TOSHIBA AIR CONDITIONING

Size: px
Start display at page:

Download "TOSHIBA AIR CONDITIONING"

Transcription

1 Introduction The following specification describes the Toshiba Estia Air to Water Heat Pump system(s) to be installed at the site below: (ADD SITE NAME) The system(s) shall consist of the following components. It shall be the responsibility of the nominated installer to supply and install these system components in accordance with Toshiba Installation Guidelines. 1) Toshiba Estia Inverter external air cooled condensing unit(s) 2) Toshiba Estia Hydro box indoor unit(s) 3) Toshiba Domestic Hot Water Cylinder(s) 4) Interconnecting refrigerant pipe work from Outdoor Unit(s) to HydroUnit(s). System Operating Range Mode of operation Cooling Heating DHW Max. Outdoor Air Temperature Min. Outdoor Air Temperature 0 C db C db Min / Max Leaving Water Temperature 0 C 10 to to to 75 System Description The installation shall provide an energy efficient R410A Direct Expansion (DX) split type Air to Water Heat Pump system(s) and shall be installed in accordance with relevant codes of practice and regulations. The system(s) shall comprise of a Toshiba Estia Inverter Heat Pump outdoor unit(s) connected to a Toshiba Estia hydro module unit(s). It is recommended that the refrigerant system installing contractor is a Refcom Certified Toshiba Additions Member. Full details on our website: Customer Support. The system(s) shall be controlled with Toshiba s in-built controls system. DELETE WARRANTIES THAT DO NOT APPLY All equipment supplied shall have a manufacturer s warranty of at least 3-years on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Registered installer or Qualified or Accredited

2 All equipment supplied shall have a manufacturer s warranty of 5-years on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Qualified or Accredited installer. All equipment supplied shall have a manufacturer s warranty of 5-years on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Qualified or Accredited installer. All equipment supplied shall have a manufacturer s 7 year Total Peace of Mind (TPM) warranty on all parts and labour in accordance with Toshiba s warranty and installation guidelines. Equipment to be installed by a Toshiba Accredited (TPM) installer. Design Criteria The air conditioning system(s) shall be designed and equipment selected to conform to the design criteria below ensuring that the heating load is covered by the heat pump (with the additional back up heater if required) at the most extreme outdoor condition of its proposed operation. External Conditions Summer 29 C Winter -5 C Leaving water temp Summer 10 C Winter 45 C DHW temp Summer 10 C Winter 55 C System Specification The system(s) shall be of the Toshiba Estia Inverter Air to Water Heat Pump variety. The system will be capable of both heating and cooling. Each system will use non-ozone depleting HFC refrigerant R410A. The system shall allow a user-driven operating environment to be established where users can directly request their own choice of temperature and on/off control etc. The equipment must be suitable for operating on a Volt, single-phase, 50 Hz supply. The back up heaters for the hydro module will be Volt, single-phase, 50 Hz supply. The back up heaters for the hydro module will be 400 Volt, three-phase, 50 Hz supply. Outdoor Unit(s) Toshiba Model References Max Piping Length Max Lift Max Drop HWS-804H-E 30 m 30 m 30 m

