FXAQ-PVJU Wall Mounted Type

Size: px
Start display at page:

Download "FXAQ-PVJU Wall Mounted Type"

Transcription

1 FXAQ-PVJU Wall Mounted Type AMERICAS

2 FXAQ-PVJU Wall Mounted Type 1. Specifications Dimensions Piping Diagrams Wiring Diagrams Electric Characteristics Safety Devices Setting Capacity Tables Cooling Capacity Heating Capacity Air Velocity and Temperature Distributions (Reference Data) Sound Levels (Reference) Overall Octave Band Level Installation Accessories Indoor Unit Installation Drain Piping Work Electrical Wiring Work Field Settings Test Run Accessories Optional Accessories (For Controls)...41 FXAQ-PVJU 1

3 Specifications 1. Specifications Wall Mounted Type Model FXAQ07PVJU FXAQ09PVJU FXAQ12PVJU Power Supply 1 phase, 208/230V, 60Hz 1, 3 Cooling Capacity Btu/h 7,500 9,500 12,000 2, 3 Heating Capacity Btu/h 8,500 10,500 13,500 Casing Color White (3.0Y8.5/0.5) White (3.0Y8.5/0.5) White (3.0Y8.5/0.5) Dimensions: (H W D) in (mm) 11 3/8 31 1/4 9 1/4 11 3/8 31 1/4 9 1/4 11 3/8 31 1/4 9 1/4 (289 x 794 x 235) (289 x 794 x 235) (289 x 794 x 235) Coil (Cross Rows Stages FPI Fin Coil) Face Area ft² (m²) Model QCL9661M QCL9661M QCL9661M Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Fan Motor Output W Air Flow Rate (H/L) cfm (m 3 /min) 260/160 (79/49) 280/175 (85/53) 290/180 (88/55) Drive Direct Drive Direct Drive Direct Drive Temperature Control Microprocessor Thermostat for Cooling and Heating Microprocessor Thermostat for Cooling and Heating Microprocessor Thermostat for Cooling and Heating Sound Absorbing Thermal Insulation Material Notes: Foamed Polystyrene / Foamed Polyethylene 1 Nominal cooling capacities are based on the following conditions: Return air temperature: 80 FDB, 67 FWB (27 CDB /19.4 CWB) Outdoor temperature: 95 FDB (35 CDB) Equivalent ref. piping length: 25ft (7.5 m) (Horizontal) 2 Nominal heating capacities are based on the following conditions: Return air temperature: 70 FDB (21 CDB). Outdoor temperature: 47 FDB, 43 FWB (8.3 CDB / 6 CWB) Equivalent ref. piping length: 25ft (7.5 m) (Horizontal) 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Sound levels are measured under JIS conditions. 5 Refer to page 9 for Power Input. Foamed Polystyrene / Foamed Polyethylene Foamed Polystyrene / Foamed Polyethylene Air Filter Resin Net (Washable) Resin Net (Washable) Resin Net (Washable) Machine Weight (Mass) Lbs (kg) 26 (12) 26 (12) 26 (12) Piping Connections Liquid Pipes in (mm) 1/4 (6.4) (Flare Connection) 1/4 (6.4) (Flare Connection) 1/4 (6.4) (Flare Connection) Gas Pipes in (mm) 1/2 (12.7) (Flare Connection) 1/2 (12.7) (Flare Connection) 1/2 (12.7) (Flare Connection) Drain Pipe in (mm) VP13 (External Dia. 11/16 (17.5) Internal Dia. 1/2 (12.7)) VP13 (External Dia. 11/16 (17.5) Internal Dia. 1/2 (12.7)) VP13 (External Dia. 11/16 (17.5) Internal Dia. 1/2 (12.7)) 4 Sound Level (H/L) db(a) 36/31 37/31 38/31 Safety Devices Fuse Fuse Fuse Refrigerant Control Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Connectable outdoor unit R-410A VRV Series R-410A VRV Series R-410A VRV Series Standard Accessories Drawing No. Operation Manual, Installation Manual, Installation Panel, Paper Pattern for Installation, Insulation Tape, Insulation Tube, Clamps, Screws. Operation Manual, Installation Manual, Installation Panel, Paper Pattern for Installation, Insulation Tape, Insulation Tube, Clamps, Screws. C: 3D075572A Operation Manual, Installation Manual, Installation Panel, Paper Pattern for Installation, Insulation Tape, Insulation Tube, Clamps, Screws. 2 FXAQ-PVJU

4 Specifications Wall Mounted Type Model FXAQ18PVJU FXAQ24PVJU Power Supply 1 phase, 208/230V, 60Hz 1, 3 Cooling Capacity Btu/h 18,000 24,000 2, 3 Heating Capacity Btu/h 20,000 26,500 Casing Color White (3.0Y8.5/0.5) White (3.0Y8.5/0.5) Dimensions: (H W D) in (mm) 11 3/8 41 3/8 9 1/4 11 3/8 41 3/8 9 1/4 (289 x 1051 x 235) (289 x 1051 x 235) Coil (Cross Rows Stages FPI Fin Coil) Face Area ft² (m²) 2.29 (0.7) 2.29 (0.7) Model QCL9686M QCL9686M Type Cross Flow Fan Cross Flow Fan Fan Motor Output W Air Flow Rate (H/L) cfm (m 3 /min) 500/400 (152/122) 635/470 (194/143) Drive Direct Drive Direct Drive Temperature Control Microprocessor Thermostat for Cooling and Heating Microprocessor Thermostat for Cooling and Heating Sound Absorbing Thermal Insulation Material Foamed Polystyrene / Foamed Polyethylene Foamed Polystyrene / Foamed Polyethylene Air Filter Resin Net (Washable) Resin Net (Washable) Machine Weight (Mass) Lbs (kg) 31 (14) 31 (14) Piping Connections Notes: Liquid Pipes in (mm) 1/4 (6.4) (Flare Connection) 3/8 (9.5) (Flare Connection) Gas Pipes in (mm) 1/2 (12.7) (Flare Connection) 5/8 (15.8) (Flare Connection) Drain Pipe in (mm) VP13 VP13 (External Dia. 11/16 (17.5) Internal Dia. 1/2 (12.7)) (External Dia. 11/16 (17.5) Internal Dia. 1/2 (12.7)) 4 Sound Level (H/L) db(a) 43/37 47/41 Safety Devices Fuse Fuse Refrigerant Control Electronic Expansion Valve Electronic Expansion Valve Connectable outdoor unit R-410A VRV Series R-410A VRV Series Standard Accessories Drawing No. Operation Manual, Installation Manual, Installation Panel, Paper Pattern for Installation, Insulation tape, Insulation Tube, Clamps, Screws. 1 Nominal cooling capacities are based on the following conditions: Return air temperature: 80 FDB, 67 FWB (27 CDB /19.4 CWB) Outdoor temperature: 95 FDB (35 CDB) Equivalent ref. piping length: 25ft (7.5 m) (Horizontal) 2 Nominal heating capacities are based on the following conditions: Return air temperature: 70 FDB (21 CDB). Outdoor temperature: 47 FDB, 43 FWB (8.3 CDB / 6 CWB) Equivalent ref. piping length: 25ft (7.5 m) (Horizontal) 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 Sound levels are measured under JIS conditions. 5 Refer to page 9 for Power Input. C: 3D075572A Operation Manual, Installation Manual, Installation Panel, Paper Pattern for Installation, Insulation tape, Insulation Tube, Clamps, Screws. FXAQ-PVJU 3

5 Dimensions 2. Dimensions FXAQ07PVJU/FXAQ09PVJU/FXAQ12PVJU Unit (in.) 3D075388A 4 FXAQ-PVJU

6 Dimensions FXAQ18PVJU Unit (in.) 3D075389A FXAQ-PVJU 5

7 Dimensions FXAQ24PVJU Unit (in.) 3D075390A 6 FXAQ-PVJU

8 Piping Diagrams 3. Piping Diagrams C: 4D034245F Model Gas Liquid FXAQ07PVJU/FXAQ09PVJU/ FXAQ12PVJU/FXAQ18PVJU 1/2 1/4 FXAQ24PVJU 5/8 3/8 FXAQ-PVJU 7

9 Wiring Diagrams 4. Wiring Diagrams FXAQ07PVJU/FXAQ09PVJU/FXAQ12PVJU/FXAQ18PVJU/FXAQ24PVJU 3D FXAQ-PVJU

10 Electric Characteristics 5. Electric Characteristics 4D Safety Devices Setting 250V / 3.15A FXAQ - PVJU C: 4D047085C FXAQ-PVJU 9

