62DA,DB,DC,DD,DE,DF07-38
|
|
- Daniel Golden
- 6 years ago
- Views:
Transcription
1 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New York Form 62D-3SB Replaces: 62D-2SB Printed in U.S.A Catalog No
2 Date: Supersedes: 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT 62DA,DB,DC,DD, DE,DF Rev.: -3SB JOB NAME: LOCATION: BUYER: BUYER P.O. # CARRIER # UNIT NUMBER: MODEL NUMBER: PERFORMANCE DATA CERTIFIED BY: DATE: DESCRIPTION All Carrier 62DA, DB, DC, DD, DE, DF dedicated outdoor air products are pre-wired, charged with R-10A, and tested in both cooling and heating modes at the factory. All 62DA, DB, DC, DD, DE,DF units feature an industrial grade cabinet with fully hinged access panels. Superior supply fan performance with up to 3. in. wg external static pressure is standard. The 62D Series units are available in dedicated vertical or horizontal supply configurations. The 62DC,DD,DE,DF units are also available with an energy recovery wheel or exhaust. A wide variety of heating options are available. All 62D Series units come standard with microprocessor control. PERFORMANCE FEATURES Puron HFC refrigerant (R-10A). High-efficiency scroll compressors. Thermostatic expansion valve (TXV) refrigerant metering device for each circuit. Two-stage cooling on sizes 07, 08, 09 units, three or more stages on sizes 12 to 38. Hot gas bypass. Cooling operation range up to 11 F ambient and down to 3 F ambient. 2-volt control circuit. Rubber fan vibration isolators. Double wall design. Sloped, insulated, stainless steel condensate pan. Two-inch disposable-type air filters (optional -in. available). Fixed speed belt-type blower drive. High-efficiency motors meet EISA ( HP and larger). Two-position outside-air damper is standard, on 100% OA units capable of admitting 100% outdoor air during fan operation, closed when the fan is off. Modulating economizer is standard on recirculating units. Rated in accordance with AHRI Standard 210 or 0. Tested in accordance with UL Standard 199. Listed by ETL and ETL, Canada. Microprocessor control with: Occupancy schedule Password protection Service diagnostics Alarms and alarm history Short-cycle compressor protection Support of communication with BACnet* and Modbus protocols Remote start/stop capability STANDARD UNIT FEATURES MAINTENANCE FEATURES Large hinged service access doors. Slide out fan system. INSTALLATION FEATURES Single point electrical service entry, through unit bottom or side. Rigging openings in base rail. RELIABILITY FEATURES Dual electrically and mechanically independent refrigeration circuits (Sizes 12 to 38). Crankcase heaters are standard on all models. Compressor protection includes high and low pressure switches. Freeze protection. Liquid line filter driers. Circuit breaker protection for all power components. Cabinet made of pre-painted, galvanized steel with baked enamel finish, which meets ASTM B117 salt spray resistance. Condenser-fan motors are open drip proof, with internal protection. GAS HEATING SYSTEM FEATURES Stainless steel heat exchanger. Induced draft combination for safety and reliability. Two-stage gas valves with redundant 100% shutoff. Direct spark ignition. STANDARD WARRANTY Standard one-year warranty. Five-year non pro-rated warranty on heat exchanger. * Sponsored by ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers). Registered trademark of Schneider Electric. 2
