Replacement Parts List
|
|
- Suzan Craig
- 6 years ago
- Views:
Transcription
1 Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET DS-07 COMPRESSORS 1 1 Compressor, H20J403DBLA Compressor, H20J403DBEA Compressor, H20J403DBFA MOUNTING COMPONENTS 2 1 Screw, Tapping, w/sleeve Grommet, Rubber CONDENSER FAN MOTORS 4 1 Blade, Fan, 24" Dia., 31 Deg Arm, Motor Mount Belly Band, Motor Mount Motor, Fan, 1/3HP, 208/ Motor, Fan, 1/3HP, Motor, Fan, 1/3HP, See Elec. Box 3 Capacitor, Run, 5.0/ MFD, 370V * Harness, Wire STANDARD INDOOR BLOWER MOTORS: 9TH CHARACTER = A THRU M 8 2 Motor, Blower, 2.0HP, 200/230/ Motor, Blower, 2.0HP, Sheave, Variable, 1Grv,.875 Bore Sheave, Fixed, 1 Grv, Bore HIGH STATIC INDOOR BLOWER MOTOR: 9TH CHARACTER = N THRU Z 8 2 Motor, Blower, 3.0HP, 200/230/ Motor, Blower, 3.0HP, Sheave, Variable, 1Grv,.875 Bore Sheave, Fixed, 1 Grv, Bore INDOOR BLOWERS: COMMON PARTS 14 2 Blower Rail, Blower Side Belt, V, A Arm, Blower Adjustment, Left, 7.5T Arm, Blower, Adjustment, Right, 7.5T * Key, Stl, 1/4 Sq. x Lg ** * Switch, Limit, 200 Manual of A-0605
2 BOX ELECTRIC: COOLING ONLY 16 3 Control, Simplicity, Lockout Circuit Breaker, 3.2A, 250V CB Terminal Block, 3P, 600V, 335A TB * Lug, Electrical GRND Contactor, Elec., 30Amp, 3P M1, Contactor, Elec., 20Amp, 2P M Contactor, Elec., 30Amp, 1P M Transformer,.075KVA, T Transformer,.075KVA, 460 T Transformer,.075KVA, 575 T * Control, Temp. Switch, SPST LAS * Control, Temp.SPST, 26F FS1, BOX ELECTRIC: GAS HEAT 16 3 Control, Simplicity, Lockout Circuit Breaker, 3.2A, 250V CB Terminal Block, 3P, 600V, 115A TB * Lug, Electrical GRND Contactor, Elec., 30Amp, 3P M1, Contactor, Elec., 20Amp, 2P M Contactor, Elec., 30Amp, 1P M Transformer,.075KVA, 208/230 T1, Transformer,.075KVA, 460PRI T1, Transformer, 575V, 75A T1, * Control, Temp. Switch, SPST LAS * Control, Temp., SPST, 26F FS1, Transformer, 460/ T Fuse, Dual, 50A, 600V FU1, BOX ELECTRIC: ELECTRIC HEAT 16 3 Control, Simplicity, Lockout Circuit Breaker, 3.2A, 250V CB Terminal Block, 3P, 600V, 335A TB * Lug, Electrical GRND Contactor, Elec., 30Amp, 3P M1, Contactor, Elec., 20Amp, 2P M Contactor, Elec., 30Amp, 1P M Transformer,.075KVA, 208/230 T Transformer,.075KVA, 460 T Transformer,.075KVA, 575 T * Control, Temp., Switch, SPST, 55/45 LAS * Control, Temp. Switch, SPST, 26F FS1, A of 20
3 EVAPORATOR COIL 27 1 Coil, Evaporator, 3Rx32x Distributor, 7Tube, # Distributor, 8Tube, # * Header, Evap, Sys * Header, Evap, Sys Pan, Drain Pan, Drain, SS CONDENSER COIL 31 1 Coil, Condenser, Sys. 2 (Sloped) * Header, Cond, DIS, S * Header, Cond, RET, S1&S Coil, Condenser, Sys. 1(Vertical) * Header, Condenser, DIS, S * Header, Condenser, RET, S1&S PIPING 34 1 Switch, Low Press., 7Open/22Close Switch, Pressure, 405 PSIG Filter, Solid * Core, V Port * Cap, Seal Muffler, Discharge HEAT SECTION: NO HEAT / ELECTRIC HEAT * Harness, Jumper GAS HEAT 37 4 Heat Exchanger, 4Tube, Al * Baffle, Heat Exch. Tube, AL only Heat Exchanger, 4Tube, SS Heat Exchanger, 6Tube, Al * Baffle, Heat Exch. Tube, AL only Heat Exchanger, 6Tube, SS Plate, Balance, 4Tube, Al Plate, Balance, 4Tube, SS Plate, Balance, 6Tube, Al Plate, Balance, 6Tube, SS Control, Ignition Cover, Ignition Control Switch, Limit, Plate, Shoot Through Bracket, Burner Burner Valve, Gas Bracket, Manifold Manifold of A-0605
