Product Data. 24ANB1 Infinityr Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

Size: px
Start display at page:

Download "Product Data. 24ANB1 Infinityr Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons"

Transcription

1 Infinityr Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons Carrier s Air Conditioners with Puronr refrigerant providea collection of features unmatched by any other family of equipment. The has been designed utilizing Carrier s Puron refrigerant. The environmentally sound refrigerant allows youtomakearesponsibledecisionintheprotectionoftheearth s ozonelayer. This product has been designed and manufactured to meet Energy Starr criteria for energy efficiency when matched with appropriatecoilcomponents. Refertothecombinationratingsin theproductdataforsystemcombinationsthatmeetenergystarr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory ( for the most up-to-date ratings information. Product Data INDUSTRYLEADING FEATURES/BENEFITS Efficiency S SEER/ EER S MicrotubeTechnologyt refrigeration system S Indoor air quality accessories available Sound S Soundlevelaslowas65dBA S Quietmountsplitpostcompressorgrommets S ElectronicECMballbearingoutdoorcondenserfan motor S Forward-sweptcondenserfanblade S Compressorsoundhood S Laminated steel compressor mounting plate Comfort S SystemsupportsInfinitytControlorstandard2-stage thermostat controls Reliability S Puronrrefrigerant - environmentallysound,won t depletetheozonelayerandlowlifetimeservicecost. S Front-seating service valves S 2-stage scroll compressor S Internal pressure relief valve S Internal thermal overload S Low pressure switch S High pressure switch S Filter drier S Crankcase heater standard S Balanced refrigeration system for maximum reliability ControlsandDiagnostics S Infinitytcontrol or2-stagethermostat S TwocontrolwirestooutdoorunitwithInfinityControl (serialnumbers1213eandnewer) S Utility Interface Connection S Enhanced diagnosticscapability with Infinity Control Durability WeatherArmor Ultrat protection package: S Solid, Durable sheet metal construction S Steellouvercoilguard S Baked-on,completeoutercoverage, powderpaint Applications S Long-line - upto250feet(76.2m)totalequivalent length,upto200feet(60.96m)condenserabove evaporator,orupto80ft.(24.38m)evaporatorabove condenser(seelonglineguideformoreinformation.) S Low ambient(down to 0_F) with complete Infinity system.

2 MODELNUMBERNOMENCLATURE N N A A A/N N N N A/N A/N A/N N N 2 4 A N B A Product Series Product Family Tier 24=AC A=RESAC N= Infinity Major SEER Cooling Series Capacity B=Puron 1=21 SEER Nominal Variations Open Open Voltage Minor Series 3= ,1,2... A=Standard 0=Not Defined 0=Not Defined the environmentally sound refrigerant Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to This product has been designed and manufactured to meetenergystar criteriaforenergyefficiencywhen matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical toachieveratedcapacityandefficiency. Installationof thisproductshouldfollowallmanufacturingrefrigerant chargingandairflowinstructions. Failuretoconfirm properchargeandairflowmayreduceenergy efficiencyandshortenequipmentlife. FEATURES STANDARDFEATURES UnitSize---Voltage,Series Puron Refrigerant X X X X MaximumSEERRating* Stage Scroll Compressor X X X X 2 control wires to outdoor unit with Infinity Control (serial numbers 1213E and newer) X X X X Crankcase Heater X X X X LowAmbientCapabilityto0_F( _C) w/infinity Control X X X X Enhanced Diagnostics w/infinity Control X X X X Utility Interface Connection X X X X Louvered Coil Guard X X X X FieldInstalledFilterDrier X X X X Front Seating Service Valves X X X X Internal Pressure Relief Valve X X X X Internal Thermal Overload X X X X LongLineCapability X X X X Low Pressure Switch X X X X High Pressure Switch X X X X Sound Blanket X X X X X=Standard * With approved combinations 2

