IS Series Pressure Sensing Switches

Size: px
Start display at page:

Download "IS Series Pressure Sensing Switches"

Transcription

1 IS Series Pressure Sensing Switches FEATURES INSTALLATION INSTRUCTIONS IS3 PRESSURE SWITCH APPLICATION IS2 PRESSURE SWITCH The IS Series of pressure sensing switches offers the same proven compression spring and precision snap acting electrical switch as the other Honeywell popular and widely used current models. The IS Series is designed specifically to yield narrow switch differentials (the difference between on and off actuation points) as well as to hold tight setpoint tolerances throughout a wide temperature range. The IS Series has also added various integrated mounting methods, which, in turn, can be augmented with individualized brackets for applications requiring unique mounting configurations. The IS Series replaces older Honeywell and Tridelta PPS10000 and most 4000, 5000, 6000 and 7000 Series switches. Typical applications include detecting blockage in gas combustion system appliances (furnaces, fireplaces, commercial cooking appliances, water heaters, boilers, process dryers, etc.); detecting condensate drain blockage and fluid buildup; draft inducer verification; proving fan operation; proving a blocked filter with change in differential pressure; monitoring static pressure; sensing increase/decrease in system pressure; proving air across heating elements; detecting ice buildup in cooling coils; managing air in VAV systems; detecting web breaks on printing, coating or other web processes. Standard Features Low pressure sensitivity. Setpoint range of 0.10 in. wc (2.5 mm wc) to 5.0 in. wc (127 mm wc) [IS2]; 0.04 in. wc (1.0 mm wc) to 5.0 in. wc (127 mm wc)[is3]. Integrated sampling line connectors for 1/4 in. inside diameter (ID) tubing. Sample line connectors can be positioned at 15-degree increments. Color-coded pressure ports. Integrated screw bosses for mounting. Integrated snap switches. Integrated bleed holes. Bar-coded labeling. Optional Features Integrated mounting tabs. Data Matrix. L-shaped or half-strap brackets. 1/4 in. or 3/16 in. mixed or dedicated terminals. Flow restricting orifices to dampen pressure surges. Sample line connectors can be positioned on the flat surface or the standard perimeter locations. 3/16 in. fitting (IS2 only). Gold contacts for low electrical loads. Custom brackets for single (IS) and dual (BA) switch models. U.S. Registered Trademark Copyright 2002 Honeywell All Rights Reserved

2 SPECIFICATIONS Electrical Ratings: Spdt, Spst electrical load: 1/ to 277 Vac. 28 VA pilot 24 Vac. 125 VA pilot 120 Vac. Spst electrical load: 5A 120 to 277 Vac (IS2). Switching: Spst, spdt. Electrical Connectors: 1/4 in. x or 3/16 in. x (Optional: 3/16 in. x ) Overpressure rating: 3 to 14 in. wc. Ambient Temperature Range: -40 F to +190 F (-40 C to +88 C). Sample Line: Black positive; grey negative. 1/4 in. O.D. for use with 3/16 in. or 1/4 in. I.D. tubing; optional 3/16 in. O.D. (IS2 only.) Sample Medium: Air. Dimensions: For typical dimensions, see Fig. 1 through 10. Mounting Position: Diaphragm must be vertical (horizontal optional). Materials: Diaphragm: Post-cured silicone. Housing: Glass-filled poly. Product Life: Mechanical: 1,000,000 operations. Electrical: 250,000 operations. Approvals: Underwriters Laboratories Inc. Approved: MP2168. Canadian Underwriter Laboratories Inc. Approved: MP2168. CE Approval: Pending. Accessories: 27517BM L-Bracket (IS2) BM 1/2 Strap Bracket (IS2) BM L-Bracket (IS3) BM 1/2 Strap (IS3). 3-7/16 (87) 1-25/32 (45) 3-5/32 (80) 1-3/8 (35) 2-17/32 (64) 3-1/16 (78) 1-7/32 (31) 2-3/16 (56) 3-7/8 (82) 1/16 (2) 1/16 (2) 11/16 (17) M21001 Fig. 1. Dimensions of foot-mounted IS2 Pressure Sensing Switch in in. (mm). Differential model shown. 1-25/32 (45) 1-3/8 (35) 2-17/32 (64) 1-7/32 (31) 2-3/16 (56) BLEED HOLE SCREW BOSSES (0.120 x 0.38 DEEP) 1/16 (2) 1/16 (2) 11/16 (17) 3-7/8 (82) M21032B Fig. 2. Dimensions of IS2 Pressure Sensing Switch (without mounting feet or brackets) in in. (mm). Differential model shown

