Product Information and Technical Guide

Size: px
Start display at page:

Download "Product Information and Technical Guide"

Transcription

1 Product Information and Technical Guide 2005 Room ir Conditioners Model Year Designation P Example FS5P1 ThruTheWallExample FH085P1T Slider CasementExmaple FK104P1V Safety update 3 Safe Servicing Practices 4 Model Specifications 511 Compressor Overloads 12 Factory location:rk Restrictor Tube Data 12 Receptacle Codes 13 Product Dimensions 14 Thermostat Diagrams TTENTION SERVICERS! To get a helping hand, visit the Frigidaire Web Site at: User name: service Password: tips Fan/Blower Diagrams 16 Wiring Diagrams 1722 Troubleshooting 2324 Part No.: May 2005

2 TBLE OF CONTENTS Safety Update...3 Safe Servicing Practices...4 Model Specifications Compressor Overload Data...12 Restrictor Tube Data...12 Receptacle Outlet Codes...13 Product Dimensions Control Thermostat s Thermostat Locations ThruTheWall Thermostat Locations Slider Thermostat Locations... Fan and Blower s Slider Casement...16 ThruTheWall...16 Wiring Diagrams Troubleshooting

3 IMPORTNT SFETY UPDTE Room ir Conditioners manufactured after ugust 1st, 2004 are equipped with a new industry regulated power cord with either of the following in the plughead or in line: LCDI: Leakage Current Detection Interrupter FCI: rcfault Circuit Interrupter. ll Frigidaire products have an LCDI located in the plug head or inline. The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord does the following: 1. Plug in the ir Conditioner. 2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will notice a click as the RESET button pops out. 3. Press the RESET button. gain you will notice a click as the button engages. 4. The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head). Notes: Do not use this device to turn the unit on or off. lways make sure the RESET button is pushed in for correct operation. The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. new one can be obtained from the product manufacturer. If power supply cord is damaged, it CNNOT be repaired, it MUST be replaced by one obtained from the product manufacturer. 3

4 SFE SERVICING PRCTICES LL PPLINCES To avoid personal injury or property damage, it is important that Safe Servicing Practices be observed. The following are some limited examples of safe practices. 1. DO NOT attempt a product repair if you doubt your ability to complete it in a safe and satisfactory manner. 2. Before servicing or moving an appliance Remove power cord from electrical outlet, trip circuit breaker to OFF position, or remove fuse Turn off gas supply Turn off water supply 3. Never interfere with the proper operation of any safety device. 4. Use only OEM replacement parts cataloged for this appliance. Substitutions may defeat compliance with safety standards set for home appliances. 5. GROUNDING: The standard color coding for safety ground wires is GREEN, or GREEN with YELLOW STRIPES. DO NOT use ground leads as current carrying conductors. It is EXTREMELY important that the service technician reestablish all safety grounds prior to completing service. Failure to do so will create an electrical hazard. 6. Prior to returning the product to service, ensure that ll electrical connections are correct and secure ll electrical leads are properly dressed and secured away from sharp edges, hightemperature components, and moving parts ll noninsulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal parts and panels ll safety grounds (both internal and external) are correctly and securely connected ll panels are properly and securely reassembled. 7. In the event that the power cord is damaged, it cannot be repaired. It must be replaced with a new one from the product manufacturer. WRNING This service manual is intended for use by persons having electrical and mechanical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. Electrolux Home Products Inc. Cannot be responsible, nor assume any liability, for injury or damage of any kind arising from the use of this manual Electrolux Home Products, Inc. 4

5 FRIGIDIRE MODEL SPECIFICTIONS Model FS5P11 FS5P12 FS6P11 FS6P12 FS7P11 Chassis Type BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only NEM 5 KT21C712(U) Page 17 10/ / NEM 5 KT21C712(U) Page 17 10/ / NEM 5 KT21C712(U) Page 17 10/ / NEM 5 KT21C712(U) Page 17 10/ / NEM 5 KT21C712(U) Page 17 10/ /450 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type Sanyo MR F/250V MR u/250V Sanyo MR F/250V MR u/250V Sanyo MR F/250V Installation Instructions Kit Type Part Number Control Thermostat Page Page Page Page Page Condenser Fan and Evaporator Blower 5

