1 Product Release Summary 48/50HC with System March 2012 TC

2 Benefits of EnergyX System Why Energy Recovery 1. Code requirements: ASHRAE : Energy Recovery is required when design supply air capacity is >5000 CFM & have 70% OA. ASHRAE : Significantly increases the application ranges where Energy Recovery is required. 2. Energy efficiency: System efficiencies as high as 18+ CEF (AHRI Guideline-V) 3. Utility Rebates 4. Expand the application range of base rooftop unit: Provide extra cooling, dehumidification & heating capacity OR Downsize base unit by using the ERV to pre-conditioning the ventilation air OR Allow the base unit to handle more ventilation airflow (and still meet design capacity & Leaving Air Temp requirements) 2

3 EnergyX System One Solid Line - Up WeatherMaster 48HC 3 25 Ton WeatherMaster 50HC 3 25 Ton Ton Size (17 size) ERV Only ERV with Enthalpy Econo ERV with Frost Protection ERV with Enthalpy Econo and Frost Protection - Available on 208/230/3/60, 460/3/60 and 575/3/60 models l - Not available on single phase 208/230/1/60 models - Not available on 50HCQ Heat Pumps These Sizes Released November

4 EnergyX System Features Energy (enthalpy) wheel that pre-cools, dehumidifies or pre-heats ventilation air prior to entering the evaporator coil. Energy Recovery system is rated and certified in accordance with AHRI Standard Helps reduce cooling load at design temperature up to 4 tons per 1000 cfm of outside air. Helps reduce heating load at design temperature up to 2.5 tons per 1000 cfm of outside air. 4

5 EnergyX System Features (cont) One single integrated HVAC comfort system that: Integrates controls for mechanical cooling, heating, ventilation and Energy Recovery Ventilation system. Provides the ability to have single source power supply and connection Provides a single piece for equipment for one time rigging and lifting at the job site Reduces the dual source logistic and technical issues common with separate field installation Pre engineered, assembled and tested at the factory prior to shipment. 5

6 EnergyX System Features (cont) Combined Efficiency Factor (CEF) up to ComfortLink controls Vertical duct air flow from factory field horizontal air flow adapter curb available Outside air and exhaust air cfm monitoring and display capabilities Variable speed energy recovery fans for Demand Control Ventilation (DCV) Uses standard roofcurbs no support rails or on site fabricated extensions True, wheel-bypass economizer option (factory installed only) 6

7 EnergyX System Overview 48/50HC - Rooftop Unit Modulating OA Dampers Indoor Fan RTU Heating Section Evapo rator Mixed Air = RA2 + Outdoor Air Pre-cooled, dehumidified and/or heated Ventilation Air ERV module Enthalpy wheel Outdoor Air Exhaust Air Supply Air Return Air / Exhaust Air Diverter Dampers RA2 RA1 Return Duct Replaceable Filters Airflow Sensing Module Unit Airflow (rear view) 7

8 EnergyX System Ease Of Set Up Enter: Commanded Exhaust Commanded Intake System: Modulating fans Intake damper Onboard airflow monitoring System works to balance actual and commanded Factory integrated system and controls Applies to EnergyX modulating CFM units only. 8

9 EnergyX System Ease Of Maintenance Easy access hinged door Filters slide out Energy Wheel slides out: Easy cleaning Sectional pie design 9

10 EnergyX System Onboard Airflow Monitoring Differential pressure sensed across window opening Correlation between differential pressure and CFM Intake/exhaust fans modulate: - Backward curved - Direct drive ECM motors Drive Actual CFM = Commanded CFM *Aluminum mist filter removed for photo Applies to EnergyX modulating CFM units only. 10

