SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11
|
|
- Randolph Walker
- 6 years ago
- Views:
Transcription
1 M-SERIES SUBMITTAL DATA: MSZ-FH0NA & MUZ-FH0NA,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH0NA Wireless Remote Controller : MUZ-FH0NA Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-889SG) Base Pan Heater (MAC-0BH-U) Drain Socket (MAC-80DS) Controls Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W,000 / 35 at 7º F Btu/h / W 8,700 / 55 Capacity Range Minimum Maximum Btu/h,700 9,000 at 7º F Btu/h,00,000 at 7º F 3 Btu/h - 0,700 at 5º F Btu/h - 8,700 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF 33. / 3.5 COP at 7 o F / 7 o F.8 / 3. Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.9 / 0. pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary WET DRY Outdoor,50 /,80 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) Lbs.(kg) + / x 3-7/ x 9-3/ ( x 95 x 3) -5/8 x 3-/ x -/ (550 x 800 x 85) 9 () Outdoor 8 (37) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; lb. 9 oz. / (.35) Gas (Low Pressure) 3/8 (9.5) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 0 () 5 (0) 0 Mitsubishi Electric US, Inc.
2 DIMENSIONS: MSZ-FH0NA & MUZ-FH0NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA MSZ-FH0NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH0NA MUZ-FH0NAH MUZ-FH09NA MUZ-FH09NAH MUZ-FHNA MUZ-FHNAH MUZ-FH0NA REQUIRED SPACE * in. (00 mm) when front and sides of the unit are clear in. (00 mm) clear * in. (00 mm) (MUZ-FH0/09/NA) (MUZ-FH0/09/NAH) 8 in. (00 mm) * in. (350 mm) * When any sides of left, right and rear of the unit are clear x hole 3/8 x 3/ Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 OBH83D OBH83D 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: FORM# MSZ-FH0NA ~ MUZ-FH0NA Mitsubishi Electric US, Inc.
3 M-SERIES SUBMITTAL DATA: MSZ-FH09NA & MUZ-FH09NA- 9,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH09NA Wireless Remote Controller Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-889SG) Base Pan Heater (MAC-0BH-U) Drain Socket (MAC-80DS) Controls : MUZ-FH09NA- Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W 9,000 / 50 at 7º F Btu/h / W 0,900 / 70 Capacity Range Minimum Maximum Btu/h,700,000 at 7º F Btu/h,00 8,000 at 7º F 3 Btu/h -,00 at 5º F Btu/h - 0,900 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF 30.5 / 3.5 COP at 7 o F / 7 o F.5 / 3.33 Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.9 / 0. pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary WET DRY Outdoor,50 /,80 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) Lbs.(kg) + / x 3-7/ x 9-3/ ( x 95 x 3) -5/8 x 3-/ x -/ (550 x 800 x 85) 9 () Outdoor 8 (37) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; lb. 9 oz. / (.35) Gas (Low Pressure) 3/8 (9.5) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 0 () 5 (0) 0 Mitsubishi Electric US, Inc.
4 DIMENSIONS: MSZ-FH09NA & MUZ-FH09NA- MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA MSZ-FH09NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH0NA MUZ-FH0NAH MUZ-FH09NA MUZ-FH09NAH MUZ-FHNA MUZ-FHNAH MUZ-FH09NA- REQUIRED SPACE * in. (00 mm) when front and sides of the unit are clear in. (00 mm) clear * in. (00 mm) (MUZ-FH0/09/NA) (MUZ-FH0/09/NAH) 8 in. (00 mm) * in. (350 mm) * When any sides of left, right and rear of the unit are clear x hole 3/8 x 3/ Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 OBH83D OBH83D 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: FORM# MSZ-FH09NA ~ MUZ-FH09NA Mitsubishi Electric US, Inc.
