T8034C Heating/Cooling Thermostats

Size: px
Start display at page:

Download "T8034C Heating/Cooling Thermostats"

Transcription

1 T8034C Heating/Cooling Thermostats INSTALLATI INSTUCTIS APPLICATI These T8034C Thermostats control 4 to 30 Vac singlestage heating-cooling systems. An spdt mercury switch makes (H) to on temperature fall for heating, and (C) to on temperature rise for cooling. Integral switches control -- system operation and - or - fan operation. Heat anticipation is adjustable, 0.8A to.0a. See Fig.. Includes dual Celsius/Fahrenheit temperature scale. MECU NOTICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of properly. Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old control. MOUNTIN HOLE (THEMOSTAT TO ALL O OUTLET BOX) BIMETAL ELEMENT BEHIND SCALE..8.5 L O N.3.35 ADJUSTABLE INDICATO FAN MOUNTIN HOLE TEMPEATUE SETTIN LEVE M560 Fig.. Internal view of the T8034C. INSTALLATI hen Installing this Product. ead these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.. Check the ratings given in the Instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these Instructions. CAUTI Can cause electrical shock or equipment damage. Disconnect power supply before beginning installation. Location Locate the thermostat about 5 ft (.5m) above the floor on an inside wall in an area with good air circulation at average temperature. Do not mount the thermostat where it can be affected by: drafts or dead spots behind doors or in corners. hot or cold air from ducts. radiant heat from the sun, fireplaces or appliances. unheated (uncooled) areas such as outside walls behind the thermostats. This thermostat is a precision instrument and was carefully adjusted at the factory. Handle it carefully. Mounting and iring Disconnect power supply before beginning installation to prevent electrical shock or equipment damage. All wiring must comply with local codes and ordinances. The T8034C can be mounted directly on a wall or horizontal outlet box. Use Honeywell part no Horizontal allplate (beige) to cover mounting marks left by the old thermostat, or use Honeywell part no. 93A Mounting Plate Assembly (beige) to mount on vertical outlet box or to cover wall marks where larger plate is needed. Order the horizontal wallplate or mounting plate assembly separately. U.S. egistered Trademark Copyright 00 Honeywell All ights eserved X-XX UL

2 T8034C IN/IN THEMOSTATS If the 0058 Horizontal allplate is used, align the thermostat and wallplate (see Fig. ) and press firmly together until the wallplate snaps in place; then wire and mount the thermostat. If the 93A Mounting Plate Assembly is used, review the instructions provided with the assembly before wiring and mounting the thermostat. UP Heat Off Cool On FAN Auto Connect the wires to the terminals on the back of the thermostat. See Fig. 3. For internal schematic and typical hookup diagram, see Fig. 4 through emove the thermostat cover by pulling outward on the right edge of cover until it snaps free of the thermostat base. Carefully remove and discard the foam plastic shipping insert that protects the switch and bimetal assembly during shipping. 5. Set the adjustable heat anticipator indicator to match the current draw of the primary heating control (see Heat Anticipator Setting). 6. Push excess wire back through the hole and plug any opening with insulation to prevent drafts that may affect thermostat performance. 7. Loosely fasten the thermostat (with wallplate, if applicable) to the wall or outlet box with a screw through the left mounting hole. Adjust the thermostat so that it is approximately level and fasten the second screw through the right mounting hole. Do not tighten. 8. For optimum performance, level the thermostat using a spirit level or plumb line. Tighten the mounting screws. 9. eplace the thermostat cover. JUMPE M087 H Fig.. Mount the T8034C Thermostat on 0058 allplate. IMPOTANT An incorrectly leveled thermostat causes inaccurate temperature control. C To wire and mount thermostat:. In replacement applications, check the existing thermostat wires for cracked or frayed insulation. eplace any wires in poor condition. If the wire is plastered into the wall, make a hole next to the wires and loosen the wires so that they can be pushed back into the wall later.. In new installations, run wiring (if necessary) to the thermostat location. JUMPE NOT SUPPLIED ITH THEMOSTAT. M330 Fig. 3. hen using T8034C with H and C terminals in single transformer system, jumper H, C terminals. FAN C CTACTO L H ELA L POE SUPPL. POVIDE DISCNECT MEANS AND OVELOAD POTECTI AS EQUIED. JUMPE C, H TEMINALS FO SINLE TANSFOME. M4A Fig. 4. Internal schematic and typical hookup for T8034C in heating-cooling system with separate heating-cooling transformers or single transformer