4 GAS HEAT (CONTINUED) 48 4 Igniter Orifice, Gas Sensor, Flame Shield, Air Switch, Limit, 300 Manual Screen, Vent Pipe 98970** Vent Pipe, Al Vent Pipe, SS Blower, Combustion, w/motor Switch, Pressure * Pressure Tap ELECTRIC HEAT * Heater Element, V, 09KW ** * Heater Element, V, 18KW ** * Heater Element, V, 24KW ** * Heater Element, V, 36KW ** * Heater Element, 460V, 09KW ** * Heater Element, 460V, 18KW ** * Heater Element, 460V, 24KW ** * Heater Element, 460V, 36KW ** * Heater Element, 575V, 09Kw ** * Heater Element, 575V, 18Kw ** * Heater Element, 575V, 24Kw ** * Heater Element, 575V, 36Kw ** CONVENIENCE OUTLET - 11TH CHARACTER = A, B, E, F, G, H, L, R * Cover Plate, Outlet NON-POWERED CONVENIENCE OUTLET - 11TH CHARACTER = C, D, J, K, M, N, P, Q 57 5 Outlet, Convenience * Switch, Toggle, 30Amp, 600V Cover, Switchplate POWERED CONVENIENCE OUTLET - 11 CHARACTER = S, T, U, V, W, X, Y, Z 57 5 Outlet, Convenience * Switch, Toggle, 30Amp, 600V Cover, Switch, Plastic Elec. Box 3 Circuit Breaker, 20A, 250V * Transformer, 208/ V * Transformer, 240/480, 3KVA * Transformer, 600PRI, 3KVA & 63 - Elec Box 3 Fuse, 30A, 600V Fuseholder, #1, 600V, 30A, 1P A of 20
5 DISCONNECT - 11TH CHARACTER = A, C, E, F, N, P, Q, R, S, X, Y, Z * Patch Plate * Patch Plate * Bracket, Switch Mount DISCONNECT - 11TH CHARACTER = B, D, G, H, J, K, M, T, U, V, W 64 5 Cover, Switch, Plastic Circuit Breaker, 20A, 480V Circuit Breaker, 50A, 240V Circuit Breaker, 60A, 240V Circuit Breaker, 70A, 240V Circuit Breaker, 90A, 240V Circuit Breaker, 100A, 240V Circuit Breaker, 125A 240V Circuit Breaker, 30A, 480V Circuit Breaker, 35A, 480V Circuit Breaker, 40A, 480V Circuit Breaker, 45A, 480V Circuit Breaker, 50A, 2480V Circuit Breaker, 60A, 480V Circuit Breaker, 70A, 240V Circuit Breaker, 25A, 600V Circuit Breaker, 35A, 600V Circuit Breaker, 40A, 600V Circuit Breaker, 45A, 600V Circuit Breaker, 60A, 600V SMOKE DETECTOR, SUPPLY AIR * No Detector Harness, Jumper SMOKE DETECTOR - 11TH CHARACTER = E, G, J, L, M, N, Q, R, U, W, X, Z * Smoke Detector Kit SMOKE DETECTOR, RETURN AIR * No Detector Harness, Jumper SMOKE DETECTOR - 11TH CHARACTER = F, H, K, L, M, P, Q, R, V, W, Y, Z * Smoke Detector Kit PHASE MONITOR 66 - See 3 Phase Monitor Elec Box CABINET PARTS 67 5 Guard, Fan Skirt, Condenser Coil Roof, Condenser Guard, Condenser, Wire, Cond. End of A-0605
6 CABINET PARTS (CONTINUED) 71 5 Wall, Condenser, Service Side Patch Plate, Condenser Wall * Bracket, Rail, Corner Rail, Condenser End Guard, Condenser Wire, SVC Side Rail, Front & Back Hinge Bracket, Double ** Pin, Hinge, Plastic Bracket, Hinge, Single Door, Heat Access Door, Blower Access Wall, Service, Heat Entry Knob, Plastic, Fluted Plate, Latch Bracket, Hinge, Leafed Door, Filter/Control Access Wall, Service, Cooling Entry Rail, Evaporator End Panel, Economizer, Lower Panel, Economizer, Upper Bracket, Hinge, Upper Control Roof, Evaporator Cover, Duct Wall, Duct Panel Guard, Condenser, Wire, Back, Side Wall, Condenser, Duct Side Support, Center, Condenser Roof * Tab, Filter Removal ECONOMIZER * Wire Harness, Jumper DOWNFLOW, W/POWER EXHAUST * Damper, Return Air, Downflow * Damper, Return Air, Downflow * Damper, Return Air, Downflow * Filter * Damper, Fresh Air, Downflow ** * Hood, Fresh Air & Return Air SIDE FLOW * Damper, Fresh Air, Horizontal * Econo., DwnFlw-FA/SideFlw-RA ** * Hood, Horizontal A of 20
7 SIDE FLOW, BAS * Damper, Fresh Air, Hrz., Belimo Act * Econo., DownFlw-FA/SideFlw-RA ** * Hood, Horizontal ECONOMIZER W/BAROMETRIC RELIEF * Damper, Return Air, w/baro. Relief * Filter * Damper, Fresh Air, Downflow ** * Hood, Fresh Air & Return Air ECONOMIZER, SLAB W/BAROMETRIC RELIEF * Damper, Return Air, Slab Econo ** * Hood, Slab Econo ** BAS CONTROLS 97 - See Elec. Box 3 Control, Novar * Sensor, Temperature, Novar * Switch, Pressure, Differential * Relay, SS, Control * Capacitor, 100UF, 50WVDC See Elec. Box 3 Transformer,.075KVA, 460PRI See Elec. Box 3 Circuit Breaker, 3.2A, 250V * Pressure Tap * Bracket, Temperature Sensor STANDARD FILTER - 9TH CHARACTER ALL EXCEPT L, M, Y, OR Z * Filter, Fiber Glass, 2 x 16 x DOWNFLOW UNITS ONLY - 9TH CHARACTER L, M, Y, OR Z * Filter, Pleated, 2 x 16 x of A-0605