5 M-SERIES SUBMITTAL DATA: MSZ-FHNA & MUZ-FHNA-,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FHNA Wireless Remote Controller Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-889SG) Base Pan Heater (MAC-0BH-U) Drain Socket (MAC-80DS) Controls : MUZ-FHNA- Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W,000 / 870 at 7º F Btu/h / W 3,00 / 950 Capacity Range Minimum Maximum Btu/h,500 3,00 at 7º F Btu/h 3,700,000 at 7º F 3 Btu/h - 3,00 at 5º F Btu/h - 3,00 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF. /.5 COP at 7 o F / 7 o F. / 3.3 Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.83 /.9 pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary WET DRY Outdoor,90 /,30 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) Lbs.(kg) + / x 3-7/ x 9-3/ ( x 95 x 3) -5/8 x 3-/ x -/ (550 x 800 x 85) 9 () Outdoor 83 (38) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; lb. 9 oz. / (.35) Gas (Low Pressure) 3/8 (9.5) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 0 () 5 (0) 0 Mitsubishi Electric US, Inc.
6 DIMENSIONS: MSZ-FHNA & MUZ-FHNA- MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA MSZ-FHNA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH0NA MUZ-FH0NAH MUZ-FH09NA MUZ-FH09NAH MUZ-FHNA MUZ-FHNAH MUZ-FHNA- REQUIRED SPACE * in. (00 mm) when front and sides of the unit are clear in. (00 mm) clear * in. (00 mm) (MUZ-FH0/09/NA) (MUZ-FH0/09/NAH) 8 in. (00 mm) * in. (350 mm) * When any sides of left, right and rear of the unit are clear x hole 3/8 x 3/ Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 OBH83D OBH83D 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: FORM# MSZ-FHNA ~ MUZ-FHNA Mitsubishi Electric US, Inc.
7 M-SERIES SUBMITTAL DATA: MSZ-FH5NA & MUZ-FH5NA 5,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Electrical Power Requirements 08 / 30V, -Phase, 0 Hz ACCESSORIES: Unit Unit: MSZ-FH5NA Wireless Remote Controller : MUZ-FH5NA Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Air Discharge Guide (MAC-88SG-E) Base Pan Heater (MAC-BH-U) Drain Socket (MAC-85DS) Controls Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) SPECIFICATIONS: Rated Conditions (Capacity / Input) Btu/h / W 5,000 /,00 at 7º F Btu/h / W 8,000 /,300 Capacity Range Minimum Maximum Btu/h,50 9,000 at 7º F Btu/h 5,50,000 at 7º F 3 Btu/h - 8,000 at 5º F Btu/h - 8,000 : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB * at 7ºF : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB * 3 at 7º F : 70º F(º C)DB / 0º F(º C)WB; Outdoor: 7º F(-8º C)DB / 5º F(-9º C)WB * at 5º F : 70º F (º C)DB / 0º F(º C)WB; Outdoor: 5º F(-5º C) DB / 5º F(-5º C)WB * Rating Conditions per AHRI Standard: Operating Conditons ( Intake Air Temp.) (Max./ Min.) 90º F (3º C) DB / 7º F (9º C) DB 80º F (7º C) DB / 70º F (º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) 5º F (º C) DB / º F (-0º C) DB 75º F (º C) DB / -3º F (-5º C) DB** 5 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. ** System cuts out at -8º F (-8º C) to avoid thermistor error and automatically restarts at -º F (-º C). AHRI Efficiency Ratings SEER / HSPF / COP at 7 o F / 7 o F.0 / 3.9 Energy Star Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Minimum Circuit Ampacity (MCA) / Outdoor A / Unit Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 SHF / Moisture Removal 0.70 /.0 pt./h Field Drainpipe Size O.D. 5/8 (5) Compressor Fan Motor (ECM) F.L.A Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) () () DRY CFM DC INVERTER-driven Twin Rotary WET DRY Outdoor,0 /,0 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Outdoor External Dimensions (H x W x D) Outdoor (H x W x D) Net Weight db(a) Lbs.(kg) + / x 3-7/ x 9-3/ ( x 95 x 3) 3-5/8 x 33-/ x 3 (880 x 80 x 330) 9 () Outdoor (5) External Finish Munsell.0Y 9. / 0. Outdoor Munsell No. 3Y 7.8 /. Refrigerant Refrigerant Piping (Flared) Liquid (High Pressure) R0A; 3 lb. 7 oz. / (.35) Gas (Low Pressure) / (.7) Pipe Length (Height Diff.) Pipe Length (Length.) Ft. (m) 50 (5) 00 (30) 0 Mitsubishi Electric US, Inc.
