Transcription

1 Technical manual 2G-TA 04 - Gas Combined Heat and Power Plants of 2G-Biogas, 2G-Natural gas and 2G-agenitor Series G-Box 50 2G-KWK-EG 2G-KWK-BGG 2G-agenitor G-BOX 50 2G-KWK-70EG 2G-KWK-100EG 2G-KWK-140EG 2G-KWK-200EG 2G-KWK-240EG 2G-KWK-250EG 2G-KWK-370EG 2G-KWK-400EG 2G-KWK-50BGG 2G-KWK-64BGG 2G-KWK-100BGG 2G-KWK-120BGG 2G-KWK-190BGG 2G-KWK-250BGG 2G-KWK-370BGG agenitor 206 agenitor 208 agenitor 212 agenitor 306 agenitor 312 agenitor 412 2G Energietechnik GmbH

2 2 of 8 2G Energietechnik GmbH

3 Contents 1 Purpose Safety information Effects of condensate in the propellant Preventing malfunctions caused by condensate in the propellant Minimum requirements with regard to gas quality General preconditions Changed limit values with the use of a catalytic converter G-TA 04 Gas (engl.) Edition: of 8

4 4 of 8 2G Energietechnik GmbH

5 1 Purpose This technical manual describes propellant properties required to operate a 2G Energietechnik combined heat and power plant. 2G Energietechnik products are to be fuelled only with gases which are not flammable in the state in which they exist outside of the motor (interface mixer connection). If necessary, additional plant specific measures must be taken in accordance with all applicable regulations (e.g. monitoring / regulation of oxygen concentrations in the gas emergency shut-down). For an intentional standstill of the plant (e.g. for repairs, maintenance and emergencies), a manual shut-off device outside the machine room must be provided, at best at the point where the gas line enters the machine room. The manual shut-off device is to be installed so that it cannot be operated by an unauthorised person. This applies especially so that the device cannot be moved to the open position from the locked position. It is the responsibility of the operating company to equip the fuel gas system with the required devices, to ensure that there are no leaks in the system and to ensure that all applicable regulations are fulfilled. 2 Safety information Malfunctions arising from a build-up of condensate in the available propellants are not covered under the guarantee. This is not the case if the scope of delivery contractually agreed with 2G Energietechnik expressly includes a gas dryer. Evaporated accompanying substances (which only occur in liquid form under certain circumstances) do not as a rule damage the motors. (This of course does not apply to gas components such as halogen and sulphur compounds, etc. which are known to cause damage.) As a matter of experience, malfunctions caused by inadequately dry gas usually occur outside of the actual motor in fittings, devices and piping. These malfunctions must be taken seriously. To ignore them can lead to serious motor malfunctions sooner or later. 2G-TA 04 Gas (engl.) Edition: of 8

6 3 Effects of condensate in the propellant Properties of the condensate: Acidic water and gas compressor cylinder oil form an emulsion Corrosion ( wear) TAN enrichment or ph reduction in the oil Carbon deposits on the: valves, piston ring grooves and slits 4 Preventing malfunctions caused by condensate in the propellant Preventing vapor formation by cooling and/or releasing. Mechanical separation (e.g. with the use of a cyclone or separator filter) and siphoning off of the condensate. The gas line to the motor is to be designed so that the gas does not cool further and is effectively not further decompressed by resistance or downstream pressure reducer. (If necessary, isolate the propellant line or equip it with an auxiliary heating element). Because, despite the absence of condensate build-up, a certain amount of condensate can still get into the motor, it is important that the condensate is largely free of acidifiers. To be certain, the ph value of the water extract collected by the condensate separators must be checked. The stronger the acid, the more damaging it can be, even with hardly detectable amounts of condensate, which can nevertheless get into the motor with the gas. 6 of 8 2G Energietechnik GmbH

