Dehumidifiers. Model 1830/1850/1850F/1850W. OTHER PARTS (Not Shown)
|
|
- Dwain Powers
- 6 years ago
- Views:
Transcription
1 Effective Date: April, 0 Dehumidifiers Model 0/0/0F/0W A B 0 A B Filter, 0 x x EZK (0 & 0)* Filter, x x EZK (0F Only) Internal Control Board User Interface Assembly Wiring Access Door UI Control Hole Cover * Filter Access Door 0/0 Outlet Duct Panel * 0 Backflow Damper * Inlet Duct Panel * Outlet Cover * 0 Pint Dehumidifier Fan Pint Dehumidifier Fan Transformer and Wire Harness * Not Compatible with 0F **Drain tube only included with 0F 0 A B C 0A 0B Low Temperature Sensor High Temperature Sensor Leveling Foot* Compressor Run Capacitor, 0pt/pt, MFD, 0VAC Fan Run Capacitor, MFD, 0VAC, used on Models 0 and with Serial Number before 0A0 Fan Run Capacitor, MFD, 0VAC, used on Models 0 and with Serial Number 0A0 or later Fan Run Capacitor, MFD, 0VAC, used on Models 0(F)(W) and RH & Temp Sensor Drain Tube + Fittings** Compressor Overload Switch, 0pt Compressor Overload Switch, pt OTHER PARTS (Not Shown) Low Profile Condensate Pump Basement Kit (-0 N/O Dampers, -0 N/C Dampers & Transformer) Digital Dehumidifier Control (for all current dehumidifiers) Living Space Duct Kit ( of insulated flex duct with quick install grilles and reducers) Dehumidifier Hanging Kit 0 0 P.O. Box Madison, WI 0- Phone: 00/-0 Fax: 0/- Form No. 0B. Printed in the U.S.A 0 Aprilaire Division of Research Products Corporation
2 Model 0/0F/0W A B 0 Filter, x x EZK (0) Filter, x x EZK (0F) Internal Control Board, Deh User Interface Assembly, Deh Wiring Access Door, AA Deh Hole Cover, UI Ctrl, Deh Door, Filter Access, AA Deh Outlet Duct Panel, Deh Backflow Damper, 0, Deh Inlet Duct Panel, AA Deh Cover, Outlet, AA Deh 0 0 A B 0 Fan, 0pt Deh, with 0MFD Capacitor (0) Wire Harness, Power, Deh Sensor, Low Temperature, Deh Sensor, High Temperature, Deh Leveling Foot, Deh Capacitor, 0MFD, 0VAC Capacitor, 0MFD, 0VAC Capacitor, MFD, 0VAC RH Sensor, Deh Drain Tube + Fitting Compressor Overload Switch 0
3 Model 0A with R0A A B 0 Dehumidistat Control Assembly Digital Dehumidifier Control Backflow Damper Impeller with Bracket (Blower Assembly) Leveling Foot Control PCB Assembly High Temperature Cutout Switch Low Temperature Cutout Switch Filter Access Door Assembly Dehumidistat Hole Cover Outlet Cover Plate Air Filter Inlet/Outlet Screen Duct Collars Auxiliary drain pan Capacitor, µf Compressor Overload Switch Condensate Drain Hose Assembly 0VA Transformer with Wire Harness Capacitor, 0MF for Impeller OTHER PARTS Low Profile Condensate Pump (Condensate pump with 0 condensate hose) Living Space Duct Kit ( of insulated flex duct with quick install grilles) Living Space Duct Kit ( of insulated flex duct with quick install grilles and reducers) Part No. replaced by Part No. replaced by 0 0 0
4 Model 0A/0A/0A
5 PART NO. A B 0 A B A B Filter Drain Trap/Collars/Manual Backflow Damper * Blower/Motor Assembly, 0A/0A and 00/0/0 Blower/Motor Assembly, 0A and 0/0 Power Supply Board Power Supply Board (new style without integrated transformer) Control Board Kit *** Sensor Board Duct Collars Drain Trap and PVC Elbow Filter Door ** Condensate Drain Hose Assembly (included with Model 0A only) LED Control Door 0 VA Transformer Capacitor, 0µF (Model 0A only) Capacitor, µf Daughter Board High Temperature Cutout Switch Compressor Overload Switch, 0A/0A Compressor Overload Switch, 0A Frost Sensor OTHER PARTS External Control **** Convertible Installation Kit (-N/O Damper, -N/C Damper and Transformer) Distributor and nozzle, 0A/0A Low Profile Condensate Pump (condensate pump with 0 condensate hose) Living Space Duct Kit ( Of Insulated Flex Duct With Quick Install Grilles) Living Space Duct Kit ( of insulated flex duct with quick install grilles and reducers) Identifying