3 2-17/32 (64) 2-5/32 (55) 1-31/32 (50) 1/4 (6) 3-13/32 (86) 3-7/32 (82) 1-11/32 13/16 (34) 13/16 1-5/8 (42) 11/16 (17) M21002 Fig. 3. Dimensions of L-bracket mounted IS2 Pressure Sensing Switch in in. (mm). Differential model shown. (Bracket can be placed on switch pan, as shown, or on mounting pan.) 2-17/32 (64) 1-5/8 (42) 1 (25) 1/2 (13) 1-15/16 (49) 1-3/8 (35) 3-3/4 (95) 1-29/32 (49) 13/32 (10) M21003 Fig. 4. Dimensions of Half-Strap bracket mounted IS2 Pressure Sensing Switch in in. (mm). Negative pressure model shown. 2-3/4 (70) 4 (102) 2-17/32 (64) 7/8 (22) 43/64 (17) 1-11/32 13/16 (34) 1-5/8 (42) 13/16 M21004 Fig. 5. Dimensions of typical combination-mounting of IS2 Pressure Sensing Switch in in. (mm). BA2 model shown

4 2-9/16 (65) 1-3/32 (28) 7/16 (11) 11/16 (18) 3-1/8 (79) 7-21/32 (195) 2-5/8 (67) M /32 (64) Fig. 6. Dimensions of custom side-by-side IS2 Pressure Sensing Switches in in. (mm). BA2 model shown. 1-31/32 (50) 31/32 (25) BRACKET MOUNTING SCREW 25/32 2 (51) 1-19/32 (40) 3-9/32 (83) 2-29/32 (74) COMMON 4-5/16 (110) 2-9/32 (58) NORMALLY OPEN M20693 Fig. 7. Dimensions of IS3 Pressure Sensing Switch in in. (mm). L Bracket model shown. Negative pressure model shown

5 1/16 (2) 4-3/16 (107) 3-13/16 (97) 1-31/32 (50) 31/32 (25) 2 (51) 1-19/32 (40) 3-9/32 (83) 2-29/32 (74) 3-15/16 (100) 2-9/32 (58) M20694 Fig. 8. Dimensions of IS3 Pressure Sensing Switch in in. (mm). Foot-mounted model shown. Negative pressure model shown. 1-31/32 (50) 31/32 (25) 2 5/32 (64) 2 (51) 1-19/32 (41) 3-9/32 (83) 2-29/32 (74) 1/2 1-21/32 1 (13) (42) (25) 3-15/16 (100) 2-9/32 (58) 3/16 (5) 1-3/4 (44) 13/32 (10) M20695A Fig. 9. Dimensions of IS3 Pressure Sensing Switch in in. (mm). Half-strap bracket model shown. Differential model shown. INSTALLATION When Installing This Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. This control must be installed in accordance with the rules in force. 2. Check ratings and descriptions given in the Specifications to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is completed, check out product operation as provided in the instructions. WARNING Electrical Shock Hazard or Explosion Hazard. Can cause severe injury, death or property damage. 1. Disconnect power before installation. More than one disconnect may be involved. 2. Turn off all fuel sources before installation. 3. Follow all installation and checkout procedures for safe installation

