TEMPRO Mold Temperature Controllers. Superior Temperature Control. Technology working for you.
|
|
- Horatio Roberts
- 6 years ago
- Views:
Transcription
1 TEMPRO Mold Temperature Controllers Superior Temperature Control Technology working for you.
2 Superior TEMPRO plus D Touch-Screen Series for Perfect Quality Latest design technology and operation In pressurized operation, a gauge ensures that the internal pressure is always bar min. over the steam pressure curve. Because of the smaller heat exchanger there is less circulating water. As a result, the preheating time and the cool down period have been reduced. Booster pump (for filling under pressure at temperatures of more than C) Touch-screen display,.7", Windows CE Heat exchanger made of stainless steel (Incoloy heating element) Pump and system pressure gauges Maintenance free magnetically coupled pump (standard in the TEMPRO plus D//8) Heating control via solid state relay Optimum visibility and operation of the TEMPRO plus D Touch-screen The actual value and set point are displayed simultaneously. Visual temperature control The mold symbol color indicates if the temperature is in the tolerance band (green: within tolerance; red: too hot; blue: too cold). Additional information on the display The operator can choose an additional value to be displayed on the screen (pressure, flow). Easy operation with the TEMPRO plus D Menus to adjust values and to choose operating modes can be selected with color touch-screen. Quick selection Operating modes that are used frequently can be selected using the touch fields at the bottom of the screen. Standard equipment for the TEMPRO plus D series Microprocessor controller with ±. C accuracy. Automatic filling and constant pressure monitoring. Pressure gauges (system and pump pressures). Automatic pump rotation detection. Maximum temperature monitoring. Heater control with solid state relay. Pumps safe to run dry. Backflow sensor. Sensor break monitoring. External sensor socket for PT sensors. Air purging (unlimited mold purge for / units). Timer (time switch). Potential-free dry contact for alarm output plus audible alarm. Operating hours counter with service interval indicator. Options: Flow control and measurement Communications interfaces Mold sensor FeCo (Type J) socket
3 TEMPRO plus D9///8 Circulating Water Single and Dual Zone Units TEMPRO plus D9 - For temperatures up to 9 C. - Open system with powerful, submersible pumps without pump seals. TEMPRO plus D//8 - For temperatures up to C, C and 8 C. - Pressurized system with powerful pumps and with magnetically coupled pumps for TEMPRO plus D//8. TEMPRO plus D 9 8 Microprocessor controller, self-optimizing Maximum temperature monitoring Sensor break monitoring Automatic filling with leakage and pressure monitoring Automatic pump rotation direction detection Dry contact for alarm output plus audible alarm Connectors for external sensors PT Connector for external mold sensor FeCo Type J Leakstop function Mold purging through pump rotation change (max. l) Mold purging through pump rotation change (unlimited) Enhanced pump [ = magnetically coupled] Pressure measuring (system, pump, and flow pressure) Flow measuring [ = vortex, = ultrasonic] Boost pump [ = two pumps] Serial interface (RS, RS 8, ma, CAN, SPI) Operating hour counter/clock timer/service monitoring Variotherm tempering Standard equipment Optional equipment no supply for this model pump characteristics TEMPRO plus D9 TEMPRO plus D9 standard TEMPRO plus D9 enhanced Q [l/min] TEMPRO plus D 9 /8 Heating capacity 9 kw (option: kw) Pump capacity ( Hz) standard Pump capacity ( Hz) enhanced. kw, max..8 bar max. l/min kw, max..8 bar max. l/min magnetically coupled. kw, max.. bar max. l/min magnetically coupled kw, max. bar max. l/min Cooling water conn. G /" + G /8" G /8" Mold connection G /" standard x 8 V/ Hz magnetically coupled. kw, max. bar l/min magnetically coupled kw, max. bar max. l/min 7 pump characteristics TEMPRO plus D//8 Q [l/min] TEMPRO plus D standard TEMPRO plus D enhanced TEMPRO plus D/8 standard TEMPRO plus D enhanced TEMPRO plus D/8 enhanced Single zone Dual zone 8 cooling capacity diagram TEMPRO plus D cooling capacity [kw] t = temperature difference cooling water and process water [ C] TEMPRO plus D9 cooling coil enhanced (fin-surface) cooling coil standard (smooth finish) TEMPRO plus D//8 cooling coil enhanced (fin-surface) cooling coil standard (smooth finish)
