Instruction Manual. Vapour Pump Thermal Snap-Switches. Cooling-Fail Thermal Snap-Switch

Size: px
Start display at page:

Download "Instruction Manual. Vapour Pump Thermal Snap-Switches. Cooling-Fail Thermal Snap-Switch"

Transcription

1 Instruction Manual B Issue E Original Vapour Pump Thermal Snap-Switches Description Cooling-Fail Thermal Snap-Switch Cooling-Fail Thermal Snap-Switch Cooling-Fail Thermal Snap-Switch Pump-Ready Thermal Snap-Switch Boiler-Protection Thermal Snap-Switch Item Number B B B B B

2 Important safety Information Vacuum pumps are potentially dangerous if incorrectly used, repaired or maintained, so please approach the repair or maintenance with caution. Any incorrectly fitted spare parts could damage your pump and could be potentially dangerous. Never allow unqualified personnel to attempt to remove or replace any part of the pump. If you have any doubts about the servicing procedures or the products capabilities please contact Edwards. Before returning any equipment to Edwards for repair please follow the Edwards HS1 procedure and complete an HS2 declaration form to warn of any substances used or produced in the equipment that can be dangerous. The procedure and forms are included with the pump instruction manuals and can be downloaded together with Edwards local contact details from Always conform to service schedules unless adverse conditions necessitate more frequent servicing. Report any defect before an accident or consequential damage can occur. Observe local and country specific regulations, norms and guidelines. Never allow anyone to remove large or heavy components without adequate lifting equipment. Before maintenance work is begun, ensure the pump is switched off and isolated from the mains. The pump may have been exposed to processes which use hazardous substances or produces by-products which are dangerous to human health and safety, for example, chemically active, biologically active or radioactive substances. Before working on a pump, ensure that the correct personal protective equipment is available and being used. Always wear safety goggles. Wear a breather mask with positive air pressure and take other precautions if you believe the pump may be contaminated with hazardous substances and dusts. When applying sealants and lubricants, prevent contact with the skin by wearing suitable gloves. Seals may contain fluoroelastomer, which when properly handled is not dangerous but which may produce a toxic and corrosive residue (hydrogen fluoride or hydrofluoric acid) in the event of excessive heat or fire depending on the circumstances of degradation and other materials involved. On completion of maintenance, check the pump functions correctly and that all guards and protection devices are fitted and working correctly and that the pump is electrically safe. If the pump is used for handling hazardous substances check the pump for leak-tightness before use. Dispose of waste oil and any process by-products in accordance with local and national safety and environmental requirements. It is usually illegal to dispose of waste oil into drains or water courses, or to bury it. Edwards Limited Manor Royal Crawley, West Sussex, UK RH10 9LW Tel: +(44) Fax: +(44) Edwards Limited Edwards and the Edwards logo are trademarks of Edwards Limited.

3 Contents Section Page 1 Introduction... 1 Contents 2 Pump-Ready Thermal Snap-Switch Description Technical data Installation Unpack and inspect Fit the Pump-Ready Thermal Snap-Switch to the pump Operation Cooling-Fail Thermal Snap-Switches Description Technical data Installation Unpack and inspect Fit Cooling-Fail Thermal Snap-Switch B to the pump Cooling-Fail Thermal Snap-Switch B electrical connections Fit Cooling-Fail Thermal Snap-Switches B and B to the pump Operation Boiler-Protection Thermal Snap-Switch Description Technical data Installation Unpack and inspect Fit the Boiler-Protection Thermal Snap-Switch to the pump Operation Maintenance Ipsitech 9001(21)-2008 Edwards Limited All rights reserved. Page i

4 Contents Illustrations Figure Page 1 Pump-Ready Thermal Snap-Switch dimensions (mm) Cooling-Fail Thermal Snap-Switch B dimensions (mm) Cooling-Fail Thermal Snap-Switches B and B dimensions (mm) Component parts of Cooling-Fail Thermal Snap-Switch B Method of mounting the Cooling-Fail Thermal Snap-Switch B Boiler-Protection Thermal Snap-Switch dimensions (mm)...11 Tables Table Page 1 Pump-Ready Thermal Snap-Switch technical data Pump-Ready Thermal Snap-Switch checklist of items Cooling-Fail Thermal Snap-Switches technical data Cooling-Fail Thermal Snap-Switch B checklist of items Cooling-Fail Thermal Snap-Switches B and B checklist of items Boiler-Protection Thermal Snap-Switch technical data Boiler-Protection Thermal Snap-Switch checklist of items...10 Page ii Edwards Limited All rights reserved.

5 1 Introduction This manual provides installation, operation and maintenance instructions for the Edwards Cooling-Fail, Pump-Ready and Boiler-Protection Thermal Snap- Switches. You must use the thermal snap-switches as described in this manual. Read this manual and the instruction manual supplied with your vapour pump before you install and use the thermal snap-switches. Important safety information is highlighted as WARNING and CAUTION instructions; you must obey these instructions. The use of WARNINGS and CAUTIONS is defined below. Introduction WARNING Warnings are given where failure to observe the instruction could result in injury or death to people. CAUTION Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment and process. The following IEC warning label appears on the thermal snap-switches: Warning - risk of electric shock. The units used throughout this manual conform to the SI international system of units of measurement. Edwards Limited All rights reserved. Page 1