11 EnergyX System Integrated Controls CLv5 Outside Air Unit Points 48/50HC and ERV integrated control system ComfortLink controls. All ERV configuration, setup and troubleshooting is done via ComfortLink controls. Modulating OA ventilation damper New Outside Air Unit points table New control functions for accessory devices: Exhaust fan building pressure control Open protocol integration ti solutions available OAU table applies to EnergyX modulating CFM units only; OAU System Run State OAU Operating Mode UPC Software Version OA Unit Software Version OAU 2-position Exhaust Damper * OAU Wheel Speed OAU Leaving Air Temp OAU Exhaust Air Temp Minimum Outside Air CFM Min DCV Outside Air CFM OA Ventilation Damper Position Actual Outside Air CFM Command Outside Air CFM Power Exhaust CFM Offset OAU Exhaust Fan Speed Actual Exhaust Air CFM Command Exhaust Air CFM Building Pressure Set-point * Building Pressure * OA Tempering Lockout Temp * OA Tempering SAT Set-point * OAU Tempering Heater * * Optional device 11

12 EnergyX System Ease Of Selection Carrier s RTUBuilder FIOP selection: EnergyX RTU airflow Building return/exhaust airflow and design conditions ERV ventilation airflow and design conditions 12

13 EnergyX System Ease Of Selection (cont) Combined Efficiency (CEF) Combined Heating Capacity Combined Cooling Capacity One Integrated Location 13

14 EnergyX System Field Installed Accessories Horizontal roofcurb adaptors used when horizontal supply and/or return is required Motor status indicator accessory monitors wheel, supply & exhaust motors and provides indication if not operating Filter status indicator accessory monitors static pressure across supply & exhaust filters and provides indication when filters become clogged 14

15 EnergyX System 15

16 ENERGYX ENERGY RECOVERY Airxchange Wheel Assembly Airxchange Energy Recovery Cassette: UL certified, AHRI listed, silica gel enthalpy desiccant, wheels > 25 diameter are segmented for easy cleaning, washable with detergent and water, 5 year std warranty Operation: Energy recovery wheels rotate between the incoming outdoor airstream and the building exhaust airstream. As the wheel rotates, it transfers heat and moisture from one airstream to the other. Result = outdoor air is pre-conditioned, significantly reducing the capacity and energy needed from the mechanical HVAC system. TYPICAL SUMMER CONDITIONS TYPICAL WINTER CONDITIONS 16

17 Benefits Of EnergyX System Why Energy Recovery 1. Code requirements: ASHRAE : Energy Recovery is required when design supply air capacity is >5000 CFM & have 70% OA. ASHRAE : Significantly increases the application ranges where Energy Recovery is required. 2. Energy efficiency: System efficiencies as high as 18+ CEF (AHRI Guideline-V) 3. Utility Rebates 4. Expand the application i range of base rooftop unit: i Provide extra cooling, dehumidification & heating capacity OR Downsize base unit by using the ERV to pre-conditioning i the ventilation air OR Allow the base unit to handle more ventilation airflow (and still meet design capacity & Leaving Air Temp requirements) 17

18 ASHRAE CLIMATE ZONES ASHRAE uses climate zones for energy recovery requirements 18

19 ASHRAE Section 6 Addendum e Revises the requirements for energy recovery and extends them to a broader range of applications. Requirement is based on % outdoor air and supply CFM and dis region specific. If outdoor air and supply air meet the requirements, energy recovery is required. CLIMATE ZONE Examples: 7.5 ton unit, 3000 CFM: 60% or more OA 10 ton unit, 4000 CFM: 50% or more OA 15 ton unit, 6000 CFM: 30% or more OA Note: standard used a single value of total airflow >5000 CFM & 70% OA. 19