4 TEMPRO plus With Thermo-oil Perfect quality up to C. Precision Control Microprocessor controlled until ± C accuracy. User Friendly Simplistic Display Double Level Control Refill warning, automatic switch-off. Process Pressure Gauges Standard Line Evacuating for Mold Purge Magnetically Coupled Pump Without Seal TEMPRO plus Microprocessor controller, self-optimizing Standard equipment Optional equipment no supply for this model Maximum temperature monitoring Automatic heater control (max. heating power kw) Process pressure gauges standard Level control max./min. (message for refilling/safety switch off) Safety temperature limiter Automatic pump rotation direction detection Serial interface (RS, RS 8, ma) 7 pump characteristics TEMPRO plus Socket for external sensor PT Socket for external mold sensor FeCo Type J Magnetically coupled pump without seal Automatic venting of system pressure Line evacuating for mold changing Sensor break monitoring Q [l/min] Back flow sensor Dry contact for alarm output plus audible alarm Operating hour counter, indication of several intervals TEMPRO plus Heating capacity max. kw Pump capacity ( Hz) kw, max. 7 bar, max. l/min Cooling water connection G /" Mold connection G /" standard x 8 V/ Hz cooling capacity diagram t = temperature difference cooling water and process water TEMPRO plus 79 cooling capacity [kw] [ C] 9
5 TEMPRO plus XL 9 Water Units WITTMANN s TEMPRO plus XL 9 can heat up even big molds within a short time to the required set point. Besides the strong heater ( kw) we have reinforced flow (up to l/min) and cooling capacity. Purge out of molds is supported by an additional pump which pumps the water to the return line or drain. Thus the purge volume is increased. TEMPRO plus XL 9 Microprocessor controller, self-optimizing Maximum temperature monitoring Sensor break monitoring Automatic filling with leakage monitoring and level control Standard equipment Optional equipment no supply for this model Dry contact for alarm output plus audible alarm Connector for external sensors PT Connector for external mold sensor FeCo Type J Leakstop function pump characteristics TEMPRO plus XL9 Air purging for mold changes Pressure gauge/flow indication Serial interface (RS, RS 8, ma) Operating hour counter/service monitoring 8 TEMPRO plus XL9 standard TEMPRO plus XL9 enhanced 8 Q [l/min] TEMPRO plus XL 9 Heating capacity 8 kw (option: kw) Pump standard T-/ Hz. kw, max. bar, max. l/min Pump enhanced T-/ Hz.8 kw, max. bar, max. l/min Cooling water connection G /" Mold connection G /" standard x 8 V/ Hz cooling capacity diagram t = temperature difference cooling water and process water TEMPRO PLUS XL 9 98 cooling capacity [kw] [ C]
6 TEMPRO primus C9/basic C9/basic C The Economic Solution The ideal temperature controller for any application requiring exact temperature control and high user-friendliness, however without additional functions such as direct cooling. TEMPRO primus C9 Single zone temperature controller up to 9 C. Standard features include air purging for mold changes. TEMPRO basic C9 One circuit temperature controller for temperatures up to 9 C equipped with a selfoptimizing microprocessor controller (± C). Standard with leakstop function and hand selector switch for evacuating function. TEMPRO basic C Single zone unit with pressurized system for temperatures up to C. The economic mold temperature controller for precise temperature control up to C. TEMPRO primus C9 basic C9 basic C Microprocessor controller, self-optimizing Maximum temperature monitoring Sensor break monitoring Automator filling with leakage monitoring and level cont. Dry contact for alarm output Connectors for external sensors PT Leakstop function / Mold purging through pump rotation change / Reinforced pump Manual filling Pressure gauge/flow indication Serial interface (RS, RS 8, ma) Analog interface ( ma / V) Operating hour counter/service monitoring Horn Standard equipment Optional equipment no