1 product Information on oil, gas and dual fuel burners Industrial burners Industrial burners sizes to flexible and reliable
2 Weishaupt Industrial Burners: Flexible and reliable For more than years, Weishaupt industrial burners have set global standards in terms of reliability, energy efficiency, noise levels and ease of use. With firing rate between, and, MBH, the spectrum of application possibilities covers from heating and steam boilers to air heaters and modern high efficiency boilers. With its wide of industrial burners, which can be used with almost any gaseous or liquid fuel, Weishaupt has the right burner for virtually any job. Digital combustion management, included as standard with industrial burners, contributes not only to the economical use of oil and gas, but also simplifies the operation and servicing of the burner. Moreover, the integration into various monitoring and control systems and into complete building management systems is made possible. The clear layout of the burners with their easily accessible components enables quick and reliable service and therefore also faster commissioning. Selected materials combined with experience gained over decades in a modern research and development centre and an extensive service network guarantee Weishaupt proverbial reliability.
3
4 Burner motor Air pressure switch Burner housing can be hinged open to the left or to the right Mixing head Flame sensor Digital combustion manager with display and operating unit ABE Stepping motor for sliding sleeve Stepping motor for air damper control Fan wheel
5 Index of contents Oil burners version Standard Burner selection Scope of delivery / Accessories Technical data multiflam oil burners version LN Burner selection Scope of delivery / Accessories / Technical data Gas burners NR Burner selection Scope of delivery / Accessories Technical data Gas burners LN Burner selection Scope of delivery / Accessories/ Technical data multiflam gas burners version LN Burner selection Scope of delivery / Accessories Technical data multiflam dual fuel burners version LN Burner selection Scope of delivery / Accessories Technical data Gas burners LN Burner selection Scope of delivery / Accessories Technical data Dimensions Fuel systems Dual fuel burners NR Burner selection Scope of delivery / Accessories Technical data Pump and preheater station Dual fuel burners LN Burner selection Scope of delivery / Accessories Technical data
6 Weishaupt industrial burners sizes to High capacity and flexible application Weishaupt industrial burners have been especially designed for industrial applications. The monobloc burners are noteworthy for their large capacity and operational s and numerous technical details: Flexible application The burners can be used on heat exchangers such as hot water boilers, steam boilers, air heaters and for certain process applications. As the burners are capable of overcoming high combustion chamber resistances, they are primarily used on high efficiency boilers. Digital combustion management Digital combustion management ensures simple and safe operation of combustion application. All important functions, such as fuel and air supply or flame monitoring are controlled with digital precision. Operational functions are optimized, economy is maximized and emissions are minimized. The integral ModBus interface allows communication with building automization/ management system. Energy saving with speed control and O trim Electrical consumption is definitely a cost factor for large combustion application. Speed control uses frequency drive to match fan speed to the actual air requirement, allowing for significant savings of electricity, particularly at low fire. With O trim the flue gases are continuously monitored and controlled to ensure the best possible degree of combustion efficiency and thus lower fuel consumption and increased reliability. Applicable fuels Light oil # viscosity up to cst ( mm /s) at F ( C) to ASTM D Medium # to heavy fuel # oil viscosity up to cst ( mm /s at F ( C) to ASTM D Natural Gas Propane Permissible ambient conditions: Ambient temperature - to + C ( to F) - to + C ( to F) Air humidity: max. % relative humidity, no condensation Suitable only for indoor operation For installation in unheated rooms under some circumstances special solutions are required (contact Weishaupt) Any discrepancy from the above described applications requires written confirmation from Weishaupt Corporation. The maintenance interval could be shortened according to conditions where the burners are installed. Approvals The burners are in compliance with most North American and European applicable standards. Outstanding service Weishaupt maintains an extensive global sales and service network. Customer service is available every day around the clock. In-house training by Weishaupt ensures the high standard of their service engineers. The most important advantages: Large capacity and application Stable fan characteristics Good combustion behaviour Burner housing can be hinged open Easy installation, commissioning and service Increased safety provided by nozzle head shut off device with dedicated nozzle shut off solenoid Nozzle circulation and precise oil temperature regulation on heavy fuel oil burners Compliance with current emission standards worldwide High turndown ratio (RL, RGL)
7 Characteristics of the different variations Version Standard Oil, gas and dual fuel burners for installations without specific NO x requirements. Suitable for Natural Gas, Propane, # - # oil, as well as special gases and special oils on request. Version NR Gas and dual fuel burners with advanced, standard mixing head for applications where there is NO x requirements on gas side. NR means: lower NO x emission on gas side compared to the standard version. Oil side as standard version. Suitable for Natural Gas, Propane, # - # oil. Version LN LowNO x gas and dual fuel burners with patented multiflam mixing head for installations with more stringent low NO x requirements. Low NO x values are achieved by fuel distribution method. Suitable for Natural Gas, Propane and # oil. Version LN LowNO x gas and dual fuel burners with special mixing head for applications, where there are requirements for lower NO x emission on gas and oil side. LN means: lower NO x values compared to version NR. Suitable for Natural Gas, Propane, # oil. Version LN LowNO x gas burners with special mixing head for installations where there is requirement for lower NO x emission on gas operation. Lower NO x value compared to vers. LN. Suitable for Natural Gas and Propane.
8
9 Oil burners
10 Burner selection Oil burners size, version Standard Burner model MSZ/-A Combustion head M/ - k x Capacity in MBH,, Capacity in GPH#. Burner model RMS/-A Combustion head M/ - k x Capacity in MBH,, Capacity in GPH# MBH,,,,,,,,, - MBH,,,,,,,,, GPH #.... GPH #.... Fuels # oil Burner model vers. Order No. MSZ/-A RMS/-A ZM The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) an installation altitude of, ft ( m) above sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
11 Burner selection Oil burners size, version Standard Burner model MSZ/-B MSZ/-B Combustion head M/ - x M/ - x Capacity in MBH,,,, Capacity in GPH#.. Burner model RMS/-B Combustion head M/ - k x Capacity in MBH,, Capacity in GPH# MBH,,,,,,,,,,,, - MBH,,,,,,,,,,,, GPH # GPH # Burner model RMS/-A Combustion head M/ - k x Capacity in MBH,, Capacity in GPH#.. Burner model Vers. Order No. MSZ/-B RMS/-B ZM RMS/-A ZM - - MBH,,,,,,,,,,,,,, GPH # Fuels # oil The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) an installation altitude of, ft ( m) above sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
12 Burner selection Oil burners size, version Standard Burner model LT/-A Combustion head M/ - x Capacity in MBH,, Capacity in GPH# Burner model RL/-B RMS/-B Combustion head M/ - x M/ - x Capacity in MBH,,,, Capacity in GPH# GPH# MBH,,,,,,,,, - MBH,,,,,,,,,,,,,, GPH GPH # GPH # - Burner model RL/-A RMS/-A Combustion head M/ - x M/ - x Capacity in MBH,,,, Capacity in GPH# GPH#. Burner model Vers. Order No. LT/-A - RL/-B ZM RMS/-B ZM RL/-A ZM RMS/-A ZM The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. - MBH,,,,,,,,,,,, GPH # GPH # Fuel oils # oil # oil The capacity graphs are based on air temperature of F ( C) an installation altitude of, ft ( m) above sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
13 Burner selection Oil burners size and, version Standard Burner model RL/-A RMS/-A Combustion head M/-- M/-- Capacity in MBH,,,, Capacity in GPH# GPH# Burner model RL/-A RMS/-A Combustion head M/a-- M/a-- Capacity in MBH,,,, Capacity in GPH# GPH# MBH,,,,,,,,,,,,, - MBH,,,,,,,,,,,,,, GPH # GPH # GPH # GPH # - Burner model RL/-A RMS/-A Combustion head M/a-- M/a-- Capacity in MBH,,,, Capacity in GPH# GPH# Burner model Vers. Order No. RL/-A ZM RMS/-A ZM RL/-A ZM RMS/-A ZM RL/-A ZM RMS/-A ZM The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. - MBH,,,,,,,,,,,,, GPH # GPH # Fuels # oil # oil The capacity graphs are based on air temperature of F ( C) an installation altitude of, ft ( m) above sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
14 Scope of delivery/accessories Oil burners size to, version Standard Scope of delivery MS MS RMS RMS RMS RMS RMS L RL RL RL Burner housing, hinge flange, housing cover, Weishaupt burner motor, air intake housing fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes nozzle assembly with oil nozzle/s, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Air pressure switch Oil pressure switch in return Oil pressure switch in supply Adjustable regulating sleeve in mixing head Sliding sleeve in mixing head Oil pump, fitted Oil preheater, fitted Oil hoses oil solenoid valves, safety shut off valve, three stage nozzle head without shut off device normally closed solenoid valve in supply and return, nozzle head with shut off device (nozzle solenoid on RL and RMS, hydraulically controlled ball valve on MS) normally closed solenoid valve in supply and return, bypass solenoid valve, nozzle head with shut off device (nozzle solenoid) Downward firing version Heating cartridges Accessories Intake flange for connection of air duct Stainless steel oil hoses, heated Magnetic coupling Combustion head extension Media preheater with fittings Speed control O trim W-FM loosed for installation in remote panel Scope of delivery Accessories Additional accessories on request.