3 T8034C IN/IN THEMOSTATS FAN L CTACTO ELA POE SUPPL. POVIDE DISCNECT MEANS AND OVELOAD POTECTI AS EQUIED. JUMPE - FO AS O OIL FOCED AM AI IN ITH CVENTIAL IN. JUMPE - FO CENTAL ELECTIC IN ITH CVENTIAL IN. IF JUMPE IS NOT CNECTED THEMOSTAT ILL NOT ENEIZE FAN IN POSITI. M034F Fig. 5. Internal schematic and typical hookup for T8034C in gas- or oil-fired or central electric heat systems. L FAN P O DEFOST ELA CHANEOVE ELA () ELA CTACTO CHANEOVE ELA () B POE SUPPL. POVIDE DISCNECT MEANS AND OVELOAD POTECTI AS EQUIED. M97 Fig. 6. Internal schematic and typical hookup for T8034C with terminal for defrost relay in heat pump system

4 T8034C IN/IN THEMOSTATS FAN O CHANEOVE ELA () L POE SUPPL. POVIDE DISCNECT MEANS AND OVELOAD POTECTI AS EQUIED. JUMPE - FO AS O OIL FOCED AM AI IN ITH CVENTIAL IN. JUMPE - FO CENTAL ELECTIC IN ITH CVENTIAL IN O SINLE STAE PUMP APPLICATIS. IF JUMPE IS NOT CNECTED, THEMOSTAT ITH NOT ENEIZE FAN IN POSITI. 3 JUMPE - FO SINLE STAE PUMP APPLICATIS. M33C 3 B ELA CHANEOVE ELA () ELA Fig. 7. Internal schematic and typical hookup for T8034C in single transformer heating-cooling system. TEMP FALL FAN L ELA CTACTO POE SUPPL. POVIDE DISCNECT MEANS AND OVELOAD POTECTI AS EQUIED M54 Fig. 8. Internal schematic and typical hookup for T8034C in single transformer heating-cooling systems

5 T8034C IN/IN THEMOSTATS 4 FAN ELA L 5 B O CHANEOVE ELA () CHANEOVE ELA () POE SUPPL. POVIDE DISCNECT MEANS AND OVELOAD POTECTI AS EQUIED. ELA M333 Fig. 9. Heat Pump iring for T8034C. SETTIN AND ADJUSTMENT System and Fan Switching The T8034C features and FAN switches for control of the heating-cooling and fan systems. The switch controls system operation as follows: : Only heating system operates. : Both heating and cooling systems are off. : Only cooling system operates. The FAN switch controls fan operation as follows: : In standard systems, fan operates in response to the thermostat in cooling; fan operates in response to the plenum fan control in heating. In heat pump or electric heat systems, the fan operates in response to the thermostat in heating and cooling. : The fan runs continuously. To switch positions, slide the lever to the desired position. Place the switch lever directly over the desired indicator mark for proper circuit operation. Heat Anticipator Setting IMPOTANT The T8034C Thermostat has an adjustable heat anticipator and operates properly L IF THE IS ADJUSTED TO MATCH THE CUENT DA OF THE PIMA C- TOL. Use this thermostat only on systems with current draws that fall within the range of the heat anticipator. Do not use this device on Powerpile (millivolt) systems. If the current rating is not available:. Turn off the power.. ire the thermostat, but do not mount it on the wall. 3. Connect an ammeter between the wire and terminal on the thermostat (in series with the primary control). 4. Prepare the system for operation. 5. Turn on the power. 6. Turn the system switch to heat. 7. Increase the thermostat setpoint as necessary to get the system operating. 8. ith the system operating through the ammeter, wait one minute, then read the ammeter. 9. Turn the system switch to, and turn off the power. 0. Adjust the heat anticipator to match the reading on the ammeter.. Disconnect the ammeter, reconnect the wire, and mount the thermostat. Continue with system checkout. The heat anticipator could require further adjustment for best performance. To lengthen the burner-on time, move the indicator in the direction of the longer arrows not more than one-half scale marking at a time. To shorten the burner-on time, move the indicator in the opposite direction. Most one-stage heating equipment is designed to operate at five to six cycles per hour, at 50 percent load conditions. hen using a T8034 Thermostat in heat pump systems, set the heat anticipator at 40 percent of the actual primary control current draw to reduce the cycling rate. Most heat pump systems should cycle -/ to 3 times per hour. A current rating is usually stamped in the nameplate of the primary control. Set the adjustable heat anticipator indicator to match the value given on the nameplate