3 REFRIGERANTPIPINGLENGTHLIMITATIONS LiquidLineSizingandMaximumTotalEquivalentLengths { forcoolingonlysystemswithpuronrrefrigerant: Themaximumallowablelengthofaresidential splitsystem dependson theliquid linediameter andvertical separationbetween indoorand outdoorunits. SeeTablebelowforliquidlinesizingandmaximumlengths: Size 024 AC with Puron LiquidLine Connection 3/8 Liquid Line Diam. w/txv ( ) MaximumTotalEquivalentLength OutdoorUnitBELOWIndoorUnit AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor Vertical Separation ft(m) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) 1/ /16 250* 250* 250* 250* 250* 225* /8 250* 250* 250* 250* 250* 250* 250* 250* 250* 036 5/ AC with 3/8 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* Puron 060 AC with Puron 3/8 3/8 250* 250* 250* 225* * Maximumactuallengthnottoexceed200ft(61m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details =outsideacceptablerange Size 024 AC with Puron LiquidLine Connection 3/8 Liquid Line Diam. w/txv 25 (7.6) MaximumTotalEquivalentLength OutdoorUnitABOVEIndoorUnit AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor Vertical Separation ft(m) ( ) ( ) ( ) ( ) ( ) ( ) ( ) 1/ * 250* 250* 250* 5/16 250* 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 225* 250* 250* 250* 250* 250* 250* 250* AC with 3/8 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron 060 AC with Puron 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* *Maximumactuallengthnottoexceed200ft(61m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. Liquid Line Size 3/8 REFRIGERANTCHARGEADJUSTMENTS Puron Charge oz/ft(g/m) 0.60(17.74) (Factorychargeforlineset=9oz/266.16g) 5/ (11.83) 1/4 0.27(7.98) Unitsarefactorychargedfor15ft(4.6m)of3/8 liquidline. Thefactorychargefor3/8 lineset9oz.(266.16g). Whenusingotherlength ordiameterliquidlines,chargeadjustmentsarerequiredperthechartabove. ChargingFormula: [(Linesetoz/ftxtotallength) (factorychargeforlineset)]=chargeadjustment Example1:System has 15 ft of line set using existing 1/4 liquid line. What charge adjustment is required? Formula: (.27oz/ftx15ft) (9oz)=(-4.95)oz. Netresultistoremove4.95ozofrefrigerantfromthesystem Example2: Systemhas45ftofexisting5/16 liquidline.whatisthechargeadjustment? Formula: (.40oz/ft.x45ft) (9oz.)=9oz. Netresultistoadd9ozofrefrigeranttothesystem 3

4 LONGLINEAPPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line dependsontheliquidlinediameter,actuallengthofthetubing,andverticalseparationbetweentheindoorandoutdoorunits. ForAirConditionersystems,thechartbelowshowswhenanapplicationisconsideredLongLine. ACWITHPURONrREFRIGERANTLONGLINEDESCRIPTIONft(m) Beyondtheselengths,longlineaccessoriesarerequired LiquidLineSize UnitsOnSameLevel OutdoorBelowIndoor OutdoorAboveIndoor Noaccessoriesneededwithinallowed Noaccessoriesneededwithinallowed 1/4 175(53.3) lengths lengths 5/16 120(36.6) 50(15.2)verticalor120(36.6)total 120(36.6) 3/8 80(24.4) 35(10.7)verticalor8024.4)total 80(24.4) Note: SeeLongLineGuidelinefordetails VAPORLINESIZINGANDCOOLINGCAPACITYLOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses Puronr Refrigerant 2-Stage Air Conditioner Applications Unit Nominal Size(Btuh) Stage Puron AC Stage Puron AC Maximum Liquid Line Diameters (In.OD) 3/8 3/8 Vapor Line Diameters (In.)OD ( ) ( ) ( ) CoolingCapacityLoss(%) TotalEquivalentLineLengthft.(m) ( ) ( ) ( ) ( ) ( ) ( ) 5/ / / / / / Stage Puron 3/8 7/ AC 1---1/ / Stage 3/8 7/ Puron AC 1---1/ Applicationsinthisareamaybelonglineandmayhaveheightrestrictions. SeetheResidentialPipingandLongLineGuideline. Applications in this area are not recommended due to insufficient oil return PHYSICALDATA UNITSIZE---VOLTAGE,SERIES OperatingWeightlb(kg) 282(127.9) 312(141.5) 335(152.0) 336(152.4) ShippingWeightlb(kg) 324(147.0) 357(161.9) 381(172.8) 381(172.8) CompressorType 2---StageScroll REFRIGERANT Puron (R---410A) Control TXV(PuronHardShutoff) Chargelb.(kg) 13.34(6.05) 13.66(6.20) 13.53(6.14) 14.33(6.50) CONDFAN ForwardSweptPropellerType,DirectDrive Air Discharge Vertical Air Qty(CFM) 3040/ / / /4668 Motor HP 1/5 1/5 1/5 1/5 Motor RPM 628/ / / /828 CONDCOIL Face Area(sq. ft.) FinsperIn Rows Circuits VALVECONNECT.(In.ID) Vapor 7/8 7/8 7/8 7/8 Liquid 3/8 REFRIGERANTTUBES*(In.OD) Vapor( Ft Tube Length) 7/8 7/ / /8 Liquid( Ft Tube Length) 3/8 *Unitsareratedwith25ft(7.6m)oflinesetlength. SeeVaporLineSizingandCoolingCapacityLosstablewhenusingothersizesandlengthsoflineset. 4