6 Pump-Ready Thermal Snap-Switch 2 Pump-Ready Thermal Snap-Switch 2.1 Description This snap-switch is mounted directly on Edwards vapour pumps. The snap-switch opens at a preset temperature to indicate that the pump is at operating temperature. The snap-switch can be used to control the opening of the pumping system high-vacuum valve. The Pump-Ready Thermal Snap-Switch is designed for use with the following Edwards vapour pumps : EO4/EO9 EO40/55 EO50/60 EO100/90 All Diffstak models SI Technical data Table 1 - Pump-Ready Thermal Snap-Switch technical data Dimensions See Figure 1 Electrical rating 6 A at 120 V a.c. resistive 3 A at 240 V a.c. resistive 7 A at 30 V a.c./d.c. resistive Contact opening temperature 80 ± 2.8 C Contact closing temperature 60 ± 2.8 C 2.3 Installation Unpack and inspect 1. Remove all packing materials and check the snap-switch. 2. If the snap-switch is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the snap-switch together with the order number and your supplier s invoice number. Retain all packing material for inspection. Do not use the snap-switch if it is damaged. 3. Check that your package contains the items listed in Table 1. If any of these items is missing, notify your supplier in writing within three days. Table 2 - Pump-Ready Thermal Snap-Switch checklist of items Quantity Description Check ( ) 1 Thermal Snap-Switch 2 Pan-head screws M3 x 5 Page 2 Edwards Limited All rights reserved.

7 2.3.2 Fit the Pump-Ready Thermal Snap-Switch to the pump The switch mounting plate has two 3.56 mm diameter holes designed to align with the standard mounting plates on Edwards vapour pumps (usually located on the backing-condenser). The procedure for installation of the snap-switch is as follows: 1. Apply a light coat of heat sink compound (Dow Corning 340 or other suitable alternative) to the contact face of the thermal snap-switch. 2. Locate the snap-switch over the correct mounting point (see the instruction manual supplied with your pump) with the mounting holes aligned. 3. Secure the snap-switch in place with the screws supplied. 4. Connect the snap-switch electrical signal leads to your control equipment. 2.4 Operation Once correctly installed, the snap-switch will operate automatically and requires no adjustment. The normally-closed snap-switch contacts will open at the specified temperature. Once the snap-switch cools, the contacts close again (that is, the snap-switch automatically resets) at the specified reset temperature. Refer to Section 2.2 for the opening and closing temperatures. Figure 1 - Pump-Ready Thermal Snap-Switch dimensions (mm) Pump-Ready Thermal Snap-Switch Edwards Limited All rights reserved. Page 3

8 Cooling-Fail Thermal Snap-Switches 3 Cooling-Fail Thermal Snap-Switches 3.1 Description These snap-switches are mounted directly on Edwards vapour pumps. The snap-switches open at a preset temperature to indicate failure of the cooling-water (or air) flow. These snap-switches will reset (that is, close again) when the pump cools down to a preset temperature. We therefore recommend that your control equipment incorporates a manual reset device to prevent automatic switchon of the pump again when it cools down. If you do not have a manual reset device (and the fault which caused the snap-switch to open has not been corrected), the pump will alternately switch on and off as it cools down and heats up again. Three models of Cooling-Fail Thermal Snap-Switch are available, for different Edwards vapour pumps, as follows: Item Number B B B Technical data Suitable for pumps EO40/55, EO50/60, EO100/90, SI100 All Diffstak models, EO2K (water and air-cooled), EO4K, EO6K, EO9K, EO12, EO16, EO20, EO400, F3605, 18B4A, 30B5A TVA50/60, TVW50/60 Table 3 - Cooling-Fail Thermal Snap-Switches technical data Snap-Switch B Dimensions See Figure 2 Electrical rating 25 A at 120 V a.c. 20 A at 240 V a.c. Contact opening temperature 46 ± 3 C Contact closing temperature 38 ± 3 C Snap-Switch B Dimensions See Figure 3 Electrical rating 15 A at 120 V a.c. resistive 10 A at 240 V a.c. resistive Contact opening temperature 50 ± 3 C Contact closing temperature 35 ± 3 C Snap-Switch B Dimensions See Figure 3 Electrical rating 15 A at 120 V a.c. resistive 10 A at 240 V a.c. resistive Contact opening temperature 60 ± 3 C Contact closing temperature 50 ± 3 C Page 4 Edwards Limited All rights reserved.

9 Figure 2 - Cooling-Fail Thermal Snap-Switch B dimensions (mm) Figure 3 - Cooling-Fail Thermal Snap-Switches B and B dimensions (mm) Cooling-Fail Thermal Snap-Switches Edwards Limited All rights reserved. Page 5

10 Cooling-Fail Thermal Snap-Switches 3.3 Installation Unpack and inspect 1. Remove all packing materials and check the snap-switch. 2. If the snap-switch is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the snap-switch together with the order number and your supplier s invoice number. Retain all packing material for inspection. Do not use the snap-switch if it is damaged. 3. Check that your package contains the items listed in the appropriate Table 4 or 5. If any of these items is missing, notify your supplier in writing within three days. Table 4 - Cooling-Fail Thermal Snap-Switch B checklist of items Quantity Description Check ( ) 1 Thermal Snap-Switch 2 Nylon spacers 1 20 mm lock-ring 1 Cable-gland 1 Conduit box 2 Cheese-head screws M4 x 16 1 Cheese-head screw M4 x 30 1 M4 nut 2 M4 plain washers 2 M4 spring washers 1 M4 shake-proof washer 1 Spacer Table 5 - Cooling-Fail Thermal Snap-Switches B and B checklist of items Quantity Description Check ( ) 1 Thermal Snap-Switch 2 Pan-head screws M3 x 5 Page 6 Edwards Limited All rights reserved.

