Condensing Units w/ Screw Compressors
|
|
- Michael Greer
- 6 years ago
- Views:
Transcription
1 w/ Compressors Overview Increased Reliability Fewer moving parts result in improved durability Semi-hermetic motor design eliminates shaft seal and coupling concerns Integral oil system provides improved lubrication performance Factory-equipped microprocessor control system guarantees safe, reliable system performance Floating tube condenser coil design minimizes potential for refrigerant leaks Reduced Costs of Ownership Product Description The screw compressor condensing unit is an important addition to the Heatcraft air-cooled condensing unit product family, featuring innovative compact screw compressors and advanced microprocessor controls. The unit is designed to provide increased system reliability, reduced installation and operation costs, as well as, improved product integrity in commercial and industrial refrigeration applications. More capacity per compressor reduces number of compressors on large projects Reduced installation time and cost savings Built-in features include soft starting, slide valve unloading and digital controls for minimized operating costs Improved Product Integrity Advanced digital controls and variable capacity capability maintain more precise temperature control Minimal temperature fluctuations result in maximum product integrity Advanced diagnostic, monitoring and data logging options allow for quick system recovery Nomenclature Number of Circuits S = Single D = Dual S S V 000B M 6 D Compressor Style Airflow Horsepower S = V = Vertical 050B = B = B = B = B = B = B = B = B = 140 Temperature Range M = Medium H = High Refrigerant type 6 = R-404A, R = R-407C Voltage D = 460/3/60 E = 575/3/60 1 Prices and specifications subject to change without notice. Rev. 03/15
2 w/ Compressors Configurable Models Pricing Bohn Model List Price by Motor Voltage ($US) 460/3/60 575/3/60 Model Type Medium Temperature SSV050BM* 113, ,720 Single Compressor SSV060BM* 136, ,090 Single Compressor SSV070BM* 150, ,400 Single Compressor SSV080BM* 162, ,130 Single Compressor SSV090BM* 183, ,335 Single Compressor SSV100BM7 199, ,435 Single Compressor SSV110BM* 215, ,535 Single Compressor SSV125BM* 233, ,265 Single Compressor SSV140BM* 254, ,490 Single Compressor DSV100BM* 226, ,440 Dual Compressor DSV120BM* 272, ,175 Dual Compressor DSV140BM* 300, ,800 Dual Compressor High Temperature SSV050BH7 134, ,120 Single Compressor SSV060BH7 161, ,150 Single Compressor SSV070BH7 180, ,185 Single Compressor SSV080BH7 197, ,075 Single Compressor SSV090BH7 212, ,305 Single Compressor SSV100BH7 240, ,035 Single Compressor Notes Rev. 03/15 Notes: = Voltage Code ( D = 475/3/60, E = 575/3/60) * = Refrigerant Type (6 = R-404A, 7 = R-407C) Prices and specifications subject to change without notice. 2
3 w/ Compressors Need Factory-Installed Options? Factory-Installed Options - Medium Temperature remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. List Price by Model Number ($US) Option Code Option Description SSV050BM* SSV060BM* SSV070BM* SSV080BM* SSV090BM* SSV100BM7 SSV110BM* SSV125BM* SSV140BM* DSV100BM* DSV120BM* DSV140BM* Coil Options CS.CPR Copper Fin Coil Call Factory CS.BRZ Bronz-Glow Coil Call Factory CS.PRO Coated Fin Coil 4,227 5,284 6,340 7,542 7,973 9,567 11,938 12,755 16,352 9,567 11,938 16,352 Mechanical Options REC.001 Low Ambient Kit 2,509 2,509 2,509 3,296 3,296 3,296 4,083 4,083 4,083 5,018 5,018 5,018 SUC.005 Replaceable Core Suctionline Filter 2,119 2,119 3,387 3,387 3,387 3,387 3,387 6,774 6,774 4,237 4,237 6,774 SUC.007 Suction Accumulator 3,950 3,950 7,200 7,200 7,200 7,200 12,375 12,375 12,375 7,900 7,900 14,400 Electrical Options MS.001 Variable Speed EC Motor 32,560 48,930 48,930 48,930 65,300 65,300 65,300 81,400 81,400 65,300 81,400 81,400 3 Notes: = Voltage Code ( D = 475/3/60, E = 575/3/60) * = Refrigerant Type (6 = R-404A, 7 = R-407C) Prices and specifications subject to change without notice. Rev. 03/15