6 Mounting To maintain the operating setpoint, the switch must be mounted with the diaphragm in a vertical position. See Fig. 10. If the device is supplied with inlet orifice diameter less than in. (0.7 mm), the installer must protect the orifice against clogging by a suitable means. An external filter capable of removing particulates greater than 0.02 in. (0.5 mm) is acceptable. NORMALLY CLOSED (N.C.) NEGATIVE CONNECTION POSITIVE CONNECTION NORMALLY OPEN (N.O.) Condensation Products of combustion generally contain a large quantity of vapor and generate condensation within the device as it cools. Condensate in the tubing or within the body of the IS Series switch can cause pressure control point offset. Condensate can also damage metal parts of the device making replacement necessary. Weatherproofing The IS Series Pressure Sensing Switches are not weather proof. To provide weatherproofing, install the switch in a NEMA 4 container. Pressure Line Connections Use of flexible or semi-flexible non-silicone tubing is recommended. IMPORTANT Do not force terminal connections. See Fig. 11. MOUNTING BRACKET COMMON M20696 Fig. 10. IS-2/IS-3 Switch, vertically mounted. NOTE: To mount using the built-in feet (Fig. 10), use No. 8 or No. 10 screws with a maximum torque of 15 in. lb. Mounting Recommendations 1. Mount with pressure connectors facing down. 2. Use No x 0.38 Type BT self-tapping screws for mounting of brackets or use of integrated screw bosses (maximum torque of 12 in.-lb). 3. Provide condensate draining by sloping tubing. IMPORTANT Do not locate in an area where temperature exceeds the temperature rating of -40 F to +190 (-40 C to +88 C). Humidity Install the IS Series Pressure Sensing Switch where the relative humidity does not exceed 95%, noncondensing. Fig. 11. Forcing terminals may affect the operating point. CHECKOUT M20697 Adjustment/Calibration There is no field adjustment or calibration of the IS Series Switches. All switches are calibrated and sealed at the factory

7

8 Automation and Control Solutions Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN Scarborough, Ontario M1V 4Z G.R. Rev Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

Commercial/Industrial Combustion Control Level Three Announcement

Commercial/Industrial Combustion Control Level Three Announcement Commercial/Industrial Combustion Control Level Three Announcement SUBJECT: C6097 requiring venting Model Numbers Affected: C6097A and B Ref. Number L3-08-006 Issue Date 12/9/08 Author P.Yuen/L.Ziller Date

More information

T4098A,B Deluxe Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats T4098A,B Deluxe Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides 2 F

More information

T4398A,B High Performance Electric Heat Thermostats

T4398A,B High Performance Electric Heat Thermostats T498A,B High Performance Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides

More information

The T6140A,B Remote Bulb Temperature Controller

The T6140A,B Remote Bulb Temperature Controller T640A,B Remote Bulb Temperature Controller The T640A,B Remote Bulb Temperature Controller is used as a unit mount temperature controller in electric heat, fan coil, room air conditioner applications, cold

More information

C6097A,B Pressure Switches

C6097A,B Pressure Switches C6097A,B Pressure Switches FEATURES PRODUCT DATA APPLICATION The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

CR7075 Two-Stage Lighting Controller

CR7075 Two-Stage Lighting Controller CR707 Two-Stage Lighting Controller FEATURES PRODUCT DATA Light intensity threshold levels field-adjustable by user. Independent Time of Day (TOD) override inputs. Optimum start/stop of lighting loads.

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES EC7823/RM7823 Relay Module 7800 SERIES EC7823/RM7823 Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell EC7823/RM7823 is a microprocessor based Flame Detector Relay that can be fitted with any 7800 SERIES amplifier

More information

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module FEATURES SPECIFICATION DATA APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

Q382A,B Pilot Burners

Q382A,B Pilot Burners Q382A,B Pilot Burners INSTALLATION INSTRUCTIONS APPLICATION The Q382A,B Pilot Burners provide main burner ignition for natural and LP gas-fired equipment. The design makes them ideal for use with any millivolt

More information

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7885A/RM7885A Relay Module 7800 SERIES EC7885A/RM7885A Relay Module SPECIFICATION DATA 1. Torch-ignited main burner using the S445A Start-Stop Station, or any conventional knee or foot operated start-stop station. 2. Torch-ignited

More information

T834C Heating-Cooling Thermostat

T834C Heating-Cooling Thermostat M3375 M3375 TRADELINE T834C Heating-Cooling Thermostat Application T834C Thermostats control 4 to 30 Vac single-stage heating-cooling systems. See Table for specific models and applications. An spdt mercury

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR PRODUCT DATA C7232A C7232B FEATURES Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001 SLATE Burner Control Module R8001B2001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Q7800H Integrated Burner Control Subpanel

Q7800H Integrated Burner Control Subpanel Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications.

