Stage. Approximate Dryer Cycle Times are as follows: Complete Cycle: 10 minutes Drying Stage: 5 minutes Regeneration Stage: 4 minutes 15 seconds Repressurization Stage: 45 seconds Desiccant Dryer Basic Information. Noted in the chart below is basic information for the DV Systems Desiccant Air Dryers. Model: 100 psig Air Compressor HP Electrics Power Consump. Inlet/Outlet Ports Weight DD <10 HP ½ NPT 66 kg/145 lb DD HP DD HP ¾ NPT 109 kg/240 lb Watt DD HP 112 kg/245 lb DD HP 1 NPT 142 kg/311 lb DD HP

12 Desiccant Dryer Units (cont d). Standard Maintenance Kits / Parts. Item: Description: DD-28 DD-37 DD-60 DD-80 DD-100 DD-115 DD Maintenance Kit DD Maintenance Kit DD Maintenance Kit DD DD DD DD DD Maintenance Kit for Inlet Switch Valve Maintenance Kit for Repress. Valve Maintenance Kit for Inlet Switch Valve Maintenance Kit for Inlet Switch Valve Maintenance Kit for Repress. Valve DD Desiccant (50 lb Bag) (1) Req d (1) Req d (1) Req d (1) Req d (2) Req d (2) Req d Maintenance Kits DD and DD include: (1) SAF-A 1.0 Micron Filter Element (1) SAF-E 0.01 Micron Filter Element (2) DD Filter Silencer (100) DD Desiccant Beads (in lbs) Maintenance Kit DD includes: (1) SAF-A 1.0 Micron Filter Element (1) SAF-E 0.01 Micron Filter Element (2) DD Filter Silencer (150) DD Desiccant Beads (in lbs)

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Understanding Compressed Air Moisture

More information

Single Tower Heat Reactivated Desiccant Air Dryer

Single Tower Heat Reactivated Desiccant Air Dryer Single Tower Heat Reactivated Desiccant Air Dryer iste Dryer Understanding Compressed Air Moisture in compressed air is damaging. Using untreated air results in water and contaminants in your air lines,

More information

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air is damaging.

More information

DRYAIRE DESICCANT SYSTEM MODEL 6760

DRYAIRE DESICCANT SYSTEM MODEL 6760 MODEL 6760 THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance for removing dirt, water, oil, and

More information

Overview of HL series heatless regenerative dryers.

Overview of HL series heatless regenerative dryers. Overview of HL series heatless regenerative dryers. WWW.VANAIRSYSTEMS.COM Billbert www.vanairsystems.com Regenerative Desiccant Dryers MHL/HLS Series Heatless HL Series Heatless HI Series-Heated Internally

More information

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION Having an understanding of why water forms in your compressed air piping system will help you in evaluating the type of air drying system

More information

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page 150-3,000 scfm AEHD Series Desiccant Air Dryers AEHD Series Externally Heated Desiccant Air Dryer 150-3,000 scfm Front Page 1 AEHD Series Heated Dryer Externally Heated Desiccant Dryer 150-3,000 scfm Since

More information

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment FACT SHEET 3 How to save energy, reduce costs and help the environment COMPRESSED AIR TREATMENT All compressed air needs some form of treatment to achieve the desired air quality. This guide investigates

More information

CAMAIR THE LEADER IN DRY AIR TECHNOLOGY

CAMAIR THE LEADER IN DRY AIR TECHNOLOGY CAMAIR THE LEADER IN DRY AIR TECHNOLOGY INSTALLATION AND OPERATING INSTRUCTIONS XL100 Z Semi Automatic Dryer 1984 2007 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Receiving and Inspection Locating the dryer

More information

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual MR Series Heatless Mini Regenerative Desiccant Dryer Operator s Manual Introduction Many years of trouble-free service can be expected from your Numatics regenerative dryer. Superior dew point depression

More information

Compressed Air Dryers

Compressed Air Dryers The world s highest efficiency and heavy duty Desiccant at affordable prices Up to 300 SCFM Point of use dryers Supplement to a central system Zero air loss Applications: Sand Blasting Paint Spraying Dust