6 FRIGIDIRE MODEL SPECIFICTIONS Model FS7P12 FS182P21 FS184P21 FS185P21 FS186P21 Chassis Type BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only NEM 5 KT21C712(U) Page 17 10/ / / / /1830 NEM 6 KT21C713(U) Page 18 6 F/450V / / / / /1830 NEM 6 KT21C713(U) Page 18 6 F/450V / / / / /1700 NEM 6 KT21C713(U) Page 19 6 F/450V / / / /1700 NEM 6 KT21C713(U) Page 19 6 F/450V /470 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type MR u/250V Samsung MR F/450V Mechanical Samsung MR F/450V Samsung MR F/450V Samsung MR F/450V Installation Instructions Kit Type Part Number Control Thermostat Page Page Page Page Page Condenser Fan and Evaporator Blower 6

7 FRIGIDIRE MODEL SPECIFICTIONS Model FS187P21 FS18EP21 FS225P21 FS226P21 Chassis Type BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # 18500/ / /1700 NEM 6 KT21C713(U) Page / / / / / / NEM 630 KT21C804(U) Page / / /2300 NEM 6 KT21C803(U) Page / / /2300 NEM 6 KT21C803(U) Page 19 ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only 6 F/450V /470 6 F/450V /470 6 F/450V /480 6 F/450V /480 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type Samsung MR F/450V Samsung MR F/450V HM F/450V HM F/450V Installation Instructions Kit Type Part Number Control Thermostat Page Page Page Page Condenser Fan and Evaporator Blower 7

8 FRIGIDIRE MODEL SPECIFICTIONS Model FS255P21 FS256P21 FS25EP21 FS294P21 FS296P21 Chassis Type BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # 25000/ / / NEM 620 KT21C803(U) Page / / / NEM 620 KT21C803(U) Page / / / / / / NEM 630 KT21C804(U) Page / / / NEM 630 KT21C804(U) Page / / / NEM 630 KT21C804(U) Page 20 ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only 6 F/450V /480 6 F/450V /480 6 F/450V / F/450V / F/450V /500 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type Samsung HM uF/400V /10 Samsung HM uF/400V /10 Samsung HM uF/400V /10 * * * Samsung HM uF/400V Samsung HM uF/400V 48.7 # # Installation Instructions Kit Type Part Number Control Thermostat Page Page Page Page Page Condenser Fan and Evaporator Blower * Restrictor tube part numbers: & # Restrictor tube part numbers: , , &

9 FRIGIDIRE MODEL SPECIFICTIONS Model FK085P7V1 FK104P1V1 FK107P1V1 FK124P1V1 FK127P1V1 Chassis Type BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only Slider Casement NEM 5 KT21C627(U) Page 20 8 F/250V / / /160 Slider Casement NEM 5 KT21C627(U) Page 20 8 F/250V / / /205 Slider Casement NEM 5 KT21C627(U) Page 20 8 F/250V / / /205 Slider Casement NEM 5 KT21C712(U) Page 20 8 F/250V / / /205 Slider Casement NEM 5 KT21C712(U) Page 20 8 F/250V / / /205 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type Panasonic MR98503or uF/250V / MR F/250V MR F/250V MR F/250V / / MR F/250V / / Installation Instructions Kit Type Part Number V V V V V Control Thermostat Page Page Page Page Page Condenser Fan and Evaporator Blower 9

10 FRIGIDIRE MODEL SPECIFICTIONS Model FH085P1T1 FH08EP1T1 FH105P1T1 FH105P2T1 Chassis Type Thruthewall Thruthewall Thruthewall Thruthewall BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # NEM 5 KT21C7(U) Page NEM 5 KT21C7(U) Page NEM 5 KT21C7(U) Page / / /1040 NEM 6 KT21C714(U) Page 21 ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only 12uF/450V / / /205 12uF/450V / / /205 12uF/450V / / / uF/450V / / /185 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type Hili MR F/250V Hili MR F/250V MR F/250V MR F/450V Installation Instructions Kit Type Part Number T T T T Control Thermostat Page Page Page Page Condenser Fan and Evaporator Blower 10