8 AND DIMENSIONS A MSZ-FHNA MSZ-FH5NA DIMENSIONS: MSZ-FH8NA MSZ-FH5NA MSZ-FH8NA& MUZ-FH5NA MSZ-FH5NA MSZ-FH0NA MSZ-FH09NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH8NA (MSZ-FH5/8NA/8NA) (MSZ-FH0/09/NA) (MSZ-FH5/8NA/8NA) MUZ-FH5NA MUZ-FH5NAH MUZ-FH8NA MUZ-FH8NAH MUZ-FH8NA MUZ-FH8NAH 3 MUZ-FH5NA Air in -7/ Air in -7/ Air in Drain hole -9/ Drain hole -9/ * 0 in. (500 mm) when front REQUIRED and sides of the SPACE unit are clear -5/8-3/ REQUIRED SPACE * 0 in. (500 mm) when front and sides of the unit are clear -5/8 in. (00 mm) in. (00 mm) Clear * Clear * in. (00 mm) in. (00 mm) 3 Air in Air out -7/8 9-/ Air out -7/8 9-/ 33-/ -5/ 33-/ -5/ -3/ x hole 3/3 x 3/ x hole 3/3 x 3/ 3-3/ 3-3/ 0 in. (500 mm) * in. (350 mm) in. (350 mm) * When any sides of left, right and rear of the unit are clear 0 in. (500 mm) * * When any sides Service of left, panel right and rear of the unit are clear Service panel Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / 3-5/8 Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø / 3-5/8 7-5/3 7-5/3 OBH83D FORM# MSZ-FH5NA / MUZ-FH5NA / 3-9/3 -/ 3-9/3 7-/ 7-/ Gas refrigerant pipe joint Refrigerant pipe (flared) Ø / Gas refrigerant pipe joint Refrigerant pipe (flared) Ø / 30 Satellite Boulevard. Suwanee, GA 300 Toll Free: Mitsubishi Electric US, Inc.
9 M-SERIES SUBMITTAL DATA: MSZ-FH8NA 8,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: SPECIFICATIONS: Rated Capacity* Btu/h / W 7,00 at 7º F Btu/h / W 0,300 Unit: MSZ-FH8NA Wireless Remote Controller ACCESSORIES: Unit Condensate Pump (BlueDiamond X87-7/7; 5/30V) Condensate Pump (Sauermann SI30-5/30; 5/30V) Replacement Platinum Deodorizing Filter (MAC-3000FT-E) Replacement Anti-allergy Enzyme Filter (MAC-330FT-E) Controls Wireless Controller (MHK) Wired Remote Controller PAR-3MAA (Requires MAC-333IF-E) Wireless Interface for kumo cloud (PAC-WHS0WF-E) Thermostat Interface (PAC-USCN-) Rating Conditions per AHRI Standard: : 80º F(7º C)DB / 7º F(9º C)WB; Outdoor: 95º F(35º C)DB / 75º F(º C)WB at 7º F : 70º F (º C)DB / 0º F (º C)WB; Outdoor: 7º F (8º C)DB / 3º F (º C)WB For data on specific indoor units (all ducted, all non-ducted, and both ducted and non-ducted) combinations, see the MXZ Technical and Service Manual. Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Power Requirements Minimum Circuit Ampacity (MCA) 08 / 30V, -Phase, 0 Hz A Blower Motor (ECM) F.L.A. 0.7 Blower Motor Output W 30 Field Drainpipe Size O.D. 5/8 (5) Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) DRY CFM WET DRY Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) db(a) External Dimensions (H x W x D) + / x 3-7/ x 9-3/ ( x 95 x 3) Net Weight Lbs.(kg) 9 () External Finish Munsell.0Y 9. / 0. Refrigerant Piping (Flared) Liquid (High Pressure) / (.35) Gas (Low Pressure) / (.7) 05 Mitsubishi Electric US, Inc.