3 HWS-1104H-E 30 m 30 m 30 m HWS-1404H-E 30 m 30 m 30 m HWS-1104H8-E* 30 m 30 m 30 m HWS-1404H8-E* 30 m 30 m 30 m HWS-1604H8-E* 30 m 30 m 30 m *Denotes Three Phase High Temperature Range HWS-P804H-E 30m 30m 30m HWS-P1104H-E 30m 30m 30m The outdoor unit shall be factory assembled, pre-wired, works tested, supplied with a refrigerant pre-charge suitable for 30m of main piping and complete with fully sealed pipe work connections. It shall not be necessary to include oil traps, sight glasses, or external driers. The access panel shall be easily removable for servicing. The condensing unit shall be fitted with its own electrical compartment with all necessary electrical and control components. The casing shall be manufactured from Galvatite steel plate with a Silky Shade (Munsell 1Y ) electrostatic spray finish protected to IP X4 and shall contain the following components: Inverter Driven Twin Rotary Compressor The compressor shall be of the twin rotary type and driven by a High-Speed Calculation Vector Control Inverter, creating seamless capacity control to match the connected indoor unit(s) cooling or heating demand. Fixed speed compressors of any type are not to be used. The compressor shall be factory mounted on springs and shock-absorbing rubber to minimise vibration. Heat Exchanger The heat exchanger shall be factory constructed of rifled copper tubing, mechanically bonded to aluminium fins. The aluminium fin material shall be coated with a hydrophilic coating to prevent corrosion and to assist condensate dispersal. The coil shall have a large surface area to minimize noise and maximise heat transfer. Fan and Motor Each outdoor unit is to be fitted with no more than a single fan. The fan shall be a three-blade, flash-wing, low noise type and shall be both dynamically and statically balanced to produce minimum noise and vibration. The fan shall be directly coupled and driven by a drip proof, permanently lubricated variable speed high-efficiency inverter controlled motor. The outdoor fan speed shall be matched automatically to the energy demands of the heat exchanger. The fan must be able to overcome an external static resistance of 15Pa. Suction Line Accumulator The cylindrical accumulator shall be fabricated from press formed mild steel plates. The accumulator shall have sufficient capacity to prevent any liquid refrigerant from flowing back into the compressor section. Additional Features & Safety Devices: 4-way reversing valve, solenoid valves, pulse-modulating valve, strainer, dryer, service valves with 5/16 gauge ports, thermal protection for compressor, recycling guard timer, over-current protection, compressor suction and discharge temperature sensors, terminals, internal wiring and controls. A pulse-modulating valve will provide capacity control by maintaining suction

4 temperatures of between 1 and 5 K higher than the evaporator inlet temperature additionally, the indoor heat exchanger will be limited to temperatures of no less than 2ºC when cooling. The outdoor unit will automatically defrost in the heating cycle. Indoor Unit Hydro Modules Each indoor unit shall be from Toshiba s Estia Inverter range of Air to water heat pumps and must operate on Volt, single-phase, 50 Hz supply fed from the outdoor unit. For the electrical back up heaters the power supplies shall be Volt, single-phase, 50 Hz supply (HWS-xxxXWHM3 models) or 400 Volt, three phase, 50Hz supply (HWSxxxXWHM6 & XWHM9 models) all fed from a dedicated supply to the hydro module. A separate Volt, single-phase, 50 Hz supply shall be used to feed the DHW tank if used. The heat exchanger shall be made of high grade stainless steel and will be mounted inside the hydro unit. All hydro modules are provided with return water and leaving water temperature sensors. The heat exchanger will be protected against excessive temperatures both low and high. Hydro Module Toshiba Model References: HWS-804XWHM3-E HWS-804XWHT6-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E High Temperature Range HWS-P804XWHM3-E HWS-P804XWHT6-E HWS-P804XWHM9-E HWS-P1104XWHT3-E HWS-P1104XWHM6-E HWS-P1104XWHT9-E The unit will be manufactured from powder coating steel sheet enclosing the heat exchanger, main system primary pump, control electronics, expansion vessel and electrical back up heater. The hot water connections and refrigerant connections are to the bottom of the unit.

5 Domestic Hot Water Tanks Toshiba Model References: HWS-1501CSHM3-UK (150 litre nominal capacity) HWS-2101CSHM3-UK (210 litre nominal capacity) HWS-3001CSHM3-UK (300 litre nominal capacity) The tanks will be manufactured from powder coated stainless steel and be available in three sizes as above. Each tank will have its own 3kW electrical immersion heater, hot water sensor and controls to link it to the Toshiba hydro unit. Each tank will be supplied with cold water combination valve (to meet UK water regulations), factory fitted temperature / pressure relief valve, T&P valve insulation and housing, expansion vessel and mounting bracket, tundish, compression nuts and olives and heater key spanner. Refrigerant Pipe-Work All pipe-work shall be manufactured using de-oxidised, refrigerant quality copper to BS EN 1057:1996, and must be heat-treated as follows: 9.5mm (3/48 ) OD to 15.9mm (5/8 ) OD - Soft, Half Hard or Hard Tempered The length/height difference parameters and outside diameter of all piping is to be in accordance with the appropriate Toshiba manuals. Interconnecting controls Wiring The nominated installer shall be responsible for the following interconnecting controls wiring: 3-core & earth = Outdoor unit to Indoor Unit (1, 2, 3 & E) 3-core = DHW Tank to Indoor Unit (1, 2 & E) All electrical wiring, bonding and earthing shall be in accordance with the current edition of BS 7671: 2008 (IEE Wiring Regulations 17 th Edition). The voltages stated are EC harmonised voltages, but the equipment shall be suitable for volts single phase. Controls The Toshiba Estia Air to Water Heat Pump(s) shall be complete with the Toshiba in-built hard wired controller, fitted to the front of the hydro unit.