4 w/ Compressors Need Factory-Installed Options? Factory-Installed Options - High Temperature remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. List Price by Model Number ($US) Option Code Option Description SSV050BH7 SSV060BH7 SSV070BH7 SSV080BH7 SSV090BH7 SSV100BH7 Coil Options CS.CPR Copper Fin Coil Call Factory CS.BRZ Bronz-Glow Coil Call Factory CS.PRO Coated Fin Coil 5,284 11,162 13,267 14,880 18,573 22,293 Mechanical Options REC.001 Low Ambient Kit 2,509 3,296 3,296 4,083 4,083 4,083 SUC.005 Replaceable Core Suctionline Filter 2,119 2,119 3,387 3,387 3,387 3,387 SUC.007 Suction Accumulator 3,950 3,950 7,200 7,200 7,200 7,200 Electrical Options MS.001 Variable Speed EC Motor 48,930 65,300 65,300 81,400 81,400 97,500 Notes: = Voltage Code ( D = 475/3/60, E = 575/3/60) Rev. 03/15 Prices and specifications subject to change without notice. 4
5 w/ Compressors Need an electric defrost kit? Factory-Installed Electric Defrost Options remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/ low temp applications with electric defrost evaporators. Option Code Description Models Used On Notes List Price Adder ($US) DFT Htr Cont DFT Htr Cont DFT Htr Cont DFT Htr Cont DFT Htr Cont DFT fan 8 Htr Cont DFT Fan 10 Htr Cont DFT Fan 12 Htr Cont All Single Compressor All Single Compressor All Single Compressor All Single Compressor All All Dual Compressor All Dual Compressor All Dual Compressor Includes (1) evaporator fan contactor and (2) defrost heater contactor fusing. 48 Amp max load per heater contactor. 40 Amp max load per Includes (1) evaporator fan contactor and (3) defrost heater contactors fusing. 48 Amp max load per heater contactor. 40 Amp max load per Includes (1) evaporator fan contactor and (4) defrost heater contactors fusing. 48 Amp max load per heater contactor. 40 Amp max load per Includes (1) evaporator fan contactor and (5) defrost heater contactors fusing. 48 Amp max load per heater contactor. 40 Amp max load per Includes (1) evaporator fan contactor and (6) defrost heater contactors fusing. 48 Amp max load per heater contactor. 40Amp max load per Includes (2) evaporator fan contactors and (8) defrost heater defrost heater fusing. 48 Amp max load per heater contactor. 40 Amp max load per Includes (2) evaporator fan contactors and (10) defrost heater defrost heater fusing. 48 Amp max load per heater contactor. 40 Amp max load per Includes (2) evaporator fan contactors and (12) defrost heater defrost heater fusing. 48 Amp max load per heater contactor. 40 Amp max load per 3,415 4,240 5,066 6,773 8,481 10,132 13,546 16,962 5 Prices and specifications subject to change without notice. Rev. 03/15
6 w/ Compressors Overview Cabinet & Construction Painted steel cabinet for superior strength and corrosion resistance Welded frame on all models for a robust and rigid product base All units feature the Floating Tube coil which eliminates tube sheet leaks Floating Tube coil design is featured on both oil-cooler and condenser Serviceability Product Description The Low Temperature with Compressors are designed to meet the needs of demanding commercial and industrial refrigeration applications, including Food Processing and Cold Storage Warehousing. The units are engineered to be flexiblein custom design and constructed to meet the requirements of refrigeration contractors, consulting engineers and facility owners/operators. Certifications Manual pumpdown switch on all units Convenient access panels to easily service internal components Replaceable core liquid-line filter Large electrical panels organized for maximum efficiency and to facilitate ease of access Components Compressor Low Temperature Compressors offer 50%, 75% and 100% steps of capacity. Resulting in an optimal cooling solution for large capacity applications of all types. Compressors are rated for use with multiple refrigerants (R-404A, R-507A, R-407A, R-407F, R-448A & R-449A), allowing for flexibility Receivers are sized for sufficient pumpdown capacity of flood charges and include inlet and outlet service valves Oil Cooling All units are engineered with dedicated oil-coolers to match the requirements of your specific application Three-way mixing valve maintains oil return temperature. Motors Thermally protected, permanently lubricated ball bearing condenser and oil-cooler fan motors Controls System 450 controls provide reliable on/off controls and reduce installation time through a user-friendly interface which allows for ease of adjustment Nomenclature Rev. 10/17 S S V 060B L 6 D Model S = Single D = Dual Compressor Style S = V = Vertical 060B = B = B = B = B = B = 140 Airflow HP Operating Range Refrigerant Voltage L = Low 6 = R-404A R-507A R-407A R-407F R-448A R-449A Prices and specifications subject to change without notice. D = 460/3/60 E = 575/3/60 6