7 Technical Manual 2G-TA 09 - Gas Changed limit values with the use of a catalytic converter 5 Minimum requirements with regard to gas quality Parameter Identifier Limit value Unit Notes: Methane number MN > 80 Low methane number after consultation with 2G Energietechnik Heating value H u,n > 5 kwh / Nm³ Chlorine content Cl < 80 mg / Nm³ CH4 Chlorine occurs as a volatile compound Fluoride content F < 40 mg / Nm³ CH4 Fluoride occurs as a volatile compound Overall Chlorine-fluoride Dust content < 5 µm (Cl, F) < 80 mg / Nm³ CH4 < 10 mg / Nm³ CH4 Oil vapour < 400 mg / Nm³ CH4 There may be no condensation in the intake tract Solvent in the combustion air VOC < 25 mg / Nm³ CH4 Consult with 2G Energietechnik if concentrations are higher Silicon content Si < 2 mg / Nm³ CH4 Consult with 2G Energietechnik if silicon concentrations are higher Total sulphur content Hydrogen sulphide content S < 200 mg / Nm³ Total sulphur includes hydrogen sulphide H 2 S < 150 / 228 ppm/ mg / Nm³ Ammonia content NH 3 < 40 / < 30 ppm/ mg / Nm³ CH4 Consult with 2G Energietechnik if concentrations are higher Relative humidity φ < 60 % There may be no condensation in the intake tract Temperature of the gas mix in accordance with gas / air mixer T G 10< T G < 30 C 2G-TA 04 Gas (engl.) Edition: of 8

8 5.1 General preconditions Parameter Limit value Unit Notes: Gas pressure, max. fluctuation speed 1 mbar / 2sec Hu fluctuation speed 1 % / 30 sec. 6 Changed limit values with the use of a catalytic converter The use of a catalytic converter intensifies the limit values as follows: (Data not listed in the table below remain unchanged) Parameter/ catalyst poison Identifier Limit value Unit Hydrogen sulphide content H 2 S < 5 ppm Sulphur content S < 5 mg / Nm³ Ammonia content NH³ < 40 / < 30 ppm/ mg / Nm³ Arsenic content As < 1 µg / Nm³ Mercury content Hg < 1 µg / Nm³ Lead content Pb < 2 µg / Nm³ Cadmium content Cd < 10 µg / Nm³ Zinc content Zn < 100 µg / Nm³ Phosphorous compounds and halogens < 5 mg / Nm³ Silicon content < 0 µg / Nm³ Silicon content Si < 0 µg / Nm³ Sodium content Na < 10 µg / Nm³ Calcium content Ca < 10 µg / Nm³ Bismuth content Bi < 1 µg / Nm³ Manganese content Mn < 10 µg / Nm³ Potassium content K < 10 µg / Nm³ Antimony content Sb < 1 µg / Nm³ Chlorine content Cl < 10 µg / Nm³ Iron content Fe < 10 µg / Nm³ Notes: 8 of 8 2G Energietechnik GmbH

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

Soil Test Report. HOME GARDEN VEGETABLE GARDEN Analysis Results

Soil Test Report. HOME GARDEN VEGETABLE GARDEN Analysis Results Analysis VEGETABLE GARDEN Analysis Results Result Account Number: 54321 Page: 1 of 6 Soil Test Rating Very Low Low Medium High Very High Organic Matter, % 4.6 Phosphorus, ppm P (Bray-1 Equiv.) 12 Potassium,

More information

Properly calibrating catalytic bead sensors: A practical guide

Properly calibrating catalytic bead sensors: A practical guide Properly calibrating catalytic bead sensors: A practical guide Catalytic explosives (CatEx) sensors offer precise and reliable detection of flammable gases provided they are optimally set for each detection

More information

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008 iso 9001:2008 Quality Management Systems Systéme de Qualité www.sgs.com possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor

More information

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Xgard. Fixed detectors For flammable, toxic or oxygen gases Fixed detectors For flammable, toxic or oxygen gases Xgard Xgard Type 1: Xgard Type 2: Xgard Type 3: Xgard Type 4: Xgard Type 5: Xgard Type 6: Xsafe: Intrinsically safe toxic and oxygen gas detector Flameproof

More information

Anorganic Fertilizer. Lenny Sri Nopriani, SP.MP

Anorganic Fertilizer. Lenny Sri Nopriani, SP.MP Anorganic Fertilizer Lenny Sri Nopriani, SP.MP Jargon Fertilizer Synthetic Fertilizers can be organic or inorganic Organic: from living material, contains C-C bonds; does not imply organic certification

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable

More information

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance 4P-90 CiTipeL Combustible Gas Sensor Part Number: PM143-000 Performance

More information

Refrigeration air dryer

Refrigeration air dryer Principle of refrigeration air dryer Pneumatic circuit (System diagram) Warm wet water is precooled by compressed air chilled and dehumidified by air balancer (A) (precooler). Precooled compressed air

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and

More information

Know Your Soil Getting the Dirt on Your Dirt FWAA. Dr. Steve Petrie Director of Agronomic Services

Know Your Soil Getting the Dirt on Your Dirt FWAA. Dr. Steve Petrie Director of Agronomic Services Know Your Soil Getting the Dirt on Your Dirt FWAA Dr. Steve Petrie Director of Agronomic Services Crop productivity Genetics Soil Temperature Environ ment Crop Yield Moisture Manage ment Take the time

More information

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada MultiGas Detection Ltd. Introduction & Capabilities Leduc Head Office Calgary Office MultiGas Detection

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man

More information

The plating industry

The plating industry The plating industry Environmental issues by electroplating Wastewater (from rinsing processes) Waste (liquid waste, sludge) Air pollution (extraction from hot and toxic process baths) Resource consumption

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

Complete Compressed Air System Audit Case Study - Southwestern Dairy Products Packaging Plant

Complete Compressed Air System Audit Case Study - Southwestern Dairy Products Packaging Plant Complete Compressed Air System Audit Case Study - Southwestern Dairy Products Packaging Plant To earn Professional Development Hours (PDH): 1. Log into the CONEXPO CON/AGG App 2. Go to this session in

More information

GEOL 408/508 INTRODUCTORY SOILS

GEOL 408/508 INTRODUCTORY SOILS GEOL 408/508 INTRODUCTORY SOILS Lecture = 3 hrs/week Lab = 3hrs/week Course = 4 credits Name/Define the Following 1. N 2 2. NH 3 3. NH + 4 4. NO - 2 5. NO - 3 6. protein 7. organics 8. organic matter 9.

More information

NM Water Resources Research Institute Environmental Conditions of the Animas and San Juan Watersheds with Emphasis on Gold King Mine

NM Water Resources Research Institute Environmental Conditions of the Animas and San Juan Watersheds with Emphasis on Gold King Mine The Gold King Mine Spill in the Context of Historical Water Quality Impacts to Utah s San Juan River and Lake Powell NM Water Resources Research Institute Environmental Conditions of the Animas and San

More information

SILOXA FAKA Gas Cleaning System

SILOXA FAKA Gas Cleaning System 1/6 Activated carbon adsorber for removing siloxanes and, if required, hydrogen sulphide (H 2 S) from sewage gas SILOXA s FAKA gas cleaning systems are highly efficient systems that are available in different

More information

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit Service instructions for contractors VIESMANN Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit VITOLADENS 300-T 1/2007 Please keep safe. Safety instructions Safety instructions

More information

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734) G450 Multi-gas Detector Field Operation Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com Warranty GfG Instrumentation warrants our products to be

More information

TEST REPORT Page 1 of 28. Uçar Oyuncak San.ve Tic.Ltd.Şti.