6 T8034C IN/IN THEMOSTATS CHECKOUT CAUTI Can cause damage to heat anticipator. Do not check operation by shorting across terminals of system controls. IMPOTANT To assure accurate temperature control, do not touch or breathe on bimetal or thermometer. Heating ith system switch set at and fan switch at, move the temperature setting lever about 0 F (6 C) above the room temperature. In standard systems, the heating should start and the fan should start after a short delay. In heat pump or electric heat systems, both the heating and fan should start. Move the temperature setting lever about 0 F (6 C) below the room temperature. In standard systems, the heating should shut off and the fan should shut off after a short delay. In heat pump or electric heat systems, both the heating and fan should shut off. IN NOTE: CAUTI Can cause damage to compressor. Do not operate cooling if outdoor temperature is below 50 F (0 C). efer to manufacturer recommendations. To prevent compressor short cycling, some manufacturer equipment includes a minimum offtimer to provide a five-minute time delay before activating the compressor when the thermostat last turned the compressor off, or from when the system first received power. This delay protects the compressor. ith the system switch set at and fan switch at, move the temperature setting lever about 0 F (6 C) below the room temperature. Cooling and fan should start (see NOTE in IN section). Move the temperature setting lever about 0 F (6 C) above the room temperature. Cooling and fan should shut off. Fan ith the system switch set at, and the fan switch at, the fan should run continuously. Move the fan switch to. In standard systems, fan operation is controlled by the plenum fan control in heating and by the thermostat in cooling. In heat pump or electric heat systems, fan operation is controlled by the thermostat in heating and cooling. ecalibration These thermostats are calibrated at the factory and should not need recalibration. If the thermostat needs adjustment, first check for accurate leveling. To check calibration:. Move the temperature setting lever to the lower end of the temperature scale. System switch must be placed in the position. ait at least five minutes.. emove the thermostat cover. Move the setting lever until the switch just makes contact. The mercury in the switch rolls to the left end of the tube. 3. eplace the cover and wait five minutes for the cover and the thermostat to lose the heat gained from your hands. If the thermometer pointer and the setting lever indicator read approximately the same, no recalibration is needed. If recalibration is necessary:. Place the temperature setting lever at the same setting as the thermometer. emove the cover by pulling outward on right edge of cover until it snaps free of the thermostat base.. Insert 04994A Calibration rench (ordered separately) onto the hex nut under the coil. See Fig. 9. Hold the setting lever so it does not move and turn the wrench clockwise until the mercury rolls to the right end of the tube. emove the wrench and replace the cover. NOTE: To assure accurate temperature control, do not touch or breathe on bimetal or thermometer. 3. Move the setting lever to a low setting. ait at least five minutes for the temperature to stabilize. 4. Slowly move the setting lever until it reads the same as the thermometer. 5. emove the cover. Hold the setting lever so it does not move, reinsert the wrench and carefully turn counterclockwise until the mercury rolls to the left end of the tube, but no farther. 6. echeck the calibration. Set the thermostat system switch for the desired operation and replace the cover. COIL SH ITHOUT CALIBATI ENCH M044A Fig. 9. ecalibration procedure. Automation and Control Solutions Honeywell 985 Douglas Drive North olden Valley, MN 554 Automation and Control Solutions Honeywell Limited-Honeywell Limitée 35 Dynamic Drive oad Scarborough, Ontario MV 4Z9 Printed in U.S.A. on recycled paper containing at least 0% H. -0 post-consumer 6 paper fibers.

T834C Heating-Cooling Thermostat

T834C Heating-Cooling Thermostat M3375 M3375 TRADELINE T834C Heating-Cooling Thermostat Application T834C Thermostats control 4 to 30 Vac single-stage heating-cooling systems. See Table for specific models and applications. An spdt mercury

More information

T8400C and T8401C Electronic Thermostats

T8400C and T8401C Electronic Thermostats T8400 and T840 Electronic Thermostats INSTALLATION INSTUTIONS The T8400 and T840 Thermostats provide singlestage, non-programmable temperature control for 4V heating-cooling systems with manual changeover

More information

T8400C Universal Electronic Thermostats

T8400C Universal Electronic Thermostats T8400C Universal Electronic Thermostats INSTALLATIN INSTUCTINS APPLICATIN The T8400C Universal Thermostat provides single-stage, non-programmable temperature control for 24 Vac heating-cooling systems

More information

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B

More information

T8000C Programmable Thermostat

T8000C Programmable Thermostat T8000C Programmable Thermostat APPLICATIN The T8000C Thermostat provides single-stage, programmable temperature control for 24 Vac heating-cooling systems with manual changeover from heat to cool. Heating