11 Capacity Tables 7. Capacity Tables 7.1 Cooling Capacity FXAQ-P [Cooling capacity] Unit size Indoor air temp. Outdoor air temp. 61 FWB 64 FWB 67 FWB 70 FWB 72 FWB 75 FWB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC FDB MBh MBh MBh MBh MBh MBh MBh MBh MBh MBh MBh MBh TC: Total capacity: MBh SHC: Sensible heat capacity: MBh Refer to outdoor unit capacity tables for the actual performance data of each indoor and outdoor unit combination. 10 FXAQ-PVJU

12 Capacity Tables 7.2 Heating Capacity FXAQ-P [Heating capacity] Unit size Indoor air temp. Outdoor air temp. 62 FDB 65 FDB 68 FDB 70 FDB 72 FDB 75 FDB TC TC TC TC TC TC FDB FWB MBh MBh MBh MBh MBh MBh TC: Total capacity: MBh Refer to outdoor unit capacity tables for the actual performance data of each indoor and outdoor unit combination. FXAQ-PVJU 11

13 Air Velocity and Temperature Distributions (Reference Data) 8. Air Velocity and Temperature Distributions (Reference Data) FXAQ07PVJU <Cooling mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ07PVJU <Heating mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ-PVJU

14 Air Velocity and Temperature Distributions (Reference Data) FXAQ09PVJU <Cooling mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ09PVJU <Heating mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ-PVJU 13

15 Air Velocity and Temperature Distributions (Reference Data) FXAQ12PVJU <Cooling mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ12PVJU <Heating mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ-PVJU

16 Air Velocity and Temperature Distributions (Reference Data) FXAQ18PVJU <Cooling mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ18PVJU <Heating mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ-PVJU 15

17 Air Velocity and Temperature Distributions (Reference Data) FXAQ24PVJU <Cooling mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ24PVJU <Heating mode> AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS C: 3D FXAQ-PVJU

18 Sound Levels (Reference) 9. Sound Levels (Reference) 9.1 Overall Location of microphone Model 208/230V, 60Hz H L FXAQ07PVJU FXAQ09PVJU FXAQ12PVJU FXAQ18PVJU FXAQ24PVJU db(a) Notes: 1. The operating conditions are assumed to be standard (JIS conditions). Power source 208/230V, 60Hz. 2. The operating values were obtained in an anechoic chamber (conversion values). 3. Sound levels will vary depending on a range of factors such as the construction (acoustic absorption coefficient) of the particular room in which the equipment is installed. 9.2 Octave Band Level FXAQ07PVJU 208/230V, 60Hz FXAQ09PVJU 4D D FXAQ-PVJU 17

19 Sound Levels (Reference) FXAQ12PVJU FXAQ18PVJU 4D D FXAQ24PVJU 4D FXAQ-PVJU

20 Installation 10.Installation Safety ConsiderationsRead these SAFETY CONSIDERATIONS for Installation carefully before installing an air conditioner or heat pump. After completing the installation, make sure that the unit operates properly during the startup operation. Instruct the customer on how to operate and maintain the unit. Inform customers that they should store this Installation Manual with the Operation Manual for future reference. Always use a licensed installer or contractor to install this product. Improper installation can result in water or refrigerant leakage, electrical shock, fire, or explosion. Meanings of DANGER, WARNING, CAUTION, and NOTE Symbols: DANGER... Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING... Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION... Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTE... Indicates situations that may result in equipment or property-damage accidents only. DANGER Refrigerant gas is heavier than air and replaces oxygen. A massive leak can lead to oxygen depletion, especially in basements, and an asphyxiation hazard could occur leading to serious injury or death. Do not ground units to water pipes, gas pipes, telephone wires, or lightning rods as incomplete grounding can cause a severe shock hazard resulting in severe injury or death. Additionally, grounding to gas pipes could cause a gas leak and potential explosion causing severe injury or death. If refrigerant gas leaks during installation, ventilate the area immediately. Refrigerant gas may produce toxic gas if it comes into contact with fire. Exposure to this gas could cause severe injury or death. After completing the installation work, check that the refrigerant gas does not leak throughout the system. Do not install unit in an area where flammable materials are present due to risk of explosions that can cause serious injury or death. Safely dispose all packing and transportation materials in accordance with federal/state/local laws or ordinances. Packing materials such as nails and other metal or wood parts, including plastic packing materials used for transportation may cause injuries or death by suffocation. Only qualified personnel must carry out the installation work. Installation must be done in accordance with this installation manual. Improper installation may result in water leakage, electric shock, or fire. When installing the unit in a small room, take measures to keep the refrigerant concentration from exceeding allowable safety limits. Excessive refrigerant leaks, in the event of an accident in a closed ambient space, can lead to oxygen deficiency. Use only specified accessories and parts for installation work. Failure to use specified parts may result in water leakage, electric shocks, fire, or the unit falling. Install the air conditioner or heat pump on a foundation strong enough that it can withstand the weight of the unit. A foundation of insufficient strength may result in the unit falling and causing injuries. Take into account strong winds, typhoons, or earthquakes when installing. Improper installation may result in the unit falling and causing accidents. Make sure that a separate power supply circuit is provided for this unit and that all electrical work is carried out by qualified personnel according to local. state, and national regulations. An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire. Make sure that all wiring is secured, that specified wires are used, and that no external forces act on the terminal connections or wires. Improper connections or installation may result in fire. When wiring, position the wires so that the terminal box lid can be securely fastened. Improper positioning of the terminal box lid may result in electric shocks, fire, or the terminals overheating. Before touching electrical parts, turn off the unit. This equipment can be installed with a Ground-Fault Circuit Breaker (GFCI). Although this is a recognized measure for additional protection, with the earthing system in North America, a dedicated GFCI is not necessary. Securely fasten the outside unit terminal cover (panel). If the terminal cover/panel is not installed properly, dust or water may enter the outside unit causing fire or electric shock. When installing or relocating the system, keep the refrigerant circuit free from substances other than the specified refrigerant (R-410A) such as air. Any presence of air or other foreign substance in the refrigerant circuit can cause an abnormal pressure rise or rupture, resulting in injury. Do not change the setting of the protection devices. If the pressure switch, thermal switch, or other protection device is shorted and operated forcibly, or parts other than those specified by Daikin are used, fire or explosion may occur. FXAQ-PVJU 19

21 Installation Do not touch the switch with wet fingers. Touching a switch with wet fingers can cause electric shock. Do not allow children to play on or around the unit to prevent injury. The heat exchanger fins are sharp enough to cut. To avoid injury wear gloves or cover the fins while working around them. Do not touch the refrigerant pipes during and immediately after operation as the refrigerant pipes may be hot or cold, depending on the condition of the refrigerant flowing through the refrigerant piping, compressor, and other refrigerant cycle parts. Your hands may suffer burns or frostbite if you touch the refrigerant pipes. To avoid injury, give the pipes time to return to normal temperature or, if you must touch them, be sure to wear proper gloves. Install drain piping to proper drainage. Improper drain piping may result in water leakage and property damage. Insulate piping to prevent condensation. Be careful when transporting the product. Do not turn off the power immediately after stopping operation. Always wait for at least 5 minutes before turning off the power. Otherwise, water leakage may occur. Do not use a charging cylinder. Using a charging cylinder may cause the refrigerant to deteriorate. Refrigerant R-410A in the system must be kept clean, dry, and tight. (a) Clean and Dry -- Foreign materials (including mineral oils such as SUNISO oil or moisture) should be prevented from getting into the system. (b) Tight -- R-410A does not contain any chlorine, does not destroy the ozone layer, and does not reduce the earth s protection again harmful ultraviolet radiation. R-410A can contribute to the greenhouse effect if it is released. Therefore take proper measures to check for the tightness of the refrigerant piping installation. Read the chapter Refrigerant Piping and follow the procedures. Since R-410A is a blend, the required additional refrigerant must be charged in its liquid state. If the refrigerant is charged in a state of gas, its composition can change and the system will not work properly. The indoor unit is for R-410A. See the catalog for indoor models that can be connected. Normal operation is not possible when connected to other units. Remote controller (wireless kit) transmitting distance can be shorter than expected in rooms with electronic fluorescent lamps (inverter or rapid start types). Install the indoor unit far away from fluorescent lamps as much as possible. Indoor units are for indoor installation only. Outdoor units can be installed either outdoors or indoors. This unit is for indoor use. Do not install the air conditioner or heat pump in the following locations: (a) Where a mineral oil mist or oil spray or vapor is produced, for example, in a kitchen. Plastic parts may deteriorate and fall off or result in water leakage. (b) Where corrosive gas, such as sulfurous acid gas, is produced. Corroding copper pipes or soldered parts may result in refrigerant leakage. (c) Near machinery emitting electromagnetic waves. Electromagnetic waves may disturb the operation of the control system and cause the unit to malfunction. (d) Where flammable gas may leak, where there is carbon fiber, or ignitable dust suspension in the air, or where volatile flammables such as thinner or gasoline are handled. Operating the unit in such conditions can cause a fire. Take adequate measures to prevent the outside unit from being used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunctions, smoke, or fire. Instruct the customer to keep the area around the unit clean. Install the power supply and control wires for the indoor and outdoor units at least 3.5 feet away from televisions or radios to prevent image interference or noise. Depending on the radio waves, a distance of 3.5 feet may not be sufficient to eliminate the noise. Dismantling the unit, treatment of the refrigerant, oil and additional parts must be done in accordance with the relevant local, state, and national regulations. Do not use the following tools that are used with conventional refrigerants: gauge manifold, charge hose, gas leak detector, reverse flow check valve, refrigerant charge base, vacuum gauge, or refrigerant recovery equipment. If the conventional refrigerant and refrigerator oil are mixed in R-410A, the refrigerant may deteriorate. This air conditioner or heat pump is an appliance that should not be accessible to the general public. As design pressure is 478 psi, the wall thickness of field-installed pipes should be selected in accordance with the relevant local, state, and national regulations. 20 FXAQ-PVJU