5 ELECTRICALDATA UnitSize--- Voltage, Series V/PH OPERVOLTS* COMPR FAN MCA MIN WIRE SIZE{ MIN WIRE SIZE{ MAX LENGTH ft.(m)} MAX LENGTH ft.(m)} MAX FUSE**or CKTBRK AMPS MIN MAX LRA RLA FLA 60 C 75 C 60 C 75 C (15.2) 48(14.6) (18.0) 56(17.1) / (20.7) 65(19.8) (24.4) 76(23.2) 60 * Permissible limits of the voltage range at which the unit will operate satisfactorily { Ifwireisappliedatambientgreaterthan30_C,consulttable oftheNEC(NFPA70). Theampacityofnon---metallic---sheathedcable(NM),trade nameromex,shallbethatof60_c conditions,perthenec(nfpa70)article ifotherthanuncoated(no---plated),60or75_c insulation,copper wire(solidwirefor10awgorsmaller,strandedwireforlargerthan10awg)isused,consultapplicable tablesofthenec(nfpa70). } Lengthshownisasmeasuredonewayalongwirepathbetweenunitandservicepanelforvoltagedropnottoexceed2%. **Time---Delayfuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA ---RatedLoadAmps NOTE:Controlcircuitis24---Vonallunitsandrequiresexternalpowersource. Copperwiremustbeusedfromservicedisconnecttounit. Allmotors/compressorscontaininternaloverloadprotection. Complieswith2010requirementsofASHRAEStandards90.1 A-WEIGHTEDSOUNDPOWER(dBA) UnitSize--- Voltage,Series Standard Rating (dba) TypicalOctaveBandSpectrum(dBA,withouttoneadjustment) HighStage LowStage HighStage LowStage HighStage LowStage HighStage LowStage NOTE:TestedinaccordancewithAHRIStandard (NotlistedwithAHRI). CHARGINGSUBCOOLING(TXV-TYPEEXPANSIONDEVICE) UNIT SIZE---VOLTAGE, SERIES REQUIRED SUBCOOLING_F(_C) (5.6) (6.1) (6.7) (7.8) ACCESSORYCONTROLS PART NUMBER SYSTXCCITN01 SYSTXCCITW01 SYSTXCC4ZC01 SYSTXCCSMS01 SYSTXCCRRS01 SYSTXCCRCT01or SYSTXCCRWF01 SYSTXCCNIM01 InfinityTouchControl(non---Wi---Fi) Infinity Touch Control with Wi---Fi& Wireless Access Point DESCRIPTION Infinity4---ZoneDamperControlModule(Wall---mountedcontrolforafour---zonesystem.) InfinitySmartSensor(Optionalwallcontrolusedtomonitortemperatureand/orfancontrolinanindividualzone.) InfinityRemoteRoomSensor(Monitorstemperatureinanindividualzone.) Infinity System Remote Access Module(Hardware for wireless access and control via internet.) InfinityNetworkInterfaceModule(ConnectsHeatRecoveryandEnergyRecoveryVentilators onnon---zoningapplications.) 5

6 ACCESSORIES ORDER NUMBER DESCRIPTION KAALS0201LLS LIQUIDLINESOLENOIDVALVEKIT X X X X KSAHS2501AAA* HARDSTARTKIT X X KSAHS2801AAA* HARDSTARTKIT X X KSASF0101AAA SUPPORT FEET X X X X x=accessory * Not backward compatible to previous series ACCESSORYUSAGEGUIDELINE ACCESSORY REQUIREDFOR LOW---AMBIENT COOLING APPLICATIONS (Below55 F/12.8_C) REQUIREDFORLONGLINE APPLICATIONS* REQUIREDFORSEACOAST APPLICATIONS (Within 2 miles/3.22 km) CompressorStartAssistKit No No No Crankcase Heater Yes Yes (standardonsomeunits) (standardonsomeunits) No Evaporator Freeze Protection Standard with Infinity Control No No Liquid---LineSolenoidValve No No No Low---AmbientControl Standard with Infinity Control No No Puron Refrigerant Balance Port Hard--- ShutOff TXV Yes{ Yes{ Yes{ SupportFeet Recommended No Recommended WinterStartControl Standard with Infinity Control No No * Fortubingsetlengthsbetween80and200ft.(24.38and60.96m)horizontalor35ft.(10.7m)verticaldifferential(totalequivalentlength),refertotheLong LineGuideline AirConditionersandHeatPumpsusingPuron Refrigerant. { Requiredonallindoorunits.StandardonallnewPuronrefrigerantfancoilsandfurnacecoils. Accessory Description and Usage(Listed Alphabetically) 1. Compressor Start Assist - Capacitor and Relay 3.SupportFeet Start capacitor and relay gives a hard boost to compressor motorateachstartup. UsageGuideline: Notrequired onthisunitsincecompressoralwaysstarts unloaded. Availableifrequiredbylocalcodes. 2.CrankcaseHeater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chanceofliquidslugging. UsageGuideline: Requiredinlowambientcoolingapplications. Requiredinlonglineapplications. Suggestedinallcommercialapplications. Four stick-on plastic feet that raise the unit 4 in. (101.6 mm) abovethemounting pad.this allowssand, dirt,and otherdebris tobeflushedfromtheunitbase,minimizingcorrosion. UsageGuideline: Suggestedinthefollowingapplications: Coastal installations. Windyareasorwheredebrisisnormallycirculating. Rooftop installations. Forimprovedsoundratings. 4.ThermostaticExpansionValve(TXV) Amodulatingflow-controlvalvewhichmetersrefrigerantliquid flow rate into the evaporator in response to the superheat of the refrigerantgasleavingtheevaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hardshutofftypesareavailable. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. UsageGuideline: RequiredtoachieveAHRIratingsincertainequipment combinations. Refer to combination ratings. HardshutoffTXVorLLSrequiredinairconditioner long line applications. 6