20 TYPICAL BUILDING REQUIREMENTS Outdoor Air - Ventilation Typical outside air requirements that are MANDATORY Building % OA for a building designed to meet ASHRAE and Primary School 75 ASHRAE Secondary School 69 Exact values will change based on the occupancy and space design. Retail 65 The energy recovery will impact building designs that Strip Mall 62 need ~25% outdoor air or more. Hospital 54 These applications cover ~ 75% of the industry Outpatient Care 50 applications for light commercial rooftop units. Small Office 46 Restaurant 36 Use of energy recovery reduces compliance complexity Fast Food 34 for designing engineers! Large Office 32 Medium Office 27 ASHRAE 189 requires energy recovery on applications with more than ~ 5% outside air. Warehouse 26 Hotel ton unit, 3000 CFM: 60% or more OA Grocery ton unit, 4000 CFM: 50% or more OA Motel ton unit, 6000 CFM: 30% or more OA 20

21 EnergyX System Efficiency Ratings Energy Recovery Ventilators (ERV) use AHRI Guideline-V to provide a total system energy efficiency value: EER = net cooling capacity / total input kw (RTU EER) & (ERV EER) = System EER = Combined Efficiency Factor (CEF) ERV - EER is calculated differently than RTU EER: AHRI Rooftop Unit EER rating specifies static pressure, ambient & evaporator temp values. Does not specify use of Outdoor Air ERV s use outdoor air (pre-conditioned by return air) ERV s use fans & no compressor = highly efficient Reference: 21

22 AHRI GUIDELINE-V Combined Efficiency Factor (CEF) RTU Energy Efficiency Ratio ERV Recovered Energy Efficiency Ratio EER Net conditioning capacity of RTU Total electric power by RTU RER Net conditioning recovered by ERV Total electrical power consumed by ERV EER RER CEF = Combined Efficiency Factor (system EER) Reference: 22

23 EnergyX System CEF Examples ( Ton) * CEF equates to a system EER value In example cities systems experience up to 8.40 efficiency point boost, with an average increase of 4.5 points of efficiency! 23

24 EnergyX System CEF Examples (15 25 Ton) Rooftop Unit RTU AHRI EER ERV Wheel RTU Airflow (CFM) ERV Airflow (CFM) Atlanta Miami Phoenix Montreal Detroit ERV RER 48HC ERC HC ERC HC ERC-4646C HC ERC-4646C CEF ERV RER CEF ERV RER CEF ERV RER CEF ERV RER CEF Atlantat Miamii Phoenix Montreal Detroit Rooftop Unit RTU AHRI EER ERV Wheel RTU Airflow (CFM) ERV Airflow (CFM) ERV RER CEF ERV RER CEF ERV RER CEF ERV RER CEF ERV RER CEF 50HC ERC HC ERC HC ERC-4646C HC ERC-4646C * CEF equates to a system EER value In example cities systems experience up to 6.37 efficiency point boost, with an average increase of 4 points of efficiency! 24

25 EnergyX System Rebate Opportunities Utility Rebates for Energy Recovery Ventilators Electric and Gas Utilities Recognize the Benefits of Energy Recovery Ventilation Many electric and gas utilities offer generous rebate programs in order to encourage the use of energy recovery ventilation (ERV). The reduction in peak load as well as ongoing operating savings combines to help utilities achieve their mandate in encouraging use of energy efficient equipment. ERV qualifies for custom rebate programs that are offered by most utilities. Usually, the local utility representative administers the program and will assist customers with the qualification process. Link to DSIRE website 25

Trends in High Efficiency HVAC Packaged Products May 2012

Trends in High Efficiency HVAC Packaged Products May 2012 Trends in High Efficiency HVAC Packaged Products May 2012 AGENDA Packaged commercial HVAC equipment and application overview Trends in high efficiency commercial packaged products Full load mechanical

More information

Bill McCullough. Director ERV Products. Dallas, TX

Bill McCullough. Director ERV Products. Dallas, TX Bill McCullough Director ERV Products Dallas, TX TOPICS 1. ERV Definition & Benefit 2. Indoor Air Quality 3. Energy Efficiency 4. ERV Technology & Operation 5. Stand-Alone ERVs 6. Compact ERVs What is

More information

Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery with Cooling and Heating Model ERCH Energy Recovery with Cooling and Heating Model ERCH 100% Outdoor Air System Dedicated Outdoor Air System 1,000-10,000 cfm 1.75 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating,