22 Installation 2. BEFORE INSTALLATION When moving the unit while removing it from the packing case, be sure to lift it by the four hanger brackets. Aboid putting any pressure on other parts, especially, holizontal flaps, the refrigerant piping, drain piping, and other resin parts. Be sure to remove a cushion (corrugated paper) located between the heat exchanger and the right air filter. Be sure to check the type of R410A refrigerant to be used before installing the unit. (Using an incorrect refrigerant will prevent normal operation of the unit.) The accessories needed for installation must be retained in your custody until the installation work is completed. Do not discard them! Decide upon a line of transport. Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is unavoidable, use a sling of soft material or protective plates together with a rope when lifting, to avoid damage or scratches to the unit. For the installation of an outdoor unit, refer to the installation manual attached to the outdoor unit. When using the wireless remote controller, refer to the installation manual attached to the wireless remote controller. Do not install or operate the unit in rooms mentioned below. Laden with mineral oil, or filled with oil vapor or spray like in kitchens. (Plastic parts may deteriorate which could eventually cause the unit to fall out of place, or could lead to leaks.) Where corrosive gas like sulfurous gas exists. (Copper tubing and brazed spots may corrode which could eventually lead to refrigerant leaks.) Where machines can generate electromagnetic waves. (Control system may malfunction.) Where the air contains high levels of salt such as that near the ocean and where voltage fluctuates greatly such as that in factories. Also in vehicles or vessels. This unit, both indoor and outdoor, is suitable for installation in a commercial and light industrial environment. If installed as a household appliance it could cause electromagnetic interference. WARNING Entrust installation to the place of purchase or an authorized serviceman. Improper installation could lead to leaks and, in worse cases, electric shock of fi re. Use of unspecifi ed parts could lead to the unit falling, leaks and, in worse cases, electric shock or fi re. NOTE Be sure to read this manual before installing the indoor unit. FXAQ-PVJU 21

23 Installation 10.1 Accessories Check the following accessories are included with your unit. Name Quantity (1) Installation panel 1 set (2) Attachment screws for the installation panel 8 pcs. FXAQ07, 09, 12 type 9 pcs. FXAQ18, 24 type (3) Paper pattern for installation (4) Insulating tape 1 pc. 1 pc. Shape M4 25L Name (5) Clamp (6) Securing screws (7) Insulating tube Quantity 1 large 4 small 2 pcs. 1 long 1 short Shape (Other) Operation manual Installation manual M4 12L 2-2 OPTIONAL ACCESSORIES Remote controller type Wired type Wireless type Model BRC1E71 BRC7E FXAQ-PVJU

24 Installation FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONSTRUCTION AND CHECK AFTER INSTALLATION IS FINISHED. 1. Items to be checked after completion of work Items to be checked If not properly done, what is likely to occur Check Are the indoor and outdoor unit fi xed firmly? The units may drop, vibrate or make noise. Is the gas leak test fi nished? It may result in insufficient cooling. Is the unit fully insulated? Condensate water may drip. Does drainage fl ow smoothly? Condensate water may drip. Does the power supply voltage correspond to that shown on the name plate? Are wiring and piping correct? Is the unit safely grounded? Is wiring size according to specifi cations? Is something blocking the air outlet or inlet of either the indoor or outdoor units? Are refrigerant piping length and additional refrigerant charge noted down? The unit may malfunction or the components burn out. The unit may malfunction or the components burn out. It may be dangerous at electric leakage. The unit may malfunction or the components burn out. It may result in insufficient cooling. The refrigerant charge in the system is not clear. 2. Items to be checked at time of delivery * Also review the SAFETY CONSIDERATIONS Items to be checked Did you explain about operations while showing the operation manual to your customer? Did you hand the operation manual over to your customer? Check 2-3 NOTE TO THE INSTALLER Be sure to instruct customers how to properly operate the unit (especially cleaning filters, operating different functions, and adjusting the temperature) by having them carry out operations themselves while looking at the manual. 3. SELECTING INSTALLATION SITE (1) Select an installation site where the following conditions are fulfilled and that meets with your customer s approval. In the upper space (including the back of the ceiling) of the indoor unit where there is no possible dripping of water from the refrigerant pipe, drain pipe, water pipe, etc. Where the wall is strong enough to bear the indoor unit weight. Where suffi cient clearance for installation and maintenance can be ensured. (Refer to Fig. 1 and Fig. 2) Where optimum air distribution can be ensured. Where nothing blocks the air passage. Where condensate can be properly drained. Where the wall is not signifi cantly tilted. FXAQ-PVJU 23

25 Installation Where piping between indoor and outdoor units is possible within the allowable limit. (Refer to the installation manual of the outdoor unit.) Install the indoor and outdoor units, power supply wiring and connecting wires at least 3.5ft. away from televisions or radios in order to prevent image interference or noise. (Depending on the radio waves, a distance of 3.5ft. may not be sufficient enough to eliminate the noise.) Where the cool (warm) air reaches all across the room. [ Space required for installation (in.) ] /8 1-1/4 Obstruction 4-3/4 Fig (from floor) For installation in high places. Floor Fig. 2 (2) Consider whether the place where the unit will be installed can support the full weight of the unit, and reinforce it with boards and beams, etc. if needed before proceeding with the installation. Also, reinforce the place to prevent vibration and noise before installing. (The installation pitch can be found on the paper pattern for installation (3), so refer to it when considering the necessity for reinforcing the location.) (3) The indoor unit may not be directly installed on the wall. Use the attached installation panel (1) before installing the unit. DANGER Do not install unit in an area where fl ammable materials are present due to risk of explosion resulting in serious injury or death. WARNING If the supporting structural members are not strong enough to take the unit s weight, the unit could fall out of place and cause serious injury. 24 FXAQ-PVJU

26 Installation 10.2 Indoor Unit Installation Use only accessories and parts which are of the designated specifi cation when installing. CAUTION Install so that the unit does not tilt to either side or forward. Do not hold the unit by the horizontal fl aps when lifting it. (This may damage the horizontal fl aps.) (1) Open the piping through-hole. The refrigerant pipe and drain pipe can be passed out in one of 5 directions: left, bottom-left, backleft, bottom-right, and back-right. (Refer to Fig. 3) Using the paper pattern for installation (3), choose where to pass the piping out and open a throughhole (φ3-1/8 ) in the wall. Open the hole so that there is a downward slope for the drain piping. (See 6. DRAIN PIPING WORK ) (2) Remove the installation panel (1) from the unit and attach to the wall. (The installation panel is temporarily attached to the unit with a screw. (In case of 07, 09, 12 type)) (Refer to Fig. 3) (a) Check the location for the hole using the included paper pattern for installation (3). Choose a location so that there is at least a 3-1/2 gap between the ceiling and the main unit. (b) Temporarily attach the installation panel (1) at the temporary-securing position on the paper pattern for installation (3) and use a level to make sure the drain hose is either level or tilted slightly downward. (c) Secure the installation panel (1) to the wall using either screws or bolts. If using the attachment screws for the installation panel (2), attach using at least 4 screws on either side (for a total of 8 screws (07, 09, 12 type), 9 screws (18, 24 type)) of the recommended installation cleat position on the included paper pattern for installation (3). If using bolts, attach using a M8 - M10 bolt or equivalent (for a total of 2 bolts) on either side. If dealing with concrete, use commercially available foundation bolts (M8 - M10 or equivalent). (3) If using the left, bottom-left, or bottom-right positions for the piping, cut out the through-hole for the piping in the front grille. (Refer to Fig. 4) Installation panel (1) Temporary screw (In case of 07, 09, 12 type) Left pipe Front grille Cut out along the groove. Back-left pipe Bottom-left pipe Cut away Back-right pipe Fig. 3 Bottom-right pipe Fig. 4 FXAQ-PVJU 25

