Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Size: px
Start display at page:

Download "Enclosure Heaters. Zone 1, Zone 2 & Safe Area"

Transcription

1 Enclosure Heaters Zone 1, Zone 2 & Safe Area

2 CONTACT INFORMATION OFFSHORE SOLUTIONS Subject to change without prior notice TPS2121 REV. D Kjetil Tengesdal Sales Director Offshore Solutions Special fields: High Voltage, ExP and ExD T E kjetil.tengesdal@stahl-tranberg.com Reidar Abrahamsen Key Account Manager Offshore Solutions Special fields: Heat Tracing, Cable Glands T E reidar.abrahamsen@stahl-tranberg.com Roy Mork Sales Engineer Offshore Solutions Special fields: Ex Heater, Tube Trace T E roy.mork@tranberg.com Synnøve R. Wiull Sales Support Offshore Solutions Special fields: Wholesales T E synnove.wiull@tranberg.com Tor Morten Berge Sales Support Offshore Solutions Special fields: Junction Boxes Exe, Stainless Steel Cabinets T E tor.berge@tranberg.com Marco Demmer Sales Engineer Offshore Solutions Special fields: 3D Designs T E marco.demmer@stahl-tranberg.com Per Helgeland Marketing Manager T E per.helgeland@stahl-tranberg.com

3 Tranberg Enclosure Heaters Zone 1, Zone 2 & Safe Area Introduction Tranberg quality heater for the professional oil & gas industry. High volumes of heaters delivered to projects worldwide. Compact design - easy to install - high effect output - low maintenance. Stainless steel and acid proof, AISI 316L. 50W W. Self-limiting or thermostat, external thermostat also possible. Stable effect curve. Very good heat distribution. Purpose To be installed inside junction boxes, cabinets, panels, enclosures, skids, weather protection housings, containers, fi-fi equipment, fire hose cabinets, cabinets for life jackets and survival suits, control rooms, etc. For the purpose of: Prevent moisture/ anti-condensation. Climatic control. Frost protection. Heat up / maintain desired temperature. Heat loss calculation Tranberg can make a heat loss calculation. To calculate the heat loss there are important factors to be considered: Volume and size of enclosure. Insulation (eg. Armaflex) or not? Wind (-speed). Indoor or outdoors. Minimum ambient temperature. Heat up/ temperature maintenance. Frost protection. Series TEF 9202 series, T4, 120V/240V, 50/60 Hz. 50W - 100W. For use in enclosures IP54 or better. TEF 9207 series, T3, 240V, 50/60 Hz. 100W W. IP66. TEF 9208 series, T4, 240V, 50/60 Hz. 50W - 600W. For use in enclosures IP54 or better. TEF 9209 series, T4, 120V, 50/60 Hz. 50W - 600W. For use in enclosures IP54 or better.

4 Approvals ATEX (Europe) IEC Ex (worldwide) CSA (USA + Canada) EAC (Russia) Versions Composite heater -self-limiting (fig. 1). With flying lead (1 or 1,5 m cold cable) - self-limiting (fig. 2). With junction box - self-limiting (fig. 3). With junction box + integrated ambient air thermostat +5 C or +15 C (fig. 4). Fig. 4 Fig. 3 Fig. 2 Fig. 1

5 Tranberg Enclosure Heaters Zone 1, Zone 2 & Safe Area Installation Easy to install - see datasheet / user manual. To be installed in lower half of enclosure - recommended. Vertical / horizontal / flat. Possible positions in enclosure Installed in side wall Installed in door Installed in bottom Installed on mounting plate

6 A short guide for selection of heater type Heater Type TEF 9202 TEF 9207 TEF 9208 TEF 9209 Input power 120/240 VAC 240 VAC 240 VAC 120 VAC Hertz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Max. circuit breaker 16A 16A 16A 16A Temp. Class T4 T3 T4 T4 For outdoor use (IP66) No IP66 No No For use in enclosure Anti condensation Frost protection Heating For certified enclosure with IP54 or more Any enclosure For certified enclosure with IP54 or more For certified enclosure with IP54 or more Approvals: IECEx ATEX CSA EAC On request On request Available versions: Flying lead 1,5 meter Junction box Junction box and integrated thermostat Available effect W W W W Heater Applications TEF 9202 TEF 9207 TEF 9208 TEF 9209 Junction boxes Cabinets Panels Skids Fire hose cabinets Cabinets for survival suits and life jackets Containers Control rooms Weater protection houses 120VAC for US and Canada 240VAC for Russia Installed in fire hose cabinet Installed in junction box Installed in cabinet