8 DS-08 COMPRESSORS 1 1 Compressor, H20J443DBDA Compressor, H20J443DBEA Compressor, H20J443DBFA MOUNTING COMPONENTS 2 1 Screw, Tapping, w/sleeve Grommet, Rubber CONDENSER FAN MOTORS 4 1 Blade, Fan, 24" Dia., 31 Deg Arm, Motor Mount Belly Band, Motor Mount Motor, Fan, 1/3HP, 208/ Motor, Fan, 1/3HP, Motor, Fan, 1/3HP, See Elec. Box 3 Capacitor, Run, 10.0/ MFD, 370V See Elec. Box 3 Capacitor, Run, 10.0/ MFD, 440V * Harness, Wire STANDARD INDOOR BLOWER MOTORS: 9TH CHARACTER = A THRU M 8 2 Motor, Blower, 3.0HP, 200/230/ Motor, Blower, 3.0HP, Sheave, Variable, 1Grv,.875 Bore Sheave, Fixed, 1 Grv, Bore HIGH STATIC INDOOR BLOWER MOTOR: 9TH CHARACTER = N THRU Z 8 2 Motor, Blower, 3.0HP, 200/230/ Motor, Blower, 3.0HP, Sheave, Variable, 1Grv,.875 Bore Sheave, Fixed, 1 Grv, Bore INDOOR BLOWERS: COMMON PARTS 14 2 Blower Rail, Blower Side Belt, V, A Arm, Blower Adjustment, Left, 7.5T Arm, Blower, Adjustment, Right, 7.5T * Key, Stl, 1/4 Sq. x Lg ** * Switch, Limit, 200 Manual A of 20
9 BOX ELECTRIC: COOLING ONLY 16 3 Control, Simplicity, Lockout Circuit Breaker, 3.2A, 250V CB Terminal Block, 3P, 600V, 335A TB * Lug, Electrical GRND Contactor, Elec., 30Amp, 3P M1, Contactor, Elec., 20Amp, 2P M Contactor, Elec., 30Amp, 1P M Transformer,.075KVA T Transformer,.075KVA T Transformer, 575V/24V 75A T * Control, Temp. Switch, SPST LAS * Control, Temp.SPST, 26F FS1, BAS Controller BOX ELECTRIC: GAS HEAT 16 3 Control, Simplicity, Lockout Circuit Breaker, 3.2A, 250V CB Terminal Block, 3P, 600V, 115A TB * Lug, Electrical GRND Contactor, Elec., 30Amp, 3P M1, Contactor, Elec., 20Amp, 2P M Contactor, Elec., 30Amp, 1P M Transformer,.075KVA, 208/230 T1, Transformer,.075KVA, 460PRI T Transformer, 575V, 75A T * Control, Temp. Switch, SPST LAS * Control, Temp., SPST, 26F FS1, Transformer, 460/ T Fuse, Dual, 50A, 600V FU1, BAS Controller BOX ELECTRIC: ELECTRIC HEAT 16 3 Control, Simplicity, Lockout Circuit Breaker, 3.2A, 250V CB Terminal Block, 3P, 600V, 335A TB * Lug, Electrical GRND Contactor, Elec., 30Amp, 3P M1, Contactor, Elec., 20Amp, 2P M Contactor, Elec., 30Amp, 1P M Transformer,.075KVA, 208/230 T Transformer,.075KVA, 460 T Transformer, 575V/24V 75A T * Control, Temp., Switch, SPST, 55/ 45 LAS * Control, Temp. Switch, SPST, 26F FS1, of A-0605
10 EVAPORATOR COIL 27 1 Coil, Evaporator, 3Rx32x ** Distributor, 7Tube, # ** Distributor, 8Tube, # ** * Header, Evap, Sys * Header, Evap, Sys ** Pan, Drain Pan, Drain, SS CONDENSER COIL 31 1 Coil, Condenser, Sys. 2 (Sloped) ** * Header, Cond, DIS, S ** * Header, Cond, RET, S1&S ** Coil, Condenser, Sys. 1(Vertical) ** * Header, Condenser, RET, S ** * Header, Condenser, DIS, S ** PIPING 34 1 Switch, Low Press., 7Open/ 22Close Switch, Pressure, 405 PSIG Filter, Solid * Core, V Port * Cap, Seal * Valve Stem, 1/4 OD Muffler, Discharge HEAT SECTION: NO HEAT / ELECTRIC HEAT * - Harness, Jumper GAS HEAT 37 4 Heat Exchanger, 4Tube, Al * Baffle, Heat Exch. Tube, AL only Heat Exchanger, 4Tube, SS Heat Exchanger, 6Tube, Al * Baffle, Heat Exch. Tube, AL only Heat Exchanger, 6Tube, SS Plate, Balance, 4Tube, Al Plate, Balance, 4Tube, SS Plate, Balance, 6Tube, Al Plate, Balance, 6Tube, SS Control, Ignition Cover, Ignition Control Switch, Limit, Plate, Shoot Through Bracket, Burner Burner Valve, Gas A of 20