More information

Energy Recovery with Cooling and Heating

Energy Recovery with Cooling and Heating Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model

More information

Energy Recovery Ventilators

Energy Recovery Ventilators Energy Recovery Ventilators Models ERM, MiniVent, ERV and ERVe Untempered Preconditioners September 2016 Energy Recovery Ventilators Greenheck offers a complete line of energy recovery ventilators to reduce

More information

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged

More information

Designing Energy Efficient Outdoor Air Systems

Designing Energy Efficient Outdoor Air Systems Designing Energy Efficient Outdoor Air Systems Joseph Thorndal Applied Products Sales Manager Greenheck, Schofield, Wisconsin 1 Joseph Thorndal BS Industrial Engineering North Dakota State University Work

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer SUBMITTAL Project CLU Swenson Center Date 01/07/2010 Mechanical Contractor West Coast Air Conditioning Mechanical Engineer J & S Consulting Engineers, Inc. Revision Notes RTU-101, 102, 103, 201, 202, 203,

More information

RT-OA TM Rooftop Outdoor-Air (DOAS)

RT-OA TM Rooftop Outdoor-Air (DOAS) RT-OA TM Rooftop Outdoor-Air (DOAS) A/C s & HEAT PUMPS Dedicated Outside-Air System (DOAS) Solutions Office Buildings, Schools, Hospitals, Restaurants, Gyms & Fitness Centers, Hotels, Retail Stores...!

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Adding More Fan Power Can Be a Good Thing

Adding More Fan Power Can Be a Good Thing This article was published in ASHE Journal, May 14. Copyright 14 ASHE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of

More information

Energy Recovery Ventilation

Energy Recovery Ventilation Published on Business Energy Advisor (https://oncor.bizenergyadvisor.com) Home > Energy Recovery Ventilation Energy Recovery Ventilation Proper ventilation is essential for maintaining good indoor-air

More information

MiniCore Ventilator (500, 1000) Series Engineering Guide

MiniCore Ventilator (500, 1000) Series Engineering Guide MiniCore Ventilator (500, 1000) Series Engineering Guide November 2017 V1.0 Johnson Controls, Inc. All rights reserved. TABLE OF CONTENTS Page Functionality and Benefits... 1 Unit Overview... 3 MiniCore

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional 1,000-6,000 cfm 2.0 in. wg External Static Pressure Aluminum Plate Heat Exchanger April 2017 Heat Recovery Ventilators Greenheck

More information

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility Landmark Performance Marked by Flexibility Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models Up to 13.0 SEER, 14.0 IEER and 12.7 EER Performance Marked by Flexibility When it comes to reliable

More information

MAXA-MI$ER Energy recovery solutions

MAXA-MI$ER Energy recovery solutions MAXA-MI$ER Energy recovery solutions Regardless of building type or rating system, today s building must be as energy efficient as possible. The design of an HVAC system is critical to the success of the

More information

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION

More information

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery Steven T. Taylor, PE Principal Taylor Engineering This program is registered with the AIA/CES for continuing professional education.

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Agenda and Objectives

Agenda and Objectives Agenda and Objectives Trane Engineers Newsletter Live Series Rooftop variable-air-volume (VAV) systems are used to provide comfort in a wide range of building types and climates. This ENL discusses HVAC

More information

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE This article was published in ASHRAE Journal, March 20145 Copyright 2015 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission

More information

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)

More information

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

Application Data. Fig. 1 39M Unit with Energy Recovery Section

Application Data. Fig. 1 39M Unit with Energy Recovery Section Aero 39MN03-30 Air Handlers Energy Recovery Section Application Data CONTENTS Page INTRODUCTION.................................1,2 Why Energy Recovery Ventilation?............... 2 AERO 39MN ENERGY RECOVERY