27 Installation (4) Making sure not to catch the horizontal flaps, remove the front grille by pulling in the direction of the arrow. Tab position Tab position Tab (3) (3) (3) Screw position Front grille (4) (2) (2) (2) Screw position (In case of 18, 24 type) Fig. 7 Remove the drain plug, the insulation tube, and the drain hose from the drain pan and replace. (Refer to Fig. 8) Connect the local refrigerant piping ahead of time, matching it to the liquid pipe and gas pipe marks engraved on the installation panel (accessory) (1). < Replacing the drain hose and drain plug > (1) Remove the drain plug and insulation tube. (2) Remove the drain hose and replace onto the left side. (3) Replace the drain plug and the insulation tube onto the right side. Insulating tube Drain plug Make sure there are no gaps. Fig. 8 Do not place lubricant (refrigerant oil) when inserting. This may cause deterioration and water leaks. Insert using a hexagon wrench (4mm). 26 FXAQ-PVJU

28 Installation (6) Hook the indoor unit onto the installation panel. (Refer to Fig. 9) Placing buffering material between the wall and the indoor unit at this time will make work easier. Control box cover Front panel Hook the indoor unit hook onto the installation panel (1). Front grille Place buffering material Be sure to pass all wires through the wiring guide. Refrigerant piping Tab (There are 2 places.) Wiring (locally procured) Transmission wiring, Remote controller wiring Fig. 9 Wall Power supply wiring, Ground wiring Conduit Installation panel (accessory) (1) For bottom-right and back-right piping Pass the drain hose and the refrigerant piping to the wall. (7) Pass power supply wiring and ground wiring threaded through conduit (For connecting the conduit to the unit, see 8-1 HOW TO CONNECT WIRINGS ), and remote controller wiring through the wiring guide in through the back of the indoor unit and to the front. (8) Connect the piping. (See 5. REFRIGERANT PIPING WORK and Fig. 10) Secure with vinyl tape. Refrigerant piping Drain hose Transmission wiring and remote controller wiring Refrigerant piping Conduit A A arrow view Transmission wiring and remote controller wiring Seal with putty corking material. Fig. 10 Wrap the insulating tape overlapping at least half the width with each wrap. Wrap the insulating tape all the way to the L-shaped bend. Seal the piping through-hole with putty corking material. FXAQ-PVJU 27

29 Installation (9) Push on both bottom edges of the indoor unit using both hands and hook the tab on the back of the indoor unit onto the installation panel (1). (Refer to Fig. 9) At this time remove the buffering material placed in step (6). Make sure power supply wiring, transmission wiring, ground wiring and remote controller wiring are not caught inside the indoor unit. When screwing in the indoor unit Installation panel Remove the front grille. (Refer to Fig. 7) Secure the indoor unit to the installation panel (1) with the securing screws (6). (Refer to Fig. 11) (accessory) (1) Refrigerant piping Insulating tape (accessory) (4) Fig. 11 M4 12L (accessory) (6) 5. REFRIGERANT PIPING WORK For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit. Execute heat insulation work completely on both sides of the gas piping and the liquid piping. Otherwise, a water leakage can result sometimes. (When using a heat pump, the temperature of the gas piping can reach up to approximately 250 F, so use insulation which is suffi ciently resistant.) Also, in cases where the temperature and humidity of the refrigerant piping sections might exceed 86 F or RH80 %, reinforce the refrigerant insulation. ( or thicker) Condensation may form on the surface of the insulating material. Before refrigerant piping work, check which type of refrigerant is used. Proper operation is not possible if the types of refrigerant are not the same. DANGER Refrigerant gas may produce toxic gas if it comes in contact with fire such as from a fan, heater, stove or cooking device. Exposure to this gas could result in severe injury or death. NOTE Use a pipe cutter and fl are suitable for the type of refrigerant. To prevent dust, moisture or other foreign matter from infiltrating the tube, either pinch the end or cover it with tape. Do not allow anything other than the designated refrigerant to get mixed into the refrigerant circuit, such as air, etc. If any refrigerant gas leaks while working on the unit, ventilate the room thoroughly right away. 28 FXAQ-PVJU

30 Installation The outdoor unit is charged with refrigerant. Use copper alloy seamless pipes. Be sure to use both a spanner and torque wrench together, as shown in the drawing, when connecting or disconnecting pipes to/from the unit. (Refer to Fig. 12) Refer to Table 1 for the dimensions of fl are. When connecting the fl are nut, coat the fl are section with ester oil or ether oil, rotate three or four times fi rst, then screw in. (Refer to Fig. 13) CAUTION Over-tightening may cause the fl are nuts to crack or the refrigerant to leak. Use the flare nut included with the unit. Refer to Table 1 for tightening torque. Torque wrench Spanner Piping union Flare nut Fig. 12 Ester oil or ether oil Fig. 13 Table 1 Pipe size Tightening torque (ft-lbf) Flare dimensions A (in.) Flare shape (in.) φ 1/ φ 3/ φ 1/ φ 5/ ±2 90 ±2 A R Not recommended but in case of emergency You must use a torque wrench but if you are obliged to install the unit without a torque wrench, you may follow the installation method mentioned below. After the work is finished, make sure to check that there is no gas leak. When you keep on tightening the fl are nut with a spanner, there is a point where the tightening torque suddenly increases. From that position, further tighten the flare nut the angle shown below: Table 2 Pipe size (in.) Further tightening angle Recommended arm length of tool (in.) φ 1/4 60 to 90 degrees Approx. 5-7/8 φ 3/8 60 to 90 degrees Approx. 7-7/8 φ 1/2 30 to 60 degrees Approx. 9-13/16 φ 5/8 30 to 60 degrees Approx /16 CAUTION CAUTION TO BE TAKEN WHEN BRAZING REFRIGERANT PIPING Do not use fl ux when brazing refrigerant piping. Therefore, use the phosphor copper brazing filter metal (BCuP) which does not require fl ux. (Flux has an extremely negative effect on refrigerant piping systems. For instance, if chlorine based flux is used, it will cause pipe corrosion. If the flux contains fluorine, it will damage the refrigerant oil.) FXAQ-PVJU 29

31 Installation When brazing the refrigerant piping, only begin brazing after having carried out nitrogen substitution (NOTE 1) or while inserting nitrogen into the refrigerant piping (NOTE 2). Once this is done, connect the indoor unit with a fl ared or a fl anged connection. DANGER Use of oxygen may cause an explosion resulting in serious injury or death. Only use nitrogen gas NOTE Refer to the Manual for Multi Installation for Buildings for directions on how to carry out nitrogen substitution. (Inquire with your dealer.) Nitrogen should be set to 2.9 psi with a pressure-reducing valve if brazing while inserting nitrogen into the piping. (Refer to Fig. 14) Refrigerant piping Part to be brazed Taping hands valve Pressure-reducing valve Nitrogen Nitrogen Fig. 14 After checking for gas leaks, be sure to insulate the pipe connections using the supplementary piping insulation tubing and insulating tape (4). The insulating tape (4) should be wrapped from the L-shaped bend all the way to the end inside the unit. (Refer to Fig. 15) Local piping Insulating tubing tape Clamping material large (accessory) (5) Insulating tubing tape Indoor unit piping insulation tubing Insulating tubing tape Indoor unit piping Indoor unit piping insulation tubing Insulating tape (accessory) (4) See 4. INDOOR UNIT INSTALLATION L-shaped bend Start wrapping Insulation tubing seam Attach the insulation tubing tape so that there are no gaps in the insulation tubing seam. Fig. 15 CAUTION Be sure to insulate any fi eld piping all the way to the piping connection inside the unit. Any exposed piping may cause condensate or burns if touched. 30 FXAQ-PVJU