11 3.3.2 Fit Cooling-Fail Thermal Snap-Switch B to the pump The component parts of the thermal snap-switch are shown in Figure 4. The method used to secure the snap-switch is shown in Figure 5. Refer to the instruction manual supplied with your pump for the correct location of the snapswitch. 1. Refer to Figure 5. Remove the conduit box cover, screw the cable-gland into the cable leadthrough hole in the box and secure with the plastic lock-ring. 2. Insert two M4 x 16 cheese-head screws through the mounting holes of the snap-switch. 3. Place the two plastic spacers over the screws, align and insert the snap- switch into the conduit box. 4. Lightly coat the snap-switch contact face with heat sink compound (Dow Corning 340 or suitable substitute). 5. Use M4 screws to secure the conduit box to the pump mounting plate Cooling-Fail Thermal Snap-Switch B electrical connections WARNING Incorporate a manual reset device in your control equipment. If you do not (and a fault which causes the snap-switch to open is not corrected), the pump will alternately switch on and off as it cools down and heats up again. WARNING You must use a suitable earth (ground) cable to connect the earth (ground) point on the thermal snap-switch mounting plate to the earth (ground) point in the pump electrical box. 1. If conduit is to be used to carry the snap-switch output signals, fit a male plastic bush (not supplied) to the interior of the conduit box. Cooling-Fail Thermal Snap-Switches 2. Pass the electrical signal cable(s) through the cable-gland and/or the male strain-relief gland (not supplied), then connect the cable(s) to the electrical terminals (see Figure 4, item 8). 3. Use a suitable earth (ground) cable to connect the earth (ground) point on the snap-switch mounting plate to the earth (ground) point in the electrical box of the pump: Refer to Figure 5 detail A for the positions of the earth (ground) points on the snap-switch mounting plate. Refer to Figure 5 details B and C for details of the connection of your earth (ground) wire to the earth (ground) point. Refer to the pump instruction manual for information on the earth (ground) connections on the pump. 4. Secure the cover to the conduit box. Edwards Limited All rights reserved. Page 7

12 Cooling-Fail Thermal Snap-Switches Figure 4 - Component parts of Cooling-Fail Thermal Snap-Switch B Conduit box 2. Spacer 3. Mounting screw 4. Diffusion pump mounting plate 5. Plastic lock-ring 6. Plastic female screwed bush 7. Conduit box cover 8. Electrical terminals Figure 5 - Method of mounting the Cooling-Fail Thermal Snap-Switch B A. Interior of the snap-switch B. Earth (ground) connection: option 1 C. Earth (ground) connection: option 2 1. Earth (ground) screw 2. Star washer 3. Spacer 4. Diffusion pump mounting plate 5. Conduit box 6. Plain washer 7. Nut Page 8 Edwards Limited All rights reserved.

13 3.3.4 Fit Cooling-Fail Thermal Snap-Switches B and B to the pump The snap-switch mounting plate has two 3.56 mm diameter holes which align with the standard mounting plates (which are located on the cooling-fins) on EO40/55, EO50/60, EO100/90, TVA50/60, TVW50/60 and SI100 vapour pumps. Install the snap-switch as follows : 1. Apply a light coat of heat sink compound (Dow Corning 340 or other suitable alternative) to the contact face of the thermal snap-switch. 2. Locate the snap-switch over the correct mounting point (see the instruction manual supplied with your pump) with the mounting holes aligned. 3. Secure the snap-switch in place with the screws supplied. 4. Connect the snap-switch electrical signal leads to your control equipment. 3.4 Operation WARNING Incorporate a manual reset device in your control equipment. If you do not (and a fault which causes the snap-switch to open is not corrected), the pump will alternately switch on and off as it cools down and heats up again. Once correctly installed, the snap-switch will operate automatically and require no adjustment. The normally-closed snap-switch contacts will open at the specified temperature. Once the snap-switch cools, the contacts close again (that is, the snap-switch automatically resets) at the specified reset temperature. Your control equipment must be suitable for this method of operation (see Section 3.1). Cooling-Fail Thermal Snap-Switches Refer to Section 3.2 for the contact opening and closing temperatures. Edwards Limited All rights reserved. Page 9

14 Boiler-Protection Thermal Snap-Switch 4 Boiler-Protection Thermal Snap-Switch 4.1 Description The Boiler-Protection Thermal Snap-Switch is mounted directly on Edwards vapour pumps. The snap-switch opens at a preset temperature when the pump boiler base exceeds the maximum safe operating temperature. The snap-switch will reset (that is, close again) when the pump cools down to a preset temperature. We therefore recommend that your control equipment incorporates a manual reset device to prevent automatic switch-on of the pump again when it cools down. If you do not have a manual reset device (and the fault which caused the snap-switch to open has not been corrected), the pump will alternately switch on and off as it cools down and heats up again. The Boiler-Protection Thermal Snap-Switch is designed for use with the Edwards EO40/55, EO50/60 and SI100 vapour pumps. 4.2 Technical data 4.3 Installation Unpack and inspect Table 6 - Boiler-Protection Thermal Snap-Switch technical data Dimensions See Figure 6 Electrical rating 15 A at 220 V a.c. 50/60 Hz 10 A at 240 V a.c. 50/60 Hz Contact opening temperature 200 ± 4.4 C Contact closing temperature 184 ± 4.4 C 1. Remove all packing materials and check the snap-switch. 2. If the snap-switch is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the snap-switch together with the order number and your supplier s invoice number. Retain all packing material for inspection. Do not use the snap-switch if it is damaged. 3. Check that your package contains the items listed in Table 7. If any of these items is missing, notify your supplier in writing within three days. Table 7 - Boiler-Protection Thermal Snap-Switch checklist of items Quantity Description Check ( ) 1 Thermal Snap-Switch 2 Pan-head screws M3 x 5 Page 10 Edwards Limited All rights reserved.