11 GAS HEAT (CONTINUED) 46 4 Bracket, Manifold Manifold Igniter Orifice, Gas Sensor, Flame Shield, Air Switch, Limit, 300 Manual Screen, Vent Pipe 98970** Vent Pipe, Al Vent Pipe, SS Blower, Combustion, w/motor Switch, Pressure * Pressure Tap ELECTRIC HEAT * Heater Element, V, 09KW ** * Heater Element, V, 18KW ** * Heater Element, V, 24KW ** * Heater Element, V, 36KW ** * Heater Element, 460V, 09KW ** * Heater Element, 460V, 18KW ** * Heater Element, 460V, 24KW ** * Heater Element, 460V, 36KW ** * Heater Element, 575V, 09Kw ** * Heater Element, 575V, 18Kw ** * Heater Element, 575V, 24Kw ** * Heater Element, 575V, 36Kw ** CONVENIENCE OUTLET - 11TH CHARACTER = A, B, E, F, G, H, L, R * Cover Plate, Outlet NON-POWERED CONVENIENCE OUTLET - 11TH CHARACTER = C, D, J, K, M, N, P, Q 57 5 Outlet, Convenience * Switch, Toggle, 30Amp, 600V Cover, Switchplate POWERED CONVENIENCE OUTLET - 11 CHARACTER = S, T, U, V, W, X, Y, Z 57 5 Outlet, Convenience * Switch, Toggle, 30Amp, 600V Cover, Switch, Plastic Elec. Box 3 Circuit Breaker, 20A, 250V * Transformer, 208/ V * Transformer, 240/480, 3KVA * Transformer, 600PRI, 3KVA & 63 - Elec Box 3 Fuse, 30A, 600V Fuseholder, #1, 600V, 30A, 1P of A-0605
12 DISCONNECT - 11TH CHARACTER = A, C, E, F, N, P, Q, R, S, X, Y, Z * Patch Plate * Patch Plate * Bracket, Switch Mount Cover, Switch, Plastic DISCONNECT - 11TH CHARACTER = B, D, G, H, J, K, M, T, U, V, W 64 5 Cover, Switch, Plastic Circuit Breaker, 50A, 240V Circuit Breaker, 60A, 240V Circuit Breaker, 70A, 240V Circuit Breaker, 80A, 240V Circuit Breaker, 90A, 240V Circuit Breaker, 110A, 240V Circuit Breaker, 25A, 480V Circuit Breaker, 30A, 480V Circuit Breaker, 35A, 480V Circuit Breaker, 40A, 480V Circuit Breaker, 45A, 480V Circuit Breaker, 50A, 480V Circuit Breaker, 60A, 240V Circuit Breaker, 70A, 480V Circuit Breaker, 20A, 600V Circuit Breaker, 25A, 600V Circuit Breaker, 30A, 600V Circuit Breaker, 35A, 600V Circuit Breaker, 40A, 600V Circuit Breaker, 50A, 600V SMOKE DETECTOR, SUPPLY AIR * No Detector Harness, Jumper SMOKE DETECTOR - 11TH CHARACTER = E, G, J, L, M, N, Q, R, U, W, X, Z * Smoke Detector Kit SMOKE DETECTOR, RETURN AIR * No Detector Harness, Jumper SMOKE DETECTOR - 11TH CHARACTER = F, H, K, L, M, P, Q, R, V, W, Y, Z * Smoke Detector Kit PHASE MONITOR 66 - See 3 Phase Monitor Elec. Box A of 20
13 CABINET PARTS 67 5 Guard, Fan Skirt, Condenser Coil Roof, Condenser Guard, Condenser, Wire, Cond. End Wall, Condenser, Service Side Patch Plate, Condenser Wall * Bracket, Rail, Corner Rail, Condenser End Guard, Condenser Wire, SVC Side Rail, Front & Back Hinge Bracket, Double ** Pin, Hinge, Plastic Bracket, Hinge, Single Door, Heat Access Door, Blower Access Wall, Service, Heat Entry Knob, Plastic, Fluted Plate, Latch Bracket, Hinge, Leafed Door, Filter/Control Access Wall, Service, Cooling Entry Rail, Evaporator End Panel, Economizer, Lower Panel, Economizer, Upper Bracket, Hinge, Upper Control Roof, Evaporator Cover, Duct Wall, Duct Panel Guard, Condenser, Wire, Back, Side Wall, Condenser, Duct Side Support, Center, Condenser Roof * Tab, Filter Removal ECONOMIZER * Wire Harness, Jumper DOWNFLOW, W/POWER EXHAUST * Damper, Return Air, Downflow * Damper, Return Air, Downflow * Damper, Return Air, Downflow * Filter * Damper, Fresh Air, Downflow ** * Hood, Fresh Air & Return Air of A-0605
14 SIDE FLOW * Damper, Fresh Air, Horizontal * Econo., DownFlw-FA/SideFlw-RA ** * Hood, Horizontal SIDE FLOW, BAS * Damper, Fresh Air, Hrz., Belimo Act * Econo., DownFlw-FA/SideFlw-RA ** * Hood, Horizontal ECONOMIZER W/BAROMETRIC RELIEF * Damper, Return Air, w/baro. Relief * Filter * Damper, Fresh Air, Downflow ** * Hood, Fresh Air & Return Air ECONOMIZER, SLAB W/BAROMETRIC RELIEF * Damper, Return Air, Slab Econo ** * Hood, Slab Econo ** BAS CONTROLS 97 - See Elec. Box 3 Control, Novar * Sensor, Temperature, Novar * Switch, Pressure, Differential * Relay, SS, Control * Capacitor, 100UF, 50WVDC See Elec. Box 3 Transformer,.075KVA, 460PRI See Elec. Box 3 Circuit Breaker, 3.2A, 250V * Pressure Tap * Bracket, Temperature Sensor STANDARD FILTER - 9TH CHARACTER ALL EXCEPT L, M, Y, OR Z * Filter, Fiber Glass, 2 x 16 x DOWNFLOW UNITS ONLY - 9TH CHARACTER L, M, Y, OR Z * Filter, Pleated, 2 x 16 x A of 20