32 Installation 10.3 Drain Piping Work 6. DRAIN PIPING WORK (1) Install the drain piping. (Refer to Fig. 16) The drain pipe should be short with a downward slope and should prevent air pockets from forming. Watch out for the points in the fi gure 16 when performing drain work. Make sure the drain hose is at a downward slope. Drain hose (Downward slope) Drain hose Make sure the tip does not go underwater even when water is added. Fig. 16 When extending the drain hose, use a commercially available drain extension hose, and be sure to insulate the extended section of the drain hose which is indoors. (Refer to Fig. 17) Indoor unit drain hose Extension drain piping (commercially available) Insulating tube (commercially available) Insulating tape (accessory) (4) ( See 4. INDOOR UNIT INSTALLATION ) Fig. 17 Make sure the diameter of the extension drain piping is the same as the indoor unit drain hose (hard vinyl chloride, I.D. 9/16 ) or bigger. In case of converging multiple drain pipes, install them referring to Fig. 18. Select diameter of drain piping which adapts to the capacity of the unit connected. 4 or more Fig. 18 (Slope of at least 1/100) (2) Make sure the drain works properly. After drain work is complete, perform a drain check by opening the front panel, removing the air filter, pouring water into the drain pan, and making sure water fl ows smoothly out of the drain hose. (Refer to Fig. 19) Plastic container for pouring Drain pan Fig. 19 Make sure not to splash the water. CAUTION Drain Piping Connections: Do not connect the drain piping directly to sewage pipes that smell of ammonia. The ammonia in the sewage might enter the indoor unit through the drain pipes and corrode the heat exchanger.. Never allow water to collect on the drain pipe or it will cause blockage. FXAQ-PVJU 31

33 Installation 10.4 Electrical Wiring Work All field supplied parts and materials and electric works must conform to local codes. Use copper wire only. For electric wiring work, refer to also WIRING DIAGRAM attached to the unit. For remote controller wiring details, refer to the installation manual attached to the remote controller. All wiring must be performed by an authorized electrician. This system consists of multiple indoor units. Mark each indoor unit as unit A, unit B..., and be sure the terminal block wiring to the outdoor unit and B S unit is properly matched. If wiring and piping outdoor unit and indoor unit are mismatched, the system may cause a malfunction. A circuit breaker capable of shutting down power supply to the entire system must be installed. Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit, the capacity of the circuit breaker and switch, and wiring instructions. Be sure to ground the air conditioner. DANGER Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a severe shock hazard resulting in severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead to severe injury or death. 7-2 ELECTRICAL CHARACTERISTICS Units Power supply Fan motor Model Hz Volts Voltage range MCA MOP W FLA FXAQ07PVJU FXAQ09PVJU Max. 253 FXAQ12PVJU / Min. 187 FXAQ18PVJU FXAQ24PVJU MCA: Minimum Circuit Amps (A); W: Fan Motor Rated Output (W); MOP: Maximum Overcurrent Protective Device (A) FLA: Full Load Amps (A) 32 FXAQ-PVJU

34 Installation SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE Model FXAQ07PVJU Remote controller wiring Power supply wiring Transmission wiring Field fuses Size Wire Size FXAQ09PVJU Size must FXAQ12PVJU 15A comply with FXAQ18PVJU local codes. FXAQ24PVJU Allowable length of transmission wiring and remote controller wiring are as follows. (1) Outdoor unit - Indoor unit: Max. 3280ft. (Total wiring length: 6560ft.) (2) Indoor unit - Remote controller: Max. 1640ft. Insulated thickness: 1/16 or more AWG18-16 WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER HOW TO CONNECT WIRINGS Conduit for power supply wiring Unscrew and remove the conduit mounting plate from the control box. (Refer to Fig. 20) Fix a conduit to the plate with a lock nut and reattach them at original position. Conduit Lock nut <Back side> Conduit mounting plate Refrigerant piping Control box Screw <Front side> Fig. 20 Power supply wiring and ground wiring Unscrew and remove the control box cover. Thread the power supply wiring and ground wiring through the included insulating tube (short) (7) and secure them with the included clamp (small) (5). (Refer to Fig. 21) Connect the power supply wiring and ground wiring to the power supply terminal block (3P). When doing this, firmly secure using the included clamp (small) (5) according to the fi gure. (Refer to Fig. 22) FXAQ-PVJU 33

35 Installation To avoid a short circuit in the control box, be sure to apply sealing material or putty (not included) to the wiring hole to prevent the infi ltration of water as well as insects or other small creatures. Otherwise a short-circuit may occur inside the control box. CAUTION When clamping the wirings, be sure no tension is applied to the wire connections by using the included clamp. Also, when wiring, make sure the cover on the control box fits snugly by arranging the wirings neatly and attaching the control box cover firmly. When attaching the control box cover, make sure no wirings get caught in the edges. Pass wiring through holes to prevent damage to them. Make sure the remote controller wiring and transmission wiring between the units, and other electrical wiring do not pass through the same locations outside the unit, separating them by at least 5, otherwise electrical noise (external static) could cause incorrect operation or breakage. Use only specifi ed wire and tightly connect wires to terminals. Be careful wires do not place external stress on terminals. Keep wiring in neat order and so as not to obstruct other equipment such as popping open the control box cover. Make sure the cover closes tight. Incomplete connections could result in overheating, and in worse case, electric shock or fire. [ PRECAUTIONS ] 1. Use round crimp-style terminals for connecting wires to the power supply terminal block. (Refer to Fig. 23) If unavailable, observe the following points when wiring. Do not connect wires of different gauge to the same power supply terminal. (Looseness in the connection may cause overheating.) Use the specifi ed electric wire. Connect the wire securely to the terminal. Lock the wire down without applying excessive force to the terminal. (Tightening torque: 0.97ft.lbf ±10 %) Attach insulation sleeve Round crimp-style terminal Fig. 23 Electric wire Tightening torque for the terminal screws. Use the correct screwdriver for tightening the terminal screws. If the blade of screwdriver is too small, the head of the screw might be damaged, and the screw will not be properly tightened. If the terminal screws are tightened too hard, screws might be damaged. Refer to the table below for the tightening torque of the terminal screws. Terminal Size Tightening torque (ft-lbf) Remote controller, Transmission wiring and Forced off terminal block (6P) M Power supply and Ground terminal block (3P) M Do not connect wires of different gauge to the same ground terminal. Looseness in the connection may lessen protection. Keep transmission wiring at least 5 away from power supply wiring. The equipment may malfunction if subjected to electrical (external) noise. For remote controller wiring, refer to the INSTALLATION MANUAL OF REMOTE CONTROLLER attached to the remote controller. 34 FXAQ-PVJU

36 Installation WIRING EXAMPLE Fit the power supply wire of each unit with a switch and fuse as shown in the drawing. COMPLETE SYSTEM EXAMPLE (3 systems) Power supply Main switch Outdoor unit Power supply wiring Transmission and remote controller wiring Switch Fuse/Breaker B S unit (Only for Heat recovery system) Indoor unit Remote controller Fig When using 1 remote controller for 1 indoor unit. (Normal operation) Power supply Power supply Power supply Power supply 208/230V 208/230V 208/230V 208/230V 1 Outdoor unit Hz Control box 60Hz 60Hz 60Hz L1 L2 IN/D OUT/D F1 F2 F1 F2 No. 1 System L1 L2 L1 L2 L1 L2 L1 L2 Indoor unit A P1 P2 F1 F2 T1 T2 L1 L2 Indoor unit B P1 P2 F1 F2 T1 T2 L1 L2 Indoor unit C P1 P2 F1 F2 T1 T2 L1 L2 P1 P2 F1 F2 T1 T2 Most downstream indoor unit P1 P2 P1 P2 P1 P2 P1 P2 Fig. 25 FXAQ-PVJU 35

37 Installation 2. For group control or use with 2 remote controllers Power supply 208/230V 1 Outdoor unit 60Hz L1 L2 Control box IN/D OUT/D F1 F2 F1 F2 No. 2 System Note: It is not necessary to designate indoor unit address when using group control. The address is automatically set when power is activated. L1 L2 L1 L2 L1 L2 L1 L2 P1 P2 F1 F2 T1 T2 L1 L2 P1 P2 F1 F2 T1 T2 L1 L2 P1 P2 F1 F2 T1 T2 L1 L2 P1 P2 F1 F2 T1 T2 Most downstream indoor unit Indoor unit A Indoor unit B Indoor unit C P1 P2 P1 P2 P1 P2 For use with 2 remote controllers Fig When including BS unit Power supply 208/230V 1 60Hz L1 L2 Outdoor unit Control box IN/D OUT/D F1 F2 F1 F2 No. 3 System B S unit Control box Control box OUT/D IN/D OUT/D IN/D F1 F2 F1 F2 F1 F2 F1 F Indoor unit A L1 L2 P1 P2 F1 F2 T1 T2 P1 P2 Fig NOTE A single switch can be used to supply power to units on the same system. However, branch switches and branch circuit breakers must be selected carefully. Do not ground the equipment on gas pipes, water pipes or lightning rods, or crossground with telephones. Improper grounding could result in electric shock. 36 FXAQ-PVJU

