TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc
|
|
- Tiffany Summers
- 6 years ago
- Views:
Transcription
1 TOP 29 ENCLOSURE COOLING QUESTIONS ASKED BY PROSPECTIVE THERMAL EDGE CUSTOMERS 2015 Thermal Edge, Inc
2 About the Authors LISA BAKER Lisa Baker is the Inside Sales Manager. When you need help determining the best cooling solution for your application, she can size your application and quote a recommended cooling solution. With eight years experience in solving customer cooling needs, Lisa can recommend solutions for difficult environments such as hazardous location or corrosive applications, vibration issues, or public/remote applications needing secure enclosures. For replacing existing units, she can cross reference part numbers and size for mounting plates. She will provide formal quotes, literature, drawings - everything you need to make a fact based decision for important enclosure cooling solutions. NOEL FERNANDEZ Noel Fernandez is a Technical Support Manager with Thermal Edge Inc. He provides resources to customers, ensuring any questions they have about Thermal Edge products are answered accurately. Mr. Fernandez has more than 8 years experience in HVAC mechanical operational performance with advanced knowledge of the practices and procedures for HVAC troubleshooting, returns, and warranty claims. 2
3 Introduction The early 1960s witnessed the advent of the first air conditioners and heat exchangers for electrical equipment in enclosures. However, the importance of enclosure cooling solutions has not been fully understood until recently. Modern electrical devices not only are more powerful and efficient, but also dissipate more of the heat that can raise the enclosure temperature by a significant amount. Equipment manufacturers specify maximum allowable temperatures for their products above which performance, reliability, and lifespan are deteriorated. The emphasis on the use of enclosure cooling solutions for electrical equipment has encouraged customers to come forward with questions about choosing the best fit for their applications. Here are some of the top questions that Thermal Edge is asked about enclosure air conditioners by prospective customers: 3
4 Pre-Sales Questions HOW MUCH DOES AN ENCLOSURE AIR CONDITIONER COST? The cost of an enclosure air conditioner varies based on its cooling capacity, NEMA type, voltage specifications, and the design profile. It can range from $1,500 for a 120V, 1,000 BTUH air conditioner designed for a NEMA 12 enclosure, to $8,000 for a 480V, 20,000 BTUH model designed for a NEMA 4X enclosure. Options and accessories for specific applications can be added to the enclosure air conditioner at extra cost. WHERE CAN I PURCHASE THERMAL EDGE ENCLOSURE AIR CONDITIONERS? Thermal Edge sells enclosure air conditioners and other enclosure cooling solutions directly to customers as well as through several national and independent distributors across the US. The Thermal Edge website can provide more information on how to contact a technical sales representative to size your enclosure air conditioner for the project s application. HOW DO THE UNIT FEATURES AND FUNCTIONALITY COMPARE WITH COMPETITORS PRODUCTS? Thermal Edge air conditioners have been designed with energy efficiency and smaller footprint in mind, therefore, are smaller and consume from 30 to 50 percent less energy than other units of comparable cooling capacity. Thermal Edge units also include a condensate evaporation system, a digital controller, and a thermal expansion valve as part of standard designs, whereas most competitors offer these as paid options. 4 5 WHAT ARE THE DIMENSIONS AND WEIGHT OF AN ENCLOSURE AIR CONDITIONER? The size of an enclosure air conditioner depends on its cooling capacity. The smallest air conditioner with 1,000 BTUH capacity fits in a 17 x 7 x 7 space; on the other end of the spectrum, Thermal Edge offers a 20,000 BTUH unit that fits in a space of 65.7 x 23 x 15. The former weighs 30 pounds; the latter 320. HOW SHOULD THE AIR CONDITIONER BE SIZED? Sizing an air conditioner requires the calculation of heat loads in the enclosure due to equipment, solar heat gain, heat due to ambient temperature, and heat from other equipment in the vicinity. The design should take into consideration the size of the enclosure, the ambient temperature, enclosure material, color and insulation, and air flow conditions in the location of the enclosure. The BTUH calculator from Thermal Edge can simplify the process of sizing the air conditioner for your application. Thermal Edge offers air conditioners in the range of 1,000 to 20,000 BTUH, designed for use with various applications. 4