15 Technical data Oil burners size and, version Standard Technical data MSZ/-A RMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.) FLA at V A.. Speed ( Hz) rpm,, Fan wheel Color / ø red / x red / x Combustion manager Model LAL. W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model / SQM Fuel Model SQM Mixing head Model SQM Pump fitted Model E TA Oil preheater Model EVD EVD Oil throughput GPH and (kg/h) () () Heat rating kw.. Oil solenoid valves V / W Model K V / W Model K V / (supply) W Model H H V / (return) W Model G G Oil pressure switches bar (return fuel oil EL - bar) Model bar (return fuel oil S - bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () (on MS, RMS and RGMS, high pressure metal hoses) / () / () Burner weight approx. lbs (kg) () () Technical data MSZ/-B RMS/-B RMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.). (.) FLA at V A Speed ( Hz) rpm,,, Fan wheel Color / ø red / x red / x red / x Combustion manager Model LAL. W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Pump fitted Model E TA TA Oil preheater Model EVD EVD ) ) EVD Oil throughput in GPH and (kg/h) () () () Heat rating kw... Oil solenoid valves V / W Model K V / (safety v.) W Model V / W Model K V / (supply) W Model H H H V / (return) W Model G G G Oil pressure switches bar (return # oil - bar) Model bar (return # oil - bar) Model DSA F DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () / () (on MS, RMS and RGMS, high pressure metal hoses) / () / () / () Burner weight approx. lbs (kg) () () () ) Burners above GPH ( kg/h): Oil preheater WEV. in lieu of EVD, Refer to Accessories ) Burners above. GPH ( kg/h): Oil preheater WEV in lieu of WEV., Refer to Accessories
16 Technical data Oil burners size, version Standard Technical data LT/-A RL/-B RL/-A Burner motor ~ V - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw) (). () () FLA at V A Speed ( Hz) rpm,,, Fan wheel Colour / ø red / x. red / x. red / x. Combustion manager Model W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Pump, fitted Model TAC TAC TC Oil preheater Model Oil throughput in GPH and (kg/h) Heat rating kw Oil solenoid valve V / W Model K ( off) V / (safety v.) W Model K V / (supply) W Model H H V / (return) W Model G G Oil pressure switches bar (return # oil - bar) Model DSA F DSA F bar (return # oil - bar) Model Oil hoses DN, length in inch and (mm) / () / () / () Burner weight approx. lbs (kg) () () () Technical data RMS/-B RMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour / ø red / x. red / x. Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Pump, fitted Model TAC TC Oil preheater Model WEV./ ) WEV/ Oil throughput in GPH and (kg/h). (). () Heat rating kw.. Oil solenoid valve V / (supply) W Model H H V / (return) W Model G G Oil pressure switches bar (return # oil - bar) Model bar (return # oil - bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () (on MS, RMS and RGMS, high pressure metal hoses) / () / () Burner weight approx. lbs (kg) () () ) Burners above. GPH ( kg/h): Oil preheater WEV in lieu of WEV., Refer to Accessories
17 Technical data Oil burners size and, version Standard Technical data RL/-A RMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw) () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour / ø red / x red / x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Pump fitted Model TC Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G V / (bypass) W Model H Oil pressure switches bar (supply- bar) Model DSA F bar (return # oil- bar) Model DSA F bar (return # oil- bar) Model DSA F Oil hoses DN, length in inch and (mm) / () / () (on RMS and RGMS, high pressure metal hoses) / () Burner weight approx. lbs (kg) () () ) Technical data RL/-A RL/-A RMS/-A RMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw). (). (). (). () FLA at V A Speed ( Hz) rpm,,,, Fan wheel Colour / ø yellow / x green / x yellow / x green / x Combustion manager model W-FM W-FM W-FM W-FM Ignition unit model W-ZG W-ZG W-ZG W-ZG Stepping motor Air model SQM SQM SQM SQM Fuel model SQM SQM SQM SQM Mixing head model SQM SQM SQM SQM Pump fitted model TC (up to GPH/ kg/h) model TC (from GPH/ kg/h) Oil solenoid valves V / (supply) W Model H H H H V / (return) W Model G G G G V / (bypass) W Model H H Oil pressure switch bar (supply- bar) Model DSA F DSA F bar (return # oil- bar) Model DSA F DSA F bar (return # oil- bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () / () / () (on RMS and RGMS, high pressure metal hoses) / () / () Burner weight approx. lbs (kg) () () () ) () ) ) Weight without pump and preheater station
18
19 Gas burners
20 Burner selection Gas burners size to, version NR Burner model G/-B, vers. ZM-NR Combustion head G/-NR x Capacity in MBH Nat Gas,, Propane,, Burner model G/-A, vers. ZM-NR Combustion head G/-NR x Capacity in MBH Nat Gas,, Propane,, - - -,,,,,,,,,,,,,, -,,,,,,,,,,, Burner model G/-A, vers. ZM-NR Combustion head G/-NR x Capacity in MBH Nat Gas,, Propane,, Burner model G/-B, vers. ZM-NR Combustion head G/-NR x Capacity in MBH Nat Gas,, Propane,, - - -,,,,,,,,,,, -,,,,,,,,,,,,, Fuels Nat gas Propane Burner model Vers. Order No. G/-B ZM-NR G/-A ZM-NR G/-A ZM-NR G/-B ZM-NR The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
21 Burner selection Gas burners size, version NR Burner model G/-A, vers. ZM-NR Combustion head G/-NR x Capacity in MBH Nat Gas,, Propane,, Burner model G/-A, vers. ZM-NR Combustion head G/-NR x Capacity in MBH Nat Gas,, Propane,, - - -,,,,,,,,,,,,,, -,,,,,,,,,,,,,, Fuels Nat gas Propane Burner model Vers. Order No. G/-A ZM-NR G/-A ZM-NR The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
22 Scope of delivery/accessories Gas burners size to, version NR Scope of delivery G G G Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrode, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two gas safety shut off valves Gas butterfly valve Ignition pilot Air pressure switch Gas pressure switches Servomotor driven sliding sleeve in mixing head Stepping motor for Gas /Air ratio control with W-FM Stepping motor for air damper Stepping motor for gas butterfly valve Stepping motor for sliding sleeve Accessories Downward firing burner Intake flange for the connection of an air duct Solenoid valve for air pressure switch test for cont. run fan or post-purge Combustion head extension Speed control O trim W-FM loosed for installation in remote control panel Scope of delivery Accessories Additional accessories on request.
23 Technical data Gas burners size to, version NR Technical data G/-B G/-A G/-A Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw). () () () FLA at V A Speed ( Hz) rpm,,, Fan wheel Colour red red red ø x. x. x Combustion manager Model W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Mixing head Model SQM SQM SQM Fuel Model SQM SQM SQM Burner weight approx. lbs (kg) () () () Technical data G/-B G/-A G/-A Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw) (.). (). () FLA at V A. (at V) Speed (/ Hz) rpm,, ( Hz) Fan wheel Colour green green blue ø x x x Combustion manager Model W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Mixing head Model SQM SQM SQM Fuel Model SQM SQM SQM Burner weight approx. lbs (kg) () () () * Operation at Hz only in conjunction with frequency drive.
24 Burner selection Gas burners size to, version LN Burner model G/-B, vers. ZM-LN Combustion head G/-LN x Capacity in MBH Nat Gas,, Propane,, Burner model G/-B, vers. ZM-LN Combustion head G/-LN x Capacity in MBH Nat Gas,, Propane,, - -,,,,,,,,, - Burner model Combustion head Capacity in MBH Nat Gas,, Propane,, G/-A, vers. ZM-LN G/-LN x,,,,, - -,,,,,,, -,, Burner model G/-A, vers. ZM-LN Combustion head G/-LN x Capacity in MBH Nat Gas,, Propane,,,,,, -,,,,,,,,, -,,,,,,,,,,,, Fuels Nat gas Propane Burner model Vers. Order No. G/-B ZM-LN G/-A ZM-LN G/-B ZM-LN G/-A ZM-LN The capacity graphs are based on air temperature of F ( C) an installation altitude at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration in case of installation altitude above ft. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
25 Scope of delivery/accessories/ Technical data Gas burners size and, version LN Scope of delivery G G Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrode, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two gas safety shut off valves Gas butterfly valve Ignition pilot Air pressure switch Gas pressure switches Adjustable flame tube in mixing head Stepping motor for Gas/Air ratio control with W-FM Stepping motor for air damper Stepping motor for gas butterfly valve Accessories Downward firing burner Intake flange for the connection of an air duct Solenoid valve for air pressure switch test for cont. run fan or post-purge Combustion head extension Speed control O trim W-FM loosed for installation in remote control panel Scope of delivery Accessories Additional accessories on request. Technical data G/-B G/-A G/-B G/-A Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw). () () (.). () FLA at V A. Speed ( Hz) rpm,,,, Fan wheel Colour red red green green ø x. x. x x Combustion manager Model W-FM W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM SQM Fuel Model SQM SQM SQM SQM Burner weight approx. lbs (kg) () () () ()
26 Burner selection Gas burners size, version LN Burner model G/-B, vers. ZM-LN Combustion head G/-a x Capacity in MBH Nat Gas,, Burner model G/-A, vers. ZM-LN Combustion head G/-a x Capacity in MBH Nat Gas,, - - -,,,,,,,,,,,, -,,,,,,,,, Fuels capacity with combustion head open close Nat gas Burner model Vers. Order No. G/-B ZM-LN G/-A ZM-LN The capacity graphs are based on air temperature of F ( C) an installation altitude at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration in case of installation altitude above ft. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
27 Burner selection Gas burners size and, version LN Burner model G/-A, vers. ZM-LN Combustion head G/-a x Capacity in MBH Nat Gas,, Burner model G/-B, vers. ZM-LN Combustion head G/-a x Capacity in MBH Nat Gas,, - - -,,,,,,,,,,, -,,,,,,,,,,,,, Burner model G/-A, vers. ZM-LN Combustion head G/-a x Capacity in MBH Nat Gas,, - -,,,,,,,,,,,, Fuels capacity with combustion head open close Nat gas Burner model Vers. Order No. G/-A ZM-LN G/-B ZM-LN G/-A ZM-LN The capacity graphs are based on air temperature of F ( C) an installation altitude at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration in case of installation altitude above ft. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
28 Scope of delivery/accessories Gas burners size to, version LN Scope of delivery G G G Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two safety gas shut off valves Gas butterfly valve Air pressure switch Gas pressure switches Adjustable flame tube in mixing head Stepping motor for Gas /Air ratio control with W-FM Stepping motor for air damper Stepping motor for gas butterfly valve Accessories Downward firing burner Intake flange for the connection of an air duct Combustion head extension Speed control O trim W-FM loosed for installation in remote panel Scope of delivery Accessories Additional accessories on request.