38 Installation CONTROL BY 2 REMOTE CONTROLLERS (CONTROLLING 1 INDOOR UNIT BY 2 RE- MOTE CONTROLLERS) When using 2 remote controllers, one must be set to MAIN and the other to SUB. For details, refer to the installation manual attached to the remote controller. Wiring Method (See 7. ELECTRIC WIRING WORK ) (1) Remove the control box cover. (2) Add the remote control 2 (sub) to the terminal block (6P) for remote controller (P1, P2) in the control box. (There is no polarity.) (Refer to Fig. 26 and section 7-3 for the wiring size.) COMPUTERISED CONTROL (FORCED OFF AND ON/OFF OPERATION) (1) Wire specifi cations and how to perform wiring Connect the input from outside to terminals T1 and T2 of the terminal block (6P). F2 T1 T2 FORCED OFF Fig. 28 Input A Wire specification Gauge Length External terminal Sheathed vinyl cord or cable (2 wire) AWG18-16 Max. 328 ft. Contact that can ensure the minimum applicable load of 15V DC, 1 ma. (2) Actuation The following table explains FORCED OFF and ON/OFF OPERATIONS in response to Input A. FORCED OFF ON/OFF OPERATION Input ON stops operation (impossible by remote controllers). Input OFF ON turns ON unit. Input OFF enables control by remote controller. Input ON OFF turns OFF unit. (3) How to select FORCED OFF and ON/OFF OPERATION Turn the power on and then use the remote controller to select operation. Set the remote controller to the fi eld set mode. For details, refer to the HOW TO SET IN THE FIELD, in the remote controller manual. When in the fi eld set mode, select mode No. 12, then set the FIRST CODE (switch) NO. to 1. Then set SECOND CODE (position) NO. to 01 for FORCED OFF and 02 for ON/OFF OPERATION. (FORCED OFF at factory set) (Refer to Fig. 29) Field Settings Unit No 0 Mode a FIRST CODE NO. Setting Fig b SECOND CODE NO. CENTRALIZED CONTROL For centralized control, it is necessary to designate the group No. For details, refer to the manual of each optional controllers for centralized control. FXAQ-PVJU 37

39 Installation 10.5 Field Settings (1) Make sure the control box covers are closed on the indoor and outdoor units. (2) Field settings must be made from the remote controller in accordance with installation conditions. Settings can be made by changing the Mode No, FIRST CODE NO. and SECOND CODE NO.. Refer to the installation manual attached to the remote controller. The Field Settings included with the remote controller lists the order of the settings and method of operation. * Setting is made in all units in a group. To set for individual indoor units or to check the setting, use the mode Nos. (with 2 in upper digit) in parentheses ( ). SETTING AIR FILTER SIGN Remote controllers are equiped with liquid crystal display air filter signs to display the time to clean air filters. Change the SECOND CODE NO. according to Table 3 depending on the amount of dirt or dust in the room. (SECOND CODE NO. is factory set to 01 for air filter contamination-light) Table 3 Setting Air fi lter contamination-light Air fi lter contamination-heavy Spacing time of display air fi lter sign Mode No. FIRST CODE NO. SECOND CODE NO. Approx. 200 hours (20) 0 Approx. 100 hours 02 SETTING AIRFLOW RATE INCREASE MODE It is possible to raise set airfl ow (HIGH and LOW) from the field. Change the SECOND CODE NO. as shown in Table 4 to suit your needs. (SECOND CODE NO. is factory set to 01 for Standard.) Table 4 Setting Mode No. FIRST CODE NO. SECOND CODE NO. Standard 01 A little increase 13 (23) 0 02 Increase 02 When using wireless remote controllers When using wireless remote controllers, wireless remote controller address setting is necessary. Refer to the installation manual attached to the wireless remote controller for setting instructions. 38 FXAQ-PVJU

40 Test Run 11. Test Run Make sure the control box covers are closed on the indoor and outdoor units. Refer to the installation manual of the outdoor unit. The operation lamp of the remote controller will flash when a malfunction occurs. Check the malfunction code on the liquid crystal display to identify the point of trouble. An explanation of malfunction codes and the corresponding trouble is provided in the installation manual of the outdoor unit. If any of the items in Table 5 are displayed, there may be a problem with the wiring or power, so check the wiring again. Table 5 Remote controller display (under centralized control) is lit up U4 is lit up UH is lit up No display Content There is a short circuit at the FORCED OFF terminals (T1, T2). The power on the outdoor unit is off. The outdoor unit has not been wired for power supply. Incorrect wiring for the transmission wiring and/or FORCED OFF wiring. The transmission wiring is cut. The power on the indoor unit is off. The indoor unit has not been wired for power supply. Incorrect wiring for the remote controller wiring, the transmission wiring, and/or the FORCED OFF wiring. The remote controller wiring is cut. If U3 is lit up, the malfunction code shows the test run has not been performed yet. FXAQ-PVJU 39

41 Accessories 12.Accessories 12.1 Optional Accessories (For Controls) Refer to booklet of Controls. 40 FXAQ-PVJU

42 Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorized importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any inquiries, please contact your local importer, distributor and/or retailer. Daikin, Daikin AC Absolute Comfort, and its design, VRV, REFNET, and Quaternity are trademarks of Daikin Industries, LTD. All rights reserved. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO international standard for environment management. Dealer 1645 Wallace Drive, Suite 110 Carrollton, TX75006 info@daikinac.com c 2012 Daikin Industries, LTD. Specifications, designs and other content appearing in this brochure are current as of February 2012 but subject to change without notice. Printed in U.S.A. 02/12 FS.K

FXFQ-M Ceiling Mounted Cassette Type (Multi Flow)

FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) EDUS 39-600 - F1_a FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) AMERICAS EDUS39-600-F1_a FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) 1. External Appearance...2 2. Specifications...3 3. Dimensions...5

More information

EDUS F4. FXMQ-PBVJU Ceiling Mounted Duct Type

EDUS F4. FXMQ-PBVJU Ceiling Mounted Duct Type EDUS391503-F4 FXMQ-PBVJU Ceiling Mounted Duct Type EDUS391503-F4 FXMQ-PBVJU Ceiling Mounted Duct Type 1. Features and Benefits...2 2. Specifications...3 3. Dimensions...6 4. Piping Diagrams...11 5. Wiring

More information

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. Installation manual Manuel d installation Manual de instalación

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. Installation manual Manuel d installation Manual de instalación English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R40A Split Series Français Installation manual Manuel d installation Manual de instalación Español MODELS FTX30NVJU FTX36NVJU Contents Safety Considerations...

More information

EDUS F7. FXLQ-M / FXNQ-M Floor Standing Type / Concealed Floor Standing Type

EDUS F7. FXLQ-M / FXNQ-M Floor Standing Type / Concealed Floor Standing Type FXLQ-M / FXNQ-M Floor Standing Type / Concealed Floor Standing Type FXLQ-M / FXNQ-M Floor Standing Type / Concealed Floor Standing Type 1. Features and Benefits...2 1.1 FXLQ... 2 1.2 FXNQ... 3 2. Specifications...4

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Installation manual Manuel dinstallation Manual de instalación Français Español MODELS FTX09NMVJU FTX12NMVJU FTX15NMVJU FTX18NMVJU

More information

SYSTEM Inverter Air Conditioners READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

SYSTEM Inverter Air Conditioners READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE. INSTALLATION MANUAL SYSTEM Inverter Air Conditioners MODELS Ceiling-mounted Duct type FXMQ72MVJU FXMQ96MVJU English Français READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A

More information

SPLIT SYSTEM Air Conditioners. Read these instructions carefully before installation. Keep this manual in a handy place for future reference.

SPLIT SYSTEM Air Conditioners. Read these instructions carefully before installation. Keep this manual in a handy place for future reference. INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling mounted cassette type (Round flow model) FCQ18PAVJU FCQ24PAVJU FCQ30PAVJU FCQ36PAVJU FCQ42PAVJU English Français Español Read these instructions

More information

SPLIT SYSTEM Air Conditioners

SPLIT SYSTEM Air Conditioners INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODEL Ceiling suspended type FHQ24MVJU FHQ30MVJU FHQ36MVJU FHQ42MVJU Read these instructions carefully before installation. Keep this manual in a handy

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Français Español Installation manual Manuel dinstallation Manual de instalación MODELS FVXS09NVJU FVXS12NVJU FVXS15NVJU FVXS18NVJU

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Español Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Installation manual Manuel dinstallation Manual de instalación MODELS RX09RMVJU RX12RMVJU RX15RMVJU RX18RMVJU

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners INSTALLATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place

More information

SPLIT SYSTEM Air Conditioners

SPLIT SYSTEM Air Conditioners INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling-mounted Cassette type (Multi flow model) FCQ24MVJU FCQ30MVJU FCQ36MVJU FCQ42MVJU Read these instructions carefully before installation.