15 4.3.2 Fit the Boiler-Protection Thermal Snap-Switch to the pump The snap-switch mounting plate has two 3.56 mm diameter holes which align with any pair of the four tapped holes in the pump-ready thermal snap-switch mounting plate of the EO40/55, EO50/60 and SI100 vapour pumps. This allows you to fit a Boiler-Protection Thermal Snap-Switch and a Pump-Ready Thermal Snap-Switch at the same time, while a tapped hole will still be available as an earthing (grounding) point for the pump body. Install the snap-switch as follows : WARNING Incorporate a manual reset device in your control equipment. If you do not (and a fault which causes the snap-switch to open is not corrected), the pump will alternately switch on and off as it cools down and heats up again. 1. Apply a light coat of heat sink compound (Dow Corning 340 or other suitable alternative) to the contact face of the thermal snap-switch. 2. Locate the snap-switch over the correct mounting point (see the instruction manual supplied with your pump) with the mounting holes aligned. You can use any of the four holes. 3. Secure the snap-switch in place with the screw supplied. 4. Connect the snap-switch electrical signal leads to your control equipment. Figure 6 - Boiler-Protection Thermal Snap-Switch dimensions (mm) Boiler-Protection Thermal Snap-Switch Edwards Limited All rights reserved. Page 11

16 Boiler-Protection Thermal Snap-Switch 4.4 Operation Once correctly installed, the snap-switch will operate automatically and require no adjustment. The normally-closed snap-switch contacts will open at the specified temperature. Once the snap-switch cools, the contacts close again (that is, the snap-switch automatically resets) at the specified reset temperature. Your control equipment must be suitable for this method of operation (see Section 4.1). Refer to Section 4.2 for the contact opening and closing temperatures. Page 12 Edwards Limited All rights reserved.

17 5 Maintenance The snap-switches require no regular maintenance. We recommend that, as part of your normal regular vapour pump maintenance, you check the electrical connections to ensure that they remain secure. Maintenance Edwards Limited All rights reserved. Page 13

18 This page has been intentionally left blank. Page 14 Edwards Limited All rights reserved.

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap Instruction Manual A441-01-880 Issue F IT20K, IT100, IT300 and IT800 Inlet Traps Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet Desiccant Trap ITF20K Inlet Dust Filter ITO100

More information

Instruction Manual. M150 Gas Reactor Column. A Issue B

Instruction Manual. M150 Gas Reactor Column. A Issue B A553-01-880 Issue B Instruction Manual M150 Gas Reactor Column Manor Royal, Crawley, West Sussex, RH10 2LW, UK Telephone: +44 (0) 1293 528844 Fax: +44 (0) 1293 533453 http://www.bocedwards.com Declaration

More information

Scientific vapor pumps

Scientific vapor pumps Scientific vapor pumps Vapor pumps for scientific instruments and R&D applications Diffusion pumps - technology and applications - EO series -4 Diffstak -8 Cryo cooled diffstak - Unvalved diffstak -6 Diffstak

More information

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. idealvac.com (505) idealvac.com. ITC800 Inlet Chemical Trap Instruction Manual A441-01-880 Issue G Original IT20K, IT100, IT300 and IT800 Inlet Traps idealvac.com (505)872-0037 idealvac.com Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet

More information

DUST EXTRACTOR MODEL No: CDE1000

DUST EXTRACTOR MODEL No: CDE1000 DUST EXTRACTOR MODEL No: CDE000 Part No:64765 OPERATING & MAINTENANCE INSTRUCTIONS GC054 INTRODUCTION Thank you for purchasing this CLARKE Dust Extractor which is intended to keep work areas free from

More information

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9 3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL Model # 4KTV9 QUALITY GUARANTEE: Should a Westward product fail to perform satisfactorily due to defect or poor workmanship within one

More information

MOBILE PARTS WASHER MODEL No: CWM20

MOBILE PARTS WASHER MODEL No: CWM20 MOBILE PARTS WASHER MODEL No: CWM20 Part No: 7630925 OPERATING & MAINTENANCE INSTRUCTIONS GC0514 INTRODUCTION Thank you for purchasing this CLARKE mobile parts washer. Before use, please read this instruction

More information

Installation Instructions

Installation Instructions 48/50A2,A3,A4,A5020-060, 48/50P2,P3,P4,P5030-100, 48/50N 75 to 105 Ton Return Smoke Detector Accessory Installation Instructions Part No. CRSMKDET002C00 CONTENTS GENERAL........................................