7 ENCLOSURE HEATER TEF 9207 Ex e T3 240 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS3007 REV. P Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing. With flying lead electrical connection. Delivered with power output from 100W to 500W at 0 C. TECHNICAL DATA APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. ESTIMATED POWER OUTPUT OF HEATER IN RESPECT TO AMBIENT TEMPERATURE Ex-protection ATEX & IECEx: Ex-protection CSA: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: II 2 G Ex e IIC T3 Gb AEx e II / Ex e II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60 Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Electrical connection: Connect to max. 16A circuit breaker. Earth leakage protection device or insulation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. Flying lead, 2 x 2.5mm2 + PE IP protection: IP66 According to EN Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract:

8 TEF 9207 ENCLOSURE HEATER DESCRIPTION EL No. Part No. Enclosure heater, 0 C Enclosure heater, 0 C Enclosure heater, 0 C Enclosure heater, 0 C DIMENSIONS *Nominal output Overall dimensions Mounting dimension Weight Length flying lead A B C D E 100W ,62 kg. 1 meter 200W ,44 kg. 1,5 meter 300W ,42 kg. 1,5 meter 500W ,02 kg. 1,5 meter *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 4xØ6 mounting holes on the rear side of the heater. Hold the heater close to the installation surface, and insert the M6 screws in each of the 4 mounting holes. Use a tool to tighten the screws firmly to secure the heater.

9 ENCLOSURE HEATER TEF 9207 Ex e T3 240 VAC, WITH JUNCTION BOX ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS3008 REV. Q Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with power output from 100W to 600W at 0 C. TECHNICAL DATA Sandwich model Ex-protection ATEX and IECEx: Ex-protection CSA: Optional ambient temp. : II 2 G Ex e IIC T3 Gb AEx e II / Ex e II -50 C to +50 C APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. ESTIMATED POWER OUTPUT OF HEATER IN RESPECT TO AMBIENT TEMPERATURE Max. withstand ambient temp.: Nominal voltage: +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. 6mm 2 : pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs IP protection: IP66 According to EN Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract:

10 TEF 9207 ENCLOSURE HEATER W/JUNCTION BOX DESCRIPTION El No. Part No. Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C (Sandwich) Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C (Sandwich) Enclosure heater with junction box, 0 C (Sandwich) DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W ,92 kg. 200W ,74 kg. 300W ,72 kg. 400W ,44 kg. 500W ,32 kg. 600W ,76 kg. 1000W ,50 kg. *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A xØ6 mounting holes on the rear side of the heater. Use a tool to tighten the screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. For the sandwich model, insert the M6 screws and a washer in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

11 ENCLOSURE HEATER TEF 9207 Ex e, T3 240 VAC, WITH JUNCTION BOX AND THERMOSTAT ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS3009 REV. S Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with ambient air thermostat, +5 C or +15 C and power output from 100W to 600W at 0 C ambient, still air. TECHNICAL DATA Sandwich model Ex-protection ATEX & IECEx: Ex-protection CSA: Operational ambient temp.: Max. withstand ambient temp.: II 2 G Ex e mb IIC T3 Gb AEx e mb II / Ex e mb II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Ambient air thermostat, integrated in heater junction box. Low maintenance. ESTIMATED POWER OUTPUT OF HEATER IN RESPECT TO AMBIENT TEMPERATURE Nominal voltage: 240V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. 6mm 2 : pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) Thermostat: 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs 1 pc. ambient air sensing thermostat Switching temp.: +5 C or +15 C Hysteresis: +5 C / -5 C IP protection: IP66 According to EN Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract:

12 TEF 9207 ENCLOSURE HEATER W/ JUNCTION BOX AND THERMOSTAT DESCRIPTION DIMENSIONS EL No. *Part No. +5 C(+5/-5 C) EL No. *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F *Part No. +15 C(+5/-5 C) Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C (Sandwich) Enclosure heater with junction box and thermostat, 0 C (Sandwich) Enclosure heater with junction box and thermostat, 0 C (Sandwich) *Note: Ambient Air Thermostat : +5 C : Switches heater ON at approx. +3 C ambient temperature, and OFF at approx. 11 C ambient temperature Ambient Air Thermostat : +15 C : Switches heater ON at approx. +10 C ambient temperature, and OFF at approx. 20 C ambient temperature 100W ,92 kg. 200W ,74 kg. 300W ,72 kg. 400W ,44 kg. 500W ,32 kg. 600W ,76 kg. 1000W ,50 kg. *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A * INTERNAL CABLES FROM HEATER PLATE (INSTALLED AT TRANBERG FACTORY) Standard model: 4xØ6 mounting holes on the rear side of the heater. Standard model: Use a tool to tighten the 4xM6 screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. Sandwich model: Insert 4xM6 screws and washers in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