More information

C554A Cadmium Sulfide Flame Detector

C554A Cadmium Sulfide Flame Detector C554A Cadmium Sulfide Flame Detector FEATURES PRODUCT DATA Cadmium sulfide sensing element provides faster response than bimetal sensors. On flame failure, the cad cell causes the oil primary control to

More information

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies Flame Rod Holder & Flame Rod Assemblies The small size of these devices enable their application to flame detection in installations where space is limited. The holder and flame rod assemblies facilitate

More information

T8411R Electronic Heat Pump Thermostat

T8411R Electronic Heat Pump Thermostat T84R Electronic Heat Pump Thermostat INSTALLATION INSTRUCTIONS The T84R Heat Pump Thermostat provides 24V control of two-stage heating and one-stage cooling heat pump system with manual changeover from

More information

HE365A,B Powered Flow-Through Humidifier

HE365A,B Powered Flow-Through Humidifier HE65A,B Powered Flow-Through Humidifier whole-house air quality system FEATURES/BENEFITS PRODUCT DATA Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and

More information

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES PRODUCT DATA FEATURES Solid and Split Core, Fixed Current go/no go switches. Very low operating trip points. LED

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

HE420A Steam Power Humidifier

HE420A Steam Power Humidifier READ AND SAVE THESE INSTRUCTIONS HE420A Steam Power Humidifier OWNER S GUIDE 69-1112-2 HE420A STEAM POWER HUMIDIFIER WELCOME... to the comfortable world of humidified air. With your Honeywell humidifier

More information

HE360 Powered Flow-Through Humidifier

HE360 Powered Flow-Through Humidifier HE360 Powered Flow-Through Humidifier OWNER S GUIDE U.S. Registered Trademark Copyright 1997 Honeywell Inc. All Rights Reserved WELCOME......to the comfortable world of humidified air. With your Honeywell

More information

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors C703D,G,J C70B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors PRODUCT DATA C703D, C70D C70B,C C70R C703G, C70F C70P FEATURES C703D, C70D for immersion mounting sense water temperature. C703G,

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay INSTALLATION INSTRUTIONS APPLIATION The Switching Relay provides intermediate switching of line- and low-voltage devices from a line- or low-voltage controller and is typically applied

More information

T874 Multistage Thermostat and Q674 Subbase

T874 Multistage Thermostat and Q674 Subbase SUPER TRADELINE T874 Multistage Thermostat and Q674 Subbase Application The T874D Thermostat and Q674E Subbase provide 4 to 30 Vac control of standard stage heating and stage cooling systems. The Y594D

More information

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

HE225A,B and HE265A,B Bypass Flow-Through Humidifier whole-house air quality system HE225A,B and HE265A,B Bypass Flow-Through Humidifier FEATURES/BENEFITS PRODUCT DATA Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold,

More information

CT500 Electronic Thermostat

CT500 Electronic Thermostat CT500 Electronic Thermostat OWNER'S GUIDE MERCURY NOTICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly.

More information

F150E Media Air Cleaner

F150E Media Air Cleaner whole-house air quality system FEATURES F150E Media Air Cleaner PRODUCT DATA APPLICATION F150E W8600A AIRWATCH W8600A AIRWATCH filter change indicator. High efficiency media filter captures particles as

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001 SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

HE360 Humidifier Installation Kit

HE360 Humidifier Installation Kit HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that

More information

HE365A,B Powered Flow-Through Humidifier with

HE365A,B Powered Flow-Through Humidifier with HE365A,B Powered Flow-Through Humidifier with OWNER S GUIDE IMPORTANT Please read these instructions and keep them in your records. 69-1427-04 -20 F -10 F 0 F +10 F +20 F -30 C -25 C -20 C -10 C -5 C 15%

More information

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats T7200D,E Series 2000 Commercial Microelectronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T7200D,E Thermostats provide electronic control of 24 Vac commercial single-zone heating, ventilating

More information

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats T8602C Chronotherm IV Deluxe mable Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8602 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac single-stage heating and cooling

More information

HE360A,B Powered Flow-Through Humidifier

HE360A,B Powered Flow-Through Humidifier HE360A,B Powered Flow-Through Humidifier OWNER S GUIDE U.S. Registered Trademark Copyright 1998 Honeywell Inc. All Rights Reserved 1 WELCOME... to the comfortable world of humidified air. With your Honeywell