11 FRIGIDIRE MODEL SPECIFICTIONS Model FH10EP2T1 FH125P2T1 FH12EP2T1 Chassis Type Thruthewall Thruthewall Thruthewall BTU Cooling BTU Heating Moisture Removal EER Voltage mps Cooling mps Heating Watts Cooling Watts Heating Fuse/Breaker(mps) Receptacle Code Power Cord Number Power Cord mps Min Wiring Diagram Page # ir Flow System Capacitor Farads Fan Motor Mfg. Fan Motor Number RPM/CMP(EVP) High Medium Low Heat Only 10000/ / / / / /2500 NEM 6 KT21C714(U) Page uF/450V / / / / / /1250 NEM 6 KT21C714(U) Page uF/450V / / / / / / / / /2600 NEM 6 KT21C714(U) Page uF/450V / / /195 Refrigeration System Compressor Mfg. Compressor Number Compressor Type Overload Protector Capacitor Farads Refrigerant Charge Restrictor Tube Thermostat Type MR F/450V MR F/450V MR F/450V Installation Instructions Kit Type Part Number T T T Control Thermostat Page Page Page Condenser Fan and Evaporator Blower 11

12 Supplier Part# MR MR MR HM408 3HM HM53541 MR98503or MR MR MR MR MR Used With Compressor QXE19(F) QK208C 48D172IUEL QP306KBB 55260IU2JM 55300IU1JM 2R12S3R126UB QK141CCD QK164CBF SD104SWP3U QK141KBH QK164KBK Compressor Overload Data Opening Temp Closing Temp Short Time Tripat 25 Test mp Opeing TimeSec ~ *Terminal to overload must withstand 10 pounds pull test. Restrictor Tube Data Style# Length O.D. I.D. Mpa CFM Dry ir Minimum Maximum

13 Receptacle Outlet Codes 1 Voltsmps NEM 5 TYPE Power Supply Cord with 3prong Grounding Plug 230 Voltsmps NEM 6 TYPE 230 Volts20mps NEM 620 TYPE DO NOT under any circmstances cut or remove the grounding prong from this plug. Grounding Type Wall Receptacle 230 Volts30mps NEM 630 TYPE 13

14 Product Dimensions Slide Out Top Control Top ir Discharge 26 1/2 Slider Casement 14 1/2 18 1/2 20 1/2 25 1/2 Maximum Wall Thickness 9 23 Thru The Wall No Side Louvers /2 20 Maximum Wall Thickness 22 14

15 Thermostat Diagrams Electric Model 20 5th Row From Top 6th Row From Top Sensing Cap Must Not Touch Fins Evap. Fin ir thermistor and thermistor holder Side View Model 20 5th Row From Top 6th Row From Top Sensing Cap Must Not Touch Fins Evap. Fin ir thermostat and thermostat holder Side View Thru The Wall ir thermistor and thermistor holder (Place between 3th and 4th rows tubes up from the top.) 2 3th Row From Top 4th Row From Top Side View Sensing Cap Must Not Touch Fins Evap. Fin Center line of the evaporator 3th Row From Top 4th Row From Top Sensing Cap Must Not Touch Fins Evap. Fin Side View ir thermistor and thermistor holder (Place between 3th and 4th rows tubes up from the top.)

16 Fan and Blower s Top Control Evaporator Side Top Fan Shell Clockwise Nut Left Bulkhead Condenser Side Counterclockwise Nut Blower Wheel To be fully seated against motor shaft. (bottom out on shaft) Motor Shaft Condenser Fan To be fully seated against motor shaft. (bottom out on shaft) Blower Wheel (Centrifugal Fan) Motor Motor Bracket Oriented Board Fan Blade (xial Fan) Clockwise Nut Evaporator Side Counterclockwise Nut Condenser Side Slider Casement Evaporator Side Condenser Side Fan Shell Bulkhead Blower Wheel To be fully seated against motor shaft. (bottom out on shaft) Motor Shaft Condenser Fan To be fully seated against motor shaft. (bottom out on shaft) Motor Fan Blade (xial Fan) Counterclockwise Nut Evaporator Side Clockwise Nut Condenser Side Blower Wheel (Centrifugal Fan) Motor Bracket 5/16 5/16 5/16 Base Thru The Wall Evaporator Side Condenser Side Top Fan Shell Clockwise Nut Connection Bar Motor Counterclockwise Nut Blower Wheel To be fully seated against motor shaft. (bottom out on shaft) Motor Shaft Condenser Fan To be fully seated against motor shaft. (bottom out on shaft) Motor Bracket Blower Wheel Left Bulkhead (Centrifugal Fan) Oriented Board Fan Blade (xial Fan) Counterclockwise Nut Evaporator Side Clockwise Nut Condenser Side 16