More information

HEATLESS REGENERATIVE DRYERS

HEATLESS REGENERATIVE DRYERS HEATLESS REGENERATIVE DRYERS PHL SERIES Pioneer Air Systems Inc. 210, Flatfork Road, Wartburg, TN - 37887 Tel. : (423) 346-6693 Fax : (423) 346-3865, (423) 346-7522 Email : sales@pioneerair.com Internet

More information

Hybrid Refrigerated/Desiccant Compressed Air Dryers

Hybrid Refrigerated/Desiccant Compressed Air Dryers Hybrid Refrigerated/Desiccant Compressed Air Dryers This paper first appeared at the 2013 World Energy Engineering Congress Wayne Perry, Senior Technical Director David Phillips, Air Treatment Product

More information

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation Filtration Balston Membrane Nitrogen Generators Compressed Air Dryers 157 Parker Hannifin Corporation Membrane Air Dryers Provide Clean, Dry Compressed Air Offer a reliable, efficient, and economical alternative

More information

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector As appeared in March 2017 PBE Copyright CSC Publishing www.powderbulk.com Preventing moisture problems in your dust collector Brian Mathews Scientific Dust Collectors This article discusses how moisture

More information

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr) D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm3/hr) D D D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm 3 /hr) Leading

More information

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series HEAT OF COMPRESSION DESICCANT AIR DRYERS DHC Series Why Heat of Compression? The DHC Series heat of compression desiccant air dryers from Gardner Denver provide an energy efficient solution to remove moisture

More information

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL DATE OF PURCHASE: MODEL: SERIAL NO.: Record above information from nameplate. Retain this information for future reference.

More information

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr Ingersoll Rand Heatless and Heated Blower Desiccant Air Dryers 160-14,900 m 3 /hr Innovative Design is Now Within Reach Ingersoll Rand Ingersoll Rand heatless and heated blower desiccant dryers are engineered

More information

Desiccant Air Dryers. Heatless, Heated and Heated Blower

Desiccant Air Dryers. Heatless, Heated and Heated Blower Desiccant Air Dryers Heatless, Heated and Heated Blower Desiccant Dryers... When we designed the Ingersoll Rand heatless, heated and heated blower desiccant dryers we set our sights on creating the most

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

Pressure Swing Desiccant Dryers

Pressure Swing Desiccant Dryers Pressure Swing Desiccant Dryers Featuring Legendary Heat-Les TM Technology The Original Heat Les Drying Technology The DHA / CDA series dryer has been designed specifically to bring you reliable performance

More information

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS REFRIGERATED COMPRESSED AIR DRYER WRA-0050 WRA-0200 WARNING READ ALL INFORMATION IN THIS MANUAL BEFORE BEGINNING INSTALLATION

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated Air Dryers Dual Control and Demand Manager Series 600-3000 scfm Energy Saving Refrigerated Dryers A Choice of Two Because compressed air demand fluctuates in some applications and is relatively

More information

Dual Tower Heat Reactivated Desiccant Air Dryer

Dual Tower Heat Reactivated Desiccant Air Dryer Dual Tower Heat Reactivated Desiccant Air Dryer idhpe Dryer idbpe Dryer Eliminate Water from Your Compressed Air System Moisture in compressed air is damaging. Without proper treatment, this vital energy

More information

By taking the trouble to eliminate the contaminants before the compressed air enters the equipment these costs can be significantly reduced.

By taking the trouble to eliminate the contaminants before the compressed air enters the equipment these costs can be significantly reduced. The Application Dryer with patented technology will eliminate water from your compressed air. Using a completely new approach it dries and filters all the contaminants at the point of use. Contaminants

More information

Heated Desiccant Air Dryer

Heated Desiccant Air Dryer OWNERS MANUAL F-0073 HEATED DESICCANT AIR DRYER Heated Desiccant Air Dryer MODELS RE231-RE250 ARROW PNEUMATICS Table of Contents Unpacking/Application/Analysis 3 Specifications 4 Dimensional Drawings 5-6

More information

Nitrogen Generation Systems Compressed Air Dryers

Nitrogen Generation Systems Compressed Air Dryers Nitrogen Generation Systems Balston Balston offers both membrane and PSA technology. Balston Membrane combine superior coalescing technology with a proven, innovative membrane system to supply clean, dry