10 Piping Ø O.D Ø3/8 9-/ (Flared connection Ø3/8) Ø/ 7-/ (Flared connection Ø5/8) Insulation Ø-/8 Connected part Ø5/8 O.D MSZ-FH8NA MSZ-FHNA MSZ-FH5NA MSZ-FH8NA MSZ-FH09NA Unit: mm (in.) 7/ -/ Oblong hole unit -5/8-3/ 5-9/ -/ 0-/8 3-9/ Wall hole Ø3 Air in 9-3/ 7-/ -9/ -5/ / Air out -3/ -3/8 Piping / / 9-5/8-3/8 3-5/ Installation plate -5/8 3/8 8-/8 3/ -3/ -/ 7/8 8-7/8 8-/ 3/8 9-5/ 0-3/ 35-5/8-7/8 3-7/ 8-7/8 9-/ 7/ 3/ Oblong hole Installation plate -/ 8-/ -9/ -7/8 -/ -/ -/ Insulation Liquid line Gas line Drain hose DIMENSIONS: MSZ-FH8NA -3/ -9/ Drain hose -5/8-5/8 Piping (MSZ-FH09/NA) Insulation Liquid line Gas line Drain hose Ø-7/ O.D Ø/ 9-/ (Flared connection Ø/) Ø3/8-5/ (Flared connection Ø3/8) Insulation Ø-/8 Connected part Ø5/8 O.D -/ (MSZ-FH5/8NA) Piping 7-5/8 5-3/ Insulation Liquid line Gas line Drain hose Ø-7/ O.D Ø/ 9-/ (Flared connection Ø/) Ø3/8-5/ (Flared connection Ø/) Insulation Ø-/8 Connected part Ø5/8 O.D 9 30 Satellite Boulevard Suwanee, GA 300 Toll Free: FORM# MSZ-FH8NAFOR MXZ-C MULTI-ZONE SYSTEMS Mitsubishi Electric US, Inc.
SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating
M-SERIES SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: ENERGY STAR...Yes ENERGY STAR products are third-party certified by an
More informationSUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS
SUBMITTAL DATA: SLZ-KA9NA......... 9, BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction
More informationSUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:
M-SERIES SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: MSY-GL12NA Outdoor Unit: MUY-GL12NA Wireless Remote Controller
More informationSUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:
M-SERIES SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: MSY-GL24NA Outdoor Unit: MUY-GL24NA Wireless Remote Controller
More informationM-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction
SUBMITTAL DATA: ** & SUZ-KA15NA 15, BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMS M-SERIES Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation:
More information1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5
M-SERIES SINGLE ZONE SYSTEMS MSZ-FH High Performance Wall-Mount Heat Pump Systems 1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5 3-1. SPECIFICATIONS... MSZ-FH-6 MSZ-FH09NA
More informationSUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:
P-SERIES SUBMITTAL DATA: & 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: : : INDOOR UNIT FEATURES Ducted air handler provides a solution to cool and heat large zones Highly
More informationSUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7
P-SERIES SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS INDOOR
More informationSUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7
P-SERIES SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PVA-A36AA7 PUY-A36NKA7 PUY-A36NKA7-BS
More informationSUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7
P-SERIES SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A12AA7 PUZ-A12NKA7 PUZ-A12NKA7-BS
More informationSUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7
P-SERIES SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PEAD-A42AA7 PUZ-A42NKA7 PUZ-A42NKA7-BS
More informationSUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7
P-SERIES SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: PCA-A24KA7 Outdoor Unit: PUZ-A24NHA7 PUZ-A24NHA7-BS
More informationSUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7
P-SERIES SUBMITTAL DATA: PEAD-A30AA7 & (-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM Job Name: System Reference: Indoor Unit: PEAD-A30AA7 Date: Outdoor Unit: -BS INDOOR UNIT FEATURES Unobtrusive
More informationSUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:
P-SERIES SUBMITTAL DATA: & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM Job Name: System Reference: : Date: : PUY-A24NHA7 PUY-A24NHA7-BS INDOOR UNIT FEATURES Unobtrusive ceiling-concealed
More informationRevision C: Specification has been corrected. The value of "Moisture removal" for MSZ-GE24NA and MSY-GE24NA has been corrected. [2.7 pt.
Use the speciþed refrigerant only Never use any refrigerant other than that specified. Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. Correct refrigerant
More informationSUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7
P-SERIES SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A24EA7 PUY-A24NHA7 PUY-A24NHA7-BS INDOOR
More informationSERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH
Revision D: Capacity corrections have been corrected [7-1. 2), 3)]. OBH684 REVISED EDITION-C is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH684 REVISED EDITION-D Models MUZ-FH06NA MUZ-FH09NA
More informationSUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7
P-SERIES SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A12EA7 PUZ-A12NKA7 PUZ-A12NKA7-BS INDOOR
More informationSUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7
P-SERIES SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H -CASSETTE HEAT PUMP SYSTEM Job Name: System Reference: Date: Indoor Unit: Outdoor Unit: PLA-A36EA7 PUZ-A36NKA7 PUZ-A36NKA7-BS INDOOR
More informationSubmittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System
Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationSubmittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System
Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote
More informationSubmittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationSubmittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless
More informationPower Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.