Type of Control by Terminal Block Model 0A/0A/0A Model 00/0/0/0/0 0 See Table Below * The backflow damper (Part No. ) is compatible with all Models 0A, 0A, but only with Model 0A with Serial Numbers greater than 0AA0. ** Part is the blue/gray door; the almond colored doors are no longer available. *** If control board being replaced is currently used with a Model 0 Control, the control must be replaced with a Model Control. **** Only use a Model 0 Control to replace an existing Model 0 control with units produced before Serial Number 0AAXXXXXX. NO. PART DESCRIPTION Compatible With QTY/CTN PART NO. A Power Supply Board Control Board without DH Terminal B Power Supply Board (new style without integrated transformer) Control Board with DH Terminal 0 DH Terminal implemented on all units with Serial Number 0AAXXXXXX or later P.O. Box Madison, WI 0- Phone: 00/-0 Fax: 0/- Form No. 0B. Printed in the U.S.A 0 Aprilaire Division of Research Products Corporation
DEALER PARTS LIST DEHUMIDIFIERS. Model 1830/1850/1850F/1850W 17A 17B 17C
Effective Date: September 1, 2015 Revised Date: October 6, 2015 5 DEALER PARTS LIST Model 1830/1850/1850F/1850W 4 18 3 9 10 1A 1B 13 20A 20B 11A 7 11B 14 2 17A 17B 15 8 6 17C 16 19 NO. PART DESCRIPTION
More informationModel 1820 Dehumidifier
Model 1820 Dehumidifier Installation Instructions SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing.
More informationModel 1870F Dehumidifier Installation and Operating Manual
Model 1870F Dehumidifier Installation and Operating Manual ON/OFF button used to turn dehumidifier on and off Up/Down buttons used to change humidity setting Dehumidifer Control Outlet MODE button used
More informationMODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE
MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE Application Primary Zone to Dehumidify Secondary Zone to Dehumidify Control Type Application Sheet No. Single Zone Whole House or Basement
More informationModel 1850F Dehumidifier Installation and Operating Manual
Model 1850F Dehumidifier Installation and Operating Manual ON/OFF button used to turn dehumidifier on and off Up/Down buttons used to change humidity setting Dehumidifer Control Outlet MODE button used
More informationAprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870
Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870 Table of Contents Troubleshooting Diagnostic Codes... 2 E1... 2 E2, E3... 3 E4.4 E5, E6... 7 E7, E8... 8 E9.9 Verifying Capacity...
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationModel 1870 & 1870W Dehumidifier Installation Instructions
Model 1870 & 1870W Dehumidifier Installation Instructions SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation
More informationModel 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions
Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions ON/OFF button used to turn the ventilator on and off Up/Down buttons used to change humidity or vent time setting
More informationAprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850
Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850 Table of Contents Troubleshooting Diagnostic Codes... 2 E1, E2... 2 E3, E4... 3 E5, E6 & E7... 7 E8... 8 E9 9 Verifying Capacity... 10 Water
More informationHumidifiers Dealer Parts List Model 400/400M Humidifiers
Effective Date: September 1, 2012 Humidifiers Dealer Parts List Model 400/400M Humidifiers MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base (blue/gray) 1 4734 4734
More informationHumidifiers Dealer Parts List
Effective Date: July, 204 Revised Date: March 20, 205 Humidifiers Dealer Parts List Model 400/400M Humidifiers 6A 6B MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base
More informationHumidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.