More information

MODEL # PUMA G, 3-SPEED TRANSPORTABLE AIR MOVER

MODEL # PUMA G, 3-SPEED TRANSPORTABLE AIR MOVER OWNER S MANUAL IMPORTANT: READ OWNER S MANUAL CAREFULLY MODEL # PUMA G, 3-SPEED TRANSPORTABLE AIR MOVER FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL: SERIAL NUMBER: DATE PURCHASED:

More information

Thermo-Sealer. Manual Heat Sealer. User Manual

Thermo-Sealer. Manual Heat Sealer. User Manual Thermo-Sealer Manual Heat Sealer User Manual Thermo-Sealer Contents Page Page Introduction 2 Safety 2 Declaration of conformity 3 Caution and safety signs in accordance with IEC 417 4 Unpacking 4 Technical

More information

POWER CUT Hedge Trimmer 46 Model No. 101HT450

POWER CUT Hedge Trimmer 46 Model No. 101HT450 POWER CUT Hedge Trimmer 46 Model No. 101HT450 Operator s Manual To reduce the risk of injury, the user must read and understand the Operator s Manual. Keep these instructions for future reference. Introduction

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843

ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR. FOX Model F50-843 ASSEMBLY AND OPERATING INSTRUCTIONS 3HP DUST EXTRACTOR FOX Model F50-843 1 3hp Dust Extractor FOX MODEL F50-843 TABLE OF CONTENTS Safety instructions Page 3 Specific safety instructions for dust collectors.page

More information

LS-JRE OPERATION & INSTRUCTION MANUAL

LS-JRE OPERATION & INSTRUCTION MANUAL SOLVENT RECYCLING SYSTEM LS-JRE OPERATION & INSTRUCTION MANUAL Now with adjustable temperature control! TABLE OF CONTENTS Description Page Introduction 1 Safety Precautions 1 Installation / Set-up 1 Supplied

More information

Installation and Wiring Instructions

Installation and Wiring Instructions Powerline (TDF) Installation and Wiring Instructions TDF32014 TDF38014 TDF42014 TDF48014 TDF38034 TDF42034 TDF48034 TDF52034 TDF52036 TDF60034 TDF60036 PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING

More information

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP INSTRUCTIONS FOR INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP MODEL NO: PC200SDAUTO.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according

More information

ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR. FOX Model F50-841

ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR. FOX Model F50-841 ASSEMBLY AND OPERATING INSTRUCTIONS 1HP DUST EXTRACTOR FOX Model F50-841 1 1hp Dust Extractor FOX MODEL F50-841 TABLE OF CONTENTS Safety instructions Page 3 Specific safety instructions for dust collectors.page

More information

Electrical Safety Requirements

Electrical Safety Requirements Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system

More information

Technology for Vacuum Systems. Instructions for use

Technology for Vacuum Systems. Instructions for use page 1 of 8 Technology for Vacuum Systems Instructions for use GKF 1000i Cold trap page 2 of 8 Content Safety information!...3 General information...3 Intended use...3 Setting up and installing the cold

More information

POWER CUT Cordless Hedge Trimmer Model No. 101HT18V

POWER CUT Cordless Hedge Trimmer Model No. 101HT18V POWER CUT Cordless Hedge Trimmer Model No. 101HT18V Operator s Manual WARNING To reduce the risk of injury, the user must read and understand the Operator s Manual. Keep these instructions for future reference.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FCB Pinnacle 4 Flavor Wide Body Units Thermostat Reset Upgrade Kit P/N 629088712 Release Date: January 23, 2006 Publication Number: 629088712INS Revision Date: March 24, 2014

More information

USER S MANUAL ATH WH220

USER S MANUAL ATH WH220 USER S MANUAL ATH WH220 INDEX INTRODUCTION... - 3 - General information s... - 3 - Description of pneumatic jack... - 4 - Operation of jack... - 5 - Technical data... - 6 - Dimension drawing... - 6 - INSTALLATION...

More information

100T Electric Shop Press

100T Electric Shop Press 100T Electric Shop Press Operation Manual 1 Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations

More information

150T Electric Shop Press

150T Electric Shop Press 150T Electric Shop Press Operation Manual 1 Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations

More information

Instruction Manual. B Issue B. next Pump Accessories

Instruction Manual. B Issue B. next Pump Accessories Instruction Manual B811-00-880 Issue B next Pump Accessories This page has been intentionally left blank. Contents Section Page 1 Introduction... 1 Contents gea/0086/06/10 1.1 Scope and definitions...

More information

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual Model, 2025BN, 2025ST Staging Cabinets Instruction Manual Part No 53021 Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS DANGER Machine must be properly grounded to prevent electrical shock to personnel.

More information

SEALING FIBER SEALING COMPOUND

SEALING FIBER SEALING COMPOUND ARCTIC TRACE INSTALLATION INSTRUCTIONS Type GUAT26C Hazardous Location Power Connection and Butt Splice Kit for Temperature Limiting Submersible Heating Cable JUNCTION BOX SEALING FIBER SEAL OFF SEALING

More information

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration. MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK IMPORTANT: This booklet should be given to the customer after installation and demonstration. Description of water heater 1) Hot water outlet 2) Temperature

More information

OWNERS MANUAL MODEL: Steamer PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD.