Submittal Data: CROWN09HP230V1B Superior Performance in Extreme Temperature 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule
More informationInnovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date
Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser
More informationSubmittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To
Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More information15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Swing Louvers -Wireless
More information18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -4-way Discharge Air -Internal Condensate
More informationM-SERIES PRODUCT CATALOG
M-SERIES PRODUCT CATALOG Zoned Comfort Solutions www.mitsubishicomfort.com MAKE COMFORT PERSONAL Make Comfort Personal. It s not just a tag line or a marketing slogan. It s what we do every day. No other
More informationSubmitted to: For Reference Approval Construction
SUBITTAL DATA: SEZ-KD9A & SUZ-KA9A............... 9, BTU/H HORIZOTAL-DUCTED HEAT-PUP SYSTES Job ame: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation:
More informationwww.mitsubishicomfort.com Comfort is a concept many of us notice most when we re uncomfortable. And comfort is our #1 priority at Mitsubishi Cooling and Heating Solutions. Our innovative split zoned cooling
More informationSERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A
Revision B: MUZ-GL09NA- U8 and MUZ-GL09NAH- U8 have been added. Please void OBH733 REVISED EDITION-A. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH733 REVISED EDITION-B Models MUZ-GL09NA
More informationM-Series RESIDENTIAL AND SELECT COMMERCIAL. MS MSY MSZ MXZ
M-Series RESIDENTIAL AND SELECT COMMERCIAL Air conditioners AND Heat pumps MS MSY MSZ MXZ www.mrslim.com Mr. Slim Split-ductless Systems: Redefining Comfort Comfort is a concept many of us notice only
More informationSERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC
Revision A: MUZ-HM09/12NA- U8, MUZ-HM09/12NA2- U8, MUZ-HM15/18NA- U1, MUZ-HM15/18NA2- U1 and MUZ-HM24NA2- U1 have been added. Please void OBH747. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A.
More informationDuctless Split Systems Concealed Duct Heat Pumps
Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH
More informationINVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.
INVERTER-driven Split-ductless and ducted Comfort Systems M Series Full Line Catalog www.mitsubishicomfort.com Mitsubishi Electric Cooling and Heating Solutions Mitsubishi Electric HVAC products, available
More informationThe Hyper-Heat Advantage
The Hyper-Heat Advantage * What is? SUMMER WINTER The Mitsubishi Electric Zuba is a heat pump system, which provides excellent heating performance in the winter and effortlessly cools your home in the
More informationDuctless Split Systems Ceiling Cassette Heat Pumps
Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE
More informationDuctless Split Systems Wall-mounted, Single Zone Heat Pump
Ductless Split Systems Wall-mounted, Single Zone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H
More information1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.
1 TECHNICAL CHANGES MUZ09UN MUZ-A09NA MUZ12UN MUZ-A12NA MUH15TN MUZ-A15NA MUH17TN MUZ-A17NA MUH24WN MUZ-A24NA MU15TN MUY-A15NA MU17TN MUY-A17NA MU24WN MUY-A24NA 1. Outdoor unit model has been changed.
More information15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)
Innovative Ductless Mini Split Solution Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Multi-Speed Fan -Medium Static Pressure Capability -Return
More informationMarket District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems
Market District Commons Black Oak Engineering Daikin Ductless Heat Pump Split Systems N/A N/A M001 Plans Fujitsu ductless heat pump systems 353 Rte. 46 West Fairfield, NJ Fujitsu Fujitsu Halcyon 07004
More informationZONED COMFORT SOLUTIONS
M-SERIESCATALOG ZONED COMFORT SOLUTIONS M-SERIES CATALOG I 05.2018 I WWW.MITSUBISHICOMFORT.COM MAKE COMFORT PERSONAL Make Comfort Personal. It s not just a tagline or a marketing slogan. It s what we do
More informationSERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1
Revision B: 3. SPECIFICATION has been corrected. Please void OBH732 REVISED EDITION-A. INDOOR UNIT SERVICE MANUAL. OBH732 REVISED EDITION-B Models MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA
More informationWell rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.