Effective Date: January, 0 Humidifiers Model 00/00M Humidifiers B B B B B B Base (blue/gray) Cover (blue/gray) Automatic Digital Humidifier Control Name Plate (blue/gray) Hole Plug (blue/gray) MODEL 00
More informationCAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS
DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location
More informationSafety and Installation Instructions Model 1700
Dehumidifier Filter Access Humidity Control Inlet Filter Access Outlet Service Access Port Wiring Access Wire Routing Port Drain On/Off Switch Safety and Installation Instructions Model 1700 INSTALLER
More informationS1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION
Johnson Controls Unitary Products S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions Safety Instructions WARNING 1. 120 Volts may cause serious injury from electric shock. Disconnect
More informationInstallation, Safety & Maintenance Manual Model 1750A/1770A
Central Dehumidifier Filter Access Humidity Control Inlet Outlet Service Access Port Filter Access Wiring Access Wire Routing Port Drain On/Off Switch Installation, Safety & Maintenance Manual Model 1750A/1770A
More informationModel 1750A/ 1770A Dehumidifier Installation Instructions
Model 1750A/ 1770A Dehumidifier Installation Instructions Safety Instructions WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed
More informationAir Cleaners Dealer Parts List
Effective Date: August, 0 Revised Date: August, 0 Air Cleaners Dealer Parts List Aprilaire Model 000 Air Cleaner (Before April 0) Release Date May 00 Release Date Prior May 00 QTY/CTN PART NO. A B 9 0
More informationQuest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest Dry Quest 110 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate
More informationQuest 105, Dry155, and 205 Dual
Quest 105, Dry155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More informationQuest Dry 105, 155, and 205 Dual
Quest Dry 105, 155, and 205 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More informationModel 76 Dehumidifier Control Installation Instructions
Model 76 Dehumidifier Control Installation Instructions READ AND SAVE THESE INSTRUCTIONS The Model 76 is for use with any dehumidifier as an EXTERNAL CONTROL, including Aprilaire Models 1830, 1850(F)(W),
More informationQuest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest Dry 150 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationHealthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.
PRODUCT SPECIFICATIONS INDOOR AIR QUALITY HCWHD Healthy Climate Whole-Home Dehumidifier Bulletin No. 210699 November 2017 Supersedes April 2017 MODEL NUMBER IDENTIFICATION Nominal Capacity - 70 to 130
More informationInstallation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier
RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity
More informationInstallation and Operation Manual
Model 8120X Digital Ventilation Controller CODE MIN/ HR Installation and Operation Manual TABLE OF CONTENTS WARNINGS AND CAUTIONS Warnings and Cautions... 3 Package Contents... 4 Specifications.... 4 Mounting
More informationModel 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions
Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8140 FRESH AIR ILATOR MODEL 8140NC FRESH AIR ILATOR FILTER COVER ILATION CONTROLLER FILTER COVER ILATION TERMINALS
More informationINDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090
ENGINEERING DATA INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier Bulletin No. CCWH (08/2011) CCWH-065 CCWH-090 CCWH-135 ENERGY STAR Rating for CCWH-065 Model Only Nominal Capacity - 65
More informationSteam Humidifier Fan Pack Installation & Maintenance Instructions
850 Steam Humidifier Fan Pack 5658 Fan Pack Service Part Steam Humidifier Fan Pack Installation & Maintenance Instructions TABLE OF CONTENTS Safety Cautions...2 Materials List...3 Operation...3 Specifications
More informationRead and Save These Instructions
Quest 215 105, DryDual 155, 205 and 225 Dual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More informationQuest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest CDG Dry 74 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationOwner s Manual Phoenix 200HT
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 200HT Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 200HT is one of the most effective and versatile
More informationModel DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions
Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions Safety CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical
More informationOwner s Manual Phoenix 250 MAX
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 250 MAX Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 250 MAX is the latest LGR dehumidifier in the
More informationS1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS
Johnson ontrols Unitary Products S1-D065T01 entral Dehumidifier Installation Instructions WANING 1. 120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation.