29 Technical data Gas burners size to, version LN Technical data G/-B G/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour red red ø x. x. Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Burner weight approx. lbs (kg) () () Technical data G/-A G/-B G/-A Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw) (). (.). () FLA at V A Speed ( Hz) rpm,,, Fan wheel Colour red green green ø x x x Combustion manager Model W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Fuel Model SQM SQM SQM Burner weight approx. lbs (kg) () () ()
30
31 Dual fuel burners
32 Burner selection Dual fuel burners size, version NR Burner model RGL/-A, RGMS/-A, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, GPH # oil. GPH # oil Fuels # oil # oil Nat gas Propane - The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. -,,,,,,,, GPH # GPH #,,,,,,, Burner model Vers. Order No. RGL/-A ZM-NR RGMS/-A ZM-NR Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
33 Burner selection Dual fuel burners size, version NR Burner model RGL/-B, RGMS/-B, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, GPH # oil. GPH # oil. Burner model RGL/-A, RGMS/-A, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, GPH # oil. GPH # oil ,,,,,,,,,, -,,,,,,,,,,,,, GPH # GPH # GPH # GPH # Fuels # oil # oil Nat gas Propane Burner model Vers. Order No. RGL/-B ZM-NR RGMS/-B ZM-NR RGL/-A ZM-NR RGMS/-A ZM-NR The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
34 Burner selection Dual fuel burners size, version NR Burner model RGL/-B, RGMS/-B, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, GPH # oil. GPH # oil Burner model RGL/-A, RGMS/-A, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH NG,,,, MBH Propane,,,, GPH # oil.. GPH # oil ,,,,,,,,,,,,,, -,,,,,,,,,,, GPH # GPH # GPH # GPH # Fuels # oil # oil Nat gas Propane Burner model Vers. Order No. RGL/-B ZM-NR RGMS/-B ZM-NR RGL/-A ZM-NR RGMS/-A ZM-NR The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
35 Burner selection Dual fuel burners size and, version NR Burner model RGL/-A, RGMS/-A, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, GPH # oil. GPH # oil. Burner model RGL/-B, RGMS/-B, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, GPH # oil GPH # oil ,,,,,,,,,,, -,,,,,,,,,,,,, GPH # GPH # GPH # GPH # Fuels # oil # oil Nat gas Propane Burner model Vers. Order No. RGL/-A ZM-NR RGMS/-A ZM-NR RGL/-B ZM-NR RGMS/-B ZM-NR The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
36 Burner selection Dual fuel burners size, version NR Burner model RGL/-A, RGMS/-A, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH Gas,,,, MBH Propane,,,, GPH # oil.. GPH # oil. Burner model RGL/-A, RGMS/-A, vers. ZM-NR vers. ZM-NR Combustion head G/-NR x G/-NR x Capacity in MBH NG,,,, MBH Propane,,,, GPH # oil.. GPH # oil - - -,,,,,,,,,,,,,, -,,,,,,,,,,,,,, GPH # GPH # GPH # GPH # Fuels # oil # oil Nat gas Propane Burner model Vers. Order No. RGL/-A ZM-NR RGMS/-A ZM-NR RGL/-A ZM-NR RGMS/-A ZM-NR The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal and # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation altitude of, ft ( m). A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
37 Scope of delivery/accessories Dual fuel burners size to, version NR Scope of delivery RGMS RGMS RGMS RGL RGL RGL Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, nozzle assembly with oil nozzle/s, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two safety gas shut off valves Gas butterfly valve Ignition pilot Air pressure switch Oil pressure switch in return Gas pressure switches Servomotor driven sliding sleeve in mixing head Stepping motor for Gas /Air ratio control with W-FM Stepping motor for air damper Stepping motor for gas butterfly valve Stepping motor for regulating/sliding sleeve Oil pump, fitted Oil preheater, fitted Oil hoses Two oil solenoid valves in supply and return solenoid valve in supply and in return, nozzle head with shut off device (nozzle solenoid) Magnetic coupling Accessories Downward firing burner Intake flange for the connection of an air duct Solenoid valve for air pressure switch test for cont. run fan or post-purge Combustion head extension Speed control O trim W-FM loose to fit into control panel Separate pump station Separate preheater station (electric or media) Scope of delivery Accessories Additional accessories on request.
38 Scope of delivery/accessories Dual fuel burners size and, version NR Scope of delivery RGMS RGMS RGL RGL Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, nozzle assembly with oil nozzle/s, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two safety gas shut off valves Gas butterfly valve Ignition pilot Air pressure switch Oil pressure switch in return Gas pressure switches Servomotor driven sliding sleeve in mixing head Stepping motor for Gas /Air ratio control with W-FM Stepping motor for air damper Stepping motor for gas butterfly valve Stepping motor for regulating/sliding sleeve Oil pump, fitted Oil hoses solenoid valve in supply and in return, nozzle head with shut off device (nozzle solenoid) Magnetic coupling Accessories Downward firing burner Intake flange for the connection of an air duct Solenoid valve for air pressure switch test for cont. run fan or post-purge Combustion head extension Speed control O trim W-FM loose to fit into control panel Separate pump station Separate preheater station (electric or media) Scope of delivery Accessories Additional accessories on request.
39 Technical data Dual fuel burners size and, version NR Technical data RGL/-A RGMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.) FLA at V A.. Speed ( Hz) rpm,, Fan wheel Colour / ø red / x red / x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TA TA Oil preheater Model EVD Oil throughput GPH (kg/h) () Heat rating kw. Oil solenoid valves V / (supply) W Model K V / (return) W Model K V / (supply) W Model H V / (supply) W Model G Oil pressure switches bar (return # oil - bar) Model DSA F bar (return # oil - bar) Model DSA F Oil hoses DN, length in inch (mm) / () (on RGMS, high pressure metal hoses) DN, lenght in inch (mm) / () Burner weight approx. lbs (kg) () () Technical data RGL/-B RGMS/-B Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.) FLA at V A Speed ( Hz) rpm,, Fan wheel Colour / ø red / x red / x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TA TA Oil preheater Model EVD Oil throughput GPH (kg/h) () Heat rating kw. Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G Oil pressure switches bar (return fuel oil EL - bar) Model DSA F bar (return fuel oil S - bar) Model DSA F Oil hoses DN, length in inch (mm) / () (on RGMS, high pressure metal hoses) DN, length in inch (mm) / () Burner weight approx. lbs (kg) () ()
40 Technical data Dual fuel burners size and, version NR Technical data RGL/-A RGMS/-A Burner motor ~ - V (/) Model W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.) FLA at V A Speed ( Hz) rpm,, Fan wheel Colour / ø red / x red / x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TA TA Oil preheater Model EVD Oil throughput GPH (kg/h) () Heat rating kw. Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G Oil pressure switches bar (return fuel oil EL - bar) Model DSA F bar (return fuel oil S - bar) Model DSA F Oil hoses DN, length in inch (mm) / () (on RGMS, high pressure metal hoses) DN, length in inch (mm) / () Burner weight approx. lbs (kg) () () Technical data RGL/-B RGL/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour red red ø x. x. Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TAC TC Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G Oil pressure switch bar (return # oil - bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () Burner weight approx. lbs (kg) () ()
41 Technical data Dual fuel burners size and, version NR Technical data RGMS/-B RGMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour red red ø x. x. Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Oil preheater Model WEV./ ) WEV/ Oil throughput GPH (kg/h). (). () Heat rating kw.. Pump, fitted Model TAC TC Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G Oil pressure switch bar (return # oil) Model DSA F DSA F Oil hoses DN/length / () / () Burner weight approx. lbs (kg) () () ) Burners above. GPH ( kg/h): Oil preheater WEV in lieu of WEV. (refer to Accessories) Technical data RGL/-A RGMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw) () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour red red ø x x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TC Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G V / (bypass) W Model H Oil pressure switches bar (supply - bar) Model DSA F bar (return # oil - bar) Model DSA F bar (return # oil - bar) Model DSA F Oil hoses DN, length in inch and (mm) / () (on RGMS, high pressure metal hoses) DN, length in inch and (mm) / () Burner weight approx. lbs (kg) () () ) ) Weight without pump and preheater stations
42 Technical data Dual fuel burners size, version NR Technical data RGL/-B RGL/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw) (.). () FLA at V A. Speed ( Hz) rpm,, Fan wheel Colour green green ø x x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TC (up to GPH/ kg/h) Model TC (from GPH/ kg/h) Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G V / (bypass) W Model Oil pressure switch bar (supply - bar) Model bar (return # oil - bar) Model DSA F DSA F bar (return # oil - bar) Model Oil hoses DN, length in inch and (mm) / / (on RGMS, high pressure metal hoses) DN, length in inch and (mm) DN, length in inch and (mm) Burner weight approx. lbs (kg) () () Technical data RGMS/-B RGMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw) (.). () FLA at V A. Speed ( Hz) rpm,, Fan wheel Colour green green ø x x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model Model Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G V / (bypass) W Model H H Oil pressure switch bar (supply - bar) Model DSA F DSA F bar (return # oil - bar) Model bar (return # oil - bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) (on RGMS, high pressure metal hoses) DN, length in inch and (mm) / / DN, length in inch and (mm) / / Burner weight approx. lbs (kg) () ) () )
43 Technical data Dual fuel burners size, version NR Technical data RGL/-A RGMS/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). (). () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour blue blue ø x x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Mixing head Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TC Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G V / (bypass) W Model H Oil pressure switches bar (supply - bar) Model DSA F bar (return fuel oil EL - bar) Model DSA F bar (return fuel oil S - bar) Model DSA F Oil hoses DN, length in inch and (mm) / () (on RGMS, high pressure metal hoses) DN, length in inch and (mm) / () DN, length in inch and (mm) / () Burner weight approx. kg () () ) ) Weight without pump and preheater stations * Operation with Hz frequency converter only.