15 FIGURE 1 FIGURE 2 15 of A-0605
16 FIGURE 3 FIGURE A of 20
17 FIGURE 5 FIGURE 6 17 of A-0605
18 A of 20
19 19 of A-0605
20 Subject to change without notice. Printed in U.S.A. Copyright 2005 by Unitary Products Group. All rights reserved A-0605 Supersedes: Nothing Unitary 5005 Norman Products York OK Group Drive 73069
Replacement Parts List
Replacement Parts List SINGLE PACKAGE AIR CONDITIONER GENERATION 4 42 CABINET Note: This is a non-comprehensive parts list intended for stocking purposes for first production (style A) units based on current
More informationPAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)
www.source1parts.com HVAC SERVICE PARTS PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A) Supersedes:035-21137-001 Rev. E (1107) 035-21137-001 Rev. F (0611) 1 of 8 CONDENSER ROOF (SEE
More informationRP8.1Y (ERRATA 1) (202) 2 of 8
530.18-RP8.1Y (ERRATA 1) (202) 2 of 8 ELECTRICAL (Cont.) FIG ITEM DESCRIPTION D6CG048N06006A D6CG048N06025A D6CG048N06046A D6CG048N06058A 3-BURNER 3-BURNER 3-BURNER 3-BURNER * 15 CONNECTOR, CAP (9-CIRCUIT)
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals
More informationDDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)
www.source1parts.com HVAC SERVICE PARTS DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B) Supersedes:035-23383-001 Rev. A (1211) 035-23383-001 Rev. B (0112) 1 of 14
More informationPT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)
PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20700-001 Rev. B (0805) 035-20700-001 Rev. C (1105) 1 of 8 Figure 1: DOWNFLOW/HORIZONTAL 2-STAGE
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED AC UNIT WITH OPTIONAL ELECTRIC HEAT P7TQ SERIES 6-, 7.5-, AND 10-TON IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper
More informationFC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B) Supersedes: Nothing, See Back 035-21322-001 Rev.
More informationPC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A) Supersedes: 035-214-001 Rev. B (0706) 035-214-001 Rev. C (1006)
More informationGM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20716-001 Rev. A (0205) 035-20716-001 Rev. B (1005) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the
More informationFC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C) Supersedes: 035-21088-001 Rev. B (0806) 035-21088-001 Rev. C (0507) 1 of 8 31
More informationFC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A) Supersedes: 035-20615-001 Rev. C (1004) 035-20615-001 Rev. D (0507) 1 of 8
More informationFL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)
www.source1parts.com HVAC SERVICE PARTS FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A) Supersedes: 035-21211-001 Rev. C (1106) 035-21211-001 Rev. D (0708) 1 of 8 33 31 5 10 41
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. A (0313) 035-23623-001 Rev. B (0613) 26 1 of 6 44
More informationGM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)
www.source1parts.com HVAC SERVICE PARTS GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B) Supersedes: 035-21326-001 Rev. A (0207) 035-21326-001
More informationGM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)
www.source1parts.com HVAC SERVICE PARTS GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J) Supersedes: 035-21080-001 Rev. D (0207) 035-21080-001 Rev. E (0507) 1 of 12 31 29 26 5 10 39 69 24 11
More information48TF GAS HEATING/ ELECTRIC COOLING UNITS
48TF-4SB 48TF004-014 GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationGF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)
www.source1parts.com HVAC SERVICE PARTS 32 GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G) Supersedes: 035-20372-001 Rev. D (0205) 035-20372-001 Rev. E (0507) 74 1 of 12 Figure 1: UPFLOW CONDENSING