supply for this model pump characteristcs TEMPRO primus/basic C9/C TEMPRO primus/basic C9 standard TEMPRO basic C9 enhanced TEMPRO basic C standard TEMPRO basic C enhanced Q [l/min] TEMPRO primus C9 basic C9 basic C Heating capacity Pump capacity ( Hz) Standard Pump capacity ( Hz) enhanced 9 kw. kw, max.. bar, max. l/min.7 kw, max.. bar max. l/min. kw, max. bar max. l/min.7 kw, max. bar max. l/min Cooling water connect. G /" G /8" To mold from mold G /" / G /" G /" standard x 8 V/ Hz cooling capacity diagram t = temperature difference cooling water and process water TEMPRO basic C9 TEMPRO basic C Basic C Basic C9 cooling capacity [kw] [ C] 7
7 TEMPRO primus C/direct C The TEMPRO primus C is used for temperatures up to C. Due to direct injection of the cooling water, it is providing an exceptionally high cooling capacity. The TEMPRO direct C was designed for the special requirements of specific applications. It is equipped with radial pumps for high flow volumes at different pressure ranges: an economic mold temperature controller series with high user-friendliness and an extensive equipment range for every application. TEMPRO primus C direct C Microprocessor controller, self-optimizing Maximum temperature monitoring Sensor break monitoring Automator filling with pressure monitoring Dry contact for alarm output + audible alarm TEMPRO primus C Connector for external sensor PT Mold purging through pressurized air Enhanced pump Pump made of bronze Pressure gauges in pump advance and return flow Serial interface (RS, RS 8, ma) Analog interface ( ma / V) Operating hour counter/service monitoring Horn Options: cooling valves G/", G/", G" TEMPRO primus C direct C TEMPRO direct C Heating capacity 9kW 9 kw (optional 8 kw) Pump capacity Standard Pump capacity enhanced (max. bar/max. l/min). kw. bar l/min.7 kw, max.. bar max. l/min. kw. bar l/min Dimensions (w/h/d) 7 x x x 8 x 7 Cooling water connect. G / G Mold connection G / G / Standard cooling valve G /8" standard x 8 V/ Hz kw.9 bar 8 l/min pressure [bar] pump characteristics according Hz flow [l/min].7 kw. kw. kw. kw cooling water flow rate [l/min] cooling capacity cooling capacity in [kw] Temperature difference: C Temperature difference: C Temperature difference: C Temperature difference: C Temperature difference: C flow [l/min] cooling valve flow capacities.... difference pressure [bar] /8" /" /" " 7
8 WITTMANN Kunststoffgeräte GmbH Lichtblaustrasse Vienna Austria Tel.: + 9- Fax: info.at@wittmann-group.com Technology working for you. Temperature Controllers Article number: BP (English) / Subject to change.
Superior Temperature Control. world of innovation
TEMPRO Mold temperature Controllers Superior Temperature Control world of innovation TEMPRO plus D Touch-Screen Series for Perfect Quality Latest design technology and operation In pressurized operation,
More informationSuperior Temperature Control. world of innovation
TEMPRO Mold temperature Controllers Superior Temperature Control world of innovation TEMPRO plus D Touch-Screen Series for Perfect Quality Latest design technology and operation In pressurized operation,
More informationSuperior Temperature Control. world of innovation
TEMPRO Mold temperature Controllers Superior Temperature Control world of innovation TEMPRO plus D Touch-Screen Series for Perfect Quality Latest design technology and operation In pressurized operation,
More informationGranulators Reprocessing Plastic Scrap into Valuable Regrind. world of innovation
Granulators Reprocessing Plastic Scrap into Valuable Regrind world of innovation Beside-the-press Conventional Blade Granulators The G-Max Series Smart Engineering in Compact Granulators New Range Specifically
More informationGranulators Reprocessing Plastic Scrap into Valuable Regrind. world of innovation
Granulators Reprocessing Plastic Scrap into Valuable Regrind world of innovation Beside-the-press Conventional Blade Granulators The G-Max Series Smart engineering in compact granulators Specifically designed
More informationDRYMAX Dryers. Dry Air Dryers for Plastic Resin
DRYAX Dryers Dry Air Dryers for Plastic Resin DRYAX ES0 Dry Air Dryer The DRYAX ES 0 compact dry air dryers are equipped with one desiccant bed and provide a dry air volume of 0 m /h. Ambient Independent