More information

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell M3375 M3375 T874A-F Multistage Thermostats; Q674A- Subbases by Honeywell Installation Instructions for the Trained Service Technician Application The T874A-F Thermostats provide 4 to 30 Vac control for

More information

T874 Multistage Thermostat and Q674 Subbase

T874 Multistage Thermostat and Q674 Subbase SUPER TRADELINE T874 Multistage Thermostat and Q674 Subbase Application The T874D Thermostat and Q674E Subbase provide 4 to 30 Vac control of standard stage heating and stage cooling systems. The Y594D

More information

T874R Thermostats and Q674L Subbases

T874R Thermostats and Q674L Subbases T87 Thermostats and Q7L Subbases Installation Instructions for the Trained Service Technician. APPLICATI INSTALLATI INSTUCTIS The T87 Thermostat and Q7L Subbase provide to 0 Vac control of -stage heating

More information

T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase

T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase M75 M75 T8090A/Q68B Heating, ooling, and Heating-ooling Thermostat, allplate and Subbase SUPER TRADELINE Installation Instructions for the Trained Service Technician. Preparation heck thermostat and subbase

More information

T8400C Electronic Thermostat

T8400C Electronic Thermostat T8400 Electronic Thermostat INSTALLATION INSTUTIONS The T8400 provides single-stage, non-programmable temperature control for 24V heating-cooling systems with manual changeover from heat to cool. Heating

More information

T8411R Electronic Heat Pump Thermostat

T8411R Electronic Heat Pump Thermostat T84R Electronic Heat Pump Thermostat INSTALLATION INSTRUCTIONS The T84R Heat Pump Thermostat provides 24V control of two-stage heating and one-stage cooling heat pump system with manual changeover from

More information

T8112 Programmable Thermostat

T8112 Programmable Thermostat T8112 Programmable Thermostat FEATUES PODUCT DATA HEAT-OFF-COOL system switch. AUTO-ON fan switch. Separate programs for weekdays and weekends (5 day/2 day). Digital LCD display. Easy to program and install.

More information

T4398A,B High Performance Electric Heat Thermostats

T4398A,B High Performance Electric Heat Thermostats T498A,B High Performance Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides

More information

Y8196A (T8196A Thermostat/ Q682A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions

Y8196A (T8196A Thermostat/ Q682A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions M3375 M3375 89A (T89A Thermostat/ Q8A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions Preparation Check thermostat and subbase suitability for the heating,

More information

T4098A,B Deluxe Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats T4098A,B Deluxe Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides 2 F

More information

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats T8602C Chronotherm IV Deluxe mable Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8602 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling

More information

T8401C Electronic Thermostats

T8401C Electronic Thermostats T8401C Electronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8401C Thermostat provides single-stage, nonprogrammable temperature control for 24 Vac heating cooling systems with manual changeover

More information

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats T7200D,E Series 2000 Commercial Microelectronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T7200D,E Thermostats provide electronic control of 24 Vac commercial single-zone heating, ventilating

More information

Deluxe Programmable Heat Pump Thermostat T8611M

Deluxe Programmable Heat Pump Thermostat T8611M APPLICATION Deluxe mable Heat Pump Thermostat T8611M INSTALLATION INSTRUCTIONS The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models M75 M75 Installation Instructions Thermometer Scale Range: 45 o F to 85 o F [7 o C to 29 o C]. Electrical Ratings: 24 to 27 Vac. CT70A Heat Pump Thermostat Do-It-Yourself Models Your Honeywell Thermostat

More information

Deluxe Programmable Thermostats

Deluxe Programmable Thermostats Deluxe mable Thermostats T8602D INSTALLATION INSTRUCTIONS APPLICATION The T8602D IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling systems or 750 mv heating

More information

T8611M Deluxe Programmable Heat Pump Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats T8611M Deluxe mable Heat Pump Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

T8700B,C An Electronic Round Programmable Thermostat

T8700B,C An Electronic Round Programmable Thermostat B,C An Electronic ound Programmable Thermostat FEATUES PODUCT DATA APPLICATION C The Electronic ound Programmable Thermostats provide single-stage, programmable temperature control for 24V heating and/or

More information

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats T8600D Chronotherm IV Deluxe mable Thermostats APPLICATION INSTALLATION INSTRUCTIONS The T8600 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac singlestage heating and cooling

More information

L404A-D, F; L604A,L Pressuretrol Controllers

L404A-D, F; L604A,L Pressuretrol Controllers L404A-D, F; L604A,L Pressuretrol Controllers FEATUES PODUCT DATA APPLICATION L404 and L604 Pressuretrol Controllers are line voltage pressure controllers that provide operating control, automatic limit