TEST REPORT Page 1 of 28. Uçar Oyuncak San.ve Tic.Ltd.Şti. TEST REPORT Page 1 of 28 REPORT NUMBER : TURT120014744-REVISED 04 APPLICANT NAME ADDRESS BUYER Uçar Oyuncak San.ve Tic.Ltd.Şti. Hadımköy Ömerli Mah.İstanbul Yolu Cad. No:195 Arnavutköy İstanbul TÜRKİYE

More information

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Catalytic Ex-Sensors DrägerSensors Dräger Catalytic Ex-Sensors DrägerSensors High product quality, low operational costs: Thanks to DrägerSensor CatEx PR technology, our sensors are resistant to poisoning and particularly stable over the

More information

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the

More information

Low mg/m

Low mg/m 1 (7) List 9.2.3 set Library name in Chempro100: CWA-9.2.3 Alarm indication Nerve Blister Library specified agents GA, GB, GD, GF VX HD L Low mg/m 3 0.1 0.1 2 2 Library unspecified agents/cases Nerve precursors

More information

Understanding the Balance

Understanding the Balance Understanding the Balance Soil is the foundation that builds strong crops, plants, roots and turf. Micro Biology in the soil is an absolute must in order to grow anything properly.. The Soil must contain

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Main Anthropogenic Sources of Greenhouse Gases Refrigerants Main Anthropogenic Sources of Greenhouse Gases Refrigerants Content Refrigerant definition Refrigerants Refrigerants as a source of GHG Refrigerant Definition A refrigerant is a substance or mixture, usually

More information

Crop Management Practices. By Simon Bedasie

Crop Management Practices. By Simon Bedasie Crop Management Practices Fertigation By Simon Bedasie Observations of a Visiting Consultant Water and fertilizer management looked like bucket chemistry. Very basic techniques for water and fertilizer

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION Document No.:JSS144.2016 Revision:A0 PRODUCT SPECIFICATION ALKALINE AAA SIZE BATTERY Type Designation : LR03UP/AAA Prepared by : Checked by : Approved by : Issued Date : 2016-04-03 Zhongyin (Ningbo) Battery

More information

Fertilizers and nutrient management for hops. Diane Brown, Michigan State University Extension

Fertilizers and nutrient management for hops. Diane Brown, Michigan State University Extension Fertilizers and nutrient management for hops Diane Brown, Michigan State University Extension Pre plant nutrient management for hops Soil test! Correct major issues before planting ph 6.2 to 6.5 Lime season

More information

E1000 Portable gas detector

E1000 Portable gas detector E1000 Portable gas detector Operation manual Ver:HWWM161229CG Read this manual carefully before using the device Table of Contents SAFETY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION

More information

Portable Instrument Application Guide

Portable Instrument Application Guide Portable Instrument Application Guide Which Portable Gas Detector for which Industry/Application Because every life has a purpose... Gas Detection Instruments Advanced Technology Advanced technology employed

More information

gas monitoring system

gas monitoring system www..com gas monitoring system Photon S is s most recent and most sophisticated apparatus. It was created based on portable gas analyser - Photon. As its sucessor it also uses gas sensors as the main measurement

More information

IMR EX610. Portable Gas Detector. Operation Manual

IMR EX610. Portable Gas Detector. Operation Manual IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before

More information

Soil. Acidic soils... 1/19/2014

Soil. Acidic soils... 1/19/2014 Soil Chapter 8 Acidic Soils & Salt Affected Soils Pages 229 262 About 2.5 billion acres of mostly cultivated lands are affected by soil salinity Treating ph problems is less difficult than managing and

More information

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Gas Detection. - Disposable - Serviceable. Single Gas Detectors Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight

More information

Class 3: Soil Sampling and Testing. Chris Thoreau

Class 3: Soil Sampling and Testing. Chris Thoreau Class 3: Soil Sampling and Testing Chris Thoreau What is Soil Testing? What are We Testing For? Soil Sampling Methodologies Soil Testing Interpreting Soil Test Results What is Soil Testing? Soil testing