OWNERS MANUAL MODEL: Steamer PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD. OWNERS MANUAL MODEL: CHILI/CHEESE WARMER Steamer PART NUMBER: 51072 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH. WARNING:

More information

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop Instruction Manual Cheddar Easy All-In-One Cheese Corn Shop Model No. 2703-00-000 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 110028 SAFETY PRECAUTIONS

More information

Aluminum Heating Mantles

Aluminum Heating Mantles Aluminum Heating Mantles ON/OFF HOT User Guide Version 1.3 ON/OFF IEC power inlet socket Power supply switch (large-volume models). Power to either the lower part of the element or the upper and lower

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan

1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan 1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan Hand Dryer Model JT-SB216ESH-W-CE Installation Manual Single-phase 220-240VAC For dealers and installers The Instruction Manual and Usage Sticker

More information

Sip Vacuum Cleaner 1400/35 Wet & Dry

Sip Vacuum Cleaner 1400/35 Wet & Dry Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

hp Dust Collector With Vacuum Attachment

hp Dust Collector With Vacuum Attachment Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

UV Lamp and Quartz Sleeve Replacement/Maintenance

UV Lamp and Quartz Sleeve Replacement/Maintenance UV Lamp and Quartz Sleeve Replacement/Maintenance Models: Tap, Tap Plus, Home, Home Plus, Professional, Professional Plus (Excluding, D4, E4, F4, and Plus and Monitored versions) Overview UV Lamp replacement:

More information

Field Top Mounted Condensing Unit

Field Top Mounted Condensing Unit Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference! REVISION HISTORY VERSION 1.0 New manual This manual is specific to the

More information

MIX Boiler & Font Range Service Manual

MIX Boiler & Font Range Service Manual MIX Boiler & Font Range Service Manual 1000870# 1000871# 1000875# 1000880# 1000887# 1000878 1000879 2300268 www.marcobeveragesystems.com Ireland Tel: +353 (1) 295 2674 UK Tel: +44 (0207) 2744577 Service

More information

Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer) Panel Fan Series Operators Manual (Galvanized and Polymer) 52" Belt Drive, Galvanized Panel Fan with Three Wing Blade IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before

More information

Mix Boiler & Font Range ( #, #, #, , )

Mix Boiler & Font Range ( #, #, #, , ) Mix Boiler & Font Range (1000870#, 1000871#, 1000880#, 1000878, 1000879) Service Manual Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland Ireland

More information

Spiral Dough Mixer. Instruction manual. Model: CP821

Spiral Dough Mixer. Instruction manual. Model: CP821 Spiral Dough Mixer Instruction manual Model: CP821 SPARE PARTS LIST OF CP821 NO. Description QTY. NO. Description QTY. 1. Small chain wheel of main shaft 1 29. Chain 06B-1-70L 2 2. Big chain wheel 3 30.

More information

Betriebsanleitung Operating Instructions

Betriebsanleitung Operating Instructions Betriebsanleitung Operating Instructions Oil mist filter idealvac.com (505)872-0037 idealvac.com ONF 16 PK 0213 BE/G (0811) ONF 25/25L/25XL Table of contents Table of contents 1 About this manual......................................

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

SHORT WAVE INFRARED PANEL DRYER

SHORT WAVE INFRARED PANEL DRYER INSTRUCTIONS FOR: SHORT WAVE INFRARED PANEL DRYER MODEL: IR3000 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and

More information

Instruction Manual. Double Candy Apple Cooker

Instruction Manual. Double Candy Apple Cooker Instruction Manual Double Candy Apple Cooker Model No. 4416 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2014 Gold Medal Products Co. Part No. 46841 SAFETY PRECAUTIONS DANGER Machine must be

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

6 Oz. Twin Pop. Popcorn Machine Instruction Manual Model #2666EX. Cincinnati, OH USA. Part No EX Revised June 1996

6 Oz. Twin Pop. Popcorn Machine Instruction Manual Model #2666EX. Cincinnati, OH USA. Part No EX Revised June 1996 Popcorn Machine Instruction Manual Model #2666EX Part No. 16169EX Revised June 1996 Cincinnati, OH 45214-2089 USA SAFETY PRECAUTIONS This equipment is designed and sold for commercial use only. This equipment

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS 17 West Street West Hatfield, MA 01088 Phone: (413) 247-3380 * (800) 582-8423 Fax: (413) 247-3369 E-mail: info@stiebel-eltron-usa.com SB 150, SB 200 Glass Lined Indirectly Fired Water Heaters With Single

More information

PARTS WASHER Model: CW1D Part No:

PARTS WASHER Model: CW1D Part No: PARTS WASHER Model: CW1D Part No: 7630900 OPERATING & MAINTENANCE INSTRUCTIONS GC01/12 INTRODUCTION Thank you for purchasing this CLARKE Parts Washer. Before using the product, be sure to read these instructions

More information

Instruction Manual. Cheese Warmer with Pump

Instruction Manual. Cheese Warmer with Pump Instruction Manual Cheese Warmer with Pump 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2013 Gold Medal Products Co. Part No. 38298 SAFETY PRECAUTIONS Page 2 INSTALLATION INSTRUCTIONS Inspection

More information

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN PREMIUM KITCHEN MIXER TAP PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN 282471 GB/IE/NI Assembly, operating and safety instructions Page 5 B 15mm HG00476A HG00476B C 5 4 12

More information

3-1/2 Gallon Parts Washer

3-1/2 Gallon Parts Washer 3-1/2 Gallon Parts Washer Model 38347 Assembly and Operating Instructions 3491 Mission Oaks Blvd., Camarillo, CA 93011 Copyright 1998 by Harbor Freight Tools. All rights reserved. No portion of this manual