3 PERFORMANCE DATA Supply Air cfm ESP Exhaust Air cfm ESP COOLING COIL Entering Air db F wb F Total Capacity Btuh Sensible Capacity Btuh Latent Capacity Btuh Leaving Air db F wb F Liquid Subcooling Circuits Liquid Subcooling Rise (Max) F Leaving Subcooling Coil Temperature db F Hot Gas Reheat Circuits Hot Gas Reheat Capacity Btuh Hot Gas Reheat Rise (Max) F Hot Gas Reheat Leaving Air Temperature db F Unit Power Consumption kw Unit Efficiency EER OPTIONAL ENERGY CONSERVATION WHEEL SUMMER CONDITIONS Entering Air db F wb F Return Air db F wb F Total Capacity Btuh Sensible Capacity Btuh WINTER CONDITIONS Entering Air db F wb F Return Air db F wb F Total Capacity Btuh Sensible Capacity Btuh OPTIONAL GAS HEAT Input Btuh Output Btuh Total Temperature Rise F Entering-Air Temperature F Leaving-Air Temperature F OPTIONAL ELECTRIC HEAT Total Heating Capacity kw Heat Output Btuh Total Temperature Rise F Entering-Air Temperature F Leaving-Air Temperature F OPTIONAL HOT WATER HEATING COIL Fluid Type Flow Gpm Total Heating Capacity Btuh Entering Water Temperature F Leaving Water Temperature F Total Temperature Rise F Entering-Air Temperature F Leaving-Air Temperature F OPTIONAL STEAM HEATING COIL Steam Pressure psi Condensate Flow lb/hr Total Heating Capacity Btuh Total Temperature Rise F Entering-Air Temperature F Leaving-Air Temperature F ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection SUBMITTAL DATA Job Name Architect Engineer Contractor Unit Designation 3
4 OPTIONS AND ACCESSORIES Gas Heat Gas Heat with Space Temperature Override Electric Heat Hot Water Heating Coil Steam Heating Coil Energy Conservation Wheel Energy Conservation Wheel with VFD Defrost Control Energy Conservation Wheel with Return Air Bypass Filter Status Switch Phase/Voltage Monitor with Energy Management Relay Firestat VFD on IFM VFD on PE motor Convenience Outlet Disconnect Switch FACTORY-INSTALLED OPTIONS Hot Gas Reheat Coil Liquid Subcooling Coil Coated Coils -in. MERV 8 Filters -in. MERV 11 Filters -in. MERV 1 Filters 2-in. Metal Mesh Filters Backward Inclined Supply Fan Forward Curved Exhaust Fan Backward Curve Fan Airfoil Fan LonWorks* Communication Digital Compressor Return Air Smoke Detector CO 2 Sensor Roof Curb (1 in.) Roof Curb (2 in.) FIELD-INSTALLED ACCESSORIES BACview Handheld Keypad Display OTHER SPECIAL ITEMS * Registered trademark of Echelon Corporation.
5 UNIT DIMENSION PRINT 62DA,DB07-09 STANDARD UNIT 38 1/2 3 1/2 1 TYP TOP VIEW 7 1/2 SUPPLY 6 1/2 1 1/2 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE POWER THROUGH THE CURB SIDE VIEW (HORIZONTAL SUPPLY) /2 39 3/ SUPPLY FAN /2 82 1/2 97 1/8 a / 1 /8 8 CONTROL PANEL FILTER ACCESS FRONT VIEW CONDENSATE DRAIN PAN OUTSIDE AIR INTAKE HOOD NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches.
6 UNIT DIMENSION PRINT 62DC,DD,DE,DF07-09 UNIT WITH OPTIONAL EXHAUST 38 1/2 1 TYP /2 3 1/ SUPPLY 3 1/2 30 1/ 20 RETURN TOP VIEW 1 1/2 6 1/2 1 1/2 9 7/8 POWER THROUGH THE CURB 39 3/ 2 1/ / 82 1/2 2 1/8 SIDE VIEW (HORIZONTAL SUPPLY) SUPPLY FAN CONTROL PANEL FILTER ACCESS 32 FRONT VIEW /2 62 OUTSIDE AIR INTAKE HOOD 38 1/ 8 CONDENSATE DRAIN PAN a62-6 NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. 6
7 UNIT DIMENSION PRINT 62DC,DD,DE,DF07-09 UNIT WITH OPTIONAL ENERGY CONSERVATION WHEEL 38 1/2 3 1/2 3 1/2 96 1TYP / /8 T OP VIEW 7 1/2 SUPPLY RETURN 6 1/2 1 1/2 1 1/2 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE POWER THROUGH THE CURB SIDE VIEW (HORIZONTAL SUPPLY) /2 39 3/ S UPPLY FAN /2 10 / / a /8 2 1/8 CONTROL PANEL 38 1/ CONDENSATE 8 DRAIN PAN FILTER ACCESS F RONT VIEW OUTSIDE AIR INTAKE HOOD EXHAUST NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. 7
8 UNIT DIMENSION PRINT 62DA,DB12-20 STANDARD UNIT 38 1/2 1 TYP. TOP VIEW / /2 SUPPLY 1 1/2 6 1/2 POWER THROUGH THE CURB 39 3/ 2 1/2 82 1/2 97 1/8 1 /8 SIDE VIEW (HORIZONTAL SUPPLY) 32 SUPPLY FAN CONTROL PANEL FILTER ACCESS FRONT VIEW /2 OUTSIDE AIR INTAKE HOOD 38 1/ 8 CONDENSATE DRAIN PAN a62-67 NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. 8
9 UNIT DIMENSION PRINT 62DC,DD,DE,DF12-20 UNIT WITH OPTIONAL EXHAUST 38 1/2 1 TYP / / / 20 SUPPLY RETURN 3 1/2 TOP VIEW 1 1/2 6 1/2 1 1/2 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE POWER THROUGH THE CURB SIDE VIEW (HORIZONTAL SUPPLY) /2 39 3/ 2 1/2 82 1/ / SUPPLY FAN 62 a /8 2 1/8 CONTROL PANEL 38 1/ CONDENSATE 8 DRAIN PAN FILTER ACCESS FRONT VIEW OUTSIDE AIR INTAKE HOOD EXHAUST NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. 9