5 Application-Specific Questions WILL THE AIR CONDITIONER CORRODE WHEN INSTALLED IN A POTENTIALLY HARMFUL ENVIRONMENT? Thermal Edge air conditioners are provided with different corrosion protection options for use in potentially harmful locations. The AXX and BXX packages are available for use with NEMA types 12, 4 and 4X and offer protection for the condenser and evaporator coils against acids, solvents, salt, and chemicals. The CXX option is a more comprehensive corrosion protection package that covers all the coils and the brazed fittings. Selection of stainless steel (NEMA type 4X) models is strongly advised. DOES THERMAL EDGE PRODUCE AIR CONDITIONERS FOR USE IN HAZARDOUS LOCATIONS? This is all going to change when we get ATEX and IECeX certification later this year! Thermal Edge makes enclosure air conditioners specifically for hazardous duty. They are designed for exposure to Class 1, Division 2, and Groups B, C, and D. The design conforms to the standard requirements of ANSI/NFPA 70, NEC and CAN/CSA-C22.1, and CEC, and exceeds the specifications of Zone 2 T5 rating. These systems are available with cooling capacities from 2,000 to 20,000 BTUH. WHAT ARE THE OPTIONS FOR AN ENCLOSURE THAT IS SUBJECT TO FREQUENT WASHDOWN (WASH-DOWN) OR SPRAYING? In washdown (wash-down) and spraying situations with high-pressure hoses and water or chemical solutions, Thermal Edge provides enclosure air conditioners with a seam-welded housings for use with a NEMA 4 or 4X enclosure. The design of the housings minimizes accumulation of dust and mold; sloped housing roofs prevent liquid accumulations as well. Enclosure air conditioners used in food processing plants can include filter hoods for their standard filters that offer additional protection against washdown (wash-down). Rugged stainless steel filters are also options designed to work in 9 10 food processing plants where frequent washdowns ) wash-down) and spraying happen; these filters have extended capacity and are superior to aluminum filters in their ability to withstand chlorine. WOULD THE AC STILL BE ABLE TO FUNCTION OPTIMALLY IF THE ENVIRONMENT HAS A HIGH LEVEL OF POLLUTANTS (DUST AND PARTICULATE MATTER)? Many of Thermal Edge s products are being used in environments that are subject to dust from coal, wood, flour, and other contaminants. The products are equipped with optional 2-inch deep pleated 250-micron filters that protect the condenser coil and fan from potentially damaging particulate matter with 94 percent efficiency. The 2-inch-filters have 400 percent more capacity than standard filters so they do not have to be serviced as often. WHAT KIND OF REFRIGERANT IS USED IN THE AC? IS IT TOXIC? WHAT ARE THE IMPLICATIONS IF IT LEAKS, ESPECIALLY IN A FOOD PROCESSING PLANT? Different models of enclosure air conditioners use different refrigerants; the CS and NE series use R134a and R422d, and the HC series uses R438a. Environmental Protection Agency reports state that the toxicity for all three refrigerants is very low. There have been no recorded effects of exposure to these chemicals in trace amounts to humans and animals. Because refrigerant vapors are lighter than air, there is little chance that they mix with food. Material safety data sheets (MSDS) are available with procedures for handling or working with the refrigerants in a safe manner, and include information such as physical data (melting point, boiling point, flash point, etc.), toxicity, health effects, first aid, reactivity, storage, disposal, protective equipment, and spill-handling procedures. 5
6 Application-Specific Questions (cont.) HOW CAN THERMAL EDGE PRODUCTS DEAL WITH TEMPERATURE EXTREMES? The Ambient package options for Thermal Edge air conditioners protect the compressor and optimize the system for operation at temperature extremes (below 50 F and above 125 F). The Low Ambient Temperature package applies heat within the compressor and protects it from damage due to stalling or starting from a non-optimal lowtemperature state. The condenser fan switches off to build up the heat inside the unit, thus allowing rapid warm-up to optimal conditions. The High Ambient Temperature package optimizes the system to perform efficiently at high ambient conditions. The standard maximum ambient temperature for operation is 125 or 131 F, but most models can be customized to operate