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

AFD Industrial Dehumidifier Series

AFD Industrial Dehumidifier Series Dryomatic HUMIDITY CONTROL A MEMBER OF MARDUK HOLDING COMPANY LLC AFD Industrial Dehumidifier Series DRYOMATIC is a Leader in the Dehumidification Industry with Over 5 Years Experience and Thousands of

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat SINGLE PACKAGE ROOFTOP, GAS HEATING/ELECTRIC COOLING UNIT WITH PURON R (R-410A) REFRIGERANT ONE STAGE COOLING CAPACITY CONTROL: SIZES 08-12 TWO STAGE COOLING CAPACITY CONTROL: SIZES 08, 12 & 14 Submittal

More information

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM D Units Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM INDUSTRY-LEADING HVAC MANUFACTURER Nortek Air Solutions is the largest custom HVAC manufacturer in North America, with a combined total of

More information

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume COMMERCIAL HVAC PACKAGED EQUIPMENT Rooftop Units Level 1: Constant Volume Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application

More information

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series PRODUCT SERIES VPR Series VPRX Series VPRE Series VPRP Series VPRC Series Valent Air Management Products Valent Air Management Systems designs and manufactures reliable, high-outdoor-air ventilators. Our

More information

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes In Humid Climates BY DAVID A. JOHN, P.E., MEMBER ASHRAE; DREW ELSBERRY, MEMBER ASHRAE Designing g a building s HVAC system requires designers

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with NOVATIONt Coil Sizes 08, 12, 14 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED

More information

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: DCC Commercial 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling

More information

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog H3/V3 Series Horizontal and Vertical Indoor Air Handling Units Engineering Catalog Table of Contents AAON H3/V3 Series Features and Options Introduction... 6 H3/V3 Base Model Description... 7 Unit Size...

More information

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron 50VT---C Comfortt 14 SEER Single---Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single Phase 2 --- 5 Nominal Tons (Sizes 24 --- 60) Three Phase 3 --- 5 Nominal Tons (Sizes 36 --- 60) Product

More information

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE RHS Product Specifications ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, 15 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE IEER s up to 11.5 with single speed indoor fan motor and

More information

DIGI-VAV APPLICATIONS

DIGI-VAV APPLICATIONS DIGI-VAV DIGI-VAV APPLICATIONS Digi-VAV: An optimization kit for Variable Air Volume Air Handling Units (VAV AHU) that ensures individual zone indoor air quality (IAQ), and minimizes system energy consumption.

More information

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron 50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron R (R---410A) Refrigerant 15, 17.5, 20, 25, 27.5 Tons --- (Sizes 17, 20, 24, 28, 30) Product Data (Unit shown with economizer and

More information

Variable Refrigeration Flow Systems Overview 10/11/2016

Variable Refrigeration Flow Systems Overview 10/11/2016 Variable Refrigeration Flow Systems Overview 10/11/2016 Executed by Data Power Technology Illinois Aggressively, relentlessly anticipating and exceeding our customer s and client s expectations every day,

More information

50TM COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS 50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form

More information

AFD DEHUMIDIFIER SERIES

AFD DEHUMIDIFIER SERIES The DRYOMATlC AFD Series is a complete factory engineered and fabricated desiccant dehumidification system with performance capabilities as shown on AFD data sheets~ The desiccant dehumidifier is a complete

More information

Vision and Skyline Semi-custom Air Handlers

Vision and Skyline Semi-custom Air Handlers Vision and Skyline Semi-custom Air Handlers Flexible design solutions to match building applications Skyline Outdoor Air Handler 900 to 65,000 cfm Vision Indoor Air Handler 900 to 100,000 cfm Custom solutions

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

100% Outdoor Air Dehumidification Methods

100% Outdoor Air Dehumidification Methods Technical Bulletin 16 100% Outdoor Air ehumidification Methods I NTROUCTION As consulting engineers and end users implement the ASHRAE 6 ventilation code, they are faced with selecting an appropriate method