17 Wiring Diagrams

18 Wiring Diagrams

19 Wiring Diagrams

20 Wiring Diagrams

21 Wiring Diagrams

22 Wiring Diagrams

23 ROOM IR CONDITIONERS TROUBLESHOOTING CUTION: Review Safe Servicing Practices in the front of this manual before attempting diagnostic procedures and repairs. Low voltage can also be the direct result of inadequately wired circuits, extension cords, or loose fuses and connections to the power supply. Voltage may also be a general condition in the area (a responsibility of the power company). IR CONDITIONER VOLTGE LIMITS NMEPLTE RTING MINIMUM MXIMUM 1VC 103.5VC 126.5VC 230VC 207VC 253VC 208/230VC 197.5VC 253VC ll units will start and run on the minimum voltage stated in the chart to the left, and will perform satisfactorily if the voltage remains constant. Low voltage caused by defective wiring will not remain constant under load. To test for low voltage, use a reliable meter with sufficient capacity to measure the required voltage. Take measurements at the electric power entry point and at the electric outlet serving the air conditioner. Take readings with the unit off, while the unit is starting, and again while the unit is running. The lowest reading should not drop below the lowest value listed in the chart. IR CONDITIONER VOLTGE LIMITS Low voltage is a common cause of trouble in the operation of any room air conditioner. Improper voltage may cause one or more of the following problems: 1. Unit will not start. 2. Compressor motor cycling on motor protector. 3. Premature failure of motor protector. 4. Blown fuses. 5. Premature failure of compressor or fan motor. 6. Noticeable dimming of lights when air conditioner is running. 7. Evaporator icing. Low voltage may reduce fan speed resulting in inadequate air flow over evaporator, thereby allowing it to ice up. HIGH VOLTGE High voltage can be equally troublesome, causing motors to overheat, cycle on their protectors, or break down electrically. This problem can only be solved by the power company. ELECTRONIC CONTROL This control is not repairable. If any component in the control is defective, the entire control must be replaced. IMPORTNT NOTICE: Repair or replace any malfunctioning line voltage component before testing or replacing the electronic control. DO NOT assume a service problem is directly caused by the electronic control system. line voltage component (including power cord and wiring) that has opened, shorted, grounded or otherwise malfunctioned, may have created a service problem. SYMPTON Fan motor will not run. Fan motor runs intermittently. POSSIBLE CUSE 1. No power. 2. Power supply cord. 3. Selector switch. 4. Energy sawing switch(if applicable). 5. control(if applicable). 6. Wire disconnected or connection loose. 7. Capacitor.(Dischage capacitor before testing.) 8. Defective fan motor windings. 9. Will not rotate. Fan blade hitting shroud or blower wheel hitting scroll. (Motor cycles on overload.) 1. Cycle on motor protector. Fan motor noisy. 1. Condenser fan blade or evaporator blower wheel. 2. Loose power clamp or set screw. 3. Worn bearings. 4. Grommets(if applicable). 23

24 SYMPTON Compressor will not run, but fan motor runs. Compressor cycles on motor protector. Insufficient cooling. POSSIBLE CUSE 1. Voltage. 2. Wiring. 3. Selector switch. 4. Temperature control. 5. Capacitor. (Discharge capacitor before testing.) 6. Compressor. 7. Motor protector(external). 8. Motor protector(internal). 9. control(if applicable). 10. Hard starting. 1. Voltage. 2. Motor protector(external). 3. Motor protector(internal). 4. Fan motor. 5. Condenser air flow restriction. 6. Condenser fins damaged. 7. Capacitor. 8. Wiring. 9. Refrigerant system. 1. Low capacity. 2. ir filter. 3. Exhaust door open. 4. Unit undersized. Excessive noise. Excessive water or condensation. No cooling. 1. Evaporator blower wheel. 2. Condenser wheel. 3. Copper tubing. 4. Compressor internal noise. 5. Fan motor. 1. Unit operating under extremely high humidity conditions. 1. Refrigerant leak. Unit is cooling but room is not cool. Wattage decreases slowly until abnormally low. Wattage decreases immediately. Wattage continues high. Evaporator coil partially frosted. Evaporator completely iced. No heat. Fan motor will not rotate during heat cycle. (Heat/Cool models only.) 1. mps and watts. 2. Sealed refrigeration system. 1. Undercharged, restricted strainer or plugged restrictor tube. 1. No refrigerant 2. Compressor defective. 1. Refrigerant overcharge. 1. System low on refrigerant. 1. Low outside temperature. 1. No power. 2. Selector switch position. 3. Temperature control position. 4. Fan motor. 5. Heating element. 6. Selector switch. 7. Temperature control. 8. Terminals and connectors. 1. Thermostatic drain valve.(what level control, if applicable.) 24