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

Glenside Environmental Services Ltd

Glenside Environmental Services Ltd Unit 18 Great Island Industrial Park, Ballincollig, Co. Cork. Testing Laboratory Registration number: 322T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule

More information

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence

More information

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Catalytic Ex-Sensors DrägerSensors Dräger Catalytic Ex-Sensors DrägerSensors High product quality, low operational costs: Thanks to DrägerSensor CatEx PR technology, our sensors are resistant to poisoning and particularly stable over the

More information

Soil Management Site Selection, Soil Fertility. Warren Roberts George Kuepper

Soil Management Site Selection, Soil Fertility. Warren Roberts George Kuepper Soil Management Site Selection, Soil Fertility Warren Roberts George Kuepper Where We re Going Soil Texture and Drainage Site Selection Soil Fertility & ph Fertilizers & Nutrients Later Sessions Soil Biology

More information

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66. Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed

More information

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler Service instructions for contractors VIESMANN Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler For applicability, see the last page VITORONDENS 200-T 6/2011 Please keep safe. Safety

More information

Instruction and Maintenance Manual. Spiral Heat Exchanger

Instruction and Maintenance Manual. Spiral Heat Exchanger Instruction and Maintenance Manual Spiral Heat Exchanger 1. Content Description... Section 2 Introduction... Section 3 Important safety Precautions... Section 4 Generally... Section 5 Correct Installation...

More information

Understanding Your Virginia Soil Test Report

Understanding Your Virginia Soil Test Report Understanding Your Virginia Soil Test Report By Gil Medeiros, Fairfax Master Gardener Don t guess; soil test! As master gardeners, we frequently exhort gardeners to do the test, but we are not so helpful

More information

Complex Solid Waste Air Permitting Issues

Complex Solid Waste Air Permitting Issues Complex Solid Waste Air Permitting Issues A Threat to Landfill Gas as an Alternative Fuel Source Heather H. Little Sanborn, Head and Associates, Inc. John Gay, E.I. Casella Waste Systems, Inc. NEWSVT Landfill

More information

Nutrient Management of Irrigated Alfalfa and Timothy

Nutrient Management of Irrigated Alfalfa and Timothy Nutrient Management of Irrigated Alfalfa and Timothy Irrigated Crop Production Conf. Lethbridge, AB Jan 19, 2016 Ross H. McKenzie Old Agronomist Lethbridge Introduction Alfalfa and Timothy are excellent

More information

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE CLARIFICATION ON TENDER NUMBER - IISER-PUR-0284-17 ITEM DESCRIPTION- PROCUREMENT OF GRAPHITE-FURNACE ATOMIC ABSORPTION SPECTROMETER WITH CHNS/O ANALYZER

More information

Treatment of Digester Gas

Treatment of Digester Gas Treatment of Digester Gas Tom Mossinger, PE SCAP Energy Management Committee Meeting February 28, 2013 Digester Gas Composition Approximately 60% CO 2 Approximately 40% CH 4 Water vapor saturated at 95-100

More information

What s in Your Media? Analysis of media components for micronutrient content

What s in Your Media? Analysis of media components for micronutrient content What s in Your Media? Analysis of media components for micronutrient content Internal Report for Young Plant Research Center Partners. Not for publication in part or full without permission of authors.