10 UNIT DIMENSION PRINT 62DC,DD,DE,DF12-20 UNIT WITH OPTIONAL ENERGY CONSERVATION WHEEL 38 1/ TYP /2 3 1/ / /8 TOP VIEW 7 1/2 SUPPLY RETURN 1 1/2 6 1/2 1 1/2 3/8 39 3/ 2 1/2 9 7/8 POWER THROUGH THE CURB 10 /8 2 1/ / SIDE VIEW (HORIZONTAL SUPPLY) SUPPLY FAN CONTROL PANEL FILTER ACCESS 32 FRONT VIEW /2 62 OUTSIDE AIR INTAKE HOOD 38 1/ 8 CONDENSATE DRAIN PAN EXHAUST NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. a
11 UNIT DIMENSION PRINT 62DA,DB22-38 STANDARD UNIT TOP VIEW 33 3/ 1 TYP. 2 13/16 96 SUPPLY 62 1/ 10 7/ /8 6 1/2 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE POWER THROUGH THE CURB SIDE VIEW (HORIZONTAL SUPPLY) 3 1/2 30 1/2 0 1/2 1/2 1/2 18 1/2 a62-70 SUPPLY FAN / / /2 CONTROL PANEL FILTER ACCESS CONDENSATE DRAIN PAN FRONT VIEW OUTSIDE AIR INTAKE HOOD NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. 11
12 UNIT DIMENSION PRINT 62DC,DD,DE,DF22-38 UNIT WITH OPTIONAL EXHAUST 1 TYP. 33 3/ / 10 7/8 2 7/8 1/ /16 2 SUPPLY RETURN / /2 7/8 TOP VIEW POWER THROUGH THE CURB 1 3/8 2 1/ 112 1/2 16 3/ 3 1/ SIDE VIEW (HORIZONTAL SUPPLY) SUPPLY FAN CONTROL PANEL FILTER ACCESS 3 1/2 OUTSIDE AIR INTAKE HOOD 30 1/2 0 1/2 18 1/2 83 FRONT VIEW 1/2 1/2 62 /8 8 CONDENSATE DRAIN PAN EXHAUST NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. a
13 UNIT DIMENSION PRINT 62DC,DD,DE,DF22-38 UNIT WITH OPTIONAL ENERGY CONSERVATION WHEEL 33 3/ 1 TYP / 2 13/16 1/ /8 30 SUPPLY 2 1/ TOP VIEW CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE SIDE VIEW (HORIZONTAL SUPPLY) 3 1/2 POWER THROUGH THE CURB 0 1/2 30 1/2 1/2 1/2 18 1/2 A62-72 SUPPLY FAN /2 63 1/ /8 CONTROL PANEL 3 1/ 170 3/ 62 /8 RETURN 7/ /8 3 3/16 FILTER ACCESS CONDENSATE DRAIN PAN ENERGY RECOVERY WHEEL OUTSIDE AIR INTAKE HOOD FRONT VIEW EXHAUST NOTES: 1. Carrier recommends a minimum of 2 to -in. of service clearance on all sides of unit except for the control panel side, which should have at least 8-in. clearance. Top should be unobstructed. 2. Dimensions are in inches. 13
14 ACCESSORY DIMENSION PRINT 62DA,DB,DC,DD,DE,DF07-20 UNITS 1-in. ACCESSORY ROOF CURB (FULLY ASSEMBLED) 8 1/2 EQUIPMENT RAIL SUPPORT (REFERENCE DIMENSIONS) EQUIPMENT RAIL SUPPORT 2 TYP. 37 3/ SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES 79 REF /32 0 3/32 2 1" FIBERGLASS INSULATION SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES 6 1/2 16 1/2 1" FIBERGLASS INSULATION ON BOTH SIDES. 1" FIBERGLASS INSULATION 2 1/ TYP. 1 NOTE: Dimensions are in inches. a in. ACCESSORY ROOF CURB (FULLY ASSEMBLED) 18 1/2 EQUIPMENT RAIL SUPPORT 2 TYP. 79 REF. 37 3/ INSULATED SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES EQUIPMENT RAIL SUPPORT 1" FIBERGLASS INSULATION /32 0 3/32 2 INSULATED SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES 6 1/2 16 1/2 1" FIBERGLASS INSULATION 2 1/ TYP. 1" FIBERGLASS INSULATION ON BOTH SIDES. 2 NOTE: Dimensions are in inches. 1
15 ACCESSORY DIMENSION PRINT 62DA,DB,DC,DD,DE,DF07-20 UNITS 1-in. ACCESSORY ROOF CURB (FIELD ASSEMBLED) Curb End Utility Channel Gasket Nail Counter Flashing Return 20 1/2" 1/2" Curb Side Rigid Insulation Roofing Felt Cant Strip 7 3/" 2 1/2" Supply 0 1/8" CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE a62-9 Rigid Insulation A30-3 Gasket Nail Roofing Material Equipment Support (Screw 2 Parts Together) 1 3/" 2-in. ACCESSORY ROOF CURB (FIELD ASSEMBLED) Counter Flashing Roofing Felt Cant Strip Roofing Material Return Equipment Support (Screw 2 Parts Together) 20 1/2" 7 3/" Gasket NOTE: Dimensions are in inches. Curb End 1/2" 1 3/" 2 1/2" Supply Utility Channel Curb Side 0 1/8" Gasket NOTE: Dimensions are in inches. 1
16 ACCESSORY DIMENSION PRINT 62DA,DB,DC,DD,DE,DF22-38 UNITS 1-in. ACCESSORY ROOF CURB (FULLY ASSEMBLED) EQUIPMENT RAIL SUPPORT 8 1/2 2 TYP REF. EQUIPMENT RAIL SUPPORT 1" FIBERGLASS INSULATION INSULATED SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES 8 13/16 13/ / /2 38 1/2 1" FIBERGLASS INSULATION ON BOTH SIDES. 1" FIBERGLASS INSULATION 2 1/ TYP. 1 NOTE: Dimensions are in inches. a in. ACCESSORY ROOF CURB (FULLY ASSEMBLED) 18 1/2 EQUIPMENT RAIL SUPPORT 2 TYP REF. INSULATED SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES EQUIPMENT RAIL SUPPORT 8 13/16 13/16 8 1" FIBERGLASS INSULATION INSULATED SOLID BOTTOM SPOT WELDED EVERY 6" ALL FOUR SIDES 6 7/ /2 38 1/2 1" FIBERGLASS INSULATION 1" FIBERGLASS INSULATION ON BOTH SIDES / TYP. NOTE: Dimensions are in inches. 16