More informationConveying Systems For Plastics Processing Plants
FEEDMAX Conveying Equipment Conveying Systems For Plastics Processing Plants FEEDMAX S 3-net Single Material Loader Optimized single loader for flexible conveying of smaller material volumes of up to 20
More informationConveying Equipment. Conveying Systems for Plastics Processing Plants. world of innovation
Conveying Equipment Conveying Systems for Plastics Processing Plants world of innovation FEEDMAX S 3-net Single Material Loader Optimized single loader for flexible conveying of smaller material volumes
More informationPRESS RELEASE. Industry 4.0 technologies and processes at the Plastpol WITTMANN BATTENFELD at the Plastpol in Kielce
April 2018, Kottingbrunn/Austria PRESS RELEASE WITTMANN BATTENFELD at the Plastpol in Kielce Industry 4.0 technologies and processes at the Plastpol 2018 At the Plastpol 2018, from 22 to 25 May, the WITTMANN
More informationDryers Dry Air Dryers for Plastic Resin. world of innovation
Dryers Dry Air Dryers for Plastic Resin world of innovation energy rating Energy savings and highest efficiency at the same time After several years of research, WITTANN has developed a standardized rating
More informationThermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine
Thermo Scientific Round Top Hotplate Stirrers Make safety and accuracy part of your routine Thermo Scientific Round Top Hotplate Stirrers Our portfolio of roundtop hotplates, stirrers and stirring hotplates
More informationTemperature controllers TW, TO and TP, Speedy Therm
Temperature controllers TW, TO and TP, Speedy Therm English Compact dimensions, stainless steel tanks, internal reservoirs and couplings, high capacity peripheral pumps and electronic control board unify
More informationSENTRA Series Water Unit
SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)
More informationConstant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:
Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationWITTMANN at the Fakuma 2018
NEWS RELEASE August 30, 2018 [Witt-NR-15-2018_Fakuma-Information] WITTMANN at the Fakuma 2018 This year, the WITTMANN Group is again taking the opportunity to present its most recent product developments
More informationKMF Environmental test chamber for constant climate
SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The
More informationWITTMANN BATTENFELD at the Chinaplas 2018 in Shanghai WITTMANN BATTENFELD with high-tech machines and processes at the Chinaplas in Shanghai
February 2018, Kottingbrunn/Austria PRESS RELEASE WITTMANN BATTENFELD at the Chinaplas 2018 in Shanghai WITTMANN BATTENFELD with high-tech machines and processes at the Chinaplas in Shanghai From April
More informationPlant growth chambers
Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect
More informationRecirculating Coolers
09 Recirculating Coolers (chillers) General Recirculating Coolers Low Temp. Recirculating Coolers Advanced Low Temp. Recirculating Coolers High Temp. Recirculating Coolers Compact Recirculating Cooler
More informationBAC 4000a BAC 5000yf
AC Service Units BAC 4000a BAC 5000yf AC Service Units Recommended by Volvo Cars Fully-automatic, high capacity and comfortable Maximum safety Easy to use BAC 4000a Maximum precision easy operation. The
More informationThermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine
Thermo Scientific Round Top Hotplate Stirrers Make safety and accuracy part of your routine Thermo Scientific Round Top Hotplate Stirrers Our portfolio of roundtop hotplates, stirrers and stirring hotplates
More informationEffective and energy-conscious temperature control. Significantly increasing productivity. integrat Segmented mould temperature control
Effective and energy-conscious temperature control. Significantly increasing productivity. integrat Segmented mould temperature control integrat direct integrat direct is innovative gwk-technology for
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationIndustrial cooling systems LT
Industrial cooling systems LT 01 Industrial cooling and heating. Partner of the industry for over 40 years. Since 1971 DELTATHERM has belonged to Hirmer GmbH, a family business with its headquarters in