44 Burner selection Dual fuel burners size, version LN Burner model RGL/-B, vers. ZM-LN Combustion head G/-LN xk Capacity in MBH NG,, MBH Propane,, GPH # oil.. Burner model RGL/-A, vers. ZM-LN Combustion head G/-LN x Capacity in MBH NG,, MBH Propane,, GPH # oil ,,,,,,,,,,,,,, -,,,,,,,,, GPH GPH Fuels # oil Nat gas Propane Burner model Vers. Order No. RGL/-B ZM-LN RGL/-A ZM-LN The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
45 Burner selection Dual fuel burners size, version LN Burner model RGL/-B, vers. ZM-LN Combustion head G/-LN x Capacity in MBH NG,, MBH Propane,, GPH # oil. Burner model RGL/-A, vers. ZM-LN Combustion head G/-LN x Capacity in MBH NG,, MBH Propane,, GPH # oil ,,,,,,,,,,,,, -,,,,,,,,,,,, GPH GPH Fuels # oil Nat gas Propane Burner model Vers. Order No. RGL/-B ZM-LN RGL/-A ZM-LN The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
46 Scope of delivery/accessories Dual fuel burners size and, version LN Scope of delivery RGL RGL Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrode, nozzle assembly with oil nozzle/s, combustion manager with operating unit, flame sensor stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two safety gas valves Gas butterfly valve Ignition pilot Air pressure switch Oil pressure switch in return Gas pressure switches Adjustable regulating sleeve in mixing head Adjustable flame tube in mixing head Stepping motor for Gas/Air ratio control with W-FM Stepping motor for air regulator Stepping motor for gas butterfly valve Stepping motor for oil regulator Oil pump, fitted Oil hoses oil solenoid valves, safety valve, two stage nozzle head with shut off device (nozzle solenoid) Magnetic coupling Accessories Downward firing burner Intake flange for the connection of an air duct Solenoid valve for air pressure switch test for cont. run fan or post-purge Combustion head extension Speed control O trim W-FM loose to fit into control panel Scope of delivery Accessories Additional accessories on request.
47 Technical data Dual fuel burners size and, version LN Technical data RGL/-B RGL/-A Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour red red ø x. x. Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TAC TC Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G Oil pressure switch bar (return - bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () Burner weight approx. lbs (kg) () () Technical data RGL/-B RGL/-A Burner motor ~V ) Model W-D/-/K W-D/-/K Motor rating HP (kw) (.). () FLA at V A. Speed ( Hz) rpm,, Fan wheel Colour green green ø x x Combustion manager Model W-FM W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Pump, fitted Model TC (up to GPH/ kg/h) TC (from GPH/ kg/h) Oil solenoid valves V / (supply) W Model H H V / (return) W Model G G Oil pressure switch bar (supply - bar) Model bar (return - bar) Model DSA F DSA F Oil hoses DN, length in inch and (mm) / / Burner weight approx. lbs (kg) () ()
48
49 multiflam Burners
50 multiflam principle: emission reduction as standard ppm ppm NO x The multiflam flame shows efficient combustion In, Weishaupt made history with the introduction of multiflam technology into the market. Unprecedented low emission values stunned the industry. With the patented mixing head, Weishaupt was able to reduce the Nitrous Oxide emissions (NO x ) for medium and large burners to values normally only seen with compact burners. Weishaupt has set the standards with values below ppm for # oil and ppm for natural gas, depending on the relevant combustion chamber geometry. CO NO x Gas Example values for hot water plant depend on the combustion chamber CO # Oil Secondary nozzle Secondary nozzle The multiflam burners therefore comply with the most stringent regulations worldwide and are leaders among industrial burners particularly in countries with strict environmental regulations. Secondary diffuser Primary diffuser Primary nozzle The core of multiflam technology is the specialy designed mixing head, in which the fuel is distributed in multiple points and energy released to secondary and primary flames, making combustion more efficient then ever before. This is achieved by the recirculation of flue gases directly in the mixing head. Primary air Secondary nozzle Secondary nozzle Secondary air Schematic of the mixing head
51 Burner selection Oil burners size to, vers. LN multiflam Burner model RL/-A, version LN Combustion head M/-a Capacity in MBH,, Capacity in GPH#.. Burner model RL/-A, version LN Combustion head M/-A Capacity in MBH,, Capacity in GPH# ,,,,,,,,,,,,,,, -,,,,,,,,,,,,, GPH# GPH# Burner model RL/-B, version LN Combustion head M/-a Capacity in MBH,, Capacity in GPH#. Burner model Vers. Order No. RL/-A LN RL/-A LN RL/-B LN - -,,,,,,,,, GPH# Fuels # oil,,,,, The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) an installation altitude of, ft ( m) above sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
52 Scope of delivery / Accessories / Technical data Oil burners size to, version LN Scope of delivery RL RL RL Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, combustion manager with operating unit, UV flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Oil pressure switch in return Oil pump, fitted Oil hoses Accessories Intake flange for the connection of an air duct Combustion head extension Speed control O trim W-FM loose to fit into control panel Scope of delivery Accessories Additional accessories available on request. Technical data RL/-A LN RL/-A LN RL/-B LN Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.). () FLA at V A. Speed ( Hz) rpm,,, Fan wheel Colour red red red ø x x x. Combustion manager Model W-FM / W-FM W-FM / W-FM W-FM / W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Fuel Model SQM SQM SQM Mixing head Model SQM SQM SQM Pump, fitted Model TAC TAC TAC Oil solenoid valves V / (supply) W Model K V / (return) W Model K V / (supply) W Model H H V / (return) W Model G G Oil pressure switch bar (return fuel # oil - bar) Model DSA F DSA F DSA F Oil hoses DN, length in inch and (mm) / () / () / () Burner weight approx. lbs (kg) () () ()
53 Burner selection Gas burners size and, version LN Burner model G/-A, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, Burner model G/-A, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, - - -,,,,,,,,,,,,,,, -,,,,,,,,,, MBH MBH Burner model G/-B, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, Burner model G/-A, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, - - -,,,,,,,,,,,,,, -,,,,,,,,, MBH MBH Fuels capacity with combustion head open close Nat gas Burner model Vers. Order No. G/-A LN G/-A LN G/-B LN G/-A LN The capacity graphs are based on air temperature of F ( C) an installation altitude at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration in case of installation altitude above ft. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
54 Burner selection Gas burners size and, version LN Burner model G/-A, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, Burner model G/-B, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, - - -,,,,,,,,,,, -,,,,,,,,,,,,, MBH MBH Burner model G/-A, version LN Combustion head G/-LN Capacity in MBH Nat Gas,, - -,,,,,,,,,,,, The capacity graphs are based on air temperature of F ( C) an installation altitude at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration in case of installation altitude above ft. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. MBH Fuels capacity with combustion head open close Nat gas Standard burner motor: Insulation class F, protection IP. Burner model Vers. Order No. G/-A LN G/-B LN G/-A LN
55 Scope of delivery/accessories Gas burners size to, version LN Scope of delivery G G G G G Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, combustion manager with operating unit, UV flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two safety gas shut off valves Ignition pilot Air pressure switch Gas pressure switch Ratio controlled sliding sleeve in mixing head Stepping motor for Air regulator Gas butterfly valve Mixing head Accessories Intake flange for the connection of an air duct Combustion head extension Speed control O trim W-FM loose to fit into control panel Scope of delivery Accessories Additional accessories available on request.