More information

TCONT800AS11AA Touch Screen Programmable Comfort Control

TCONT800AS11AA Touch Screen Programmable Comfort Control TCONT800AS11AA Touch Screen Programmable Comfort Control 18-HD25D18-1 APPLICATION INSTALLATION INSTUCTIONS The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating

More information

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats T8624D Chronotherm IV Deluxe mable Multistage Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8624D Chronotherm IV Deluxe mable Multistage Thermostats provides electronic control of 24 Vac single-zone

More information

ASYSTAT625A Humidity Control

ASYSTAT625A Humidity Control ASYSTAT65A Humidity Control INSTALLE S GUIDE APPLICATION Humidity Control The humidity control provides automatic low voltage control of humidifiers in central heating and cooling equipment for both humidification

More information

T8195B/Q682B,C, Y8224A Heating or Cooling and Heating/Cooling New Construction Thermostat, Wallplate and Subbase

T8195B/Q682B,C, Y8224A Heating or Cooling and Heating/Cooling New Construction Thermostat, Wallplate and Subbase M3375 M3375 T895/Q68,, 84A eating or ooling and eating/ooling New onstruction Thermostat, allplate and Subbase Installation Instructions for the Trained Service Technician. Preparation heck thermostat

More information

ACONT800AS11AA Touch Screen Programmable Comfort Control

ACONT800AS11AA Touch Screen Programmable Comfort Control ACONT800AS11AA Touch Screen Programmable Comfort Control 11-HD02D8-3 APPLICATION INSTALLATION INSTUCTIONS The ACONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating and

More information

Home and Building Control Home and Building Control Helping You Control Your World

Home and Building Control Home and Building Control Helping You Control Your World M3375 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited/Honeywell Limitée 1985 Douglas Drive No. 740 Ellesmere Road Golden Valley, MN 55422

More information

TCONT800AS11AA Touch Screen Programmable Comfort Control

TCONT800AS11AA Touch Screen Programmable Comfort Control TCONT800AS11AA Touch Screen Programmable Comfort Control 18-HD25D18-3 APPLICATION INSTALLATION INSTUCTIONS The TCONT800AS11AA Programmable Comfort Control provides electronic control of 24 Vac heating

More information

CT500 Electronic Thermostat

CT500 Electronic Thermostat CT500 Electronic Thermostat OWNER'S GUIDE MERCURY NOTICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly.

More information

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat INSTALLATION INSTRUCTIONS APPLICATION The T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat provides electronic control of 24 Vac zoned heat pump

More information

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A Heating/Cooling Thermostat and Subbase Package T8196A/Q682A OWNER'S MANUAL M3375 Congratulations on your purchase of a Honeywell energy saving thermostat. The Honeywell name is your assurance of accurate

More information

Y594 (Multistage Thermostat Subbase) Package

Y594 (Multistage Thermostat Subbase) Package TADIN (Multistage Thermostat Subbase) Package APPIATI These and J combination packs are designed to meet the specific requirements of arrier heat pump equipment. The packs are designed for stage heat and

More information

T8400C, T8401C and T8424C,D Electronic Thermostats

T8400C, T8401C and T8424C,D Electronic Thermostats T8400, T840 and T844,D Electronic Thermostats PODUT DATA APPLIATION T8400 and T840 T844,D The T8400 and T840 Standard Electronic Thermostats provide single-stage, non-programmable temperature control for

More information

C554A Cadmium Sulfide Flame Detector

C554A Cadmium Sulfide Flame Detector C554A Cadmium Sulfide Flame Detector FEATURES PRODUCT DATA Cadmium sulfide sensing element provides faster response than bimetal sensors. On flame failure, the cad cell causes the oil primary control to

More information

W859F Economizer Control Packages

W859F Economizer Control Packages Economizer Control Packages 859F Economizer Control Packages are used with any Series 9 Modutrol IV Motor (M9XX) to modulate the outdoor and return air dampers for most economical operation of an economizer

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RDERS 1F58 Low Voltage Multi-Stage Heat PumpThermostat INSTALLATIN INSTRUCTINS perator: Save these instructions for future use FAILURE T READ AND FLLW ALL INSTRUCTINS CAREFULLY EFRE INSTALLIN R PERATIN

More information

T8132C Programmable Thermostats

T8132C Programmable Thermostats T832 Programmable Thermostats pplication The T832 Programmable Thermostat provides energy savings for heating and cooling applications. Separate programs can be set for weekdays and weekends. heck Table