More information

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller INSTRUCTIONS OJ-DV-Relay-Module 67439B 10/16 (OSH) 016 OJ Electronics A/S Optional module for OJ-DV motor controller OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS Contents 1. Product

More information

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here: DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com

More information

PWASH Gallon Parts Washer Assembly & Operating Instructions

PWASH Gallon Parts Washer Assembly & Operating Instructions PWASH20 20 Gallon Parts Washer Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important

More information

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS FAN HEATER Models: DEVIL 4035 4055 4090 4115 OPERATING & MAINTENANCE INSTRUCTIONS 0705 DECLARATION of CONFORMITY We declare that this product complies with the following standards/directives: 73/23/EEC

More information

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE 1900097 1JET6 TWIN CONTENT PAGE INFORMATION 3 INSTALLATION 6 BREWER GRINDER 6 7 BREWER SETUP 11 BREWING 12 MANUAL MODE DILUTION GRINDER MODE PACKS MODE 12 14 15 17 CLEANING 19 KEY READ OPERATORS MANUAL

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

POWER SWEEP N VAC 1800W Model No. 101BV1800

POWER SWEEP N VAC 1800W Model No. 101BV1800 POWER SWEEP N VAC 1800W Model No. 101BV1800 Operator s Manual WARNING To reduce the risk of injury, the user must read and understand the Operator s Manual. Save this manual. Introduction Thank you for

More information

Thermal Stability Systems

Thermal Stability Systems Thermal Stability Systems for Oil Tank Heating Unit Model: TSSHU6002 PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE RETAINED FOR FUTURE

More information

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916 VACUUM EXTRACTOR MODEL NO: CWVE1 PART NO: 6471168 OPERATING & MAINTENANCE INSTRUCTIONS GC0916 INTRODUCTION Thank you for purchasing this CLARKE Workshop Vacuum Extractor. Before attempting to use this

More information

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 EKF EC kitchen extract fan range Installation and Wiring Instructions Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS.

More information

Model 400 Series Lights Installation Instructions

Model 400 Series Lights Installation Instructions Model 400 Series Lights Installation Instructions 256A424G REV. A 610 Printed in U.S.A. Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under the following conditions

More information

PARTS WASHER Model: CW2D Part No:

PARTS WASHER Model: CW2D Part No: PARTS WASHER Model: CW2D Part No: 7630910 OPERATING & MAINTENANCE INSTRUCTIONS GC01/12 INTRODUCTION Thank you for purchasing this CLARKE Parts Washer. Before using the product, be sure to read these instructions

More information

Friwa Compact. Operating instructions EN

Friwa Compact. Operating instructions EN Operating instructions EN Version 1.1 / Edition 09/2013 Contents 1 Key background information... 3 1.1 Limitation of liability... 3 1.2 Responsibilities of the operator... 3 1.3 Documentation... 3 1.3.1

More information

Mini-Rooter Operating Instructions

Mini-Rooter Operating Instructions Mini-Rooter Operating Instructions For 1-1/4 through 4 lines (30mm 100mm) Your Mini-Rooter is designed to give you years of trouble-free, profitable service. However, no machine is better than its operator.

More information

User s Manual and Operating Instructions

User s Manual and Operating Instructions User s Manual and Operating Instructions Model Numbers: CL-30P-DDF, CL-20F-DDF, CL-24O-DDF, CL-30-DDF READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual

More information

TDS 100. EN Operating Manual Electrical Fan Heater

TDS 100. EN Operating Manual Electrical Fan Heater TDS 100 EN Operating Manual Electrical Fan Heater TRT-BA-TDS 100 -TC-001-EN TROTEC GmbH & Co. KG Grebbener Straße 7 D-52525 Heinsberg Tel.: +49 2452 962-400 Fax: +49 2452 962-200 www.trotec.com E-Mail:

More information

WYND DC 54 CEILING FAN Installation Manual

WYND DC 54 CEILING FAN Installation Manual WYND DC 54 CEILING FAN Installation Manual CFFCWY4XXX Remote control included YOUR FANCO WYND 54 DC CEILING FAN Congratulations on purchasing your new Fanco Wynd 54 DC Ceiling Fan. Before attempting to

More information

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP100A, DWP150A, DWP200A PART NO: 7230098, 7230099, 7230100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117 - ISS 2 INTRODUCTION Thank you for

More information

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer) Galvanized Panel Fan IMPORTANT: READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before attempting to assemble, install, operate

More information

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment This manual is Copyright 2019 Duke Manufacturing Co.

More information

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU Moduflex Dry Air System Desiccant Air P3TJA13A1AN - P3TJA13A7AN EN USER GUIDE (Original Language) NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU LV LT RU SL TR MT CONTENTS 1 Safety Information...2 1.1

More information

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1 Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1 Introduction Congratulations on the choice of an Australian made quality product. Labec products are manufactured, tested and calibrated

More information

Instruction Manual. Astro Staging Cabinet

Instruction Manual. Astro Staging Cabinet Instruction Manual Astro Staging Cabinet 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 40269 SAFETY PRECAUTIONS DANGER Machine must be properly grounded to

More information

User and maintenance manual

User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS HIGHLY IMPORTANT. This manual and

More information

HPS TM Products Series 45. Vacuum Line Heaters OPERATION AND MAINTENANCE MANUAL

HPS TM Products Series 45. Vacuum Line Heaters OPERATION AND MAINTENANCE MANUAL HPS TM Products Series 45 s OPERATION AND MAINTENANCE MANUAL Please Note: MKS Instruments provides these documents as the latest version for the revision indicated. The material is subject to change without