7 DIMENSIONS - ENGLISH 7

8 DIMENSIONS - SI 8

9 CLEARANCES Clearances (various examples) Wall Wall 24 Service 6 (152.4 mm) 12 (304.8) 24 (609.6) Service Wall 6 (152.4) 12 (304.8) 12 (304.8) 12 (304.8) Wall 24 (609.6) Service 24 (609.6) Service 24 (609.6) Service A (609.6) 24 (609.6) 24 (609.6) Note: Numbers in ( ) = mm IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re-circulation of discharge air. 9

10 TESTED AHRI COMBINATION RATINGS* NOTE: Ratingscontainedinthisdocumentaresubjecttochangeatanytime. ForAHRIratingscertificates,pleaserefertotheAHRIdirectorywww.ahridirectory.org AdditionalratingsandsystemcombinationscanbeaccessedviatheCarrierdatabaseat: For performance data at specific application&/or design conditions with various indoor unit combinations, the equipment performancecalculatorcanbeaccessedat: AHRISTANDARDRATINGS---COOLING Model Number INDOOR MODEL CAPACITY IDCFM SEER EER HIGH LOW HIGH LOW 24A**31 FE5ANB A**31 FE5ANB A**31 FE4ANB A**31 FE4ANB * AHRI=AirConditioning,Heating&RefrigerationInstitute EER Energy Efficiency Ratio--- 80_F(26.6_C) indoor db/67_f(19.4_c) indoor wb& 95_F(35_C) outdoor wb. SEER SeasonalEnergyEfficiencyRatio TDR Time---DelayRelay. Inmostcases,only1methodshouldbeusedtoachieveTDRfunction.Usingmorethan1methodinasystemmaycausedegradationinperformance. UseeithertheaccessoryTime---DelayRelayKAATD0101TDRorafurnaceequippedwithTDR.MostCarrierfurnacesareequippedwithTDR. UI UserInterface NOTES: 1.Ratingsarenetvaluesreflectingtheeffectsofcirculatingfanmotorheat.Supplementalelectricheatisnotincluded. 2.Testedoutdoor/indoorcombinationshavebeentestedinaccordancewithDOEtestproceduresforcentralairconditioners.RatingsforothercombinationsaredeterminedunderDOE computersimulationprocedures. 3.DetermineactualCFMvaluesobtainableforyoursystembyreferringtofanperformancedatainfancoilorfurnacecoilliterature. 4. Do not apply with capillary tube coils as performance and reliability are affected. 10

11 DETAILEDCOOLINGCAPACITIES# EVAPORATORAIR CFM EWB F( C) CONDENSER ENTERING AIR TEMPERATURES F( C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 24A**31 Outdoor Section With FE5ANB004 Indoor Section--- High 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) A**31 Outdoor Section With FE5ANB004 Indoor Section--- Low 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) Seenotesonpage14 11

12 DETAILEDCOOLINGCAPACITIES#(CONTINUED) EVAPORATORAIR CFM EWB F( C) CONDENSER ENTERING AIR TEMPERATURES F( C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 36A**31 Outdoor Section With FE5ANB004 Indoor Section--- High 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) A**31 Outdoor Section With FE5ANB004 Indoor Section--- Low 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) Seenotesonpage14 12

13 DETAILEDCOOLINGCAPACITIES#(CONTINUED) EVAPORATORAIR CFM EWB F( C) CONDENSER ENTERING AIR TEMPERATURES F( C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 48A**31 Outdoor Section With FE4ANB006 Indoor Section--- High 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) A**31 Outdoor Section With FE4ANB006 Indoor Section--- Low 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) Seenotesonpage14 13