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide 2004 Room Air Conditioners MS2 and Compact 2 Models Safe Servicing Practices 3 Model Specifications 4-11 Compressor Overloads 12 Restrictor Tube Data 12 Receptacle

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Cool Dry Mode Temp Room Air Conditioner Service and Parts Manual 0F Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power CP10 CP12 CP10 - CP12 (06/14) 93011402_04 CONTENTS 1. PREFACE 1.1 SAFETY

More information

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02

Room Air Conditioner CP06 & CP08. Chill 115 Volts. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING _02 Room Air Conditioner Service & Parts Manual 2014-2015 CP06 & CP08 Chill 115 Volts THE EXPERTS IN ROOM AIR CONDITIONING 93011401_02 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE

More information

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control SERVICE DATA SHEET 318047418 (0504) Rev. A Electric Wall Oven with Electronic Oven Control NOTICE This service data sheet is intended for use by persons having electrical and mechanical training and a

More information

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide Side by Side and Top Mount Refrigerators July 2003 - December 2003 White-Westinghouse 5995540384 January 2004 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------

More information

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING

Room Air Conditioner EP08 & EP12. Chill 115 Volts-EP Volts-EP12. Service & Parts Manual THE EXPERTS IN ROOM AIR CONDITIONING Room Air Conditioner Service & Parts Manual 2014-2015 EP08 & EP12 Chill 115 Volts-EP08 230 Volts-EP12 THE EXPERTS IN ROOM AIR CONDITIONING 93011407_00 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2

More information

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide Side by Side and Top Mount Refrigerators January 2005 - June 2005 White-Westinghouse 5995449906 October 2005 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------

More information

Thru-the-Wall Series

Thru-the-Wall Series Uni- Fit R Thru-the-Wall Series Service and Parts Manual Thru-the-Wall Series 115 Volts US08C10 US10C10 US12C10 230 Volts US10C30 US12C30 US14C30 Unifit Cool Svc Parts 2010 (05/10) Unifit. Cool (03/07)

More information

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3.   CAUTION www.zenithappliances.com Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3 CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL. CONTENTS

More information

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide Side by Side and Top Mount Refrigerators January 2004 - March 2004 White-Westinghouse 5995413308 July 2004 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------

More information

Product Information and Technical Guide

Product Information and Technical Guide Product Information and Technical Guide Side by Side and Top Mount Refrigerators April 2004 - December 2004 White-Westinghouse 5995427241 January 2005 TABLE OF CONTENTS Safe Servicing Practices ------------------------------------------------------------------------------------------

More information

SERVICE DATA SHEET (9704) Rev. D

SERVICE DATA SHEET (9704) Rev. D SERVICE DATA SHEET 318047401 (9704) Rev. D Electric Wall Ovens with Electronic Oven Control (ERC III - 318010700 & 318010900) NOTICE This service data sheet is intended for use by persons having electrical

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Room Air Conditioner Service and Parts Manual CP05A10 CP06A10 CP05 / CP06 (06/05) CONTENTS 1. PREFACE...3 1.1 FEATURES...3 1.2 SPECIFICATIONS...3 1.3 LOCATIONS OF CONTROLS...4 1.4 SAFETY PRECAUTIONS...4

More information

SLIDER CASEMENT AIR CONDITIONER

SLIDER CASEMENT AIR CONDITIONER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS SLIDER CASEMENT AIR CONDITIONER ROTARY CONTROL P/N 309000854 (11/03) ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance

More information

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS PREFACE This service manual is primarily intended for the use of qualified individuals specially trained and experienced in the service of this type of equipment

More information

Room Air Conditioner

Room Air Conditioner All about the S e r v i c e of Room Air Conditioner Section 1 Basic Information Section 2 Installation (See the website) Section 3 Operation Instructions Section 4 Trouble Shooting TABLE OF CONTENTS Section

More information

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................