More information

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs Custom Units to Meet Your Unique Design Needs Engineered for flexibility and performance Contents Horizontal Configuration....1 Horizontal with Standard Economizer Configuration...2 Stacked Configuration...3

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs 2018 LIGHT COMMERCIAL ROOFTOP UNITS Industry-leading efficiency and innovation to meet your needs SM Energence rooftop units Saving Energy with Intelligence The intelligent technology built into Energence

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER DCC Series Submittal Data Form Job Name 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By:

More information

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS SUBMITTAL ***FOR APPROVAL*** TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS Project 66 Orland Square Dr. Landlord Renovations Location Orland Park,

More information

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR INSTALLATION INSTRUCTIONS Models: ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR For Use with Bard 2 Thru 5 Ton "P" Series Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan,

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

THE ULTIMATE ROOFTOP SOLUTION

THE ULTIMATE ROOFTOP SOLUTION Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly

More information

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks Ventilation Heat Recovery PoolPak International Maintaining Your Climate for Indoor Pools and Waterparks Complete Ventilation, Heat Recovery and Dehumidification Packaged System by PoolPak International

More information

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29) 50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29) Product Data (Unit shown with economizer and power

More information

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

Daikin Blueprint: Delivering Hot Water with a Chiller

Daikin Blueprint: Delivering Hot Water with a Chiller Daikin Blueprint: Delivering Hot Water with a Chiller Analyzing the design of heat recovery on air-cooled chillers and the effect it has on building energy consumption By Paul Crisman Daikin Chiller Applications

More information

THE RIGHT SPEC. RIGHT NOW.

THE RIGHT SPEC. RIGHT NOW. THE RIGHT SPEC. RIGHT NOW. 6-12.5 TONS R7DA Gas/Electric Packaged DOAS System MADE FOR THOSE WHO RESPECT THE SPEC. Reznor light commercial packaged rooftops are highly configurable at the factory, so consultant

More information

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS 48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT

More information

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece

More information

General unit Specification Version: August 8, 2013 Model JDMA : Make-up / Ventilation Air Page 1 of 13

General unit Specification Version: August 8, 2013 Model JDMA : Make-up / Ventilation Air Page 1 of 13 Model JDMA : Make-up / Ventilation Air Page 1 of 13 SECTION 15720 Mechanical Specification Packaged Unitary Make-up and Ventilation Air ** Remove all notes shown in red with ** before use/publishing. Part

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

General Unit Specification Version: August 8, 2013 Model JDHA : DX High Outside Air Unit Page 1 of 14

General Unit Specification Version: August 8, 2013 Model JDHA : DX High Outside Air Unit Page 1 of 14 Model JDHA : DX High Outside Air Unit Page 1 of 14 SECTION 15720 Mechanical Specification Packaged DX High Outside Air Unit - JDHA ** Remove all notes shown in red with ** before use/publishing. Part 1

More information

PR SERIES SELECTION AND OPTIMIZATION GUIDE

PR SERIES SELECTION AND OPTIMIZATION GUIDE PR SERIES SELECTION AND OPTIMIZATION GUIDE SOLUTIONS TO FREQUENTLY MISSED SELECTIONS # 1 2 3 4 5 6 7 8 9 10 Position & Length 1-2 3 4 5-6-7 8-9 10 11 12 13 14-15 Supply Product Nominal Model Airflow Type

More information

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee ASHRAE WILL GIVE YOU THE WORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee Complete the Distinguished Lecturer Event Summary Critique CTTC

More information

PERFORMANCE, INNOVATION, RELIABILITY

PERFORMANCE, INNOVATION, RELIABILITY WeatherExpert Series Ultra High Efficient Single Package Rooftop and Single Zone VAV Cooling Only with Optional Electric Heat Sizes 04-06 with Puronr (R- 410A) Refrigerant 3-5NominalTon Product Data Unit

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-007 QWSERV 90-08 QWSERV with Intelligent Defrost For Use With Bard Through 5 Ton QW*S Series Bard Manufacturing Company, Inc. Bryan,