56 Technical data Gas burners size to, version LN Technical data G/-A LN G/-A LN G/-B LN G/-A LN Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.). () () FLA at V A. Speed ( Hz) rpm,,,, Fan wheel Colour red red red red ø x x x. x. Combustion manager Model W-FM W-FM W-FM W-FM Model W-FM W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM SQM Fuel Model SQM SQM SQM SQM Mixing head Model SQM SQM SQM SQM Burner weight approx. lbs (kg) () () () () Technical data G/-A LN G/-B LN G/-A LN Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw) () (.). () FLA at V A. Speed ( Hz) rpm,,, Fan wheel Colour no color code green green ø x.-r x x Combustion manager Model W-FM W-FM W-FM Model W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Fuel Model SQM SQM SQM Mixing head Model SQM SQM SQM Burner weight approx. lbs (kg) () () () )
57 Burner selection Dual fuel burners size and, version LN Burner model RGL/-A, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil. Burner model RGL/-A, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil ,,,,,,,,,,,,,,, -,,,,,,,,,, GPH # GPH # Fuels # oil Nat gas Burner model Vers. Order No. RGL/-A LN RGL/-A LN The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
58 Burner selection Dual fuel burners size, version LN Burner model RGL/-B, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil Burner model RGL/-A, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil ,,,,,,,,,,,,,, -,,,,,,,,, GPH # GPH # Fuels # oil Nat gas Burner model Vers. Order No. RGL/-B LN RGL/-A LN The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP.
59 Burner selection Dual fuel burners size and, version LN Burner model RGL/-A, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil Burner model RGL/-B, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil - - -,,,,,,,,,,, -,,,,,,,,,,,,, GPH # GPH # - Burner model RGL/-A, version LN Combustion head G/-LN Capacity in MBH NG,, MBH #,, GPH # oil.. -,,,,,,,,,,,, The stated oil throughputs in GPH refer to # oil with a calorific value of, BTU/Gal. The capacity graphs are based on air temperature of F ( C) and installation at sea level. A reduction of burner capacity of % for every ft ( m) should be taken into consideration depending on installation altitude. Voltages and frequencies: The burners are equipped with three phase motor in - V, Hz as standard. Different voltage and frequency are available upon request. Standard burner motor: Insulation class F, protection IP. GPH # Fuels # oil Nat gas Burner model Vers. Order No. RGL/-A LN RGL/-B LN RGL/-A LN
60 Scope of delivery/accessories Dual fuel burners size and, version LN Scope of delivery RGL RGL RGL RGL RGL Burner housing, hinge flange, housing cover, Weishaupt burner motor, air regulator housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, atomising system with oil nozzle/s, combustion manager with operating unit, flame sensor, stepping motors, flange gasket, limit switch on hinge flange, fixing screws Combustion manager W-FM Two gas shut off valves Ignition pilot Gas butterfly valve Air pressure switch Gas pressure switches Ratio control sliding sleeve in mixing head Stepping motor for Air regulator Gas butterfly valve Mixing head Accessories Intake flange for the connection of an air duct Solenoid valve for air pressure switch test for cont. run fan or post-purge Combustion head extension Speed control O trim W-FM loose for installation in a remote control panel Scope of delivery Accessories Additional accessories available on request.
61 Technical data Dual fuel burners size to, version LN Technical data RGL/-A LN RGL/-A LN Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). (.). (.) FLA at V A. Speed ( Hz) rpm,, Fan wheel Colour red red ø x x Combustion manager Model W-FM / W-FM W-FM / W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Pump, fitted Model TAC TAC Oil solenoid valves V (supply) Model K H V (return) Model K G Oil pressure switch bar Model DSA F DSA F (return # oil - bar) Oil hoses DN, length in inch (mm) / () / () Burner weight approx. lbs (kg) () () Technical data RGL/-B LN RGL/-A LN Burner motor ~ - V Model W-D/-/K W-D/-/K Motor rating HP (kw). () () FLA at V A Speed ( Hz) rpm,, Fan wheel Colour red red ø x. x. Combustion manager Model W-FM / W-FM W-FM / W-FM Ignition unit Model W-ZG W-ZG Stepping motor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Pump, fitted Model TAC TC Oil solenoid valves V (supply) Model H H V (return) Model G G Oil pressure switch bar Model DSA F DSA F (return # oil - bar) Oil hoses DN, length in inch and (mm) / () / () Burner weight approx. lbs (kg) () ()
62 Technical data Dual fuel burners size and, version LN Technical data RGL/-A LN RGL/-B LN RGL/-A LN Burner motor ~ - V Model W-D/-/K W-D/-/K W-D/-/K Motor rating HP (kw) () (.). () FLA at V A. Speed ( Hz) rpm,,, Fan wheel Colour / ø no color / x.-r green / x green / x Combustion manager Model W-FM / W-FM / W-FM / W-FM W-FM W-FM Ignition unit Model W-ZG W-ZG W-ZG Stepping motor Air Model SQM SQM SQM Fuel Model SQM SQM SQM Mixing head Model SQM SQM SQM Pump, fitted Model TC TC (up to TC GPH / kg/h) TC (from GPH / kg/h) Oil solenoid valves V (supply) Model H H H V (return) Model G G G Oil pressure switch bar Model DSA F DSA F DSA F (return # oil - bar) Oil hoses DN, length in inch and (mm) / () / () / () Burner weight approx. lbs (kg) () () ()
63 Oil burner dimensions Size to d h b h b d r b approx.. ( mm)* d r l l * depending on oil preheater d d Burner Dimensions in inches and (mm) model b b b d d d d d h h l l r r MSZ/-A () () () () () M () () () () () () () () RMS/-A () () () () () M () () () () () () () () MSZ/-B () () () () () M () () () () () () () () RMS/-B () () () () () M () () () () () () () () RMS/-A () () () () () M () () () () () () () () LT/-A () () () () () M () () () () () () () () RL/-B () () () () () M () () () () () () () () RMS/-B () () () () () M () () () () () () () () RL/-A () () () () () M () () () () () () () () RMS/-A () () () () () M () () () () () () () () RL/-A () () () () () M () () () () () () () () RMS/-A () () () () () M () () () () () () () () RL/-A () () () () () M () () () () () () () () RMS/-A () () () () () M () () () () () () () () RL/-A () () () () () M () () () () () () () () RMS/-A () () () () () M () () () () () () () () Refer to burner manual for additional dimensions
64 Oil burner dimensions Size to d h h b b d r b approx.. ( mm)* d r l l * depending on oil preheater d d Burner Dimensions in inches and (mm) model b b b d d d d d h h l l r r RL/-A LN () () () () () M () () () () () () () () RL/-A LN () () () () () M () () () () () () () () RL/-B LN () () () () () M () () () () () () () () Refer to burner manual for additional dimensions
65 Gas burner dimensions Size to d b d d r b h h l l l d d l r b (Shown version LN) Burner Dimensions in inches and (mm) model b b b d d d d d h h l l l l r r G/-B ZM-NR () () () () () M () () () () () () () () () () G/-A ZM-NR () () () () () M () () () () () () () () () () G/-A ZM-NR () () () () () M () () () () () () () () () () G/-B ZM-NR () () () () () M () () () () () () () () () () G/-A ZM-NR () () () () () M () () () () () () () () () () G/-A ZM-NR () () () () () M () () () () () () () () () () G/-B ZM-LN () () () () () M () () () () () () () () () () G/-B ZM-LN () () () () () M () () () () () () () () () () G/-A ZM-LN () () () () () M () () () () () () () () () () G/-A ZM-LN () () () () () M () () () () () () () () () () G/-B ZM-LN () () () () () M () () () () () () () () () () G/-A ZM-LN () () () () () M () () () () () () () () () () G/-A ZM-LN () () () () () M () () () () () () () () () () G/-B ZM-LN () () () () () M () () () () () () () () () () G/-A ZM-LN () () () () () M () () () () () () () () () () Refer to burner manual for additional dimension
66 Gas burner dimensions Size to d b d d r b h h l l l d d l r b (Shown version LN) Burner Dimensions in inches and (mm) model b b b d d d d d h h l l l l r r G/-A LN () () () () () M () () () () () () () () () () G/-A LN () () () () () M () () () () () () () () () () G/-B LN () () () () () M () () () () () () () () () () G/-A LN () () () () () M () () () () () () () () () () G/-A LN () () () () () M () () () () () () () () () () G/-B LN () () () () () M () () () () () () () () () () G/-A LN () () () () () M () () () () () () () () () () Refer to burner manual for additional dimension
67 Dual fuel burner dimensions Size to d b b d d r h h d d l l r b l l (Shown version LN) Burner Dimensions in inches and (mm) model b b b d d d d d h h l l l l r r RGMS/-A NR () () () () () M () () () () () () () () () () RGMS/-B NR () () () () () M () () () () () () () () () () RGMS/-A NR () () () () () M () () () () () () () () () () RGL/-B ZM-NR () () () () () M () () () () () () () () () () RGMS/-B ZM-NR () () () () () M () () () () () () () () () () RGL/-A ZM-NR () () () () () M () () () () () () () () () () RGMS/-A ZM-NR () () () () () M () () () () () () () () () () RGL/-A ZM-NR () () () () () M () () () () () () () () () () RGMS/-A ZM-NR () () () () () M () () () () () () () () () () RGL/-B ZM-NR () () () () () M () () () () () () () () () () RGMS/-B ZM-NR () () () () () M () () () () () () () () () () RGL/-A ZM-NR () () () () () M () () () () () () () () () () RGMS/-A ZM-NR () () () () () M () () () () () () () () () () RGL/-A ZM-NR () () () () () M () () () () () () () () () () ) RGMS/-A ZM-NR () () () () () M () () () () () () () () () () Refer to burner manual for additional dimension
68 Dual fuel burner dimensions Size to d b b d d r h h d d l l r b l l (Shown version LN) Burner Dimensions in inches and (mm) model b b b d d d d d h h l l l l r r RGL/-A ZM-NR () () () () () M () () () () () () () () () () RGMS/-A ZM-NR () () () () () M () () () () () () () () () () RGL/-A ZM-LN () () () () () M () () () () () () () () () () RGL/-B ZM-LN () () () () () M () () () () () () () () () () RGL/-A ZM-LN () () () () () M () () () () () () () () () () RGL/-A LN () () () () () M () () () () () () () () () () RGL/-A LN () () () () () M () () () () () () () () () () RGL/-B LN () () () () () M () () () () () () () () () () RGL/-A LN () () () () () M () () () () () () () () () () RGL/-A LN () () () () () M () () () () () () () () () () RGL/-B LN () () () () () M () () () () () () () () () () RGL/-A LN () () () () () M () () () () () () () () () () Refer to burner manual for additional dimension