More information

HE120, HE160 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and

More information

7800 SERIES RM7840E,G,L,M Relay Module

7800 SERIES RM7840E,G,L,M Relay Module 7800 SERIES RM7840E,G,L,M Relay Module APPLICATION SPECIFICATION DATA The Honeywell RM7840 is a microprocessor based integrated burner control for automatically fired gas, oil or combination fuel single

More information

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153 INDEX GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control... 152 GAS DRYER VALVES 153 Model(s)

More information

F25F Media Air Cleaner

F25F Media Air Cleaner F25F Media Air Cleaner FEATURES PRODUCT DATA High efficiency media filter captures particles as small as 1.0 micron. Efficiency and arrestance ratings based on the American Society of Heating, Refrigerating

More information

Zoning System Design Manual

Zoning System Design Manual Zoning Made Effortless 70-2321-03 Introduction The Concept of Zoning The basic principle of forced air zoning is to allow one HVAC system to be controlled by multiple thermostats, heating and cooling a

More information

D896 Automatic Vent Damper

D896 Automatic Vent Damper D896 Automatic Vent Damper FEATURES PRODUCT DATA 4-wire plug receptacle. Includes wiring harness on select models to fit plug receptacle onto S86/S8600/S860/S860 /L748/L848 or Penn Baso G60 or G66. For

More information

Remote Booster Power Supplies

Remote Booster Power Supplies Remote Booster Power Supplies XLS-BPS6, XLS-BPS60, XLS-BPS6C, XLS-BPS0, XLS-BPS00, XLS-BPS0C FEATURES SPECIFICATION DATA Extends power available to Notification Appliance Circuits (NACs). Available in

More information

HE365A,B Powered Flow-ThroughHumidifier with

HE365A,B Powered Flow-ThroughHumidifier with Honeywell envi ra _E,. HE365A,B Powered Flow-ThroughHumidifier with ANTI_vIICROBIAL OWNER'SGUIDE IMPORTANT _easereadthese_s_ucdonsandkeepthem _yourrecor_. 69-1427-04 OPERATINGYOUR HUMIDIFIER HE365A Your

More information

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B

More information

F112A,C; F113A,C Portable Air Cleaners

F112A,C; F113A,C Portable Air Cleaners F112A,C; F113A,C Portable Air Cleaners OWNER S GUIDE U.S. Registered Trademark Copyright 2001 Honeywell All Rights Reserved 035-00427-000 69-1506- 1 HOW YOUR PORTABLE AIR CLEANER WORKS Your air cleaner

More information

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat INSTALLATION INSTRUCTIONS APPLICATION The T7300F Thermostat provides electronic control of 24 Vac commercial single zone

More information

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE U.S. Registered Trademark Copyright 1998 Honeywell Inc. All Rights Reserved 69-1112-1 WELCOME... to the comfortable world of humidified air.

More information

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch INSTRUCTION MANUAL MM-615E 246717 Series FS1 High Sensitivity Liquid Flow Switch SPECIFICATIONS Maximum Liquid Pressure: 100 psi 7 kg/cm 2 ) Liquid Temperature Range TL): 32-225 F 0-107 C) Ambient Temperature

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

THERMOSTATS THERMOSTATS HEATING AND COOLING

THERMOSTATS THERMOSTATS HEATING AND COOLING THERMOSTATS HEATING AND COOLING LASCO CONTROLS Deluxe Horizontal Thermostats 36-0214 25 Millivolt Heat only 36-0215 1 36-0216 25 24 Volt Heat only 36-0217 1 36-0218 25 24 Volt Heat/Cool 36-0219 1 Note:

More information

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules 7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules SPECIFICATION DATA FEATURES APPLICATION The Honeywell EC7895/RM7895/RM7896 is a microprocessor based integrated burner control for automatically

More information

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat INSTALLATION INSTRUCTIONS APPLICATION The T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat provides electronic control of 24 Vac zoned heat pump

More information

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071 SLATE UV Ampli-Check Flame Amplifier R8001S1071 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform.

More information

7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module 7800 SERIES RM7888A Relay Module SPECIFICATION DATA FEATURES APPLICATION The Honeywell RM7888A Relay Module is a microprocessor-based integrated burner control for industrial process semi-automatically

More information

C7232A,B Sensor and Controller

C7232A,B Sensor and Controller C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR FEATURES PRODUCT DATA C7232A C7232B Used for CO 2 based ventilation control. Models available with LCD that provides sensor readings and status information.