More information

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular Desiccant Dryers Desiccant Dryers Heatless Heated Purge Blower Purge Modular Desiccant Air Dryers Quincy desiccant air dryers purify compressed air by adsorbing water vapor. Pressure dewpoints of -40 F

More information

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM Since 1946, the world has turned to SPX FLOW s Pneumatic Products brand for the quality and service demanded by the most critical

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770 DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770 System Includes: Air Filter w/overnight Drain (Part No. 22601) Coalescer w/overnight Drain (Part No. 22605) Air Regulator Assembly (Part No. 1640) Membrane

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL H-Series & 203 THRU 223 SERIES ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 2111 WEST 21ST STREET BROADVIEW, IL 60155 708-343-9595 708-343-1907

More information

H & HC Heat-Of-Compression Air Dryers

H & HC Heat-Of-Compression Air Dryers H & HC Heat-Of-Compression Air Dryers Air Quality Solutions by Ingersoll-Rand Introduction Heat-of-compression dryers are dual tower, desiccant designs. The HOC dryer is the most energy efficient dryer

More information

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series Regenerative Desiccant Dryers KAD, KED, KBD and Hybritec Series The Right Dryer For You Most compressed air applications require only refrigerated dryers; however, if your compressed air is exposed to

More information

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency Titus Air Systems TDD Series The Company Since 1986, our company has been known for delivering high quality compressed air and gas system solutions. In moving from being a local sales and service provider

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Operation & Maintenance Manual MODELS MDX 800 1000 1200 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY 2 1.0

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250 MDX Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap Operation & Maintenance Manual MDX MODELS 18 THRU 250 TABLE OF CONTENTS HOW TO USE THIS MANUAL 2 SYMBOLS 2 WARRANTY

More information

DGH Series Global Air Treatment

DGH Series Global Air Treatment DGH Series Global Air Treatment 2 DGH Desiccant Dryers Customizable Performance Gardner Denver DGH Series Heatless Desiccant Dryers were designed to help you meet your goals. Customizable performance technology

More information

Blower Purge Desiccant Compressed Air Dryer. HBP SERIES 500-4,300 SCFM ( nm 3 /h)

Blower Purge Desiccant Compressed Air Dryer. HBP SERIES 500-4,300 SCFM ( nm 3 /h) Blower Purge Desiccant Compressed Air Dryer HBP SERIES 500-4,300 SCFM (850-7306 nm 3 /h) HBP Series Blower Purge Desiccant Compressed Air Dryers HBP SERIES DRYERS PRODUCE 100% EFFICIENT AIR SYSTEMS HBP

More information

White paper Compressed air drying

White paper Compressed air drying White paper Compressed air drying White paper : Compressed air drying Table of content Introduction 4 Where does the water come from? 5 How to remove the water? 6 Drying methods 7 Refrigerant dryers 8

More information

Trident Breathing Air System

Trident Breathing Air System Trident Breathing Air System INSTALLATION, OPERATION, MAINTENANCE PSA Type Breathing Air Dryer Dealer: This manual MUST be given to the end user. User: BEFORE using this product, read this manual and preserve

More information

CFH Series High Efficiency Filters

CFH Series High Efficiency Filters CFH Series High Efficiency Filters Intelligent Air Technology Save energy, dollars & protect your air system The Compressed Air Challenge, a government/ industry sponsored energy savings awareness program,

More information

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h)

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h) Heat of Compression Desiccant Air Dryers HOC SERIES 350-10000 scfm (595-16990 nm 3 /h) Where Ideas Meet Industry HOC Series Deltech HOC Series heat of compression desiccant air dryers provide a cost effective

More information

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h) Heat of Compression Desiccant Air Dryers NRG-LES SERIES 350-10000 scfm (595-16990 nm 3 /h) Where Ideas Meet Industry Since 1946, the world has turned to SPX FLOW s Pneumatic Products brand for the quality

More information

www.compressedairsystems.com PURIFICATION SOLUTIONS D-Series1 ultra-high purity compressed air dryers flow capacity: 3-177 scfm (5-301 Nm /hr) 3 D 1 D-Series 1 ultra-high purity compressed air dryers D