14 DETAILEDCOOLINGCAPACITIES#(CONTINUED) EVAPORATORAIR CFM EWB F( C) CONDENSER ENTERING AIR TEMPERATURES F( C) 75(23.9) 85(29.4) 95(35) 105(40.6) 115(46.1) 125(51.7) Total Sens Total Sens Total Sens Total Sens Total Sens Total Sens 60A**31 Outdoor Section With FE4ANB006 Indoor Section--- High 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) A**31 Outdoor Section With FE4ANB006 Indoor Section--- Low 57(13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) (13.9) (16.7) (17.2) (19.4) (22.2) {Totalandsensiblecapacitiesarenetcapacities.Blowermotorheathasbeensubtracted. } Sensible capacities shown are based on 80_F(27_C)entering air at the indoor coil.for sensible capacities at other than 80_F(27_C),deduct 835 Btuh (245kW)per1000CFM(480L/S)ofindoorcoilairforeachdegreebelow80_F(27_C),oradd835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairperdegreeabove80_F(27_C). #DetailedcoolingcapacitiesarebasedonindoorandoutdoorunitatthesameelevationperAHRIstandard210/ Ifadditionaltubinglengthand/orindoorunitislocatedaboveoutdoorunit,aslightvariationincapacity may occur. **Systemkwistotalofindoorandoutdoorunitkilowatts. EWB EnteringWetBulb NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. 14

15 CONDENSER ONLY RATINGS* SST F( C) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) Seenotesonpage17 CONDENSERENTERINGAIRTEMPERATURES F( C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 24A**31---High TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW A**31---Low TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW A**31---High TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

16 CONDENSER ONLY RATINGS* CONTINUED SST F( C) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) Seenotesonpage17 CONDENSERENTERINGAIRTEMPERATURES F( C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 36A**31---Low TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW A**31---High TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW A**31---Low TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

17 CONDENSER ONLY RATINGS* CONTINUED SST F( C) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) 30 ( ) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 60 (15.56) CONDENSERENTERINGAIRTEMPERATURES F( C) 55(12.78) 65(18.33) 75(23.89) 85(29.44) 95(35.0) 105(40.56) 115(46.11) 125(51.67) 60A**31---High TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW A**31---Low TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW * AHRI listing applies only to systems shown in Combination Ratings table. KW --- Outdoor Unit Kilowatts Only. SDT --- Saturated Temperature Leaving Compressor( F) SST --- SaturatedTemperatureEnteringCompressor( F/ C) TCG --- GrossCoolingCapacity(1000Btuh) 17

18 GUIDE SPECIFICATIONS GENERAL SystemDescription Outdoor-mounted, air-cooled, split-system air conditioner unit suitableforgroundorrooftopinstallation.unitconsistsofahermetic compressor,anair-cooledcoil,propeller-typecondenserfan,anda control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match uptoapackagedfancoilorcoilunit. QualityAssurance Unitwillberatedin accordancewith thelatesteditionof AHRIStandard210. Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. Unit construction will comply with latest edition of ANSI/ASHRAEandwithNEC. Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit willhavec-ulapproval. UnitcabinetwillbecapableofwithstandingFederalTest Method Standard No. 141 (Method 6061) 500-hr salt spray test. Air-cooled condenser coils will be leak tested and pressure tested. UnitconstructedinISO9001approvedfacility. Delivery,Storage,andHandling Unitwillbeshippedassinglepackageonlyandisstored andhandledperunitmanufacturer srecommendations. Warranty(forinclusionbyspecifyingengineer) U.S.andCanadaonly. PRODUCTS Equipment Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr(R-410A),and special features required prior to field start-up. UnitCabinet Unit cabinet, including louvered coil guard, will be constructed of galvanized steel, bonderized, and coated withapowdercoatpaint. Fans Condenser fan will be direct-drive propeller type, dischargingairupward. AIR-COOLED,SPLIT-SYSTEMAIRCONDITIONER 2TO5NOMINALTONS Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings.shaftswillbecorrosionresistant. Fanbladeswillbestaticallyanddynamicallybalanced. Condenser fan openings will be equipped with coated steel wire safety guards. Compressor Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. CondenserCoil Condensercoilwillbeaircooled. Coil will be constructed of aluminum finsmechanically bonded to copper tubes which are then cleaned, dehydrated,andsealed. RefrigerationComponents Refrigerationcircuitcomponentswillincludeliquid-line shutoffvalvewithsweatconnections, vapor-lineshutoff valve with sweat connections, system charge of Puronr (R-410A)refrigerant,andcompressoroil. Unit will be equipped with high-pressure switch, low pressure switch and filter drier for Puron refrigerant. OperatingCharacteristics Thecapacity oftheunitwillmeetorexceed Btuh at a suction temperature of F/_C. The power consumptionatfullloadwillnotexceed kw. Combination of the unit and the evaporator or fan coil unitwillhaveatotalnetcoolingcapacityof Btuh or greater at conditions of CFM entering air temperature at the evaporator at F/_C wet bulb and F/_C dry bulb, and air entering the unit at F/_C. The system will have a SEER of Btuh/watt or greater at DOE conditions. ElectricalRequirements Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactoryoperationwithinvoltagelimitsof vto v. Unitelectricalpowerwillbesinglepointconnection. Controlcircuitwillbe24v. SpecialFeatures Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 18