More information

T8034C Heating/Cooling Thermostats

T8034C Heating/Cooling Thermostats T8034C Heating/Cooling Thermostats INSTALLATI INSTUCTIS APPLICATI These T8034C Thermostats control 4 to 30 Vac singlestage heating-cooling systems. An spdt mercury switch makes (H) to on temperature fall

More information

T8611M Deluxe Programmable Heat Pump Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats T8611M Deluxe mable Heat Pump Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Modus Model DA General Eastern Low Differential Pressure Alarm Controller GE Sensing & Inspection Technologies Modus Model DA General Eastern Low Differential Alarm Controller The Modus Model DA is a controller designed for the monitoring of low differential pressures. It combines

More information

RA889A Switching Relay

RA889A Switching Relay Switching Relay FEATURES PRODUT DATA High load switching capability. Troubleshooting LED. Push-to-test button. Replaceable transformer fuse. Long-life D relay drive control technology. Relay for use with

More information

HE365A,B Powered Flow-ThroughHumidifier with JI

HE365A,B Powered Flow-ThroughHumidifier with JI Honeywell Honeywell LUNG t HERICAN ASSOCIATION rimealtm HOUSI_ envi ra _E,_ HE365A,B Powered Flow-ThroughHumidifier with JI AN IVU;;IOBIAL OWNER'SGUIDE U.S. Registered Trademark Copyright 2003 Honeywell

More information

PART NO. COMBUSTION AIR CAP

PART NO. COMBUSTION AIR CAP ACCESSORIES FOR SPACE-RAY TUBE HEATERS VENT CAP --- Sidewall or Roof Unique design prevents back drafts and assists in drawing off and exhausting the products of combustion regardless of wind direction

More information

L8151A Triple Aquastat Relay

L8151A Triple Aquastat Relay L85A riple Aquastat Relay he L85A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service. Provides high limit, low limit, and circulator control for maintaining

More information

UV100E Ultraviolet Air Treatment System

UV100E Ultraviolet Air Treatment System UV100E Ultraviolet Air Treatment System OWNER S GUIDE U.S. Registered Trademark Copyright 2001 Honeywell Inc. All Rights Reserved 69-1442- 1 HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM WORKS When installed

More information

7800 SERIES 22-Terminal Universal Subbase

7800 SERIES 22-Terminal Universal Subbase 7800 SERIES 22-Terminal Universal Subbase FEATURES PRODUCT DATA Q7800B003/2003/U Metal Wall-mount subbase Q7800A005/2005/U Plastic Wall-mount subbase Quick-mount wiring subbase for all 7800 SERIES Relay

More information

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031 SLATE Rectification Ampli-Check Flame Amplifier R8001V1031 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single

More information

M6063A Compact Rotary Mixing Valve Actuator

M6063A Compact Rotary Mixing Valve Actuator M6063A Compact Rotary Mixing Valve Actuator PRODUC DAA FEAURES: 24 Vac floating input for automatic control. Single screw attachment to V5442 valve body. Multi-poise mounting. Color-coded position indicator.

More information

F200E Charged-Media Air Cleaner

F200E Charged-Media Air Cleaner whole-house air quality system F200E Charged-Media Air Cleaner PRODUCT DATA FEATURES APPLICATION The F200E Charged-Media Air Cleaner captures a significant amount of the air-borne particles from the air

More information

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08 16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules PRODUCT DATA indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules.

More information

Honeywell Pressure Switches Line Guide

Honeywell Pressure Switches Line Guide Honeywell Pressure Line Guide Better under pressure. For years, manufacturers and operators of heavy-duty equipment have trusted Honeywell pressure and vacuum switches. They re proven under pressure, in

More information

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES T7A, T7A,B, TA,B, TB Digital Fan-Coil Thermostats XE/XE00 SERES FEATURES PRODUCT DATA Attractive modern styling with digital display makes the thermostat ideal for offices or hotels. Hotel card key input