More information

ingersoll rand desiccant dryers

ingersoll rand desiccant dryers Distributors For: Branch Directory: 149 Glasgow Road Wishaw Lanarkshire ML2 7QJ Tel 01698 355711 Fax 01698 359299 Wellheads Road Farburn Industrial Estate Dyce, Aberdeen AB21 7HG Tel 01224 723434 Fax 01224

More information

PET Drying Technology

PET Drying Technology PET Drying Technology Introduction Industry s increasing demand for clean, reliable sources of high pressure compressed air require that system designers become more educated in dehydration and filtration

More information

REFRIGERATED AIR DRYERS

REFRIGERATED AIR DRYERS QUINcy qpcd series CYCLING QUINcy qpnc series NON-CYCLING REFRIGERATED AIR DRYERS QPCD CYCLING DRYER, QPNC NON-CYCLING Cycling and non-cycling designs for maximum system efficiency Balanced refrigeration

More information

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often

More information

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment RHP & FHP Series High Pressure Air Treatment Global Air Treatment 2 High Pressure Air Treatment RHP Series Refrigerated Dryers and E Series Filters for 700 900 psig Applications The demand for clean, dry

More information

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often

More information

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr) snowstorm filled ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2 3 ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2

More information

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS INSTRUCTION MANUAL FOR WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS DE3 - DE5 OPERATIONS GENERAL This instruction manual covers the installation, operation, maintenance and troubleshooting

More information

Energy Impacts of Compressed Air

Energy Impacts of Compressed Air The Overlooked: Water 101/Plug Loads/Process Energy Impacts of Compressed Air Rusty Friend AMEC Foster Wheeler August 14, 2017 Tampa Convention Center Tampa, Florida Energy Impacts of Compressed Air Energy

More information

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm INSTRUCTION MANUAL DHW Series Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm FORM NO.: 3215738 REVISION: 07/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING

More information

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252 ARROW PNEUMATICS, INC. REGENERATIVE DRYER DIVISION 500 NORTH OAKWOOD RD LAKE ZURICH, IL,60047 PHONE # (847)

More information

CATALOGO TECNICO IN INGLESE

CATALOGO TECNICO IN INGLESE Duncan Rogers (Engineering) Ltd. CATALOGO TECNICO IN INGLESE The Application Dryer with patented technology will eliminate water from your compressed air. Using a completely new approach it dries and filters

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 30992L EN Model 23440 Maximum Operating Pressure 60 psi (. MPa, bar) Maximum Temperature 50 F (65 C) Model 24M78 Maximum Operating Pressure 75 psi

More information

Meeting Your Compressed Air Treatment Needs

Meeting Your Compressed Air Treatment Needs Compressed Air Treatment Guide Meeting Your Compressed Air Treatment Needs How to Select the Right Equipment for Your Application Provided as a Service by Kaeser Compressors, Inc. Six Levels of Compressed

More information

Modular Adsorption Dryers

Modular Adsorption Dryers 01 GB Modular Adsorption Dryers Highly efficient air treatment Innovative compressed air treatment A-Series Totally dry and clean air The A-Series modular compressed air dryers - a dedicated solution for

More information

Externally Heated Desiccant Air Dryer RP Series

Externally Heated Desiccant Air Dryer RP Series Externally Heated Desiccant Air Dryer RP Series Externally Heated Desiccant Compressed Air Dryers Reduce Purge Air Energy Costs For decades, compressed air users have relied on Deltechto deliver technology

More information

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series Desiccant Air Drying Technologies HCS Series HCL Series HCT Series HCS, HCL and HCT Series Heatless Dryers Models 40-450 Models 590-5400 HCS, HCL and HCT Series Heatless Desiccant Dryers Since 1961, compressed

More information

Atlas Copco. Refrigerant air dryers FX 1-21 ( l/s, cfm)

Atlas Copco. Refrigerant air dryers FX 1-21 ( l/s, cfm) Atlas Copco Refrigerant air dryers FX 1-21 (7-1236 l/s, 1-2516 cfm) Air treatment a smart investment Why invest in dry quality air? Wherever you go in the world, whatever application you look at, you will

More information

Desiccant Air Drying System

Desiccant Air Drying System Instructions - Parts List Desiccant Air Drying System 3099D Model 30 Maximum Operating Pressure 0 psi (. MPa, bar) Maximum Temperature 50 F (5 C) Includes: Part No. Description 30 Stage - Air Filter with

More information

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America Heatless Regenerative Compressed Air Dryers Compressed Air System Products Made in America 22 AIR/TAK Heatless Regenerative Air Dryers Compressed Air System Products That Save Energy & Improve Operations.