Product Data. 24ANB6 Infinityr Air Conditioner with Puronr Refrigerant 1---1/2 to 5 Nominal Tons(Size )

Product Data. 24ANB6 Infinityr Air Conditioner with Puronr Refrigerant 1---1/2 to 5 Nominal Tons(Size ) Infinityr Air Conditioner with r Refrigerant 1---1/2 to 5 Nominal Tons(Size 18---60) Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS Infinityr 19 2 --- Stage Heat Pump with Puronr Refrigerant 2to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound 24VNA0 Infinityr Variable Speed Air Conditioner with Greenspeedr Intelligence 2to5NominalTons Product Data Carrier s 24VNA0 with Greenspeed R Intelligence is a variable speed cooling product providing

More information

Advance Product Data

Advance Product Data Infinityr 19VS Variable Speed Air Conditioner 2, 3, and 4---Ton (5---Ton Coming Q4 2014) Advance Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably

More information

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24AHA4 Performance Series Air Conditioner with Refrigerant 1-1/2 to 5 Nominal Tons Product Data Carrier air conditioners with refrigerant provide a collection of features unmatched by any other family

More information

Product Data. 24ACC6 Performancet16 Air Conditioner with Puronr Refrigerant 1---1/2 to 5 Tons

Product Data. 24ACC6 Performancet16 Air Conditioner with Puronr Refrigerant 1---1/2 to 5 Tons Performancet16 Air Conditioner with r Refrigerant 1---1/2 to 5 Tons Product Data the environmentally sound refrigerant Carrier s Air Conditioners with r refrigerant providea collection of features unmatched

More information

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS. Performancet 16 2 --- Stage Heat Pump with Puronr Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with Puron r refrigerant provide a collection of features

More information

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton PRODUCT NUMBER NOMENCLATURE 14 SEER Air Conditioner with Refrigerant PA14 N C 018 00G B A Series Variations Electrical Supply N 208/230 60 1 00G Variations C Nominal Capacity 018 1 1/2Ton 024 2Tons 030

More information

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS 24ABC6 Comfortt16 Air Conditioner with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt,

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS Product Data Bryant Air Conditioners with refrigerant provide a collection of features unmatched by any other

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons 116B Legacyt Line 16 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 114CNC Legacyt Line Air Conditioner for Coastal Applications with r Refrigerant 1--1/2 To 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14.0 SEER / 11.0 13.5 EER S Microtube

More information

Advance Product Data

Advance Product Data EVOLUTION R V VARIABLE SPEED AIR CONDITIONER WITH PURONr REFRIGERANT 2, 3, AND 4-TON (5-TON COMING Q4 2014) Advance Product Data The Evolution V air conditioner offers high -efficiency variable speed performance

More information

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230

More information

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS Product Data Bryant Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S S S S Comfort S

Product Data. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S S S S Comfort S 187B (2-5 Ton) EVOLUTIONr AIR CONDITIONER WITH PURONr REFRIGERANT Product Data Bryant s air conditioners with r refrigerant provide a collection of features unmatched by any other family of equipment.

More information

A 14 SEER Heat Pump with R---410A Refrigerant Series

A 14 SEER Heat Pump with R---410A Refrigerant Series MODEL NUMBER NOMENCLATURE PH14 N B 018 00G B A 14 SEER Heat Pump with R---410A Refrigerant Series Electrical Supply N=208/230---1 P=208/230---3 E=460/3 B R---410A Nominal Capacity 018 1 1/2Tons 024 2Tons

More information

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t Infinityr 15 Heat Pump with Puronr Refrigerant 2to4NominalTons(Sizes24---48) Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. CA13NA 018 060 Base Series Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s non -ozone depleting refrigerant. INDUSTRY LEADING FEATURES / BENEFITS Efficiency

More information

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability 25HPB6 Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Tons Product Data the environmentally sound refrigerant Carrier heat pumps with Puronr refrigerant provide a collection of features

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S BH13NA 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH13 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4**C Comfort 14 Heat Pump for Coastal Applications with r Refrigerant 1---1/5 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5 -- 11.7 EER / 8.2 HSPF

More information

Product Data. Efficiency. S S Reliability

Product Data. Efficiency. S S Reliability 018-060 SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT Product Data Bryant s BH14 has been designed utilizing Bryant s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with r refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCD

More information

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet 2---tage Air Conditioner with r Refrigerant 2to5Tons Product Data the environmentally sound refrigerant Carrier Air Conditioners with r refrigerant provide a collection of features unmatched

More information

N4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors

More information

Product Data. Efficiency

Product Data. Efficiency BH14NB SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.5-11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration

More information

Advance Product Data

Advance Product Data EVOLUTION R EXTREME VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT (2-5 Ton) Advance Product Data Bryant s Evolutionr Extreme is a breakthrough product providing up to 13 HSPF heating efficiency and

More information

WCH5**4. Product Specifications

WCH5**4. Product Specifications HEAT PUMP HIGH EFFICIENCY 15 SEER 1-1/2 THRU 5 TONS SPLIT SYSTEM ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 208 / 230 Volt, 1- phase, 60 Hz This product has been designed and manufactured to meet ENERGY

More information

Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS 24ACB7 Performancet 17 2---tage Air Conditioner with r Refrigerant 2to5Tons Product Data Carrier Air Conditioners with r refrigerant provide a collection of features unmatched by any other family of equipment.

More information

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES: 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons Product Data The 50 Hertz Outdoor Sections of Split-System Heat Pumps are designed for quiet, reliable heating during the winter

More information

Product Data. Efficiency

Product Data. Efficiency Comfort 13 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched by

More information

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS Product Data 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 The 38CKS Air Conditioner is designed for superior performance durability in harsh environments. The product achieves

More information

Product Data. Efficiency

Product Data. Efficiency 25HCE4 Comfort 14 Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of

More information

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS Performancet Series Heat Pump with Puronr Refrigerant 1 --- 1/2 to 5 Nominal Tons Product Data the environmentally sound refrigerant Carrier Heat Pumps with Puronr refrigerant provide a collection of features

More information

Advance Product Data

Advance Product Data Comfort 14 Heat Pump with r Refrigerant 1 --- 1/2 to 5 Nominal Tons Advance Product Data the environmentally sound refrigerant Carrier heat pumps with r refrigerant provide a collection of features unmatched

More information

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS PA13NA PA13PA 13 SEER Split---System Air Conditioner With R---410A Refrigerant Single & Three Phase 1 --- 1/2 To 5 Tons Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from

More information

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES Product Data 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS Sizes 018 thru 060 Model 38CKC Energy-Efficient Air Conditioner incorporates innovative technology to provide reliable cooling performance.

More information

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S Baset13 Air Conditioner with Puronr Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other

More information

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES Product Data 38CKC 50 Hz Air Conditioner Sizes 018 thru 060 Model 38CKC 50 Hertz energyefficient air conditioner incorporates innovative technology to provide reliable summer cooling performance. Built

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

R 410A Ducted Horizontal Air Conditioner

R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS, 208/230

More information

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT SOUND REFRIGERANT ENVIRONMENTALLY PAJ4 Product Specifications UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R-410A

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126CNA PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126CNA PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS MODEL 126CNA PREFERRED ERIE AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. 018---060 Base eries Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS. (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1 --- 1/2 to 5 Nominal Tons) Product Data The Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS MODEL PREFERRED ERIE AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data the environmentally sound refrigerant Bryant Air Conditioners with r refrigerant provide a collection of

More information

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( ) (N,P)R SPLIT SYSTEM HEAT PUMP For Use With R --- 22 Refrigerant 1---1/2 TO 5 TONS (018 --- 060) Product Data *Units factory---shipped with no refrigerant. Dry nitrogen charge only. FEATURES AND BENEFITS

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127. Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing

More information

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES: (60 Hz) 13 SEER Air Conditioner Sizes 018 --- 060 Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

Product Data. 24AAA5 Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 24AAA5 Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS. 24AAA5 ingle---tage Air Conditioner with r Refrigerant 1 --- 1/2 To 5 Tons Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability 14.0 EER / 11.7 12.2 EER (based on tested combination)

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA ENVIRONMENTALLY SOUND REFRIGERANT HC4A3 Product Specifications R 410A Ducted Horizontal Air Conditioner ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230 Volt, 1 Phase 3 THRU 5 TONS,

More information

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38YCC 50 Hz Heat Pump Sizes 024 thru 060 The 38YCC 50 Hertz Outdoor s of Split-System Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. With

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

WCA3**4. Product Specifications

WCA3**4. Product Specifications AIR CONDITIONER EFFICIENT 13 SEER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz WCA3**4 Use of the AHRI Certified TM Mark indicates a anufacturer

More information

WJH4 Product Specifications

WJH4 Product Specifications UP TO 14.5 SEER, R 410A PACKAGE HEAT PUMP FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz Use of the AHRI Certified TM Mark indicates a

More information

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit A10165 This unit is a packaged air conditioner for manufactured