More information

INSTALLATION MANUAL R410A Split Series

INSTALLATION MANUAL R410A Split Series Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Installation manual Manuel dinstallation Manual de instalación MODELS FDMQ09RVJU FDMQ12RVJU FDMQ15RVJU FDMQ18RVJU

More information

DAIKIN AIR CONDITIONER

DAIKIN AIR CONDITIONER 3P226011-1A M07B242A DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Installation manual Manuel dinstallation Manual de instalación MODELS RX09NMVJU RX12NMVJU RX18NMVJU RX24NMVJU

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R40A Split Series Français Español Installation manual Manuel Manuel dinstallation dinstallation Manual de instalación MODELS FFQ09Q2VJU FFQ2Q2VJU

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R40A Split Series Español Installation manual Manuel dinstallation Manual de instalación MODELS MXS8NMVJU 3MXS4NMVJU 4MXS36NMVJU MXL8QMVJU

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners INSTALLATION MANUAL SYSTEM Inverter Air Conditioners English Español MODELS Ceiling mounted cassette type (Round flow model) FXFQ25PVE(9) FXFQ32PVE(9) FXFQ40PVE(9) FXFQ50PVE(9) FXFQ63PVE(9) FXFQ80PVE(9)

More information

INSTALLATION MANUAL FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU FBQ48PVJU. MODELS Ceiling-mounted Duct type

INSTALLATION MANUAL FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU FBQ48PVJU. MODELS Ceiling-mounted Duct type INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling-mounted Duct type FBQ18PVJU FBQ24PVJU FBQ30PVJU FBQ36PVJU FBQ42PVJU FBQ48PVJU English Français Read these instructions carefully before

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

INSTALLATION MANUAL FTQ18PBVJU FTQ24PBVJU FTQ30PBVJU FTQ36PBVJU FTQ42PBVJU. MODELS Air Handling Unit

INSTALLATION MANUAL FTQ18PBVJU FTQ24PBVJU FTQ30PBVJU FTQ36PBVJU FTQ42PBVJU. MODELS Air Handling Unit INSTALLATION MANUAL SPLIT SYSTEM HEAT PUMP MODELS Air Handling Unit FTQ18PBVJU FTQ24PBVJU FTQ30PBVJU FTQ36PBVJU FTQ42PBVJU English Français Español Read these instructions carefully before installation.

More information

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Español Français English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R40A Split Series Installation manual Manuel dinstallation Manual de instalación MODELS 5MXS48TVJU 4MXL36TVJU Contents Safety Considerations...

More information

III SYSTEM Air Conditioners

III SYSTEM Air Conditioners INSTALLATION MANUAL III SYSTEM Air Conditioners MODELS BSVQ36PVJU BSVQ60PVJU BSVQ96PVJU English Français Español Read these instructions carefully before installation. Keep this manual in a handy place

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL System air conditioners FXZQ07M7VJU FXZQ09M7VJU FXZQM7VJU FXZQ8M7VJU 5 6 7 8 9 0 x x 8x x x x x x x x x x x 5.8.8 5 ~ 5 6 7 8 5 59* 59* 59 7.6 ~6.6 00 8 6 7 9 F T T FORCED

More information

General safety precautions English

General safety precautions English English 1 1 Units are marked with the following symbol: 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in

More information

INSTALLATION MANUAL. Air Conditioners

INSTALLATION MANUAL. Air Conditioners INSTALLATION MANUAL SYSTEM Air Conditioners MODELS Ceiling Mounted Cassette type (Round Flow with Sensing) FXFQ25SVM FXFQ63SVM FXFQ32SVM FXFQ80SVM FXFQ40SVM FXFQ100SVM FXFQ50SVM FXFQ125SVM CAREFULLY READ

More information

FXOQ-M + BEQ-M Concealed Vertical Air-Handler Type

FXOQ-M + BEQ-M Concealed Vertical Air-Handler Type DACA FXOQ-M + BEQ-M Concealed Vertical Air-Handler Type AMERICAS 1645 Wallace Drive, Suite 110 Carrollton, TX75006 info@daikinac.com www.daikinac.com EDUS39-600-F5 Printed in U.S.A. 09/2006 K AK FS AMERICAS

More information

Safety Precautions (1)

Safety Precautions (1) 3P207257-3D M07B061D DAIKIN AIR CONDITIONER Two-dimensional bar code is a code for manufacturing. Safety Precautions (1) Read these Safety Precautions carefully to ensure correct installation. This manual

More information

FXZQ-M 4-Way Ceiling Mounted Cassette Unit (2' 2')

FXZQ-M 4-Way Ceiling Mounted Cassette Unit (2' 2') EDUS 39-800 - F9_b FXZQ-M 4-Way Ceiling Mounted Cassette Unit (' ') AMERICAS EDUS39-800-F9_b FXZQ-M 4-Way Ceiling Mounted Cassette Unit ( ). External Appearance.... Specifications...3 3. Dimensions...5

More information

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling-mounted duct type low static pressure unit FXDQ07MVJU FXDQ09MVJU FXDQ12MVJU FXDQ18MVJU FXDQ24MVJU Read these instructions carefully before

More information

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Manuel dinstallation Série split R410A Français Manual de instalación Serie Split R410A Español Models RXS15LVJU RXS18LVJU

More information

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English AIR CONDITIONER (SPLIT TYPE) Model name : TCB-DP22CUL 2 Air Conditioner (Split type) English Manuel D installation Climatiseur (Type split) 12 Français Please read this carefully before installing the

More information

General safety precautions English

General safety precautions English General safety precautions General safety precautions English 1 General safety precautions 1 General safety precautions Units are marked with the following symbol: 1.1 About the documentation The original

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

[FLARE CONNECTION TYPE] ATTENTION

[FLARE CONNECTION TYPE] ATTENTION SPLIT-TYPE AIR CONDITIONERS Model MXZ-2A20NA [FLARE CONNECTION TYPE] HFC utilized R410A INSTALLATION MANUAL ATTENTION This manual mentions how to install only the outdoor unit, MXZ-2A20NA. As for the way

More information

AIR CONDITIONER BRANCH BOX INSTALLATION MANUAL. For authorized service personnel only. [UTP-PY03A] [UTP-PY02A] PART NO.

AIR CONDITIONER BRANCH BOX INSTALLATION MANUAL. For authorized service personnel only. [UTP-PY03A] [UTP-PY02A] PART NO. AIR CONDITIONER BRANCH BOX INSTALLATION MANUAL For authorized service personnel only. [UTP-PY03A] [UTP-PY02A] Türkçe Pусский Português EλληvIkά Italiano Español Français Deutsch English PART NO. 9380120018-03

More information

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A. INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Français Manual de instalación Serie Split R410A Español Model RXS24LVJU Safety Precautions Read these Safety Precautions

More information

INSTALLATION MANUAL. English. Français. Español

INSTALLATION MANUAL. English. Français. Español INSTALLATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling Mounted Cassette type (Round Flow with Sensing Panel) FCQ18TAVJU FCQ24TAVJU FCQ30TAVJU FCQ36TAVJU FCQ42TAVJU FCQ48TAVJU Français Español

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS09LVJU FTXS12LVJU CTXS07LVJU

English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS09LVJU FTXS12LVJU CTXS07LVJU English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Français MODELS FTXS09LVJU FTXS12LVJU CTXS07LVJU Safety Precautions Read these Safety Precautions carefully to ensure

More information

Self Cleaning decoration panel

Self Cleaning decoration panel INSTALLATION MANUAL Decoration Provided with Filter Auto Cleaning Function Self Cleaning decoration panel Installation manual Self Cleaning decoration panel English BYCQ140CGW1 BYCQ140CGW1 Self Cleaning

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B OPERATION MANUAL System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B Air inlet (top of main unit) Air filter (Under the panel) Name plate (Indoor

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English Split-type Air-Conditioner MXZ-3B54VA MXZ-4B71VA INSTALLATION MANUAL English Refer to the installation manual of each indoor unit for indoor unit installation. IMPORTANT NOTES TO COMPLY WITH THE REQUIREMENTS

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1 INSTALLATION MANUAL Decoration Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ0D7GW BYCQ0D7GFW BYCQ0D7GW BYCQ0D7GFW Installation manual Contents. SAFETY PRECAUTIONS....