at 140 F. HOW CAN A UNIT BE PROTECTED AGAINST VANDALISM? Outdoor applications are prone to theft and vandalism. Thermal Edge has a range of enclosure air conditioner options designed for secure applications. The remote controller option relocates the digital controller from the front of the air conditioner to inside the enclosure. The controller is attached to an eight foot cable and has a universal mounting bracket for easy installation. Security filter frames are available with or without protective louvers that require removal of four screws to access the filters, instead of the standard sliding filter frames WHAT STEPS CAN BE TAKEN TO PROTECT AIR CONDITIONERS AGAINST VIBRATION? Thermal Edge provides easy solutions to protect their air conditioners in applications subject to vibrations. The Vibration package replaces vulnerable refrigerant lines with flexible shockabsorbing lines; rubber bushings are installed to reduce stress from vibration on copper joints. High-quality silver solder is used in brazed joints. HOW DOES THERMAL EDGE ADDRESS CRITICAL APPLICATIONS IN WHICH FAILURE IS NOT AN OPTION? The Redundant System option is available for applications that are critical to a business. Two self-contained air conditioners share the cooling load for the application and alternate operation so that efficient cooling is provided. In the event of failure of one air conditioner, the cooling load will be borne by the remaining unit. In the event extra cooling is needed, both air conditioners will operate. 6
7 Installation Questions HOW DOES THE AIR CONDITIONER MOUNT ON THE ENCLOSURE? HOW EASY OR DIFFICULT IS THE MOUNTING PROCESS? The air conditioner package contains a template that can be used to cut the required holes in the enclosure. After the mounting position of the AC is determined and the holes are cut, an insulation gasket must be installed on the air conditioner. The air conditioner can then be hung on the enclosure cutout by the easy-hang tabs. Fasteners are provided with the package to attach the AC to the enclosure. The process is straightforward and can be accomplished with basic tools. CAN THERMAL EDGE AIR CONDITIONERS REPLACE OTHER AIR CONDITIONERS WITHOUT MAKING DESIGN CHANGES TO THE ENCLOSURE? The Universal Mounting Plate accessory allows mounting of Thermal Edge products to the enclosure to replace any existing enclosure air conditioner. The plate is precut for mounting specific models on NEMA 12, 4 or 4X enclosures and can be used as a template to adjust the existing cutouts on the enclosure. WHAT ARE THE STANDARD COMPONENTS THAT ARE PROVIDED WITH THE UNIT FOR INSTALLATION? Enclosure air conditioners are provided with templates that are used to make cutouts in the enclosure for their mounting and installation. Gaskets are provided to ensure an airtight, closed loop seal around the periphery of the cutout. The unit can be hung from easy-hang tabs on the air conditioner while the air conditioner is attached to the enclosure with the hardware supplied WHAT DO THE DIGITAL CONTROLLER ALARM CODES MEAN, AND HOW CAN THE SETTINGS BE CHANGED? The digital controller has several alarm codes to monitor the status of the air conditioner. P1 and P2 indicate enclosure probe and condenser probe failure. HA and LA are the maximum temperature and minimum temperature alarms. HA2 and LA2 are high and low temperature alarms for the condenser. CA indicates low refrigerant pressure in the evaporator coil. The settings for all these alarms can be changed from the programming interface of the digital controller. See the user manuals on the Thermal Edge web site. WHAT IS THE OPTIMAL TEMPERATURE SETTING FOR THE AIR CONDITIONER? The optimal temperature setting for an enclosure depends purely on the nature of the electrical equipment inside it. Variable Frequency Drives are designed for operation below 104 F; conventional energy storage devices such as Li-Ion batteries require an operating temperature of about 86 F. 7