69 Fuel systems GLZ (oil side) GLT/GLT/LT (oil side) RGL (oil side) a a a a a V V V V V V V V V P M V V a a a a a a MSZ/-A, MSZ/-B RL to RL RGL to RGL (oil side) RMS to RMS RGMS to RGMS (oil side) Pump and oil preheater fitted a V P V V V V P M V P M a a b a a a a
70 Fuel systems RGMS/ (oil side) With separate pump and preheater stations RL to RL vers. LN RGL to RGL vers. LN (oil side) b b P V V V V V P M V V P M a a a b a b a G to G (gas side vers. NR) RGL to RGL vers. LN (gas side) G to G vers. LN b b The gas train schematics show typical configuration for UL gas train. The actual gas train shipped with burner might have different configuration depending on applicable code and regulation. P P P P Legend Ball valve Gas pressure regulator Low gas pressure switch Double main SSOV b Pilot gas valves High gas pressure switch Pilot train ball valve Pilot gas pressure regulator Gas butterfly valve Burner Oil pump Strainer Oil solenoid valve, normally closed (V connected in series with a) a Oil solenoid valve, normally closed (V connected in series with, installed against the flow direction) b Bypass solenoid valve, normally open Oil solenoid valve, normally closed a Oil solenoid valve, normally closed for stage, and b Oil solenoid valve, normally open a Oil pressure switch in return b Oil pressure switch in supply (optional, not shown) Oil regulator Nozzle head with shut off device a Nozzle head without shut off device Oil preheater a Temperature switch b Temperature sensor Pt (to monitor minimum oil temperature) External oil filter
71 Pump and preheater stations Scope of delivery pump station Pump unit (screw spindle pump with motor), pressure gauge, vacuum gauge, pressure regulating valve, ball valves, suction flange, pressure flange including counter flanges, screws and washers, suction side filter. All parts are fully assembled on an oil drip tray. The pump station is built as one of two different versions - either as a single station unit with one pump, or as a twin station unit with two pumps with one pump serves as a backup unit. Should one pump fail, it is possible to quickly switch over to the other. Only tried and tested makes of pump are used. The pumps are carefully matched to the capacity of the burner. Scope of delivery - preheater stations Preheater stations are supplied fully assembled on an oil drip tray. The preheater ensures constant regulation of the oil temperature and thus the viscosity of the fuel oil. There are two basic versions of the preheater station available:. Electric preheater. Medium preheater WEV.. and MV.. type preheaters are used. MV medium oil preheater Medium preheaters are high capacity, forced circulation heat exchangers. High capacity is achieved with a compact, space saving construction. Hot water, steam or thermal fluid can be used as heating media. The oil preheaters guarantee largely stable oil temperatures and thus good combustion figures. The oil temperature achieved depends on the heating medium used. When selecting and sizing, please refer to the oil temperature diagrams in chapter. of the technical brochure Weishaupt electric and medium oil preheaters, print No.. Weishaupt medium oil preheaters can be used universally. It is possible to change the medium at any time. The preheaters are used either alone or in conjunction with an electric oil preheater. If operating steam at more than PSI or hot water between F ( C) and F ( C) is continuously available, then an electric preheater is not required. This is also possible if installation with the above minimum pressures or temperatures can be operated with # oil or gas. If the medium temperature is not sufficient to adequately preheat the fuel oil, then the electric oil preheater provides the additional heat required. The electric oil preheater heats the oil for the start up of the installation. If the required medium temperature is available then the station switches over to the medium oil preheater thus saving on expensive electrical energy. Suitable connection for medium oil preheaters can be selected, depending on the medium. If medium oil preheaters are provided without electric oil preheaters, a temperature controller must be used with the medium connection fittings. Medium connection fittings are available as an option. General instructions When starting a boiler from a cold condition with heavy oil, an electric oil preheater capacity must be provided for at least % of the boiler rating. Planning and installation instructions Oil filter, air/gas separator, circulation tank, pump station and oil preheater station must be installed as close as possible to the burner. On burners with separate oil preheater the time required for oil circulation during start up depends on the length of the pipework between the burner and the air/gas separator or circulation tank. The shorter the pipeline, the shorter the period between heat being called for and oil release and burner start after a controlled shutdown.
72 Pump and preheater stations Specification Burner Technical data - Pump Version with pump Version with pumps Rating Flow rate in GPH (l/h) Speed Motor rating Pump model Pump model GPH (based on cst) rpm HP (kw) Pump stations - frequency Hz (,),. (.) SPF - SPZ - (,),. (.) SPF - SPZ - (,),. (.) SPF - SPZ - Model Quantity Medium preheater Electric preheater (EV) oil flow in GPH (kg/h) Oil flow in GPH (kg/h) at ΔT = F ( C) Preheater stations WEV./ () WEV./ () WEV/. () WEV/ () MVC with temperature regulator. () MVC without temperature regulator. () MVA with temperature regulator () MVA without temperature regulator ()
73 That is not a Facade. Weishaupt has been one of the leading company in heating and combustion industry since years with headquarter in Schwendi and branches all over the world. That is Reliability. Weishaupt is Reliability. The family business in Schwendi was established by Max Weishaupt in. Represented in countries by branch offices and subsidiaries Weishaupt is international leader in the areas of combustion technology and heating applications. Trustworthy, quality, good customer service, innovation and experience are values on which the Pioneer Max Weishaupt established his company. All this combined in a word is reliability. Therefore stands Weishaupt today.
74 That is not an Imagination. Continuous research and development at Weishaupt ensure environmental friendly and efficient burners. That is Reliability. Test facility at Weishaupt R&D centre
75 Developing improvement. Weishaupt recognizes the signs of time and researches perpetually to get more efficient and environmental friendly burner systems. This way not only Weishaupt prevents largely unnecessary energy cost but also actively contributes in conserving the environment.
76 Weishaupt Corporation Danville Road Mississauga, ON LT H, Canada Ph: () Fax: () Weishaupt America Inc. Millenium Drive, Unit A Elgin, IL, USA Ph: () Fax: () Print No., June Printed in Germany. All rights reserved. Regular maintenance reduces heating costs and environmental pollution. Only a properly adjusted burner can save energy and be environmentally friendly. Behind each Weishaupt burner stands the whole Weishaupt customer service organization. The outstanding efforts made in maintenance and service justify the enormous trust placed in Weishaupt s burners, for at Weishaupt product and customer service belong together. Weishaupt customer service is there for you all year round. Whenever you need help, be it the supply of spare parts, technical advice or a site visit. We are there when you need us.
Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA
Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA Description Weishaupt burners of sizes 30 to 70 were specially designed and developed for industrial
More informationproduct WM 20 oil, gas and dual fuel version Weishaupt monarch WM20 burners compact and powerful Information on oil, gas and dual fuel burners
product Information on oil, gas and dual fuel burners WM 20 oil, gas and dual fuel version Weishaupt monarch WM20 burners compact and powerful Advanced technology starts from tradition The new monarch
More informationproduct WM 30 oil, gas and dual fuel version Weishaupt monarch WM30 burners highly efficient and versatile
product Information on oil, gas and dual fuel burners WM 0 oil, gas and dual fuel version Weishaupt monarch WM0 burners highly efficient and versatile Advanced technology starts from tradition The new
More informationWeishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA
Weishaupt WG0 and WG20 gas burners LN (Low NO x ) version 2/2002 CA New W series capacity range The Weishaupt WG0 and WG20 gas burners join the WG5, WG30 and WG40 to complete the line-up of products successfully
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationProduct Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT
The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures
More informationPROFIRE -E SERIES BURNERS
PROFIRE -E SERIES BURNERS 8.4-42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements Integration Starts with the Burner Suitable for firetube, firebox and watertube
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationLOW NOx MODULATING GAS BURNERS
RS/E - RS/EV BLU SERIES LOW NOx MODULATING GAS BURNERS RS/E - RS/EV BLU SERIES RS 300/E BLU 500/1350 3800 kw RS 400/E BLU 800/1800 4500 kw RS 300/EV BLU 500/1350 3800 kw RS 400/EV BLU 800/1800 4500 kw
More informationLight oil burners. One stage operation
Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV BLU Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV C01 models that extend his max output up to
More informationBryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired
Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20
More informationRS /E-EV C01 SERIES
The well-known RS 300-800/E-EV Burner Series, till now available up to 8 MW, has been upgraded with two new powerful burner models, the RS 1000-1200/E-EV models that extend his max output up to 12 MW and
More informationproduct Ultra Low NO x emissions WM-G10 ZM-PLN and WM-G20 ZM-PLN monarch burners (290 10,240 MBH) Information on Ultra Low NO x gas burners
product Information on Ultra ow NO x gas burners Ultra ow NO x emissions WM-G0 ZM-N and WM-G20 ZM-N monarch burners (290 0,240 MBH) A new class of emissions: Ultra-ow NO x Test-firing chambers for medium
More informationRIELLO 40 GS/M SERIES
The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.