More information

5HP CYCLONE DUST COLLECTOR MANUAL

5HP CYCLONE DUST COLLECTOR MANUAL 5HP CYCLONE DUST COLLECTOR MANUAL LAGUNA TOOLS 2072 Alton Parkway Irvine, California 92606 Ph: 800.234.1976 www.lagunatools.com 2018, Laguna Tools, Inc. LAGUNA and the LAGUNA Logo are the registered trademarks

More information

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display) Fault Indicators MN320004EN Effective March 2017 Supersedes August 2004 (S320-42-2) S.T.A.R. TM Fiber optic cable installation instructions COOPER POWER SERIES Fiber optic fitting (To led display) Mounting

More information

50T Electric Shop Press

50T Electric Shop Press 50T Electric Shop Press Operation Manual 1 Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations

More information

Installation & Operation Manual Models:

Installation & Operation Manual Models: SJS-I-O Rev C Installation & Operation Manual Models: 60-119 : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss

More information

3.5 GALLON PARTS WASHER

3.5 GALLON PARTS WASHER 3.5 GALLON PARTS WASHER Assembly and Operating Instructions 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 1997 by Harbor Freight Tools. All rights

More information

CHIPPER PC1 INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE. Series 35

CHIPPER PC1 INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE. Series 35 Cl/SfB (73.4) X CHIPPER PC1 INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE Series 35 Imperial Machine Company (Peelers) Limited Harvey Road, Croxley Green, Herts WD3 3AX, England Telephone: 01923

More information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright

More information

AHU INSTALLATION & OPERATION MANUAL

AHU INSTALLATION & OPERATION MANUAL AHU INSTALLATION & OPERATION MANUAL VERSION 2 AIR HANDLING UNIT MODELS: AHU 500, AHU 900, AHU 1200, AHU 1700, AHU 2000, AHU 2500, AHU3500, AHU 4500, AHU 5000, AHU 6000, AHU 7000, AHU 8000, AHU 10000, AHU

More information

Industrial Vacuums, Inc

Industrial Vacuums, Inc Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances

More information

SUPER T WALL FANS. Installation and Wiring Instructions

SUPER T WALL FANS. Installation and Wiring Instructions SUPR T WALL FANS Installation and Wiring Instructions Stock Ref. N 16 10 16 6 10 16 7 10 16 8 10 - Gravity Shutter Version (6 Pole) 16 7 10 16 67 10 16 77 10 16 87 10 - lectric Shutter Version (6 Pole)

More information

MERCURY HD-22 AUTOSCRUBBER Safe Operations

MERCURY HD-22 AUTOSCRUBBER Safe Operations Safe Operations PROPER OPERATING PROCEDURES By following proper operating procedures, the Mercury DS- 26 Autoscubber can provide you with productive, easy to operate, safe and clean floors. This machine

More information

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

SMHA Hatch High temperature fan HT-fan Installation and Maintenance High temperature fan HT-fan Installation and Maintenance 22.8.2012 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

Pump Out Vacuums Polyethylene & Steel

Pump Out Vacuums Polyethylene & Steel Pump Out Vacuums Polyethylene & Steel Operations and Parts Manual 110 volt receptacle on single motor only Models: 415P-AD 429P-AD 415DS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance,

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL CENTRAL FANS COLASIT LTD Unit 12A, Palmers Road, East Moons Moat, Redditch. Worcs. B98 0RF Tel: 01527-517200 Fax: 01527-517195 Edition 04_13 INSTALLATION, OPERATION & MAINTENANCE MANUAL CIV Fan Range Valid

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE

More information

Laundry Kit With flexi-neck faucet and storage cabinet

Laundry Kit With flexi-neck faucet and storage cabinet QL021 Owner s Manual Laundry Kit With flexi-neck faucet and storage cabinet Thank you for choosing Presenza Italia! We appreciate the trust and confidence you have placed in Presenza Italia through the

More information

Rycroft Supapac Plate Heat Exchangers

Rycroft Supapac Plate Heat Exchangers Rycroft Supapac Plate Heat Exchangers Installation Operation & Maintenance Manual Ormandy Rycroft Duncombe Road Bradford BD8 9TB England TEL +44 (0)1274 490911 FAX +44 (0)1274 498580 www.rycroft.com 1.

More information

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) Installation Manual For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC ) N404M.3 (128 liter 3-way operation with LP gas, 240 volts AC, or 12

More information

Installation Datasheet

Installation Datasheet Safegard EMB Installation Datasheet The panel is built to meet project specific requirements, see project drawings for details. This product forms part of a life safety system. Failure to correctly store,

More information

Installation, Operating and Servicing Instructions

Installation, Operating and Servicing Instructions Installation, Operating and Servicing Instructions Opus 700 Electric Pasta Boiler OE7701, OE7702 Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number:

More information

GL190-A / GL191-A / GJ461-A

GL190-A / GL191-A / GJ461-A Planetary Mixer Instruction manual Model: GL190-A / GL191-A / GJ461-A GL190-A_GL191_A_GJ461-A_A5_v3_170809.indb 1 2017/8/9 17:39 Exploded diagram and spare parts list GL190-A GL190-A_GL191_A_GJ461-A_A5_v3_170809.indb

More information

OPTIWAVE X500 Supplementary Instructions

OPTIWAVE X500 Supplementary Instructions OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information