More information

Dräger X-am 2500 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection Dräger X-am 2500 Multi-Gas Detection The Dräger X-am 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2,

More information

Thermo Scientific TVA2020 Introduction

Thermo Scientific TVA2020 Introduction Thermo Scientific TVA2020 Introduction The Thermo ScientificT TVA2020 Toxic Vapor Analyzer, is an advanced design, portable, organic/inorganic vapor monitor for the gas survey industry. The analyzer uses

More information

A Plant & Soil Ecosystem

A Plant & Soil Ecosystem Introductory Study of Soils For the Master Gardeners Wendy Sue Harper, Ph.D. What We Will Cover Tonight Introduction Agroecological perspective to understanding the physical, chemical and biological properties

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE Portable Ammonia Leak Detector QUICK REFERENCE GUIDE Specially configured GasAlert Micro 5 PID from Refer to for more details. Manual provided on CD with unit at time of purchase 2 Table of Contents Getting

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head Office Koolwaterststraat 1 6161 RA Geleen The Netherlands Location Abbreviation/ location code Koolwaterststraat 1 6161 RA Geleen The

More information

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN ) Page 1 of 7 All tests and sampling performed by the laboratory meet the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009. The Laboratory is qualified to update standards

More information

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles 1, 2, 3, 4, and 5 Gas Detectors Quick Reference Guide Limited Warranty & Limitation of Liability BW Technologies Ltd.

More information

Monitores Personales. Personal Monitor

Monitores Personales. Personal Monitor Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,

More information

General safety precautions English

General safety precautions English English 1 1 1.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow

More information

GASBLASTER LSX4 OPERATION MANUAL

GASBLASTER LSX4 OPERATION MANUAL GASBLASTER LSX4 OPERATION MANUAL 2 The treatment and transfer of wastewater produces odor emissions what are sometimes disturbing for the population living nearby a waste treatment facility or pumping

More information

High Carbon Wood Fly Ash as a Biochar Soil Amendment

High Carbon Wood Fly Ash as a Biochar Soil Amendment High Carbon Wood Fly Ash as a Biochar Soil Amendment Preliminary Assessment Completed by Northern Tilth June 2010 Executive Summary Resource Management, Inc. (RMI) recycles wood ash from biomass plants

More information

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection Procedure No: SOP-020 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to

More information

Plant Nutrition & Fertilizers WMAMG 1/31/17

Plant Nutrition & Fertilizers WMAMG 1/31/17 Plant Nutrition & Fertilizers WMAMG 1/31/17 By Dawn Pettinelli UConn Soil Nutrient Analysis Lab dawn.pettinelli@uconn.edu SOIL-PLANT SYSTEM From: Extension.org Relationships between plants & soils evolved

More information

The Cameron Clean Room

The Cameron Clean Room The Cameron Clean Room Clean Room Teams Will Start This Week How to get to Cameron Hall Shuttle Stop CAMERON HALL Second floor entrance Main entrance CAMERON Best entrance to the clean room second floor

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

Table 4. Nutrient uptake and removal by sunflower in Manitoba studies. Nutrient Uptake Removal Uptake Removal

Table 4. Nutrient uptake and removal by sunflower in Manitoba studies. Nutrient Uptake Removal Uptake Removal SUNFLOWER FERTILITY Ensuring the fertility needs of the crop are met is critical to maximize yield and profit. Fertilizer applications should be made based on a soil test, to prevent improper application

More information

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended

More information

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions Microtector II G460 7-gas-detector with performance test approval Performance test approved multi-gas detector (290g) Extremely loud alarm, 103 db(a) for optimum personnel protection Full featured, rugged

More information

GAS DETECTION International Gas Detectors CH4 NO

GAS DETECTION International Gas Detectors CH4 NO GAS DETECTION HSCO SOCO GAS DETECTORS FOR INDUSTRIAL ENVIRONMENTS TOCSIN 150 SERIES ADDRESSABLE GAS SAMPLERS Quality Assured HSCO SOCO In many applications in industry requiring gas detection it is often

More information

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information 100.90.02 ATEX Certified Vacuum Pumps Oerlikon Leybold Vacuum offers a selection of different types of vacuum

More information

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle. Refrigeration Cycle Reading Problems 10-1 10-5, 10-7, 10-9 10-11, 10-14, 10-39 Definitions a refrigeration system removes thermal energy from a low-temperature region and transfers heat to a high-temperature