8 Temperature Control Questions 20 HOW EASILY CAN THE AIR CONDITIONER BE WIRED TO THE POWER SUPPLY? IS IT ONE-PHASE OR THREE-PHASE? Thermal Edge standard air conditioners are supplied for 120V, 230V, and 480V single-phase 60 Hz power. Each unit is provided with an easy-connection power terminal block. See the user manuals on the Thermal Edge web site. Standard Features Questions DOES THE AIR CONDITIONER DRIP WATER? No. The condensate management system is so efficient in Thermal Edge air conditioners that drain pipes are unnecessary as long as the enclosure remains closed. The Thermal Edge system also increases the air conditioner efficiency by using the hot refrigerant tubing from the compressor to boil off the water. WHAT ARE THE FILTERS MADE OUT OF? ARE THEY CORROSION-RESISTANT? The standard filters on Thermal Edge air conditioners are made out of aluminum and offer good resistance to corrosion. Options such as filter shrouds can protect the filters against direct ingress of water and chemicals from wash-down or spraying. Stainless steel filters, available as options instead of standard filters, offer better resistance to corrosion against chlorine, bleaching agents, and other heavy chemicals. Furthermore, they require less maintenance with their extended filter capacity HOW OFTEN MUST THE FILTERS BE REPLACED? DO THE FILTERS COME WITH OPTIONS? Clean filters are an essential prerequisite to efficient air conditioner operation and performance. Dirty and clogged filters can interfere with normal operation and even damage the system. The frequency with which filters must be washed or replaced depends on the environment where the enclosure is located. The lifespan of these filters depends on the methods used for washing and cleaning. For dusty and polluted environments, Thermal Edge offers two inch pleated filters, with 400 percent greater capacity than flat filters that increase the time between filter maintenance. WHAT ARE THE IMPLICATIONS OF HIGH ENVIRONMENTAL HUMIDITY AND DISPERSED OIL ON THE ENCLOSURE AIR CONDITIONER? Closed-loop cooling systems are capable of handling high humidity and dispersed oil in the air by virtue of their design. The efficient condensate evaporation system in Thermal Edge air conditioners removes all the moisture in the enclosure, thus eliminating risk of exposure of the electrical equipment to condensation. 8
9 Standard Features Questions (cont.) HOW RELIABLE ARE THERMAL EDGE AIR CONDITIONERS? Enclosure air conditioners are industrial appliances consisting of electromechanical components that must be cleaned, maintained, and serviced periodically for reliable operation. Thermal Edge products have been designed with quality, energy efficiency, and footprint in mind. The safety features and fail-safe design make the products extremely reliable in all applications. HOW LONG DOES AN AC LAST IN FOOD PROCESSING AND WASTEWATER TREATMENT FACILITIES? Thermal Edge designs its products for use with many applications, including food processing and wastewater treatment facilities. NEMA type 4X units made from 304 stainless steel with electrostatic epoxy-coated condenser coils. Additional options include high-capacity filters, filter hoods, and integrated heaters. The lifespan of ACs in these applications varies based on the environment, frequency of use, and extent of service and maintenance. 27 IS THERE A WAY TO GET ALARM OPTIONS FOR THE AIR CONDITIONERS? There are different alarm options for Thermal Edge air conditioners. The Dry Contact option provides for an easily programmable, early hightemperature alarm warning that can be seen or heard at a distance. The Remote Control and Monitor options make it easy for all programming to be done remotely and the alarms to be transmitted through Ethernet/IP, or Modbus RTU or TCP/IP Ethernet networks. 9
10 After-Sales Questions WHAT IS THERMAL EDGE S WARRANTY? Thermal Edge offers products with defect-free workmanship, materials, and components. The warranty period is one year from the date of shipment, provided the operating conditions of the air conditioner are within the limits specified on the nameplate (ambient temperature, voltage and frequency specifications, cooling load) and compliance to installation and maintenance instructions. Extended warranties are also available. DOES THERMAL EDGE OFFER PRE-SALE SUPPORT FOR THEIR CUSTOMERS? First-time buyers may find the sizing of an enclosure air conditioner for their applications tricky. For this reason, Thermal Edge offers its customers a BTUH calculator that gathers information about their applications and helps them size a suitable air conditioner. Furthermore, Thermal Edge gives customers the option to speak with an experienced technical sales team that can find the best solution for their requirements. Multiple guides are available in the Resources section of the website that simplify the process of choosing an enclosure AC manufacturer and buying an efficient product. Do you have any additional questions about Thermal Edge products and your cooling needs? If you need help selecting the right temperature control solution for your application, talk to the professionals at Thermal Edge. Our experts will work with you from beginning to end to ensure that you have the most cost-effective solution for your application. We also work with engineers who design electrical enclosures to help determine the right temperature control solution early in the design process. Get in touch with us today to review case studies that are similar to your application, review product literature, or schedule a consultation. Get a Quote For an Enclosure Cooling System Get a Quote Now > 10