17 ACCESSORY DIMENSION PRINT 62DA,DB,DC,DD,DE,DF22-38 UNITS 1-in. ACCESSORY ROOF CURB (FIELD ASSEMBLED) Return 2 1/2" Utility Channel Curb Side Gasket Nail Counter Flashing 10 3/" Supply 38 1/2" 7/8" Rigid Insulation Roofing Felt Cant Strip Roofing Material 37" Equipment Support (Screw 2 Parts Together) Gasket CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE a62-0 Equipment Support (Screw 2 Parts Together) A62- Return 2-in. ACCESSORY ROOF CURB (FIELD ASSEMBLED) 10 3/" 2 1/2" 37" Utility Channel Supply 38 1/2" Gasket Curb Side 7/8" Rigid Insulation NOTE: Dimensions are in inches. Gasket Nail Counter Flashing Roofing Felt Cant Strip Roofing Material NOTE: Dimensions are in inches. 17
18
19
20
Product Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel
Product Data 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial
More informationProduct Data. Features/Benefits. 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel
Product Data 62DA,DB,DC,DD,DE,DF07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial
More informationProduct Data. Features/Benefits. 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy Wheel. 6 to 35 Nominal Tons
Product Data 62DA,DB,DC,DD07-38 Dedicated Vertical or Horizontal Outdoor Air Unit with Optional Energy heel 6 to 35 Nominal Tons a62-393 a62-394 a62-395 62D07-09 62D12-20 Carrier s 62D Series commercial
More information48PGD/E/F/L/M/N PG20-28
48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More information48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION
More informationWeathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More information50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT
50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More information48TM GAS HEATING/ELECTRIC COOLING UNITS
48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION
More information48TF GAS HEATING/ ELECTRIC COOLING UNITS
48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More information48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
-3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationSubmittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat
SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS
WeatherExpert R Series Ultra High---Efficiency Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 07 --- 12 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION
More informationHEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS
HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, 300 15, 18, 20, and 25 NOMINAL TONS COMMERCIAL ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS ELECTRIC HEATING/ELECTRIC COOLING UNITS
More information48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS
48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationR7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units
TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low
More informationDCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
More informationDCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h
Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling
More informationSubmittal Data Performance Data Electrical Data
ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:
More informationTHE ULTIMATE ROOFTOP SOLUTION
Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationMaverick II Commercial Rooftop Systems 15 to 75 tons
Maverick II Commercial Rooftop Systems 15 to 75 tons Maverick II Commercial Rooftop Systems System performance and reliability make Maverick II commercial packaged rooftop systems the ideal solution for
More informationTHE RIGHT SPEC. RIGHT NOW.