More information

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application. 300 Features Digital measurement value processing incl. temperature compensation Internal function control with integrated hardware watchdog Data / measured values sensor controller, therefore simple exchange

More information

BOILER SYSTEM CHEMICAL TREATMENT 101

BOILER SYSTEM CHEMICAL TREATMENT 101 BOILER SYSTEM CHEMICAL TREATMENT 101 The primary function of a boiler is to transfer heat from hot gases generated by the combustion of fuel into water until it becomes hot or turns to steam. The steam

More information

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions

Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions Reflex Longtherm Soldered plate-type heat exchanger 09-2016 EN Operating instructions English Refle x Longth erm Contents 09-2016 Contents 1 Safety... 3 1.1 Personnel requirements... 3 1.2 Instructions

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER GUIDE SPECIFICATIONS 150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER HEATER 1. General Description The Contractor shall furnish and install (Qty) Yazaki model CH- Gas Fired,

More information

ODOUR GENERATION AND DUST IN BELT DRYING OF SEWAGE SLUDGE

ODOUR GENERATION AND DUST IN BELT DRYING OF SEWAGE SLUDGE ODOUR GENERATION AND DUST IN BELT DRYING OF SEWAGE SLUDGE Heindl A. HUBER SE, Waste Water Technology, Berching, Germany. www.huber.de Tel. 0049 / 8462 201 281 Email hal@huber.de Abstract Belt drying of

More information

Tobacco Fertilization. Andy Bailey

Tobacco Fertilization. Andy Bailey Tobacco Fertilization Andy Bailey Plant nutrition 16 Essential Elements Non-mineral: Carbon, Hydrogen, Oxygen Macronutrients: Nitrogen, Potassium, Phosporous Needed in large amounts Deficiency common Secondary:

More information

Frequently Asked Questions

Frequently Asked Questions 1. 2. What advantages does the GT3000 have over the C7064? Hot swappable GTS sensor module is intrinsically safe and allows live maintenance under power Supports HART communication Supports local, one-person

More information

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications SAFETY MANUAL Intelligent Sensors for H 2 S Gas Applications The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the

More information

Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel

Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel Basic information about quick steam generators/boilers System GEKA Heat Technology Gottfried Kneifel 1. Definition The term quick steam generator or boiler is used in the TRD 001, point 4.4 (technical

More information

1.1 Definitions of alert icons. For your safety

1.1 Definitions of alert icons. For your safety For your safety 1 For your safety Before using this product, carefully read these Instructions for Use and those of the associated products. Strictly follow the Instructions for Use. The user must fully

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378 Lloyds Approval

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS TECHNICAL NOTE s for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS The DataFID and MicroFID II are portable flame ionization detectors designed to monitor volatile organic

More information

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Carbon Monoxide (CO) Gas Detector March 15 GCO 300 GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing

More information

Technical Data Sheet. Plus Blood & Bone Granules NPK

Technical Data Sheet. Plus Blood & Bone Granules NPK What is it? Yates AgriBoost Plus Blood & Bone is a granulated organic blend consisting of composted poultry manure and added blood & bone. The granulated formulation makes uniform spreading easier and

More information

Soils and Fertilizers Chapter 2. Sherry Kern Virginia Beach Master Gardener Tree Steward

Soils and Fertilizers Chapter 2. Sherry Kern Virginia Beach Master Gardener Tree Steward Soils and Fertilizers Chapter 2 Sherry Kern Virginia Beach Master Gardener Tree Steward Soil It s Not Dirt! outer, weathered superficial layer of the earth s crust physical, chemical, and biological factors

More information

2 OZONFILT And Bono Zon Ozone Plants

2 OZONFILT And Bono Zon Ozone Plants 2.4 OZONFILT OZMa P_PMA_OF_0010_SW Ozone plants of the type series OZONFILT OZMa are pressure systems which generate ozone using compressed air or oxygen under medium-frequency high voltage. The electronic

More information