32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4
TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4 ENVIRONMENTAL ASPECTS.. 6 SPECIAL REQUIREMENTS.. 8 MANUFACTURER CONSIDERATIONS.. 8 SELECTING AN ENCLOSURE AIR CONDITIONER.... 9 2 Although the selection
More informationTHE ULTIMATE GUIDE TO ENCLOSURE COOLING FOR WATER TREATMENT. The Ultimate Guide to Enclosure Cooling for Water Treatment
THE ULTIMATE GUIDE TO ENCLOSURE COOLING FOR WATER TREATMENT 2016 Thermal Edge, Inc. 888.580.0202 CONTENTS Introduction... 1 Why Enclosure Cooling is Important in Water Treatment... 2 How to Select the
More informationENCLOSURE COOLING. Glossary
ENCLOSURE COOLING Glossary Contents INTRODUCTION... 3 TYPES OF COOLING EQUIPMENT... 4 COOLING EQUIPMENT COMPONENTS... 5 ESSENTIAL COOLING S... 8 COOLING EQUIPMENT ACCESSORIES... 13 EQUIPMENT THAT NEEDS
More informationRV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER
RV Products Division INSTALLATION INSTRUCTIONS FOR 46413 SERIES PACKAGE AIR CONDITIONER 1. WARNINGS IMPORTANT NOTICE These instructions are for the use of qualified individuals specially trained and experienced
More informationTemperature Control for
Temperature Control for Electrical Enclosures: Why You Can t Ignore It Introduction Electrical equipment is almost always specified by manufacturers for operation within an optimal temperature range in
More informationKOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET
KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET TYPE 4 INDOOR OUTDOOR TYPE 4 480 VOLT INDOOR OUTDOOR TYPE 12, 3R AND 4 (4X OPTIONAL) SLIMKOOL Guardian/ GuardianX Series 4 Rating Maintained ( 4X Rating
More informationVA G 052 S
763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY
More informationVA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners
V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures
More informationVA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners
763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000
More informationGP SERIES Packaged Chillers
Material Handling Process Cooling Temperature Control Size Reduction Temperature Control Process Cooling Material Handling Size Reduction GP SERIES Packaged Chillers Precision Comprehensive Engineered
More informationDelta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers
Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers What Sets Delta T Systems Chillers Apart? Variable Speed Compressor The compressors used
More informationGuardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners. Air Conditioners:
Air Conditioners:» Advantage Guardian Guardian 480 Intrepid Mini Profile Profile 480 Rack Mount Top Mount Traditional TrimLine Water-Cooled Guardian/GuardianX Series NEMA 4 or 4X Rated Air Conditioners
More informationGuide To Troubleshooting INEFFICIENT COOLING FANS
Guide To Troubleshooting INEFFICIENT COOLING FANS TABLE OF CONTENTS Introduction Enclosure Cooling Basics Key Attributes of Enclosure Cooling Symptoms of Poor Enclosure Cooling Typical Cooling Fan Problems
More informationTHE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS
THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide
More information5736 N. Michigan Road Indianapolis, IN 46228
763.576.3200 SPEC-00728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 BTU/Hr. Watt G52 / BTU/Hr. 2300/3500 Watt
More information5736 N. Michigan Road Indianapolis, IN 46228
763.576.32 SPEC-728 H763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt
More informationCS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)
CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System
More informationThe Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors
by The Leading Enterprise Internet of Things Solution DUCT TEMPERATURE Wireless Duct Temperature Sensors General Description The ALTA Wireless Duct Temperature Sensor uses an NTC thermistor with 8 ft.