More information

Vertical Dryer Owner s Manual

Vertical Dryer Owner s Manual DSV-250, DSV-450, DSV-750, DSV-1000, DSV-1200 & DSV-1600 Models Model DSV-250 DSV-450 DSV-750 DSV-1000 DSV-1200 DSV-1600 Regulator Setting For Air Motors 22 PSI TO GET 3450 RPM 20 PSI TO GET 1725 RPM 22

More information

Heated purge desiccant compressed air dryers. hpd Series

Heated purge desiccant compressed air dryers. hpd Series Heated purge desiccant compressed air dryers hpd Series dedicated to excellence Since 1948, compressed air users around the world have relied on Hankison to provide innovative compressed air treatment

More information

HEATLESS DESICCANT AIR DRYERS

HEATLESS DESICCANT AIR DRYERS HEATLESS DESICCANT AIR DRYERS HHS, HHL AND HHE SERIES HANKISON HEATLESS DESICCANT DRYERS HHS, HHL AND HHE SERIES Since 1948, sensitive applications requiring clean, dry, compressed air have turned to Hankison

More information

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Pneutrol International limited, 5 Caulside Drive, Antrim, Northern Ireland, BT41 2DU Tel +44 (0)

Pneutrol International limited, 5 Caulside Drive, Antrim, Northern Ireland, BT41 2DU  Tel +44 (0) neutrol International limited, 5 Caulside Drive, Antrim, Northern Ireland, BT41 2DU www.pneutrolspares.com, sales@pneutrol.com, Tel +44 (0) 28 9448 The Application Dryer with patented technology will eliminate

More information

Quality Components as a basis for Quality Equipment

Quality Components as a basis for Quality Equipment Above & Beyond Regenerative Type Compressed Air Dryers SPS - Heatless Regenerative Dryers SPEH - External Heated Regenerative Dryers SPBS - Heated Blower Purge Regenerative Dryers Quality Components as

More information

Heatless Desiccant Compressed Air Dryers

Heatless Desiccant Compressed Air Dryers Heatless Desiccant Compressed Air Dryers Pro Dry Heatless Desiccant Compressed Air Dryer Inspired by its sophisticated predecessor, SMC can now boast an additional ten models to enhance the current Pro

More information

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series AirCel Heated Regenerative Desiccant Dryers AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why Dry Compressed Air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapor and airborne particles. These problems

More information

COMPRESSED AIR TREATMENT

COMPRESSED AIR TREATMENT COMPRESSED AIR TREATMENT HL Pro / HB SERIES DESICCANT DRYERS Innovative Design is Now Within Reach OMI heatless and heated blower desiccant Dryers are: - Engineered for easy access, maximum efficiency

More information

CPF PRODUCT DESCRIPTION

CPF PRODUCT DESCRIPTION CPF 175 340 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPF 175-340 compressor is a quiet, complete and ready-for-use unit for the production of compressed air in industrial applications. OVERVIEW The CHICAGO

More information

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm Dry air as low as -100 F pressure dew point Clean, dry compressed air solves the problems of moisture contamination

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

Compressed Air Specialists

Compressed Air Specialists Compressed Air Specialists Breathing Air Systems The Breathing Air Device (BRAD) ensures clean, contaminant free, Grade D breathable air to the painter, eliminating health hazards. RTi has several innovative

More information

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual MDX Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap Operation & Maintenance Manual MODELS MDX 1500 1800 2400 3000 TABLE OF CONTENTS 1.0 GENERAL 2 1.1 How to use this

More information

Benefits of Desiccant Dryer Dew Point & Purge Control

Benefits of Desiccant Dryer Dew Point & Purge Control Benefits of Desiccant Dryer Dew Point & Purge Control Sponsored by Featured Speaker: Hank van Ormer, Air Power USA For your free subscription, please visit http://www.airbestpractices.com/magazine/subscription.

More information

clean, dry compressed air

clean, dry compressed air clean, dry compressed air Adsorption Air Dryers Air and gas purification have been at the core of Xebec adsorption technology since 1967. We have built, installed and continue to service over 9000 dryers.