More informationModel 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions
Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions MODEL 8142 FRESH AIR ILATOR MODEL 8142NC FRESH AIR ILATOR OUTLET COLLAR MOUNTING BRACKET ILATION CONTROLLER OUTLET COLLAR
More informationDRY 150 Quest PowerDry 1300
DRY 150 Quest PowerDry 1300 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate
More informationInstallation, Operation and Maintenance Instructions
Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction depends on
More information1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location
Therma-Stor Products A Division of DEC International Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 PHOENIX 300 Operation & Service Instructions Table of Contents 1. Specifications...
More informationPHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions
PHOENIX 200 MAX LOW GRAIN REFRIGERANT HIGH CAPACITY DEHUMIDIFIER Table of Contents Therma-Stor Products Box 8050 Madison, WI 53708 Toll Free 1-800-533-7533 Local 1-608-222-5301 Phoenix 200 Max Operation
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Commercial Series Refrigerated Kitchen Equipment Models CRA-FS CRA-HS CFA-FS CFA-HS A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71309 Issued: 7-1-011 CONTENTS
More informationREAD AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
Model DH70, DH90 & DH125 Dehumidifier Installation, Operation and Maintenance Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED This whole house dehumidifier can be used to control humidity
More informationModel 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual
Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual FILTER COVER VENTILATION CONTROLLER INLET COLLAR OUTLET COLLAR SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury
More informationInstallation & Operation Instructions
YEAR FULL WARRANTY PATENTS: D570,988 8,069,681 9,052,132 Patent Pending Dual-Air Distribution Installation & Operation Instructions The Max Dry Dual XT has a horizontal configuration and dual outlet design.
More informationSafety & Installation Instructions
Model 6303 & 6302 Zoned Comfort Control Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61001212A 6302-6303 Zoned Comfort Control Install.indd 1 TABLE OF CONTENTS SAFETY INSTRUCTIONS..........................................
More informationOwner s Manual Phoenix 250 MAX
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 250 MAX Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 250 MAX is the latest LGR dehumidifier in the
More information4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R175 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R175 is the first roto-mold LGR
More informationModel 1730A Compact Dehumidifier Installation Instructions
Model 1730A ompact Dehumidifier Installation Instructions WANING 1. 120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation. Leave power disconnected
More informationRead and Save These Instructions
Quest 215 506 DryDual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationDehumidifiers. Product Guide. Smaller. Quieter. Smarter.
Dehumidifiers Product Guide Smaller. Quieter. Smarter. Make dehumidification a larger part of your business. Many conditions can create humidity problems. In fact, humidity control is one of the most desired
More informationQuest 215 DryDual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions
Quest 215 DryDual Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationInstallation & Operation Instructions
I M PACT SERIES I MPACT 10 5 Installation & Operation Instructions Patent Pending Dual-Air Distribution Patents: D570,988 8,069,681 9,052,132 The Santa Fe Impact105 is the most energy Part Number efficient
More informationModel 8120 and 8126 Safety & Installation Instructions
Ventilation Controller Model 8120 and 8126 Safety & Installation Instructions FAMILIARIZE YOURSELF WITH THE INSTALLATION INSTRUCTIONS BEFORE STARTING DANGER ATTENTION INSTALLER: To prevent serious injury
More informationQuest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:
Quest DRY 90 180 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate satisfaction
More informationOwner s Manual HI-E Dry Vehere
Owner s Manual HI-E Dry Vehere Installation, Operation & Service Instructions Read and Save These Instructions HI-E-Dry Vehere Part Number 4025276 The HI-E DRY Vehere Pool & Spa Humidity Controller featuring
More informationParts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-340MAJ, MWJ hoshizakiamerica.com Number: 71389 Issued: 10-23-2017 Revised: 6-12-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationMcQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993
Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call
More informationQuest Dry Quest Dry 105, 155, and 205
Quest Dry Quest Dry 105, 155, and 205 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully.