More informationG /6000 BTU/Hr. 1172/1758 Watt
SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient AirFlow INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File
More informationThermal Management INDEX. Management. Thermal TM-1
Heat builds up rapidly in enclosed environments, compromising the performance and life span of equipment. Like insurance for your electronics, effective thermal management maximizes the efficiency and
More informationKNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER
More informationSECTION Free/Available Chlorine Analysis System
SECTION 40 75 21 Free/Available Chlorine Analysis System PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor system for free chlorine measurement for disinfection purposes in drinking water,
More informationKPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER
More informationService Parts for RMR Wall-Mount Enclosures
Door Kits for RMR Wall-Mount Enclosures Replacement doors for RMR Wall-Mount Enclosures are removable and can be easily replaced if a door is damaged. Order latch separately. Several options are available:
More informationFULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY
C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial
More informationCondensing Unit Installation and Operating Instructions
Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationRev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4
More informationEIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S
EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 1500 Btu MODEL # S AAC-145-T-E AAC-145-4XT-E AAC-145-T-E-HC AAC-145-4XT-E-HC AAC-145-XXXXX Cooling Solutions for
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM
SECTION 23 81 06 - PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes equipment types that contain all the components of the refrigeration process within
More informationPDF Created with deskpdf PDF Writer - Trial ::
Instruction Manual Index Introduction Uncrating and Checking for Damage Locating Your Unit Installation Fill Tank Process Connections Pre Startup Startup Sequence Trouble Shooting Chart Operating Lights
More informationNOREN Products. Compact Cabinet Coolers
NOREN Products Back to INTRODUCTION Inc. 3 Noren Products Inc. produces a broad range of heat transfer devices incorporating heat pipes. Several of the company's products are widely recognized by their
More informationPROAIR Harsh Environment/Wash Down Air Conditioners
PH FX ( Product Overview McLean Cooling Technology: Air Conditioners: Harsh Environment/Wash Down Air Conditioners CR23 CR23st CR43st CR29 102 Product Overview : The ultimate in protective cooling for
More informationADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationFlexible & Innovative. Cooling Solutions
Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly
More informationWireless Duct Temperature Sensor
The Leader in Low-Cost, Remote Monitoring Solutions Wireless Duct Temperature Sensor General Description The Wireless Duct Temperature Sensor uses an NTC thermistor with 8 ft. lead wires to accurately
More informationNOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016
NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-6149 FAX www.norlake.com Kold Locker Walk-ins Standard Model Coolers
More informationSteam Humidification Light Commercial Applications. Better technology means better business.
Steam Humidification Light Commercial Applications Better technology means better business. Aprilaire Steam Humidifiers are built to last. Through extensive research and over 50 years expertise in humidification
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 060 March 05 Supersedes November 0 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0 kw
More informationWireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation
by The Leading Enterprise Internet of Things Solution WATER DETECT Wireless Water Detection Sensors General Description The ALTA Wireless Water Detection Sensor detects the presence or non-presence of
More informationIf you have any questions, please feel free to contact me at (405) or via at
Marketing News M-183-2007 Date: August 7, 2007 To: All Branch Managers, Branch Sales and Service Managers, Distributor Principals, Distributor Sales and Service Managers, Regional Sales Managers and Regional
More informationUPFLOW/DOWNFLOW COILS
UPFLOW/DOWNFLOW COILS INSTALLATION INSTRUCTIONS 1. Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is
More informationMERIT Series R-410A - Upflow / Horizontal
PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UH (-0) MERIT Series R-0A - Upflow / Horizontal Bulletin No. 0770 January 07 Supersedes August 06 Nominal Capacity -.5 to 5 Tons Optional Electric Heat -.5 to 0
More informationAA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL
AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions
More informationCO2 TRANSCRITICAL BOOSTER SYSTEMS
CO2 TRANSCRITICAL BOOSTER SYSTEMS William Katz Sr. Technical Writer Hillphoenix 2016 Gees Mill Road Conyers, GA 30013 Tel: 678-613-9364 Email: william.katz@hillphoenix.com Refrigeration systems for supermarkets
More informationXSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1
Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L
INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com, or use the Technical Documents QR code below. Technical Documents
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner
COMPACT SERIES HORIZONTAL TOP MOUNT KA4C4HTL with Serial Numbers up to and including H17A2431 K2A4CHTL with Serial Numbers up to and including M17A 3957 Keep This Manual With Air Conditioner Find additional
More informationCavitator Ultrasonic Cleaners
Cavitator Ultrasonic Cleaners Instruction Manual (for model # 18G) 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com
More informationD-TEK Select. Refrigerant Leak Detector
O P E R A T I N G M A N U A L D-TEK Select Refrigerant Leak Detector DECLARATION OF CONFORMITY This is to certify that this equipment, designed and manufactured by INFICON Inc., Two Technology Place, East
More informationKNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHX2 SERIES NEMA /X AIR-TO-AIR HEAT EXCHANGERS
More informationInnovative Design, Performance, & Serviceability
Innovative Design, Performance, & Serviceability AAON Experience For over 15 years AAON has manufactured Water-Source Heat Pump (WSHP) Rooftop Units, Vertical Self-Contained Units, and Modular Air Handling
More informationRefrigerant air dryers. FD series ( l/s, cfm)
Refrigerant air dryers FD series (6-4000 l/s, 13-8480 cfm) Why dry your compressed air? Compressed air is used in a wide variety of industrial applications. Wherever it is used, compressed air must be
More informationWebinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers
Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers Q: Can you explain how a swamp cooler works and/or is different? A swamp
More informationAQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller
AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller INSTALLATION & OPERATING INSTRUCTIONS Effective 8-19-15 Thank you for purchasing an Aqua logic chiller. It has been designed and built to
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner WATER-COOLED RACK MOUNTED
WATER-COOLED RACK MOUNTED Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ AND
More informationBlade Series Heat Exchanger Operation and Installation
Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information
More informationSPECTRACOOL INDOOR/OUTDOOR
SPEC-728 E SEALED ENCLOSURE AIR CONDITIONERS SEALED ENCLOSURE AIR CONDITIONERS SPECTRACOOL INDOOR/OUTDOOR G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient
More informationOwner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER
MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER Owner s Manual Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 IMPORTANT NOTE: Read this manual carefully before installing
More informationTOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes
TOCOS Trimmer Potentiometers are designed and manufactured with emphasis on dependability and costeffectiveness. For reliable performance and general safety, follow these guidelines and precautions for
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner
Keep This Manual With Air Conditioner MICRO-MINI* SUPER-MINI NARROW-MINI *For Micro-Mini units with Serial Numbers up to A17A0030 Find additional information on this model at kooltronic.com or use the
More informationOwner s Manual Super-Slim Four-Way Cassette
CASSETTE- TYPE AIR CONDITIONER Owner s Manual Super-Slim Four-Way Cassette IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this
More informationPoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS
PoolPak MPK Series Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS PoolPak.com The PoolPak MPK Series Built using the PoolPak Proven Approach SM, the MPK Series
More informationCondensing Unit Installation and Operating Instructions
Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...
More informationOWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA
OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump
More informationThe Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors
Wireless Dry Contact Sensors by The Leading Enterprise Internet of Things Solution General Description ALTA wireless dry contact sensors can be used to detect contact between two wired contact points,
More informationGG-R REFRIGERANT SENSOR. Installation and Operation Manual
GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner
TRIMLINE NP28 SERIES KA4C4NP28L with Serial Numbers up to and including L16A3713 K2A4C4NP28L with Serial Numbers up to and including E16A1554 Keep This Manual With Air Conditioner Find additional information
More informationMERIT SERIES Up Flow / Horizontal
A I R H A N D L E R S CB26UH / CBX26UH MERIT SERIES Up Flow / Horizontal E N G I N E E R I N G D A T A Bulletin No. 210429 December 2006 Supersedes November 2006 Nominal Capacity 1.5 to 5 Tons Optional
More informationGENESIS Indoor Air Conditioners
Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners
More informationKSD-35 DR11 KUE-35 DVN11
FLOOR-STANDING TYPE AIR CONDITIONER Owner s Manual Floor-Standing Type KSD-35 DR11 KUE-35 DVN11 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit.