13 ENCLOSURE HEATER TEF 9208 Ex e T4 240 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5003 REV. E Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing. With flying lead electrical connection. Delivered with power output from 50W to 300W at 0 C. TECHNICAL DATA APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Ex-protection ATEX & IECEx: Ex-protection CSA: Ex-protection EAC: Operational ambient temp.: Max. withstand ambient temp.: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e II / Ex e II 1Ex e IIC T4 Gb X or 1Ex e mb IIC T4 Gb X -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. Nominal voltage: 240V 50/60 Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X Electrical connection: IP protection: Flying lead, 2 x 2.5mm2 + PE For use in enclosures with IP54 or higher. ATEX certificate No.: Nemko 11ATEX1098X Output accuracy: Approx. ±10% CSA Certificate: CSA Master contract: EAC certificate: No TC: RU C-NO.MШ06.B Серия RU No

14 TEF 9208 ENCLOSURE HEATER DESCRIPTION Part No. Enclosure heater, 0 C Enclosure heater, 0 C Enclosure heater, 0 C Enclosure heater, 0 C DIMENSIONS *Nominal output Overall dimensions Mounting dimension Weight Length flying lead A B C D E 50W kg. 1 meter 100W kg. 1 meter 175W kg. 1,5 meter 300W kg. 1,5 meter *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 4xØ6 mounting holes on the rear side of the heater. Hold the heater close to the installation surface, and insert the M6 screws in each of the 4 mounting holes. Use a tool to tighten the screws firmly to secure the heater.

15 ENCLOSURE HEATER TEF 9208 Ex e T4, 240 VAC, WITH JUNCTION BOX ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5004 REV. E Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with power output from 100W to 600W at 0 C. Sandwich model TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Ex-protection EAC: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e II / Ex e II 1Ex e IIC T4 Gb X or 1Ex e mb IIC T4 Gb X APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract: EAC certificate: No TC: RU C-NO.MШ06.B Серия RU No Optional ambient temp. : Max. withstand ambient temp.: Nominal voltage: -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. 4mm 2 : pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) IP protection: 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs Output accuracy: Approx. ±10% For use in enclosures with IP54 or higher.

16 TEF 9208 ENCLOSURE HEATER W/JUNCTION BOX DESCRIPTION Part No. Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C (Sandwich) DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W ,92 kg. 175W ,74 kg. 300W ,72 kg. 600W ,76 kg. *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A xØ6 mounting holes on the rear side of the heater. Use a tool to tighten the screws firmly to secure the heater. For the sandwich model, insert the M6 screws and a washer in the mounting brackets as shown. Use a wrench for tightening the screws firmly. Note! Never install the heater with junction box facing upwards.

17 ENCLOSURE HEATER TEF 9208 Ex e, T4 240 VAC, WITH JUNCTION BOX AND THERMOSTAT ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5005 REV. G Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with ambient air thermostat, +5 C or +15 C and power output from 100W to 600W at 0 C ambient, still air. Sandwich model APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Ex-protection EAC: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e II / Ex e II 1Ex e IIC T4 Gb X or 1Ex e mb IIC T4 Gb X -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 240V 50/60Hz FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Ambient air thermostat, integrated in heater junction box. Low maintenance. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract: EAC certificate: No TC: RU C-NO.MШ06.B Серия RU No Material: AISI 316L / EN Electrical protection: Terminals in junction box: Cable glands: Thermostat: IP protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. 4mm 2 : pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs 1 pc. TEF E204/622 M25/D2/9mm (Ø11,0-15,0mm),1 pc. TEF 7302 M25 breather/drain plug & TEF 650 M20/M25 stopping plugs Output accuracy: Approx. ±10% 1 pc. ambient air sensing thermostat. Switching temp.: +5 C or +15 C. Hysteresis: +5 C / -5 C For use in enclosures with IP54 or higher.

18 TEF 9208 ENCLOSURE HEATER W/ JUNCTION BOX AND THERMOSTAT DESCRIPTION *Part No. +5 C(+5/-5 C) *Part No. +15 C(+5/-5 C) Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C (Sandwich) *Note: Ambient Air Thermostat : +5 C : Switches heater ON at approx. +3 C ambient temperature, and OFF at approx. 11 C ambient temperature Ambient Air Thermostat : +15 C : Switches heater ON at approx. +10 C ambient temperature, and OFF at approx. 20 C ambient temperature DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W ,92 kg. 175W ,74 kg. 300W ,72 kg. 600W ,76 kg. *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A * INTERNAL CABLES FROM HEATER PLATE (INSTALLED AT TRANBERG FACTORY) Standard model: 4xØ6 mounting holes on the rear side of the heater. Standard model: Use a tool to tighten the 4xM6 screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. Sandwich model: Insert 4xM6 screws and washers in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