More informationTHE NEW GENERATION VACUUM PUMP SYSTEM SC
THE NEW GENERATION VACUUM PUMP SYSTEM SC 920 with wireless remote control Fast and precise from afar: Vacuum pump system with wireless remote control The new vacuum pump system SC 920 now supports remote
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationTemperature Controllers TW, TO, TP Series
Temperature Controllers TW, TO, TP Series English The TW, TO and TP series of Piovan mould temperature controllers has been designed to maintain at a constant temperature the mould cavities, the hydraulic
More informationModular temperature controllers
Modular temperature controllers Choosing the right temperature controller Water/oil direct/indirect cooling Process-optimized temperature control Customer-specific and process-optimized heating and cooling
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A
SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist
More informationChemistry diaphragm pumps
Oil-free vacuum for corrosive gases and vapors Chemistry diaphragm pumps Series overview Examples of use Down to 70 Pumping of aggressive gases and vapors For low-boiling solvents Vacuum filtration Down
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationInnova M4, M5 and M5-ISo
Atherton M4, M5 and M5-ISo Clean solutions in the CSSD Quality Management System Certified by DQS according to DIN EN ISO 9001: 2000 DIN EN 13485: 2003 Reg. No. 019906-01 M4, M5 and M5-ISo Flexible equipment
More informationThermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific
Thermo Scientific Heratherm efficient safe easy Part of Thermo Fisher Scientific Thermo Scientific Heratherm your samples We are obsessed with sample integrity. Each of our new laboratory heating and drying
More informationModel KBF 240 Constant climate chambers with large temperature / humidity range
Model KBF 240 Constant climate chambers with large temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Pressure
More informationFEEDMAX Conveying Equipment. Conveying Systems For Plastics Processing Plants. Technology working for you.
FEEDMAX Conveying Equipment Conveying Systems For Plastics Processing Plants Technology working for you. FEEDMAX S3 net Single Material Loader Optimized single loader for flexible conveying of smaller
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationConstant climate chamber with humidity
KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationConstant climate chamber with ICH-compliant illumination
KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert
More informationDC200 Digital Dispenser Operating Manual
DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationDRYMAX Dryers. Dry Air Dryers for Plastic Resin. Technology working for you.
DRYAX Dryers Dry Air Dryers for Plastic Resin Technology working for you. DRYAX P Compressed Air Dryer The drying principle is based on pre-dried, factory supplied compressed air which expands within the
More informationWITTMANN BATTENFELD with full Power at the Plast in Milan
May 2018, Kottingbrunn/Austria PRESS RELEASE WITTMANN BATTENFELD at the Plast 2018 in Milan WITTMANN BATTENFELD with full Power at the Plast in Milan From May 29 to June 1, WITTMANN BATTENFELD will present
More informationIntelligent. Powerful.
English Dynamic. Intuitive. The all-new DYNEO series boasts high-performance and high-quality components as well as a wide range of modern data communication interfaces. Operation and handling is made
More informationVACUUM HEATING AND DRYING OVENS Gentle and safe
VACUUM HEATING AND DRYING OVENS Gentle and safe Quality Products Lifetime Care VACUTHERM 6000 USER FRIENDLY AS NEVER BEFORE The intelligent, modular system: three sizes and two types of heating Series
More informationIntelligent control systems Compressor control systems Overriding control systems Central instrumentation and control
Intelligent control systems Compressor control systems Overriding control systems Central instrumentation and control Intelligence, innovation, reliability considerably reduce power costs think, monitor,
More informationXRD XRD-1500 High-Temperature Oven. Innovation in Material Science...