More information4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R250 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R250 LGR Dehumidifier Coated Coils
More informationModel 65 Humidifier Control Owner s Manual
Model 65 Humidifier Control Model 65 Humidifier Control Owner s Manual Installed by: Installer Phone: Date Installed: PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER Thank you for purchasing the Aprilaire
More informationParts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com
Parts List Low-Profile Modular Crescent Cuber Models KML-325MAJ KML-325MWJ hoshizakiamerica.com Number: 71377 Issued: 4-7-2017 Revised: 9-8-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationParts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-515MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71390 Issued: 10-23-2017 Revised: 11-17-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL Patent Pending Dual-Air Distribution Designed for Basement and Crawlspace Dehumidification n High capacity n High efficiency n Environmentally friendly n Patent pending dual-air
More informationParts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-1100MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71392 Issued: 12-12-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationDaikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015
Replacement Parts List No. 700027600 Revision D 02/2015 Daikin McQuay Packaged Terminal Air Conditioner PGAN 007, 009, 012, 015 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationOwner s Manual Phoenix Arctic Max
420 Lien Rd Madison, WI 53704 Owner s Manual Phoenix Arctic Max Installation, Operation and Service Instructions Read and Save These Instructions The new Phoenix Arctic Max is the first portable air conditioner
More information4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R175 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R175 is the first roto-mold LGR
More informationOwner s Manual Phoenix R125 LGR Dehumidifier
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R125 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R125 is the first 65 pint LGR Dehumidifier.
More informationDaikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700028400 Revision A 07/207 Daikin McQuay Incremental PKEI, PKES, PKHS 07-09 Design 2 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
More informationSafety & Installation Instructions
8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location
More informationSafety & Installation Instructions
Model 6203 & 6202 Zoned Comfort Control Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61001213A 6202-6203 Zoned Comfort Control Install.indd 1 TABLE OF CONTENTS SAFETY INSTRUCTIONS..........................................
More information(EE1500, EE2000, EE2500, EE3000)
EE-Ti (EE1500, EE2000, EE2500, EE3000) Heat Pump (Mfg. 2010 Present) 15 26 3 11 12 1 BLUE WIRE RED WIRE YELLOW WIRE ORANGE WIRE These pressure switches are installed in the refrigerant line near the compressor
More informationDRY 150 Quest PowerDry 1300
DRY 150 Quest PowerDry 1300 Read and Save These Instructions This manual is provided to acquaint you with the dehumidifier so that installation, operation and maintenance can proceed successfully. Ultimate
More informationSafety & Installation Instructions
8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652A 8400 Tstat Install.indd 1 7/23/09 2:20:45 PM Table of contents Installation Installation location recommendations...
More informationSafety & Installation Instructions
Model 8476 Thermostat with Event-Based Air Cleaning Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 3 Outdoor
More informationParts List. Low-Profile Modular Crescent Cuber. Models KML-500MAJ KML-500MWJ. hoshizakiamerica.com
Parts List Low-Profile Modular Crescent Cuber Models KML-500MAJ KML-500MWJ hoshizakiamerica.com Number: 71378 Issued: -8-017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationOwner s Manual Phoenix 200 MAX
PO Box 8680 Madison, WI 53708 Phoenix 200 MAX TS-262C Owner s Manual Phoenix 200 MAX Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 200 MAX is one of the most
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER n Energy Star efficient n High capacity effective dehumidification: up to 65 pints of water a day n MERV-11 filtration standard;
More informationInstallation, Operating and Maintenance Manual
Installation, Operating and Maintenance Manual Model: DH-130A Table of Contents Safety................... 2 Specifications.................. 3 Operation................... 3 Installation..................