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2D52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

HEAT PUMP INSTALLATION MANUAL

HEAT PUMP INSTALLATION MANUAL DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL Models: TERRA09HP230V1A TERRA12HP230V1A TERRA18HP230V1B TERRA24HP230V1B Thank you for choosing a Gree Terra Ductless Heat Pump for your customer. Please

More information

INSTALLATION MANUAL. System Air Conditioner 3P H MODEL

INSTALLATION MANUAL. System Air Conditioner 3P H MODEL INSTLLTION MNUL System ir Conditioner MODEL REYQ7TTJU REYQ96TTJU REYQ0TTJU REYQTTJU REYQ68TTJU REYQ9TTJU REYQ6TTJU REYQ0TTJU REYQ6TTJU REYQ88TTJU REYQTTJU REYQ6TTJU REYQ60TTJU REYQ8TTJU REYQ08TTJU REYQTTJU

More information

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET AUTO COOL DRY MODE TIMER ON OFF TIMER OFF/ON TEMP ON TIMER FAN SPEED AIR SWING SET 1 2 3 FAN SPEED AIR SWING OFF CANCEL AC RC SET CHECK CLOCK RESET Order No: PAPAMY1611008CE Indoor Unit CS-MPS9SKH CS-MPS12SKH

More information

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only ED 40-437 Packaged Air Conditioners Duct Connection Type [50Hz] (Middle Static Pressure Application) FDMG-AV1(S) Series Cooling Only ED40-437 Duct Connection Type Middle Static Pressure Application [50Hz]

More information

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units Installation and Operation Manual CMA12SB-0 Series Horizontal/Side Discharge Condensing Units 517.787.2100 www.marsdelivers.com www.heatcontroller.com Heat Controller CONTENTS PAGE 1. PRES... 1 2. INSTALLATION

More information

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 SPLIT-TYPE AIR CONDITIONER CONTENTS INSTALLATION MANUAL 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2 Model MXZ-A26/32WV HFC utilized R410A 2. INSTALLATION DIAGRAM & ACCESSORIES... 2 3. SELECTING

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

BSV-P Centralized Branch Selector units

BSV-P Centralized Branch Selector units BSV-P Centralized Branch Selector units BSV4Q36PVJU BSV6Q36PVJU AMERICAS BSV-P Centralized Branch Selector units 1. Specifications...2 2. Dimensions...3 3. Piping Diagrams...5 4. Wiring Diagrams...7 5.

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

Installation Instructions

Installation Instructions 40MBD Ducted Style Ductless System Sizes 09 to 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2

More information

INSTALLATION MANUAL. Four-Way Cassette. Model B-VMH09CU-1 B-VMH12CU-1 B-VMH18CU

INSTALLATION MANUAL. Four-Way Cassette. Model B-VMH09CU-1 B-VMH12CU-1 B-VMH18CU INSTALLATION MANUAL Four-Way Cassette Model B-VMH09CU- B-VMHCU- B-VMH8CU- 57.787.00 www.marsdelivers.com If used as MULTI unit, please refer to the Installation & operation manuals packed with outdoor

More information

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский. DAIKIN ROOM AIR CONDITIONER Operation Manual FDXS25F2VEB FDXS60F2VEB FDXS35F2VEB FDXS50F2VEB English Deutsch Français Nederlands Español Italiano Ελληνικά Portugues Русский Türkçe CONTENTS READ BEFORE

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2C52VA Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 INSTALLATION, OPERATION & MAINTENANCE MANUAL InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

Installation Instructions

Installation Instructions 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes

More information

INSTALLATION MANUAL. AIR CONDITIONER Indoor Unit (Duct type) PART No Contents. En-1 1. SAFETY PRECAUTIONS WARNING

INSTALLATION MANUAL. AIR CONDITIONER Indoor Unit (Duct type) PART No Contents. En-1 1. SAFETY PRECAUTIONS WARNING AIR CONDITIONER Indoor Unit (Duct type) INSTALLATION MANUAL PART No. 93838647-03 [Original instructions] For authorized service personnel only. Contents. SAFETY PRES... 2. ABOUT THIS PRODUCT...2 2.. Precautions

More information

Installation Instructions

Installation Instructions 40MBCQ Cassette Ductless System Sizes 09 to 8 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS INDOOR... 5 CLEARANCES INDOOR...

More information

INSTALLATION MANUAL For authorized service personnel only.

INSTALLATION MANUAL For authorized service personnel only. AIR CONDITIONER INDOOR UNIT Ceiling type INSTALLATION MANUAL For authorized service personnel only. Contents 1. SAFETY PRES... 2 2. ABOUT THE UNIT... 2 2.1. Precautions for using R410A refrigerant 2.2.

More information

INSTALLATION MANUAL AIR CONDITIONER OUTDOOR UNIT. Contents. PART No English. Français. For authorized personnel only.

INSTALLATION MANUAL AIR CONDITIONER OUTDOOR UNIT. Contents. PART No English. Français. For authorized personnel only. AIR CONDITIONER OUTDOOR UNIT Français Español English INSTALLATION MANUAL For authorized personnel only. Contents 1. SAFETY PRECAUTIONS 2 2. ABOUT THE PRODUCT 2.1. Precautions for using R410A refrigerant

More information

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI MULTI DUCTLESS INVERTER HEAT PUMP PANEL CONSOLE TYPE INDOOR UNIT INSTALLATION MANUAL Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI Thank you for choosing a C&H Multi Ductless Heat Pump! You can feel confident

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS - Wall-mount indoor unit - OPERATING LIMITS Cooling Maximum conditions Heating Maximum conditions Outdoor temperature : 122 F (50 C) D.B. Outdoor temperature : 75 F (24 C) D.B.

More information

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79Y335H01 Model names are indicated in 1-3. When installing multi units, refer to the installation manual of the multi unit for outdoor

More information

AIR CONDITIONER OUTDOOR UNIT

AIR CONDITIONER OUTDOOR UNIT AIR CONDITIONER OUTDOOR UNIT INSTALLATION MANUAL For authorized personnel only. MANUEL D'INSTALLATION Pour le personnel agréé uniquement. English Français MANUAL DE INSTALACIÓN Solo para personal autorizado.

More information

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type. AIR CONDITIONER (MULTI TYPE) Indoor Unit Model name: 1-Way Cassette Type MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E English SMMS 1-Way Cassette SH Type SMMS 1-Way Cassette SH Type 1 Original instruction

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL MSZ-D30/36NA MSY-D30/36NA JG79A061H09 Phillips screwdriver Level Scale Utility knife or scissors 3 in. (75 mm) hole saw Torque wrench Wrench (or

More information

Installation Instructions

Installation Instructions 40MHH High Wall Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes only. Actual

More information

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CLM97 CLM7 CLM7 FILE NO. Destination: North America DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 9,700 BTU/h,00 BTU/h 0,600 BTU/h Outdoor Model No.

More information

Inverter Air Source Heat Pump Monobloc system

Inverter Air Source Heat Pump Monobloc system Inverter Air Source Heat Pump Monobloc system Product Data & Installation Manual AXAI-06M & AXAI-09M AXAI-12M & AXAI-15M TABLE OF CONTENT INSTRUCTIONS 1 This manual 1 Items inside product box. 2 Tools

More information

Split-type Air-Conditioner

Split-type Air-Conditioner Split-type Air-Conditioner MXZ-2E52VAD MXZ-3E54VAD MXZ-4E71VAD Installation Manual For INSTALLER This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL Model names are indicated in 1-3. JG79A145H05 Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench Wrench (or

More information

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector Issue 1 KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR Installation Manual Instructions for :- For safe and correct use please read the installation manuals supplied with the equipment.

More information

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Split-type Air-Conditioner MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Deutsch Français Nederlands Español Italiano

More information

AIR CONDITIONER FLOOR CEILING

AIR CONDITIONER FLOOR CEILING Installation manual ENGLISH AIR CONDITIONER FLOOR CEILING English Indoor unit floor ceiling type FCD / TCD /DCF IT IS MANDATORY TO CUT OFF POWER SUPPLY BEFORE STARTING TO WORK IN THE ELECTRIC CASING BOXES.

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Please read this manual carefully before installation and keep it for future reference. Installation Manual. Olympus Series Cassette Air Handlers

Please read this manual carefully before installation and keep it for future reference. Installation Manual. Olympus Series Cassette Air Handlers Please read this manual carefully before installation and keep it for future reference. Installation Manual Olympus Series Cassette Air Handlers The design and specifications are subject to change without

More information

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL MSZ-D30/36NA MSY-D30/36NA JG79A061H01 Phillips screwdriver Level Scale Utility knife or scissors 3 in. (75 mm) hole saw Torque wrench Wrench (or

More information

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump COMFORT...BUILT TO LAST 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump INSTALLATION MANUAL INDOOR UNIT: 1PAMSH09-SZW-14.5 1PAMSH09-SZW-15 1PAMSH12-SZW-15 1PAMSH18-SZW-15

More information

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL REFRIGERANT JG79B530H01 Model names are indicated in 1-3. Phillips screwdriver Level Scale Utility knife or scissors 75 mm hole saw Torque wrench

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information