360 CASSETTE Well rounded. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting. Product Registration Required Conditions Apply 2017 Samsung HVAC 63714_SAMSUN_360_Cassette_v13.indd
More informationProduct Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56
38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND
More informationSamsung 360 Cassette, Single Zone, Split System
Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...
More informationCold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply
Cold Remedies. Meet the Max Heat family. The ideal solutions for the harshest of colds. Our Max Heat units provide high heating capacity at -13 F to keep you comfortable. Look inside for our complete line
More informationIT'S HARD TO STOP A TRANE
IT'S HARD TO STOP A TRANE WWW.TRANE.COM/RESIDENTIAL THE FUTURE OF HOME COMFORT We offer a superior alternative to traditional HVAC systems. Our ductless and ducted heating and cooling systems focus on
More informationHEAT PUMPS. Efficient Comfort For Every Season
HEAT PUMPS Evergreen Series Efficient Comfort For Every Season 1 Evergreen Series Efficient Comfort For Every Season THE WORLD S MOST EFFICIENT HEAT PUMP The Yukon series is rated the world s most efficient
More informationA single answer for multiple zones.
Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available
More informationJanuary Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC
January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features
More informationA single answer for multiple zones.
FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available
More informationTHE WORLD S MOST EFFICIENT HEAT PUMP
HEAT PUMPS THE WORLD S MOST EFFICIENT HEAT PUMP The LOMOPLUS is rated the world s most efficient heat pump in both cooling and heating modes and also in every capacity from 9,000 BTU to 24,000 BTU. Being
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationGeniuses at work. Residential Mini Splits
Residential Mini Splits Smart Pearl Smart Whisper Geniuses at work. Two smart ways to heat and cool your home. Be the smartest person in the room when you get your home equipped with a Wi-Fi enabled heat
More informationSingle and Multi-Zone Ductless Split Systems
Presents Single and Multi-Zone Ductless Split Systems EnviroAir Ductless Split Systems by EMI provide homeowners and light commercial establishments economical solutions when only area cooling and heating
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationRedefining Comfort. Mr. Slim Splitductless
www.mrslim.com Mr. Slim Splitductless Systems Redefining Comfort R410A Wireless M- Series Remote M- Series M- Series Comfort is a concept many of us notice only when we re either uncomfortable or extremely
More informationWhy Choose Mitsubishi Electric?
Split Systems Why Choose Mitsubishi Electric? As a leading company in the industry, Mitsubishi Electric has a proud history in the manufacturing and supply of leading edge electrical and electronic equipment
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationHigh Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series
AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling
More informationPERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems
PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems www.emiretroaire.com PN 240012598 REV. [03/20/2019] Single Zone & Multi-Zone Systems Deluxe Heat Series HEAT PUMP ductless mini splits with
More informationSERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.
Revision F: The descriptions of the expansion valve coil have been corrected. (10-4.) Some descriptions have been modified. Please void OBH543 REVISED EDITION-E. OUTDOOR UNIT SERVICE MANUAL HFC utilized
More informationSERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A
Revision E: Capacity corrections have been corrected [7-1. 2), 3)]. OBH502 REVISED EDITION-D is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 REVISED EDITION-E Models MUZ-D30NA / - 1 / -
More informationDuctless Split Systems Wall-mounted, Multizone Heat Pump
Ductless Split Systems Wall-mounted, Multizone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE
More informationSERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A
OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH502 Wireless type Models MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA Indoor unit service manual MSZ-D NA Series (OBH501) MSY-D
More informationP-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.
P-Series Full-line Catalog Commercial-grade Applications Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems www.mitsubishipro.com 1 Take a Closer Look at the P-Series Commercial Systems
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationMSZ-GE06NA- 8, 9 MSZ-GE09NA- 8, 9 MSZ-GE12NA- 8, 9 MSZ-GE15NA- 8, 9 MSZ-GE18NA- 8, 9
SPLIT-TYPE AIR CONDITIONERS Revision D: MSZ-GE06/09/12/15/18NA- 9 and MSY- GE09/12/15/18NA- 9 have been added. Please void OBH548 REVISED EDITION-C INDOOR UNIT SERVICE MANUAL. OBH548 REVISED EDITION-D
More informationP-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.