More information

Deluxe Programmable Heat Pump Thermostat T8611M

Deluxe Programmable Heat Pump Thermostat T8611M APPLICATION Deluxe mable Heat Pump Thermostat T8611M INSTALLATION INSTRUCTIONS The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats T8600D Chronotherm IV Deluxe mable Thermostats APPLICATION INSTALLATION INSTRUCTIONS The T8600 Chronotherm IV Deluxe mable Thermostat provides electronic control of 24 Vac singlestage heating and cooling

More information

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems APPLICATION The R7910 SOLA hydronic boiler and the R7911 SOLA steam control systems provide heat control, flame supervision, circulation

More information

C7004B Flame Rod Holder

C7004B Flame Rod Holder Honeywell These Flame Rod Holders facilitate the use of flame rods for flame proving on gas burners or gas-pilot ignited oil burners controlled by electronic flame safeguard control systems. C7004B Flame

More information

Electronic Thermostat

Electronic Thermostat Set FAN Auto On Room SYSTEM Cool Off Heat M18535 Electronic Thermostat OWNER S GUIDE Em Ht Aux Ht Set Room FAN Auto On SYSTEM Cool Off Heat Em.Ht. M18539 1 69-1490 69-1490 Congratulations on the purchase

More information

Must be installed by a trained, experienced technician

Must be installed by a trained, experienced technician Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8321097: For up to 3 Heat/2 Cool heat pump or up to 2 Heat/2 Cool conventional

More information

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 DESCRIPTION FEATURES PRODUCT DATA Solid and Split Core Vdc Output Current Transmitters. Fast Response Time. Integral

More information

Schneider Electric Erie T155 Series

Schneider Electric Erie T155 Series Schneider Electric Erie T Series Non-Digital, On/Off Thermostat General Instructions Application The T series thermostat provides on/off control for low voltage and line voltage valves, relays and fan

More information

TC-5231 Series, TC-5232, & TC-5241 Series

TC-5231 Series, TC-5232, & TC-5241 Series TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air

More information

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module 7800 SERIES RM7840E,G,L,M; EC7840L Relay Module SPECIFICATION DATA Valve Proving features including: VPS test time When (Never, Before, After, Split or Both) FEATURES APPLICATION The Honeywell RM7840 is

More information

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction 3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction Automatic reset thermostat designed to meet your specific application requirements. Its patented and tamper proof snap action bi-metal disc provides

More information

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS 63-2652 FEATURES Typically used in buildings (including: restaurants, shopping malls, office buildings and banks) under 55,000 square feet.

More information

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats T8624D Chronotherm IV Deluxe mable Multistage Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8624D Chronotherm IV Deluxe mable Multistage Thermostats provides electronic control of 24 Vac single-zone

More information

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4 Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Q7300H Series 2000 Commercial Thermostat Subbases

Q7300H Series 2000 Commercial Thermostat Subbases Q700H Series 000 Commercial hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700H hermostat Subbases are used with 700F hermostats to provide electronic control of commercial Vac single or multistage

More information

Home and Building Control Home and Building Control Helping You Control Your World

Home and Building Control Home and Building Control Helping You Control Your World M3375 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited/Honeywell Limitée 1985 Douglas Drive No. 740 Ellesmere Road Golden Valley, MN 55422

More information

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules R784, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules PRODUCT DATA The R7851C Dynamic Self- Optical lame Amplifier is a solid state plug-in amplifier that responds to ultraviolet

More information

Heat Recovery Ventilation Systems OWNER S GUIDE

Heat Recovery Ventilation Systems OWNER S GUIDE Heat Recovery Ventilation Systems OWNER S GUIDE U.S. Registered Trademark Copyright 2002 All Rights Reserved 69-1657 CONTENTS Introduction.........................................................3 Feeling

More information

Instructions For A and Flame Simulators

Instructions For A and Flame Simulators Instructions For 123514A and 203659 Flame Simulators Application Flame simulators are devices that simulate a flame by reproducing ultraviolet resistance or rectification characteristics of an actual flame.

More information

T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE

T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE 69-1396-1 Features Digital temperature sensing and control for energy efficient precision operation. Flexibility of 5-1-1

More information

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20 PRODUCT DATA FEATURES Solid or split core loop-powered current transmitters Fast response time Integral DIN rail mounting flange

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. Installation & Maintenance Instructions MM-616 Series FS-5 General Purpose Liquid Flow Switch specified models only) Series FS-5 OPERATION This control is an independently mounted water flow sensing device

More information