19 ENCLOSURE HEATER TEF 9209 Ex e T4 120 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5065 REV. D Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing. With flying lead electrical connection. Delivered with power output from 50W to 300W at 0 C. TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e mb II / Ex e mb II APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 120V 50/60 Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. Electrical protection: Electrical connection: IP protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. Flying lead, 2 x 2.5mm2 + PE For use in enclosures with IP54 or higher. Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract:

20 TEF 9209 ENCLOSURE HEATER DESCRIPTION Part No. Enclosure heater, 0 C Enclosure heater, 0 C Enclosure heater, 0 C Enclosure heater, 0 C DIMENSIONS *Nominal output Overall dimensions Mounting dimension Weight Length flying lead A B C D E 50W kg. 1 meter 100W kg. 1 meter 175W kg. 1,5 meter 300W kg. 1,5 meter *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 4xØ6 mounting holes on the rear side of the heater. Hold the heater close to the installation surface, and insert the M6 screws in each of the 4 mounting holes. Use a tool to tighten the screws firmly to secure the heater.

21 ENCLOSURE HEATER TEF 9209 Ex e T4, 120 VAC, WITH JUNCTION BOX ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5066 REV. D Standard model Sandwich model APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Low maintenance. Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with power output from 100W to 600W at 0 C. TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Optional ambient temp. : Max. withstand ambient temp.: Nominal voltage: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e mb II / Ex e mb II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 120V 50/60Hz Inrush current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Terminals in junction box: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. 4mm 2 : pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs Cable glands: 1 pc. TEF E204/622 M25/ D2/9mm (Ø11,0-15,0mm) IP protection: 1 pc. TEF 7302 M25 breather/ drain plug TEF 650 M20/M25 stopping plugs Output accuracy: Approx. ±10% For use in enclosures with IP54 or higher. APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract:

22 TEF 9209 ENCLOSURE HEATER W/JUNCTION BOX DESCRIPTION Part No. Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C Enclosure heater with junction box, 0 C (Sandwich) DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W ,92 kg. 175W ,74 kg. 300W ,72 kg. 600W ,76 kg. *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A xØ6 mounting holes on the rear side of the heater. Use a tool to tighten the screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. For the sandwich model, insert the M6 screws and a washer in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

23 ENCLOSURE HEATER TEF 9209 Ex e, T4 120 VAC, WITH JUNCTION BOX AND THERMOSTAT ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5067 REV. D Standard model Globally approved Ex e, self regulating enclosure heater. AISI 316L acid resistant steel housing and junction box. Junction box for electrical connections. Delivered with ambient air thermostat, +5 C or +15 C*(see page 2) and power output from 100W to 600W at 0 C ambient, still air. Sandwich model TECHNICAL DATA Ex-protection ATEX & IECEx: Ex-protection CSA: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: Ta= -50 C..+50 C II 2 G Ex e IIC T4 Gb Ex e mb IIC T4 Gb AEx e mb II / Ex e mb II -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is deenergized) 120V 50/60Hz APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Inrush Current: 4 x Nominal current for min. 30 sec. Material: AISI 316L / EN Electrical protection: Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. FEATURES AND BENEFITS Low profile, easy to fit inside cabinets. Self regulating heating element. Prevents overheating. Rugged AISI 316L, acid steel construction. Ambient air thermostat, integrated in heater junction box. Low maintenance. Terminals in junction box: Cable glands: Thermostat: IP protection: 6mm 2 : pcs 2,5mm 2 : 2 pcs 10mm 2 PE terminals: 3 pcs 1 pc. TEF E204/622 M25/D2/9mm (Ø11,0-15,0mm),1 pc. TEF 7302 M25 breather/drain plug & TEF 650 M20/M25 stopping plugs 1 pc. ambient air sensing thermostat. Switching temp.: +5 C or +15 C. Hysteresis: +5 C / -5 C For use in enclosures with IP54 or higher. Output accuracy: Approx. ±10% APPROVALS AND CERTIFICATES IECEx certificate No.: IECEx NEM X ATEX certificate No.: Nemko 11ATEX1098X CSA Certificate: CSA Master contract:

24 TEF 9209 ENCLOSURE HEATER W/ JUNCTION BOX AND THERMOSTAT DESCRIPTION *Part No. +5 C(+5/-5 C) *Part No. +15 C(+5/-5 C) Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C Enclosure heater with junction box and thermostat, 0 C (Sandwich) *Note: Ambient Air Thermostat : +5 C : Switches heater ON at approx. +3 C ambient temperature, and OFF at approx. 11 C ambient temperature Ambient Air Thermostat : +15 C : Switches heater ON at approx. +10 C ambient temperature, and OFF at approx. 20 C ambient temperature DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E F 100W ,92 kg. 175W ,74 kg. 300W ,72 kg. 600W ,76 kg. *Note: Nominal at still C MOUNTING INSTRUCTIONS 4xM6 mounting holes 920A * INTERNAL CABLES FROM HEATER PLATE (INSTALLED AT TRANBERG FACTORY) Standard model: 4xØ6 mounting holes on the rear side of the heater. Standard model: Use a tool to tighten the 4xM6 screws firmly to secure the heater. Note! Never install the heater with junction box facing upwards. Sandwich model: Insert 4xM6 screws and washers in the mounting brackets as shown. Use a wrench for tightening the screws firmly.

25 ENCLOSURE HEATER TEF 9202 COMPOSITE Ex e T4 120/240 VAC, WITH FLYING LEAD ZONE 1, ZONE 2 & SAFE AREA Subject to change without prior notice TPS5559 REV. C Globally approved Ex e, self regulating enclosure heater. Made of light weight composite material. TECHNICAL DATA Composite APPLICATION For use inside equipment enclosures and cabinets to prevent condensation and provide climatic control. Frost protection. Temperature maintenance. Anti-condensation. FEATURES AND BENEFITS Ex-protection ATEX & IECEx: Operational ambient temp.: Max. withstand ambient temp.: Nominal voltage: Material: Electrical protection: IP protection: Flying lead: II 2 G Ex e IIC T4 Gb -50 C to +50 C +50 C (Heater is energized) +80 C (Heater is de-energized) 120V/240V 50/60Hz Composite material Connect to max. 16A circuit breaker. Earth leakage protection device or isolation device, depend on type of system of earth according to IEC 364-3, chapter 31, and EN Annex D. For use in enclosures with IP54 or higher. 1,5m, 2x2,5mm 2 + PE Light weight composite structure. Compact. Easy to install. Can be supplied with DIN rail module. Self regulating heating element. Prevents overheating. Low maintenance. Corrosion proof. Fire resistant retardant UL 94, Classification V-0. Low inrush current. APPROVALS AND CERTIFICATES IECEx PRE X Presafe 17ATEX9667X

26 TEF 9202 ENCLOSURE HEATER W/ FLYING LEAD DESCRIPTION Part No. Enclosure Heater Ex 240V-50W T4 Composite with flying 0 C Enclosure Heater Ex 240V-100W T4 Composite with flying 0 C Enclosure Heater Ex 120V-50W T4 Composite with flying 0 C Enclosure Heater Ex 120V-100W T4 Composite with flying 0 C Optional DIN rail bracket DIMENSIONS *Nominal output Overall dimensions Mounting dimensions Weight A B C D E 50W ,56 kg. 100W ,76 kg. *Note: Nominal at still 0 C 000A Optional DIN rail module, can be placed in both horizontal and vertical position.

27 TRANBERG AS COMPANY DETAILS Subject to change without prior notice TPS2082 REV. B Products designed and manufactured in close cooperation with demanding customers have enabled Tranberg to supply the oil and gas industry with high quality electro mechanical products with low life time cost and high functionality. OFFSHORE SOLUTIONS When reliability matters. No matter it it`s within arctic or tropical conditions. Tranberg Offshore Solutions are performing under harsh and hazardous environment. Furthermore Tranberg is the exclusive distributor for Thermon - the world s leading manufacturer of heating cables - in Norway. Primarily active within the offshore and petrochemical industry. We can supply complete solutions from individual components to complete heat tracing systems for the following applications: Winterization of pipe systems, instruments, tanks and vessels Temperature maintenance of pipes, tanks and vessels Anti-icing/de-icing of helideck, safety and emergency areas Electrical process heating Products are developed and testet together with offshore vessel ship owners for world wide operations in both arctic and tropic environments. If the product are good enough for them, they are good enough for you. MARINE SOLUTIONS When durability matters. Tranberg Marine Solutions are the No. 1 Supplier for Offshore Vessels Tranberg supplies products within the following areas for ships: Marine Lighting Helideck Lighting Audible and Visual Signals Electrical De-Ice/ Anti-Ice Installation Equipment Helideck equipment manufactured by Tranberg is delivered to offshore installations, oil tankers, ships, hotels and hospitals all over the world. Helideck equipment from Tranberg is used for operation on elevated and non-elevated helidecks. HELIDECK SOLUTIONS When safety matters. Tranberg Helideck Solutions is the market leader for operation on elevated and non-elevated helidecks. All helideck lighting products from Tranberg: Compact and rugged construction Integrated terminal box LED lights with very long operating life ( up to hours ) All products complies with : ICAO latest standards Resistance to vibration Quick opening for installation Products certified for use in Zone 1, Zone 2 and Safe Area, IECEx