XRD-1500 XRD-1500 High-Temperature Oven Innovation in Material Science... New materials science calls for refined tools that enable X-ray research in well-defined environments and under controlled temperature
More informationSilencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter
VALLOX Product Code: 3158400 L 3158410 R SILENCER (OPTIONAL) INSTRUCTIONS FOR USE AND MAINTENANCE WATER CIRCULATED POST-HEATING UNIT (OPTIONAL) ELECTRIC POST-HEATING UNIT (OPTIONAL)) PREHEATER (OPTIONAL)
More informationThermo Scientific Heratherm Heating and Drying Ovens. efficient
Thermo Scientific Heratherm efficient safe easy Thermo Scientific Heratherm your samples We are obsessed with sample integrity. Each of our new laboratory heating and drying ovens is designed with sample
More informationVacuum in the laboratory. products and solutions
Vacuum in the laboratory products and solutions Vacuum filtration is frequently used for sample preparation in microbiology, waste water control and analysis. With a final vacuum of 100 mbar, 90% of atmospheric
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationDriven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf
Driven by CLIMATISATION Excellence for professionals Bosch air conditioning service units for R-134a and R-1234yf A/C service from Bosch Air conditioning systems in vehicles require regular maintenance.
More informationModel KMF 720 Constant climate chambers with expanded temperature / humidity range
Model KMF 720 Constant climate chambers with expanded temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Humidification
More informationVacuum drying VD VDL series
Vacuum drying VD VDL series Extremely superior: BINDER Vacuum drying ovens u Extremely fast u Direct heat transfer to the sample material through thermal conducting plates u Fast, condensation-free drying
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationConstant climate chambers
Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationKey benefits. Why Condair CP3?
Condair Cp3 Humidification The Electrode Steam Humidifier. Powerful and User-Friendly Why? Tailored technology. You can program your specifications exactly to the last kilogram with the CP3 Card. This
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationGuide Specifications for InRow Direct Expansion
Guide Specifications Guide Specifications for InRow Direct Expansion THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT. THIS SECTION MUST
More information30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationCustom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2
The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer
More informationearth safe Fuel Systems for Critical Power
BACnet, Modbus, Metasys N2, or LON Communications General Description Safe Fuel Storage Inside Buildings. Earthsafe day tanks safely store fuel for generarator engine consumption within the building. Day
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated
More information573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:
Industrial Chilled Mirror Hygrometer Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System ForceFrost TM function Ice-Test user calibration verification User configurable
More informationShop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.
Shop Item Information Send item information Show item in shop Add item to cart Interface I-100 For V-100/V-7x0 Item Information Item No. Availability 11I100002 on stock Attribute Overview Compatibility
More informationEnvironmental Chambers
Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm
More informationHIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)
HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS #116075 (TED1-8074) 2004 IMS Co. October, 2004 IMS Company 10373 Stafford Road Chagrin Falls, OH 44023-5296 Telephone: (440) 543-1615 Fax: (440)
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather
More informationModel KMF 115 Constant climate chambers with expanded temperature / humidity range
Model KMF 115 Constant climate chambers with expanded temperature / humidity range BENEFITS Homogeneous climate conditions thanks to APT.line technology Automatic water and wastewater management Humidification
More informationSERIES CONVECTION OVENS
SERIES CONVECTION OVENS SERIES BCO G BCO-G1 with optional casters Built tough & rugged like our more expensive models, the BCO models are our least expensive, full-size convection ovens. They feature independent
More informationEnvironmental simulation chamber for complex alternating climate profiles
MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited
More informationBench-Top Type Temperature (& Humidity) Chamber
Bench-Top Type Temperature (& Humidity) Chamber SHSU CAT.NO.E01111-M102 Compact design for personal use, to network with your computer. The Bench-top Type Temperature (& Humidity) Chamber Series features
More informationSmart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)
- Smart-Lab system (SWOF, SWON models) - Digital Fuzzy Control System Implementing Superior Temperature Accuracy - New Jog-Dial for Users to operate in an easy and Converient way - er Temperature & er
More informationExciting Swiss temperature control technology, distributed in North America exclusively by...