More informationSB Series Brazed Plate Heat Exchanger Installation Manual
SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual
More informationWATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00
I&M NUMBER: 316-42-8-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to
More informationUsing Portable Spot Air Conditioners in Industrial Applications
Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRADITIONAL SERIES P47 P52 P59
TRADITIONAL SERIES P47 P52 P59 Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com, or use the Technical Documents QR code below. Technical Documents P47 Technical
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner DP SERIES K_A4C5DP33L
DP SERIES K_A4C5DP33L Keep This Manual With Air Conditioner Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents AIR CONDITIONER
More informationCabinet Cooler Systems
Cooler Systems Cooler Systems Stop electronic control downtime due to heat, dirt, and moisture! maintain NEMA 4, 4X, and 12 integrity. All are and compliant! What is an EXAIR Cooler System? A low cost,
More informationUp to 60 Pint Commercial Grade DEHUMIDIFIER
OWNER S MANUAL Up to 60 Pint Commercial Grade DEHUMIDIFIER Product #700834 IMPORTANT: After unpacking (or accidental tip-over) allow dehumidifier to stand upright for 20 minutes before starting. Contents
More informationOutdoor and Indoor Electric Refrigerator Model COAR
Outdoor and Indoor Electric Refrigerator Model COAR USER S MANUAL COAR PLEASE READ THE MANUAL THOROUGHLY PRIOR TO EQUIPMENT SET-UP, OPERATION AND MAINTENANCE. - 1 - INSTALLATION IMPORTANT!!! PLEASE READ
More informationSECTION AIR COMPRESSORS AND ACCESSORIES
PART 1 GENERAL 1.01 WORK INCLUDED SECTION 11370 AIR COMPRESSORS AND ACCESSORIES A. This specification includes air compressors with air dryers. B. Furnish, install, start-up, and test air compressors and
More informationKPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER
More informationKNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES
ADVANTAGE RP55 SERIES Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY
More informationIncreased Performance Higher System Efficiency Low Refrigerant Charge Compact Design
A Wholly Owned Subsidiary of EVAPCO ADVANCED MicroChannel T E C H N O L O G Y Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design MADE IN THE USA MicroChannel Heat Excha
More informationEXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series
EXTERNALLY HEATED DESICCANT AIR DRYERS GEHD Series GARDNER DENVER GEHD DESICCANT AIR DRYERS Why Dry Compressed Air? Compressed air has long been described as the fourth utility after electricity, natural
More informationEIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S
EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 500 Btu MODEL # S AAC-142-4XT AAC-142-4XT-HC AAC-142-4XT-XXXXX Cooling Solutions for Mission-Critical Electronics
More informationThe Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description
24-500 by The Leading Enterprise Internet of Things Solution VOLTAGE DETECT Wireless AC Voltage Detection Sensors (24-500 VAC) General Description The ALTA wireless AC voltage detection sensor can interface
More informationEIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP
EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP Cooling Solutions for Mission- Critical Electronics This manual
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L
GUARDIAN SERIES K2NA6C14DP50L Keep This Manual With Air Conditioner AIR CONDITIONER OPERATOR'S MANUAL CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER, IT IS IMPORTANT THAT THIS MANUAL BE READ
More informationEnvironmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.
As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers need for high quality products. We adopt the latest designs and technology to make sure that our products
More informationV-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N
V-SERIES Air Conditioner VA08 Model INSTRUCTION MANUAL Rev. F P/N 90164959 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationSPECTRACOOL Indoor & Outdoor Air Conditioners
PH FX ( Product Overview : SPECTRACOOL Indoor & Outdoor Air Conditioners G52 Indoor Model G57 Outdoor Model G28 Indoor Model 18 18 Product Overview : Makes electronics cooling easier, so you can go about
More informationAIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner
RACK-MOUNTED KA4C3.5H9R with Serial Numbers up to and including G17A2183 K2A4C3.5H9R with Serial Numbers up to and including D17A1221 KA4C3.5H10R with Serial Numbers up to and including L14A3003 K2A4C3.5H10R
More informationSECTION AIR COILS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 82 16 AIR COILS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in the section
More informationG /6000 BTU/Hr. 1172/1758 Watt
Spec-728 E Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Indoor/Outdoor G57 2 BTU/Hr. 5861 Watt G52 8/12 BTU/Hr. 23/35 Watt G28 4/6 BTU/Hr. 1172/ Watt Clean AirFlow Ambient
More informationComfort. Description. Applications
Blower Heater 3-35 kw 10,00-119,40 Btuh 40 to 90 Volts, 50/0 Hz 31 Stainless Steel Case Shown 3 Phase ATEX, GOST, CE IIG Exd IIB T3 Description Type is designed to heat areas classified as hazardous locations
More informationThe Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors
by The Leading Enterprise Internet of Things Solution THERMOCOUPLE Wireless Thermocouple Sensors General Description The ALTA Wireless Thermocouple Sensor is available with a hardwired thermocouple or
More informationPACKAGED TERMINAL AIR CONDITIONER SOLUTIONS
PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS Modern features and controls Superior sound performance Smaller footprint Semi-custom options PROFILE Evergreen Products is your complete solution for Packaged
More information