28 TGP5708 REV. B (PUBLIKASJON 620 AXAPTA) References Edvard Grieg Aasta Hansteen Ivar Aasen Mariner Gina Krogh projects Johan Sverdrup project Goliat project.. Martin Linge Johan Castberg Yamal project: (!) heaters R.Stahl Tranberg AS Main office Strandsvingen 6 N-4032 Stavanger, Norway T (47) F (47) Oslo office Luhrtoppen 2 N-1470 Lørenskog, Norway T (47)

TRANBERG HIGH VOLTAGE SOLUTIONS

TRANBERG HIGH VOLTAGE SOLUTIONS TRANBERG HIGH VOLTAGE SOLUTIONS TRANBERG.COM 1 TRANBERG was established in 1901 and is located in Stavanger, the oil capital on the west coast of Norway. Due to the oil industry, oil companies and offshore

More information

TRANBERG HIGH VOLTAGE SOLUTIONS

TRANBERG HIGH VOLTAGE SOLUTIONS TRANBERG HIGH VOLTAGE SOLUTIONS TRANBERG.COM 1 TRANBERG was established in 1901 and is located in Stavanger, the oil capital on the west coast of Norway. Due to the oil industry, oil companies and offshore

More information

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL Subject to change without prior notice TUM7 REV. B.08.08 SAFETY INSTRUCTIONS The TEF 9980 status light may be installed in Zone, or safe area. The Equipment shall not be installed in Zone 0! HANDLE WITH

More information

TRANBERG HIGH VOLTAGE SOLUTIONS

TRANBERG HIGH VOLTAGE SOLUTIONS TRANBERG HIGH VOLTAGE SOLUTIONS TRANBERG.COM 1 TRANBERG was established in 1901 and is located in Stavanger, the oil capital on the west coast of Norway. Due to the oil industry, oil companies and offshore

More information

Fan Heaters Type VLEx

Fan Heaters Type VLEx Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

GENERAL SPECIFICATION ELECTRICAL

GENERAL SPECIFICATION ELECTRICAL GENERAL SPECIFICATION ELECTRICAL GS ELE 331 Tape trace heating 00 10/04 First issue Rev. Date Notes Contents 1. Scope...3 2. Reference documents...3 3. Environmental Conditions...4 4. Technical Requirements...5

More information

Temperature Control and Monitoring. innovations in heat tracing

Temperature Control and Monitoring. innovations in heat tracing Temperature Control and Monitoring innovations in heat tracing Table of Contents Overview 4-5 Type Ex-Box REG/DIS Type Ex-Box REG/LED Temperature Controller for Hazardous Areas Temperature Controller for

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Fan Heaters Type TXI, WBK, WBG, Delta & VLE Fan Heaters Type TXI, WBK, WBG, Delta & VLE Sinus Jevi has an extensive program of high quality fan heaters for every application. From cost effective model TXI to high power stationary model VLE, all

More information

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System Low Profile - Less than 25 mm Precision Machined Interlock Mounting System Special Anti-Slip Coating Upgrading Helicopter deck signalisation lighting

More information

Sinus Jevi (Explosion-Proof) Condens Heaters

Sinus Jevi (Explosion-Proof) Condens Heaters Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

The next generation thermometer from the global leader

The next generation thermometer from the global leader akm oti/wti Remote mount thermometers The next generation thermometer from the global leader Accomplish the most demanding control and alarm configurations Reduce failure costs with reliable AKM bellows

More information

DB4 Range - SPEAKERS - Up to 25 Watts

DB4 Range - SPEAKERS - Up to 25 Watts DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Lamp Supply (Recommended)

Lamp Supply (Recommended) SGX Europe Sp. z o.o. IR600 Datasheet Infrared Gas Sensor for Hazardous Areas (Fixed Systems) The IR600 Series gas sensors are designed to detect and monitor the presence of CO 2, hydrocarbons and acetylene

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS PENTAIR CLEAN AIR SYSTEMS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET Installation and Operating Instructions. Oil Separator Alarm Device Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec

More information

ExPolar Heating System

ExPolar Heating System ExPolar Heating System for use with Max actuators and Cos / Bin / Reg sensors in extreme temperatures to 50 C ATEX certified in acc. with directive 201 / / EU for use in zones 1, 2, 21 and 22 ExPolar -...