More information

CNC Series Refrigerated Air Dryer CFM

CNC Series Refrigerated Air Dryer CFM CNC Series Refrigerated Air Dryer 10 3000 CFM NEW Engineered to Save CNC Value CompAir leads the way in providing value to our customers We looked beyond the typical refrigerated air dryer and designed

More information

Industrial Oxygen Generation Plant

Industrial Oxygen Generation Plant Industrial Oxygen Generation Plant Operation Process Description : (Ref: P-I Diagram) Oxygen is generated from Compressed air by a separation process which uses the principle of selective adsorption. The

More information

Refrigerated Air Dryers

Refrigerated Air Dryers WRD Series Innovative Compressed Air Products Refrigerated Air Dryers. Innovative, High Quality, and Cost Effective Refrigerated Air Dryers Leading Edge Technology CORPORATION DEW POINT 0 10 15 C 32 50

More information

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S Polar Air Dryer R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S PDRCF1150029 PDRCF4602000 Instructions Manual TABLE OF CONTENTS 1. Important safety notes - Please read... 1 1.1. Transportation...

More information

K100 Rotary Screw Air Compressor Unit Installation And Start-up Data

K100 Rotary Screw Air Compressor Unit Installation And Start-up Data K100 Rotary Screw Air Compressor Unit - - - Installation And Start-up Data Quick Start... 2 Safety Precautions 5 Shipping Cleats 6 Unpacking and Inspection... 7 Installation Mechanical. 8 Lubrication.

More information

MDA-Range of Modular Desiccant Compressed Air System

MDA-Range of Modular Desiccant Compressed Air System MDA-Range of Modular Desiccant Compressed Air System Intelligent Air Technology MDA-Range of Modular Desiccant Compressed Air Dryers The Problem Compressed air is an essential power source that is widely

More information

RNC Series SCFM Global Air Treatment

RNC Series SCFM Global Air Treatment RNC Series 10 3000 SCFM Global Air Treatment 2 Durability Delivered Air Treatment Systems RNC Series refrigerated air dryers are engineered to benefit you today and tomorrow from the tradition of durability

More information

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm CDT Series Heatless Desiccant Air Dryers 40 5,400 SCfm ISO Quality Dew Points Three Controller Selection NEMA4 Electrical Construction Standard on Two Controllers Purge Optimal Savings 2 Personalized Performance

More information

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 7428146 Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138 1.0 SAFETY All compressed gases, including air, can be dangerous.

More information

Refrigerated Compressed Air Dryers

Refrigerated Compressed Air Dryers Refrigerated Compressed Air Dryers 5-6,000 scfm.14-170 m 3 /min Refrigerated Non-Cycling Refrigerated Cycling Refrigerated High Temperature OWS - 210 Sullair Capabilities Sullair Leadership Since 1965,

More information

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Section 10 Bulletin A -7 Pneumatech is proud to offer this range of reliable and innovative refrigerated air dryers. These dryers are a cost effective

More information

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

Membrane Dryer. Air inflow rate KMM Series to m 3 /min Membrane Dryer Air inflow rate KMM Series 0.08 to. m /min Why is it necessary to dry compressed air? The atmospheric air drawn into a compressor is a mixture of gases that always contains water vapour.

More information

Refrigerated Compressed Air Dryers 5-6,000 scfm

Refrigerated Compressed Air Dryers 5-6,000 scfm Refrigerated Compressed Air Dryers 5-6,000 scfm Refrigerated Non-Cycling Refrigerated Cycling Refrigerated High Temperature OWS - 210 Sullair Capabilities Sullair Leadership Since 1965, Sullair has been

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated Air Dryers Dual Control and Demand Manager Series 600-3000 scfm Energy Saving Refrigerated Dryers A Choice of Two Because compressed air demand fluctuates in some applications and is relatively

More information

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT GREAT LAKES AIR ANDARD ELECTRONIC DRAIN STANDARD ELECTRONIC 5 -YEAR WARRANTY 35-39 F PRESSURE DEWPOIN SS EXPANSION VALVE STANDARD ELECTRONIC DRAIN 35-39 F PRESSURE DEWPOINT GTX Series Thermal Xchange Cycling

More information