More information

CT1500, CT1501, CT1502, CT1503

CT1500, CT1501, CT1502, CT1503 Timer Thermostat Fuel Saver Heating-Only Thermostat and Wallplate or Heating/Cooling Thermostat and Subbase Models CT1500, CT1501, CT1502, CT1503 Heat Only CT1500 Heat/Cool CT1501 Central Electric Heat/Cool

More information

TZ-3 TotalZone Zone Control Panel

TZ-3 TotalZone Zone Control Panel TZ-3 TotalZone Zone Control Panel FEATUES PODUCT DATA APPLICATION The TZ-3 TotalZone Zone Control Panel controls single-stage, multi-stage, conventional or heat pump heat/cool equipment. It controls 2

More information

TK-1001, 1101, 1201, 1301, 1601

TK-1001, 1101, 1201, 1301, 1601 TK-1001, 1101, 1201, 1301, 1601 Pneumatic Room Thermostats General Instructions DEVICE INFORMATION Identification Thermostats of this family may be easily identified by referring to the part number located

More information

T8112C,DElectronic ProgrammableThermostats

T8112C,DElectronic ProgrammableThermostats Honeywell T8112C,DElectronic ProgrammableThermostats APPLICATION The T8112C,D thermostats provide electronic programmable control for 24 to 30 Vac heating and cooling systems. @ RECYCLING NOTICE if this

More information

Q382A,B Pilot Burners

Q382A,B Pilot Burners Q382A,B Pilot Burners INSTALLATION INSTRUCTIONS APPLICATION The Q382A,B Pilot Burners provide main burner ignition for natural and LP gas-fired equipment. The design makes them ideal for use with any millivolt

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

The T6140A,B Remote Bulb Temperature Controller

The T6140A,B Remote Bulb Temperature Controller T640A,B Remote Bulb Temperature Controller The T640A,B Remote Bulb Temperature Controller is used as a unit mount temperature controller in electric heat, fan coil, room air conditioner applications, cold

More information

Q7300L Series 2000 Commercial Thermostat Subbases

Q7300L Series 2000 Commercial Thermostat Subbases Q700L Series 2000 Commercial hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700L hermostat Subbase is used with the 700D,F hermostat to provide electronic control of commercial 24 Vac single zone

More information

F150E Media Air Cleaner

F150E Media Air Cleaner whole-house air quality system FEATURES F150E Media Air Cleaner PRODUCT DATA APPLICATION F150E W8600A AIRWATCH W8600A AIRWATCH filter change indicator. High efficiency media filter captures particles as

More information

IS Series Pressure Sensing Switches

IS Series Pressure Sensing Switches IS Series Pressure Sensing Switches FEATURES INSTALLATION INSTRUCTIONS IS3 PRESSURE SWITCH APPLICATION IS2 PRESSURE SWITCH The IS Series of pressure sensing switches offers the same proven compression

More information

H1008A,D Automatic Humidity Controls

H1008A,D Automatic Humidity Controls H00A,D Automatic Humidity Controls FEATURES PRODUCT DATA The H00A,D provides automatic control for by-pass flow-through, powered flow-through, steam and drum humidifiers in central heating systems. The

More information

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay INSTALLATION INSTRUTIONS APPLIATION The Switching Relay provides intermediate switching of line- and low-voltage devices from a line- or low-voltage controller and is typically applied

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

CT2700 An Electronic Round Programmable Thermostat

CT2700 An Electronic Round Programmable Thermostat CT2700 An Electronic Round Programmable Thermostat USER S GUIDE MERCURY SWITCH TYPICAL LOCATION OF A MERCURY SWITCH IN A THERMOSTAT M064 RECYCLING THERMOSTAT If this thermostat is replacing a control that

More information

Q7300H Series 2000 Commercial Thermostat Subbases

Q7300H Series 2000 Commercial Thermostat Subbases Q700H Series 000 Commercial hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700H hermostat Subbases are used with 700F hermostats to provide electronic control of commercial Vac single or multistage

More information

Oil-Fired Furnace Single Stage Heat Pumps No- Auxiliary Heat. Electric Air Conditioning

Oil-Fired Furnace Single Stage Heat Pumps No- Auxiliary Heat. Electric Air Conditioning ES100 ROUND DIGITAL NON-PROGRAMMABLE BATTERY OPERATED THERMOSTAT The ES100 Digital Thermostat is designed to work on the following 24V systems. This Thermostat will not control multistage heat pumps or