P-Series Full-line Catalog Commercial-grade Applications Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems www.mitsubishipro.com Take a Closer Look at the P-Series Commercial Systems
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationCU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,
Order No. MAC0605029C2 Air Conditioner CS-F18DTE5 CU-B34DBE5 CS-F18DTE5 CU-B34DBE8 CS-F24DTE5 CU-B43DBE8 CS-F28DTE5 CU-B50DBE8 Please file and use this manual together with the service manual for Model
More informationHighly Efficient,Powerful Heating and Cooling.
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2
More informationMUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC
Revision E: MUZ-FH25VE- E4, ER4, ET3, MUZ- FH35VE- E3, ER3, ET3 and MUZ- FH50VE- E2, ER2, ET2 have been added. Please void OBH624 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624
More informationDuctless Split Systems. J Series. The Next Generation of Ductless Split Systems
Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation
More informationProduct Data INDUSTRY LEADING FEATURES / BENEFITS
8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS G07LLCC AS G09LLCC AS G12LLCC OUTDOOR AO G07LLCC AO G09LLCC AO G12LLCC 1.INDOOR UNIT : AS G07LLCC AS G09LLCC AS G12LLCC DTR_AS087E_02
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFW AOU24RLXFW 1. INDOOR UNIT : ASU18RLF ASU24RLF DTR_AS51E_1 21.12.22 1. INDOOR UNIT CONTENTS 1. FEATURE...
More informationDuctless Split Systems. J Series. The Next Generation of Ductless Split Systems
Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationWall Mounted Air Conditioner
Mu ti S it ho ous So utions Wall Mounted Air Conditioner 1hr off timer Weekly Timer System ler Filter sign Auto Restart Fresh Air intake Branch Extension Drain Pump Low Ambient Elect.Valve ODP0 Refrigerant
More information2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS
2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS Midea Company Profile Established in 1968, Midea Group has grown into a leading consumer appliances and HVAC systems manufacturer. With over 8,000 employees,
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationSUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:
M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH
More informationDUCTLESS FULL LINE CATALOG
DUCTLESS FULL LINE CATALOG Spring 2016 Edition 1 Versatile Ductless Systems can increase your sales opportunities Bryant offers a complete line of ductless HVAC systems designed to make any space more
More informationSERVICE MANUAL MUZ-FE09NA MUZ-FE12NA OUTDOOR UNIT. No. OBH543. Models HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH543 Models MUZ-FE09NA MUZ-FE12NA Indoor unit service manual MSZ-FE NA Series (OBH542) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More informationK sin. Mini Split Air Conditioners and Heat Pump
Mini Split Air Conditioners and Heat Pump K sin Environment concern is a priority all over the world. Environment concern is our responsibility and working philosophy. 140 105 70 35 Noise Level db(a) Level
More informationSERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2
Revision F: "How to check miswiring and serial signal error" has been corrected (11-5. M ). OBH648 REVISED EDITION-E is void. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH648 REVISED EDITION-F Models
More informationSUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:
M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating
More informationFREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com
FREE JOINT MULTI Multi-Zone Mini Split Air Conditioner *Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰ quietside.com Ver 1-7.13 F DB, 43⁰F WB. FREE JOINT MULTI - Features and
More informationDUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA
DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA SERIES ALEGRIA PLATINUM SERIES ALEGRIA GOLD SERIES 3 DUCTLESS MINI-SPLITS SERIES TO CHOOSE FROM ALEGRIA ALEGRIA SERIES
More informationProduct Data INDUSTRY LEADING FEATURES / BENEFITS
8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design
More informationHIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE
HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating
More informationR-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:
Ozone Friendly Refrigerant Variable Compressor Speed Ductless Split Systems Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Technology IAQ Catechin Plus Air Purifying System 13 to 17 SEER
More informationKlimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE
Klimaire 16 SEER CENTRAL DUCTED Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units 10 YEAR LIMITED GUARANTEE R410A R E F R I G E R A N T CSM Condensing Units Features Condensing
More information