More informationGM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)
GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K) www.source1parts.com HVAC SERVICE PARTS Supersedes: Nothing 035-21295-001 Rev. A (1206) 1 of 12 31 29 26 5 10 39 69 24 11 12 16 58 61 40 13
More informationDCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER
More informationPS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90% www.source1parts.com HVAC SERVICE PARTS Supersedes: 035-21082-001 Rev. A (1205) 035-21082-001 Rev. B (1106) 1 of 12 31 29 5 61 26 10 39 69 12 11 16
More informationTG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS
www.source1parts.com HVAC SERVICE PARTS 41 TG8S SERIES 80% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE A) INCLUDES LO-NOX MODELS TGLS Supersedes: 035-21389-001 Rev. K (0410) 035-21389-001
More information48TM GAS HEATING/ELECTRIC COOLING UNITS
48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationTG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B)
www.source1parts.com HVAC SERVICE PARTS 23 TG9S SERIES 95% SINGLE STAGE MULTI-POSITION 33 NATURAL GAS FURNACES (STYLE B) Supersedes: 035-23623-001 Rev. H (1115) 035-23623-001 Rev. J (1117) 26 1 of 6 44
More informationPS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20712-001 Rev. B (1005) 035-20712-001 Rev. C (1105) 1 of 12 Figure 1: UPFLOW NATURAL GAS FURNACES (90%) FIG ITEM
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGE AIR CONDITIONER Models: W7A W8A WA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of
More informationPT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES
www.source1parts.com HVAC SERVICE PARTS PT8 SERIES 2-STAGE UPFLOW/HORIZONTAL 80% NATURAL GAS FURNACES (STYLE D, Some B) INCLUDING LO-NOX MODELS Supersedes: Nothing 035-21348-001 Rev. A (0307) 1 of 8 8
More informationPS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%
PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90% HVAC SERVICE PARTS Supersedes: 035-20437-001 Rev. C (1004) 035-20437-001 Rev. D (1204) 1 of 8 Figure 1: UPFLOW 1-STAGE NATURAL GAS FURNACES (90%) FIG
More informationMcQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016
Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet
More informationWeathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT
More informationGM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)
GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A) HVAC SERVICE PARTS Supersedes: 035-20642-001 Rev. A (0904) 035-20642-001 Rev. B (0205) 1 of 8 Figure 1: UPFLOW 2-STAGE VARIABLE
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
More informationPT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%
PT9 SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90% HVAC SERVICE PARTS Supersedes: 035-20714-001 Rev. C (1005) 035-20714-001 Rev. D (1105) 1 of 8 Figure 1: UPFLOW 2-STAGE NATURAL GAS FURNACES
More informationFC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%)
FC8T SERIES 2-STAGE UPFLOW/HORIZONTAL NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (MODEL LC8) (STYLE B) HVAC SERVICE PARTS Supersedes: 035-20671-001 Rev. C (0605) 035-20671-001 Rev. D (1105) 1 of 8 Figure
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationPT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)
www.source1parts.com HVAC SERVICE PARTS PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A) Supersedes: 035-20487-001 Rev. C (1004) 035-20487-001 Rev. D (1014) 1 of 8 31 65 24 5 8 53 63 35
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationREPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models
REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models IMPORTANT This document is primarily intended to assist qualified individuals experienced in the proper repair
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGED AIR CONDITIONER W0AA-A W0AA-B W0AA-C W0AA-D W0AA-F WAA-A WAA-B WAA-C WAA-D WAA-E WAA-F Models: W0AADA W0AADB W0AADC WAADA WAADB WAADC Contents Description
More informationCATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO
CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN HSROG ML-111148 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43003 (June 2001) HOT SECTION 26 OVEN TOP SECTION
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationAD-115ES Parts Manual
AD-115ES Parts Manual 24 VAC Phase 7 / S.A.F.E. System July 2002 American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationReplacement Parts List For Models COS-20G
Replacement Parts List For Models COS-20G (Ovens with s/n HP & HT) Contents: Page # Electrical Compartment:Contactors,Steam Generator,Thermostats 2-5 Oven Interior: 5 Bottom Section: Gas, Plumbing Components
More informationSlow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.)
Tumbler turns ignition sparks no flame Gas supplymake sure gas supplyis working Gas pressure Make manometer check of gas pressure for 3.5" W.C. or more at supply side Spark electrode Gas valve Check electrode
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED VARIABLE CAPACITY ENVIRONMENTAL CONTROL UNIT WRV-S WRV-T Models: WLV-S WLV-T Contents Description Page Cabinet Components Right (Extreme Duty Door) Exploded View...
More informationDCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h
Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling
More informationDSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER
DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard
More informationGas-Fired Indoor and Outdoor Duct Furnaces
July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationDCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER
DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:
More informationDCG Commercial. Submittal Data Form
DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationShelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016
Shelleybasic Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 0 Contents Condensing Unit Assembly, / HP, Ra... Condensing Unit Assembly, / HP, R0a... Condensing
More informationEXPLODED VIEWS & PARTS LISTS
542 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 536306-UAI-B-1009 Electric Heat Accessory 10, 16, 20, 26, 32, 36 & 52kW For Split-System R-410A Air Handling Units Both Air Conditioners and Heat Pumps 7-1/2, 10,
More informationSCE170 SERVICE PARTS
This is the parts list for the SCE170. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The SCE170 has been manufactured in
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More information(EE1500, EE2000, EE2500, EE3000)
EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000
More informationUNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8
SERVICE UNIT INFORMATION Corp. 9121 L7 CHA16 2 5 TON UNITS Litho U.S.A. CHA16 series units in the 2 5 ton sizes were introduced in the spring of 1990. The single package cooling units may be used in both
More informationACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS
ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS For 13 SEER SJ, PAC R-22 Packaged Air Conditioners JP, PHP R-22 Packaged Heat Pumps NM, NL R-410A Packaged
More informationDCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners
DCG Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant
More informationGENERAL. Model 2SD UAI-A Before installing read all of the manufacturers installation and maintenance instructions.