More information

10,000 BTU PORTABLE ROOM AIR CONDITIONER

10,000 BTU PORTABLE ROOM AIR CONDITIONER CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS R-100 10,000 BTU PORTABLE ROOM AIR CONDITIONER Model ACP102PR JOB AID Part No. 8178485 FORWARD This Whirlpool Job Aid, 10,000 BTU Portable Room Air

More information

ROTARY CONTROL AIR CONDITIONER

ROTARY CONTROL AIR CONDITIONER USE & CARE MANUAL NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com UNPACKING

More information

Window Y9USC/E 09 / 12 / 18 B5R

Window Y9USC/E 09 / 12 / 18 B5R Window Y9USC/E 09 / 12 / 18 B5R SERVICE MANUAL Y9USC-09 B5R; Y9USE-09 B5R Y9USC-12 B5R; Y9USE-12 B5R Y9USC-18 B5R; Y9USE-18 B5R SM-Y9USC-E-09-18GB 03-07 1. Precaution... 2 1.1 safety Precaution... 2 1.2

More information

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

AIR CONDITIONER ELECTRONIC CONTROL

AIR CONDITIONER ELECTRONIC CONTROL READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ELECTRONIC CONTROL ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance is warranted by Electrolux. Electrolux has authorized

More information

Service Manual Electric Cooktop

Service Manual Electric Cooktop Service Manual Electric Cooktop 318 202 105 (0311) THIS IS A BLANK PAGE Table of Contents I SAFE SERVICING PRACTICES... 1 PRODUCT FEATURES... 2 WIRING DIAGRAM... 3 SECTION A - INSTALLATION... 4 CUT-OUT

More information

Owner s Manual Window Air Conditioner

Owner s Manual Window Air Conditioner Owner s Manual Window Air Conditioner G17-5MCVWAC1 G16-5MCVWAC Write the model and serial numbers below for your records: Model # Serial # Date Purchased Please read the entire manual carefully to ensure

More information

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

Operating & Maintenance Manual for Islandaire EZ Series WM/LM Water Source Heat Pump Packaged Terminal Air Conditioners.

Operating & Maintenance Manual for Islandaire EZ Series WM/LM Water Source Heat Pump Packaged Terminal Air Conditioners. Operating & Maintenance Manual for Islandaire EZ Series WM/LM Water Source Heat Pump Packaged Terminal Air Conditioners. *THIS BOOK CONTAINS INFORMATION ON THE OPERATION OF YOUR UNIT. KEEP IN A SAFE PLACE

More information

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS TABLE OF CONTENTS 1. Warnings.................................................................. 2 2. Unit Dimensions And Specifications............................................

More information

Thru-the-Wall Series

Thru-the-Wall Series Thru-the-Wall Series Service and Parts Manual Thru-the-Wall Series 115 Volts UE08 230 Volts UE10 UE12 UE08/UE10/UE12 (05/05) CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2 INSULATION RESISTANCE TEST...2

More information

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E

SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT. DocID: 00G00019E SERVICE MANUAL CLASSIC PLUS 14 SERIAL NUMBER FROM JANUARY 2008 (0108) TO PRESENT DocID: 00G00019E 2008 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS TABLE OF CONTENTS 1. Warnings & Component Match-Up............................................ 2 2. Unit Specifications..........................................................

More information

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill of lading to insure all

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513 TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before

More information

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com

More information

REPAIR PARTS LIST For Parts or Service: Call MY-HOME ( ) Or Visit

REPAIR PARTS LIST For Parts or Service: Call MY-HOME ( ) Or Visit REPAIR PARTS LIST 253.76062410 253.76062411 When requesting service or ordering parts, always provide the following Lowpro cover.eps 25376062410 Spares.wmf 202021191106-WD.eps information: For Parts or

More information

Service. Compact Quiet Zone Room Air Conditioners

Service. Compact Quiet Zone Room Air Conditioners Base manual covers general information on Compact Quiet Zone Room Air Conditioners. Refer to individual technical sheets for information on specific models. Service Compact Quiet Zone Room Air Conditioners

More information

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA

SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT DocID: 00G00010EA 2008 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start Mokon Troubleshooting Guide Model 311 Process pump will not start Process pump shuts down during operation Pump seal leak Tank overflows or will not fill on systems with autofill option (water makeup valve)

More information

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11 SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual No.: 2100-479 Supersedes: NEW File: Volume

More information

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features. Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause

More information

SERVICE MANUAL OFFICE PRO 18 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00014EB

SERVICE MANUAL OFFICE PRO 18 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00014EB SERVICE MANUAL OFFICE PRO 18 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT DocID: 00G00014EB 2011 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB Service Manual Models WAH48115MB WAH412230MB WH48YMB WH412ZMB TABLE OF CONTENT SPECIFICATION... 2 OUTLINE AND INSTALLATION DIMENSION... 4 REFRIGERATION SYSTEM DIAGRAM... 5 WIRING SCHEMATIC... 6 CONTROLS

More information

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5 Introduction The Scotsman Compact Refrigerator is a unique product, capable of being built into a cabinet because of its front vented, forced-air cooling system. It s also designed to be a companion to

More information

SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT. DocID: 00G00025E

SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT. DocID: 00G00025E SERVICE MANUAL CLASSIC PLUS 26 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT DocID: 00G00025E 2009 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER USE & CARE MANUAL THIS PORTABLE AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST-RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS PORTABLE AIR CONDITIONER ELECTRONIC

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 2-Stage R-410A Split System These units have been designed and tested for capacity & efficiency in accordance with A.H.R.I. Standards.

More information

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Table of Contents Refrigeration Cycle Service Procedures Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8) Solving Problems Identifying Low System Charge (9-11) Identifying High

More information

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER Room Air Conditioner Installation and Operation Manual UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER (VOLTS) MIN. MAX. MIN. F ( C) MAX. F ( C) WAC060K7A 127-1-60 114.3 139.7 70(20.1)

More information

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL BD-150 (1025000) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL BD-150 OWNERS MANUAL Page 1 of 12 INTRODUCTION Designed for a wide range of applications, the BD-150 dehumidifier is a super high capacity

More information

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page

More information

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 8 Product Support Questions: Contact Ebac USA at (757) 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N V-SERIES Air Conditioner VA08 Model INSTRUCTION MANUAL Rev. F P/N 90164959 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D User Manual Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D Commercial Reach-In Freezers: FZ-1D, FZ-2D This manual contains important information about your new Admiral Craft refrigerated unit.

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338 TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976H207 (10-06) PP TABLE OF CONTENTS I. General

More information

Operating & Maintenance Manual for Islandaire Packaged Terminal Thru-Wall Air Conditioners & Heat Pumps

Operating & Maintenance Manual for Islandaire Packaged Terminal Thru-Wall Air Conditioners & Heat Pumps Operating & Maintenance Manual for Islandaire Packaged Terminal Thru-Wall Air Conditioners & Heat Pumps *THIS BOOK CONTAINS INFORMATION ON THE OPERATION OF YOUR UNIT. KEEP IN A SAFE PLACE FOR READY REFERENCE.

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510 TECHNICAL & SERVICE MANUAL SA 93AH FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-93AH 1 851 006 97 Australia SA 93AH REFERENCE NO. SM700510 IMPORTANT! Please Read Before

More information

PARTS LIST 26TTW09 AC230V1 A 26TTW09 HC230V1 A

PARTS LIST 26TTW09 AC230V1 A 26TTW09 HC230V1 A Through-The-Wall ir Conditioner NO Part Code Part Description 26TTW07 HP230V1 C115V1 PRTS LIST C230V1 HC230V1 HP115V1 HP230V1 C115V1 C230V1 HC230V1 1 00018900002 LCD Cover Sub-assy 1 00018900003 LCD Cover

More information

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD60 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the CD60 dehumidifier is a rugged, industrial unit which utilizes

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. I P/N 89104461 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation

SERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation ROOM AIR CONDITIONER AW079 AW089 SERVICE Manual AIR CONDITIONER CONTENTS. Precautions 2. Product Specifications 3. Operating Instructions and Installation 4. Disassembly and Reassembly 5. Troubleshooting

More information

SERVICE MANUAL CAUTION

SERVICE MANUAL CAUTION WEBSITE E-MAIL http://biz.lgservice.com http://www.lgeservice.com/techsup.html Room Air Conditioner SERVICE MANUAL CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. - ONLY

More information

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL NEPTUNE OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the Neptune dehumidifier is a super high capacity industrial

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015 Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T50 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-203 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services GE Zoneline vertical packaged terminal air conditioners 2010 Home Products and Services Appearance All the benefits of PTAC with the aesthetics and versatility of central air. Zoneline vertical units provide

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT DocID: 00G00089E 2012 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MBDQ Ducted Style Ductless System Sizes 18 to 48 Owner s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6 INTRODUCTION This service manual covers the installation, operation, maintenance and service of this ice machine. Table of Contents SPECIFICATIONS Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4

More information

Use & Care. Room Air Conditioner. All about the. of your TABLE OF CONTENTS. Normal Sounds... 4 Major Appliance Limited Warranty...