Exciting Swiss temperature control technology, distributed in North America exclusively by... TM North America Frigel North America, Inc. 150 Prairie Lake Rd, Unit A East Dundee, IL. 60118 USA Tel (847)
More informationBooster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm
Booster Compressors N Series Pressures to 650 psig Capacities 9.5 to 724 cfm High Pressure Systems from Kaeser PET plastics, molding, leak testing and other special applications require higher pressures
More informationPowerful and reliable. Also for high ambient temperatures. weco Compact chillers
Powerful and reliable. Also for high ambient temperatures. weco Compact chillers The smart approach to cooling. Energy-effic Innovative technology The new compact chillers are equipped according to the
More informationDehumidifying Dryers DP DP 615 Series
Dehumidifying Dryers DP 604 - DP 615 Series English The DP 604 - DP 615 Dryer Series is suitable for the treatment of hygroscopic polymers for medium productions. The design criteria of these models allows
More informationThermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy
Thermo Scientific Heratherm Heating and Drying Ovens Efficient, safe and easy Thermo Scientific Heratherm Heating and Drying Ovens your samples We are obsessed with sample integrity. Each of our new laboratory
More informationHydronic Mechanical Panels
Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc.
More informationPUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling
PUT WASTE HEAT TO USE with our gas-heated steam humidifier, Humidification and evaporative cooling Cost-effective and eco-friendly steam production with gas as the primary energy source Touch Controller
More informationCondair Mk5. Getting rid of scale. The steam humidifier with scale management. Low maintenance. Reliability. And superior control accuracy
Condair Mk5 Getting rid of scale The steam humidifier with scale management. Low maintenance. Reliability. And superior control accuracy Humidification and Evaporative Cooling Why Defensor Mk5? Flexible.
More informationStandard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series
Standard-Incubators Avantgarde.Line BD BF series Classic.Line B BD BF series Solid.Line BD-S series EN PRODUCT SELECTION INCUBATORS Classic.Line Classic.Line Avantgarde.Line Solid.Line Classic.Line Avantgarde.Line
More informationTechnical Data Manual
VITOTRONIC 300 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Technical Data Manual Vitotronic 300 Model KW3, Part No. Z001 231 For operation
More informationNEW INTELLIGENT AIR TECHNOLOGY
L Series L07 L11 (10 15 HP) Rotary Screw Compressors NEW INTELLIGENT AIR TECHNOLOGY L07 L11 ROTARY SCREW COMPRESSORS The L Series oil injected rotary screw compressors provide a range that combines high
More informationVICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS
PRODUCT INFORMATION VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS Tunnel sensors EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY
More informationTop Performance A New Level of Washing Efficiency
PT Series Rack pass-through dishwashers PT-M, PT-L, PT-XL Top Performance A New Level of Washing Efficiency The PT Series a new generation of Winterhalter pass-through dishwashers sets the market standard.
More informationXLH210: controller for gas leak detectors
pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationCultivator & Hybrid Cultivator
Cultivator & Hybrid Cultivator Precision Temperature & Humidity Packaged Unit INTRODUCTION The Cultivator Series package unit is the industry s MOST ENERGY EFFICIENT and HIGHEST capacity dehumidifier on
More informationCONTENTS >> VACUUM OVEN. General Description. Shelves Detail. Vacuum Drying Oven. -Feature. -Specification. 350 Vacuum Drying Oven.
VACUU Oven M 03 CONTENTS >> VACUUM OVEN General Description Shelves Detail 68 69 Vacuum Drying Oven -Feature -Specification 70 72 350 Vacuum Drying Oven -Feature -Specification 76 78 450 Vacuum Drying
More informationCentral Chillers TS Series
www.thermalcare.com Central Chillers TS Series With over 40 years of process cooling experience, Thermal Care is the dependable choice for industrial process chillers. Our TS Series is just one of several
More informationDrying and heating chambers
Drying and heating chambers Avantgarde.Line ED FD FED series Classic.Line E ED FD FED FP M series Solid.Line ED-S FD-S series EN PRODUCT SELECTION DRYING AND HEATING CHAMBERS Classic.Line Avantgarde.Line
More informationUser s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas
User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5
More informationUDC100 Universal Digital Controller Specifications
UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationgforce Units Data Aire and Data Temp Series
gforce Units gforce gforce is the most advanced mission critical cooling equipment available on the market today. These units are the most efficient and economical while complying with strict environmental
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationModel MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature
More informationPAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s
PAPANTONATOS P u m p s s e r v ic e & e n g i nee r in g We supply clean water and remove waste water s e w a g e p u m p s submersible pumps The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45
More information