More information

T8524 Deluxe Electronic Thermostat

T8524 Deluxe Electronic Thermostat T8524 Deluxe Electronic Thermostat PRODUCT DATA T8524 FEATURES AND BENEFITS APPLICATION The T8524 Deluxe Electronic Thermostat provides electronic control of 18 to 30 Vac multistage heating and cooling

More information

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat INSTALLATION INSTRUCTIONS APPLICATION The T7300F Thermostat provides electronic control of 24 Vac commercial single zone

More information

T8011R Programmable Heat Pump Thermostat

T8011R Programmable Heat Pump Thermostat T8011R Programmable Heat Pump Thermostat FEATURES PRODUCT DATA APPLICATION The T8011R Heat Pump Thermostat provides 24 Vac control of a two-stage heating and one-stage cooling heat pump system with manual

More information

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE 1 69-1557 Welcome to the world of comfort and energy savings with your new Honeywell programmable thermostat. Your new programmable thermostat

More information

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning CONTENTS Installation Instructions for Heating & Air Conditioning IF79 n- Programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

T8112C,D Electronic Programmable Thermostats

T8112C,D Electronic Programmable Thermostats T8112, Electronic Programmable Thermostats INSTLLTION INSTUTIONS PPLITION The T8112, thermostats provide electronic programmable control for 24 to 30 Vac heating and cooling systems. EYLING NOTIE If this

More information

TP970 Series CONVERTASTAT Kits

TP970 Series CONVERTASTAT Kits TP970 Series CONVERTASTAT Kits APPLICATION REPLACEMENT DATA Each CONVERTASTAT Kit includes a universal wall plate adapter, cover, and a TP970 Series Thermostat to replace various manufacturer s thermostats.

More information

HE360 Humidifier Installation Kit

HE360 Humidifier Installation Kit HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that

More information

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT CONTENTS Installation Instructions for Heating & Air Conditioning 1F79 n-programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

Q7100A,C,D Thermostat Subbases

Q7100A,C,D Thermostat Subbases Q700A,C, hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700 hermostat Subbases provide electronic control of commercial Vac single or multistage heat pump or conventional heating and cooling systems.

More information

Electronic Thermostat

Electronic Thermostat Set FAN Auto On Room SYSTEM Cool Off Heat M18535 Electronic Thermostat OWNER S GUIDE Em Ht Aux Ht Set Room FAN Auto On SYSTEM Cool Off Heat Em.Ht. M18539 1 69-1490 69-1490 Congratulations on the purchase

More information

TH8320U and TH8321U Touch Screen Programmable Thermostats

TH8320U and TH8321U Touch Screen Programmable Thermostats TH80U and TH8U Touch Screen Programmable Thermostats APPLIATION INSTALLATION INSTUTIONS The TH80U and TH8U Touch Screen Universal Programmable Thermostats provide electronic control of 4 Vac heating and

More information

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel. THE EEN Z NE Z EE THE NE N Sequence of Operation: The reen Zone Z-300-HPS is a residential / light commercial zone control system that allows a single HVA unit to have up to three separate zones. Each

More information

TK-1801, TK-1811 TK-1801, TKR-1811

TK-1801, TK-1811 TK-1801, TKR-1811 TK-1801, TK-1811 TK-1801, TKR-1811 Pneumatic Zero Energy Band Room Thermostats General Instructions APPLICATION For proportional control of pneumatically-operated sequenced heating and cooling valves and/or

More information

Installer s Guide ACONT200AN11AA 1 Heat (Gas, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 Wire Hookup

Installer s Guide ACONT200AN11AA 1 Heat (Gas, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 Wire Hookup 11-HD03D1-3 Available in French Canadian (FC) Installer s uide ACONT200AN11AA 1 Heat (as, Oil* or Elec) / 1 Cool Electronic Non-Programmable, 4 ire Hookup ALL phases of this installation must comply with

More information

HE120, HE160 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES T7A, T7A,B, TA,B, TB Digital Fan-Coil Thermostats XE/XE00 SERES FEATURES PRODUCT DATA Attractive modern styling with digital display makes the thermostat ideal for offices or hotels. Hotel card key input

More information

F200E Charged-Media Air Cleaner

F200E Charged-Media Air Cleaner whole-house air quality system F200E Charged-Media Air Cleaner PRODUCT DATA FEATURES APPLICATION The F200E Charged-Media Air Cleaner captures a significant amount of the air-borne particles from the air

More information

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE Weekday, Saturday and Sunday Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3550 Honeywell CT3550 PROGRAMMABLE THERMOSTAT OWNER S GUIDE Para pedir estas instrucciones