THE RIGHT SPEC. RIGHT NOW. 6-12.5 TONS R7DA Gas/Electric Packaged DOAS System MADE FOR THOSE WHO RESPECT THE SPEC. Reznor light commercial packaged rooftops are highly configurable at the factory, so consultant
More informationDCG Commercial. Submittal Data Form
DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons
More information30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz
30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB
More informationSUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer
SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,
More informationDSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER
DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard
More informationBARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide
BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner
More informationRooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating
Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000
More informationEnergy Recovery with Cooling and Heating Model ERCH
Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,
More informationWALL-MOUNT HEAT PUMPS - (60HZ)
WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling
More informationDCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant
More informationH3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog
H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...
More informationSubmittal Summary Page
ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged
More informationSubmittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES
180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
DTC Series 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER Cooling Capacity: 35,600 60,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation
More informationBARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide
BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationProduct Data. Fig. 1 - Unit 50VR -A
50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged
More informationADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements
ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The
More informationMulti-Path RTU-TYPE 2
ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 2 (RTU1) CESMPU025RHVAV2 Date: February 17, 201 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV2 Unit features include: 25 Ton MultiPath
More informationProduct Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons
Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units
More informationRuud Commercial Achiever Series Package Gas Electric Unit
Package Gas Electric Ruud Commercial Achiever Series Package Gas Electric Unit RKPN- 14 SEER Series RKQN- 15 SEER Series Nominal Sizes 3-5 Tons [10.6-17.6 kw] (15 SEER/12.0 EER AND ABOVE ONLY) Proper sizing
More informationRT-OA TM Rooftop Outdoor-Air (DOAS)
RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...!
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationGREEN REFRIGERANT R-410A
WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationSECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS
SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the
More informationStanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT
SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationProduct Data. Fig. 1 - Unit 50VG -A
50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged
More informationRoofPak Applied Rooftop Systems
RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution
More informationRooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationCLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS
7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationThe ultimate fresh air solution.
Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged
More informationDirect Gas-Fired Make-Up Air Models DG and DGX
Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5
More informationBARD MANUFACTURING COMPANY, INC. W18AA-W72AB
BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install
More informationRN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More information50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron
50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product
More informationPACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationWall Mounted Air Conditioners with Gas Heat Models AVGA
PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety
More informationShelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified
Shelf Units 2, 3, and 4 ton R-407C ISO 9001 Certified the pioneer and builder of the most complete line of precision cooling equipment Data Aire s first precision cooling system was developed by data processing
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More informationProduct Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving
Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE
More informationSECTION (15733) - DEDICATED OUTDOOR AIR UNITS
PART 1 GENERAL 1.01 SUMMARY SECTION 23 74 33 (15733) - DEDICATED OUTDOOR AIR UNITS A. Section Includes: 1. Dedicated Outdoor-Air Units with Energy Recovery B. Related Sections: 1.02 REFERENCES 1. Section
More informationData Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified
Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most
More informationTHE WALL-MOUNT QUIET CLIMATE HEAT PUMPS
THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationTAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS
SUBMITTAL ***FOR APPROVAL*** TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS Project 66 Orland Square Dr. Landlord Renovations Location Orland Park,
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationFEATURES AND BENEFITS
FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory
More informationALL PRODUCTS BROCHURE
ALL PRODUCTS BROCHURE www.aaon.com d e d i c at i o n t o cust o m e r service since the founding of aaon in 1988, we have maintained our commitment to design, develop, manufacture and deliver heating
More informationGuide Specifications PART 1 GENERAL 1.01 SUMMARY
Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control
More information