More informationDELTA-TE III. Nozzle-mix line burner
4-21.7-1 DELTA-TE III Nozzle-mix line burner Combines excellent flexibility with extreme low emissions for direct firing Especially designed for firing in low oxygen, high humidity and/or inert process
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationINDITHERM. Low temperature gas burners
INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout
More informationR-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions
R-Series Oil Burners Maximum Performance. Minimum Maintenance. Oil Riello Burners a world of experience in every burner we sell Across North America and the world over, Riello sets the standard in reliable,
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500 Bio B10 E90-803-001-001-00 Rev 7-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...
More informationChemical Processes in the Combustion
FLAMES Chemical Processes in the Combustion C + O 2 CO 2 + 94,1 kcal C x H y + [2x+ y / 4 ] O 2 x CO 2 + y / 2 H 2 O + z kcal Burner Flame Air Fuel Air Flame Ignition Ignition of Flames: Ignition Energy
More informationGas and dual fuel burners Burner sizes 50 and 90
Gas and dual fuel burners Burner sizes 5 and 9 Group 2 apacity.4-5. MBtu/h Burner sizes 5 and 9 M/MH Turndown ratio, up to :8, firing on gas apacity regulation: modulating (M) for gas, two stage (H) for
More informationCODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80
Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009 Thermal power - Output Operation Fuel Electrical
More informationTWO STAGE HEAVY OIL BURNERS
TWO STAGE HEAVY OIL BURNERS PRESS N SERIES PRESS 30 N 85/171 342 kw PRESS 45 N 114/205 513 kw PRESS 60 N 171/342 684 kw PRESS 100 N 285/490 1140 kw The PRESS N series of burners covers a firing range from
More informationOil burners Brûleurs fioul Stookoliebranders
Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement
More informationSpecifications of V-Line burners
Duct Burners - V-Line 4-22.5-7 Specifications of V-Line burners V-Line burner firing on natural gas - constant combustion air 60 F - 21% O 2 combustion air - 50% rel. humidity - natural gas with 1000 Btu/ft³
More informationRental Boiler Specifications (Nebraska Boiler)
Rental Boiler Specifications (Nebraska Boiler) ESI's 72,000 pph trailer-mounted watertube steam boilers are designed and built in accordance with ASME Code. Each boiler is arranged for natural gas or #2
More informationDistributed By: M&M Control Service, Inc Building Technologies
Building Technologies Combustion Control Systems Count on Siemens. Siemens Building Technologies, the worldwide industry leader in combustion controls, delivers globally approved products specifically
More informationRIELLO ARRAY. High Efficiency Condensing Boiler MBH.
RIELLO ARRAY High Efficiency Condensing Boiler 1000-4000 MBH www.rielloboilers.com POWER RANGE ARRAY 1000-2000 ARRAY 3000-4000 MODEL INPUT POWER MBH Number of Modules AHRI Thermal Efficiency % Turndown
More informationINDITHERM. Low temperature gas burners
INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout
More informationOnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!
OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.
More informationVCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower
VCLEARFIRE High-Efficiency, Commercial Steam Boiler 9.5-60 Horsepower High-Efficiency, Low-Emissions Steam Boiler in a Compact Footprint The Cleaver-Brooks compact, gas-fired ClearFire -V vertical boiler
More informationCclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU
Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU Unmatched efficiency and low-nox technology in a condensing boiler The ClearFire-C is a completely integrated solution with heat exchanger,
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded
More informationV-Line. Nozzle-mix line burner
V-Line Nozzle-mix line burner Duct Burners - V-Line 4-22.5-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane. Suitable for operation in variable process air-flows. Stainless
More informationHCLEARFIRE. High-efficiency, modular steam boiler HP
HCLEARFIRE High-efficiency, modular steam boiler 10-60 HP High-Efficiency, Low-Emission Steam Boiler in a Compact Footprint The ClearFire -H compact, gas-fired horizontal boiler is designed specifically
More informationCONDENSING HIGH EFFICIENCY BOILERS
Built by 3I Innovative Industrial Inc. ABS Series CONDENSING HIGH EFFICIENCY BOILERS ABS 1500-2000-2500-3000-4000MBH Cast aluminum heat exchanger 10 to 1 turndown ratio Honeywell Sola boiler control system
More informationST 40 Oil Burner. Installation & Maintenance Manual
ST 40 Oil Burner Installation & Maintenance Manual 178 093 13 Thank you for choosing a Nu-way burner. As you would expect from a Company who has a pedigree of more than 75 years in the heating industry,
More information96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency
NX COMMERCIAL INDUSTRIAL HEATER Condensing Gas Water Heating System 96% Thermal Efficiency Hubbell NX Input 200 to 800,000 BTU/H Easy use touch screen display Stainless steel heat exchanger Floor or wall
More informationBosch Uni 7000F Cast Iron Hot Water Boiler
Technical Data Sheet Bosch Uni 7000F Cast Iron Hot Water Boiler Standard Engineering Specifications The boiler(s) shall be sectional cast iron hot water boiler(s) of full three pass design, suitable for
More informationBUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers
BUDERUS BUDERUS G1 1 1 G1 G1 G1Boilers Cast Iron Commercial High Efficiency Combustion Efficiencies Up to 88.2% 0 to,982 MBH Output Thermostream Design Eliminates Thermal Shock Superior Equipment by Design
More informationAPX. Nozzle-mix line burner
APX Nozzle-mix line burner Duct burners - APX Burner 4-21.9-1 Nozzle-mixing line burner for use with low pressure natural gas, propane and butane Eliminates leakage with its single-piece, aluminium extrusion
More informationFXLF-9. High Efficiency Water Heaters and Boilers
FXLF-9 High Efficiency Water Heaters and Boilers Small Steps Big Plans Today s boiler and water heater markets demand high efficiency in smaller spaces both mechanical room space and equipment size. RBI
More informationFlame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660
Selectivity Adjustable by Means of - High Pass Frequency Filter - Gain - Threshold Different Adjustments for Different Conditions (e.g. According Fuel or Combustion Technology) Possible, to be Activated
More informationTypical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000
s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified
More informationSAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER
SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section
More informationCCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU
CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU Unmatched Efficiency and Low-NOx Technology in a Condensing Boiler The ClearFire -C is a completely
More informationTypical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000
s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified
More informationNMC Nozzle Mix Gas/Oil Combination Burners
NMC Nozzle Mix Gas/Oil Combination Burners NMC-1 Edition 10-08 Burns most gaseous fuels and No. 2 oil Sealed-in capability Stable flame over entire operating range Preheated air to 800ºF (425ºC) Gas pilot
More informationINSTRUCTION MANUAL FOR OIL BURNER MODELS
INSTRUCTION MANUAL FOR OIL BURNER MODELS X500-2 Low voltage 12v dc Brushed motor E90-803-001-005-01 Rev 4-1 - Contents Technical specifications Technical data...3 Working field...3 Dimensions...4 Head
More informationEngineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004
Engineering Bulletin Gas Heat for M-Series and T-Series Climate Changer Air Handlers March 2004 CLCH-PRB010-EN Preface Gas heat can be a good heating option for any of the following applications: Climates
More informationDocument code: 1 (10) Issuing date: Status:
Document code: 1 (10) Project : MULTI FUEL CFB BOILER SIMULATOR Author: Approved: Language: JJA Document title: SYSTEM DESCRIPTION DUCT BURNERS Submitted for: Customer reference: Other information: Document
More information"NP" & "RG" AIRFLO. In-duct firing line burner
"NP" & "RG" AIRFLO In-duct firing line burner Duct burners - NP & RG AIRFLO 4-21.5-1 For direct fired fresh air heating applications Operates economically (100 % thermal efficiency) and installs easily
More informationG215 G315 Cast Iron Residential Boilers
G215 G315 Cast Iron Residential Boilers Design Advantage Superior Heating Ø High Efficiency - AFUEs Above 86% Thermostream Design Eliminates Thermal Shock Flexible, Corrosion Resistant GL-180M Cast Iron
More informationForced draught gas burner
Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1
More informationPCH/new Series. High performance, total flexibility
PCH/new Series High performance, total flexibility PCH/new Installation in Air Handling Unit Very Low Emissions NOx lower than 30 ppm : Class 5 Capacity Range 14 models from 5 kw to 400kW Automatic Control
More informationComplete burner management in a compact, affordable system
Touchscreen Mini Mk8 Controller Complete burner management in a compact, affordable system The Mini Mk8 is a cutting-edge Micro-Modulating system that provides an easily programmable and flexible means
More informationCONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS
FFC-2 CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS The gas-fired Futera Fusion TM now brings the field-proven performance of Futera III Modulation boilers and water heaters
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R
178 013 03-2 2016-05-26 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 10 E R DESCRIPTION Components 1. Scale, nozzle assembly 2. Nozzle assembly adjustment
More informationFXLF-4. High Efficiency Water Heaters and Boilers
FXLF-4 High Efficiency Water Heaters and Boilers Efficient Power, Sized to Your Vision The Futera XLF is designed with 5-to-1 turndown, up to 88% efficiency, and backed by RBI reliability and ease of service.
More informationRTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating
cod. Doc-0079191 rev. 3 12/2017 High efficiency commercial heating RTC Stainless Steel Condensing Floor Standing Boilers Technical data sheet High water content 3-pass stainless steel (316Ti) condensing
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A
178 038 51-2 2016-07-08 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 30 A DESCRIPTION Components 1. Shrouded disc 2. Nozzle 3. Ignition electrodes 4. Nozzle
More informationComplete Boiler Management in a Compact, Affordable System
Touchscreen Mini Mk8 Controller Complete Boiler Management in a Compact, Affordable System The Mini Mk8 is a cutting-edge Micro-Modulating system that provides an easily programmable and flexible means
More informationOriginators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE RW SERIES STEAM AND WATER BOILER 8,500,000 TO 21,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler RW2100-W-FDGO Steam Boiler RW1050-S-150-FDG Originators of
More informationOriginators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE EB SERIES STEAM AND WATER BOILER 3,200,000 TO 10,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Steam Boiler EB75-S-150-FDG Water Boiler EB200-W-FDGO Originators of the
More informationMONOBLOCK NG SERIES GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL
MONOBLOCK NG SERIES GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL MODULATING OPERATION ECO 50 NG ECO 55 NG ECO 60 NG ECO 65 NG ECO 70 NG www.ecostar.com.tr DEAR USER, ECOSTAR ECO 50 NG, ECO
More informationFlame115 Radiant. Flame115 Specifications. Flame115 Accessories
PORTABLE HEATERS Whether you re curing concrete, warming equipment or heating spaces, you ll work faster and smarter with Veloci portable heaters. Our versatile, Italian-engineered radiant and forced-air
More informationEclipse AirHeat Burners
Design Guide No. 135, 7/99 L00060 Eclipse AirHeat Burners AH Series Version 2.00 (Patent Pending) Eclipse Combustion COPYRIGHT Copyright I999 by Eclipse Combustion, Inc. All rights reserved worldwide.
More information"HC" AIRFLO. In-duct firing line burner
"HC" AIRFLO In-duct firing line burner -.- High heat release up to.5 MW per unit of burner length (05 mm) Clean combustion with low CO and NO x emission levels Minimal process air pressure drops locally
More informationDomestic Hot Water Heaters and Boilers FTIIIC-6
Domestic Hot Water Heaters and Boilers FTIIIC-6 Full Modulation, High Efficiency Hot Water Supply and Hydronic Heating Boilers The gas-fired Futera III brings the field-proven performance of Futera Series
More informationRL 28/2-38/2-50/2 Low - High Operation
Installation, use and maintenance instructions Light Oil Burners RL 28/2-38/2-50/2 Low - High Operation C6505050 CONTENTS WARNING TECHNICAL DATA..............................page 3 Burner models.....................................
More informationFTIIIC-10. Domestic Hot Water Heaters and Boilers
FTIIIC-10 Domestic Hot Water Heaters and Boilers Full Modulation, High Efficiency Hot Water Supply and Hydronic Heating Boilers The gas-fired Futera III brings the field-proven performance of Futera Series
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationNew Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.
New Features RIELLO ARRAY v2.0 High Efficiency Condensing Boiler 1000-4000 MBH www.rielloboilers.com THE ULTIMATE IN EFFICIENCY, REDUNDANCY & RELIABILITY The Riello Array is a pre-packaged boiler plant,
More informationC Tahiti. condensing
C 227-01 m a d e i n I ta ly Tahiti condensing Condensing, pre-mixed, wall-hung boilers KC 24 KC 28 - KC 32 indoor, instantaneous, combination boilers KR 24 KR 38 - KR 32 indoor, central heating only boilers
More informationCOMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS
CONDENSING TANKLESS WITH INTEGRATED RECIRCULATION PUMP COMMERCIAL-GRADE RESIDENTIAL Ultra-Low NOx gas tankless water heaters with condensing technology featuring an up to 0.95 Uniform Energy Factor (UEF)
More informationSteam Fundamentals. (in heating & processing applications)
Steam Fundamentals (in heating & processing applications) Introduction Common Heat Energy conveyers: Thermal Oil Hot water Steam Electrical Electric Heaters Electrodes (High Current) Steam Fundamentals
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,
More informationCI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS
CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired
More informationINDUSTRIAL MICRODIFFUSION OIL BURNERS
Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION OIL BURNERS Models MD-25-O MD-2500-O December 2012 Copyright 2012 Periflame, Design Guide 112 Industrial Oil Burners, 12/01/2012 Page 1 Table
More informationA-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents
Boiler specifications A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents Burner General: Q. Burner and burner safeguards shall comply with the CGA
More informationIndustrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation
Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating
More informationProviding sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A
178 017 55-1 2016-05-19 Providing sustainable energy solutions worldwide Installation- and maintenance instruction B 45A DESCRIPTION Components 1. Flame cone 2. Ignition electrodes 3. Nozzle assembly
More informationDUOBLOCK DUAL FUEL (GAS-HEAVY OIL) BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL
DUOBLOCK DUAL FUEL (GAS-HEAVY OIL) BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL MODULATING OPERATION ECO 250 ECO 300 ECO 350 ECO 400 ECO 450 ECO 500 ECO 600 ECO 700 ECO 800 ECO 900 www.ecostar.com.tr
More informationPREEVA air handling unit
APPICATINS Heating, ventilation, cooling, heat recovery >> FACTRIES >> commercial premises >> WAREHUSES >> HAS >> SPRTS & EISURE >> PACES F WRSHIP >> RESTAURANTS PREEVA air handling unit www.reznor.eu
More informationTermEfekt USER S MANUAL AIR HEATER. Model PGA 14
Przedsiębiorstwo Produkcyjno-Wdrożeniowe ARAJ sp. z o.o. 55-080 Kąty Wrocławskie, ul. Mireckiego 30 POLAND USER S MANUAL AIR HEATER TermEfekt Model PGA 14 Kąty Wrocławskie, 2004 Product identification
More informationRL 70/2-100/2-130/2 Low - High Operation
Installation, use and maintenance instructions Light Oil Burners RL 70/2-100/2-130/2 Low - High Operation C6505052 CONTENTS WARNING TECHNICAL DATA............................. page 3 Burner models.....................................
More informationDESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS
INTEGRAL FAN BURNERS 43, 53, 63 Supplement 600- July 996 DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS Integral Fan (and) Shutter Section (hinged for quick access to internals) Combustion Air Interlock
More informationHigh Efficiency Commercial Gas Water Heaters
High Efficiency Commercial Gas Water Heaters 500,000 to 1, 300,000 Btu/hr Less Than 30 ppm NOx Up to 87% Thermal Efficiency The High-Efficiency, High-Output Compact Water Heater First Power-Fin production
More informationMODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU
MODEL M5M High-Efficiency Packaged Watertube Boiler 2.0-6.0 MMBTU Low Emissions, High Efficiency Whether your application is a small batch load for food processing, or you are considering a hybrid heating
More informationDOM-5. Domestic Hot Water Heaters & Boilers
DOM-5 Domestic Hot Water Heaters & Boilers Unlike other manufacturers, which rely solely on achieving high operating efficiency, the Dominator Series is designed for total efficiency based on operating
More informationLOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS
FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal
More informationTake Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series
Commander Series Ultra Low NOx Commercial Gas Water Heaters Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander
More informationSolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.
SolarWall Fan Units Introduction The SolarWall fan units are designed to be used maximize the supply of solar heated air into the building via fabric ducting. The units are complete with modulating dampers
More informationBENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS
BENSN... EnviroAir Gas Fired Heating, Ventilation & Cooling Units... AMBIRAD HEATI NG AND VENTILATIN S LUTINS EnviroAir... Gas Fired Heating, Ventilation & Cooling Units... The Benson EnviroAir is a new
More information15 20 kw kw kw
Burner Set-up Details 15 20 kw 20 26 kw 29 36 kw Riello RDB2 Please read these instructions carefully before commissioning and using this appliance. To be retained by the householder HEALTH AND SAFETY
More informationADF/ADFH 300 and 500
MODEL ADF/ADFH DIRECT-FIRED SYSTEMS TECHNICAL DATA Four Sizes - 300, 500, 700, 1200 Horizontal Configuration with Full Curb Cap Base Horizontal or Vertical (down) Discharge Indoor/Outdoor Installation
More informationG315/6 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC2 THRU NVC6 ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx WITH CONTROLINKS CONTROLS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas
More information