More information

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes ) Single---Packaged Air Conditioner tem With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes 024---060) Product Data Unit A10165 The unit is a packaged air conditioner for manufactured housing,

More information

INDUSTRY LEADING FEATURES 1-1/2 5 / BENEFITS

INDUSTRY LEADING FEATURES 1-1/2 5 / BENEFITS 114CNA Legacyt Line 14 Air Conditioner with r Refrigerant 1-1/2 to 5 Nominal Tons Product Data Bryant s Air Conditioners with r refrigerant provide a collection of features unmatched by any other family

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (Sizes )

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (Sizes ) 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (izes 018-060) Product Data Bryant s Air Conditioners with Puronr refrigerant provide a collection of features unmatched

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Product Data. Efficiency

Product Data. Efficiency PH16NC PLIT YTEM HEAT PUMP WITH R -410A REFRIGERANT 1-1/2 TO 5 NOMINAL TON Product Data This product has been designed and manufactured to meet Energy tarr criteria for energy efficiency when matched with

More information

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S.

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S. CA13NA 024 060 Base eries Air Conditioner with r Refrigerant Product Data Carrier s CA13 has been designed utilizing Carrier s refrigerant. The environmentally sound refrigerant allows you to make a responsible

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant, AVAILABLE SIZES: CERTIFICATION: Nominal sizes available from 018 through 060 to meet the needs of residential and light commercial applications. All models are listed with UL, c-ul, ARI, CEC, and CSA-

More information

Product Data. CA14NA Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. CA14NA Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS. CA14NA ingle---tage Air Conditioner with r Refrigerant 1 --- 1/2 To 5 Tons Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability 14.0 EER / 11.7 12.0 EER (based on tested combination)

More information

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data Unit PA3Z- B A10165 The PA3Z- B unit is a packaged air conditioner

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BA15NA SINGLE -STAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BA15NA SINGLE -STAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS. BA15NA INGLE -TAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TON Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability 14.0 EER / 11.7 13.5 EER (based on tested combination)

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

Product Data. CA16NW Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. CA16NW Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS CA16NW ingle---tage Air Conditioner with r Refrigerant 1 --- 1/2 To 5 Tons Product Data INDUTRY LEADING FEATURE / BENEFIT Efficiency Reliability Durability Up to 16.5 EER / 12.2 13.0 EER Microtube Technologyt

More information

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S Durability. WeatherArmort protection package: S S S

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S Durability. WeatherArmort protection package: S S S Comfortt13 Air Conditioner for Coastal Applications with r Refrigerant Product Data the environmentally sound refrigerant Carrier s Air Conditioners with r refrigerant provide a collection of features

More information

Product Data. Fig. 1 - Unit 50VG -A

Product Data. Fig. 1 - Unit 50VG -A 50VG---A Performancet 16 SEER 2---Stage Packaged Air Conditioner tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VG -A A09033 Single-Packaged

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product

More information

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons 0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can

More information

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES: AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS (018-060) Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal sizes are available from 018 through 060 to meet the needs of residential and light commercial

More information

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality

More information

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: ELECTRICAL RANGE: FAN MOTOR: CABINET: UNIT

More information

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Compact, Self-Contained unit that offer low installation cost plus dependable performance. 0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water

More information

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons (60Hz) Single-Package Air Conditioners 3-5 Nominal Tons Product Data The is a package air conditioner for manufactured housing, residential, and light commercial applications. The unit design is the result

More information

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Product Data 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060 Carrier s WeatherMaker 38TXA with Puron provides a completely unique collection of features which cannot be matched by

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( ) 13 SEER Single--Packaged Heat Pump tem with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons (024--060) Product Data Fig. 1 - Unit Single -Packaged Heat Pump Units with: S easy installation

More information

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN 4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF FORM NO. 4HP15L-100 (12/2018) COILS Omniguard total corrosion protection technology designed coil Enhanced

More information

16 SEER TWO-STAGE AIR CONDITIONERS

16 SEER TWO-STAGE AIR CONDITIONERS FORM NO. ATZ-210 Supersedes Form No. ATZ-210 16 SEER TWO-STAGE AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability

More information

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS Product Data 38BRC (60 Hz) Air Conditioner Sizes 024 thru 060 Model 38BRC Energy-Efficient Air Conditioner incorporates innovative technology to provide quiet, reliable cooling performance. Built into

More information

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES AVAILABLE Nominal sizes are available from 018 SIZES: through 060 to meet the needs of residential and light commercial applications. EFFICIENCY: CERTIFICATION: With SEER of at least 10.0 and HSPF of 6.8,

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES ) SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES 024-060) Product Data 024-048 Size 060 Size Fig. 1 - Unit Single -Packaged Heat Pump Units with:

More information