More information

CHAPTER 4. HVAC DELIVERY SYSTEMS

CHAPTER 4. HVAC DELIVERY SYSTEMS CHAPTER 4. HVAC DELIVERY SYSTEMS 4.1 Introduction 4.2 Centralized System versus Individual System 4.3 Heat Transfer Fluids 4.4 CAV versus VAV Systems 4.5 Common Systems for Heating and Cooling 4.6 Economizer

More information

Dedicated Outdoor Air Systems: AHRI 920, ISMRE & ASHRAE 90.1

Dedicated Outdoor Air Systems: AHRI 920, ISMRE & ASHRAE 90.1 Dedicated Outdoor Air Systems: AHRI 920, ISMRE & ASHRAE 90.1 1 Peter Teige, Application Engineering Manager, AHRI Member Technical Training, October 12, 2016 AHRI 920: Establishes Efficiency Metric for

More information

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS 50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York

More information

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER DSC Series Submittal Data Form 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Standard

More information

Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER

Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER The most energy-efficient rooftop unit in the industry* Commercial Packaged Rooftop Units 3- to 24-Ton Models Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER Start an efficiency revolution with the

More information

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons Product Data OMNIZONE 50BRN,BZN006-024 Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems 5 to 20 Nominal Tons The 50BRN,BZN water-cooled and remote air-cooled indoor, self-contained units

More information

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Single Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units FORM 100.50-EG2 (502) TM FlexSys Configured Packaged Rooftop Air Conditioning Units TABLE OF CONTENTS PAGE TOTAL INTEGRATED HVAC SYSTEM... 3 AN INTEGRATED SOLUTION... 4 INTRODUCTION... 6 System Description...

More information

Advanced Product Data

Advanced Product Data 48LC Ultra High Efficiency Gas Heat/Electric Cooling Packaged Rooftop 3to5NominalTons Advanced Product Data C11536 Exceeds Use of the AHRI Certified TM Mark indicates a manufacturer s participation in

More information

GUIDE SPECIFICATIONS - 48HC*D17-28

GUIDE SPECIFICATIONS - 48HC*D17-28 Note about this specification: GUIDE SPECIFICATIONS - 48HC*D17-28 These specifications are written in Masterformat as published by the Construction Specification Institute. Please feel free to copy this

More information

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan Submittal Data Form Job Name DCC Series 3-6 Ton Packaged Air Conditioner 13 SEER / Up to 11.3 EER 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity: 34,600 71,000

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

More information

PACKAGED HVAC EQUIPMENT CATALOG

PACKAGED HVAC EQUIPMENT CATALOG PACKAGED HVAC EQUIPMENT CATALOG COMMERCIAL/INDUSTRIAL HVAC CAPACITIES 5-70 Tons Cooling (Fixed and Modulating Capacity) Dehumidification 1,000-13,000 CFM 100-1,600 MBH (Gas Heating) 8:1 or 16:1 Gas Heating

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR KITCHENS HOTEL CORRIDORS LABORATORIES CONFERENCE CENTERS SCHOOLS PAINT BOOTHS MALLS/SHOPPING CENTERS DOAS UNITS Capacities 5-30 Tons 50-800 MBH 30-120 kw 650-9,000

More information

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS. PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130

More information

Product Data. Features/Benefits

Product Data. Features/Benefits Product Data WEATHERMASTER 48/50P2,P3,P4,P5030-100 Single-Package Gas Heating/Electric Cooling Rooftop Units and Electric Cooling Rooftop Units with Optional Electric Heat with COMFORTLINK Controls and

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

b.) Technical Information:

b.) Technical Information: Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,

More information

Multi-Path RTU-TYPE 2

Multi-Path RTU-TYPE 2 ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 2 (RTU1) CESMPU025RHVAV2 Date: February 17, 201 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV2 Unit features include: 25 Ton MultiPath

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information