More information

tcu.z Commercial Programmable Thermostat Installation Instructions

tcu.z Commercial Programmable Thermostat Installation Instructions Application Mercury Notice Installation The tcu.z Commercial Programmable Thermostat controls 24-VAC commercial single-zone heating, ventilating, and air conditioning (HVAC) equipment. It consists of a

More information

F25F Media Air Cleaner

F25F Media Air Cleaner F25F Media Air Cleaner FEATURES PRODUCT DATA High efficiency media filter captures particles as small as 1.0 micron. Efficiency and arrestance ratings based on the American Society of Heating, Refrigerating

More information

TZ-4 TotalZone Zone Control Panel

TZ-4 TotalZone Zone Control Panel TZ-4 TotalZone Zone Control Panel FEATURES PRODUCT DATA APPLICATION The TZ-4 TotalZone Zone Control Panel controls single-stage, multi-stage, conventional or heat pump heat/cool equipment. It controls,

More information

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION TK-5001, 5101 TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Pneumatic Room Thermostats General Instructions GENERAL INFORMATION The pneumatic thermostats are used for proportional

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-ODES 1F89-11 Non-Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPEATION INSTUTIONS Operator: Save these instructions for future use! FAILUE TO EAD AND FOLLOW ALL INSTUTIONS

More information

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE Honeywell CT3611 PROGRAMMABLE THERMOSTAT Seven Day Programmable Heat Pump Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT3611 OWNER S GUIDE Para pedir estas instrucciones en español, llame

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

UV100E Ultraviolet Air Treatment System

UV100E Ultraviolet Air Treatment System UV100E Ultraviolet Air Treatment System OWNER S GUIDE U.S. Registered Trademark Copyright 2001 Honeywell Inc. All Rights Reserved 69-1442- 1 HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM WORKS When installed

More information

CR7075 Two-Stage Lighting Controller

CR7075 Two-Stage Lighting Controller CR707 Two-Stage Lighting Controller FEATURES PRODUCT DATA Light intensity threshold levels field-adjustable by user. Independent Time of Day (TOD) override inputs. Optimum start/stop of lighting loads.

More information

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

Honeywell CT8602 PROGRAMMABLE THERMOSTAT Honeywell CT8602 PROGRAMMABLE THERMOSTAT Seven Day Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Wallplate Model CT8602 OWNER S GUIDE Para obtener un documento con las instrucciones

More information

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax: SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart

More information

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON Install guide 8022 HEAT OOL AUTO ON ustomer Suppt: 888-515-2585 Visit our website www.ritetemp.biz Install guide 8022 aution Tools To avoid electrical shock and to prevent damage to the furnace, air conditioner,

More information

T8000C, T8001C,T8024D Programmable Thermostats

T8000C, T8001C,T8024D Programmable Thermostats T8000C, T800C,T804D Programmable Thermostats FEATUES PDUCT DATA APPLICATIN The T8000C, T800C and T804D Programmable Thermostats provide programmable temperature control for 4 Vac heating-cooling systems

More information

CT2800 Programmable Thermostat

CT2800 Programmable Thermostat CT2800 Programmable Thermostat INSTALLATION AND PROGRAMMING INSTRUCTIONS Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically

More information

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR PRODUCT DATA C7232A C7232B FEATURES Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! HITE-RODERS 1F97-51 7-Day Electronic Digital Thermostat INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLO ALL INSTRUCTIONS CAREFULL BEFORE INSTALLIN OR

More information

Commercial Touchscreen Thermostat

Commercial Touchscreen Thermostat 55,13M 1/27 Supersedes 12/25 Commercial Touchscreen Thermostat 25 Lennox Industries, Inc. Dallas, Texas, USA APPLICATION Page 1 INSTALLATION INSTRUCTIONS The Lennox Commercial Touchscreen Thermostat provides

More information

TC-5231 Series, TC-5232, & TC-5241 Series

TC-5231 Series, TC-5232, & TC-5241 Series TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air

More information

Must be installed by a trained, experienced technician

Must be installed by a trained, experienced technician Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8321097: For up to 3 Heat/2 Cool heat pump or up to 2 Heat/2 Cool conventional

More information

MagicStat CT3300 Programmable Thermostat

MagicStat CT3300 Programmable Thermostat MagicStat CT3300 Programmable Thermostat Installation and Programming Instructions Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model

More information

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards FEATURES PRODUCT DATA TG509 TG511D TG510A TG512B Available in four sizes: mini, small, medium and large, to fit virtually all thermostats.

More information