6 The remote controller(s) shall be surface mounted and hard wired to the hydro unit(s) and will provide the user with local individual control of the hot water temperatures. The controller shall be manufactured in ABS plastic with a liquid crystal display (LCD). The controller shall enable the user to interrogate the system and display an alphanumeric fault code in the event of system malfunction. The controller shall have the capability of accessing all the system function codes for customising the settings and operation of the system. The controller shall be able to provide control or indicate status of the following functions: Start/stop. Operating mode (autocurve, cool, heat). Temperature set point 2 zone temperature control Test run (heating & cooling). Schedule 7 day timer operation (Operation time, start/stop, temp setting & restriction) Minimum and maximum temperature settings in each mode Auto-restart. Sensor data available from all associated indoor and outdoor units Night operation setting for noise and temperature set back Hot water boost function Frost protection DHW anti bacteria function

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD

More information

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q *** PRODUCT BULLETIN Estia Air to Water Heat Pump 5 Series w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q4 2017 *** are pleased to announce the production of the NEW Estia

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types Quick Reference Air to Water Heat Pump Series 4 Lot Standard & Powerful Types Estia Series 4 Standard Type Models: Hydro unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-404XWHM3-E HWS-404XWHT6-E

More information

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E AIR TO WATER HEAT PUMP Hydro Unit Model name: HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E English Thank you very much for purchasing TOSHIBA Air to Water

More information

Do you want a versatile solution

Do you want a versatile solution Do you want a versatile solution to make significant savings? ESTIA TOSHIBA AIR CONDITIONING RESIDENTIAL HEATING AIR-TO-WATER HEAT PUMP ESTIA hatever you need ESTIA TO MAKE SIGNIFICANT SAVINGS Toshiba

More information

TOSHIBA AIR CONDITIONING. TOSHIBA Super Heat Recovery Multi System Standard Specification

TOSHIBA AIR CONDITIONING. TOSHIBA Super Heat Recovery Multi System Standard Specification Introduction The following specification describes the Toshiba 3-Pipe Super Heat Recovery Multi air conditioning system(s) to be installed at the below site: (ADD SITE NAME) The system(s) shall consist

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

Air to water Heat Pump System

Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

Tel: Heronhill - For all your Toshiba heating and cooling requirements   Air to water Heat Pump System Air to water Heat Pump System 2 The heating and cooling systems of the future! A step in the right direction of reducing pollution and CO₂ emissions The increase of CO₂ and other green house gases is a

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE. Kaden Ducted Air Conditioners Creating the ideal climate in different rooms throughout your home is essential for your family s comfort. Whether it s a

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

Air to Water Heat Pump

Air to Water Heat Pump E15-381 Engineering Data Book Air to Water Heat Pump Hydro Unit HWS-804XWHM3-E1 HWS-804XWHT6-E1 HWS-804XWHT9-E1 HWS-1404XWHM3-E1 HWS-1404XWHT6-E1 HWS-1404XWHT9-E1 Outdoor Unit 8 kw 11/14/16 kw HWS-804H-E1

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS Aurora Wall Split Systems. Built for one of the harshest climates on Earth. Aurora Wall Split Systems The leading Australian owned air conditioning

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

Installation Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Installation Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E AIR TO WATER HEAT PUMP Hydro Unit Model name: HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E English Please read this carefully before installing the Air to

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 198 saw Advanced Australia Fair become