ACCESSORY KIT INSTALLATION INSTRUCTION SMOKE DETECTOR KITS, UNIT MOUNT MODELS 2SD04700824, 2SD04700924 AND 2SD04701024 For 3.0 THRU 12.5 TON ROOFTOP UNITS GENERAL Before installing read all of the manufacturers
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More information2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)
2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%) INCLUDING LO-NOX (See Page 6) HVAC SERVICE PARTS Supersedes: 035-17432-000 Rev. B (1201) 035-17432-000 Rev. C (0304) 1 of 8 Figure
More information48PGD/E/F/L/M/N PG20-28
48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More informationP8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units
TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationCME1056 Service Parts. Table of Contents
This is the parts list for the CME0 ice machine. The CME0 was manufactured in A, D, E and F series, as well as single phase 0 Hz, single phase 0 Hz, and three phase. The E series change was to side panels
More informationRANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.
BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED
More informationBCX-14 & BX-14 COMBINATION OVEN STEAMER CNVX-14 CONVECTION OVEN REPLACEMENT PARTS LIST
BCX- & BX- COMBINATION OVEN STEAMER CNVX- CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event
More informationINSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BP
INSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BP 036-072 CONTENTS GENERAL................................ 4 SAFETY CONSIDERATIONS................. 4 INSPECTION..............................
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More information50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT
50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationAD-360X2 Parts Manual
AD-360X2 Parts Manual Phase 7 American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447 e-mail: techsupport@amdry.com www.adclaundry.com
More informationTECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES
036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING
More informationMcQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998
Replacement Parts List No. 04765700 Revision E 04/08 McQuay Roofpak Roof Mounted Air Handler Draw- Through RDS Size: 900 Vintage: B Last Manufactured: 998 To find your Daikin Applied parts distributor,
More informationINSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)
INSTALLATION MANUAL CONTENTS GENERAL...................................... 3 INSPECTION.................................... 3 INSTALLATION.................................. 3 REFERENCE....................................
More informationRoof Top Packaged Unit (RTU-1) Specification
Roof Top Packaged Unit (RTU-1) Specification Item Tag(s) Qty Description Model Number A2 10 Ton 1 10 Ton R410A PKGD Unitary Gas/Electric TRANE: YHC120F3RLA--07C1 Product Data - 10 Ton R410A PKGD Unitary
More informationFEATURES AND BENEFITS
FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED SASO CERTIFIED AIR CONDITIONER Models: KA-N KA-N K0A-N General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan
DTC Series 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER Cooling Capacity: 35,600 60,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation
More informationThis parts list is current as of the above revision date. See for the current revision.
URM- Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-urm-.pdf for the current revision. Package Gas-Electric Table of Contents Model Explanation...................................................................................................................
More informationZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG
More informationMARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)
EXTERIOR SHEET METAL (OUTER PANELS) 1 COMPAC AVP72/AVPA72 PARTS LIST, 03/09 EXTERIOR SHEET METAL (OUTER PANELS) AVP72AC AVPA72AC 1 Panel, Back (Galvanized) M/04443SP 2 Right Side Panel, ComPac II M/04465XXSP
More informationSUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES
50.TGY (95) SINGLE PACKAGE COOLED CONDITIONERS DCE 0, 0, 00 & DCE 07 0, 0, 00 & 07, AND 5 NOMINAL TONS (0 SEER) AND NOMINAL TONS (9 EER) SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible
More informationSubmittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat
SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL W0HA-A W0HA-B W0HA-C WALL MUNTED PACKAGED HEAT PUMP WHA-A WHA-B WHA-C Models: W0HADA W0HADB W0HADC WHADA WHADB WHADC Contents Description Page Cabinet Components Exploded View...
More information