Use & Care. Room Air Conditioner. All about the. of your TABLE OF CONTENTS. Normal Sounds... 4 Major Appliance Limited Warranty... All about the Use & Care of your Room Air Conditioner TABLE OF CONTENTS Important Safety Instructions... 2-3 Care and Cleaning... 6 Product Registration... 4 Energy Saving Ideas... 6 Packaging... 4 Before

More information

LG Room Air Conditioner

LG Room Air Conditioner website http://www.lgservice.com LG Room Air Conditioner SERVICE MANUAL MODEL: LW2414HR CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL.

More information

Room Air Conditioner Service and Parts Manual

Room Air Conditioner Service and Parts Manual Fan Only Cool Dry Money Saver Temp Room Air Conditioner Service and Parts Manual Mode Timer 0n/ 0ff 0F hr Fan Speed Auto Swing Power CP10E10 CP12E10 CP10 CP12 SVC PARTS 2008 (07/08) Air Conditioner Service

More information

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB Service Manual Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB TABLE OF CONTENT TABLE OF CONTENT... 1 SPECIFICATION... 1 OUTLINE AND INSTALLATION DIMENSION... 3 REFRIGERATION SYSTEM DIAGRAM... 6 WIRING

More information

Servi. Sli e C Air C. Amana AAC081SRA AAC101SRA AAC121SRA AAC141SRA AAC182SRA AAC202SRA AAC242SRA

Servi. Sli e C Air C. Amana AAC081SRA AAC101SRA AAC121SRA AAC141SRA AAC182SRA AAC202SRA AAC242SRA Servi This manual is to be used by qualified appliance technicians only. Maytag does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified

More information

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MB*D Ducted Style Ductless System Sizes 09 to 48 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI NO. S051-800 ISSUED: MAR. 26, 2010 REVISED: HOSHIZAKI COUNTER SHOWCASE MODEL HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B SERVICE MANUAL IMPORTANT This manual should be read carefully

More information

A/C-HEATER SYSTEM - MANUAL

A/C-HEATER SYSTEM - MANUAL A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,

More information

ELECTRONIC CONTROL AIR CONDITIONER

ELECTRONIC CONTROL AIR CONDITIONER USE & CARE MANUAL NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are

More information

AC-12200E Portable Air Conditioner

AC-12200E Portable Air Conditioner AC-12200E Portable Air Conditioner OWNERS MANUAL Read and save these instructions. A Name You Can Trust Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. 2

More information

Instruction Manual Item No.: V~, 60Hz

Instruction Manual Item No.: V~, 60Hz Energy- Saving Mode Portable AC 8,000 BTU Model: MW-O-08C Montgomery Ward Customer Service 1112 7th Avenue, Monroe, WI 53566 8:00 am to Midnight, Monday through Friday Wards.com 1 888 557 3848 Instruction

More information

KM-61BAH KM-101BAH KM-151BAH

KM-61BAH KM-101BAH KM-151BAH NO. M006-749 ISSUED: FEB. 18, 2008 REVISED: JUN. 12, 2008 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER MODEL KM-61BAH KM-101BAH KM-151BAH SERVICE MANUAL IMPORTANT Only qualified service technicians should attempt

More information

TECHNICAL SERVICE GUIDE

TECHNICAL SERVICE GUIDE GE Consumer Home Services Training TECHNICAL SERVICE GUIDE Zoneline Vertical Air Conditioners Case Zoneline unit Front MODEL SERIES: AZE09DAC AZH09DAC AZE09EAC AZH09EAC AZEDAC AZHDAC AZEEAC AZHEAC AZEDAC

More information

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS Owner s Manual CR2500ACH CR5000ACH Portable Heating and Air Conditioning Unit Version 02 Table of Contents 1. SAFETY INSTRUCTIONS... 1-1 CAREFULLY READ THESE INSTRUCTIONS BEFORE USING... 1-1 SAFETY PRECAUTIONS...

More information