More information

SET Installation and Operating Instructions. Level switch for one sensor

SET Installation and Operating Instructions. Level switch for one sensor Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel.: +358 29 006 260 Fax: +358 29 006 1260 7.11.2013 Internet: www.labkotec.fi 1/14 SET-1000 Level switch for one sensor Copyright 2013 Labkotec Oy

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Explosion-proof Immersion Heater Type D-8660

Explosion-proof Immersion Heater Type D-8660 Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to

More information

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT EXPLOSION PROTECTION Experts in Equipment for Explosive Atmospheres Ex SPECIALISTS TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT LIGHTING Portable, Temporary & Fittings Hazardous area lighting and

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION SGX Europe Sp. z o.o. VQ600 Datasheet Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) The VQ600 Series is designed to detect and monitor various gases in the range 0 to 100% LEL for combustible

More information

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing Electrical Heat Tracing in Hazardous Areas innovations in heat tracing Table of Contents Introduction 3 1. Heating Cables Type ELSR-N Self-regulating Heating Cable up to 80 C 4-5 Type ELSR-LS Self-regulating

More information

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation The Series convection heater, with ratings up to 5000 watts, is designed for heating spaces where explosive substances are or may be present. The is available with either C CSA US or CE/ ATEX approvals.

More information

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such

More information

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE 763.576.3200 SPEC-00051 O763.422.2211 THERMAL MANAGEMENT ACCESSORIES ENCLOSURE HEATERS Accessories Enclosure Heaters TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP

More information

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55 www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL PRODUCT NAME: SD-100-1- WEATHER-PROOF SOUNDER/HORN DOC NO.: EX-TECH SIGNALLING SAS-12-SD100-1-TM REV03 WEATHERPROOF SOUNDER/HORN IP66 SD-100 SERIES EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN

More information

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS 3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where,

More information

Documentation. Parallel Heating Cable. Type: ELP

Documentation. Parallel Heating Cable. Type: ELP Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant

More information

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations AEU1 Explosion-Proof Electric Air Heater For Hazardous Locations 0518 II 2G, Ex d IIB T4 Gb IP55 (ATEX) Ex d IIB T4 Gb IP55 (IECEx) 1ExdIIBT4 X IP55 (EAC Ex) (Suitable for ATEX/IECEx/EAC Ex Zone 1 & 2)

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

A2S s Company Profile

A2S s Company Profile A2S s Company Profile Avertisseurs sonore et visuel Détecteur Communication Eclairage Equipement d installation Contrôle commande World Class Developer of Electrical Equipement for use in Hazardous Areas

More information

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED Hazardous Area LED Lighting Hazard Gard LED Luminaires Hazard Gard EVLL LED Hazard Gard EVLL LED Safe. Reliable. Efficient. Featuring the industry's broadest range of LED luminaires for harsh and hazardous

More information

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate GETTING STARTED GUIDE NI 9213 16 TC, ±78 mv, 24 Bit, 75 S/s Aggregate This document explains how to connect to the NI 9213. Note Before you begin, complete the software and hardware installation procedures

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement

More information

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger X-am 3000 ST-2881-2003 Dräger X-am 3000 is an innovative 2 to 4 gas warning-device. This small and lightweight instrument

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with

More information

PANELBOARD PROTECTION ON A GLOBAL SCALE

PANELBOARD PROTECTION ON A GLOBAL SCALE PANELBOARD PROTECTION ON A GLOBAL SCALE INTRODUCTION WHY? No matter what environment, location or power requirement, Appleton panelboards have you and your facility covered. From a petrochemical plant

More information

the next generation thermometer from the global leader

the next generation thermometer from the global leader OTIWTI Remote mount thermometers (AKM) the next generation thermometer from the global leader Six switch capability, sequentially independent, with adjustable hysteresis Reduce failure costs with reliable

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Thermal Management Products & Accessories for Enclosures

Thermal Management Products & Accessories for Enclosures Thermal Management Products & Accessories for Enclosures Photo: STEGO International Headquarters in Germany STEGO, Inc. 1395 S. Marietta Parkway Building 800 Marietta, GA 30067 Tel: (770) 984-0858 Fax:

More information

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL 25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low

More information

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL Hazardous Location Heaters Thermostat INSTRUCTION MANUAL Rev. K 2018 nvent P/N 89115890 TABLE OF CONTENTS Warranty and Return Policy...2 Application...3 Control Accuracy...3 Technical Data...3 Design Data...3

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements ExTR Reference Number...: ExTR Free Reference Number...: 223531 Compiled by + signature (ExTL)...: Reviewed by + signature (ExTL)...: NO/NEM/ExTR12.0018/00 Stig André Norheim Arne Hortman Date of issue...:

More information

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable 120W Hazardous Location LED Fixture - 12-24V DC - Modbus TCP/IP - Network Controlled - Dimmable Part #: HAL-ANC-60-120W-ITG-LED-DIMM-1224 Page: 1 The Larson Electronics HAL-ANC-60-120W-ITG-LED-DIMM-1224