More information4201 Lien Rd. Madison, WI Owner s Manual Phoenix R200 LGR Dehumidifier. Installation, Operation & Service Instructions
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix R200 LGR Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix R200 is a compact, energy efficient
More informationInstallation & Operation Instructions
ADVANCE SERIES ADVANCE120 Installation & Operation Instructions Patent Pending Dual-Air Distribution The Santa Fe Advance120 has a horizontal configuration and unique dual airflow outlets that make it
More informationInstallation & Operation Instructions
YEAR FULL WARRANTY Patent Pending Dual-Air Distribution Installation & Operation Instructions The Santa Fe Advance2 has a horizontal configuration and unique dual airflow outlets that make it an ideal
More informationInstallation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)
Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics RNC Series Models RNC95 RNC155 RNC200 RNC10 RNC20 RNC120D RNC5-TPD Residential Heat Recovery Ventilators (HRV) Manufactured
More informationModel 75 Dehumidifier Control Owner s Manual
Model 75 Dehumidifier Control Model 75 Dehumidifier Control Owner s Manual Installed by: Installer Phone: Date Installed: PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER Thank you for your purchase of the
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationDSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!
DEHUMIDIFIERS GENERAL INFORMATION EXPLODED VIEWS PARTS LISTS DSR SERIES DSR-20 DSR-12 ENGLISH ATTENTION! There is a time delay on all units fitted with DFC 1 Controller. When starting or re starting the
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationShelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016
Shelleybasic Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 0 Contents Condensing Unit Assembly, / HP, Ra... Condensing Unit Assembly, / HP, R0a... Condensing
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WALL-MOUNTED SASO CERTIFIED AIR CONDITIONER Models: KA-N KA-N K0A-N General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual
More informationInstallation & Operation Instructions
COMPACT SERIES COMPACT70 Installation & Operation Instructions 230V / 50HZ The Santa Fe Compact70 is designed for superior basement and crawl space dehumidification. Tight spaces are no problem for the
More informationMcQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017
Replacement s List 055208000 Revision E 08/207 McQuay Incremental MQS 007-05 Vintages A 02-05 Vintage B Last Manufactured: 993 To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationMcQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018
Replacement Parts List No. 70006800 Revision D 03/208 McQuay Enfinity Vertical Water Source Heat Pump WFCV, WFCW 007-02 Design To find your Daikin Applied parts distributor, call -800-377-2787 or visit
More informationSteam Humidification Light Commercial Applications. Better technology means better business.
Steam Humidification Light Commercial Applications Better technology means better business. Aprilaire Steam Humidifiers are built to last. Through extensive research and over 50 years expertise in humidification
More informationREPLACEMENT PARTS LIST O4 Series Oil Furnace
R REPLACEMENT PARTS LIST O4 Series Oil Furnace Low Boy High Boy Downflow/Horizontal shown with optional front vestibule Model O4HD 2 Model O4HD Horizontal Oil Furnaces O4HD O4HD ITEM DESCRIPTION 091A-12F
More informationMcQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017
Replacement Parts List No. 700016700 Revision A 07/2017 McQuay Console Water Source Heat Pump WWDU 07-15 Design A Last Manufactured: 2005 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationOwner s Manual Ultimate 340
The World Leader in Carpet Cleaning, Restoration and Janitorial Supplies 1.800.400.9473 Owner s Manual Ultimate 340 Installation, Operation & Service Instructions Read and Save These Instructions The Ultimate
More informationINSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER n Energy Star efficient n High capacity effective dehumidification: up to 70 pints of water a day n MERV-11 filtration standard;
More informationOwner s Manual AF365
The World Leader in Carpet Cleaning, Restoration and Janitorial Supplies 1.800.556-6366 Owner s Manual AF365 Installation, Operation & Service Instructions Read and Save These Instructions The AF365 is
More informationDaikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017
Replacement Parts List No. 700053300 New 11/2017 Daikin Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit
More information