7 w/ Compressors Configurable Models Pricing Model List Price by Motor Voltage ($US) 460/3/60 575/3/60 Model Type SSV060BL6* 221, ,635 Single Compressor SSV070BL6* 241, ,778 Single Compressor DSV080BL6* 321, ,709 Dual Compressor DSV100BL6* 376, ,826 Dual Compressor DSV120BL6* 435, ,617 Dual Compressor DSV140BL6* 466, ,813 Dual Compressor * = Voltage Code Notes Need Factory-Installed Options? Factory-Installed Options remember to specify the option codes and list price adders for each selected option. Can t Find Something? Other options and accessories might be available on a custom order basis. Please contact your local Sales Representative or Account Engineer for assistance. List Price by Model Number ($US) Option Code Option Description SSV060BL6* SSV070BL6* DSV080BL6* DSV100BL6* DSV120BL6* DSV140BL6* Notes Coil Options CS.PRO Coated Fin Coil 8,431 8,431 11,804 13,123 14,442 17,099 CS.CPR Copper Fin Coil Call Factory CS.BRZ Bronz-Glow Coil Call Factory Cabinet Options Aluminum Cabinet No Charge Un-Painted Galvinized Cabinent (840) (840) (1,043) (1,182) (1,439) (1,695) Mechanical Options REC.001 Low Ambient Kit 2,509 2,509 5,018 5,018 5,018 5,018 SUC.005 Replaceable Core Suction Line Filter 3,387 3,387 4,237 4,237 4,237 4,237 Electrical Options Compressor Circuit Breaker No Charge Replaces Electronic Overload Relay VFD.001 Compressor VFD Call Factory MS.002 Variable Speed EC Motors - Rail-Mount 47,000 47,000 57,490 68,409 68,750 79,965 MS.001 Variable Speed EC Motors - Venturi-Mount 62,331 62,331 82,320 97,919 98, ,428 MCS.001 MCS Magnum Controller - No Defrost 3,063 3,063 7,926 7,926 11,213 11,213 MCS.002 MCS Magnum Controller - Defrost 6,713 6,713 9,927 9,927 13,735 13,735 * = Voltage Code Condenser & Oil-Cooler Fans. Only avaliable on 475v Condenser & Oil-Cooler Fans. Only avaliable on 475v Must be paired with an Electric Defrost Kit 7 Prices and specifications subject to change without notice. Rev. 10/17
8 w/ Compressors Need an electric defrost kit? Factory-Installed Electric Defrost Options remember to specify the option codes and list price adders for each selected option. Electric defrost kits and components are available to be factory mounted in the electrical box of indoor or outdoor condensing units used in medium/low temp applications with electric defrost evaporators. Option Code DFT.052 DFT.053 DFT.054 DFT.055 DFT.056 DFT.064 DFT.065 DFT.066 Description Models Used On Notes 2 Htr Cont 3 Htr Cont 4 Htr Cont 5 Htr Cont 6 Htr Cont 2 Fan 8 Htr Cont 2 Fan 10 Htr Cont 2 Fan 12 Htr Cont All Single Compressor All Single Compressor All Single Compressor All Single Compressor All All Dual Compressor All Dual Compressor All Dual Compressor Includes (1) evaporator fan contactor and (2) defrost heater contactor with terminal strip. Kit includes evaporator fan and Includes (1) evaporator fan contactor and (3) defrost heater Includes (1) evaporator fan contactor and (4) defrost heater Includes (1) evaporator fan contactor and (5) defrost heater Includes (1) evaporator fan contactor and (6) defrost heater Includes (2) evaporator fan contactors and (8) defrost heater Amp max load per evaporator fan contactor Includes (2) evaporator fan contactors and (10) defrost heater Includes (2) evaporator fan contactors and (12) defrost heater List Price Adder ($US) 3,415 4,240 5,066 6,773 8,841 10,132 13,546 16,962 Rev. 10/17 Prices and specifications subject to change without notice. 8
Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV
LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV Table of Contents Nomenclature Chart... 2 Features and Benefits...3
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationBN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ
BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR 2015 Air-Cooled Condenser with Microchannel Coil Technology Models NRG NRJ Table of Contents Nomenclature... 2 Features & Benefits... 3 Capacity and Specifications...