More information

Enclosure Heaters and Fan Heaters

Enclosure Heaters and Fan Heaters Enclosure Heaters and Fan Heaters ISC carries innovative products for heating, cooling, temperature and humidity control of electronic enclosures. Our products are renowned for their reliability, long

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous

More information

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. All icon products are Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. Certified to global standards: ATEX, IECEx, TIIS, EAC-EX, ETL approved

More information

Explosion Proof Manual Call Points Series MCP

Explosion Proof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing

More information

ELECTRICAL HEATING SYSTEMS ENCLOSURES and JUNCTION BOXES CABLE GLANDS HELIDECK LIGHTING SYSTEM REFERENCES. Helideck

ELECTRICAL HEATING SYSTEMS ENCLOSURES and JUNCTION BOXES CABLE GLANDS HELIDECK LIGHTING SYSTEM REFERENCES. Helideck artdirector.no Edition 10/2015 REFERENCES Heat Tracing, Junction Boxes, Enclosure Systems & Cable Glands Aibel Aker Solutions Apply Rosenberg WorleyParsons BP ConocoPhillips Shell Statoil Det Norske De-Ice

More information

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments. HDL106 LED LUMINAIRES For Harsh & Hazardous Environments www.chalmit.com Quality, Reliability and Low Maintenance Our LED Product Range Chalmit has over a century s worth of experience in providing cutting

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Approved by: Document no.: EGT

Approved by: Document no.: EGT ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken

More information

new new Industrial plugs and sockets

new new Industrial plugs and sockets Industrial plugs and sockets 213.1633 213.3236 221.1633 226.1636 New Optima series 16A-32A-63A-125A insulation voltage : 690V AC protection degree : IP44 and IP67 operating temperature : -25ºC to 40ºC

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

CR 027 PTC Fan Heater W

CR 027 PTC Fan Heater W CR 027 PTC Fan Heater 400-650 W Compact fan heater Heating power adjusts to ambient temperature Integrated adjustable thermostat Built-in overheat protection DI rail mountable The semiconductor CR 027

More information

Performance Data. curus Component Recognized; File No. E IP 20

Performance Data. curus Component Recognized; File No. E IP 20 TOUCH-SAFE HEATERS INDUSTRY STANDARDS curus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electrical, mechanical equipment from low temperatures, condensation, and corrosion with

More information

OilSET-1000 (12 VDC)

OilSET-1000 (12 VDC) Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009

More information

TX6831 Data Sheet. Features. Benefits

TX6831 Data Sheet. Features. Benefits Audio/Visual Alarm Combined audible and visual alarm signalling, for use with sensors and monitoring systems Environments: Mining Tunnelling Machine monitoring Features TX6831 For use with sensors and

More information

TraceNet ECM Series Control System

TraceNet ECM Series Control System TraceNet ECM Series Control System ECM Operating Guide Thermon Manufacturing Company TraceNet is a registered trademark of Thermon Manufacturing Company. ECM Operating Guide 2014, 2015 Thermon Manufacturing

More information

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1 emperature Multi-Input Device for Cabinet Installation Features Assembly For 8 temperature or analog sensors Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block GETTING STARTED GUIDE NI 9212 and TB-9212 8 TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block This document explains how to connect to the NI 9212 using the TB-9212. In this document,

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

Temperature Measurement Transmitters for field mounting

Temperature Measurement Transmitters for field mounting Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS Please read these instructions thoroughly before installation and ensure they are passed on to the end-user 1 1.0

More information

How Limit Switches Can Stop Machines from Going Boom

How Limit Switches Can Stop Machines from Going Boom How Limit Switches Can Stop Machines from Going Boom A Honeywell White Paper Safety is one of the top criteria when selecting a limit switch for hazardous location environments. In many cases, these switches

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev. STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate of Conformity: IECEx SIR 09.0111 http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/f076962... Page 1 of 3 22/01/2010 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

DB1 Range - HORNS - Up to 103 db(a)

DB1 Range - HORNS - Up to 103 db(a) DB1 Range - HORNS - Up to 103 db(a) Explosion-proof, Weatherproof Features UL listed Class I, Div. 1, Groups C & D. Class 1, Zone 1. ATEX approved. NEMA 4x, IP66. Certified temperature: 13 F to +158 F.

More information

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2 Compliances: ETL Listed Class I, Division 2, Groups A B C D, T6 at -40 deg C to +55 deg C ETL Listed Class I, Zone 2, Groups IIA, IIB+H2, IIC T6 at -40 deg C to +55 deg C ETL Listed to UL 844 & UL 1598

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information