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

Refrigeration Technology in Building Services Engineering

Refrigeration Technology in Building Services Engineering Unit 70: Unit code: T/600/0459 QCF Level: 3 Credit value: 10 Guided learning hours: 60 Unit aim Refrigeration Technology in Building Services Engineering This unit develops an understanding of the principles,

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

Condensing Units CUS 15-60

Condensing Units CUS 15-60 Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

TOSHIBA Super Heat Recovery Multi Enhanced System Standard Specification

TOSHIBA Super Heat Recovery Multi Enhanced System Standard Specification Introduction The following specification describes the Toshiba 3-Pipe Super Heat Recovery Multi air conditioning system e (SHRMe) to be installed at the site below: The system(s) shall consist of the following

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz 30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB

More information

Samsung EHS Heat Pump Test

Samsung EHS Heat Pump Test Samsung EHS Heat Pump Test The following questionnaire is designed for installers who have experience with heat pumps, are currently MCS accredited, and who want to fast track their Samsung accreditation

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw. 1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing

More information

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool Air Conditioning Product Brochure 2015/2016 Classic Series Hi-Wall Split Systems Everyday Cool 3 Everyday Innovation We design with you in mind. You ll find that Haier Air Conditioning units are quiet,

More information

recooler HP EQKR HEAT PUMP

recooler HP EQKR HEAT PUMP AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump PRODUCT SELECTION DATA Monobloc inverter Compact, reliable and efficient More than a Heat Pump Reversible Air to Water Heat Pump 0AW CARRIER participates in the ECP programme for LCP/HP Check ongoing validity

More information

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

Air to Water Heat Pump

Air to Water Heat Pump E7- Air to Water Heat Pump Hydro Unit HWS-55XWHM-E HWS-805XWHM-E HWS-805XWHT6-E HWS-805XWHT9-E HWS-05XWHM-E HWS-05XWHT6-E HWS-05XWHT9-E HWS-P805XWHM-E HWS-P805XWHT6-E HWS-P805XWHT9-E HWS-P05XWHM-E HWS-P05XWHT6-E

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

GENERAL INFORMATIONS

GENERAL INFORMATIONS GENERAL INFORMATIONS Devices only operate in cooling mode. Enviromental-friendly R407c coolant is utilized in standard products. The system can be created with various coolants depending on the water temperature

More information

50A KP 70A KP 90A KP 120A KP 150A KP 210A

50A KP 70A KP 90A KP 120A KP 150A KP 210A DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

Frequently Asked Questions

Frequently Asked Questions Air Source Heat Pumps Frequently Asked Questions Heating that doesn t cost the earth What are the benefits of Air Source Heat Pumps over Ground Source Heat Pumps? There are a number of benefits when using

More information

we care about Better Air

we care about Better Air 3 Technologies & Useful Features INVERTER G2KCV Toshiba IAQ Pre-filter Filters Toshiba Airconditioning, we care about Better Air Our products comply with RoHS Regulations, ensuring no restricted substances

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron. Whole of Home Ducted comfort, for when space is at a premium. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

AQUAHEAT ADVANCE SPLIT

AQUAHEAT ADVANCE SPLIT AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /

More information

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw Ducted Split System Air Conditioner Technical Data ISD 87KYX / OSA 87RKSH SEPARABLE INDOOR UNIT Optional SAT-3 or TZT-100 Room Temperature Controller High Efficiency EC Motor Extra Long Life Epoxy Coated

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM Eaton-Williams Ltd APPLICATION MANUAL ICC COOLING STORAGE UNIT ICC/ICU SYSTEM Eaton-Williams Ltd Station Road Edenbridge Kent TN8 6EG Tel: +44 (0)1732 866066 Fax +44(0)1732 866653 www.eaton-williams.com

More information

500 EX Fusion Compressor Series

500 EX Fusion Compressor Series 500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications

More information

WHY A MHI HEAT PUMP?

WHY A MHI HEAT PUMP? HYDROLUTION HEATING HOT SANITARY WHY A MHI HEAT PUMP? Mitsubishi Heavy Industries Thermal Systems air to water heat pump is a complete modern system for heating, cooling and producing hot sanitary water

More information