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationhorizontal air discharge outdoor discus condensing unit
CC-HADTB March 2007 (Replaces CC-B-48D, 10/04) CLIMATE CONTROL horizontal air discharge outdoor discus condensing unit Technical Guide CDH Standard & Optional Features CDH Outdoor Discus Condensing Units,
More informationKramersaver Air Cooled Condensing Units
Catalog KM-KSX-0613A Kramersaver Series Kramersaver Air Cooled Condensing Units Models C & KS 4 through 70 HP Kramer C and KS model condensing units are available in 4 to 70 HP. While the basic C model
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationT H I N K I N S I D E T H E B o x
T H I N K I N S I D E T H E B o x HyperCoreTM microchannel coil technology The name behind the brands you trust. 2175 West Park Place Blvd. Stone Mountain, GA 30087 www.heatcraftrpd.com P 800.537.7775
More informationAir-Cooled Condensing Units with Bitzer Compressors
CH-CUBZTB JAN 2018 Replaces CH-CUBZTB APRIL 2011 Air-Cooled Condensing Units with Bitzer s Technical Guide s BLV BDVS JLD JDDS Table of Contents Floating Tube Coil... 3 Beacon II Options... 4 Adjustable
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationDOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationLK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.
LK-TSSTB July 2009 FPO 5-30 HP Two Stage Condensing Units and Systems Technical Guide with Bitzer s www.larkinproducts.com Table of Contents Standard Features... 2 Nomenclature... 2 Condensing Unit Capacity...
More informationAir-Cooled Condensers
Catalog Cat 622-2 Air-Cooled Condensers Model ACH 014-225 Model ACX 014-225 Model ACL 014-225 Capacities from 130 MBH to 2225 MBH R-134a, R-407c, R-410A Table of Contents Introduction...3 Model Description...4
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationHEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES
SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES 1-year warranty on parts and labor. 5-year compressor warranty. If Registered a 10 year limited parts warranty applies. Designed for maximum
More information3-22 HP CONDENSING UNITS Technical Guide
BN-HCUTB September 2015 Replaces BN-HCUTB, March 2015 3-22 HP CONDENSING UNITS Technical Guide Scroll and Discus s heatcraftrpd.com TABLE OF CONTENTS Nomenclature...2 Standard Features...3 Options...3-4
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More informationCONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00
BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from
More informationProduct Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.
Product Data GEMINI 38AKS028-044 Commercial Air-Cooled Split Systems 50/60 Hz 25 to 40 Nominal Tons (82.8 to 127.0 kw) These dependable split systems match Carrier s indoor-air handlers with outdoor condensing
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationINTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies
Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationDTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5
Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationA Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-
A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job
More informationProduct Chillers A P P L I C AT I O N S
Product Chillers A P P L I C AT I O N S Wineries Bottling Product Storage Product Ripening Meat Processing Florist Boxes Packaging Rooms Walk-in Coolers Beverage Boxes CENTURY PRODUCT CHILLERS Unit Configuration
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationIndustrial Unit Coolers
HC.CH-IUC l March 2016 Industrial Unit Coolers Sales Brochure We Know Cold Storage Heatcraft Worldwide Refrigeration announces its latest addition of large capacity unit coolers for the Cold Storage and
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationAir-Cooled Condensers
CH-RACCTB APR 2015 Replaces CH-RACCTB April 2011 Air-Cooled Condensers Technical Guide Models WSS Table of Contents Features & Options...2 Condenser Selection... 3-4 Performance Data...5 Dimensional Data...5
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More information500 EX Fusion Compressor Series
500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PSH4BF Series M1010 Product Line R-410A Ultra High Efficiency Heat Pumps 15+ SEER 2-5 Ton 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE Maytag
More informationUnit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60
Unit Dimension Unit Nomenclature DEHUMIDIFIER NOMENCLATURE R K D A - 0050 - C Z - M 4-8 UNIT VOLTAGE: 2: 240/1/60 5: 208-240/3/60 9: 480/3/60 8: 600/3/60 REFRIGEREANT R-404a MEDIUM TEMPERATURE SCROLL COMPRESSOR
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More information13 GEP A L P - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP MERIT SERIES Residential - R-40A Bulletin No. 20602 December 202 Supersedes October 202 SEER - 3.00 AFUE - 80% 2 to 5 Tons Cooling Capacity - 22,800
More informationCenter Mount Unit Coolers
CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4
More information60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES
60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,
More informationDT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity
TECHNICAL SPECIFICATIONS DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System 1.5-5 Ton The DT5BD Series of heat pumps offers exceptional performance. The heat pump, when combined with our
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationPS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS
PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS PS Series Parallel Racks For those who want to maximize energy savings and have full control of an entire refrigeration network within a facility, PS
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationAir-Cooled Condensers
Catalog Cat 622-3 Air-Cooled Condensers Model ACH 014-225 Model ACX 014-225 Model ACL 014-225 Capacities from 130 MBH to 2225 MBH R-134a, R-407c, R-410A Table of Contents Introduction...3 Model Description...4
More informationHi-Pres Cooling Products Catalogue. Product Catalogue
Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product
More informationCONDENSERS AND CONDENSING UNITS
CONDENSERS AND CONDENSING UNITS CF Series Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationNext-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS
Publication No. CZ-CFH-0617A Replaces document CZ-CFH-0117A Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of Uni-Paks are Here! ColdZone s
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationDUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C
DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure
More informationCB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:
CB/CF CONDENSERS AND CONDENSING UNITS CF CB Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity
More informationLow Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.
LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of
More informationGuide Specifications PART 1 GENERAL 1.01 SUMMARY
Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control
More informationLo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.
bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features
More informationMLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers
MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS
More informationTechnical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307
DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application
More information30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz
30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB
More informationA. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.
15684 ROTARY SCREW WATER CHILLERS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 236423 An optional
More informationCopeland Scroll Outdoor Refrigeration Unit
Copeland Scroll Outdoor Refrigeration Unit Medium and low temperature applications Convenience Store Restaurant R-22, 134a, 404A/507A, 407C/A, 448A/449A 1.5-6 HP Innovative design based on three factors
More informationFor Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog
For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X Air Cooled Medical Chiller Product Data Catalog Product Introduction Multistack products are ideal for many mission
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationWater-Cooled Self-Contained Units
CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationCompressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers
Refrigerated Air Dryers Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. 107 W. Main St. Worthington, Pennsylvania 16262 Phone: (724) 297 3416
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationTABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6
TABLE OF CONTENTS Page FCV Nomenclature 3 FCV Features & Construction 4 FCV Engineering Specifications 5 FCV Fan/Coil Data 6 FCV Unit Weights and Volumes 7 FCV Fan and Motor Data 8-9 Dimensions 10-14 Standard
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE CAS Product Specifications Single stage cooling capacity control on all models with Micro channel
More informationSeries PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection
Series PIC New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction and Renovation; Replaces
More informationSECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:
SECTION 15684 ROTARY SCREW WATER CHILLERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15540 - Pumping Equipment (HVAC). 3. 15711 - Induced Draft Cooling Tower. B.
More informationTrailblazer air cooled scroll chillers
Trailblazer air cooled scroll chillers Changing the way you think about air cooled chillers 30 to 240 tons with Variable Speed Condenser Fan Technology People and ideas you can trust. Changing the way
More informationORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS
ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationSECTION WATER-SOURCE UNITARY HEAT PUMPS
SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationPRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications
DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL
More informationMODELS LIST. Nominal Capacity RT
1. MODELS LIST. NOMENCLATURE 3. FEATURES 4. PRODUCT DATA 5. PERFORMANCE CORRECTION 6. ANTIFREEZE 7. INSTALLATION 8. ELECTRICAL DATA 9. SCHEMATIC WIRING DIAGRAM 10.MICROPROCESSOR CONTROLLER 11.APPLICATION
More informationRefrigeration Plant Information. We Speak Hockey 365
Refrigeration Plant Information We Speak Hockey 365 Introduction For 100 years, it s been accepted that ice rinks come with a multitude of expensive and reoccurring problems; not to mention astoundingly
More informationENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL
ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS
More informationAir-cooled Screw Chillers Model RTAF G Process
Air-cooled Screw Chillers Model RTAF G Process Near 0 GWP (
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise
More informationT-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N
T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY
More informationCS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)
CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationCatalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers
Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers Models RCS 025C through 135C 25 to 135 Tons R-22/R407C Refrigerant Catalog 221-1 Table of Contents Introduction.... 3 The Condensing
More informationCoil-In-Tank Design: Refrigeration System: Cabinet Construction:
Rite-Temp Manufacturing pioneered the development of refrigerated industrial water chillers in 1948. Since the first Rite-Temp units were introduced, quality engineering and manufacturing has been a key
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationAir-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers
Catalog 221-1 Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers Model RCS 025C to 135C R-22/R-407C Refrigerant Contents Introduction............................... 3 The Condensing
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof
More information